Download York E4TS030 User's Manual
Transcript
036-21342-002 Rev. E (0505) ® DESCRIPTION The ETS Stealth series heat pump units use Twin Single™ compressor technology to provide cooling efficiencies up to 15.7 SEER and heating efficiencies up to 9.3 HSPF. They are to be installed with the matching variable speed Enhancer air handler or Diamond furnace, a corresponding coil and sweat connect lines. A factory specified balanced port hard shut-off TXV kit must be used for proper installation and optimum performance. WARRANTY TECHNICAL GUIDE 5-year limited parts warranty. 10-year limited compressor warranty. FEATURES STEALTH SPLIT-SYSTEM HEAT PUMP 15 SEER MODELS: E4TS030 THRU 060 (2.5 THRU 5 NOMINAL TONS) RT I FI ED T O ARI A S C O NI PUM P G UN I T T EA AR Y H Y MA N U F A CT U R PL ER M E C R IF IC AT AR E CT F U I P ME N T O EQ E C RT IO NS 40 I S ION S T A NDA R D 2 CERTIFICATION APPLIES ONLY WHEN THE COMPLETE SYSTEM IS LISTED WITH ARI. LISTED ISO 9001 Certified Quality Management System Due to continuous product improvement, specific tions are subject to change without notice. Visit us on the web at www.york.com for the most up-to-date technical information. Additional rating information can be found at www.ariprimenet.org. QUALITY CONDENSER COILS - The coil is constructed of copper tube and hardened aluminum fins for durability and long lasting efficient operation. The fins on the unit are protected with a decorative grille. DURABLE FINISH - Cabinet is made of powder painted steel over pre-painted primer. The pre-treated flat galvanized steel provides a better paint to steel bond, which resists corrosion and rust creep. Special primer formulas and glossy earth tone finish insure less fading when exposed to sunlight. This finish has been tested to provide 1/3 greater protection than conventional units. PROTECTED COMPRESSORS - The Twin Single™ compressor is protected against high pressure. Hard start components are included to ensure start-up under adverse conditions. All models have standard crankcase heat for added protection. OPTIMUM PERFORMANCE - The solid-state electronic controlboard optimizes the compressor staging based on load requirements, provides a 5-minute anti-short cycle timer, and simplifies troubleshooting with built in self diagnostics. LOWER INSTALLED COST - Installation time and costs are reduced by easy power and control wiring connections. All units contain enough refrigerant for the smallest matching indoor coil and 15 feet of interconnecting piping. The small base dimension means less space is required on the ground or roof. EFFECTIVE HUMIDITY CONTROL - The inherent design of the Stealth system and the staging operation of the Twin Single™ compressor provide effective humidity control at the lowest possible operating cost. An optional dehumidification control accessory is available to maintain the humidity at a set desired level. TOP DISCHARGE - The warm air from the top mounted fan is blown up away from the structure and any landscaping. This allows compact location on multi-unit applications. LOW OPERATING SOUND LEVEL - The upward air flow carries the normal operating noise up away from the living area. The rigid top panel effectively isolates any motor sound. Isolator mounted compressor and the rippled fins of the condenser coil muffle the normal fan motor and compressor operating sounds. LOW MAINTENANCE - Long life permanently lubricated motor- bearings need no annual servicing. EASY SERVICE ACCESS - Fully exposed refrigerant connections and a single panel covering the electrical controls make servicing easy. Easy access for coil clearing is also provided. RE-USABLE SERVICE VALVES - Provided on both the liquid and vapor sweat connections for ease of evacuating and charging. FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE 036-21342-002 Rev. E (0505) SYSTEM OPERATION 4. This heat pump model is equipped with both YorkGuard V heat pump control and TS compressor control. The interface control 6CF board is used to bypass the first stage of heat when the outdoor temperature falls below certain temperatures. The TS control board is used only to switch between 1 and 2 cylinder operation. The fault codes and pressure switch on the TS control board are bypassed using the jumpers between the test and "PS" pins. 1. 2. 3. Anti-short Cycle Timer The five-minute time delay on YorkGuard V will be used to prevent the system from short cycling after the thermostat off or power interrupt. This time delay can be bypassed by temporarily shorting the test terminals on YorkGuard V for 3 seconds. Since a jumper was factory installed across the test pins on the TS control board, the anti-short cycle timer on the TS control board is bypassed. First Stage Cooling This heat pump model is equipped with a Twin-Single compressor. With a call for first stage cooling, the compressor operates one cylinder. The run winding (R) is connected through the upper left contactor (A) and to the capacitor and the start winding (S) is connected to line voltage. The system operates at low discharge pressure and high suction pressure. Second Stage of Cooling With a call for second stage cooling, the TS control will shut the compressor off for two seconds then energize relays R1 and R2 on the TS control board. This will deenergize (open) the upper left contactor (A) and energize (close) the lower right contactor (B), connecting the compressor run winding (R) to the line voltage and start winding (S) to the capacitor. The compressor runs in the reverse direction with two cylinders compared to the first stage. The system will operate with two cylinders until both first and second stage are satisfied. The Y2OUT signal from the relay board causes the indoor blower to function at high speed. 6K Relay on the 6CF Control Board The 6K relay on the 6CF interface board operates as follows. See Figure 1: a. If the YorkGuard V defrost control balance point setting is 45°F, the 6K relay will be: • Energized if liquid temperature goes below 35°F. • De-energized if the liquid temperature goes above 35°F AND the ambient is greater than 42°F for five minutes AND the unit is not in defrost. b. If the YorkGuard V defrost control balance point setting is at anything but 45°F, the 6K relay will be: • Energized if liquid temperature goes below 45°F. • De-energized if the liquid temperature goes above 45°F AND the ambient is greater than 55°F AND the unit is not in defrost. 5. Heating mode with the de-energized 6K relay The TS compressor operates similar to the first and second stage of cooling modes except there is no O input from the thermostat, the reversing valve is not energized, and the system operates in heating heat pump mode. The YorkGuard V control and the liquid temperature will not allow the system to go into the defrost mode. 6. Heating mode with the energized 6K Relay The energized 6K relay on the interface board (6CF) will connect Y1 and Y2 and disconnect Y2OUT from the TS control to the indoor blower if the J1 pin is not in the ON position. The compressor will operate only in second stage regardless of the first or second stage call from the thermostat. The indoor blower will operate in low air mode. The indoor discharge air temperature should be about 10°F hotter than a normal heat pump. If highspeed air is preferred, move J1 pin to the ON position at the interface board (6CF). This will send the Y2OUT signal back to the indoor blower for the high speed air. Y2 If the room thermostat calls for second stage cooling (Y2) on two consecutive cooling cycles, the next call for cooling for either first or second stage will energize the unit in second stage mode. The above mode will be reset to permit start up on the first stage with only a Y1 call when the second stage operation cycle runs less than 15 minutes or when 24V to the TS control board is disconnected. Y2 OUT 6K 24V (R) FROM YORKGUARD 6K NC NC J1 6K NO R Y2 Y1 Y2 OUT FIGURE 1 : 6CF Interface Board 2 Unitary Products Group 036-21342-002 Rev. E (0505) Physical and Electrical Data MODEL E4TS030 E4TS036 UNIT SUPPLY VOLTAGE E4TS048 E4TS060 208/230-1-60 NORMAL VOLTAGE RANGE 1 187 to 252 MIN. CIRCUIT AMPACITY 14.8 2 34.4 25 30 50 60 T27B355CBCA T29A464BBCA T29A544BBCA RATED LOAD 11.3 14.1 21.2 26.3 LOCKED ROTOR 65 84 130 142 CRANKCASE HEATER FAN MOTOR AMPS YES YES YES YES RATED LOAD .7 .7 1.5 1.5 24 24 24 24 RATED HP 1/10 1/10 1/4 1/4 FAN DIAMETER INCHES FAN MOTOR 28.0 T27B264CBCA MAX. OVERCURRENT DEVICE AMPS COMPRESSOR TYPE COMPRESSOR AMPS 18.3 NOMINAL RPM 825 825 825 850 NOMINAL CFM 2650 2650 3200 3200 FACE AREA SQ. FT. 20.0 20.0 20.0 20.0 ROWS DEEP 1 1 2 2 COIL FIN / INCH LIQUID LINE OD VAPOR LINE OD 3 16 16 13 13 3/8 3/8 3/8 3/8 7/8 7/8 7/8 7/8 9-9 10 - 1 12 - 1 13 - 1 CHARGE PER FOOT, OZ .70 .70 .70 .70 OPERATING WEIGHT LBS. 242 242 310 310 UNIT CHARGE, (LBS - OZ) 1. Rated in accordance with ARI Standard 110, utilizaton range “A”. 2. Dual element fuses or HACR circuit breaker. 3. The Unit Charge is correct for the outdoor unit, matched indoor coil and 15 feet of refrigerant tubing. For tubing lengths other than 15 feet, add or subtract the amount of refrigerant calculated, using the difference in length multiplied by the per foot value. All dimensions are in inches. They are subject to change without notice. Certified dimensions will be provided upon request. 48" OVERHEAD CLEARANCE C B UNIT MODEL E4TS AIR IN 4 SIDES A 030 036 048 060 REFRIGERANT CONNECTION LINE SIZE DIMENSIONS A 31-7/8 31-7/8 31-7/8 37-7/8 B 35 35 35 35 C 35 35 35 35 LIQUID VAPOR 3/8 7/8 5-1/2 VAPOR CONNECTION 2-3/8 LIQUID CONNECTION 3-1/8 Unitary Products Group 3 036-21342-002 Rev. E (0505) Additional R-22 Charge / Orifice Size for Various Matched Systems OUTDOOR UNIT E4TS030 UNIT ORIFICE(S)** FACTORY CHARGE, LBS. - OZ. INDOOR COIL COIL ORIFICE1 E4TS036 E4TS048 E4TS060 — — — — 9-9 10 - 1 12 - 1 13 - 1 REQUIRED SYSTEM EXPANSION DEVICE + ADDITIONAL CHARGE, OZ. G1FA/G1UA048S17,21 78 701 + 0 702 + 0 — — G1FA/G1UA060S21,24 84 — 702 + 10 703 + 0 703 + 0 G1FA060S21,24T 84 — — 703 + 0 703 + 0 G2FD046(S,H)17 78 701 + 0 702 + 0 — — G2FD042(S,H)21 78 701 + 0 — — — G2FD048(S,H)21, 24 84 701 + 6 702 + 0 — — G2FD060(S,H)24 90 — 702 + 10 703 + 0 703 + 0 G2FD060H24T 90 — — 703 + 0 703 + 0 G2FD061H24 90 — — 703 + 8 703 + 4 .70 .70 .70 .70 — — — REFRIGERANT LINE ADDER OZ. / FT. Airflow VARIABLE SPEED INDOOR N1VSB12 Hi/Low CFM 1050/630 N1VSC16 Hi/Low CFM 1065/650 1185/770 — — N1VSD20 Hi/Low CFM — 1200/780 1605/1040 1860/1200 P1XDB12V075 Hi/Low CFM 1040/580 1220/690 — — P1XUB12V055 Hi/Low CFM 1020/570 1200/660 — — P1DUB16V080 Hi/Low CFM 1050/540 1200/650 — — P1XUC16V075 Hi/Low CFM 1000/550 1200/650 1605/880 — P1DUC20V080 Hi/Low CFM — 1220/660 1620/900 1870/1030 P1DUC20V096 Hi/Low CFM — 1200/650 1610/900 1850/1080 P1XUC20V095 Hi/Low CFM — 1200/630 1590/850 1880/1000 P1XUD20V112 Hi/Low CFM — 1260/720 1620/920 1800/990 P1XDD20V112 Hi/Low CFM — 1200/690 1610/850 1870/1010 F(2,3)FV060 Hi/Low CFM — — 1600/1040 1875/1200 Hi CFM — 1000 1200 1600 1900 Max Low CFM — 850 1000 1350 1600 Recommended Low CFM — 600 750 900 1050 1. Unit factory charge listed on the unit nameplate includes refrigerant for the condensor, the smallest evaporator and for 15 feet of interconnecting line tubing. 2. Verify the TXV kit and the additional charge required for the specific evaporator coil in the system using the table above. 3. Add additional charge for the amount of interconnecting line tubing greater than 15 feet at the rate specified in the table above. 4. Permanently mark the unit nameplate with the total system charge. 5. Total System Charge = Base charge (as shipped) + adder for evaporator + adder for line set. 4 Unitary Products Group 036-21342-002 Rev. E (0505) COOLING CAPACITY - Variable Speed Air Handler UNIT MODEL N1VS AIR HANDLER ELECTRIC MODEL HEAT KW 2 1 W N1VSB12 5,7.5,10,15,18 17 N1VSC16 5,7.5,10,15,20 21 COIL MODEL STAGE (# CYL) RATED CFM 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 630 1050 650 1065 650 1065 770 1185 780 1200 1040 1600 1040 1605 1040 1605 1220 1875 1200 1860 1200 1860 G2FD046S17 G2FD042S21 E4TS030 G2FD048S21 N1VSC16 5,7.5,10,15,20 21 G2FD048S21 N1VSD20 7.5,10,15,20,25,30 24 G2FD048S24 F(2,3)FV060 10,15,20,25 N1VSD20 7.5,10,15,20,25,30 E4TS036 – E4TS048 24 G2FD060S24 G2FD061H24 F(2,3)FV060 10,15,20,25 – N1VSD20 7.5,10,15,20,25,30 E4TS060 24 G2FD060S24 G2FD061H24 COOLING NET MBH SEER TOTAL SENS. 15200 29000 15000 28600 15800 30000 21400 36000 21600 36400 26800 48000 26800 48000 27400 49000 27800 55500 27800 55500 29000 57000 12200 21400 12000 21000 12600 22000 15400 25600 15600 26000 21800 35600 21800 35600 22200 36400 23400 40500 23400 40500 24000 41500 EER 13.7 12.0 13.6 11.9 13.9 12.1 13.3 11.6 13.6 11.8 13.6 11.4 13.6 11.4 13.8 11.6 13.2 10.4 13.2 10.4 13.4 10.6 15.5 15.4 15.7 15.0 15.2 15.0 15.0 15.2 14.5 14.5 14.7 1. G2FD coils available with a factory installed horizontal drain pan. See price pages for specific model number. 2. Single phase units require single phase 2HK heaters. COOLING CAPACITY - Variable Speed Furnace COOLING UNIT MODEL VARIABLE SPEED FURNACE MODEL W COIL MODEL P1XDB12V 17 G2FD046S17 G2FD046S17 P1XUB12V 17 G1UA048S17 G1FA048S17 G2FD046S17 E4TS030 P1DUB16V 17 G1UA048S17 G1FA048S17 G2FD042S21 G1UA048S21 P1XUC16V 21 G1FA048S21 G2FD048S21 STAGE (# CYL) RATED CFM 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 580 1040 570 1020 570 1020 570 1020 540 1050 540 1050 540 1050 600 1100 600 1100 600 1100 600 1100 NET MBH1 TOTAL SENS. 13800 28200 13800 28000 13800 28000 13800 28000 13600 28200 13600 28200 13600 28200 13600 28000 13800 28800 13800 28800 14200 29000 10400 20800 10400 20600 10400 20600 10400 20600 10200 20800 10200 20800 10200 20800 10400 20600 10600 21400 10600 21400 10800 21400 SEER2 EER3 13.3 11.6 13.3 11.6 13.3 11.6 13.3 11.6 13.4 11.7 13.4 11.7 13.4 11.7 13.2 11.4 13.6 11.6 13.6 11.6 13.7 11.8 15.0 15.0 15.0 15.0 15.0 15.0 15.0 14.8 15.2 15.2 15.3 For notes see Page 7. Unitary Products Group 5 036-21342-002 Rev. E (0505) COOLING CAPACITY - Variable Speed Furnace (Continued) COOLING UNIT MODEL VARIABLE SPEED FURNACE MODEL W COIL MODEL P1XDB12V 17 G2FD046S17 G2FD046S17 P1XUB12V 17 G1UA048S17 G1FA048S17 G2FD046S17 P1DUB16V 17 G1UA048S17 E4TS036 G1FA048S17 G1UA048S21 G1FA048S21 P1XUC16V 21 G2FD048S21 G1UA060S21 G1FA060S21 G1UA048S21 G1FA048S21 P1DUC20V 21 G2FD048S21 G1UA060S21 G1FA060S21 G1UA048S21 G1FA048S21 P1XUC20V 21 G2FD048S21 E4TS036 G1UA060S21 G1FA060S21 P1XDD20V 24 G2FD048S24 G1UA048S24 G1FA048S24 P1XUD20V 24 G2FD048S24 G1UA060S24 G1FA060S24 STAGE (# CYL) RATED CFM 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 690 1220 660 1200 660 1200 660 1200 650 1200 650 1200 650 1200 640 1200 640 1200 640 1200 640 1200 640 1200 640 1200 640 1200 640 1200 640 1200 640 1200 625 1200 625 1200 625 1200 625 1200 625 1200 690 1200 715 1260 715 1260 715 1260 715 1260 715 1260 NET MBH1 TOTAL SENS. 20000 35600 19800 35400 19800 35400 19800 35400 20000 35600 20000 35600 20000 35600 20200 35800 20200 35800 20400 36000 21000 37000 21000 37000 20200 35800 20200 35800 20400 36000 21000 37000 21000 37000 20000 35600 20000 35600 20200 35800 20800 36800 20800 36800 20400 36000 20600 36200 20600 36200 20800 36400 21400 37400 21400 37400 15200 25800 15000 25600 15000 25600 15000 25600 15000 25600 15000 25600 15000 25600 15200 25800 15200 25800 15400 26000 15800 26600 15800 26600 15200 25800 15200 25800 15400 26000 15800 26600 15800 26600 15000 25600 15000 25600 15200 25800 15600 26400 15600 26400 16200 27400 16000 27200 16000 27200 16200 27400 16600 28000 16600 28000 SEER2 14.0 14.0 14.0 14.0 14.0 14.0 14.0 14.0 14.0 14.0 14.4 14.4 14.1 14.1 14.3 14.6 14.6 14.0 14.0 14.2 14.5 14.5 14.5 14.2 14.2 14.5 14.8 14.8 For notes see Page 7. 6 Unitary Products Group EER3 12.4 10.8 12.5 11.0 12.5 11.0 12.5 11.0 12.6 11.0 12.6 11.0 12.6 11.0 12.5 11.1 12.5 11.1 12.6 11.1 13.0 11.3 13.0 11.3 12.5 11.2 12.5 11.2 12.8 11.3 13.1 11.4 13.1 11.4 12.6 11.0 12.6 11.0 12.7 11.2 13.0 11.3 13.0 11.3 12.9 11.3 12.8 11.2 12.8 11.2 13.0 11.4 13.3 11.6 13.3 11.6 036-21342-002 Rev. E (0505) COOLING CAPACITY - Variable Speed Furnace (Continued) COOLING UNIT MODEL VARIABLE SPEED FURNACE MODEL W COIL MODEL G1UA060S21 P1XUC16V 21 G1UA060S21 G1UA060S21 P1DUC20V 21 G1FA060S21 E4TS048 G1UA060S21 P1XUC20V 21 G1FA060S21 G2FD060S24 P1XDD20V 24 G2FD061H24 G1UA060S24 G1FA060S24 E4TS048 P1XUD20V 24 G2FD060S24 G2FD061H24 G2FD060S24 P1XDD20V 24 G2FD061H24 G1UA060S24 E4TS060 G1FA060S24 P1XUD20V 24 G2FD060S24 G2FD061H24 STAGE (# CYL) RATED CFM 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 880 1600 880 1600 900 1610 900 1610 850 1590 850 1590 880 1580 880 1580 915 1620 915 1620 915 1620 915 1620 1000 1800 1000 1800 990 1800 990 1800 990 1800 990 1800 NET MBH1 TOTAL SENS. 23800 47000 23800 47000 24200 47500 24200 47500 23600 47000 23600 47000 24400 47500 24800 48500 24800 48000 24800 48000 24800 48000 25200 49000 27000 55000 28000 56000 27000 55500 27000 55500 27000 55500 28000 56500 17600 33800 17600 33800 18000 34200 18000 34200 17400 33800 17400 33800 18400 34200 18800 34800 18800 34600 18800 34600 18800 34600 19200 35200 20400 39600 20800 40000 20400 40000 20400 40000 20400 40000 20800 40500 SEER2 EER3 12.6 10.8 12.6 10.8 12.6 10.9 12.6 10.9 12.6 10.8 12.6 10.8 12.5 11.0 12.7 11.2 12.7 11.0 12.7 11.0 12.7 11.0 12.9 11.3 12.6 10.0 12.8 10.2 12.5 10.2 12.5 10.2 12.5 10.2 12.8 10.4 14.0 14.0 14.0 14.0 14.0 14.0 14.0 14.4 14.2 14.2 14.2 14.5 13.7 14.0 13.8 13.8 13.8 14.0 1. Cooling MBH based on 80° F entering air temperature, 50% RH and rated airflow. 2. SEER (Seasonal Energy Efficiency Ratio) equals the total cooling output in BTU’s during a normal annual usage period for cooling divided by the total electric power input in watt-hours during the same period. Normal annual usage is a combination of both one and two cylinder operating periods. 3. EER (Energy Efficiency Ratio) equals the total cooling output in BTU’s at 95° F outdoor ambient divided by the total electric power in watt-hours at those conditions. Unitary Products Group 7 036-21342-002 Rev. E (0505) HEATING CAPACITY - Variable Speed Air Handler UNIT MODEL N1VS AIR HANDLER ELECTRIC MODEL HEAT KW 2 W N1VSB12 5,7.5,10,15,18 17 N1VSC16 5,7.5,10,15,20 21 E4TS030 COIL MODEL1 STAGE (# CYL) G2FD046S17 G2FD042S21 G2FD048S21 N1VSC16 5,7.5,10,15,20 21 G2FD048S21 N1VSD20 7.5,10,15,20,25,30 24 G2FD048S24 F(2,3)FV060 10,15,20,25 E4TS036 E4TS048 – 24 N1VSD20 G2FD060S24 7.5,10,15,20,25,30 G2FD061H24 F(2,3)FV060 10,15,20,25 N1VSD20 7.5,10,15,20,25,30 E4TS060 – 24 G2FD060S24 G2FD061H24 1 2 2 1 2 2 1 2 2 1 2 2 1 2 2 1 2 2 1 2 2 1 2 2 1 2 2 1 2 2 1 2 2 RATED CFM 630 630 1050 650 650 1065 650 650 1065 770 770 1185 780 780 1200 1040 1040 1600 1040 1040 1605 1040 1040 1605 1220 1220 1875 1200 1200 1860 1200 1200 1860 HEATING NET MBH 47 OD 17 OD 13400 24600 26400 13200 24200 26000 13800 24800 27000 19600 31600 35000 20000 32000 35600 23800 43500 47000 23800 43500 47000 24200 44500 48000 25800 51000 54000 25800 51000 54000 26600 50500 55000 – 14400 15400 – 14200 15200 – 14800 16000 – 19000 20800 – 19200 21200 – 24800 26400 – 24800 26400 – 25600 27000 – 26400 28600 – 26400 28600 – 26800 29200 HSPF COP@ 47 – 8.7 9.0 – 8.7 9.0 – 8.9 9.2 – 8.7 9.2 – 8.8 9.3 – 8.2 8.5 – 8.2 8.5 8.4 8.7 – 8.1 8.5 – 8.1 8.5 – 8.3 8.7 1. G2FD coils available with a factory installed horizontal drain pan. See price pages for specific model number. 2. Single phase units require single phase 2HK heaters. 8 Unitary Products Group 3.80 3.48 3.60 3.80 3.46 3.58 3.88 3.52 3.64 3.78 3.52 3.54 3.86 3.62 3.74 3.66 3.50 3.58 3.66 3.50 3.58 3.72 3.58 3.66 3.58 3.32 3.44 3.58 3.32 3.44 3.64 3.38 3.50 036-21342-002 Rev. E (0505) HEATING CAPACITY - Variable Speed Furnace HEATING UNIT MODEL VARIABLE SPEED FURNACE MODEL W COIL MODEL P1XDB12V075 17 G2FD046S17 G2FD046S17 P1XUB12V055 17 G1UA048S17 G1FA048S17 G2FD046S17 E4TS030 P1DUB16V080 17 G1UA048S17 G1FA048S17 G2FD042S21 G1UA048S21 P1XUC16V075 21 G1FA048S21 G2FD048S21 P1XDB12V075 17 G2FD046S17 17 G2FD046S17 E4TS036 P1XUB12V055 G1UA048S17 G1FA048S17 STAGE RATED (# CYL) CFM 1 2 2 1 2 2 1 2 2 1 2 2 1 2 2 1 2 2 1 2 2 1 2 2 1 2 2 1 2 2 1 2 2 1 2 2 1 2 2 1 2 2 1 2 2 580 580 1040 570 570 1020 570 570 1020 570 570 1020 540 540 1050 540 540 1050 540 540 1050 600 600 1100 600 600 1100 600 600 1100 600 600 1100 690 690 1220 660 660 1200 660 660 1200 660 660 1200 NET MBH 1,2 47 OD 17 OD 12800 24000 26200 12800 23800 26000 12800 23800 26000 12800 23800 26000 12400 24200 26400 12400 24200 26400 12400 24200 26400 13000 24800 27000 13200 25200 27400 13200 25200 27400 13400 25400 27600 17400 31000 34600 17200 31000 34600 17400 31400 35000 17400 31400 35000 14000 15200 13800 15000 13800 15000 13800 15000 14200 15400 14200 15400 14200 15400 14600 15800 15000 16400 15000 16400 15200 16600 18400 20600 18400 20600 18400 20800 18600 20800 HSPF3 COP4 @ 47 F 8.3 8.6 8.3 8.6 8.3 8.6 8.3 8.6 8.3 8.6 8.3 8.6 8.3 8.6 8.4 8.7 8.5 8.8 8.5 8.8 8.6 8.9 7.9 8.3 8.0 8.4 8.0 8.4 8.0 8.4 3.58 3.38 3.56 3.58 3.34 3.52 3.58 3.34 3.52 3.58 3.34 3.52 3.54 3.39 3.58 3.54 3.39 3.58 3.54 3.39 3.58 3.70 3.46 3.64 3.72 3.50 3.68 3.72 3.50 3.68 3.76 3.50 3.68 3.56 3.26 3.52 3.54 3.30 3.56 3.58 3.32 3.58 3.58 3.32 3.58 For notes see Page 12. Unitary Products Group 9 036-21342-002 Rev. E (0505) HEATING CAPACITY - Variable Speed Furnace (Continued) HEATING UNIT MODEL VARIABLE SPEED FURNACE MODEL W COIL MODEL G2FD046S17 P1DUB16V080 17 G1UA048S17 G1FA048S17 G1UA048S21 G1FA048S21 P1XUC16V075 21 G2FD048S21 G1UA060S21 G1FA060S21 G1UA048S21 E4TS036 G1FA048S21 P1DUC20V080 21 G2FD048S21 G1UA060S21 G1FA060S21 G1UA048S21 G1FA048S21 P1DUC20V096 21 G2FD048S21 G1UA060S21 G1FA060S21 STAGE RATED (# CYL) CFM 1 2 2 1 2 2 1 2 2 1 2 2 1 2 2 1 2 2 1 2 2 1 2 2 1 2 2 1 2 2 1 2 2 1 2 2 1 2 2 1 2 2 1 2 2 1 2 2 1 2 2 1 2 2 650 650 1200 650 650 1200 650 650 1200 640 640 1200 640 640 1200 640 640 1200 640 640 1200 640 640 1200 650 650 1220 650 650 1220 650 650 1220 650 650 1220 650 650 1220 640 640 1200 640 640 1200 640 640 1200 640 640 1200 640 640 1200 NET MBH 1,2 47 OD 17 OD 17000 31000 34600 17200 31400 35000 17200 31400 35000 17000 31600 35200 17000 31600 35200 17200 32000 35600 17600 32400 36000 17600 32400 36000 17200 32400 36000 17200 32400 36000 17400 32600 36200 18000 33000 36600 18000 33000 36600 17000 31800 35400 17000 31800 35400 17200 32000 35600 17600 32600 36200 17600 32600 36200 18400 20600 18600 20800 18600 20800 18800 21000 18800 21000 19000 21200 19400 21600 19400 21600 19000 21200 19000 21200 19400 21600 19800 22000 19800 22000 18800 21000 18800 21000 19000 21200 19400 21600 19400 21600 HSPF3 COP4 @ 47 F 8.0 8.4 8.0 8.4 8.0 8.4 8.0 8.4 8.0 8.4 8.1 8.5 8.4 8.7 8.4 8.7 8.1 8.5 8.1 8.5 8.2 8.6 8.5 8.8 8.5 8.8 8.0 8.4 8.0 8.4 8.1 8.5 8.4 8.7 8.4 8.7 For notes see Page 12. 10 Unitary Products Group 3.54 3.30 3.56 3.58 3.32 3.58 3.58 3.32 3.58 3.54 3.36 3.62 3.54 3.36 3.62 3.56 3.40 3.66 3.60 3.48 3.74 3.60 3.48 3.74 3.52 3.44 3.70 3.52 3.44 3.70 3.54 3.48 3.74 3.60 3.52 3.78 3.60 3.52 3.78 3.54 3.36 3.62 3.54 3.36 3.62 3.56 3.40 3.66 3.60 3.48 3.74 3.60 3.48 3.74 036-21342-002 Rev. E (0505) HEATING CAPACITY - Variable Speed Furnace (Continued) HEATING UNIT MODEL VARIABLE SPEED FURNACE MODEL W COIL MODEL G1UA048S21 G1FA048S21 P1XUC20V095 21 G2FD048S21 G1UA060S21 G1FA060S21 E4TS036 P1XDD20V112 G2FD048S24 G1UA048S24 G1FA048S24 P1XUD20V112 24 G2FD048S24 G1UA060S24 G1FA060S24 G1UA060S21 P1XUC16V075 21 G1FA060S21 G1UA060S21 P1DUC20V080 21 G1FA060S21 E4TS048 G1UA060S21 P1DUC20V096 21 G1FA060S21 G1UA060S21 P1XUC20V095 21 G1FA060S21 STAGE RATED (# CYL) CFM 1 2 2 1 2 2 1 2 2 1 2 2 1 2 2 1 2 2 1 2 2 1 2 2 1 2 2 1 2 2 1 2 2 1 2 2 1 2 2 1 2 2 1 2 2 1 2 2 1 2 2 1 2 2 1 2 2 625 625 1200 625 625 1200 625 625 1200 625 625 1200 625 625 1200 690 690 1200 715 715 1260 715 715 1260 715 715 1260 715 715 1260 715 715 1260 880 880 1600 880 880 1600 890 890 1620 890 890 1620 900 900 1610 900 900 1610 850 850 1590 850 850 1590 NET MBH 1,2 47 OD 17 OD 16600 31800 35400 16600 31800 35400 16800 32000 35600 17200 32600 36200 17200 32600 36200 18000 32000 35600 18000 32600 36200 18000 32600 36200 18200 32800 36400 18800 33400 37000 18800 33400 37000 20800 43500 47000 20800 43500 47000 21000 43500 47000 21000 43500 47000 21400 43500 47000 21400 43500 47000 20200 43000 46500 20200 43000 46500 18800 21000 18800 21000 19000 21200 19400 21600 19400 21600 19000 21200 19600 21800 19600 21800 19800 22000 20200 22400 20200 22400 24200 26200 24200 26200 24400 26400 24400 26400 24200 26200 24200 26200 23800 25800 23800 25800 HSPF3 COP4 @ 47 F 7.9 8.3 7.9 8.3 8.0 8.4 8.3 8.6 8.3 8.6 8.4 8.7 8.3 8.7 8.3 8.7 8.4 8.8 8.7 9.0 8.7 9.0 7.7 8.0 7.7 8.0 7.8 8.1 7.8 8.1 7.8 8.1 7.8 8.1 7.6 7.9 7.6 7.9 3.48 3.34 3.60 3.48 3.34 3.60 3.52 3.38 3.64 3.58 3.44 3.70 3.58 3.44 3.70 3.56 3.54 3.80 3.52 3.54 3.80 3.52 3.54 3.80 3.56 3.56 3.82 3.64 3.64 3.90 3.64 3.64 3.90 3.24 3.36 3.54 3.24 3.36 3.54 3.28 3.44 3.62 3.28 3.44 3.62 3.32 3.42 3.60 3.32 3.42 3.60 3.20 3.36 3.54 3.20 3.36 3.54 For notes see Page 12. Unitary Products Group 11 036-21342-002 Rev. E (0505) HEATING CAPACITY - Variable Speed Furnace (Continued) HEATING UNIT MODEL VARIABLE SPEED FURNACE MODEL W COIL MODEL G2FD060S24 P1XDD20V112 G2FD061H24 G1UA060S24 E4TS048 G1FA060S24 P1XUD20V112 24 G2FD060S24 G2FD061H24 G2FD060S24 P1XDD20V112 G2FD061H24 G1UA060S24 E4TS060 G1FA060S24 P1XUD20V112 24 G2FD060S24 G2FD061H24 STAGE RATED (# CYL) CFM 1 2 2 1 2 2 1 2 2 1 2 2 1 2 2 1 2 2 1 2 2 1 2 2 1 2 2 1 2 2 1 2 2 1 2 2 880 880 1580 880 880 1580 915 915 1620 915 915 1620 915 915 1620 915 915 1620 1000 1000 1800 1000 1000 1800 990 990 1800 990 990 1800 990 990 1800 990 990 1800 NET MBH 1,2 47 OD 17 OD 21400 43000 46500 22000 44000 47500 22200 44000 47500 22200 44000 47500 22200 44000 47500 22600 45000 48500 23400 49500 54000 23400 50500 55000 23200 49500 54000 23200 49500 54000 23200 49500 54000 23200 50500 55000 23800 25800 24400 26400 25000 27000 25000 27000 25000 27000 25600 27600 26000 28400 26600 29000 26000 28400 26000 28400 26000 28400 26600 29000 HSPF3 COP4 @ 47 F 7.7 8.0 7.9 8.2 7.8 8.1 7.8 8.1 7.8 8.1 8.0 8.3 7.5 7.9 7.9 8.2 7.6 8.0 7.6 8.0 7.6 8.0 8.0 8.3 3.30 3.34 3.52 3.38 3.42 3.60 3.34 3.36 3.54 3.34 3.36 3.54 3.34 3.36 3.54 3.40 3.44 3.62 3.38 3.28 3.46 3.48 3.35 3.52 3.34 3.34 3.52 3.34 3.34 3.52 3.34 3.34 3.52 3.42 3.40 3.58 1. Heating MBH based on ARI standards of 70° DB entering indoor air, 72% RH outdoor air with 25 feet of interconnecting piping and no supplemental electric heat operation. 2. Integrated heating capacities include the effect of defrost cycles in the temperature range where they occur. 3. HSPF (Heating Seasonal Performance Factor) is the total heating output during a normal annual usage period for heating divided by the total electric power input during the same period. 4. COP equals MBH output divided by (total KW input x 3.412). ACCESSORIES Refer to Price Manual for specific model numbers. TXV Kit - Factory specified and required for proper unit performance. E4TS030 = 1TV0701 E4TS036 = 1TV0702 E4TS048 = 1TV0703 E4TS060 = 1TV0703 Room Thermostat - Matching 2-Stage cooling thermostats are available to provide features required for any installation. See list below: 2ET03700624 - Honeywell Programmable 2ET03700524 - Honeywell Non-Programmable 2EP32U70124 - White Rodgers Programmable 12 Dehumidification Control - Model 2HU06700124 available for use in areas where a higher level of humidity control is required. Fossil Fuel Relay (Model 2FF02700101) - Required for use with all furnace applications. SOUND RATINGS* SOUND RATINGS (dba) UNIT MODEL 1 CYLINDER 2 CYLINDER 030 72 73 036 75 78 048 77 79 060 79 81 * Rated in accordance with ARI 270-95 Standards. Unitary Products Group 036-21342-002 Rev. E (0505) COOLING PERFORMANCE DATA E4TS030S06A WITH N1VSC1606 / G2FD048S21 - HIGH CFM 2-CYLINDER OPERATION ID CFM CONDENSER ENTERING AIR ID DB (°F) TEMPERATURE ID WB (°F) T.C. 75 S.C. K.W. T.C. 85 S.C. K.W. T.C. 95 S.C. K.W. T.C. 105 S.C. K.W. T.C. 115 S.C. K.W. T.C. 125 S.C. K.W. 80 72 35.72 16.87 2.13 33.76 16.34 2.32 31.81 15.81 2.51 29.85 15.28 2.70 27.96 14.77 2.88 26.06 14.25 3.06 80 67 32.39 21.50 2.11 30.76 21.18 2.27 29.13 20.86 2.43 27.50 20.53 2.59 25.92 20.22 2.75 24.33 19.90 2.90 980 80 62 29.01 26.90 2.07 27.81 26.05 2.21 26.61 25.21 2.36 25.40 24.36 2.51 24.24 23.53 2.65 23.07 22.71 2.79 75 62 29.01 21.61 2.07 27.81 20.76 2.21 26.61 19.91 2.36 25.40 19.06 2.51 24.24 18.24 2.65 23.07 17.41 2.79 80 57 27.74 26.84 2.00 27.15 25.72 2.17 25.99 24.61 2.32 24.27 23.49 2.45 23.58 22.41 2.60 22.40 21.32 2.77 80 72 36.45 17.73 2.19 34.33 17.09 2.38 32.20 16.46 2.56 30.08 15.82 2.74 28.02 15.20 2.92 25.96 14.58 3.09 80 67 33.78 23.46 2.19 31.89 22.72 2.34 30.00 22.22 2.49 28.11 21.61 2.64 26.27 21.00 2.79 24.43 20.40 2.94 1065 80 62 30.89 29.75 2.12 29.38 28.08 2.27 27.87 27.01 2.42 26.37 25.64 2.57 24.90 24.31 2.72 23.43 22.98 2.86 75 62 30.89 24.46 2.12 29.38 22.84 2.27 27.87 21.72 2.42 26.37 20.35 2.57 24.90 19.02 2.72 23.43 17.69 2.86 80 57 28.07 27.62 2.01 28.08 27.37 2.21 27.06 26.37 2.38 25.00 24.61 2.51 24.03 23.44 2.68 22.90 22.37 2.85 80 72 37.18 18.59 2.26 34.89 17.84 2.44 32.60 17.10 2.61 30.31 16.36 2.78 28.09 15.63 2.95 25.86 14.91 3.12 80 67 35.17 25.42 2.26 33.02 24.26 2.40 30.87 23.59 2.55 28.71 22.68 2.69 26.62 21.79 2.83 24.53 20.90 2.97 1210 80 62 32.78 32.61 2.17 30.96 30.10 2.33 29.14 28.82 2.48 27.33 26.93 2.63 25.56 25.09 2.78 23.80 23.26 2.93 75 62 32.78 27.31 2.17 30.96 24.91 2.33 29.14 23.53 2.48 27.33 21.64 2.63 25.56 19.80 2.78 23.80 17.97 2.93 80 57 28.39 28.39 2.01 29.01 29.01 2.24 28.13 28.13 2.43 25.73 25.73 2.57 24.47 24.47 2.76 23.41 23.41 2.92 80 72 19.90 10.13 1.02 18.83 9.90 1.10 17.75 9.68 1.20 80 67 18.81 13.95 1.01 17.65 13.22 1.08 16.48 12.49 1.19 770 80 62 18.17 15.46 0.99 17.12 14.62 1.07 16.06 13.79 1.17 75 62 18.17 10.54 0.99 17.12 9.71 1.07 16.06 8.87 1.17 80 57 17.98 17.98 0.98 16.84 16.84 1.06 15.97 15.97 1.15 E4TS030S06A WITH N1VSC1606 / G2FD048S21 - LOW CFM 1-CYLINDER OPERATION ID CFM 650 720 CONDENSER 80 80 80 75 80 80 80 80 75 80 ENTERING AIR ID DB (°F) TEMPERATURE ID WB (°F) 72 67 62 62 57 72 67 62 62 57 T.C. 19.20 18.62 17.94 17.94 17.75 19.55 18.71 18.06 18.06 17.86 75 S.C. 9.57 13.15 15.71 10.79 17.10 9.85 13.55 15.58 10.66 17.54 K.W. 0.99 0.98 0.97 0.97 0.95 1.01 0.99 0.98 0.98 0.96 T.C. 18.20 17.39 16.87 16.87 16.60 18.52 17.52 16.99 16.99 16.72 85 S.C. 9.28 12.73 14.29 9.38 16.13 9.59 12.98 14.46 9.54 16.49 K.W. 1.07 1.06 1.05 1.05 1.03 1.09 1.07 1.06 1.06 1.05 T.C. 17.20 16.16 15.80 15.80 15.45 17.48 16.32 15.93 15.93 15.71 95 S.C. 9.00 12.32 12.88 7.96 15.16 9.34 12.41 13.33 8.42 15.57 K.W. 1.16 1.15 1.14 1.14 1.12 1.18 1.17 1.15 1.15 1.14 Multipliers for determining the performance with other indoor sections. HIGH CFM LOW CFM Air Handler Coil T.C. S.C. KW Air Handler Coil T.C. S.C. KW N1VSB12 G2FD046S17 0.97 0.96 0.97 N1VSB12 G2FD046S17 0.94 0.99 0.96 N1VSC16 G2FD042S21 0.95 0.94 0.97 N1VSC16 G2FD042S21 0.93 0.97 0.96 Variable Speed Coil Furnace T.C. S.C. KW Variable Speed Coil Furnace T.C. S.C. KW P1XDB12V G2FD046S17 0.94 0.94 0.98 P1XDB12V G2FD046S17 0.85 0.84 0.90 P1XUB12V G2FD046S17 0.93 0.93 0.97 P1XUB12V G2FD046S17 0.85 0.84 0.90 P1XUB12V G1UA048S17 0.93 0.93 0.97 P1XUB12V G1UA048S17 0.85 0.84 0.90 P1XUB12V G1FA048S17 0.93 0.93 0.97 P1XUB12V G1FA048S17 0.85 0.84 0.90 P1DUB16V G2FD046S17 0.94 0.94 0.97 P1DUB16V G2FD046S17 0.84 0.83 0.88 P1DUB16V G1UA048S17 0.94 0.94 0.97 P1DUB16V G1UA048S17 0.84 0.83 0.88 P1DUB16V G1FA048S17 0.94 0.94 0.97 P1DUB16V G1FA048S17 0.84 0.83 0.88 P1DUC16V G2FD042S21 0.93 0.93 0.99 P1DUC16V G2FD042S21 0.84 0.84 0.90 P1DUC16V G1UA048S21 0.96 0.96 1.00 P1DUC16V G1UA048S21 0.85 0.84 0.88 P1DUC16V G1FA048S21 0.96 0.96 1.00 P1DUC16V G1FA048S21 0.85 0.86 0.88 P1DUC16V G2FD048S21 0.97 0.96 0.99 P1DUC16V G2FD048S21 0.88 0.88 0.90 NOTE: KW RATING IS FOR OUTDOOR AND INDOOR UNITS. Unitary Products Group 13 036-21342-002 Rev. E (0505) COOLING PERFORMANCE DATA E4TS036S06A WITH N1VSC1606 / G2FD048S21 - HIGH CFM 2-CYLINDER OPERATION ID CFM CONDENSER ENTERING AIR ID DB (°F) TEMPERATURE ID WB (°F) T.C. 75 S.C. K.W. T.C. 85 S.C. K.W. T.C. 95 S.C. K.W. T.C. 105 S.C. K.W. T.C. 115 S.C. K.W. T.C. 125 S.C. K.W. 80 72 42.71 21.26 2.61 40.45 20.15 2.84 38.19 19.04 3.08 35.93 17.93 3.32 33.74 16.85 3.55 31.54 15.77 3.78 80 67 39.07 25.43 2.58 37.03 24.74 2.79 34.99 24.05 2.99 32.95 23.36 3.20 30.98 22.69 3.40 29.00 22.02 3.60 1000 80 62 35.00 31.63 2.47 33.34 30.32 2.67 31.68 29.02 2.87 30.02 27.71 3.07 28.42 26.44 3.26 26.81 25.17 3.45 75 62 35.00 26.34 2.47 33.34 25.03 2.67 31.68 23.72 2.87 30.02 22.42 3.07 28.42 21.15 3.26 26.81 19.88 3.45 80 57 33.88 32.81 2.46 32.20 31.29 2.65 30.51 29.77 2.85 28.83 28.26 3.05 27.19 26.79 3.24 25.56 25.31 3.42 80 72 43.34 21.75 2.73 40.99 20.83 2.96 38.64 19.90 3.20 36.29 18.97 3.43 34.01 18.07 3.66 31.73 17.18 3.88 80 67 40.24 27.35 2.68 38.12 26.61 2.89 36.00 25.61 3.10 33.88 25.12 3.31 31.83 24.40 3.51 29.77 23.68 3.71 1185 80 62 36.13 33.71 2.58 34.47 32.25 2.79 32.81 30.79 2.99 31.15 29.33 3.20 29.53 27.91 3.40 27.92 26.49 3.60 75 62 36.13 28.25 2.58 34.47 26.76 2.79 32.81 25.26 2.99 31.15 23.77 3.20 29.53 22.31 3.40 27.92 20.86 3.60 80 57 36.54 36.00 2.55 34.69 34.23 2.73 32.83 32.46 2.93 30.98 30.70 3.15 29.18 28.98 3.36 27.39 27.26 3.55 80 72 43.97 22.25 2.85 41.53 21.51 3.08 39.09 20.76 3.31 36.65 20.02 3.54 34.29 19.30 3.77 31.92 18.58 3.99 80 67 41.41 29.27 2.79 39.21 28.48 3.00 37.01 27.68 3.21 34.81 26.89 3.42 32.67 26.12 3.62 30.54 25.34 3.82 1350 80 62 37.26 35.79 2.69 35.60 34.18 2.90 33.93 32.56 3.12 32.27 30.94 3.33 30.65 29.38 3.54 29.04 27.81 3.75 75 62 37.26 30.17 2.69 35.60 28.48 2.90 33.93 26.80 3.12 32.27 25.11 3.33 30.65 23.48 3.54 29.04 21.84 3.75 80 57 39.19 39.19 2.64 37.17 37.17 2.82 35.15 35.15 3.01 33.13 33.13 3.24 31.18 31.18 3.47 29.22 29.22 3.68 Multipliers for determining the performance with other indoor sections. HIGH CFM Air Handler Coil T.C. S.C. KW N1VSD20 G2FD048S24 1.01 1.02 1.00 Variable Speed Coil Furnace T.C. S.C. KW P1DUC20V G1UA048S21 0.99 1.01 1.03 P1DUC20V G1FA048S21 0.99 1.01 1.03 P1DUC20V G2FD048S21 1.00 1.02 1.03 1.05 Variable Speed Coil Furnace T.C. S.C. KW P1XDB12V G2FD046S17 0.99 1.01 1.06 P1DUC20V G1UA060S21 1.03 1.04 P1XUB12V G2FD046S17 0.98 1.00 1.04 P1DUC20V G1FA060S21 1.03 1.04 1.05 P1XUB12V G1UA048S17 0.98 1.00 1.04 P1XUC20V G1UA048S21 0.99 1.00 1.04 P1XUB12V G1FA048S17 0.98 1.00 1.04 P1XUC20V G1FA048S21 0.99 1.00 1.04 P1DUB16V G2FD046S17 0.99 1.00 1.04 P1XUC20V G2FD048S21 0.99 1.01 1.03 P1DUB16V G1UA048S17 0.99 1.00 1.04 P1XUC20V G1UA060S21 1.02 1.03 1.05 P1DUB16V G1FA048S17 0.99 1.00 1.04 P1XUC20V G1FA060S21 1.02 1.03 1.05 P1DUC16V G1UA048S21 0.99 1.01 1.04 P1XDD20V G2FD048S24 1.00 1.07 1.03 P1DUC16V G1FA048S21 0.99 1.01 1.04 P1XUD20V G1UA048S24 1.01 1.06 1.04 P1DUC16V G2FD048S21 1.00 1.02 1.05 P1XUD20V G1FA048S24 1.01 1.06 1.04 P1DUC16V G1UA060S21 1.03 1.04 1.06 P1XUD20V G2FD048S24 1.01 1.07 1.03 P1DUC16V G1FA060S21 1.03 1.04 1.06 P1XUD20V G1UA060S24 1.04 1.09 1.04 P1XUD20V G1FA060S24 1.04 1.09 1.04 NOTE: KW RATING IS FOR OUTDOOR AND INDOOR UNITS. 14 Unitary Products Group 036-21342-002 Rev. E (0505) COOLING PERFORMANCE DATA E4TS036S06A WITH N1VSC1606 / G2FD048S21 - LOW CFM 1-CYLINDER OPERATION ID CFM CONDENSER ENTERING AIR ID DB (°F) TEMPERATURE ID WB (°F) T.C. 75 S.C. K.W. T.C. 85 S.C. K.W. T.C. 95 S.C. K.W. 80 72 25.53 12.14 1.35 24.11 11.53 1.48 22.70 10.93 1.62 80 67 22.96 15.13 1.35 21.94 14.70 1.47 20.91 14.27 1.58 680 80 62 21.67 18.09 1.33 20.57 17.83 1.45 19.46 17.56 1.56 75 62 21.67 14.65 1.33 20.57 14.38 1.45 19.46 14.12 1.56 80 57 19.33 19.09 1.33 18.91 18.63 1.44 18.49 18.17 1.56 80 72 25.89 12.67 1.37 24.68 12.20 1.50 23.47 11.73 1.64 80 67 23.72 16.04 1.37 22.56 15.80 1.49 21.40 15.40 1.61 770 80 62 22.21 19.20 1.36 21.14 18.30 1.47 20.08 17.40 1.59 75 62 22.21 15.76 1.36 21.14 14.82 1.47 20.08 13.89 1.59 80 57 20.25 20.13 1.34 19.62 19.48 1.46 19.00 18.84 1.58 80 72 26.24 13.20 1.39 25.25 12.87 1.53 24.25 12.54 1.66 80 67 24.48 16.95 1.38 23.19 16.91 1.51 21.89 16.87 1.63 860 80 62 22.74 20.32 1.38 21.72 18.78 1.50 20.70 17.24 1.61 75 62 22.74 16.87 1.38 21.72 15.26 1.50 20.70 13.66 1.61 80 57 21.17 21.17 1.35 20.34 20.34 1.47 19.51 19.51 1.60 Multipliers for determining the performance with other indoor sections. LOW CFM Air Handler Coil T.C. S.C. KW N1VSD20 G2FD048S24 1.01 1.01 0.99 Variable Speed Coil Furnace T.C. S.C. KW P1DUC20V G1UA048S21 0.94 0.99 1.00 P1DUC20V G1FA048S21 0.94 0.99 1.00 P1DUC20V G2FD048S21 0.95 1.00 0.99 G1UA060S21 0.98 1.03 1.00 Variable Speed Coil Furnace T.C. S.C. KW P1XDB12V 0.93 0.99 1.00 P1DUC20V G2FD046S17 P1XUB12V G2FD046S17 0.93 0.97 0.98 P1DUC20V G1FA060S21 0.98 1.03 1.00 P1XUB12V G1UA048S17 0.93 0.97 0.98 P1XUC20V G1UA048S21 0.93 0.97 0.99 P1XUB12V G1FA048S17 0.93 0.97 0.98 P1XUC20V G1FA048S21 0.93 0.97 0.99 P1DUB16V G2FD046S17 0.93 0.97 0.99 P1XUC20V G2FD048S21 0.94 0.99 0.99 P1DUB16V G1UA048S17 0.93 0.97 0.99 P1XUC20V G1UA060S21 0.97 1.01 0.99 P1DUB16V G1FA048S17 0.93 0.97 0.99 P1XUC20V G1FA060S21 0.97 1.01 0.99 P1DUC16V G1UA048S21 0.94 0.99 1.00 P1XDD20V G2FD048S24 0.95 1.05 0.98 P1DUC16V G1FA048S21 0.94 0.99 1.00 P1XUD20V G1UA048S24 0.96 1.04 1.00 P1DUC16V G2FD048S21 0.95 1.00 1.01 P1XUD20V G1FA048S24 0.96 1.04 1.00 P1DUC16V G1UA060S21 0.98 1.03 1.00 P1XUD20V G2FD048S24 0.97 1.05 0.99 P1DUC16V G1FA060S21 0.98 1.03 1.00 P1XUD20V G1UA060S24 1.00 1.08 1.00 P1XUD20V G1FA060S24 1.00 1.08 1.00 NOTE: KW RATING IS FOR OUTDOOR AND INDOOR UNITS. Unitary Products Group 15 036-21342-002 Rev. E (0505) COOLING PERFORMANCE DATA E4TS048S06A WITH N1VSD2006 / G2FD060S24 - HIGH CFM 2-CYLINDER OPERATION ID CFM CONDENSER ENTERING AIR ID DB (°F) TEMPERATURE ID WB (°F) T.C. 75 S.C. K.W. T.C. 85 S.C. K.W. T.C. 95 S.C. K.W. T.C. 105 S.C. K.W. T.C. 115 S.C. K.W. T.C. 125 S.C. K.W. 80 72 56.47 28.32 3.61 53.54 27.19 3.91 50.60 26.05 4.21 47.67 24.92 4.50 44.83 23.83 4.79 41.98 22.73 5.08 80 67 53.15 36.17 3.49 50.52 35.23 3.77 47.89 34.28 4.04 45.26 33.33 4.32 42.71 32.41 4.59 40.16 31.50 4.86 1420 80 62 46.83 42.10 3.34 44.60 41.03 3.59 42.38 39.96 3.84 40.15 38.89 4.08 37.99 37.85 4.33 35.83 36.81 4.57 75 62 46.83 34.23 3.34 44.60 33.16 3.59 42.38 32.09 3.84 40.15 31.02 4.08 37.99 29.98 4.33 35.83 28.94 4.57 80 57 39.34 38.85 3.30 38.36 37.86 3.54 37.29 36.87 3.81 35.74 35.52 4.04 34.19 34.03 4.26 32.61 32.58 4.48 80 72 56.73 29.16 3.79 53.57 27.99 4.09 50.42 26.81 4.39 47.26 25.63 4.69 44.20 24.49 4.98 41.14 23.34 5.27 80 67 53.18 37.77 3.66 50.59 36.86 3.94 48.00 35.60 4.21 45.41 35.04 4.49 42.90 34.16 4.76 40.39 33.28 5.03 1600 80 62 47.38 43.94 3.48 45.30 42.50 3.74 43.22 41.06 3.99 41.14 39.63 4.25 39.13 38.23 4.50 37.11 36.84 4.75 75 62 47.38 36.08 3.48 45.30 34.61 3.74 43.22 33.14 3.99 41.14 31.66 4.25 39.13 30.23 4.50 37.11 28.80 4.75 80 57 40.76 40.51 3.36 39.65 39.40 3.60 38.48 38.27 3.87 37.04 36.93 4.16 35.62 35.53 4.38 34.54 34.52 4.64 80 72 56.99 30.01 3.97 53.61 28.79 4.28 50.24 27.56 4.58 46.86 26.34 4.88 43.58 25.15 5.18 40.30 23.96 5.47 80 67 53.21 39.37 3.82 50.66 38.50 4.10 48.11 37.63 4.38 45.56 36.76 4.66 43.09 35.91 4.93 40.62 35.06 5.20 1750 80 62 47.93 45.77 3.62 46.00 43.97 3.89 44.07 42.17 4.15 42.13 40.36 4.42 40.26 38.61 4.68 38.38 36.86 4.93 75 62 47.93 37.93 3.62 46.00 36.06 3.89 44.07 34.18 4.15 42.13 32.30 4.42 40.26 30.48 4.68 38.38 28.66 4.93 80 57 42.18 42.18 3.41 40.94 40.94 3.66 39.66 39.66 3.94 38.34 38.34 4.29 37.04 37.04 4.49 36.46 36.46 4.80 80 72 32.53 16.84 1.66 30.30 16.20 1.84 28.06 15.56 2.01 80 67 30.07 22.62 1.64 28.44 22.33 1.81 26.80 22.03 1.97 1140 80 62 27.86 24.57 1.62 26.54 23.99 1.77 25.22 23.42 1.91 75 62 27.86 19.60 1.62 26.54 19.00 1.77 25.22 18.40 1.91 80 57 25.63 25.63 1.60 26.43 26.43 1.74 23.20 23.20 1.87 E4TS048S06A WITH N1VSD2006 / G2FD060S24 - LOW CFM 1-CYLINDER OPERATION ID CFM CONDENSER ENTERING AIR ID DB (°F) TEMPERATURE ID WB (°F) T.C. 75 S.C. K.W. T.C. 85 S.C. K.W. T.C. 95 S.C. K.W. 80 72 28.53 13.88 1.67 28.30 14.72 1.84 28.06 15.56 2.01 80 67 27.17 20.03 1.62 26.99 21.03 1.79 26.80 22.03 1.97 850 80 62 25.56 22.49 1.57 25.39 23.45 1.74 25.22 24.42 1.91 75 62 25.56 18.01 1.57 25.39 18.97 1.74 25.22 19.93 1.91 80 57 24.29 23.48 1.51 24.12 23.45 1.69 25.01 24.67 1.85 80 72 30.53 15.36 1.67 29.30 15.46 1.84 28.06 15.56 2.01 80 67 28.62 21.33 1.63 27.71 21.68 1.80 26.80 21.80 1.97 1040 80 62 26.71 23.53 1.60 25.97 23.72 1.76 25.22 23.92 1.91 75 62 26.71 18.80 1.60 25.97 18.98 1.76 25.22 19.17 1.91 80 57 24.96 24.56 1.56 25.28 24.94 1.71 24.11 23.94 1.86 Multipliers for determining the performance with other indoor sections. HIGH CFM LOW CFM Air Handler Coil T.C. S.C. KW Air Handler Coil T.C. S.C. KW N1VSD20 G1FD061S24 G1FD061S24 1.02 1.02 1.00 N1VSD20 1.02 1.02 1.01 F(2,3)FV060 1.00 1.00 1.00 F(2,3)FV060 1.00 1.00 1.00 Variable Speed Coil Furnace T.C. S.C. KW Variable Speed Coil Furnace T.C. S.C. KW 0.96 P1DUC16V G1UA060S21 0.98 0.95 1.03 P1DUC16V G1UA060S21 0.89 0.81 P1DUC16V G1FA060S21 0.98 0.95 1.03 P1DUC16V G1FA060S21 0.89 0.81 0.96 P1DUC20V G1UA060S21 0.99 0.96 1.04 P1DUC20V G1UA060S21 0.90 0.83 0.97 P1DUC20V G1FA060S21 0.99 0.96 1.04 P1DUC20V G1FA060S21 0.90 0.83 0.97 P1XUC20V G1UA060S21 0.98 0.95 1.03 P1XUC20V G1UA060S21 0.88 0.80 0.95 P1XUC20V G1FA060S21 0.98 0.95 1.03 P1XUC20V G1FA060S21 0.88 0.80 0.95 P1XDD20V G2FD060S24 0.99 0.96 1.03 P1XDD20V G2FD060S24 0.91 0.84 0.99 P1XDD20V G2FD061H24 1.01 0.98 1.03 P1XDD20V G2FD061H24 0.93 0.86 0.99 P1XUD20V G1UA060S24 1.00 0.97 1.04 P1XUD20V G1UA060S24 0.93 0.86 0.99 P1XUD20V G1FA060S24 1.00 0.97 1.04 P1XUD20V G1FA060S24 0.93 0.86 0.99 P1XUD20V G2FD060S24 1.00 0.97 1.04 P1XUD20V G2FD060S24 0.93 0.86 0.99 P1XUD20V G2FD061H24 1.02 0.99 1.03 P1XUD20V G2FD061H24 0.94 0.86 0.99 NOTE: KW RATING IS FOR OUTDOOR AND INDOOR UNITS. 16 Unitary Products Group 036-21342-002 Rev. E (0505) COOLING PERFORMANCE DATA E4TS060S06A WITH N1VSD2006 / G2FD061S24 - HIGH CFM 2-CYLINDER OPERATION ID CFM CONDENSER ENTERING AIR ID DB (°F) TEMPERATURE ID WB (°F) T.C. 75 S.C. K.W. T.C. 85 S.C. K.W. T.C. 95 S.C. K.W. T.C. 105 S.C. K.W. T.C. 115 S.C. K.W. T.C. 125 S.C. K.W. 80 72 65.80 32.90 4.53 62.52 31.56 4.95 59.25 30.22 5.30 55.97 28.89 5.66 52.79 27.59 6.06 49.61 26.29 6.43 80 67 61.90 42.32 4.43 58.95 41.12 4.77 56.00 39.93 5.10 53.05 38.73 5.44 50.19 37.57 5.76 47.33 36.41 6.09 1540 80 62 55.01 49.80 4.30 52.76 48.61 4.58 50.51 47.42 4.85 48.27 46.23 5.13 46.09 45.08 5.40 43.91 43.93 5.66 75 62 55.01 40.94 4.30 52.76 39.75 4.58 50.51 38.57 4.85 48.27 37.38 5.13 46.09 36.22 5.40 43.91 35.07 5.66 80 57 53.57 51.43 4.20 51.36 49.31 4.49 49.15 47.19 4.78 46.94 44.68 5.07 44.80 42.43 5.35 42.66 40.19 5.64 80 72 65.60 33.42 4.76 62.48 32.21 5.15 59.36 31.01 5.51 56.25 29.80 5.87 53.22 28.63 6.25 50.19 27.46 6.62 80 67 63.40 44.11 4.66 60.20 43.00 4.99 57.00 41.50 5.38 53.80 40.79 5.64 50.70 39.72 5.96 47.59 38.64 6.27 1860 80 62 57.21 51.70 4.50 54.76 50.40 4.78 52.31 49.09 5.07 49.85 47.79 5.35 47.47 46.52 5.63 45.10 45.25 5.91 75 62 57.21 42.35 4.50 54.76 41.02 4.78 52.31 39.69 5.07 49.85 38.35 5.35 47.47 37.06 5.63 45.10 35.77 5.91 80 57 56.10 55.02 4.43 53.68 52.66 4.72 51.27 50.29 5.00 48.86 47.73 5.30 46.52 45.33 5.58 44.17 42.94 5.86 80 72 65.40 33.94 4.99 62.44 32.86 5.35 59.48 31.79 5.72 56.52 30.71 6.09 53.64 29.67 6.44 50.77 28.63 6.80 80 67 64.90 45.90 4.89 61.45 44.88 5.21 58.00 43.87 5.52 54.55 42.85 5.84 51.21 41.86 6.15 47.86 40.87 6.46 2075 80 62 59.41 53.60 4.69 56.75 52.18 4.99 54.10 50.76 5.28 51.44 49.34 5.58 48.86 47.96 5.86 46.28 46.58 6.15 75 62 59.41 43.76 4.69 56.75 42.28 4.99 54.10 40.81 5.28 51.44 39.33 5.58 48.86 37.90 5.86 46.28 36.46 6.15 80 57 58.62 58.62 4.65 56.00 56.00 4.94 53.39 53.39 5.22 50.77 50.77 5.53 48.23 48.23 5.81 45.69 45.69 6.08 80 72 36.12 19.97 1.82 34.76 19.47 2.05 33.39 18.96 2.28 80 67 33.70 25.56 1.81 31.92 25.50 2.03 30.13 25.44 2.25 1350 80 62 31.31 30.93 1.81 29.90 28.59 2.02 28.49 26.25 2.23 75 62 31.31 22.39 1.81 29.90 19.98 2.02 28.49 17.56 2.23 80 57 29.15 29.15 1.77 28.00 28.00 1.98 26.85 26.85 2.19 E4TS060S06A WITH N1VSD2006 / G2FD061S24 - LOW CFM 1-CYLINDER OPERATION ID CFM CONDENSER ENTERING AIR ID DB (°F) TEMPERATURE ID WB (°F) T.C. 75 S.C. K.W. T.C. 85 S.C. K.W. T.C. 95 S.C. K.W. 80 72 32.55 17.01 1.63 30.74 16.16 1.85 28.93 15.31 2.07 80 67 29.26 21.12 1.64 27.96 20.52 1.83 26.66 19.92 2.03 1000 80 62 27.63 25.18 1.61 26.21 24.82 1.81 24.80 24.45 2.00 75 62 27.63 18.13 1.61 26.21 17.77 1.81 24.80 17.40 2.00 80 57 24.63 23.65 1.61 24.10 23.14 1.79 23.57 22.63 1.98 80 72 34.33 18.49 1.73 32.75 17.81 1.95 31.16 17.14 2.18 80 67 31.48 23.34 1.72 29.94 23.01 1.93 29.00 24.00 2.16 1200 80 62 29.47 28.06 1.71 28.06 26.70 1.91 26.65 25.35 2.12 75 62 29.47 20.26 1.71 28.06 18.87 1.91 26.65 17.48 2.12 80 57 26.89 26.40 1.69 26.05 25.57 1.89 25.21 24.74 2.09 Multipliers for determining the performance with other indoor sections. HIGH CFM LOW CFM Air Handler Coil T.C. S.C. KW Air Handler Coil T.C. S.C. KW N1VSD20 G1FD060S24 0.97 0.98 0.99 N1VSD20 G1FD060S24 0.96 0.98 0.98 F(2,3)FV060 0.97 0.98 0.99 F(2,3)FV060 0.96 0.98 0.98 Variable Speed Coil Furnace T.C. S.C. KW Variable Speed Coil Furnace T.C. S.C. KW P1XDD20V G2FD060S24 0.96 0.95 1.02 P1XDD20V G2FD060S24 0.93 0.85 0.99 P1XDD20V G2FD061H24 0.98 0.96 1.02 P1XDD20V G2FD061H24 0.97 0.87 1.01 P1XUD20V G1UA060S24 0.97 0.96 1.01 P1XUD20V G1UA060S24 0.93 0.85 1.00 P1XUD20V G1FA060S24 0.97 0.96 1.01 P1XUD20V G1FA060S24 0.93 0.85 1.00 P1XUD20V G2FD060S24 0.97 0.96 1.01 P1XUD20V G2FD060S24 0.93 0.85 1.00 P1XUD20V G2FD061H24 0.99 0.98 1.01 P1XUD20V G2FD061H24 0.97 0.87 1.01 NOTE: KW RATING IS FOR OUTDOOR AND INDOOR UNITS. Unitary Products Group 17 036-21342-002 Rev. E (0505) HEATING PERFORMANCE DATA E4TS030S06A WITH N1VSC1606 / G2FD048S21 - HIGH CFM 2-CYLINDER OPERATION ID CFM OD DB 980 ID DB (°F) 60 70 80 60 70 80 60 70 80 60 70 80 60 70 80 60 70 80 60 47 35 17 7 -3 MBTUH1,2 35.86 33.48 31.09 28.88 26.78 24.68 22.40 20.57 18.73 16.95 15.20 13.46 12.23 11.24 10.24 7.92 7.28 6.63 1065 KW 2.17 2.30 2.43 2.04 2.14 2.24 1.90 1.98 2.05 1.71 1.77 1.83 1.50 1.57 1.64 1.37 1.43 1.49 1210 MBTUH1,2 36.10 33.93 31.77 29.01 27.00 24.99 22.79 20.94 19.10 17.09 15.40 13.71 12.34 11.39 10.43 7.99 7.37 6.75 KW 2.19 2.31 2.44 2.07 2.17 2.26 1.92 2.00 2.08 1.74 1.84 1.94 1.52 1.60 1.68 1.39 1.46 1.53 MBTUH1,2 36.34 34.39 32.44 29.14 27.22 25.29 23.17 21.31 19.46 17.22 15.60 13.97 12.45 11.53 10.62 8.06 7.47 6.87 KW 2.20 2.32 2.45 2.09 2.19 2.29 1.94 2.02 2.10 1.78 1.83 1.88 1.54 1.61 1.68 1.41 1.47 1.53 E4TS030S06A WITH N1VSC1606 / G2FD048S21 - LOW CFM 1-CYLINDER OPERATION ID CFM OD DB 650 720 770 ID DB (°F) MBTUH1,2 KW MBTUH1,2 KW MBTUH1,2 KW 60 70 80 60 70 80 60 70 80 20.36 18.50 16.64 16.02 14.90 13.77 12.60 12.00 11.40 1.08 1.16 1.24 1.05 1.12 1.19 1.02 1.08 1.13 20.52 18.66 16.79 16.15 15.00 13.85 12.71 12.07 11.42 1.09 1.17 1.25 1.06 1.13 1.20 1.04 1.10 1.15 20.67 18.81 16.95 16.28 15.10 13.93 12.82 12.13 11.45 1.09 1.17 1.25 1.08 1.14 1.20 1.07 1.12 1.16 60 47 35 For notes see Page 11. Multipliers for determining the performance with other indoor sections. 2-CYLINDER OPERATION 1-CYLINDER OPERATION HIGH CFM LOW CFM Air Handler Coil N1VSB12 G2FD046S17 0.98 0.99 0.91 N1VSC16 G2FD042S21 0.96 0.98 0.90 Variable Speed Coil Furnace LOW CFM Air Handler Coil 0.96 N1VSB12 G2FD046S17 0.89 0.91 0.95 N1VSC16 G2FD042S21 0.88 0.90 MBTUH KW MBTUH KW MBTUH KW MBTUH KW Variable Speed Coil Furnace MBTUH KW MBTUH KW P1XDB12V G2FD046S17 0.97 1.00 0.89 0.94 P1XDB12V G2FD046S17 0.85 0.93 P1XUB12V G2FD046S17 0.96 1.00 0.88 0.95 P1XUB12V G2FD046S17 0.85 0.93 P1XUB12V G1UA048S17 0.96 1.00 0.88 0.95 P1XUB12V G1UA048S17 0.85 0.93 P1XUB12V G1FA048S17 0.96 1.00 0.88 0.95 P1XUB12V G1FA048S17 0.85 0.93 P1DUB16V G2FD046S17 0.98 1.00 0.90 0.95 P1DUB16V G2FD046S17 0.83 0.91 P1DUB16V G1UA048S17 0.98 1.00 0.90 0.95 P1DUB16V G1UA048S17 0.83 0.91 P1DUB16V G1FA048S17 0.98 1.00 0.90 0.95 P1DUB16V G1FA048S17 0.83 0.91 P1DUC16V G2FD042S21 1.00 1.00 0.92 0.95 P1DUC16V G2FD042S21 0.87 0.91 P1DUC16V G1UA048S21 1.01 1.01 0.93 0.96 P1DUC16V G1UA048S21 0.88 0.92 P1DUC16V GFA048S21 1.01 1.01 0.93 0.96 P1DUC16V GFA048S21 0.88 0.92 P1DUC16V G2FD048S21 1.02 1.02 0.94 0.97 P1DUC16V G2FD048S21 0.89 0.92 NOTE: KW RATING IS FOR OUTDOOR AND INDOOR UNITS. 18 Unitary Products Group 036-21342-002 Rev. E (0505) HEATING PERFORMANCE DATA E4TS036S06A WITH N1VSC1606 / G2FD048S21 - HIGH CFM 2-CYLINDER OPERATION ID CFM OD DB 1000 ID DB (°F) 60 70 80 60 70 80 60 70 80 60 70 80 60 70 80 60 70 80 60 47 35 17 7 -3 MBTUH1,2 42.57 40.33 38.08 38.00 35.19 32.38 30.23 27.59 24.96 22.29 20.61 18.93 17.34 16.08 14.83 12.18 11.30 10.42 1185 KW 2.80 2.98 3.17 2.63 2.77 2.91 2.37 2.48 2.59 2.14 2.22 2.29 1.92 2.02 2.12 1.76 1.85 1.94 1350 MBTUH1,2 43.13 40.99 38.85 38.09 35.60 33.11 30.03 27.79 25.56 22.47 21.20 19.93 17.41 16.34 15.27 12.23 11.48 10.73 KW 2.81 2.99 3.17 2.64 2.79 2.94 2.40 2.52 2.64 2.20 2.27 2.34 1.95 2.05 2.14 1.79 1.88 1.97 MBTUH1,2 43.69 41.65 39.61 38.18 36.01 33.83 29.82 27.99 26.16 22.64 21.79 20.94 17.48 16.60 15.71 12.28 11.66 11.04 KW 2.82 3.00 3.18 2.66 2.81 2.96 2.44 2.57 2.69 2.25 2.32 2.39 1.97 2.07 2.17 1.81 1.90 1.99 For notes see Page 11. Multipliers for determining the performance with other indoor sections. 2-CYLINDER OPERATION Air Handler Coil N1VSB12 G2FD046S17 Variable Speed Coil Furnace HIGH CFM LOW CFM MBTUH KW MBTUH KW 0.98 1.04 0.89 0.94 MBTUH KW MBTUH KW P1XDB12V G2FD046S17 0.97 1.03 0.87 0.96 P1XUB12V G2FD046S17 0.97 1.02 0.87 0.95 P1XUB12V G1UA048S17 0.98 1.03 0.88 0.95 P1XUB12V G1FA048S17 0.98 1.03 0.88 0.95 P1DUB16V G2FD046S17 0.97 1.02 0.87 0.95 P1DUB16V G1UA048S17 0.98 1.03 0.88 0.95 P1DUB16V G1FA048S17 0.98 1.03 0.88 0.95 P1DUC16V G1UA048S21 0.99 1.02 0.89 0.95 P1DUC16V G1FA048S21 0.99 1.02 0.89 0.95 P1DUC16V G2FD048S21 1.00 1.02 0.90 0.95 P1DUC16V G1UA060S21 1.01 1.01 0.91 0.94 P1DUC16V G1FA060S21 1.01 1.01 0.91 0.94 Variable Speed Coil Furnace HIGH CFM LOW CFM MBTUH KW MBTUH KW P1DUC20V G1UA048S21 0.99 1.03 0.89 P1DUC20V G1FA048S21 0.99 1.03 0.89 0.95 P1DUC20V G2FD048S21 1.00 1.02 0.90 0.95 P1DUC20V G1UA060S21 1.02 1.02 0.92 0.95 P1DUC20V G1FA060S21 1.02 1.02 0.92 0.95 P1XUC20V G1UA048S21 0.99 1.03 0.89 0.96 P1XUC20V G1FA048S21 0.99 1.03 0.89 0.96 P1XUC20V G2FD048S21 1.00 1.03 0.90 0.95 P1XUC20V G1UA060S21 1.02 1.03 0.92 0.96 P1XUC20V G1FA060S21 1.02 1.03 0.92 0.96 P1XDD20V G2FD048S24 1.00 0.98 0.90 0.91 P1XUD20V G1UA048S24 1.02 1.00 0.92 0.93 P1XUD20V G1FA048S24 1.02 1.00 0.92 0.93 P1XUD20V G2FD048S24 1.02 1.00 0.92 0.93 P1XUD20V G1UA060S24 1.04 1.00 0.94 0.93 P1XUD20V G1FA060S24 1.04 1.00 0.94 0.93 NOTE: KW RATING IS FOR OUTDOOR AND INDOOR UNITS. Unitary Products Group 0.95 19 036-21342-002 Rev. E (0505) HEATING PERFORMANCE DATA E4TS036S06A WITH N1VSC1606 / G2FD048S21 - LOW CFM 1-CYLINDER OPERATION ID CFM OD DB 670 ID DB (°F) 60 70 80 60 70 80 60 70 80 60 47 35 770 MBTUH1,2 24.27 22.72 21.16 21.43 19.73 18.03 18.92 17.14 15.35 KW 1.49 1.59 1.70 1.42 1.51 1.59 1.36 1.42 1.49 860 MBTUH1,2 24.88 23.42 21.96 21.73 20.00 18.42 18.99 17.22 15.45 MBTUH1,2 25.48 24.13 22.77 22.04 20.42 18.81 19.06 17.30 15.54 KW 1.50 1.61 1.71 1.43 1.52 1.61 1.36 1.44 1.51 KW 1.51 1.62 1.73 1.44 1.53 1.62 1.37 1.45 1.52 For notes see Page 11. Multipliers for determining the performance with other indoor sections. 1-CYLINDER OPERATION Air Handler Coil N1VSB12 G2FD046S17 Variable Speed Coil Furnace LOW CFM LOW CFM MBTUH KW Variable Speed Coil Furnace MBTUH KW 0.98 1.00 P1DUC20V G1UA048S21 0.85 0.93 P1DUC20V G1FA048S21 0.85 0.93 P1DUC20V G2FD048S21 0.86 0.93 P1DUC20V G1UA060S21 0.88 0.94 MBTUH KW P1XDB12V G2FD046S17 0.87 0.94 P1XUB12V G2FD046S17 0.86 0.94 P1XUB12V G1UA048S17 0.87 0.94 P1XUB12V G1FA048S17 0.87 0.94 P1DUB16V G2FD046S17 0.85 0.93 P1DUB16V G1UA048S17 0.86 0.93 P1DUB16V G1FA048S17 0.86 0.93 P1DUC16V G1UA048S21 0.85 0.93 P1DUC16V G1FA048S21 0.85 0.93 P1DUC16V G2FD048S21 0.86 0.93 P1DUC16V G1UA060S21 0.88 0.94 P1DUC16V G1FA060S21 0.88 0.94 P1DUC20V G1FA060S21 0.88 0.94 P1XUC20V G1UA048S21 0.83 0.92 P1XUC20V G1FA048S21 0.83 0.92 P1XUC20V G2FD048S21 0.84 0.92 P1XUC20V G1UA060S21 0.86 0.93 P1XUC20V G1FA060S21 0.86 0.93 P1XDD20V G2FD048S24 0.90 0.98 P1XUD20V G1UA048S24 0.90 0.99 P1XUD20V G1FA048S24 0.90 0.99 P1XUD20V G2FD048S24 0.91 0.99 P1XUD20V G1UA060S24 0.94 1.00 P1XUD20V G1FA060S24 0.94 1.00 NOTE: KW RATING IS FOR OUTDOOR AND INDOOR UNITS. 20 Unitary Products Group 036-21342-002 Rev. E (0505) HEATING PERFORMANCE DATA E4TS048S06A WITH N1VSD2006 / G2FD060S24 - HIGH CFM 2-CYLINDER OPERATION ID CFM OD DB 1420 ID DB (°F) 60 70 80 60 70 80 60 70 80 60 70 80 60 70 80 60 70 80 60 47 35 17 7 -3 MBTUH1,2 58.57 55.72 52.87 48.43 46.01 43.60 39.06 36.62 34.17 28.62 26.00 23.38 21.24 19.89 18.55 14.73 13.79 12.86 1600 KW 4.00 4.22 4.44 3.61 3.79 3.96 3.24 3.38 3.52 2.97 3.05 3.13 2.68 2.79 2.91 2.48 2.58 2.69 1750 MBTUH1,2 59.37 56.47 53.56 49.54 47.00 44.46 39.49 37.06 34.63 28.81 26.40 23.99 21.53 20.21 18.88 14.93 14.01 13.09 KW 4.01 4.24 4.47 3.66 3.85 4.03 3.31 3.46 3.62 3.06 3.16 3.26 2.72 2.85 2.98 2.53 2.64 2.76 MBTUH1,2 60.17 57.21 54.26 50.65 47.99 45.32 39.92 37.51 35.09 29.00 26.80 24.60 21.82 20.52 19.22 15.13 14.22 13.32 KW 4.02 4.26 4.50 3.72 3.91 4.10 3.37 3.55 3.72 3.15 3.27 3.39 2.77 2.91 3.05 2.57 2.70 2.82 E4TS048S06A WITH N1VSD2006 / G2FD060S24 - LOW CFM 1-CYLINDER OPERATION ID CFM OD DB 850 1040 1140 ID DB (°F) MBTUH1,2 KW MBTUH1,2 KW MBTUH1,2 KW 60 70 80 60 70 80 60 70 80 29.44 27.16 24.88 25.88 23.31 20.73 22.75 20.01 17.27 1.89 2.00 2.12 1.80 1.90 1.99 1.72 1.80 1.87 30.37 28.00 25.62 26.28 23.80 21.32 22.75 20.24 17.73 1.88 2.00 2.12 1.81 1.91 2.00 1.74 1.82 1.89 31.31 28.83 26.36 26.68 24.29 21.90 22.75 20.47 18.20 1.87 2.00 2.13 1.81 1.91 2.01 1.76 1.83 1.90 60 47 35 For notes see Page 11. Multipliers for determining the performance with other indoor sections. 2-CYLINDER OPERATION Air Handler Coil N1VSD20 G1FD061S24 F(2,3)FV060 Variable Speed Coil Furnace 1-CYLINDER OPERATION HIGH CFM LOW CFM MBTUH KW MBTUH KW Air Handler Coil G1FD061S24 1.02 1.00 0.95 0.95 N1VSD20 1.00 1.00 0.93 0.95 F(2,3)FV060 MBTUH KW MBTUH KW Variable Speed Coil Furnace LOW CFM MBTUH KW 1.02 1.00 1.00 1.00 MBTUH KW 0.99 P1DUC16V G1UA060S21 1.00 1.01 0.93 0.96 P1DUC16V G1UA060S21 0.87 P1DUC16V G1FA060S21 1.00 1.01 0.93 0.96 P1DUC16V G1FA060S21 0.87 0.99 P1DUC20V G1UA060S21 1.00 0.99 0.93 0.94 P1DUC20V G1UA060S21 0.90 0.99 P1DUC20V G1FA060S21 1.00 0.99 0.93 0.94 P1DUC20V G1FA060S21 0.90 0.99 P1XUC20V G1UA060S21 0.99 1.00 0.91 0.95 P1XUC20V G1UA060S21 0.85 0.97 P1XUC20V G1FA060S21 0.99 1.00 0.91 0.95 P1XUC20V G1FA060S21 0.85 0.97 P1XDD20V G2FD060S24 0.99 1.01 0.91 0.95 P1XDD20V G2FD060S24 0.90 1.00 P1XDD20V G2FD061H24 1.01 1.01 0.94 0.95 P1XDD20V G2FD061H24 0.92 1.00 P1XUD20V G1UA060S24 1.01 1.02 0.94 0.97 P1XUD20V G1UA060S24 0.93 1.02 P1XUD20V G1FA060S24 1.01 1.02 0.94 0.97 P1XUD20V G1FA060S24 0.93 1.02 P1XUD20V G2FD060S24 1.01 1.02 0.94 0.97 P1XUD20V G2FD060S24 0.93 1.02 P1XUD20V G2FD061H24 1.03 1.02 0.96 0.97 P1XUD20V G2FD061H24 0.95 1.02 NOTE: KW RATING IS FOR OUTDOOR AND INDOOR UNITS. Unitary Products Group 21 036-21342-002 Rev. E (0505) HEATING PERFORMANCE DATA E4TS060S06A WITH N1VSD2006 / G2FD061S21 - HIGH CFM 2-CYLINDER OPERATION ID CFM OD DB 1540 ID DB (°F) 60 70 80 60 70 80 60 70 80 60 70 80 60 70 80 60 70 80 60 47 35 17 7 -3 MBTUH1,2 65.76 63.45 61.15 56.89 54.00 51.10 46.70 43.54 40.38 29.71 28.44 27.16 21.86 20.78 19.70 13.59 12.92 12.25 1860 KW 4.68 4.98 5.27 4.31 4.51 4.71 3.92 4.04 4.17 3.45 3.50 3.55 2.75 2.86 2.96 2.44 2.53 2.62 2075 MBTUH1,2 66.22 64.33 62.43 57.80 55.00 52.20 47.54 44.43 41.32 30.61 29.20 27.79 22.24 21.19 20.14 13.84 13.18 12.53 MBTUH1,2 66.68 65.20 63.72 58.70 56.00 53.30 48.37 45.31 42.25 31.51 29.96 28.41 22.63 21.60 20.57 14.08 13.44 12.80 KW 4.71 5.02 5.33 4.39 4.61 4.82 4.04 4.17 4.30 3.58 3.68 3.79 2.81 2.94 3.06 2.50 2.61 2.72 KW 4.74 5.07 5.40 4.47 4.70 4.93 4.16 4.30 4.44 3.70 3.86 4.02 2.87 3.02 3.16 2.56 2.68 2.81 E4TS060S06A WITH N1VSD2006 / G2FD061S21 - LOW CFM 1-CYLINDER OPERATION ID CFM OD DB 1000 1200 1350 ID DB (°F) MBTUH1,2 KW MBTUH1,2 KW MBTUH1,2 KW 60 70 80 60 70 80 60 70 80 36.04 33.56 31.08 26.89 25.57 24.26 17.25 17.10 16.94 2.14 2.28 2.42 2.03 2.13 2.24 1.86 1.93 2.00 36.57 34.11 31.64 28.43 26.60 24.77 19.73 18.56 17.39 2.14 2.28 2.42 2.03 2.14 2.25 1.88 1.95 2.02 37.10 34.65 32.20 29.97 27.63 25.28 22.20 20.02 17.84 2.13 2.28 2.42 2.04 2.15 2.26 1.89 1.97 2.04 60 47 35 For notes see Page 11. Multipliers for determining the performance with other indoor sections. 2-CYLINDER OPERATION Air Handler Coil N1VSD20 G1FD060S24 F(2,3)FV060 Variable Speed Coil Furnace 1-CYLINDER OPERATION HIGH CFM LOW CFM MBTUH KW MBTUH KW Coil G1FD060S24 0.98 1.00 0.93 0.98 N1VSD20 0.98 1.00 0.93 0.98 F(2,3)FV060 MBTUH KW MBTUH KW P1XDD20V112 G2FD060S24 0.98 0.99 P1XDD20V112 G2FD061H24 1.00 0.99 P1XUD20V112 G1UA060S24 0.98 0.98 P1XUD20V112 G1FA060S24 0.98 0.98 P1XUD20V112 G2FD060S24 0.98 0.98 P1XUD20V112 G2FD061H24 1.00 0.98 0.90 LOW CFM Air Handler Variable Speed Coil Furnace MBTUH KW 0.89 0.91 0.88 0.90 MBTUH KW 0.88 0.95 0.94 P1XDD20V112 G2FD060S24 0.92 0.95 P1XDD20V112 G2FD061H24 0.88 0.92 0.90 0.93 P1XUD20V112 G1UA060S24 0.87 0.95 0.90 0.93 P1XUD20V112 G1FA060S24 0.87 0.95 0.90 0.93 P1XUD20V112 G2FD060S24 0.87 0.95 0.92 0.93 P1XUD20V112 G2FD061H24 0.87 0.93 NOTE: KW RATING IS FOR OUTDOOR AND INDOOR UNITS. 22 Unitary Products Group 036-21342-002 Rev. E (0505) MATCHING INDOOR COMPONENTS G1UA UPFLOW G2FD* MULTI-POSITION (UPFLOW, HORIZONTAL AND DOWNFLOW) G1FA FULL CASED AIR HANDLERS - FOR NON-FURNACE APPLICATIONS N1VS MODULAR BLOWER (UPFLOW, HORIZONTAL AND DOWNFLOW) G2FD COIL Unitary Products Group F2FV FAN COIL UNITS (UPFLOW, HORIZONTAL) 23 NOTES Subject to change without notice. Printed in U.S.A. Copyright © by York International Corp. 2005. All rights reserved. Unitary Product Group 036-21342-002 Rev. E (0505) Supersedes: 036-21342-002 Rev. D (1104) 5005 York Drive Norman OK 73069