Download York E4TS030 User's Manual

Transcript
036-21342-002 Rev. E (0505)
®
DESCRIPTION
The ETS Stealth series heat pump units use Twin Single™
compressor technology to provide cooling efficiencies up to
15.7 SEER and heating efficiencies up to 9.3 HSPF. They are
to be installed with the matching variable speed Enhancer air
handler or Diamond furnace, a corresponding coil and sweat
connect lines. A factory specified balanced port hard shut-off
TXV kit must be used for proper installation and optimum performance.
WARRANTY
TECHNICAL GUIDE
5-year limited parts warranty.
10-year limited compressor warranty.
FEATURES
STEALTH
SPLIT-SYSTEM HEAT PUMP
15 SEER
MODELS: E4TS030 THRU 060
(2.5 THRU 5 NOMINAL TONS)
RT
I FI
ED T O ARI A
S
C
O
NI
PUM P
G
UN I T
T
EA
AR
Y
H
Y
MA N U F A CT U R
PL
ER
M
E
C
R
IF
IC
AT
AR
E CT
F
U I P ME N T
O
EQ
E
C
RT
IO
NS
40
I S ION S
T A NDA R D 2
CERTIFICATION APPLIES ONLY
WHEN THE COMPLETE
SYSTEM IS LISTED
WITH ARI.
LISTED
ISO 9001
Certified Quality
Management System
Due to continuous product improvement, specific
tions are subject to change without notice.
Visit us on the web at www.york.com for the most
up-to-date technical information.
Additional rating information can be found at
www.ariprimenet.org.
QUALITY CONDENSER COILS - The coil is constructed of
copper tube and hardened aluminum fins for durability and long
lasting efficient operation. The fins on the unit are protected
with a decorative grille.
DURABLE FINISH - Cabinet is made of powder painted steel
over pre-painted primer. The pre-treated flat galvanized steel
provides a better paint to steel bond, which resists corrosion
and rust creep. Special primer formulas and glossy earth tone
finish insure less fading when exposed to sunlight. This finish
has been tested to provide 1/3 greater protection than conventional units.
PROTECTED COMPRESSORS - The Twin Single™ compressor is protected against high pressure. Hard start components
are included to ensure start-up under adverse conditions. All
models have standard crankcase heat for added protection.
OPTIMUM PERFORMANCE - The solid-state electronic controlboard optimizes the compressor staging based on load
requirements, provides a 5-minute anti-short cycle timer, and
simplifies troubleshooting with built in self diagnostics.
LOWER INSTALLED COST - Installation time and costs are
reduced by easy power and control wiring connections. All
units contain enough refrigerant for the smallest matching
indoor coil and 15 feet of interconnecting piping. The small
base dimension means less space is required on the ground or
roof.
EFFECTIVE HUMIDITY CONTROL - The inherent design of
the Stealth system and the staging operation of the Twin Single™ compressor provide effective humidity control at the lowest possible operating cost. An optional dehumidification
control accessory is available to maintain the humidity at a set
desired level.
TOP DISCHARGE - The warm air from the top mounted fan is
blown up away from the structure and any landscaping. This
allows compact location on multi-unit applications.
LOW OPERATING SOUND LEVEL - The upward air flow carries the normal operating noise up away from the living area.
The rigid top panel effectively isolates any motor sound. Isolator mounted compressor and the rippled fins of the condenser
coil muffle the normal fan motor and compressor operating
sounds.
LOW MAINTENANCE - Long life permanently lubricated
motor- bearings need no annual servicing.
EASY SERVICE ACCESS - Fully exposed refrigerant connections and a single panel covering the electrical controls make
servicing easy. Easy access for coil clearing is also provided.
RE-USABLE SERVICE VALVES - Provided on both the liquid
and vapor sweat connections for ease of evacuating and
charging.
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
036-21342-002 Rev. E (0505)
SYSTEM OPERATION
4.
This heat pump model is equipped with both YorkGuard V
heat pump control and TS compressor control. The interface
control 6CF board is used to bypass the first stage of heat
when the outdoor temperature falls below certain temperatures. The TS control board is used only to switch between 1
and 2 cylinder operation. The fault codes and pressure switch
on the TS control board are bypassed using the jumpers
between the test and "PS" pins.
1.
2.
3.
Anti-short Cycle Timer
The five-minute time delay on YorkGuard V will be used
to prevent the system from short cycling after the thermostat off or power interrupt. This time delay can be
bypassed by temporarily shorting the test terminals on
YorkGuard V for 3 seconds. Since a jumper was factory
installed across the test pins on the TS control board, the
anti-short cycle timer on the TS control board is
bypassed.
First Stage Cooling
This heat pump model is equipped with a Twin-Single
compressor. With a call for first stage cooling, the compressor operates one cylinder. The run winding (R) is
connected through the upper left contactor (A) and to the
capacitor and the start winding (S) is connected to line
voltage. The system operates at low discharge pressure
and high suction pressure.
Second Stage of Cooling
With a call for second stage cooling, the TS control will
shut the compressor off for two seconds then energize
relays R1 and R2 on the TS control board. This will deenergize (open) the upper left contactor (A) and energize
(close) the lower right contactor (B), connecting the compressor run winding (R) to the line voltage and start
winding (S) to the capacitor. The compressor runs in the
reverse direction with two cylinders compared to the first
stage. The system will operate with two cylinders until
both first and second stage are satisfied. The Y2OUT
signal from the relay board causes the indoor blower to
function at high speed.
6K Relay on the 6CF Control Board
The 6K relay on the 6CF interface board operates as follows. See Figure 1:
a.
If the YorkGuard V defrost control balance point setting is 45°F, the 6K relay will be:
• Energized if liquid temperature goes below 35°F.
• De-energized if the liquid temperature goes above
35°F AND the ambient is greater than 42°F for five
minutes AND the unit is not in defrost.
b.
If the YorkGuard V defrost control balance point setting is at anything but 45°F, the 6K relay will be:
• Energized if liquid temperature goes below 45°F.
• De-energized if the liquid temperature goes above
45°F AND the ambient is greater than 55°F AND
the unit is not in defrost.
5.
Heating mode with the de-energized 6K relay
The TS compressor operates similar to the first and second stage of cooling modes except there is no O input
from the thermostat, the reversing valve is not energized,
and the system operates in heating heat pump mode.
The YorkGuard V control and the liquid temperature will
not allow the system to go into the defrost mode.
6.
Heating mode with the energized 6K Relay
The energized 6K relay on the interface board (6CF) will
connect Y1 and Y2 and disconnect Y2OUT from the TS
control to the indoor blower if the J1 pin is not in the ON
position. The compressor will operate only in second
stage regardless of the first or second stage call from the
thermostat. The indoor blower will operate in low air
mode. The indoor discharge air temperature should be
about 10°F hotter than a normal heat pump. If highspeed air is preferred, move J1 pin to the ON position at
the interface board (6CF). This will send the Y2OUT signal back to the indoor blower for the high speed air.
Y2
If the room thermostat calls for second stage cooling
(Y2) on two consecutive cooling cycles, the next call for
cooling for either first or second stage will energize the
unit in second stage mode. The above mode will be reset
to permit start up on the first stage with only a Y1 call
when the second stage operation cycle runs less than 15
minutes or when 24V to the TS control board is disconnected.
Y2 OUT
6K
24V (R) FROM
YORKGUARD
6K
NC
NC
J1
6K
NO
R
Y2
Y1
Y2 OUT
FIGURE 1 : 6CF Interface Board
2
Unitary Products Group
036-21342-002 Rev. E (0505)
Physical and Electrical Data
MODEL
E4TS030
E4TS036
UNIT SUPPLY VOLTAGE
E4TS048
E4TS060
208/230-1-60
NORMAL VOLTAGE RANGE 1
187 to 252
MIN. CIRCUIT AMPACITY
14.8
2
34.4
25
30
50
60
T27B355CBCA
T29A464BBCA
T29A544BBCA
RATED LOAD
11.3
14.1
21.2
26.3
LOCKED ROTOR
65
84
130
142
CRANKCASE HEATER
FAN MOTOR AMPS
YES
YES
YES
YES
RATED LOAD
.7
.7
1.5
1.5
24
24
24
24
RATED HP
1/10
1/10
1/4
1/4
FAN DIAMETER INCHES
FAN MOTOR
28.0
T27B264CBCA
MAX. OVERCURRENT DEVICE AMPS
COMPRESSOR TYPE
COMPRESSOR AMPS
18.3
NOMINAL RPM
825
825
825
850
NOMINAL CFM
2650
2650
3200
3200
FACE AREA SQ. FT.
20.0
20.0
20.0
20.0
ROWS DEEP
1
1
2
2
COIL
FIN / INCH
LIQUID LINE OD
VAPOR LINE OD
3
16
16
13
13
3/8
3/8
3/8
3/8
7/8
7/8
7/8
7/8
9-9
10 - 1
12 - 1
13 - 1
CHARGE PER FOOT, OZ
.70
.70
.70
.70
OPERATING WEIGHT LBS.
242
242
310
310
UNIT CHARGE, (LBS - OZ)
1. Rated in accordance with ARI Standard 110, utilizaton range “A”.
2. Dual element fuses or HACR circuit breaker.
3. The Unit Charge is correct for the outdoor unit, matched indoor coil and 15 feet of refrigerant tubing. For tubing lengths other than
15 feet, add or subtract the amount of refrigerant calculated, using the difference in length multiplied by the per foot value.
All dimensions are in inches. They are subject to change without
notice. Certified dimensions will be provided upon request.
48" OVERHEAD
CLEARANCE
C
B
UNIT
MODEL
E4TS
AIR IN
4 SIDES
A
030
036
048
060
REFRIGERANT
CONNECTION
LINE SIZE
DIMENSIONS
A
31-7/8
31-7/8
31-7/8
37-7/8
B
35
35
35
35
C
35
35
35
35
LIQUID
VAPOR
3/8
7/8
5-1/2
VAPOR
CONNECTION
2-3/8
LIQUID CONNECTION
3-1/8
Unitary Products Group
3
036-21342-002 Rev. E (0505)
Additional R-22 Charge / Orifice Size for Various Matched Systems
OUTDOOR UNIT
E4TS030
UNIT ORIFICE(S)**
FACTORY CHARGE, LBS. - OZ.
INDOOR COIL
COIL ORIFICE1
E4TS036
E4TS048
E4TS060
—
—
—
—
9-9
10 - 1
12 - 1
13 - 1
REQUIRED SYSTEM EXPANSION DEVICE + ADDITIONAL CHARGE, OZ.
G1FA/G1UA048S17,21
78
701 + 0
702 + 0
—
—
G1FA/G1UA060S21,24
84
—
702 + 10
703 + 0
703 + 0
G1FA060S21,24T
84
—
—
703 + 0
703 + 0
G2FD046(S,H)17
78
701 + 0
702 + 0
—
—
G2FD042(S,H)21
78
701 + 0
—
—
—
G2FD048(S,H)21, 24
84
701 + 6
702 + 0
—
—
G2FD060(S,H)24
90
—
702 + 10
703 + 0
703 + 0
G2FD060H24T
90
—
—
703 + 0
703 + 0
G2FD061H24
90
—
—
703 + 8
703 + 4
.70
.70
.70
.70
—
—
—
REFRIGERANT LINE ADDER OZ. / FT.
Airflow
VARIABLE SPEED INDOOR
N1VSB12
Hi/Low CFM
1050/630
N1VSC16
Hi/Low CFM
1065/650
1185/770
—
—
N1VSD20
Hi/Low CFM
—
1200/780
1605/1040
1860/1200
P1XDB12V075
Hi/Low CFM
1040/580
1220/690
—
—
P1XUB12V055
Hi/Low CFM
1020/570
1200/660
—
—
P1DUB16V080
Hi/Low CFM
1050/540
1200/650
—
—
P1XUC16V075
Hi/Low CFM
1000/550
1200/650
1605/880
—
P1DUC20V080
Hi/Low CFM
—
1220/660
1620/900
1870/1030
P1DUC20V096
Hi/Low CFM
—
1200/650
1610/900
1850/1080
P1XUC20V095
Hi/Low CFM
—
1200/630
1590/850
1880/1000
P1XUD20V112
Hi/Low CFM
—
1260/720
1620/920
1800/990
P1XDD20V112
Hi/Low CFM
—
1200/690
1610/850
1870/1010
F(2,3)FV060
Hi/Low CFM
—
—
1600/1040
1875/1200
Hi CFM
—
1000
1200
1600
1900
Max Low CFM
—
850
1000
1350
1600
Recommended Low CFM
—
600
750
900
1050
1. Unit factory charge listed on the unit nameplate includes refrigerant for the condensor, the smallest evaporator and for 15 feet of
interconnecting line tubing.
2. Verify the TXV kit and the additional charge required for the specific evaporator coil in the system using the table above.
3. Add additional charge for the amount of interconnecting line tubing greater than 15 feet at the rate specified in the table above.
4. Permanently mark the unit nameplate with the total system charge.
5. Total System Charge = Base charge (as shipped) + adder for evaporator + adder for line set.
4
Unitary Products Group
036-21342-002 Rev. E (0505)
COOLING CAPACITY - Variable Speed Air Handler
UNIT
MODEL
N1VS AIR HANDLER
ELECTRIC
MODEL
HEAT KW 2
1
W
N1VSB12
5,7.5,10,15,18
17
N1VSC16
5,7.5,10,15,20
21
COIL MODEL
STAGE
(# CYL)
RATED
CFM
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
630
1050
650
1065
650
1065
770
1185
780
1200
1040
1600
1040
1605
1040
1605
1220
1875
1200
1860
1200
1860
G2FD046S17
G2FD042S21
E4TS030
G2FD048S21
N1VSC16
5,7.5,10,15,20
21
G2FD048S21
N1VSD20
7.5,10,15,20,25,30
24
G2FD048S24
F(2,3)FV060
10,15,20,25
N1VSD20
7.5,10,15,20,25,30
E4TS036
–
E4TS048
24
G2FD060S24
G2FD061H24
F(2,3)FV060
10,15,20,25
–
N1VSD20
7.5,10,15,20,25,30
E4TS060
24
G2FD060S24
G2FD061H24
COOLING
NET MBH
SEER
TOTAL SENS.
15200
29000
15000
28600
15800
30000
21400
36000
21600
36400
26800
48000
26800
48000
27400
49000
27800
55500
27800
55500
29000
57000
12200
21400
12000
21000
12600
22000
15400
25600
15600
26000
21800
35600
21800
35600
22200
36400
23400
40500
23400
40500
24000
41500
EER
13.7
12.0
13.6
11.9
13.9
12.1
13.3
11.6
13.6
11.8
13.6
11.4
13.6
11.4
13.8
11.6
13.2
10.4
13.2
10.4
13.4
10.6
15.5
15.4
15.7
15.0
15.2
15.0
15.0
15.2
14.5
14.5
14.7
1. G2FD coils available with a factory installed horizontal drain pan. See price pages for specific model number.
2. Single phase units require single phase 2HK heaters.
COOLING CAPACITY - Variable Speed Furnace
COOLING
UNIT
MODEL
VARIABLE SPEED
FURNACE MODEL
W
COIL MODEL
P1XDB12V
17
G2FD046S17
G2FD046S17
P1XUB12V
17
G1UA048S17
G1FA048S17
G2FD046S17
E4TS030
P1DUB16V
17
G1UA048S17
G1FA048S17
G2FD042S21
G1UA048S21
P1XUC16V
21
G1FA048S21
G2FD048S21
STAGE
(# CYL)
RATED
CFM
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
580
1040
570
1020
570
1020
570
1020
540
1050
540
1050
540
1050
600
1100
600
1100
600
1100
600
1100
NET MBH1
TOTAL SENS.
13800
28200
13800
28000
13800
28000
13800
28000
13600
28200
13600
28200
13600
28200
13600
28000
13800
28800
13800
28800
14200
29000
10400
20800
10400
20600
10400
20600
10400
20600
10200
20800
10200
20800
10200
20800
10400
20600
10600
21400
10600
21400
10800
21400
SEER2
EER3
13.3
11.6
13.3
11.6
13.3
11.6
13.3
11.6
13.4
11.7
13.4
11.7
13.4
11.7
13.2
11.4
13.6
11.6
13.6
11.6
13.7
11.8
15.0
15.0
15.0
15.0
15.0
15.0
15.0
14.8
15.2
15.2
15.3
For notes see Page 7.
Unitary Products Group
5
036-21342-002 Rev. E (0505)
COOLING CAPACITY - Variable Speed Furnace (Continued)
COOLING
UNIT
MODEL
VARIABLE SPEED
FURNACE MODEL
W
COIL MODEL
P1XDB12V
17
G2FD046S17
G2FD046S17
P1XUB12V
17
G1UA048S17
G1FA048S17
G2FD046S17
P1DUB16V
17
G1UA048S17
E4TS036
G1FA048S17
G1UA048S21
G1FA048S21
P1XUC16V
21
G2FD048S21
G1UA060S21
G1FA060S21
G1UA048S21
G1FA048S21
P1DUC20V
21
G2FD048S21
G1UA060S21
G1FA060S21
G1UA048S21
G1FA048S21
P1XUC20V
21
G2FD048S21
E4TS036
G1UA060S21
G1FA060S21
P1XDD20V
24
G2FD048S24
G1UA048S24
G1FA048S24
P1XUD20V
24
G2FD048S24
G1UA060S24
G1FA060S24
STAGE
(# CYL)
RATED
CFM
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
690
1220
660
1200
660
1200
660
1200
650
1200
650
1200
650
1200
640
1200
640
1200
640
1200
640
1200
640
1200
640
1200
640
1200
640
1200
640
1200
640
1200
625
1200
625
1200
625
1200
625
1200
625
1200
690
1200
715
1260
715
1260
715
1260
715
1260
715
1260
NET MBH1
TOTAL SENS.
20000
35600
19800
35400
19800
35400
19800
35400
20000
35600
20000
35600
20000
35600
20200
35800
20200
35800
20400
36000
21000
37000
21000
37000
20200
35800
20200
35800
20400
36000
21000
37000
21000
37000
20000
35600
20000
35600
20200
35800
20800
36800
20800
36800
20400
36000
20600
36200
20600
36200
20800
36400
21400
37400
21400
37400
15200
25800
15000
25600
15000
25600
15000
25600
15000
25600
15000
25600
15000
25600
15200
25800
15200
25800
15400
26000
15800
26600
15800
26600
15200
25800
15200
25800
15400
26000
15800
26600
15800
26600
15000
25600
15000
25600
15200
25800
15600
26400
15600
26400
16200
27400
16000
27200
16000
27200
16200
27400
16600
28000
16600
28000
SEER2
14.0
14.0
14.0
14.0
14.0
14.0
14.0
14.0
14.0
14.0
14.4
14.4
14.1
14.1
14.3
14.6
14.6
14.0
14.0
14.2
14.5
14.5
14.5
14.2
14.2
14.5
14.8
14.8
For notes see Page 7.
6
Unitary Products Group
EER3
12.4
10.8
12.5
11.0
12.5
11.0
12.5
11.0
12.6
11.0
12.6
11.0
12.6
11.0
12.5
11.1
12.5
11.1
12.6
11.1
13.0
11.3
13.0
11.3
12.5
11.2
12.5
11.2
12.8
11.3
13.1
11.4
13.1
11.4
12.6
11.0
12.6
11.0
12.7
11.2
13.0
11.3
13.0
11.3
12.9
11.3
12.8
11.2
12.8
11.2
13.0
11.4
13.3
11.6
13.3
11.6
036-21342-002 Rev. E (0505)
COOLING CAPACITY - Variable Speed Furnace (Continued)
COOLING
UNIT
MODEL
VARIABLE SPEED
FURNACE MODEL
W
COIL MODEL
G1UA060S21
P1XUC16V
21
G1UA060S21
G1UA060S21
P1DUC20V
21
G1FA060S21
E4TS048
G1UA060S21
P1XUC20V
21
G1FA060S21
G2FD060S24
P1XDD20V
24
G2FD061H24
G1UA060S24
G1FA060S24
E4TS048
P1XUD20V
24
G2FD060S24
G2FD061H24
G2FD060S24
P1XDD20V
24
G2FD061H24
G1UA060S24
E4TS060
G1FA060S24
P1XUD20V
24
G2FD060S24
G2FD061H24
STAGE
(# CYL)
RATED
CFM
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
880
1600
880
1600
900
1610
900
1610
850
1590
850
1590
880
1580
880
1580
915
1620
915
1620
915
1620
915
1620
1000
1800
1000
1800
990
1800
990
1800
990
1800
990
1800
NET MBH1
TOTAL SENS.
23800
47000
23800
47000
24200
47500
24200
47500
23600
47000
23600
47000
24400
47500
24800
48500
24800
48000
24800
48000
24800
48000
25200
49000
27000
55000
28000
56000
27000
55500
27000
55500
27000
55500
28000
56500
17600
33800
17600
33800
18000
34200
18000
34200
17400
33800
17400
33800
18400
34200
18800
34800
18800
34600
18800
34600
18800
34600
19200
35200
20400
39600
20800
40000
20400
40000
20400
40000
20400
40000
20800
40500
SEER2
EER3
12.6
10.8
12.6
10.8
12.6
10.9
12.6
10.9
12.6
10.8
12.6
10.8
12.5
11.0
12.7
11.2
12.7
11.0
12.7
11.0
12.7
11.0
12.9
11.3
12.6
10.0
12.8
10.2
12.5
10.2
12.5
10.2
12.5
10.2
12.8
10.4
14.0
14.0
14.0
14.0
14.0
14.0
14.0
14.4
14.2
14.2
14.2
14.5
13.7
14.0
13.8
13.8
13.8
14.0
1. Cooling MBH based on 80° F entering air temperature, 50% RH and rated airflow.
2. SEER (Seasonal Energy Efficiency Ratio) equals the total cooling output in BTU’s during a normal annual usage period for cooling divided by the total electric power input in watt-hours during the same period. Normal annual usage is a combination of both
one and two cylinder operating periods.
3. EER (Energy Efficiency Ratio) equals the total cooling output in BTU’s at 95° F outdoor ambient divided by the total electric power
in watt-hours at those conditions.
Unitary Products Group
7
036-21342-002 Rev. E (0505)
HEATING CAPACITY - Variable Speed Air Handler
UNIT
MODEL
N1VS AIR HANDLER
ELECTRIC
MODEL
HEAT KW 2
W
N1VSB12
5,7.5,10,15,18
17
N1VSC16
5,7.5,10,15,20
21
E4TS030
COIL MODEL1 STAGE
(# CYL)
G2FD046S17
G2FD042S21
G2FD048S21
N1VSC16
5,7.5,10,15,20
21
G2FD048S21
N1VSD20
7.5,10,15,20,25,30
24
G2FD048S24
F(2,3)FV060
10,15,20,25
E4TS036
E4TS048
–
24
N1VSD20
G2FD060S24
7.5,10,15,20,25,30
G2FD061H24
F(2,3)FV060
10,15,20,25
N1VSD20
7.5,10,15,20,25,30
E4TS060
–
24
G2FD060S24
G2FD061H24
1
2
2
1
2
2
1
2
2
1
2
2
1
2
2
1
2
2
1
2
2
1
2
2
1
2
2
1
2
2
1
2
2
RATED
CFM
630
630
1050
650
650
1065
650
650
1065
770
770
1185
780
780
1200
1040
1040
1600
1040
1040
1605
1040
1040
1605
1220
1220
1875
1200
1200
1860
1200
1200
1860
HEATING
NET MBH
47 OD
17 OD
13400
24600
26400
13200
24200
26000
13800
24800
27000
19600
31600
35000
20000
32000
35600
23800
43500
47000
23800
43500
47000
24200
44500
48000
25800
51000
54000
25800
51000
54000
26600
50500
55000
–
14400
15400
–
14200
15200
–
14800
16000
–
19000
20800
–
19200
21200
–
24800
26400
–
24800
26400
–
25600
27000
–
26400
28600
–
26400
28600
–
26800
29200
HSPF COP@ 47
–
8.7
9.0
–
8.7
9.0
–
8.9
9.2
–
8.7
9.2
–
8.8
9.3
–
8.2
8.5
–
8.2
8.5
8.4
8.7
–
8.1
8.5
–
8.1
8.5
–
8.3
8.7
1. G2FD coils available with a factory installed horizontal drain pan. See price pages for specific model number.
2. Single phase units require single phase 2HK heaters.
8
Unitary Products Group
3.80
3.48
3.60
3.80
3.46
3.58
3.88
3.52
3.64
3.78
3.52
3.54
3.86
3.62
3.74
3.66
3.50
3.58
3.66
3.50
3.58
3.72
3.58
3.66
3.58
3.32
3.44
3.58
3.32
3.44
3.64
3.38
3.50
036-21342-002 Rev. E (0505)
HEATING CAPACITY - Variable Speed Furnace
HEATING
UNIT
MODEL
VARIABLE SPEED
FURNACE MODEL
W
COIL MODEL
P1XDB12V075
17
G2FD046S17
G2FD046S17
P1XUB12V055
17
G1UA048S17
G1FA048S17
G2FD046S17
E4TS030
P1DUB16V080
17
G1UA048S17
G1FA048S17
G2FD042S21
G1UA048S21
P1XUC16V075
21
G1FA048S21
G2FD048S21
P1XDB12V075
17
G2FD046S17
17
G2FD046S17
E4TS036
P1XUB12V055
G1UA048S17
G1FA048S17
STAGE RATED
(# CYL) CFM
1
2
2
1
2
2
1
2
2
1
2
2
1
2
2
1
2
2
1
2
2
1
2
2
1
2
2
1
2
2
1
2
2
1
2
2
1
2
2
1
2
2
1
2
2
580
580
1040
570
570
1020
570
570
1020
570
570
1020
540
540
1050
540
540
1050
540
540
1050
600
600
1100
600
600
1100
600
600
1100
600
600
1100
690
690
1220
660
660
1200
660
660
1200
660
660
1200
NET MBH 1,2
47 OD
17 OD
12800
24000
26200
12800
23800
26000
12800
23800
26000
12800
23800
26000
12400
24200
26400
12400
24200
26400
12400
24200
26400
13000
24800
27000
13200
25200
27400
13200
25200
27400
13400
25400
27600
17400
31000
34600
17200
31000
34600
17400
31400
35000
17400
31400
35000
14000
15200
13800
15000
13800
15000
13800
15000
14200
15400
14200
15400
14200
15400
14600
15800
15000
16400
15000
16400
15200
16600
18400
20600
18400
20600
18400
20800
18600
20800
HSPF3 COP4 @ 47 F
8.3
8.6
8.3
8.6
8.3
8.6
8.3
8.6
8.3
8.6
8.3
8.6
8.3
8.6
8.4
8.7
8.5
8.8
8.5
8.8
8.6
8.9
7.9
8.3
8.0
8.4
8.0
8.4
8.0
8.4
3.58
3.38
3.56
3.58
3.34
3.52
3.58
3.34
3.52
3.58
3.34
3.52
3.54
3.39
3.58
3.54
3.39
3.58
3.54
3.39
3.58
3.70
3.46
3.64
3.72
3.50
3.68
3.72
3.50
3.68
3.76
3.50
3.68
3.56
3.26
3.52
3.54
3.30
3.56
3.58
3.32
3.58
3.58
3.32
3.58
For notes see Page 12.
Unitary Products Group
9
036-21342-002 Rev. E (0505)
HEATING CAPACITY - Variable Speed Furnace (Continued)
HEATING
UNIT
MODEL
VARIABLE SPEED
FURNACE MODEL
W
COIL MODEL
G2FD046S17
P1DUB16V080
17
G1UA048S17
G1FA048S17
G1UA048S21
G1FA048S21
P1XUC16V075
21
G2FD048S21
G1UA060S21
G1FA060S21
G1UA048S21
E4TS036
G1FA048S21
P1DUC20V080
21
G2FD048S21
G1UA060S21
G1FA060S21
G1UA048S21
G1FA048S21
P1DUC20V096
21
G2FD048S21
G1UA060S21
G1FA060S21
STAGE RATED
(# CYL) CFM
1
2
2
1
2
2
1
2
2
1
2
2
1
2
2
1
2
2
1
2
2
1
2
2
1
2
2
1
2
2
1
2
2
1
2
2
1
2
2
1
2
2
1
2
2
1
2
2
1
2
2
1
2
2
650
650
1200
650
650
1200
650
650
1200
640
640
1200
640
640
1200
640
640
1200
640
640
1200
640
640
1200
650
650
1220
650
650
1220
650
650
1220
650
650
1220
650
650
1220
640
640
1200
640
640
1200
640
640
1200
640
640
1200
640
640
1200
NET MBH 1,2
47 OD
17 OD
17000
31000
34600
17200
31400
35000
17200
31400
35000
17000
31600
35200
17000
31600
35200
17200
32000
35600
17600
32400
36000
17600
32400
36000
17200
32400
36000
17200
32400
36000
17400
32600
36200
18000
33000
36600
18000
33000
36600
17000
31800
35400
17000
31800
35400
17200
32000
35600
17600
32600
36200
17600
32600
36200
18400
20600
18600
20800
18600
20800
18800
21000
18800
21000
19000
21200
19400
21600
19400
21600
19000
21200
19000
21200
19400
21600
19800
22000
19800
22000
18800
21000
18800
21000
19000
21200
19400
21600
19400
21600
HSPF3 COP4 @ 47 F
8.0
8.4
8.0
8.4
8.0
8.4
8.0
8.4
8.0
8.4
8.1
8.5
8.4
8.7
8.4
8.7
8.1
8.5
8.1
8.5
8.2
8.6
8.5
8.8
8.5
8.8
8.0
8.4
8.0
8.4
8.1
8.5
8.4
8.7
8.4
8.7
For notes see Page 12.
10
Unitary Products Group
3.54
3.30
3.56
3.58
3.32
3.58
3.58
3.32
3.58
3.54
3.36
3.62
3.54
3.36
3.62
3.56
3.40
3.66
3.60
3.48
3.74
3.60
3.48
3.74
3.52
3.44
3.70
3.52
3.44
3.70
3.54
3.48
3.74
3.60
3.52
3.78
3.60
3.52
3.78
3.54
3.36
3.62
3.54
3.36
3.62
3.56
3.40
3.66
3.60
3.48
3.74
3.60
3.48
3.74
036-21342-002 Rev. E (0505)
HEATING CAPACITY - Variable Speed Furnace (Continued)
HEATING
UNIT
MODEL
VARIABLE SPEED
FURNACE MODEL
W
COIL MODEL
G1UA048S21
G1FA048S21
P1XUC20V095
21
G2FD048S21
G1UA060S21
G1FA060S21
E4TS036
P1XDD20V112
G2FD048S24
G1UA048S24
G1FA048S24
P1XUD20V112
24
G2FD048S24
G1UA060S24
G1FA060S24
G1UA060S21
P1XUC16V075
21
G1FA060S21
G1UA060S21
P1DUC20V080
21
G1FA060S21
E4TS048
G1UA060S21
P1DUC20V096
21
G1FA060S21
G1UA060S21
P1XUC20V095
21
G1FA060S21
STAGE RATED
(# CYL) CFM
1
2
2
1
2
2
1
2
2
1
2
2
1
2
2
1
2
2
1
2
2
1
2
2
1
2
2
1
2
2
1
2
2
1
2
2
1
2
2
1
2
2
1
2
2
1
2
2
1
2
2
1
2
2
1
2
2
625
625
1200
625
625
1200
625
625
1200
625
625
1200
625
625
1200
690
690
1200
715
715
1260
715
715
1260
715
715
1260
715
715
1260
715
715
1260
880
880
1600
880
880
1600
890
890
1620
890
890
1620
900
900
1610
900
900
1610
850
850
1590
850
850
1590
NET MBH 1,2
47 OD
17 OD
16600
31800
35400
16600
31800
35400
16800
32000
35600
17200
32600
36200
17200
32600
36200
18000
32000
35600
18000
32600
36200
18000
32600
36200
18200
32800
36400
18800
33400
37000
18800
33400
37000
20800
43500
47000
20800
43500
47000
21000
43500
47000
21000
43500
47000
21400
43500
47000
21400
43500
47000
20200
43000
46500
20200
43000
46500
18800
21000
18800
21000
19000
21200
19400
21600
19400
21600
19000
21200
19600
21800
19600
21800
19800
22000
20200
22400
20200
22400
24200
26200
24200
26200
24400
26400
24400
26400
24200
26200
24200
26200
23800
25800
23800
25800
HSPF3 COP4 @ 47 F
7.9
8.3
7.9
8.3
8.0
8.4
8.3
8.6
8.3
8.6
8.4
8.7
8.3
8.7
8.3
8.7
8.4
8.8
8.7
9.0
8.7
9.0
7.7
8.0
7.7
8.0
7.8
8.1
7.8
8.1
7.8
8.1
7.8
8.1
7.6
7.9
7.6
7.9
3.48
3.34
3.60
3.48
3.34
3.60
3.52
3.38
3.64
3.58
3.44
3.70
3.58
3.44
3.70
3.56
3.54
3.80
3.52
3.54
3.80
3.52
3.54
3.80
3.56
3.56
3.82
3.64
3.64
3.90
3.64
3.64
3.90
3.24
3.36
3.54
3.24
3.36
3.54
3.28
3.44
3.62
3.28
3.44
3.62
3.32
3.42
3.60
3.32
3.42
3.60
3.20
3.36
3.54
3.20
3.36
3.54
For notes see Page 12.
Unitary Products Group
11
036-21342-002 Rev. E (0505)
HEATING CAPACITY - Variable Speed Furnace (Continued)
HEATING
UNIT
MODEL
VARIABLE SPEED
FURNACE MODEL
W
COIL MODEL
G2FD060S24
P1XDD20V112
G2FD061H24
G1UA060S24
E4TS048
G1FA060S24
P1XUD20V112
24
G2FD060S24
G2FD061H24
G2FD060S24
P1XDD20V112
G2FD061H24
G1UA060S24
E4TS060
G1FA060S24
P1XUD20V112
24
G2FD060S24
G2FD061H24
STAGE RATED
(# CYL) CFM
1
2
2
1
2
2
1
2
2
1
2
2
1
2
2
1
2
2
1
2
2
1
2
2
1
2
2
1
2
2
1
2
2
1
2
2
880
880
1580
880
880
1580
915
915
1620
915
915
1620
915
915
1620
915
915
1620
1000
1000
1800
1000
1000
1800
990
990
1800
990
990
1800
990
990
1800
990
990
1800
NET MBH 1,2
47 OD
17 OD
21400
43000
46500
22000
44000
47500
22200
44000
47500
22200
44000
47500
22200
44000
47500
22600
45000
48500
23400
49500
54000
23400
50500
55000
23200
49500
54000
23200
49500
54000
23200
49500
54000
23200
50500
55000
23800
25800
24400
26400
25000
27000
25000
27000
25000
27000
25600
27600
26000
28400
26600
29000
26000
28400
26000
28400
26000
28400
26600
29000
HSPF3 COP4 @ 47 F
7.7
8.0
7.9
8.2
7.8
8.1
7.8
8.1
7.8
8.1
8.0
8.3
7.5
7.9
7.9
8.2
7.6
8.0
7.6
8.0
7.6
8.0
8.0
8.3
3.30
3.34
3.52
3.38
3.42
3.60
3.34
3.36
3.54
3.34
3.36
3.54
3.34
3.36
3.54
3.40
3.44
3.62
3.38
3.28
3.46
3.48
3.35
3.52
3.34
3.34
3.52
3.34
3.34
3.52
3.34
3.34
3.52
3.42
3.40
3.58
1. Heating MBH based on ARI standards of 70° DB entering indoor air, 72% RH outdoor air with 25 feet of interconnecting piping and
no supplemental electric heat operation.
2. Integrated heating capacities include the effect of defrost cycles in the temperature range where they occur.
3. HSPF (Heating Seasonal Performance Factor) is the total heating output during a normal annual usage period for heating divided
by the total electric power input during the same period.
4. COP equals MBH output divided by (total KW input x 3.412).
ACCESSORIES
Refer to Price Manual for specific model numbers.
TXV Kit - Factory specified and required for proper unit performance.
E4TS030 = 1TV0701
E4TS036 = 1TV0702
E4TS048 = 1TV0703
E4TS060 = 1TV0703
Room Thermostat - Matching 2-Stage cooling thermostats
are available to provide features required for any installation.
See list below:
2ET03700624 - Honeywell Programmable
2ET03700524 - Honeywell Non-Programmable
2EP32U70124 - White Rodgers Programmable
12
Dehumidification Control - Model 2HU06700124 available
for use in areas where a higher level of humidity control is
required.
Fossil Fuel Relay (Model 2FF02700101) - Required for use
with all furnace applications.
SOUND RATINGS*
SOUND RATINGS
(dba)
UNIT MODEL
1 CYLINDER
2 CYLINDER
030
72
73
036
75
78
048
77
79
060
79
81
* Rated in accordance with ARI 270-95 Standards.
Unitary Products Group
036-21342-002 Rev. E (0505)
COOLING PERFORMANCE DATA
E4TS030S06A WITH N1VSC1606 / G2FD048S21 - HIGH CFM 2-CYLINDER OPERATION
ID CFM
CONDENSER
ENTERING AIR ID DB (°F)
TEMPERATURE ID WB (°F)
T.C.
75
S.C.
K.W.
T.C.
85
S.C.
K.W.
T.C.
95
S.C.
K.W.
T.C.
105
S.C.
K.W.
T.C.
115
S.C.
K.W.
T.C.
125
S.C.
K.W.
80
72
35.72
16.87
2.13
33.76
16.34
2.32
31.81
15.81
2.51
29.85
15.28
2.70
27.96
14.77
2.88
26.06
14.25
3.06
80
67
32.39
21.50
2.11
30.76
21.18
2.27
29.13
20.86
2.43
27.50
20.53
2.59
25.92
20.22
2.75
24.33
19.90
2.90
980
80
62
29.01
26.90
2.07
27.81
26.05
2.21
26.61
25.21
2.36
25.40
24.36
2.51
24.24
23.53
2.65
23.07
22.71
2.79
75
62
29.01
21.61
2.07
27.81
20.76
2.21
26.61
19.91
2.36
25.40
19.06
2.51
24.24
18.24
2.65
23.07
17.41
2.79
80
57
27.74
26.84
2.00
27.15
25.72
2.17
25.99
24.61
2.32
24.27
23.49
2.45
23.58
22.41
2.60
22.40
21.32
2.77
80
72
36.45
17.73
2.19
34.33
17.09
2.38
32.20
16.46
2.56
30.08
15.82
2.74
28.02
15.20
2.92
25.96
14.58
3.09
80
67
33.78
23.46
2.19
31.89
22.72
2.34
30.00
22.22
2.49
28.11
21.61
2.64
26.27
21.00
2.79
24.43
20.40
2.94
1065
80
62
30.89
29.75
2.12
29.38
28.08
2.27
27.87
27.01
2.42
26.37
25.64
2.57
24.90
24.31
2.72
23.43
22.98
2.86
75
62
30.89
24.46
2.12
29.38
22.84
2.27
27.87
21.72
2.42
26.37
20.35
2.57
24.90
19.02
2.72
23.43
17.69
2.86
80
57
28.07
27.62
2.01
28.08
27.37
2.21
27.06
26.37
2.38
25.00
24.61
2.51
24.03
23.44
2.68
22.90
22.37
2.85
80
72
37.18
18.59
2.26
34.89
17.84
2.44
32.60
17.10
2.61
30.31
16.36
2.78
28.09
15.63
2.95
25.86
14.91
3.12
80
67
35.17
25.42
2.26
33.02
24.26
2.40
30.87
23.59
2.55
28.71
22.68
2.69
26.62
21.79
2.83
24.53
20.90
2.97
1210
80
62
32.78
32.61
2.17
30.96
30.10
2.33
29.14
28.82
2.48
27.33
26.93
2.63
25.56
25.09
2.78
23.80
23.26
2.93
75
62
32.78
27.31
2.17
30.96
24.91
2.33
29.14
23.53
2.48
27.33
21.64
2.63
25.56
19.80
2.78
23.80
17.97
2.93
80
57
28.39
28.39
2.01
29.01
29.01
2.24
28.13
28.13
2.43
25.73
25.73
2.57
24.47
24.47
2.76
23.41
23.41
2.92
80
72
19.90
10.13
1.02
18.83
9.90
1.10
17.75
9.68
1.20
80
67
18.81
13.95
1.01
17.65
13.22
1.08
16.48
12.49
1.19
770
80
62
18.17
15.46
0.99
17.12
14.62
1.07
16.06
13.79
1.17
75
62
18.17
10.54
0.99
17.12
9.71
1.07
16.06
8.87
1.17
80
57
17.98
17.98
0.98
16.84
16.84
1.06
15.97
15.97
1.15
E4TS030S06A WITH N1VSC1606 / G2FD048S21 - LOW CFM 1-CYLINDER OPERATION
ID CFM
650
720
CONDENSER
80
80
80
75
80
80
80
80
75
80
ENTERING AIR ID DB (°F)
TEMPERATURE ID WB (°F) 72
67
62
62
57
72
67
62
62
57
T.C.
19.20 18.62 17.94 17.94 17.75 19.55 18.71 18.06 18.06 17.86
75
S.C.
9.57 13.15 15.71 10.79 17.10 9.85 13.55 15.58 10.66 17.54
K.W.
0.99 0.98 0.97 0.97 0.95 1.01 0.99 0.98 0.98 0.96
T.C.
18.20 17.39 16.87 16.87 16.60 18.52 17.52 16.99 16.99 16.72
85
S.C.
9.28 12.73 14.29 9.38 16.13 9.59 12.98 14.46 9.54 16.49
K.W.
1.07 1.06 1.05 1.05 1.03 1.09 1.07 1.06 1.06 1.05
T.C.
17.20 16.16 15.80 15.80 15.45 17.48 16.32 15.93 15.93 15.71
95
S.C.
9.00 12.32 12.88 7.96 15.16 9.34 12.41 13.33 8.42 15.57
K.W.
1.16 1.15 1.14 1.14 1.12 1.18 1.17 1.15 1.15 1.14
Multipliers for determining the performance with other indoor sections.
HIGH CFM
LOW CFM
Air Handler
Coil
T.C.
S.C.
KW
Air Handler
Coil
T.C.
S.C.
KW
N1VSB12
G2FD046S17
0.97
0.96
0.97
N1VSB12
G2FD046S17
0.94
0.99
0.96
N1VSC16
G2FD042S21
0.95
0.94
0.97
N1VSC16
G2FD042S21
0.93
0.97
0.96
Variable Speed Coil
Furnace
T.C.
S.C.
KW
Variable Speed Coil
Furnace
T.C.
S.C.
KW
P1XDB12V
G2FD046S17
0.94
0.94
0.98
P1XDB12V
G2FD046S17
0.85
0.84
0.90
P1XUB12V
G2FD046S17
0.93
0.93
0.97
P1XUB12V
G2FD046S17
0.85
0.84
0.90
P1XUB12V
G1UA048S17
0.93
0.93
0.97
P1XUB12V
G1UA048S17
0.85
0.84
0.90
P1XUB12V
G1FA048S17
0.93
0.93
0.97
P1XUB12V
G1FA048S17
0.85
0.84
0.90
P1DUB16V
G2FD046S17
0.94
0.94
0.97
P1DUB16V
G2FD046S17
0.84
0.83
0.88
P1DUB16V
G1UA048S17
0.94
0.94
0.97
P1DUB16V
G1UA048S17
0.84
0.83
0.88
P1DUB16V
G1FA048S17
0.94
0.94
0.97
P1DUB16V
G1FA048S17
0.84
0.83
0.88
P1DUC16V
G2FD042S21
0.93
0.93
0.99
P1DUC16V
G2FD042S21
0.84
0.84
0.90
P1DUC16V
G1UA048S21
0.96
0.96
1.00
P1DUC16V
G1UA048S21
0.85
0.84
0.88
P1DUC16V
G1FA048S21
0.96
0.96
1.00
P1DUC16V
G1FA048S21
0.85
0.86
0.88
P1DUC16V
G2FD048S21
0.97
0.96
0.99
P1DUC16V
G2FD048S21
0.88
0.88
0.90
NOTE: KW RATING IS FOR OUTDOOR AND INDOOR UNITS.
Unitary Products Group
13
036-21342-002 Rev. E (0505)
COOLING PERFORMANCE DATA
E4TS036S06A WITH N1VSC1606 / G2FD048S21 - HIGH CFM 2-CYLINDER OPERATION
ID CFM
CONDENSER
ENTERING AIR ID DB (°F)
TEMPERATURE ID WB (°F)
T.C.
75
S.C.
K.W.
T.C.
85
S.C.
K.W.
T.C.
95
S.C.
K.W.
T.C.
105
S.C.
K.W.
T.C.
115
S.C.
K.W.
T.C.
125
S.C.
K.W.
80
72
42.71
21.26
2.61
40.45
20.15
2.84
38.19
19.04
3.08
35.93
17.93
3.32
33.74
16.85
3.55
31.54
15.77
3.78
80
67
39.07
25.43
2.58
37.03
24.74
2.79
34.99
24.05
2.99
32.95
23.36
3.20
30.98
22.69
3.40
29.00
22.02
3.60
1000
80
62
35.00
31.63
2.47
33.34
30.32
2.67
31.68
29.02
2.87
30.02
27.71
3.07
28.42
26.44
3.26
26.81
25.17
3.45
75
62
35.00
26.34
2.47
33.34
25.03
2.67
31.68
23.72
2.87
30.02
22.42
3.07
28.42
21.15
3.26
26.81
19.88
3.45
80
57
33.88
32.81
2.46
32.20
31.29
2.65
30.51
29.77
2.85
28.83
28.26
3.05
27.19
26.79
3.24
25.56
25.31
3.42
80
72
43.34
21.75
2.73
40.99
20.83
2.96
38.64
19.90
3.20
36.29
18.97
3.43
34.01
18.07
3.66
31.73
17.18
3.88
80
67
40.24
27.35
2.68
38.12
26.61
2.89
36.00
25.61
3.10
33.88
25.12
3.31
31.83
24.40
3.51
29.77
23.68
3.71
1185
80
62
36.13
33.71
2.58
34.47
32.25
2.79
32.81
30.79
2.99
31.15
29.33
3.20
29.53
27.91
3.40
27.92
26.49
3.60
75
62
36.13
28.25
2.58
34.47
26.76
2.79
32.81
25.26
2.99
31.15
23.77
3.20
29.53
22.31
3.40
27.92
20.86
3.60
80
57
36.54
36.00
2.55
34.69
34.23
2.73
32.83
32.46
2.93
30.98
30.70
3.15
29.18
28.98
3.36
27.39
27.26
3.55
80
72
43.97
22.25
2.85
41.53
21.51
3.08
39.09
20.76
3.31
36.65
20.02
3.54
34.29
19.30
3.77
31.92
18.58
3.99
80
67
41.41
29.27
2.79
39.21
28.48
3.00
37.01
27.68
3.21
34.81
26.89
3.42
32.67
26.12
3.62
30.54
25.34
3.82
1350
80
62
37.26
35.79
2.69
35.60
34.18
2.90
33.93
32.56
3.12
32.27
30.94
3.33
30.65
29.38
3.54
29.04
27.81
3.75
75
62
37.26
30.17
2.69
35.60
28.48
2.90
33.93
26.80
3.12
32.27
25.11
3.33
30.65
23.48
3.54
29.04
21.84
3.75
80
57
39.19
39.19
2.64
37.17
37.17
2.82
35.15
35.15
3.01
33.13
33.13
3.24
31.18
31.18
3.47
29.22
29.22
3.68
Multipliers for determining the performance with other indoor sections.
HIGH CFM
Air Handler
Coil
T.C.
S.C.
KW
N1VSD20
G2FD048S24
1.01
1.02
1.00
Variable Speed Coil
Furnace
T.C.
S.C.
KW
P1DUC20V
G1UA048S21
0.99
1.01
1.03
P1DUC20V
G1FA048S21
0.99
1.01
1.03
P1DUC20V
G2FD048S21
1.00
1.02
1.03
1.05
Variable Speed Coil
Furnace
T.C.
S.C.
KW
P1XDB12V
G2FD046S17
0.99
1.01
1.06
P1DUC20V
G1UA060S21
1.03
1.04
P1XUB12V
G2FD046S17
0.98
1.00
1.04
P1DUC20V
G1FA060S21
1.03
1.04
1.05
P1XUB12V
G1UA048S17
0.98
1.00
1.04
P1XUC20V
G1UA048S21
0.99
1.00
1.04
P1XUB12V
G1FA048S17
0.98
1.00
1.04
P1XUC20V
G1FA048S21
0.99
1.00
1.04
P1DUB16V
G2FD046S17
0.99
1.00
1.04
P1XUC20V
G2FD048S21
0.99
1.01
1.03
P1DUB16V
G1UA048S17
0.99
1.00
1.04
P1XUC20V
G1UA060S21
1.02
1.03
1.05
P1DUB16V
G1FA048S17
0.99
1.00
1.04
P1XUC20V
G1FA060S21
1.02
1.03
1.05
P1DUC16V
G1UA048S21
0.99
1.01
1.04
P1XDD20V
G2FD048S24
1.00
1.07
1.03
P1DUC16V
G1FA048S21
0.99
1.01
1.04
P1XUD20V
G1UA048S24
1.01
1.06
1.04
P1DUC16V
G2FD048S21
1.00
1.02
1.05
P1XUD20V
G1FA048S24
1.01
1.06
1.04
P1DUC16V
G1UA060S21
1.03
1.04
1.06
P1XUD20V
G2FD048S24
1.01
1.07
1.03
P1DUC16V
G1FA060S21
1.03
1.04
1.06
P1XUD20V
G1UA060S24
1.04
1.09
1.04
P1XUD20V
G1FA060S24
1.04
1.09
1.04
NOTE: KW RATING IS FOR OUTDOOR AND INDOOR UNITS.
14
Unitary Products Group
036-21342-002 Rev. E (0505)
COOLING PERFORMANCE DATA
E4TS036S06A WITH N1VSC1606 / G2FD048S21 - LOW CFM 1-CYLINDER OPERATION
ID CFM
CONDENSER
ENTERING AIR ID DB (°F)
TEMPERATURE ID WB (°F)
T.C.
75
S.C.
K.W.
T.C.
85
S.C.
K.W.
T.C.
95
S.C.
K.W.
80
72
25.53
12.14
1.35
24.11
11.53
1.48
22.70
10.93
1.62
80
67
22.96
15.13
1.35
21.94
14.70
1.47
20.91
14.27
1.58
680
80
62
21.67
18.09
1.33
20.57
17.83
1.45
19.46
17.56
1.56
75
62
21.67
14.65
1.33
20.57
14.38
1.45
19.46
14.12
1.56
80
57
19.33
19.09
1.33
18.91
18.63
1.44
18.49
18.17
1.56
80
72
25.89
12.67
1.37
24.68
12.20
1.50
23.47
11.73
1.64
80
67
23.72
16.04
1.37
22.56
15.80
1.49
21.40
15.40
1.61
770
80
62
22.21
19.20
1.36
21.14
18.30
1.47
20.08
17.40
1.59
75
62
22.21
15.76
1.36
21.14
14.82
1.47
20.08
13.89
1.59
80
57
20.25
20.13
1.34
19.62
19.48
1.46
19.00
18.84
1.58
80
72
26.24
13.20
1.39
25.25
12.87
1.53
24.25
12.54
1.66
80
67
24.48
16.95
1.38
23.19
16.91
1.51
21.89
16.87
1.63
860
80
62
22.74
20.32
1.38
21.72
18.78
1.50
20.70
17.24
1.61
75
62
22.74
16.87
1.38
21.72
15.26
1.50
20.70
13.66
1.61
80
57
21.17
21.17
1.35
20.34
20.34
1.47
19.51
19.51
1.60
Multipliers for determining the performance with other indoor sections.
LOW CFM
Air Handler
Coil
T.C.
S.C.
KW
N1VSD20
G2FD048S24
1.01
1.01
0.99
Variable Speed Coil
Furnace
T.C.
S.C.
KW
P1DUC20V
G1UA048S21
0.94
0.99
1.00
P1DUC20V
G1FA048S21
0.94
0.99
1.00
P1DUC20V
G2FD048S21
0.95
1.00
0.99
G1UA060S21
0.98
1.03
1.00
Variable Speed Coil
Furnace
T.C.
S.C.
KW
P1XDB12V
0.93
0.99
1.00
P1DUC20V
G2FD046S17
P1XUB12V
G2FD046S17
0.93
0.97
0.98
P1DUC20V
G1FA060S21
0.98
1.03
1.00
P1XUB12V
G1UA048S17
0.93
0.97
0.98
P1XUC20V
G1UA048S21
0.93
0.97
0.99
P1XUB12V
G1FA048S17
0.93
0.97
0.98
P1XUC20V
G1FA048S21
0.93
0.97
0.99
P1DUB16V
G2FD046S17
0.93
0.97
0.99
P1XUC20V
G2FD048S21
0.94
0.99
0.99
P1DUB16V
G1UA048S17
0.93
0.97
0.99
P1XUC20V
G1UA060S21
0.97
1.01
0.99
P1DUB16V
G1FA048S17
0.93
0.97
0.99
P1XUC20V
G1FA060S21
0.97
1.01
0.99
P1DUC16V
G1UA048S21
0.94
0.99
1.00
P1XDD20V
G2FD048S24
0.95
1.05
0.98
P1DUC16V
G1FA048S21
0.94
0.99
1.00
P1XUD20V
G1UA048S24
0.96
1.04
1.00
P1DUC16V
G2FD048S21
0.95
1.00
1.01
P1XUD20V
G1FA048S24
0.96
1.04
1.00
P1DUC16V
G1UA060S21
0.98
1.03
1.00
P1XUD20V
G2FD048S24
0.97
1.05
0.99
P1DUC16V
G1FA060S21
0.98
1.03
1.00
P1XUD20V
G1UA060S24
1.00
1.08
1.00
P1XUD20V
G1FA060S24
1.00
1.08
1.00
NOTE: KW RATING IS FOR OUTDOOR AND INDOOR UNITS.
Unitary Products Group
15
036-21342-002 Rev. E (0505)
COOLING PERFORMANCE DATA
E4TS048S06A WITH N1VSD2006 / G2FD060S24 - HIGH CFM 2-CYLINDER OPERATION
ID CFM
CONDENSER
ENTERING AIR ID DB (°F)
TEMPERATURE ID WB (°F)
T.C.
75
S.C.
K.W.
T.C.
85
S.C.
K.W.
T.C.
95
S.C.
K.W.
T.C.
105
S.C.
K.W.
T.C.
115
S.C.
K.W.
T.C.
125
S.C.
K.W.
80
72
56.47
28.32
3.61
53.54
27.19
3.91
50.60
26.05
4.21
47.67
24.92
4.50
44.83
23.83
4.79
41.98
22.73
5.08
80
67
53.15
36.17
3.49
50.52
35.23
3.77
47.89
34.28
4.04
45.26
33.33
4.32
42.71
32.41
4.59
40.16
31.50
4.86
1420
80
62
46.83
42.10
3.34
44.60
41.03
3.59
42.38
39.96
3.84
40.15
38.89
4.08
37.99
37.85
4.33
35.83
36.81
4.57
75
62
46.83
34.23
3.34
44.60
33.16
3.59
42.38
32.09
3.84
40.15
31.02
4.08
37.99
29.98
4.33
35.83
28.94
4.57
80
57
39.34
38.85
3.30
38.36
37.86
3.54
37.29
36.87
3.81
35.74
35.52
4.04
34.19
34.03
4.26
32.61
32.58
4.48
80
72
56.73
29.16
3.79
53.57
27.99
4.09
50.42
26.81
4.39
47.26
25.63
4.69
44.20
24.49
4.98
41.14
23.34
5.27
80
67
53.18
37.77
3.66
50.59
36.86
3.94
48.00
35.60
4.21
45.41
35.04
4.49
42.90
34.16
4.76
40.39
33.28
5.03
1600
80
62
47.38
43.94
3.48
45.30
42.50
3.74
43.22
41.06
3.99
41.14
39.63
4.25
39.13
38.23
4.50
37.11
36.84
4.75
75
62
47.38
36.08
3.48
45.30
34.61
3.74
43.22
33.14
3.99
41.14
31.66
4.25
39.13
30.23
4.50
37.11
28.80
4.75
80
57
40.76
40.51
3.36
39.65
39.40
3.60
38.48
38.27
3.87
37.04
36.93
4.16
35.62
35.53
4.38
34.54
34.52
4.64
80
72
56.99
30.01
3.97
53.61
28.79
4.28
50.24
27.56
4.58
46.86
26.34
4.88
43.58
25.15
5.18
40.30
23.96
5.47
80
67
53.21
39.37
3.82
50.66
38.50
4.10
48.11
37.63
4.38
45.56
36.76
4.66
43.09
35.91
4.93
40.62
35.06
5.20
1750
80
62
47.93
45.77
3.62
46.00
43.97
3.89
44.07
42.17
4.15
42.13
40.36
4.42
40.26
38.61
4.68
38.38
36.86
4.93
75
62
47.93
37.93
3.62
46.00
36.06
3.89
44.07
34.18
4.15
42.13
32.30
4.42
40.26
30.48
4.68
38.38
28.66
4.93
80
57
42.18
42.18
3.41
40.94
40.94
3.66
39.66
39.66
3.94
38.34
38.34
4.29
37.04
37.04
4.49
36.46
36.46
4.80
80
72
32.53
16.84
1.66
30.30
16.20
1.84
28.06
15.56
2.01
80
67
30.07
22.62
1.64
28.44
22.33
1.81
26.80
22.03
1.97
1140
80
62
27.86
24.57
1.62
26.54
23.99
1.77
25.22
23.42
1.91
75
62
27.86
19.60
1.62
26.54
19.00
1.77
25.22
18.40
1.91
80
57
25.63
25.63
1.60
26.43
26.43
1.74
23.20
23.20
1.87
E4TS048S06A WITH N1VSD2006 / G2FD060S24 - LOW CFM 1-CYLINDER OPERATION
ID CFM
CONDENSER
ENTERING AIR ID DB (°F)
TEMPERATURE ID WB (°F)
T.C.
75
S.C.
K.W.
T.C.
85
S.C.
K.W.
T.C.
95
S.C.
K.W.
80
72
28.53
13.88
1.67
28.30
14.72
1.84
28.06
15.56
2.01
80
67
27.17
20.03
1.62
26.99
21.03
1.79
26.80
22.03
1.97
850
80
62
25.56
22.49
1.57
25.39
23.45
1.74
25.22
24.42
1.91
75
62
25.56
18.01
1.57
25.39
18.97
1.74
25.22
19.93
1.91
80
57
24.29
23.48
1.51
24.12
23.45
1.69
25.01
24.67
1.85
80
72
30.53
15.36
1.67
29.30
15.46
1.84
28.06
15.56
2.01
80
67
28.62
21.33
1.63
27.71
21.68
1.80
26.80
21.80
1.97
1040
80
62
26.71
23.53
1.60
25.97
23.72
1.76
25.22
23.92
1.91
75
62
26.71
18.80
1.60
25.97
18.98
1.76
25.22
19.17
1.91
80
57
24.96
24.56
1.56
25.28
24.94
1.71
24.11
23.94
1.86
Multipliers for determining the performance with other indoor sections.
HIGH CFM
LOW CFM
Air Handler
Coil
T.C.
S.C.
KW
Air Handler
Coil
T.C.
S.C.
KW
N1VSD20
G1FD061S24
G1FD061S24
1.02
1.02
1.00
N1VSD20
1.02
1.02
1.01
F(2,3)FV060
1.00
1.00
1.00
F(2,3)FV060
1.00
1.00
1.00
Variable Speed
Coil
Furnace
T.C.
S.C.
KW
Variable Speed
Coil
Furnace
T.C.
S.C.
KW
0.96
P1DUC16V
G1UA060S21
0.98
0.95
1.03
P1DUC16V
G1UA060S21
0.89
0.81
P1DUC16V
G1FA060S21
0.98
0.95
1.03
P1DUC16V
G1FA060S21
0.89
0.81
0.96
P1DUC20V
G1UA060S21
0.99
0.96
1.04
P1DUC20V
G1UA060S21
0.90
0.83
0.97
P1DUC20V
G1FA060S21
0.99
0.96
1.04
P1DUC20V
G1FA060S21
0.90
0.83
0.97
P1XUC20V
G1UA060S21
0.98
0.95
1.03
P1XUC20V
G1UA060S21
0.88
0.80
0.95
P1XUC20V
G1FA060S21
0.98
0.95
1.03
P1XUC20V
G1FA060S21
0.88
0.80
0.95
P1XDD20V
G2FD060S24
0.99
0.96
1.03
P1XDD20V
G2FD060S24
0.91
0.84
0.99
P1XDD20V
G2FD061H24
1.01
0.98
1.03
P1XDD20V
G2FD061H24
0.93
0.86
0.99
P1XUD20V
G1UA060S24
1.00
0.97
1.04
P1XUD20V
G1UA060S24
0.93
0.86
0.99
P1XUD20V
G1FA060S24
1.00
0.97
1.04
P1XUD20V
G1FA060S24
0.93
0.86
0.99
P1XUD20V
G2FD060S24
1.00
0.97
1.04
P1XUD20V
G2FD060S24
0.93
0.86
0.99
P1XUD20V
G2FD061H24
1.02
0.99
1.03
P1XUD20V
G2FD061H24
0.94
0.86
0.99
NOTE: KW RATING IS FOR OUTDOOR AND INDOOR UNITS.
16
Unitary Products Group
036-21342-002 Rev. E (0505)
COOLING PERFORMANCE DATA
E4TS060S06A WITH N1VSD2006 / G2FD061S24 - HIGH CFM 2-CYLINDER OPERATION
ID CFM
CONDENSER
ENTERING AIR ID DB (°F)
TEMPERATURE ID WB (°F)
T.C.
75
S.C.
K.W.
T.C.
85
S.C.
K.W.
T.C.
95
S.C.
K.W.
T.C.
105
S.C.
K.W.
T.C.
115
S.C.
K.W.
T.C.
125
S.C.
K.W.
80
72
65.80
32.90
4.53
62.52
31.56
4.95
59.25
30.22
5.30
55.97
28.89
5.66
52.79
27.59
6.06
49.61
26.29
6.43
80
67
61.90
42.32
4.43
58.95
41.12
4.77
56.00
39.93
5.10
53.05
38.73
5.44
50.19
37.57
5.76
47.33
36.41
6.09
1540
80
62
55.01
49.80
4.30
52.76
48.61
4.58
50.51
47.42
4.85
48.27
46.23
5.13
46.09
45.08
5.40
43.91
43.93
5.66
75
62
55.01
40.94
4.30
52.76
39.75
4.58
50.51
38.57
4.85
48.27
37.38
5.13
46.09
36.22
5.40
43.91
35.07
5.66
80
57
53.57
51.43
4.20
51.36
49.31
4.49
49.15
47.19
4.78
46.94
44.68
5.07
44.80
42.43
5.35
42.66
40.19
5.64
80
72
65.60
33.42
4.76
62.48
32.21
5.15
59.36
31.01
5.51
56.25
29.80
5.87
53.22
28.63
6.25
50.19
27.46
6.62
80
67
63.40
44.11
4.66
60.20
43.00
4.99
57.00
41.50
5.38
53.80
40.79
5.64
50.70
39.72
5.96
47.59
38.64
6.27
1860
80
62
57.21
51.70
4.50
54.76
50.40
4.78
52.31
49.09
5.07
49.85
47.79
5.35
47.47
46.52
5.63
45.10
45.25
5.91
75
62
57.21
42.35
4.50
54.76
41.02
4.78
52.31
39.69
5.07
49.85
38.35
5.35
47.47
37.06
5.63
45.10
35.77
5.91
80
57
56.10
55.02
4.43
53.68
52.66
4.72
51.27
50.29
5.00
48.86
47.73
5.30
46.52
45.33
5.58
44.17
42.94
5.86
80
72
65.40
33.94
4.99
62.44
32.86
5.35
59.48
31.79
5.72
56.52
30.71
6.09
53.64
29.67
6.44
50.77
28.63
6.80
80
67
64.90
45.90
4.89
61.45
44.88
5.21
58.00
43.87
5.52
54.55
42.85
5.84
51.21
41.86
6.15
47.86
40.87
6.46
2075
80
62
59.41
53.60
4.69
56.75
52.18
4.99
54.10
50.76
5.28
51.44
49.34
5.58
48.86
47.96
5.86
46.28
46.58
6.15
75
62
59.41
43.76
4.69
56.75
42.28
4.99
54.10
40.81
5.28
51.44
39.33
5.58
48.86
37.90
5.86
46.28
36.46
6.15
80
57
58.62
58.62
4.65
56.00
56.00
4.94
53.39
53.39
5.22
50.77
50.77
5.53
48.23
48.23
5.81
45.69
45.69
6.08
80
72
36.12
19.97
1.82
34.76
19.47
2.05
33.39
18.96
2.28
80
67
33.70
25.56
1.81
31.92
25.50
2.03
30.13
25.44
2.25
1350
80
62
31.31
30.93
1.81
29.90
28.59
2.02
28.49
26.25
2.23
75
62
31.31
22.39
1.81
29.90
19.98
2.02
28.49
17.56
2.23
80
57
29.15
29.15
1.77
28.00
28.00
1.98
26.85
26.85
2.19
E4TS060S06A WITH N1VSD2006 / G2FD061S24 - LOW CFM 1-CYLINDER OPERATION
ID CFM
CONDENSER
ENTERING AIR ID DB (°F)
TEMPERATURE ID WB (°F)
T.C.
75
S.C.
K.W.
T.C.
85
S.C.
K.W.
T.C.
95
S.C.
K.W.
80
72
32.55
17.01
1.63
30.74
16.16
1.85
28.93
15.31
2.07
80
67
29.26
21.12
1.64
27.96
20.52
1.83
26.66
19.92
2.03
1000
80
62
27.63
25.18
1.61
26.21
24.82
1.81
24.80
24.45
2.00
75
62
27.63
18.13
1.61
26.21
17.77
1.81
24.80
17.40
2.00
80
57
24.63
23.65
1.61
24.10
23.14
1.79
23.57
22.63
1.98
80
72
34.33
18.49
1.73
32.75
17.81
1.95
31.16
17.14
2.18
80
67
31.48
23.34
1.72
29.94
23.01
1.93
29.00
24.00
2.16
1200
80
62
29.47
28.06
1.71
28.06
26.70
1.91
26.65
25.35
2.12
75
62
29.47
20.26
1.71
28.06
18.87
1.91
26.65
17.48
2.12
80
57
26.89
26.40
1.69
26.05
25.57
1.89
25.21
24.74
2.09
Multipliers for determining the performance with other indoor sections.
HIGH CFM
LOW CFM
Air Handler
Coil
T.C.
S.C.
KW
Air Handler
Coil
T.C.
S.C.
KW
N1VSD20
G1FD060S24
0.97
0.98
0.99
N1VSD20
G1FD060S24
0.96
0.98
0.98
F(2,3)FV060
0.97
0.98
0.99
F(2,3)FV060
0.96
0.98
0.98
Variable Speed
Coil
Furnace
T.C.
S.C.
KW
Variable Speed
Coil
Furnace
T.C.
S.C.
KW
P1XDD20V
G2FD060S24
0.96
0.95
1.02
P1XDD20V
G2FD060S24
0.93
0.85
0.99
P1XDD20V
G2FD061H24
0.98
0.96
1.02
P1XDD20V
G2FD061H24
0.97
0.87
1.01
P1XUD20V
G1UA060S24
0.97
0.96
1.01
P1XUD20V
G1UA060S24
0.93
0.85
1.00
P1XUD20V
G1FA060S24
0.97
0.96
1.01
P1XUD20V
G1FA060S24
0.93
0.85
1.00
P1XUD20V
G2FD060S24
0.97
0.96
1.01
P1XUD20V
G2FD060S24
0.93
0.85
1.00
P1XUD20V
G2FD061H24
0.99
0.98
1.01
P1XUD20V
G2FD061H24
0.97
0.87
1.01
NOTE: KW RATING IS FOR OUTDOOR AND INDOOR UNITS.
Unitary Products Group
17
036-21342-002 Rev. E (0505)
HEATING PERFORMANCE DATA
E4TS030S06A WITH N1VSC1606 / G2FD048S21 - HIGH CFM 2-CYLINDER OPERATION
ID CFM
OD DB
980
ID DB (°F)
60
70
80
60
70
80
60
70
80
60
70
80
60
70
80
60
70
80
60
47
35
17
7
-3
MBTUH1,2
35.86
33.48
31.09
28.88
26.78
24.68
22.40
20.57
18.73
16.95
15.20
13.46
12.23
11.24
10.24
7.92
7.28
6.63
1065
KW
2.17
2.30
2.43
2.04
2.14
2.24
1.90
1.98
2.05
1.71
1.77
1.83
1.50
1.57
1.64
1.37
1.43
1.49
1210
MBTUH1,2
36.10
33.93
31.77
29.01
27.00
24.99
22.79
20.94
19.10
17.09
15.40
13.71
12.34
11.39
10.43
7.99
7.37
6.75
KW
2.19
2.31
2.44
2.07
2.17
2.26
1.92
2.00
2.08
1.74
1.84
1.94
1.52
1.60
1.68
1.39
1.46
1.53
MBTUH1,2
36.34
34.39
32.44
29.14
27.22
25.29
23.17
21.31
19.46
17.22
15.60
13.97
12.45
11.53
10.62
8.06
7.47
6.87
KW
2.20
2.32
2.45
2.09
2.19
2.29
1.94
2.02
2.10
1.78
1.83
1.88
1.54
1.61
1.68
1.41
1.47
1.53
E4TS030S06A WITH N1VSC1606 / G2FD048S21 - LOW CFM 1-CYLINDER OPERATION
ID CFM
OD DB
650
720
770
ID DB (°F)
MBTUH1,2
KW
MBTUH1,2
KW
MBTUH1,2
KW
60
70
80
60
70
80
60
70
80
20.36
18.50
16.64
16.02
14.90
13.77
12.60
12.00
11.40
1.08
1.16
1.24
1.05
1.12
1.19
1.02
1.08
1.13
20.52
18.66
16.79
16.15
15.00
13.85
12.71
12.07
11.42
1.09
1.17
1.25
1.06
1.13
1.20
1.04
1.10
1.15
20.67
18.81
16.95
16.28
15.10
13.93
12.82
12.13
11.45
1.09
1.17
1.25
1.08
1.14
1.20
1.07
1.12
1.16
60
47
35
For notes see Page 11.
Multipliers for determining the performance with other indoor sections.
2-CYLINDER OPERATION
1-CYLINDER OPERATION
HIGH CFM
LOW CFM
Air Handler
Coil
N1VSB12
G2FD046S17
0.98
0.99
0.91
N1VSC16
G2FD042S21
0.96
0.98
0.90
Variable Speed
Coil
Furnace
LOW CFM
Air Handler
Coil
0.96
N1VSB12
G2FD046S17
0.89
0.91
0.95
N1VSC16
G2FD042S21
0.88
0.90
MBTUH KW MBTUH KW
MBTUH KW MBTUH KW
Variable Speed
Coil
Furnace
MBTUH KW
MBTUH KW
P1XDB12V
G2FD046S17
0.97
1.00
0.89
0.94
P1XDB12V
G2FD046S17
0.85
0.93
P1XUB12V
G2FD046S17
0.96
1.00
0.88
0.95
P1XUB12V
G2FD046S17
0.85
0.93
P1XUB12V
G1UA048S17
0.96
1.00
0.88
0.95
P1XUB12V
G1UA048S17
0.85
0.93
P1XUB12V
G1FA048S17
0.96
1.00
0.88
0.95
P1XUB12V
G1FA048S17
0.85
0.93
P1DUB16V
G2FD046S17
0.98
1.00
0.90
0.95
P1DUB16V
G2FD046S17
0.83
0.91
P1DUB16V
G1UA048S17
0.98
1.00
0.90
0.95
P1DUB16V
G1UA048S17
0.83
0.91
P1DUB16V
G1FA048S17
0.98
1.00
0.90
0.95
P1DUB16V
G1FA048S17
0.83
0.91
P1DUC16V
G2FD042S21
1.00
1.00
0.92
0.95
P1DUC16V
G2FD042S21
0.87
0.91
P1DUC16V
G1UA048S21
1.01
1.01
0.93
0.96
P1DUC16V
G1UA048S21
0.88
0.92
P1DUC16V
GFA048S21
1.01
1.01
0.93
0.96
P1DUC16V
GFA048S21
0.88
0.92
P1DUC16V
G2FD048S21
1.02
1.02
0.94
0.97
P1DUC16V
G2FD048S21
0.89
0.92
NOTE: KW RATING IS FOR OUTDOOR AND INDOOR UNITS.
18
Unitary Products Group
036-21342-002 Rev. E (0505)
HEATING PERFORMANCE DATA
E4TS036S06A WITH N1VSC1606 / G2FD048S21 - HIGH CFM 2-CYLINDER OPERATION
ID CFM
OD DB
1000
ID DB (°F)
60
70
80
60
70
80
60
70
80
60
70
80
60
70
80
60
70
80
60
47
35
17
7
-3
MBTUH1,2
42.57
40.33
38.08
38.00
35.19
32.38
30.23
27.59
24.96
22.29
20.61
18.93
17.34
16.08
14.83
12.18
11.30
10.42
1185
KW
2.80
2.98
3.17
2.63
2.77
2.91
2.37
2.48
2.59
2.14
2.22
2.29
1.92
2.02
2.12
1.76
1.85
1.94
1350
MBTUH1,2
43.13
40.99
38.85
38.09
35.60
33.11
30.03
27.79
25.56
22.47
21.20
19.93
17.41
16.34
15.27
12.23
11.48
10.73
KW
2.81
2.99
3.17
2.64
2.79
2.94
2.40
2.52
2.64
2.20
2.27
2.34
1.95
2.05
2.14
1.79
1.88
1.97
MBTUH1,2
43.69
41.65
39.61
38.18
36.01
33.83
29.82
27.99
26.16
22.64
21.79
20.94
17.48
16.60
15.71
12.28
11.66
11.04
KW
2.82
3.00
3.18
2.66
2.81
2.96
2.44
2.57
2.69
2.25
2.32
2.39
1.97
2.07
2.17
1.81
1.90
1.99
For notes see Page 11.
Multipliers for determining the performance with other indoor sections.
2-CYLINDER OPERATION
Air Handler
Coil
N1VSB12
G2FD046S17
Variable Speed
Coil
Furnace
HIGH CFM
LOW CFM
MBTUH KW MBTUH KW
0.98
1.04
0.89
0.94
MBTUH KW MBTUH KW
P1XDB12V
G2FD046S17
0.97
1.03
0.87
0.96
P1XUB12V
G2FD046S17
0.97
1.02
0.87
0.95
P1XUB12V
G1UA048S17
0.98
1.03
0.88
0.95
P1XUB12V
G1FA048S17
0.98
1.03
0.88
0.95
P1DUB16V
G2FD046S17
0.97
1.02
0.87
0.95
P1DUB16V
G1UA048S17
0.98
1.03
0.88
0.95
P1DUB16V
G1FA048S17
0.98
1.03
0.88
0.95
P1DUC16V
G1UA048S21
0.99
1.02
0.89
0.95
P1DUC16V
G1FA048S21
0.99
1.02
0.89
0.95
P1DUC16V
G2FD048S21
1.00
1.02
0.90
0.95
P1DUC16V
G1UA060S21
1.01
1.01
0.91
0.94
P1DUC16V
G1FA060S21
1.01
1.01
0.91
0.94
Variable Speed
Coil
Furnace
HIGH CFM
LOW CFM
MBTUH KW MBTUH KW
P1DUC20V
G1UA048S21
0.99
1.03
0.89
P1DUC20V
G1FA048S21
0.99
1.03
0.89
0.95
P1DUC20V
G2FD048S21
1.00
1.02
0.90
0.95
P1DUC20V
G1UA060S21
1.02
1.02
0.92
0.95
P1DUC20V
G1FA060S21
1.02
1.02
0.92
0.95
P1XUC20V
G1UA048S21
0.99
1.03
0.89
0.96
P1XUC20V
G1FA048S21
0.99
1.03
0.89
0.96
P1XUC20V
G2FD048S21
1.00
1.03
0.90
0.95
P1XUC20V
G1UA060S21
1.02
1.03
0.92
0.96
P1XUC20V
G1FA060S21
1.02
1.03
0.92
0.96
P1XDD20V
G2FD048S24
1.00
0.98
0.90
0.91
P1XUD20V
G1UA048S24
1.02
1.00
0.92
0.93
P1XUD20V
G1FA048S24
1.02
1.00
0.92
0.93
P1XUD20V
G2FD048S24
1.02
1.00
0.92
0.93
P1XUD20V
G1UA060S24
1.04
1.00
0.94
0.93
P1XUD20V
G1FA060S24
1.04
1.00
0.94
0.93
NOTE: KW RATING IS FOR OUTDOOR AND INDOOR UNITS.
Unitary Products Group
0.95
19
036-21342-002 Rev. E (0505)
HEATING PERFORMANCE DATA
E4TS036S06A WITH N1VSC1606 / G2FD048S21 - LOW CFM 1-CYLINDER OPERATION
ID CFM
OD DB
670
ID DB (°F)
60
70
80
60
70
80
60
70
80
60
47
35
770
MBTUH1,2
24.27
22.72
21.16
21.43
19.73
18.03
18.92
17.14
15.35
KW
1.49
1.59
1.70
1.42
1.51
1.59
1.36
1.42
1.49
860
MBTUH1,2
24.88
23.42
21.96
21.73
20.00
18.42
18.99
17.22
15.45
MBTUH1,2
25.48
24.13
22.77
22.04
20.42
18.81
19.06
17.30
15.54
KW
1.50
1.61
1.71
1.43
1.52
1.61
1.36
1.44
1.51
KW
1.51
1.62
1.73
1.44
1.53
1.62
1.37
1.45
1.52
For notes see Page 11.
Multipliers for determining the performance with other indoor sections.
1-CYLINDER OPERATION
Air Handler
Coil
N1VSB12
G2FD046S17
Variable Speed
Coil
Furnace
LOW CFM
LOW CFM
MBTUH
KW
Variable Speed
Coil
Furnace
MBTUH
KW
0.98
1.00
P1DUC20V
G1UA048S21
0.85
0.93
P1DUC20V
G1FA048S21
0.85
0.93
P1DUC20V
G2FD048S21
0.86
0.93
P1DUC20V
G1UA060S21
0.88
0.94
MBTUH
KW
P1XDB12V
G2FD046S17
0.87
0.94
P1XUB12V
G2FD046S17
0.86
0.94
P1XUB12V
G1UA048S17
0.87
0.94
P1XUB12V
G1FA048S17
0.87
0.94
P1DUB16V
G2FD046S17
0.85
0.93
P1DUB16V
G1UA048S17
0.86
0.93
P1DUB16V
G1FA048S17
0.86
0.93
P1DUC16V
G1UA048S21
0.85
0.93
P1DUC16V
G1FA048S21
0.85
0.93
P1DUC16V
G2FD048S21
0.86
0.93
P1DUC16V
G1UA060S21
0.88
0.94
P1DUC16V
G1FA060S21
0.88
0.94
P1DUC20V
G1FA060S21
0.88
0.94
P1XUC20V
G1UA048S21
0.83
0.92
P1XUC20V
G1FA048S21
0.83
0.92
P1XUC20V
G2FD048S21
0.84
0.92
P1XUC20V
G1UA060S21
0.86
0.93
P1XUC20V
G1FA060S21
0.86
0.93
P1XDD20V
G2FD048S24
0.90
0.98
P1XUD20V
G1UA048S24
0.90
0.99
P1XUD20V
G1FA048S24
0.90
0.99
P1XUD20V
G2FD048S24
0.91
0.99
P1XUD20V
G1UA060S24
0.94
1.00
P1XUD20V
G1FA060S24
0.94
1.00
NOTE: KW RATING IS FOR OUTDOOR AND INDOOR UNITS.
20
Unitary Products Group
036-21342-002 Rev. E (0505)
HEATING PERFORMANCE DATA
E4TS048S06A WITH N1VSD2006 / G2FD060S24 - HIGH CFM 2-CYLINDER OPERATION
ID CFM
OD DB
1420
ID DB (°F)
60
70
80
60
70
80
60
70
80
60
70
80
60
70
80
60
70
80
60
47
35
17
7
-3
MBTUH1,2
58.57
55.72
52.87
48.43
46.01
43.60
39.06
36.62
34.17
28.62
26.00
23.38
21.24
19.89
18.55
14.73
13.79
12.86
1600
KW
4.00
4.22
4.44
3.61
3.79
3.96
3.24
3.38
3.52
2.97
3.05
3.13
2.68
2.79
2.91
2.48
2.58
2.69
1750
MBTUH1,2
59.37
56.47
53.56
49.54
47.00
44.46
39.49
37.06
34.63
28.81
26.40
23.99
21.53
20.21
18.88
14.93
14.01
13.09
KW
4.01
4.24
4.47
3.66
3.85
4.03
3.31
3.46
3.62
3.06
3.16
3.26
2.72
2.85
2.98
2.53
2.64
2.76
MBTUH1,2
60.17
57.21
54.26
50.65
47.99
45.32
39.92
37.51
35.09
29.00
26.80
24.60
21.82
20.52
19.22
15.13
14.22
13.32
KW
4.02
4.26
4.50
3.72
3.91
4.10
3.37
3.55
3.72
3.15
3.27
3.39
2.77
2.91
3.05
2.57
2.70
2.82
E4TS048S06A WITH N1VSD2006 / G2FD060S24 - LOW CFM 1-CYLINDER OPERATION
ID CFM
OD DB
850
1040
1140
ID DB (°F)
MBTUH1,2
KW
MBTUH1,2
KW
MBTUH1,2
KW
60
70
80
60
70
80
60
70
80
29.44
27.16
24.88
25.88
23.31
20.73
22.75
20.01
17.27
1.89
2.00
2.12
1.80
1.90
1.99
1.72
1.80
1.87
30.37
28.00
25.62
26.28
23.80
21.32
22.75
20.24
17.73
1.88
2.00
2.12
1.81
1.91
2.00
1.74
1.82
1.89
31.31
28.83
26.36
26.68
24.29
21.90
22.75
20.47
18.20
1.87
2.00
2.13
1.81
1.91
2.01
1.76
1.83
1.90
60
47
35
For notes see Page 11.
Multipliers for determining the performance with other indoor sections.
2-CYLINDER OPERATION
Air Handler
Coil
N1VSD20
G1FD061S24
F(2,3)FV060
Variable Speed
Coil
Furnace
1-CYLINDER OPERATION
HIGH CFM
LOW CFM
MBTUH KW MBTUH KW
Air Handler
Coil
G1FD061S24
1.02
1.00
0.95
0.95
N1VSD20
1.00
1.00
0.93
0.95
F(2,3)FV060
MBTUH KW MBTUH KW
Variable Speed
Coil
Furnace
LOW CFM
MBTUH
KW
1.02
1.00
1.00
1.00
MBTUH
KW
0.99
P1DUC16V
G1UA060S21
1.00
1.01
0.93
0.96
P1DUC16V
G1UA060S21
0.87
P1DUC16V
G1FA060S21
1.00
1.01
0.93
0.96
P1DUC16V
G1FA060S21
0.87
0.99
P1DUC20V
G1UA060S21
1.00
0.99
0.93
0.94
P1DUC20V
G1UA060S21
0.90
0.99
P1DUC20V
G1FA060S21
1.00
0.99
0.93
0.94
P1DUC20V
G1FA060S21
0.90
0.99
P1XUC20V
G1UA060S21
0.99
1.00
0.91
0.95
P1XUC20V
G1UA060S21
0.85
0.97
P1XUC20V
G1FA060S21
0.99
1.00
0.91
0.95
P1XUC20V
G1FA060S21
0.85
0.97
P1XDD20V
G2FD060S24
0.99
1.01
0.91
0.95
P1XDD20V
G2FD060S24
0.90
1.00
P1XDD20V
G2FD061H24
1.01
1.01
0.94
0.95
P1XDD20V
G2FD061H24
0.92
1.00
P1XUD20V
G1UA060S24
1.01
1.02
0.94
0.97
P1XUD20V
G1UA060S24
0.93
1.02
P1XUD20V
G1FA060S24
1.01
1.02
0.94
0.97
P1XUD20V
G1FA060S24
0.93
1.02
P1XUD20V
G2FD060S24
1.01
1.02
0.94
0.97
P1XUD20V
G2FD060S24
0.93
1.02
P1XUD20V
G2FD061H24
1.03
1.02
0.96
0.97
P1XUD20V
G2FD061H24
0.95
1.02
NOTE: KW RATING IS FOR OUTDOOR AND INDOOR UNITS.
Unitary Products Group
21
036-21342-002 Rev. E (0505)
HEATING PERFORMANCE DATA
E4TS060S06A WITH N1VSD2006 / G2FD061S21 - HIGH CFM 2-CYLINDER OPERATION
ID CFM
OD DB
1540
ID DB (°F)
60
70
80
60
70
80
60
70
80
60
70
80
60
70
80
60
70
80
60
47
35
17
7
-3
MBTUH1,2
65.76
63.45
61.15
56.89
54.00
51.10
46.70
43.54
40.38
29.71
28.44
27.16
21.86
20.78
19.70
13.59
12.92
12.25
1860
KW
4.68
4.98
5.27
4.31
4.51
4.71
3.92
4.04
4.17
3.45
3.50
3.55
2.75
2.86
2.96
2.44
2.53
2.62
2075
MBTUH1,2
66.22
64.33
62.43
57.80
55.00
52.20
47.54
44.43
41.32
30.61
29.20
27.79
22.24
21.19
20.14
13.84
13.18
12.53
MBTUH1,2
66.68
65.20
63.72
58.70
56.00
53.30
48.37
45.31
42.25
31.51
29.96
28.41
22.63
21.60
20.57
14.08
13.44
12.80
KW
4.71
5.02
5.33
4.39
4.61
4.82
4.04
4.17
4.30
3.58
3.68
3.79
2.81
2.94
3.06
2.50
2.61
2.72
KW
4.74
5.07
5.40
4.47
4.70
4.93
4.16
4.30
4.44
3.70
3.86
4.02
2.87
3.02
3.16
2.56
2.68
2.81
E4TS060S06A WITH N1VSD2006 / G2FD061S21 - LOW CFM 1-CYLINDER OPERATION
ID CFM
OD DB
1000
1200
1350
ID DB (°F)
MBTUH1,2
KW
MBTUH1,2
KW
MBTUH1,2
KW
60
70
80
60
70
80
60
70
80
36.04
33.56
31.08
26.89
25.57
24.26
17.25
17.10
16.94
2.14
2.28
2.42
2.03
2.13
2.24
1.86
1.93
2.00
36.57
34.11
31.64
28.43
26.60
24.77
19.73
18.56
17.39
2.14
2.28
2.42
2.03
2.14
2.25
1.88
1.95
2.02
37.10
34.65
32.20
29.97
27.63
25.28
22.20
20.02
17.84
2.13
2.28
2.42
2.04
2.15
2.26
1.89
1.97
2.04
60
47
35
For notes see Page 11.
Multipliers for determining the performance with other indoor sections.
2-CYLINDER OPERATION
Air Handler
Coil
N1VSD20
G1FD060S24
F(2,3)FV060
Variable Speed
Coil
Furnace
1-CYLINDER OPERATION
HIGH CFM
LOW CFM
MBTUH KW MBTUH KW
Coil
G1FD060S24
0.98
1.00
0.93
0.98
N1VSD20
0.98
1.00
0.93
0.98
F(2,3)FV060
MBTUH KW MBTUH KW
P1XDD20V112
G2FD060S24
0.98
0.99
P1XDD20V112
G2FD061H24
1.00
0.99
P1XUD20V112
G1UA060S24
0.98
0.98
P1XUD20V112
G1FA060S24
0.98
0.98
P1XUD20V112
G2FD060S24
0.98
0.98
P1XUD20V112
G2FD061H24
1.00
0.98
0.90
LOW CFM
Air Handler
Variable Speed
Coil
Furnace
MBTUH
KW
0.89
0.91
0.88
0.90
MBTUH
KW
0.88
0.95
0.94
P1XDD20V112
G2FD060S24
0.92
0.95
P1XDD20V112
G2FD061H24
0.88
0.92
0.90
0.93
P1XUD20V112
G1UA060S24
0.87
0.95
0.90
0.93
P1XUD20V112
G1FA060S24
0.87
0.95
0.90
0.93
P1XUD20V112
G2FD060S24
0.87
0.95
0.92
0.93
P1XUD20V112
G2FD061H24
0.87
0.93
NOTE: KW RATING IS FOR OUTDOOR AND INDOOR UNITS.
22
Unitary Products Group
036-21342-002 Rev. E (0505)
MATCHING INDOOR COMPONENTS
G1UA
UPFLOW
G2FD*
MULTI-POSITION
(UPFLOW, HORIZONTAL
AND DOWNFLOW)
G1FA
FULL CASED
AIR HANDLERS - FOR NON-FURNACE APPLICATIONS
N1VS
MODULAR BLOWER
(UPFLOW, HORIZONTAL
AND DOWNFLOW)
G2FD
COIL
Unitary Products Group
F2FV
FAN COIL UNITS
(UPFLOW, HORIZONTAL)
23
NOTES
Subject to change without notice. Printed in U.S.A.
Copyright © by York International Corp. 2005. All rights reserved.
Unitary
Product
Group
036-21342-002 Rev. E (0505)
Supersedes: 036-21342-002 Rev. D (1104)
5005
York
Drive
Norman
OK
73069