Download Tecumseh RKA5512YXG Performance Data Sheet

Transcript
Performance Data Sheet
RKA5512YXG
General Information
Model
RKA5512YXG
Refrigerant
R-134a
Test Condition
EN12900 ASERCOM
Performance Test Voltage
400V 3~ 50HZ
Return Gas
10K (18°F) SUPERHEAT
Motor Type
3PH
Performance Information
Condensing Temperature (°C)
Evap
Temp (°C)
30
Watts
(Capacity)
-25
403
Amps
2.05
814
682
Watts (Power)
421
492
Amps
2.05
2.01
941
821
(Capacity)
-23.3
Watts
(Capacity)
-20
451
535
Amps
2.05
2.03
1180
1070
915
Watts (Power)
488
586
660
Amps
2.05
2.04
2.07
1490
1380
1200
1010
Watts (Power)
516
623
718
793
Amps
2.05
2.06
2.11
2.18
1740
1610
1420
1200
Watts
Watts
(Capacity)
-10
Watts
(Capacity)
-6.7
Watts (Power)
533
642
747
841
Amps
2.05
2.07
2.13
2.22
1880
1750
1550
1310
Watts (Power)
541
651
760
862
Amps
2.04
2.08
2.14
2.24
2350
2190
1950
1660
Watts
(Capacity)
-5
Watts
(Capacity)
0
60
Watts (Power)
(Capacity)
-15
50
757
Watts (Power)
Watts
40
Watts (Power)
566
673
793
916
Amps
2.04
2.09
2.17
2.29
Watts
2930
2720
2430
2080
Watts (Power)
595
695
818
957
Amps
2.03
2.10
2.20
2.34
3210
2990
2670
2280
(Capacity)
5
Watts
(Capacity)
7.2
Watts (Power)
610
705
829
973
Amps
2.02
2.10
2.21
2.36
3600
3350
2990
2560
Watts (Power)
633
720
842
991
Amps
2.02
2.11
2.23
2.38
4400
4080
3650
3130
Watts (Power)
683
752
867
1020
Amps
2.00
2.11
2.25
2.43
CAPACITY
POWER
CURRENT
MASS FLOW
Watts
(Capacity)
10
Watts
(Capacity)
15
COEFFICIENTS
C1
2.115276E+03 3.969978E+02 2.083010E+00
C2
1.110061E+02 2.219743E+01 -1.315190E-02
C3
3.149417E+01
1.136716E-01
-6.455860E-03
C4
2.656230E+00
4.139570E-01
-4.190000E-05
C5
1.288696E-01
-9.138685E-01
3.840230E-04
C6
-9.164568E-01
2.251823E-01
1.641760E-04
C7
1.287802E-02
5.496900E-03
0.000000E+00
C8
-2.394002E-02 -1.087205E-02 0.000000E+00
C9
-1.173955E-02
1.165829E-02
C10
4.424094E-03
-1.383704E-03 0.000000E+00
0.000000E+00
Value = C1 + C2 * Te + C4 * Te^2 + C7 * Te^3 + (C3 + C5 * Te + C8 * Te^2) * Tc + (C6 + C9 * Te) * Tc^2 + C10 * Tc^3
Te = Evaporator Temperature
Tc = Condensing Temperature
Performance Data Sheet
RKA5512YXG
General Information
Model
RKA5512YXG
Refrigerant
R-134a
Test Condition
EN12900 ASERCOM
Performance Test Voltage
460V 3~ 60HZ
Return Gas
10K (18°F) SUPERHEAT
Motor Type
3PH
Performance Information
Condensing Temperature (°C)
Evap
Temp (°C)
30
Watts
(Capacity)
-25
455
Amps
1.83
998
825
Watts (Power)
478
570
Amps
1.83
1.84
1160
997
(Capacity)
-23.3
Watts
(Capacity)
-20
517
617
Amps
1.84
1.85
1460
1300
1110
Watts (Power)
566
677
779
Amps
1.84
1.87
1.93
1840
1670
1460
1220
Watts (Power)
606
724
841
953
Amps
1.85
1.89
1.96
2.08
2140
1960
1720
1450
Watts
Watts
(Capacity)
-10
Watts
(Capacity)
-6.7
Watts (Power)
627
750
876
1000
Amps
1.86
1.90
1.98
2.11
2310
2120
1870
1580
Watts (Power)
638
762
891
1020
Amps
1.86
1.91
2.00
2.13
2880
2650
2350
2010
Watts
(Capacity)
-5
Watts
(Capacity)
0
60
Watts (Power)
(Capacity)
-15
50
924
Watts (Power)
Watts
40
Watts (Power)
665
793
933
1080
Amps
1.88
1.93
2.03
2.17
Watts
3560
3290
2930
2500
Watts (Power)
691
819
967
1130
Amps
1.89
1.96
2.07
2.22
3900
3600
3210
2750
(Capacity)
5
Watts
(Capacity)
7.2
Watts (Power)
702
830
981
1150
Amps
1.90
1.97
2.09
2.25
4370
4030
3590
3090
Watts (Power)
718
844
998
1170
Amps
1.91
1.99
2.11
2.28
5310
4890
4370
3760
Watts (Power)
748
870
1030
1210
Amps
1.93
2.02
2.15
2.33
CAPACITY
POWER
CURRENT
MASS FLOW
Watts
(Capacity)
10
Watts
(Capacity)
15
COEFFICIENTS
C1
2.843862E+03 4.026426E+02 1.955900E+00
C2
1.351737E+02 1.257171E+01 -4.223810E-03
C3
2.398177E+01 4.941023E+00 -9.012800E-03
C4
3.054194E+00
1.043052E-01
4.320000E-05
C5
2.684804E-02
-4.583793E-01
2.336730E-04
C6
-8.918355E-01
1.480729E-01
2.109700E-04
C7
1.533946E-02
3.585264E-03
0.000000E+00
C8
-2.686276E-02 -4.722892E-03 0.000000E+00
C9
-1.247973E-02
7.132122E-03
C10
4.331162E-03
-6.977550E-04 0.000000E+00
0.000000E+00
Value = C1 + C2 * Te + C4 * Te^2 + C7 * Te^3 + (C3 + C5 * Te + C8 * Te^2) * Tc + (C6 + C9 * Te) * Tc^2 + C10 * Tc^3
Te = Evaporator Temperature
Tc = Condensing Temperature