Performance Data Sheet
RKA5512CXC
General Information
Model
RKA5512CXC
Refrigerant
R-407C
Test Condition
ASHRAE
Performance Test Voltage
240V ~ 50HZ
Return Gas
18.3°C (65°F) RETURN GAS
Motor Type
PSC
Performance Information
Condensing Temperature (°F)
Evap Temp (°F)
Btu/h
80
90
2690
2670
Watts
465
484
Amps
2.24
2.33
100
110
120
130
140
-15
Lb/h
37.5
37.0
Btu/h
3100
3030
2950
Watts
479
502
526
Amps
2.28
2.39
2.50
-10
Lb/h
42.1
41.6
40.9
Btu/h
3580
3450
3320
3180
Watts
491
519
548
576
Amps
2.31
2.43
2.56
2.69
-5
Lb/h
47.5
46.8
46.1
45.3
Btu/h
4130
3940
3750
3560
3370
Watts
501
534
567
601
635
Amps
2.33
2.47
2.62
2.77
2.92
Lb/h
53.6
52.8
52.0
51.1
50.1
0
Btu/h
4750
4500
4260
4010
3750
Watts
508
546
585
623
662
Amps
2.35
2.51
2.67
2.84
3.01
Lb/h
60.5
59.5
58.6
57.6
56.5
5
Btu/h
5430
5130
4830
4520
4210
3900
3580
Watts
513
557
600
644
687
731
776
Amps
2.36
2.54
2.72
2.90
3.09
3.28
3.47
Lb/h
68.1
67.0
65.9
64.8
63.6
62.4
61.1
10
Btu/h
6180
5820
5460
5100
4730
4360
3990
Watts
517
565
613
662
710
759
809
Amps
2.36
2.56
2.76
2.96
3.17
3.38
3.59
15
Lb/h
76.5
75.3
74.1
72.8
71.5
70.1
68.7
Btu/h
7010
6590
6170
5750
5320
4900
4470
Watts
517
571
624
678
731
786
840
Amps
2.36
2.58
2.80
3.02
3.24
3.47
3.70
Lb/h
85.6
84.3
82.9
81.5
80.1
78.6
77.1
20
Btu/h
7910
7430
6950
6470
5990
5500
5010
Watts
516
574
633
691
750
809
869
Amps
2.35
2.59
2.83
3.07
3.31
3.55
3.80
Lb/h
95.6
94.1
92.6
91.1
89.5
87.9
86.2
25
Btu/h
8880
8340
7800
7260
6720
6170
5630
Watts
512
575
639
703
767
831
895
Amps
2.34
2.59
2.85
3.11
3.37
3.63
3.90
Lb/h
106
105
103
101
99.6
97.9
96.1
Btu/h
9920
9320
8720
8120
7520
6920
6310
30
Watts
506
574
643
712
781
850
920
Amps
2.31
2.59
2.87
3.14
3.42
3.70
3.99
35
Lb/h
118
116
114
112
111
109
107
Btu/h
11000
10400
9720
9060
8390
7730
7060
Watts
497
571
645
719
793
867
942
Amps
2.29
2.58
2.88
3.17
3.47
3.77
4.07
40
Lb/h
130
128
126
124
122
120
118
Btu/h
12200
11500
10800
10100
9340
8620
7890
Watts
485
565
644
723
803
882
962
Amps
2.25
2.56
2.88
3.19
3.51
3.83
4.15
Lb/h
143
141
139
137
135
133
130
45
Btu/h
13500
12700
11900
11200
10400
9580
8790
Watts
471
556
640
725
810
894
979
Amps
2.21
2.54
2.88
3.21
3.55
3.88
4.22
Lb/h
157
155
153
150
148
146
143
50
Btu/h
14900
14000
13200
12300
11500
10600
9770
Watts
455
545
635
724
814
904
994
Amps
2.16
2.51
2.87
3.22
3.58
3.93
4.29
Lb/h
172
170
167
165
162
160
157
CAPACITY
POWER
CURRENT
MASS FLOW
55
COEFFICIENTS
C1
5.580009E+03 2.385200E+02 1.203175E+00 5.940035E+01
C2
2.094416E+02 -6.380422E+00 -2.596218E-02 1.514888E+00
C3
-1.818532E+01 3.282380E+00
1.413109E-02
-7.371003E-02
C4
1.462606E+00 -4.852588E-02 -1.451335E-04
1.601374E-02
C5
-1.193500E+00 1.029567E-01
3.854484E-04
-3.050437E-03
C6
7.339149E-03
-5.327443E-04 -5.205057E-06
1.131407E-04
C7
1.312350E-03
-5.891005E-05 -1.676880E-07
1.249187E-05
C8
-1.276345E-03
6.629922E-05
3.183661E-07
-1.313027E-05
C9
3.484368E-04
-2.068137E-05 -1.369010E-07
3.985909E-06
C10
-7.988030E-05
5.744361E-06
-1.199335E-06
5.512130E-08
Value = C1 + C2 * Te + C4 * Te^2 + C7 * Te^3 + (C3 + C5 * Te + C8 * Te^2) * Tc + (C6 + C9 * Te) * Tc^2 + C10 * Tc^3
Te = Evaporator Temperature
Tc = Condensing Temperature