Download Tecumseh AJA2423ZXDHS Performance Data Sheet
Transcript
AJA2423ZXDHS_REV1 TPC - November 21, 2013 TECUMSEH OUTDOOR CONDENSING UNIT Model BOM Air Cooled Application Refrigerant Volts-Hz-Ph AJA2423ZXDHS 32L511-2E* 1/2 HP Low Temp R404A 208-230/60/1 28.94 27.94 27.35 23.50 26.55 26.08 2.96 LIQUID 3/8" SUCTION 1/2" Overall Dimensions, inch (mm) L W H 26.55 (674) 28.94 (735) 26.08 (662) AJA2423ZXDHS Line connections Suction Liquid 1/2" 3/8" Pumpdown o 90% @ 90 F 15.70 lbs Air flow SCFM 750 Oil Ch. Oz. 26.4 Gross weight Lbs. (kg) 200 (91) Factory charge 20 psig dry air, MUST BE EVACUATED Evaporator T, °F -35 -30 -25 -20 -15 -10 -5 0 5 10 PSIG 8.0 10.7 14.0 17.1 19.3 24.5 28.8 33.5 36.5 43.7 Ambient Temperatures 85°F 90°F 95°F BTUH Watts Cond T BTUH Watts Cond T BTUH Watts Cond T 1100 500 89 1000 490 93 900 490 97 1400 540 89 1300 530 93 1200 530 98 1700 580 90 1600 580 94 1500 580 99 2000 620 91 1900 620 95 1800 620 100 2400 670 91 2300 670 96 2100 670 101 2800 710 92 2600 710 97 2500 720 102 3200 760 93 3000 760 98 2900 770 103 3700 800 94 3500 810 99 3300 810 104 4200 850 96 3900 850 100 3700 860 105 4700 890 97 4400 900 101 4200 910 106 o o Performance @ 60 Hz, Return gas 40 F , SubCooling 5 F PRELIMINARY DATA *OPTION CODE: See reverse side for Available Options 100°F BTUH Watts Cond T 800 480 103 1100 520 103 1300 570 104 1600 620 105 2000 670 106 2300 720 107 2700 770 108 3100 820 109 3500 870 110 4000 920 111 110°F BTUH Watts Cond T 700 460 112 900 510 113 1100 560 114 1400 610 115 1700 670 116 2000 720 118 2300 780 119 2700 830 120 3100 890 121 3500 940 122 AJA2423ZXDHS_REV1 TPC - November 21, 2013 Parts/Specifications STANDARD Unit BOM Unit MODEL 32L511-2E AJA2423ZXDHS Refrigeration Range Design Pressure Low / High Volts - HZ - Ph Voltage Range Min. Circuit Ampacity Max. Fuse Size -35°F to 10°F 181 / 450 208-230V ~ 60HZ 187 - 253 5.20 15 Compressor MODEL Compressor BOM Compressor LRA Compressor RLA AJA2419ZXD AJ303ET-336-P2 34 3.46 OverLoad Replacement Kit - O/L Relay Replacement Kit - Relay Run Capacitor Run Capacitor Rating Start Capacitor Start Capacitor Rating Contactor 8300MRTL62 K90-09 820ARR3L26 Unit Drawing Wiring Diagram Wiring Diagram (A or F opt.) 85PR370E36 15 MFD, 370 V 85PS330D71 161-193 MFD, 330 V 91014B DGU1893-L112 WD21-1T2 AVAILABLE OPTIONS Fan Motor Replacement Fan Motor Fan Motor Qty Fan Motor RLA Fan Blade Fan Guard Shroud 810F050C20 50W230 1 0.7 51568-1 70831 70727-2 High Pressure Switch Low Pressure Control Dual Pressure Conrol 84095-2L 84026-2 Head Master Valve Check Valve Process Valve Discharge Valve (Base) Liquid Valve (Base) Liquid Valve (Receiver) Suction Valve (Base) Suction Valve (Rotolock) 70083 56626 AVAILABLE ACCESSORIES Solenoid Valve (supplied loose) KSVC-264 Hail Louver Assy LLPG-101 56618 56500-K06 31590 56500-K08 31582-3K REPLACEMENT PARTS Receiver Heater (R option) 92124-2 Receiver Thermostat (R option) 84102-2 Fixed Fan Control (F option) Adjustable Fan Control (A option) Condenser Receiver Accumulator Liquid Filter Sight Glass Suction Filter CrankCase Heater 50857-1 51082-1K TK00014000 70139 70084-S 704-20001 92123-1 Defrost Timer (T1 or T2 option) Defrost Heater Contactor and Auxiliary Switch (T2 opt.) 32Lxxxx-2ER(F)ATnD R Heated/Insulated Receiver F Fixed Fan Control A Adjustable Fan Control T1 Air Defrost Timer T2 Electrical Defrost Timer & Defrost Heater Contactor D Disconnect Switch (nonfused) Disconnect (D option) 84110 91014B and 91014-AUX