Download TDK J Series JBW User's Manual

Transcript
(1/30)
Conformity to RoHS Directive
AC Input
Single Output, General-Purpose, UL/C-UL/TÜV Approved
J Series JBW(10 to 150W)
FEATURES
• Compact and low price.
• Wide input voltage range.
• Safety standards approved.
• Corresponds to products with CE marking.
• Full lineup of output power 10 to 150W
• Open frame
• Meets conducted noise standard FCC Class B.
• Warranty period: 3 years
• Specific bromine inflammable materials (PBDPEs, PBBs) are
not included in use.
• It is a product conforming to RoHS directive.
APPLICATIONS
Measuring equipment, robotics, automation equipment, information processing equipment, security systems, amusement equipment, etc.
PRODUCT IDENTIFICATION
SAFETY STANDARDS
UL60950-1, CSA C22.2 No.60950-1(C-UL), EN60950-1(TÜV),
approved.
EMC REGULATIONS
• FCC Class-B, VCCI Class-B, EN-55011-B and EN55022-B
meet.
• Harmonic current requirement EN61000-3-2 meet(50 to 150W).
JBW
(1)
05
(2)
–
2R0
(3)
(1)Series name
(2)Rated output voltage
(3)Rated output current(R: Decimal point)
PART NUMBERS AND RATINGS
Output voltage
(V)
5
12
15
24
10W Type
Current(A)
2
0.9
0.7
0.5
Part No.
JBW05-2R0
JBW12-0R9
JBW15-0R7
JBW24-0R5
15W Type
Current(A)
3
1.3
1
0.7
Part No.
JBW05-3R0
JBW12-1R3
JBW15-1R0
JBW24-0R7
30W Type
Current(A)
6
2.5
2
1.3
Part No.
JBW05-6R0
JBW12-2R5
JBW15-2R0
JBW24-1R3
Output voltage
(V)
5
12
15
24
48
75W Type
Current(A)
15
6.3
5.0
3.2
—
Part No.
JBW05-15R
JBW12-6R3
JBW15-5R0
JBW24-3R2
—
100W Type
Current(A)
20
8.5
6.7
4.3
—
Part No.
JBW05-20R
JBW12-8R5
JBW15-6R7
JBW24-4R3
—
150W Type
Current(A)
30
12.5
10
6.3
3.2
Part No.
JBW05-30R
JBW12-12R
JBW15-10R
JBW24-6R3
JBW48-3R2
50W Type
Current(A)
10
4.3
3.5
2.1
Part No.
JBW05-10R
JBW12-4R3
JBW15-3R5
JBW24-2R1
• 3.3 and 48V models(75 to 150W type) are made to order.
• Conformity to RoHS Directive: This means that, in conformity with EU Directive 2002/95/EC, lead, cadmium, mercury, hexavalent chromium, and specific
bromine-based flame retardants, PBB and PBDE, have not been used, except for exempted applications.
• All specifications are subject to change without notice.
004-02 / 20070523 / ea122_jbw.fm
(2/30)
JBW10W Type
SPECIFICATIONS AND STANDARDS
Part No.
Rated output voltage and current∗
Maximum output power
Input conditions
Input voltage Eac/Edc
Input frequency
Input current
Fuse rating
Surge current
Leakage current
Power factor
Efficiency
W
V
Hz
A
A
A
mA
%
%
Output characteristics
Output voltage Edc
V
Voltage variable range Edc
V
Maximum output current
A
Minimum output current
A
Overvoltage threshold Edc
V
Overcurrent threshold
A
Source effect
%
Load effect
%
Voltage
Temperature effect
%
stability
Drift(Time effect)
%
Recovery
%
Ripple Ep-p
mV
Ripple noise Ep-p
mV
Start up time
ms
Hold up time
ms
Auxiliary functions
Indicator display
Overvoltage protection
Overcurrent protection
Remote ON-OFF
Remote sensing
Parallel operation
Series operation
Output voltage external variable function
Standards
Safety standards
Noise terminal voltage
Input harmonics current requirement
Constructions
External dimensions
mm
Weight
g
Mounting method
Case material
JBW05-2R0
5V • 2A
10
JBW12-0R9
12V • 0.9A
10.8
JBW15-0R7
15V • 0.7A
10.5
JBW24-0R5
24V • 0.5A
12
85 to 265[Rating: 100 to 240]/110 to 370
47 to 440[Rating: 50 to 60](Single phase)
0.25typ./0.35max. [AC.100V]0.15typ./0.25max.[AC.240V]
2[AC.250V, built-in]
15typ.(20max.)[AC.100V]30typ.(40max.)[AC.240V] 1st surge current, cold start, reset after 1s minimum.
0.1typ./0.75max.[AC.100V, 60Hz]0.15typ./0.75max.[AC.240V, 60Hz]
0.6typ./0.45typ.[AC.100/240V]
71typ.[AC.100V]
78typ.[AC.100V]
79typ.[AC.100V]
82typ.[AC.100V]
71typ.[AC.240V]
79typ.[AC.240V]
80typ.[AC.240V]
83typ.[AC.240V]
5
12
15
Fixed
Fixed
Fixed
2
0.9
0.7
0
0
0
5.75min.
13.8min.
17.25min.
2.5min.
1.12min.
0.87min.
0.4max.[Within the input voltage range]
0.8max.[0 to 100% load]
1max.[Ambient temperature: –10 to +50°C]
0.4max.[25°C, input and output ratings, after input voltage ON for 30min to 8h]
±4max.[50 to 100% sudden load change]
80max.
120max.
120max.
120max.
150max.
150max.
700max.(200typ.)/700max.(200typ.) [AC.100/240V]
15typ/140typ [AC.100/240V]
24
Fixed
0.5
0
27.6min.
0.62min.
120max.
150max.
No
Zenor diode clamp method, output may latch up depending on the condition.
Fold back type, automatic recovery.
No
No
Impossible
Inpossible
No
UL60950-1, CSA C22.2 No.60950-1(C-UL), EN60950-1(TÜV) approved.
FCC-B, VCCI-B, EN55011-B, EN55022-B meet.
No
21× 36× 95[H× W× L]
50max.
Can be attached to 1 side.
No(PWB Material: CEM3)
∗ Current rating(maximum output current) is determined for –10 to +50°C. Derating is required when used outside this temperature range.
• Optional input, output cable kits are available at a separate price.
• All specifications are subject to change without notice.
004-02 / 20070523 / ea122_jbw.fm
(3/30)
JBW10W Type
SHAPES AND DIMENSIONS
2-ø3.4Mounting holes
95
21
7
5.2
Area For Spacer(ø6.0max.)
3max.
3.5
10
7
3.5
Solder Side
TB1
TB2
+
+
_
_
17.3
29±0.5
7
N
JBW05-2R0
TDK
36
L
Ser. No. LABEL
3.8
16.4
1.6
88±0.5
3.5
GND Pad
Solder Side
7
Dimensions in mm
±1mm : without specified dimensions
TERMINAL DESIGNATION
TB2
TB1
P3
L
P2
N
L
1
N
2
P4
6
5
+
+
_
_
P3
P2
3
P1
Japan Solderless Terminal Co., Ltd.
Input Connector(TB1) VH Series
Output Connector(TB2) XH Series
LCE
Input Connector(TB1) P101 Series
Output Connector(TB2) P221 Series
–
P1
4
Connector made by
+
Power supply side
connector
Cable Side
Housing
Terminal
B3P5-VH-B
B4B-XH-2
VHR-5N
XHP-4
SVH-21T-P1.1
SXH-001T-P0.6
P101-05-2/4
P221-04
H101-05
H221-04
T101
T221-01
Terminal No.
1
2
3
4
5
6
Designations
Input terminal(L)
Input terminal(N)
Frame ground terminal(G)
Ground pad
Output terminal(–)
Output terminal(+)
Option
Set
Part No.
4EU20G054
• All specifications are subject to change without notice.
004-02 / 20070523 / ea122_jbw.fm
(4/30)
JBW15W Type
SPECIFICATIONS AND STANDARDS
Part No.
Rated output voltage and current∗
Maximum output power
Input conditions
Input voltage Eac/Edc
Input frequency
Input current
Fuse rating
Surge current
Leakage current
Power factor
Efficiency
W
V
Hz
A
A
A
mA
%
%
Output characteristics
Output voltage Edc
V
Voltage variable range Edc
V
Maximum output current
A
Minimum output current
A
Overvoltage threshold Edc
V
Overcurrent threshold
A
Source effect
%
Load effect
%
Voltage
Temperature effect
%
stability
Drift(Time effect)
%
Recovery
%
Ripple Ep-p
mV
Ripple noise Ep-p
mV
Start up time
ms
Hold up time
ms
Auxiliary functions
Indicator display
Overvoltage protection
Overcurrent protection
Remote ON-OFF
Remote sensing
Parallel operation
Series operation
Output voltage external variable function
Standards
Safety standards
Noise terminal voltage
Input harmonics current requirement
Constructions
External dimensions
mm
Weight
g
Mounting method
Case material
JBW05-3R0
5V • 3A
15
JBW12-1R3
12V • 1.3A
15.6
JBW15-1R0
15V • 1.0A
15
JAW24-0R7
24V • 0.7A
16.8
85 to 265[Rating: 100 to 240]/110 to 370
47 to 440[Rating: 50 to 60](Single phase)
0.36typ./0.43max.[AC.100V]0.2typ./0.24max.[AC.240V]
2[AC.250V, built-in]
15typ./19.5max.[AC.100V]30typ./41max.[AC.240V] 1st surge current, cold start, reset after 1s minimum.
0.2typ./0.75max.[AC.100V, 60Hz]0.3typ./0.75max.[AC.240V, 60Hz]
0.6typ./0.45typ.[AC.100/240V]
72typ.[AC.100V]
76typ.[AC.100V]
76typ.[AC.100V]
78typ.[AC.100V]
72typ.[AC.240V]
74typ.[AC.240V]
74typ.[AC.240V]
76typ.[AC.240V]
5
12
15
24
Fixed
Fixed
Fixed
Fixed
3
1.3
1
0.7
0
0
0
0
5.75min.
13.8min.
17.25min.
27.6min.
3.15min.
1.37min.
1.05min.
0.74min.
0.4max.[Within the input voltage range]
0.8max.[0 to 100% load]
1max.[Ambient temperature: –10 to +50°C]
0.4max.[25°C, input and output ratings, after input voltage ON for 30min to 8h]
±4max.[50 to 100% sudden load change]
80max.
120max.
120max.
120max.
120max.
150max.
150max.
150max.
200max.(25typ.)/100max.(25typ.)[AC.100/240V]
200max.(40typ.)/100max.(40typ.)[AC.100/240V]
13typ./150typ. [AC.100/240V]
No
Zenor diode clamp method, output may latch up depending on the condition.
Rectangular type, automatic recovery.
No
No
Impossible
Impossible
No
UL60950-1, CSA C22.2 No.60950-1(C-UL), EN60950-1(TÜV) approved.
FCC-B, VCCI-B, EN55011-B, EN55022-B meet.
No
22.6× 50× 95[H× W× L]
80max.
Can be attached to 1 side.
No(PWB Material: CEM3)
∗ Current rating(maximum output current) is determined for –10 to +50°C. Derating is required when used outside this temperature range.
• Optional input, output cable kits are available at a separate price.
• All specifications are subject to change without notice.
004-02 / 20070523 / ea122_jbw.fm
(5/30)
JBW15W Type
SHAPES AND DIMENSIONS
22.6
95
4-ø3.4Mounting holes
+
+
_
_
50
TB3
3.5
7
7
N
43±0.5
TB1
JBW05-3R0
3.8
TDK
5.2
L
3max.
3.5
28
23.7
88±0.5
Ser. No. LABEL
7
18.5
1.6
7
Area For Spacer (ø6.0max.)
GND Pad
Solder Side
Solder Side 3 Places
Dimensions in mm
±1mm : without specified dimensions
TERMINAL DESIGNATION
TB3
TB1
P3
L
P2
N
P1
P4
L
1
N
2
6
5
+
+
_
_
+
P3
P2
–
P1
3
Terminal No.
1
2
3
4
5
6
Designations
Input terminal(L)
Input terminal(N)
Frame ground terminal(G)
Ground pad
Output terminal(–)
Output terminal(+)
Option
Set
Part No.
4EU20G054
4
Connector made by
Japan Solderless Terminal Co., Ltd.
Input Connector(TB1) VH Series
Output Connector(TB3) XH Series
LCE
Input Connector(TB1) P101 Series
Output Connector(TB3) P221 Series
Power supply side
connector
Cable Side
Housing
Terminal
B3P5-VH-B
B4B-XH-2
VHR-5N
XHP-4
SVH-21T-P1.1
SXH-001T-P0.6
P101-05-2/4
P221-04
H101-05
H221-04
T101
T221-01
• All specifications are subject to change without notice.
004-02 / 20070523 / ea122_jbw.fm
(6/30)
JBW30W Type
SPECIFICATIONS AND STANDARDS
Part No.
Rated output voltage and current∗
Maximum output power
Input conditions
Input voltage Eac/Edc
Input frequency
Input current
Fuse rating
Surge current
Leakage current
Power factor
Efficiency
W
V
Hz
A
A
A
mA
%
%
Output characteristics
Output voltage Edc
V
Voltage variable range Edc
V
Maximum output current
A
Minimum output current
A
Overvoltage threshold Edc
V
Overcurrent threshold
A
Source effect
%
Load effect
%
Voltage
Temperature effect
%
stability
Drift(Time effect)
%
Recovery
%
Ripple Ep-p
mV
Ripple noise Ep-p
mV
Start up time
ms
Hold up time
ms
Auxiliary functions
Indicator display
Overvoltage protection
Overcurrent protection
Remote ON-OFF
Remote sensing
Parallel operation
Series operation
Output voltage external variable function
Standards
Safety standards
Noise terminal voltage
Input harmonics current requirement
Constructions
External dimensions
mm
Weight
g
Mounting method
Case material
JBW05-6R0
5V • 6A
30
JBW12-2R5
12V • 2.5A
30
JBW15-2R0
15V • 2A
30
JAW24-1R3
24V • 1.3A
31.2
85 to 265[Rating: 100 to 240]/110 to 370
47 to 440[Rating: 50 to 60](Single phase)
0.65typ./0.86max.[AC.100V]0.35typ./0.48max.[AC.240V]
2[AC.250V, built-in]
15typ./30max.[AC.100V]30typ./60max.[AC.240V] 1st surge current, cold start, reset after 1s minimum.
0.35typ./0.75max.[AC.100V, 60Hz]0.5typ./0.75max.[AC.240V, 60Hz]
0.6typ./0.45typ.[AC.100/240V]
75typ.[AC.100V]
78typ.[AC.100V]
79typ.[AC.100V]
80typ.[AC.100V]
77typ.[AC.240V]
79typ.[AC.240V]
80typ.[AC.240V]
81typ.[AC.240V]
5
12
15
Fixed
Fixed
Fixed
6
2.5
2
0
0
0
5.6min.
13.3min.
16.6min.
6.3min.
2.7min.
2.1min.
0.4max.[Within the input voltage range]
0.8max.[0 to 100% load]
2max.[Ambient temperature: –10 to +50°C]
0.4max.[25°C, input and output ratings, after input voltage ON for 30min to 8h]
±4max.[50 to 100% sudden load change]
80max.
120max.
120max.
120max.
150max.
150max.
650max.(350typ.)/320max.(130typ.)[AC.100/240V]
20typ./160typ.[AC.100/240V]
24
Fixed
1.3
0
26.5min.
1.4min.
120max.
150max.
No
Voltage shut-down type.
Rectangular type(Winker operation), automatic recovery.
No
No
Impossible
Impossible
No
UL60950-1, CSA C22.2 No.60950-1(C-UL), EN60950-1(TÜV) approved.
FCC-B, VCCI-B, EN55011-B, EN55022-B meet.
No
26× 55× 122[H× W× L]
150max.
Can be attached to 1 side.
No(PWB Material: CEM3)
∗ Current rating(maximum output current) is determined for –10 to +50°C. Derating is required when used outside this temperature range.
• Optional input, output cable kits are available at a separate price.
• All specifications are subject to change without notice.
004-02 / 20070523 / ea122_jbw.fm
(7/30)
JBW30W Type
SHAPES AND DIMENSIONS
4-ø3.4Mounting holes
122
GND Pad 2 Places
Solder Side
26
112±0.5
6.5
3max.
30
TB1
45±0.5
55
TB2
_
_
+
+
8
8
L
6.6
JBW05-6R0
TDK
N
8
8
Ser. No. LABEL
5
16
5
21.4
1.6
Area For Spacer (ø6.0max.)
Solder Side 2 Places
Dimensions in mm
±1mm : without specified dimensions
TERMINAL DESIGNATION
4
TB1
P1
L
P2
N
P3
4
TB2
3
P1
N
2
P2
L
1
5
6
Connector made by
Japan Solderless Terminal Co., Ltd.
Input Connector(TB1) VH Series
Output Connector(TB2) VH Series
LCE
Input Connector(TB1) P101 Series
Output Connector(TB2) P101 Series
_
_
+
+
Power supply side
connector
Cable Side
Housing
Terminal
B3P5-VH-B
B4P-VH-B
VHR-5N
VHR-4N
SVH-21T-P1.1
SVH-21T-P1.1
P101-05-2/4
P101-04
H101-05
H101-04
T101
T101
P3
P4
–
+
Terminal No.
1
2
3
4
5
6
Designations
Input terminal(L)
Input terminal(N)
Frame ground terminal(G)
Ground pad
Output terminal(–)
Output terminal(+)
Option
Set
Part No.
4EU20G057
• All specifications are subject to change without notice.
004-02 / 20070523 / ea122_jbw.fm
(8/30)
JBW50W Type
SPECIFICATIONS AND STANDARDS
Part No.
Rated output voltage and current∗1
Maximum output power
W
Input conditions
Input voltage Eac/Edc∗2
V
Input frequency
Hz
Input current
A
Fuse rating
A
Surge current
A
Leakage current
mA
Power factor
%
Efficiency
%
Output characteristics
Output voltage Edc
V
Voltage variable range Edc
V
Maximum output current
A
Minimum output current
A
Overvoltage threshold Edc
V
Overcurrent threshold
A
Source effect
%
Load effect
%
Voltage
Temperature effect
%
stability
Drift(Time effect)
%
Recovery
%
Ripple Ep-p
mV
Ripple noise Ep-p
mV
Start up time
ms
Hold up time
ms
Auxiliary functions
Indicator display
Overvoltage protection
Overcurrent protection
Remote ON-OFF
Remote sensing
Parallel operation
Series operation
Output voltage external variable function
Standards
Safety standards
Noise terminal voltage
Input harmonics current requirement
Constructions
External dimensions
mm
Weight
g
Mounting method
Case material
JBW05-10R
5V • 10A
50
JBW12-4R3
12V • 4.3A
51.6
JBW15-3R5
15V • 3.5A
52.5
85 to 265[Rating: 100 to 240]/120 to 375
47 to 66[Rating: 50 to 60](Single phase)
0.7typ./0.88max. [AC.100V]0.35typ./0.5max.[AC.240V]
3.15[AC.250V, built-in]
15typ.(30max.)[AC.100V]40typ.(60max.)[AC.240V] cold start
0.35typ./0.75max.[AC.100V, 60Hz]0.5typ./0.75max.[AC.240V, 60Hz]
0.99typ./0.93typ.[AC.100/240V]
77typ.[AC.100V]
80typ.[AC.100V]
80typ.[AC.100V]
79typ.[AC.240V]
81typ.[AC.240V]
81typ.[AC.240V]
5
12
15
4.5 to 5.5
10.8 to 13.2
13.5 to 16.5
10
4.3
3.5
0
0
0
5.75 to 6.9
13.8 to 16.8
17.2 to 21
10.5min.
5.4min.
4.4min.
0.4max.[Within the input voltage range]
0.8max.[0 to 100% load]
1max.[Ambient temperature: –10 to +50°C]
0.4max.[25°C, input and output ratings, after input voltage ON for 30min to 8h]
±4max.[50 to 100% sudden load change]
80max.
120max.
120max.
120max.
150max.
150max.
500max.(400typ.)/500max.(400typ.) [AC.100/240V]
20typ./20typ. [AC.100/240V]
JBW24-2R1
24V • 2.1A
50.4
81typ.[AC.100V]
83typ.[AC.240V]
24
21.6 to 26.4
2.1
0
27.6 to 33.6
2.7min.
120max.
150max.
No
Voltage shut-down type.
Rectangular type, automatic recovery.
No
No
Impossible
Possible
No
UL60950-1, CSA C22.2 No.60950-1(C-UL), EN60950-1(TÜV) approved.
FCC-B, VCCI-B, EN55011-B, EN55022-B meet.
EN61000-3-2 meet.
26× 55× 190[H× W× L]
220max.
Can be attached to 1 side.
No(PWB Material: CEM3)
∗1 Current
rating(maximum output current) is determined for –10 to +50°C. Derating is required when used outside this temperature range.
note that the deterioration of parts is occasionally caused when operating for a long time(over 10 minutes) with the voltage below the range of the
input voltage.
• Optional input, output cable kits are available at a separate price.
∗2 Please
• All specifications are subject to change without notice.
004-02 / 20070523 / ea122_jbw.fm
(9/30)
JBW50W Type
SHAPES AND DIMENSIONS
GND Pad 2 Places
Solder Side
4-ø4 Mounting holes
190
26
35.7
180±0.5
3max.
12.1
5
5
N
45±0.5
Ser. No. LABEL
TB1
_
_
+
+
47.7
5.5
8
5
8
8
7.1
17.2
55
TB2
L
5
21.4
1.6
8
Area For Spacer (ø6max.)
Solder Side 2 Places
RATING LABEL
JBW05-10R
TDK
Dimensions in mm
±1mm : without specified dimensions
TERMINAL DESIGNATION
4
TB1
4
7
TB2
3
P4
P3
N
P2
N
P1
L
L
2
1
5
6
_
_
+
+
–
P3
P2
P1
+
Terminal No.
1
2
3
4
5
6
7
Connector made by
Japan Solderless Terminal Co., Ltd.
Input Connector(TB1) VH Series
Output Connector(TB2) VH Series
LCE
Input Connector(TB1) P101 Series
Output Connector(TB2) P101 Series
Power supply side
connector
Cable Side
Housing
Terminal
B3P5-VH-B
B4P-VH-B
VHR-5N
VHR-4N
SVH-21T-P1.1
SVH-21T-P1.1
P101-05-2/4
P101-04
H101-05
H101-04
T101
T101
Option
Set
Designations
Input terminal(L)
Input terminal(N)
Frame ground terminal(G)
Ground pad
Output terminal(–)
Output terminal(+)
Output voltage variable
volume
Part No.
4EU20G057
• All specifications are subject to change without notice.
004-02 / 20070523 / ea122_jbw.fm
(10/30)
JBW75W Type
SPECIFICATIONS AND STANDARDS
Part No.
Rated output voltage and current
Maximum output power
Input conditions
Input voltage Eac/Edc
Input frequency
Input current
Fuse rating
Surge current
Leakage current
Power factor
Efficiency
W
V
Hz
A
A
A
mA
%
Output characteristics
Output voltage Edc
V
Voltage variable range Edc
V
Maximum output current
A
Overvoltage threshold Edc
V
Overcurrent threshold
A
Source effect
%
Load effect
%
Voltage
Temperature effect
%
stability
Drift(Time effect)
%
Recovery
%
Ripple Ep-p
mV
Ripple noise Ep-p
mV
Start up time
ms
Hold up time
ms
Auxiliary functions
Indicator display
Overvoltage protection
Overcurrent protection
Remote ON-OFF
Remote sensing
Standards
Safety standards
Noise terminal voltage
Input harmonics current requirement
CE marking
Constructions
External dimensions
mm
Weight
g
Mounting method
Case material
JBW05-15R
5V • 15A
75
JBW12-6R3
12V • 6.3A
75.6
85 to 265[Rating: 100-240]/120 to 370
47 to 66
1.6/0.8max.[100-240V]
3.15
30/60max.[100-240V]
0.75/0.75max.[AC.100V(DENAN)/240V(UL, IEC)]
0.99/0.95typ.[100-240V]
75/77typ.
78/80typ.
[100-240V]
[100-240V]
JBW15-5R0
15V • 5.0A
75
JBW24-3R2
24V • 3.2A
76.8
79/81typ.
[100-240V]
82/84typ.
[100-240V]
5
12
15
4.5 to 5.5
10.8 to 13.2
13.5 to 16.5
15
6.3
5.0
5.75 to 6.9
13.8 to 16.8
17.2 to 21
15.8min.
6.6min.
5.2min.
0.4max.[Within the input voltage range]
0.8max.[0 to 100% load]
1max.[Ambient temperature: –10 to +60°C]
0.4max.[25°C, input and output ratings, after input voltage ON for 30min to 8h]
±4max.[50 to 100% sudden load change]
80
120
120
120
150
150
500max.(400typ.)/250max.(200typ.)[AC.100/240V]
20typ.[100-240V]
24
21.6 to 26.4
3.2(Peak4.2)
27.6 to 33.6
4.4min.
120
150
No
Voltage shut-down type(Latch).
Rectangular type, automatic recovery.
No
No
UL60950-1, CSA C22.2 No.60950-1(C-UL), EN60950-1(TÜV) approved.
FCC-B, VCCI-B, EN55011-B, EN55022-B meet.
EN61000-3-2
Planned compliance.
32× 55× 222[H× W× L]
290max.
Can be attached to 1 side.
CEM3
• All specifications are subject to change without notice.
004-02 / 20070523 / ea122_jbw.fm
(11/30)
JBW75W Type
SHAPES AND DIMENSIONS
29
222
5
212±0.5
1.6
5
3max.
5
4-ø3.5
(4.5)
CP1
CP2
(25.9)
9max.
5
6
(50.9)
1
(5.3)
(43.2)
1
(33)
3
45±0.5
55
5
(45.9)
9max.
Area for spacer(ø6max.)
Solder Side(2 Places)
Ground pattern area(ø6max.)
Solder Side(2 Places)
Dimensions in mm
±1mm : without specified dimensions
TERMINAL DESIGNATION
CP2
CP1
P1
L
P1
P3 N
5
P5
3 CP1
· Japan Solderless Terminal Co., Ltd.
VH Series B3P5-VH-B
P2
1
2
CP2 4 3
5
6
1
–
P3
P4
P5
+
P6
· Japan Solderless Terminal Co., Ltd.
VH Series B6P-VH-B
Connector made by
Japan Solderless Terminal Co., Ltd.
Input Connector(CP1)VH Series
Output Connector(CP2)VH Series
Power supply side
connector
Cable Side
Housing
Terminal
B3P5-VH-B
B6P-VH-B
VHR-5N
VHR-6N
SVH-21T-P1.1
SVH-21T-P1.1
Option
Set
Part No.
4EU20G085
• All specifications are subject to change without notice.
004-02 / 20070523 / ea122_jbw.fm
(12/30)
JBW100W Type
SPECIFICATIONS AND STANDARDS
Part No.
Rated output voltage and current
Maximum output power
Input conditions
Input voltage Eac/Edc
Input frequency
Input current
Fuse rating
Surge current
Leakage current
Power factor
Efficiency
W
V
Hz
A
A
A
mA
%
Output characteristics
Output voltage Edc
V
Voltage variable range Edc
V
Maximum output current
A
Overvoltage threshold Edc
V
Overcurrent threshold
A
Source effect
%
Load effect
%
Voltage
Temperature effect
%
stability
Drift(Time effect)
%
Recovery
%
Ripple Ep-p
mV
Ripple noise Ep-p
mV
Start up time
ms
Hold up time
ms
Auxiliary functions
Indicator display
Overvoltage protection
Overcurrent protection
Remote ON-OFF
Remote sensing
Standards
Safety standards
Noise terminal voltage
Input harmonics current requirement
CE marking
Constructions
External dimensions
mm
Weight
g
Mounting method
Case material
JBW05-20R
5V • 20A
100
JBW12-8R5
12V • 8.5A
102
85 to 265[Rating: 100-240]/120 to 370
47 to 66
1.8/1.0max.[100-240V]
5
30/60max.[100-240V]
0.75/0.75max.[AC.100V(DENAN)/240V(UL, IEC)]
0.99/0.95typ.[100-240V]
78/80typ.
80/82typ.
[100-240V]
[100-240V]
JBW15-6R7
15V • 6.7A
100.5
JBW24-4R3
24V • 4.3A
103.2
80/82typ.
[100-240V]
82/85typ.
[100-240V]
5
12
15
±10%
±10%
±10%
20
8.5
6.7
5.75 to 6.9
13.8 to 16.8
17.2 to 21
21.0min.
10.6min.
8.38min.
0.4max.[Within the input voltage range]
0.8max.[0 to 100% load]
1max.[Ambient temperature: –10 to +60°C]
0.4max.[25°C, input and output ratings, after input voltage ON for 30min to 8h]
±4max.[50 to 100% sudden load change]
80
120
120
120
150
150
500max.(400typ.)/500max.(300typ.)[AC.100/240V]
20typ.[100-240V]
24
±10%
4.3(Peak5)
27.6 to 33.6
5.38min.
120
150
No
Voltage shut-down type(Latch).
Rectangular type, automatic recovery.
No
No
UL60950-1, CSA C22.2 No.60950-1(C-UL), EN60950-1(TÜV) approved.
FCC-B, VCCI-B, EN55011-B, EN55022-B meet.
EN61000-3-2
Planned compliance.
35× 62× 222[H× W× L]
400max.
Can be attached to 1 side.
FR4
• All specifications are subject to change without notice.
004-02 / 20070523 / ea122_jbw.fm
(13/30)
JBW100W Type
SHAPES AND DIMENSIONS
222
212±0.5
Input
connector
32
1.6
Output voltage
adjustment trimmer
3max.
9
5.0
CP2
3 CP1
5
9max.
1
(51.5)
5
(4.7)
42.0
(17.9)
62
52±0.5
(5.8)
1
8
Output voltage connector
9max.
Area for spacer(ø6max.)
Solder Side(3 Places)
(32.7)
Ground pattern area(ø6max.)
Solder Side(1 Place)
Dimensions in mm
±1mm : without specified dimensions
TERMINAL DESIGNATION
CP2
4
P1
7
5
3
1
3
2 CP1
1
P3
1
5
P5
6
L
P6
8
P3 N
P7
P5
Japan Solderless Terminal Co., Ltd.
Input Connector(CP1)VH Series
Output Connector(CP2)VH Series
+
Terminal No.
1
2
3
4
5
6
7
Designations
Input terminal(L)
Input terminal(N)
Frame ground terminal(G)
Ground pad
Output terminal(–)
Output terminal(+)
Output voltage setting trim(+)
P8
· Japan Solderless Terminal Co., Ltd.
VH Series B8P-VH-B
· Japan Solderless Terminal Co., Ltd.
VH Series B3P5-VH-B
Connector made by
–
P4
CP2
CP1
P1
P2
Power supply side
connector
Cable Side
Housing
Terminal
B3P5-VH-B
B8P-VH-B
VHR-5N
VHR-8N
SVH-21T-P1.1
SVH-21T-P1.1
Option
Set
Part No.
4EU20G056
• All specifications are subject to change without notice.
004-02 / 20070523 / ea122_jbw.fm
(14/30)
JBW150W Type
SPECIFICATIONS AND STANDARDS
Part No.
Rated output voltage and current∗
Maximum output power
Input conditions
Input voltage Eac/Edc
Input frequency
Input current
Surge current
Leakage current
Power factor
Efficiency
W
V
Hz
A
A
mA
%
Output characteristics
Output voltage Edc
V
Voltage variable range Edc
V
Maximum output current
A
Overvoltage threshold Edc
V
Overcurrent threshold
A
Source effect
%
Load effect
%
Voltage
Temperature effect
%
stability
Drift(Time effect)
%
Recovery
%
Ripple Ep-p
mV
Ripple noise Ep-p
mV
Start up time
ms
Hold up time
ms
Auxiliary functions
Indicator display
Overvoltage protection
Overcurrent protection
Remote ON-OFF
Remote sensing
Standards
Safety standards
Noise terminal voltage
Input harmonics current requirement
CE marking
Constructions
External dimensions
mm
Weight
g
Mounting method
Case metal
∗
JBW05-30R
5V • 30A
150
JBW12-12R
12V • 12A
150
JBW15-10R
15V • 10A
150
85 to 265[Rating: 100-240]/120 to 370
47 to 66
2.7/1.5max.[100-240V]
30/60max.[100-240V]
0.75/0.75max.[AC.100V(DENAN)/240V(UL, IEC)]
0.99/0.95typ.[100-240V]
78/80typ.
81/83typ.
81/83typ.
[100-240V]
[100-240V]
[100-240V]
JBW24-6R3
24V • 6.3A
151.2
JBW48-3R2
48V • 3.2A
153.6
82/84typ.
[100-240V]
82/84typ.
[100-240V]
5
12
15
24
4.5 to 5.5
10.8 to 13.2
13.5 to 16.5
21.6 to 26.4
30
12.5
10
6.3(Peak7.5)
5.75 to 6.9
13.8 to 16.8
17.2 to 21
27.6 to 33.6
31.5min.
15.7min.
12.5min.
7.87min.
0.4max.[Within the input voltage range]
0.8max.[0 to 100% load]
1max.[Ambient temperature: –10 to +60°C]
0.4max.[25°C, input and output ratings, after input voltage ON for 30min to 8h]
±4max.[50 to 100% sudden load change]
80max.
120max.
120max.
120max.
120max.
150max.
150max.
150max.
500max.(400typ.)/500max.(300typ.)[AC.100/240V]
25/35typ.[AC.100/240V]
48
43.2 to 52.8
3.2
55.2 to 67.2
3.36min.
150max.
350max.
No
Voltage shut-down type(Latch).
Rectangular type, automatic recovery.
No
No
UL60950-1, CSA C22.2 No.60950-1(C-UL), EN60950-1(TÜV) approved.
FCC-B, VCCI-B, EN55011-B, EN55022-B meet.
EN61000-3-2
Meet.
40× 75× 222[H× W× L]
550max.
Can be attached to 1 side.
FR4
Current rating(maximum output current) is determined for –10 to +40°C. Derating is required when used outside this temperature range.
• All specifications are subject to change without notice.
004-02 / 20070523 / ea122_jbw.fm
(15/30)
JBW150W Type
SHAPES AND DIMENSIONS
222
37
(5)
212±0.5
5
(29.5)
CP3
1
UP
7
1
CP2
(4)
6
5
(4)
Input connector
(47.2)
75
3max.
1
3 CP1
65±0.5
1.6
(32.7)
(5)
5.0
9max.
9max.
(4)
Output voltage adjustment trimmer
Area for spacer(ø6max.)
Solder Side(3 Places)
(27.9)
Ground pattern area(ø6max.)
Solder Side(1 Place)
Dimensions in mm
±1mm : without specified dimensions
TERMINAL DESIGNATION
4
1
5
3
1
3
2 CP1
1
CP3 5
7
1
CP1
P1
L
P3
N
CP2 6
6
· Japan Solderless Terminal Co., Ltd.
VH Series B3P5-VH-B
Connector made by
Japan Solderless Terminal Co., Ltd.
Input Connector(CP1)VH Series
Output Connector(CP2)VH Series
Output Connector(CP3)VH Series
P1
P1
P2
P2
P3
P3
P4
7
P5
CP3
CP2
+
P5
P4
P5
P6
P6
P7
· Japan Solderless Terminal Co., Ltd.
VH Series B6P-VH-B
–
Terminal No.
1
2
3
4
5
6
7
Designations
Input terminal(L)
Input terminal(N)
Frame ground terminal(G)
Ground pad
–Output terminal(–)
+Output terminal(+)
Output voltage setting trim(+)
· Japan Solderless Terminal Co., Ltd.
VH Series B7P-VH-B
Power supply side
connector
Cable Side
Housing
Terminal
B3P5-VH-B
B6P-VH-B
B7P-VH-B
VHR-5N
VHR-6N
VHR-7N
SVH-21T-P1.1
SVH-21T-P1.1
SVH-21T-P1.1
Option
Set
Part No.
4EU00G062
• All specifications are subject to change without notice.
004-02 / 20070523 / ea122_jbw.fm
(16/30)
Characteristics, Functions, and Applications
BLOCK DIAGRAMS
JBW10W/15W/30W TYPES
Input
filter
circuit
L
AC input
N
Input
rectifier
circuit
Surge
current
limiting
circuit
Output rectifying
and
smoothing circuit
Input
smoothing
circuit
Overcurrent
detection
circuit
Power
switching
circuit
+
DC OUT
–
Overvoltage
protection
Drive
circuit
PWM
control circuit
Output voltage
control circuit
JBW50W TYPE
L
AC input
N
Surge
current
limiting
circuit
Input
filter
circuit
Input
smoothing
circuit
Output rectifying
and
smoothing circuit
Boost-up
circuit
PFC
control
circuit
Overcurrent
detection
circuit
+
DC OUT
–
Power
switching
circuit
Drive
circuit
Overvoltage
detection circuit
Control circuit
Output voltage
control circuit
COMMON SPECIFICATIONS
Temperature and humidity
Operating(°C)
Temperature range Operating available(°C)
Storage(°C)
Operating(%)RH
Humidity range
Storage(%)RH
Vibration and shock
5 to 10Hz
Vibration
10 to 200Hz
Acceleration
Shock
Pulse duration
Withstand voltage and insulation resistance
Input terminal to ground terminal(G)
Withstand voltage
Input terminal to output terminal
Output terminal to ground terminal(G)
Input terminal to ground terminal(G)
Insulation resistance Input terminal to output terminal
Output terminal to ground terminal(G)
–10 to +60
–20 to –10
–30 to +75
10 to 90[Maximum wet-bulb temperature: 35°C, without dewing]
All amplitude 10mm[3 directions, each 1h]
Acceleration 19.6m/s2 (2G)[3 directions, each 1h]
10 to 50W: 588m/s2 (60G)[3 directions, each 3 times]/75 to 150W: 588m/s2(60G)[Sine wave]
11±5ms
Eac: 2kV, 1min[Normal temperature, normal humidity, cutout current 10mA]
Eac: 3kV, 1min[Normal temperature, normal humidity, cutout current 10mA]
Eac: 500V, 1min[Normal temperature, normal humidity, cutout current 10mA]
Eac: 500V, 100MΩ min.[Normal temperature, normal humidity]
• All specifications are subject to change without notice.
004-02 / 20070523 / ea122_jbw.fm
(17/30)
Characteristics, Functions, and Applications
10 to 50W TYPES
OUTPUT POWER-AMBIENT TEMPERATURE(DERATINGS)
75 to 150W TYPES
OUTPUT POWER-AMBIENT TEMPERATURE(DERATINGS)
75, 100W TYPES
80
100
70
60
80
Output power(%)
Output power(%)
100
40
Available operating range
(outside of warranty)
20
(E),(F)
(C),(D)
(A)
60
40
Available operating range
(outside of warranty)
20
10 20 30 40 50
Ambient temperature(˚C)
60
71
0
–20 –10
INSTALLATIONS
• Mounting the power supply at the four corners with metal spacers (2 corners for 10W models).
• Maintain a min. 4mm clearance distance in order to satisfy insulation and high voltage safety requirements.
• Lay an insulating sheet under the power supply in case a min.
8mm installation space cannot be secured between the PC
board and the housing.
• Provide a min. 4mm distance between heat sink or component
surface and surrounding objects in order to cause a thermal convection.
• Since components are mounted on the back (solder) side of the
product, sufficient care should be taken when handling the
power supply to protect the PC board from shock, vibration, torsion, etc. which can result in damage caused by cracked chip
components.
;
;;
4mm
min.
Mounting screw dia.: 3mm
4mm
min.
+
+
8mm
min.
10
20
30
40
50
Ambient temperature(˚C)
100
60
50
40
Available operating range
(outside of warranty)
20
0
–20 –10
0
10
20
30
40
50
Ambient temperature(˚C)
60
INSTALLATION DIRECTION
(C)
(B)
(A) Standard installation
Heat sink
(E)
IN
Power
supply
60
(E),(F)
(C),(D)
(A)
80
(D)
4mm
min.
0
150W TYPE
Output power(%)
0
Components
–20 –10
(F)
OUT
UP
Housing
OUT
IN
Metal spacer
ø6mm max.
To install the power supply in a device, apply the standard installation direction (A) or (B).
In case of an installation in other directions, please contact TDK.
(A)
(B)
Component surface
Component surface
There are installation directions (B) to (F) as shown below in addition to the standard installation direction (A) for mounting the
power supply on an apparatus. The installation (B), however, is
inhibited because it will cause heat to be trapped inside the power
supply.
Derating of the output voltage and the ambient temperature for the
installation directions (C) to (F) are not the same as for the direction (A). Please consult us if you need.
The shaded portion indicates a side in which an output
connector is arranged.
• All specifications are subject to change without notice.
004-02 / 20070523 / ea122_jbw.fm
(18/30)
Characteristics, Functions, and Applications
RIPPLE NOISE MEASUREMENT CONDITIONS
Output connector
L
Load
+
C1
C2
Output ripple and noise measurement point (20MHz)
C1 : 100µF Electrolytic capacitor
C2 : 0.1µF Film capacitor
L : 150mm
SERIES OPERATION (TO INCREASE OUTPUT VOLTAGE OR
TO OBTAIN SEPARATE ±OUTPUT)
When the output voltage of a single power supply is insufficient,
several power supplies can be connected in series in order to
obtain a higher voltage or separate ±outputs.
If power supplies A and B in the illustration below are 5V each, a
10V output can be obtained in this connection. It should be noted
that, however, the output current is limited to the lower rated current value of the power supplies A and B. There is no problem if
the voltages of A and B are different from each other.
D1 and D2 in the illustration designate diodes for preventing
reverse voltage application. They are provided for preventing internal components of the power supply having the lower rated voltage
from being damaged by an applied reverse voltage caused by a
short circuit in the load or the like.
Use diodes which meet the following requirements:
Reverse withstanding voltage: Over twice that of the combined
output voltage
Forward current: Over twice that of the output current
Forward voltage drop: As small as possible
(e.g. Shottkey diode, etc.)
INSULATION AND WITHSTAND VOLTAGE TESTS
The insulation and withstand voltage tests may cause deterioration. Care must be taken for execution of the tests. The potential
must be equal among input, output, and FG (frame ground) terminals. It is preferable to use testers that gently start up at the testON and automatically discharge charged energy at the test-OFF.
Manual discharging after the tests should be through a resistor
around 100kΩ to 1MΩ (Do not perform discharging at low impedance. It may cause deterioration.)
In any case, take full countermeasures for electric-shock prevention.
OTHER CONDITIONS
• Unless conditions are otherwise specified in the specifications or
standards, 25°C and rated input-output should be applied.
SERIES CONNECTION FOR INCREASING OUTPUT VOLTAGE
Power supply A
+
–
D1
(A)∗
Power supply B
Load
+
–
D2
∗ For obtaining separate ±outputs, (A) should be zero voltage.
• All specifications are subject to change without notice.
004-02 / 20070523 / ea122_jbw.fm
(19/30)
Characteristics, Functions, and Applications
AC.200V TYPE: INPUT CURRENT
0.5
0.20
0.4
0.16
170V
0.12
240V
265V
0.3
85V
100V
0.2
132V
Input current(A)
Input current(A)
JBW10W TYPE TYPICAL CHARACTERISTICS: JBW05-2R0
AC.100V TYPE: INPUT CURRENT
0.1
0
0.04
0
20
40
60
Load(%)
80
40
60
Load(%)
80
80
Efficiency(%)
132V
100V
85V
60
40
20
100
170V
200V
265V
60
40
20
0
20
40
60
Load (%)
80
0
100
AC.100V TYPE: POWER FACTOR
1.0
1.0
0.8
0.8
85V
100V
132V
0.6
0
20
40
60
Load (%)
80
100
AC.200V TYPE: POWER FACTOR
0.4
Power factor
Power factor
20
100
80
0.6
170V
240V
265V
0.4
0.2
0.2
0.0
0
AC.200V TYPE: EFFICIENCY
100
Efficiency(%)
0
100
AC.100V TYPE: EFFICIENCY
0
0.08
0.0
0
20
40
60
Load (%)
80
100
AC.100V TYPE: SURGE CURRENT
0
20
40
60
Load (%)
80
100
AC.200V TYPE: SURGE CURRENT
Vin=100V
11A
Vin=240V
27.6A
H : 5ms/Div
V : 5A/Div
Enlarged view
H : 0.1ms/Div
V : 5A/Div
H : 5ms/Div
V : 10A/Div
Enlarged view
H : 0.1ms/Div
V : 10A/Div
• All specifications are subject to change without notice.
004-02 / 20070523 / ea122_jbw.fm
(20/30)
Characteristics, Functions, and Applications
JBW10W TYPE TYPICAL CHARACTERISTICS: JBW05-2R0
AC.100/200V TYPE: –20°C START UP CHARACTERISTICS
AC.100/200V TYPE: +60°C START UP CHARACTERISTICS
AC.265V
AC.265V
AC.85V
AC.85V
H : 50ms/Div
AC.100/200V TYPE: –20°C HOLD UP CHARACTERISTICS
H : 50ms/Div
AC.100/200V TYPE: +60°C HOLD UP CHARACTERISTICS
Off
Off
240V
170V
100V
100V
85V
85V
H : 10ms/Div
AC.100V/200V TYPE: –20°C OVERCURRENT CURVE
H : 10ms/Div
AC.100V/200V TYPE: +60°C OVERCURRENT CURVE
6
6
5
5
AC.85V
4
AC.132V
3
Output voltage(V)
Output voltage(V)
AC.85V
AC.170V
AC.265V
2
AC.265V
AC.170V
AC.132V
4
3
2
1
1
0
0
0
1
2
3
4
Load current(A)
5
6
0
1
2
3
4
Load current(A)
5
6
• All specifications are subject to change without notice.
004-02 / 20070523 / ea122_jbw.fm
(21/30)
Characteristics, Functions, and Applications
AC.200V TYPE: LIFE OF ELECTROLYTIC CAPACITOR
40
40
35
35
30
30
25
25
Life(Years)
Life(Years)
JBW10W TYPE TYPICAL CHARACTERISTICS: JBW05-2R0
AC.100V TYPE: LIFE OF ELECTROLYTIC CAPACITOR
20
15
20
15
10
30˚C
10
5
40˚C
50˚C
60˚C
70˚C
100
5
0
20
40
60
Load(%)
80
AC.100V TYPE: HOLD UP TIME
0
20
40
60
Load(%)
80
40˚C
50˚C
60˚C
70˚C
100
AC.200V TYPE: HOLD UP TIME
10000
1000
1000
100
115V
100V
85V
10
Hold up time(ms)
10000
Hold up time(ms)
30˚C
240V
200V
170V
100
10
1
1
10
25
50
Load(%)
75
100
10
25
50
Load(%)
75
100
CONDUCTIVE NOISE EMISSION
80
[PEAK DATA]
[dBµV]
70
60
VCCI-B(QP)
50
VCCI-B(AV)
(FCC-B)
40
30
20
10
0
0.15
0.5
5
1
10
30
Frequency(MHz)
• All specifications are subject to change without notice.
004-02 / 20070523 / ea122_jbw.fm
(22/30)
Characteristics, Functions, and Applications
JBW15W TYPE TYPICAL CHARACTERISTICS: JBW05-3R0
AC.100V TYPE: INPUT CURRENT
AC.200V TYPE: INPUT CURRENT
0.5
0.25
170V
85V
100V
0.3
132V
0.2
0.20
Input current(A)
Input current(A)
0.4
0.1
0
0
20
40
60
Load(%)
80
0
0
20
40
60
Load(%)
80
100
AC.200V TYPE: EFFICIENCY
100
80
80
132V
100V
85V
60
40
Efficiency(%)
Efficiency(%)
0.10
100
100
20
170V
240V
265V
60
40
20
0
20
40
60
Load (%)
80
0
100
AC.100V TYPE: POWER FACTOR
1.0
1.0
0.8
0.8
85V
100V
132V
0.6
0.4
0.2
0.0
0
20
40
60
Load (%)
80
100
AC.200V TYPE: POWER FACTOR
Power factor
Power factor
0.15
0.05
AC.100V TYPE: EFFICIENCY
0
240V
265V
0.6
170V
240V
265V
0.4
0.2
0
20
40
60
Load (%)
80
0.0
100
AC.100V TYPE: SURGE CURRENT
0
20
40
60
Load (%)
80
100
AC.200V TYPE: SURGE CURRENT
Vin=100V
Vin=240V
30A
12.1A
H : 5ms/Div
V : 5A/Div
Enlarged view
H : 0.5ms/Div
V : 5A/Div
H : 5ms/Div
V : 10A/Div
Enlarged view
H : 0.5ms/Div
V : 10A/Div
• All specifications are subject to change without notice.
004-02 / 20070523 / ea122_jbw.fm
(23/30)
Characteristics, Functions, and Applications
JBW15W TYPE TYPICAL CHARACTERISTICS: JBW05-3R0
AC.100/200V TYPE: –20°C START UP CHARACTERISTICS
AC.100/200V TYPE: +60°C START UP CHARACTERISTICS
AC.265V
AC.265V
AC.85V
AC.85V
H : 10ms/Div
AC.100/200V TYPE: –20°C HOLD UP CHARACTERISTICS
H : 10ms/Div
AC.100/200V TYPE: +60°C HOLD UP CHARACTERISTICS
Off
Off
240V
240V
100V
100V
H : 50ms/Div
H : 50ms/Div
85V
85V
H : 10ms/Div
H : 10ms/Div
H : 10ms/Div
H : 10ms/Div
AC.100V/200V TYPE: +60°C OVERCURRENT CURVE
7
7
6
6
5
Output voltage(V)
Output voltage(V)
AC.100V/200V TYPE: –20°C OVERCURRENT CURVE
AC.85V
4
AC.240V
AC.265V
3
2
AC.85V
4
AC.265V
3
AC.240V
2
AC.100V
1
0
AC.100V
5
1
0
1
2
3
Load current(A)
4
5
0
0
1
2
3
Load current(A)
4
5
• All specifications are subject to change without notice.
004-02 / 20070523 / ea122_jbw.fm
(24/30)
Characteristics, Functions, and Applications
AC.200V TYPE: LIFE OF ELECTROLYTIC CAPACITOR
40
16
35
14
30
12
25
10
Life(Years)
Life(Years)
JBW15W TYPE TYPICAL CHARACTERISTICS: JBW05-3R0
AC.100V TYPE: LIFE OF ELECTROLYTIC CAPACITOR
20
15
10
30˚C
40˚C
50˚C
60˚C
70˚C
100
5
0
20
40
60
Load(%)
80
8
4
40˚C
2
50˚C
60˚C
70˚C
100
0
20
AC.100V TYPE: HOLD UP TIME
40
60
Load(%)
80
AC.200V TYPE: HOLD UP TIME
10000
1000
1000
Hold up time(ms)
10000
Hold up time(ms)
30˚C
6
100
115V
100V
10
240V
200V
170V
100
10
85V
1
10
25
50
Load(%)
75
1
100
10
25
50
Load(%)
75
100
CONDUCTIVE NOISE EMISSION
[dBµV]
[PEAK DATA]
100
90
80
70
60
VCCI(QP)
50
VCCI(AV)
FCC-B
40
30
20
10
0
–10
0.15
0.5
1
5
10
20
30
Frequency [MHz]
• All specifications are subject to change without notice.
004-02 / 20070523 / ea122_jbw.fm
(25/30)
Characteristics, Functions, and Applications
JBW30W TYPE TYPICAL CHARACTERISTICS: JBW05-6R0
AC.100V TYPE: INPUT CURRENT
AC.200V TYPE: INPUT CURRENT
1.0
0.5
170V
0.4
85V
100V
0.6
132V
0.4
Input current(A)
Input current(A)
0.8
0.2
0
0
20
40
60
Load(%)
80
20
40
60
Load(%)
80
100
100
132V
100V
85V
40
170V
240V
265V
80
Efficiency(%)
60
60
40
20
20
0
20
40
60
Load (%)
80
0
100
AC.100V TYPE: POWER FACTOR
0.8
0.8
85V
100V
132V
0.4
Power factor
1.0
0.6
0
20
40
60
Load (%)
80
100
AC.200V TYPE: POWER FACTOR
1.0
0.6
170V
240V
265V
0.4
0.2
0.2
0.0
0
AC.200V TYPE: EFFICIENCY
80
Efficiency(%)
0
100
100
Power factor
0.2
0.1
AC.100V TYPE: EFFICIENCY
0
240V
265V
0.3
0
20
40
60
Load (%)
80
0.0
100
AC.100V TYPE: SURGE CURRENT
0
20
40
60
Load (%)
80
100
AC.200V TYPE: SURGE CURRENT
Vin=100V
Vin=240V
31.2A
12.8A
H : 5ms/Div
V : 5A/Div
H : 5ms/Div
V : 10A/Div
• All specifications are subject to change without notice.
004-02 / 20070523 / ea122_jbw.fm
(26/30)
Characteristics, Functions, and Applications
JBW30W TYPE TYPICAL CHARACTERISTICS: JBW05-6R0
AC.100/200V TYPE: –20°C START UP CHARACTERISTICS
AC.100/200V TYPE: +60°C START UP CHARACTERISTICS
AC.265V
AC.265V
AC.85V
AC.85V
H : 50ms/Div
H : 50ms/Div
AC.100/200V TYPE: –20°C HOLD UP CHARACTERISTICS
AC.100/200V TYPE: +60°C HOLD UP CHARACTERISTICS
Off
Off
170V
170V
100V
100V
85V
85V
H : 10ms/Div
H : 10ms/Div
AC.100V/200V TYPE: –20°C OVERCURRENT CURVE
AC.100V/200V TYPE: +60°C OVERCURRENT CURVE
7
7
6
AC.132V
Output voltage(V)
Output voltage(V)
6
5
AC.170V
4
3
AC.265V
2
5
AC.170V
4
3
AC.265V
2
AC.85V
AC.85V
1
0
AC.132V
1
0
2
4
6
Load current(A)
8
10
0
0
2
4
6
Load current(A)
8
10
• All specifications are subject to change without notice.
004-02 / 20070523 / ea122_jbw.fm
(27/30)
Characteristics, Functions, and Applications
AC.200V TYPE: LIFE OF ELECTROLYTIC CAPACITOR
16
8
14
7
12
6
10
5
Life(Years)
Life(Years)
JBW30W TYPE TYPICAL CHARACTERISTICS: JBW05-6R0
AC.100V TYPE: LIFE OF ELECTROLYTIC CAPACITOR
8
6
4
30˚C
2
40˚C
50˚C
60˚C
70˚C
100
0
20
40
60
Load(%)
80
4
2
0
20
1000
Hold up time(ms)
1000
Hold up time(ms)
10000
100
115V
100V
85V
10
60
Load(%)
80
75
240V
200V
170V
100
10
1
50
Load(%)
40
50˚C
60˚C
70˚C
100
AC.200V TYPE: HOLD UP TIME
10000
25
40˚C
1
AC.100V TYPE: HOLD UP TIME
10
30˚C
3
1
100
10
25
50
Load(%)
75
100
CONDUCTIVE NOISE EMISSION
[dBµV]
[PEAK DATA]
80
70
60
VCCI(QP)
50
VCCI(AV)
FCC-B
40
30
20
10
0
–10
0.15
0.5
1
5
10
20
30
Frequency [MHz]
• All specifications are subject to change without notice.
004-02 / 20070523 / ea122_jbw.fm
(28/30)
Characteristics, Functions, and Applications
JBW50W TYPE TYPICAL CHARACTERISTICS: JBW05-10R
AC.100V TYPE: INPUT CURRENT
AC.200V TYPE: INPUT CURRENT
0.5
1.0
0.4
85V
100V
0.6
132V
0.4
Input current(A)
Input current(A)
0.8
0.2
0.3
0.1
0
20
40
60
Load(%)
80
0
20
40
60
Load(%)
80
100
AC.200V TYPE: EFFICIENCY
100
100
132V
100V
85V
60
40
265V
240V
170V
80
Efficiency(%)
80
Efficiency(%)
0
100
AC.100V TYPE: EFFICIENCY
60
40
20
20
0
0
20
40
60
Load (%)
80
100
0
AC.100V TYPE: POWER FACTOR
20
40
60
Load (%)
80
100
AC.200V TYPE: POWER FACTOR
85V
100V
132V
1.0
170V
240V
265V
1.0
0.8
Power factor
0.8
Power factor
240V
265V
0.2
0
0
170V
0.6
0.4
0.6
0.4
0.2
0.2
0.0
0.0
0
20
40
60
Load (%)
80
0
100
AC.100V TYPE: SURGE CURRENT
20
40
60
Load (%)
80
100
AC.200V TYPE: SURGE CURRENT
Vin=100V
16.2A
Vin=240V
43A
H : 5ms/Div
V : 10A/Div
H : 5ms/Div
V : 20A/Div
Enlarged view
Enlarged view
H : 0.2ms/Div
V : 10A/Div
H : 0.2ms/Div
V : 20A/Div
• All specifications are subject to change without notice.
004-02 / 20070523 / ea122_jbw.fm
(29/30)
Characteristics, Functions, and Applications
JBW50W TYPE TYPICAL CHARACTERISTICS: JBW05-10R
AC.100/200V TYPE: –20°C START UP CHARACTERISTICS
AC.100/200V TYPE: +60°C START UP CHARACTERISTICS
AC.265V
AC.265V
AC.85V
AC.85V
H : 50ms/Div
H : 50ms/Div
AC.100/200V TYPE: –20°C HOLD UP CHARACTERISTICS
AC.100/200V TYPE: +60°C HOLD UP CHARACTERISTICS
Off
Off
AC.170V
AC.170V
AC.100V
AC.100V
AC.85V
AC.85V
H : 10ms/Div
AC.100V/200V TYPE: +60°C OVERCURRENT CURVE
7
7
6
6
Output voltage(V)
Output voltage(V)
AC.100V/200V TYPE: –20°C OVERCURRENT CURVE
H : 10ms/Div
5
4
3
5
4
3
2
2
AC.100V
AC.100V
1
1
AC.240V
AC.240V
0
0
0
4
8
12
Load current(A)
16
20
0
4
8
12
Load current(A)
16
20
• All specifications are subject to change without notice.
004-02 / 20070523 / ea122_jbw.fm
(30/30)
Characteristics, Functions, and Applications
AC.200V TYPE: LIFE OF ELECTROLYTIC CAPACITOR
8
8
7
7
6
6
5
5
Life(Years)
Life(Years)
JBW50W TYPE TYPICAL CHARACTERISTICS: JBW05-10R
AC.100V TYPE: LIFE OF ELECTROLYTIC CAPACITOR
4
3
30˚C
4
3
30˚C
40˚C
1
50˚C
1
60˚C
50˚C
60˚C
0
0
20
40
60
Load(%)
80
20
100
AC.100V TYPE: HOLD UP TIME
40
60
Load(%)
80
100
AC.200V TYPE: HOLD UP TIME
1000
Hold up time(ms)
1000
Hold up time(ms)
40˚C
2
2
100
115V
100V
85V
10
1
10
25
50
Load(%)
75
100
240V
200V
170V
10
1
100
10
25
50
Load(%)
75
100
CONDUCTIVE NOISE EMISSION
[dBµV]
[PEAK DATA]
90
80
70
60
VCCI(QP)
50
VCCI(AV)
FCC-B
40
30
20
10
0
0.15
0.5
1
5
10
20
30
Frequency [MHz]
• All specifications are subject to change without notice.
004-02 / 20070523 / ea122_jbw.fm