Download Sanyo ML414 User's Manual

Transcript
Cell Type ML414
Specifications
Nominal Capacity*1
Nominal Voltage
Standard Charge/Discharge Current
Max. Discharge Current
Charge/Discharge Cycle Characteristics
Charging Method
Temperature Range
Weight
D
H
Dimensions
1.0mAh
3V
0.005mA
0.2mA
Continuous *2
0.6mA
Pulse*3
Discharging Depth of 5%
3000
Discharging Depth of 20%
300
Constant Voltage Charge
3.1±0.15V
Hight Temperature
2.95±0.15V
-20℃~60℃
0.07g
Diameter(D)
4.8mm
Height(H)
1.4mm
*1 Nominal capacity is determined to an end voltage of 2.0V when the battery is allowed to
discharge at a standard current level at 23oC.
*2 Current value is determined so that 50% of the nominal capacity is obtained with an end
voltage of 2.0V at 23 oC.
*3 Current value for obtaining 2.0V cell voltage when 15sec. pulse is applied
at 50% discharge depth at 23 oC.
Typical Characteristics
Charging Voltage vs. Capacity of ML414
Temperature Characteristics of ML414
3.5
3.0
0.5
Cell Voltage(V)
Discharge Capacity(mAh)
Charging Voltage : 3.0V
Load : 300kohm
1.0
Charging Conditon(discharged cell to 2.0V)
Load:3kohm
Temp.: 23 oC
Charging Duration : 30hours
Discharging condition
Load : 300kohm
Temp.: 23 oC
End Voltage : 2.0V
2.0
-20 o C
23 o C
60 o C
1.5
1.0
0
2.6
2.8
3.0
0
3.2
Charging Voltage(V)
3.5
Discharge Condition
Load : 300kohm
Temp.: 23 oC
3.0
2.5
2.0
after 20days storage at 60 oC
1.5
1.0
0
50
100
Duration(hour)
150
50
100
Duration(hour)
Discharge Characteristics after Storage of ML414
Cell Voltage(V)
2.5
200
150
200