Calculite® HID Wall Wash Page 1 of 2 C7E17OW 7” Aperture, ED17 (Open Rated) Ceramic Metal Halide 8 6 2 1 4 5 3 8 9 7 10-7/8" (276 mm) 18-5/8" (473 mm) 10-1/2" (267 mm) 20" (508 mm) to 30" (762 mm) 8-1/4" 9-3/4" (210 mm) (248 mm) Top View (Magnetic Ballast) 9-7/8" (251 mm) Vertical Adjustment: 5/8" (16 mm) to 2 7/8" (73 mm) 10-7/8" (276 mm) 20" (508 mm) to 30" (762 mm) 9-3/4" (248 mm) 11" (280 mm) (100/150W) Top View (Electronic Ballast) 2" (50 mm) max. Ceiling Thickness 7-1/8" (181 mm) Dia. 8-5/8" (200 mm) Dia. Ceiling Cutout: 8” (203mm) Dia. Reflector Trim C7E17OW CLW CLP CCDW CCDP CCZW CCZP Specular Clear, White Painted Flange. Specular Clear, Matching Flange. Comfort Clear Diffuse, White Painted Flange. Comfort Clear Diffuse, Matching Flange. Champagne Bronze, White Painted Flange. Champagne Bronze, Matching Flange. Frame-In Kit Lamp (Coated, Ceramic MH) C770MHOE1 C710MHOE1 C715MHOE1 C770MHOU C710MHOU C715MHOU 70W E17, ED17, BD17 (Open Rated) 100W E17, ED17, BD17 (Open Rated) 150W E17, ED17, BD17 (Open Rated) 70W E17, ED17, BD17 (Open Rated) 100W E17, ED17, BD17 (Open Rated) 150W E17, ED17, BD17 (Open Rated) Features 1. Downlight/Wall Washer Reflector Trim: Anodized aluminum, 0.040” (16ga.). Provides vertical surface wall washing and medium beam downlighting; 50° visual cut-off to lamp and lamp image; self-flange in painted white or aperture-matching polished flange. Consult factory for other finishes. 2. Socket Housing: Galvanized steel, pre-wired with medium base pulse rated socket. Snaps onto upper reflector for secure attachment without tools; assures proper lamp alignment to optics for consistent performance. 3. Mounting Frame: 0.048" (18-ga.) galvanized steel includes pre-installed mounting bars. 4. Mounting Ring: 0.048" (18-ga.) galvanized steel. Designed for vertical adjustment from above or below for ceilings from 0" to 2" thick. Center-line notches allow consistent alignment of multiple fixtures. 5. Retention Springs: Rust resistant springs secure reflector in place for quick, tool-less installation. 6. Frame Vertical Adjustment Mechanism: Vertical adjustment mechanism accommodates mounting to virtually any ceiling system using pre-installed mounting bars, or 1/2" EMT tubing (by others). Single locking feature secures all adjustments. Alignment holes and markings allow fixture to be pre-set prior to installation. 7. Mounting Bars: 0.048" (18-ga.) Pre-installed, telescoping bars extend to 30" long and lock securely into position. Built-in locking tabs provide positive attachment to common T-bar systems. Self-centering feature simplifies installation in 24" O.C. grid systems. Attaches to steel or wood joists without accessories. 8. Ballast: Electronic 120V or 277V. Magnetic dual voltage (120V & 277V). Accessible from below for inspection and/or replacement without tools. 9. Junction Box: 0.059" (16-ga.) galvanized steel. UL listed for 8 No. 12 AWG, 90°C through branch circuit conductors; allows inspection from below. 10.Thermal Protector: (Not Shown) Meets NEC and UL requirements. Do not install insulation above nor within 3" (76mm) of any part of the luminaire. Electrical Electronic 120V / C770MHOE2 Electronic 277V Electronic 120V / C710MHOE2 Electronic 277V Electronic 120V / C715MHOE2 Electronic 277V Magnetic 120V/277V Magnetic 120V/277V Magnetic 120V/277V Electrical (cont) Ballast 70W MH 100W MH 150W MH ANSI Code M98/M143 M90/M140 M102 Voltage 120/277 120/277 120/277 Max. Amps 0.67/0.28 0.90/0.43 1.40/0.61 Input Watts 78 110 167 Magnetic Ballast: 120V/277V dual voltage, 60 Hz., encased and potted, HX-HPF circuit type, high power factor, sound rating “B”, -20°F minimum starting temperature, Type 1 Outdoor rating. Ballast ANSI Code Voltage Max. Amps Input Watts 70W MH M98/M143 120/277 1.90/0.80 94 100W MH M90/M140 120/277 2.40/1.10 125 150W MH M102 120/277 3.70/1.60 180 Options and Accessories Fuse: Add suffix F1 or F2 to Frame-In Kit (F1=120V, F2=277V) Chicago Plenum: Consult Factory. Labels UL (Suitable for Damp Locations), I.B.E.W. For 150W, install fixtures with minimum spacing between: 1. Center-to-center of adjacent luminaries: 3 feet. 2. Top of luminaire to overhead building member: 3 inch. 3. Luminaire center to side building member: 1 1/2 feet. Job Information Type: Job Name: Cat. No.: Lamp(s): Notes: Electronic Ballast: 120V or 277V, 50/60 Hz., encased, high-power factor, T.H.D. <15%, thermally and transient protected, RMI / RFI complies with FCC Part 18 non-consumer equipment, shut-down circuit at end of lamp life, sound rating "A", -5°F (-20°F for 150W) minimum starting temperature, Type 1 outdoor rating. Lightolier a Genlyte company www.lightolier.com 631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2004 Genlyte Group LLC • B1004 Calculite® HID Wall Wash Page 2 of 2 C7E17OW 7” Aperture, ED17 (Open Rated) Ceramic Metal Halide 3' 4' 6' Lighting Data - Example C7E170W illumination on the wall 6' down from the ceiling is 28.0 f.c. beneath and 27.7 f.c. between fixtures. CANDLEPOWER DISTRIBUTION 28.0 f.c. 28.0 f.c. 27.7 f.c. Wall Wash Side Downlight Side 1 2 3 4 5 6 7 8 9 10 11 12 13 14 40.8 53.2 50.4 45.3 42.4 38.1 33.9 30.2 27.2 24.5 22.2 20.5 19.2 18.4 35.4 49.6 50.7 46.2 42.9 39.1 34.7 30.5 27.1 24.3 22.0 20.3 19.1 18.4 40.8 53.2 50.3 45.3 42.4 38.1 33.9 30.2 27.2 24.5 22.2 20.5 19.2 18.4 1 2 3 4 5 6 7 8 9 10 11 12 13 14 34.7 43.5 40.3 34.5 31.4 28.0 24.3 21.4 19.1 17.3 15.8 14.6 13.8 13.2 19.9 31.3 32.2 32.0 30.2 27.7 25.2 22.4 19.8 17.6 15.9 14.5 13.6 13.0 34.7 43.4 40.3 34.5 31.4 28.0 24.2 21.4 19.1 17.3 15.8 14.6 13.7 13.2 Distance From Ceiling in Feet 30° 3,500 Distance From Ceiling in Feet 1,705 Distance From Ceiling in Feet 70W ED17 PHILIPS COATED CERAMIC MH, 3K. LUMEN RATING = 5700 LMS., AROMAT ELECTRONIC BALLAST, CL FINISH REFLECTOR TRIM, REPORT NO. 2343FR Multiple Units Multiple Units Multiple Units Footcandles On Wall Footcandles On Wall Footcandles On Wall 3' from Wall - 3' On Center 3' from Wall - 4' On Center 4' from Wall - 4' On Center 60° 3' 4' 4' 1 2 3 4 5 6 7 8 9 10 11 12 13 14 19.2 26.9 30.9 28.7 26.2 25.1 23.9 22.2 20.6 19.0 17.7 16.5 15.5 14.6 16.5 25.9 29.0 29.2 27.1 25.3 24.3 22.8 21.1 19.3 17.8 16.4 15.3 14.5 19.2 26.9 30.9 28.7 26.2 25.1 23.9 22.2 20.5 19.0 17.7 16.5 15.4 14.6 5,500 Downlight Side Wall Wash Side 46.6 60.9 58.6 51.9 49.3 42.6 36.0 31.6 28.4 25.8 23.6 21.7 20.4 19.6 28.6 43.0 44.3 44.8 42.1 39.5 36.4 32.5 28.7 25.6 23.2 21.3 20.1 19.3 46.6 60.9 58.6 51.9 49.3 42.6 36.0 31.6 28.4 25.8 23.6 21.7 20.4 19.6 1 2 3 4 5 6 7 8 9 10 11 12 13 14 25.8 37.5 43.4 41.4 38.9 38.4 36.5 33.5 30.7 28.3 26.2 24.4 22.8 21.6 22.6 35.2 39.7 39.8 37.1 34.9 33.9 32.3 30.0 27.7 25.6 23.8 22.4 21.2 25.8 37.5 43.4 41.4 38.9 38.4 36.5 33.5 30.7 28.3 26.2 24.4 22.8 21.6 Distance From Ceiling in Feet 30° 4,125 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Distance From Ceiling in Feet 2,750 Distance From Ceiling in Feet 100W ED17 PHILIPS COATED CERAMIC MH, 3K. LUMEN RATING = 8500 LMS., AROMAT ELECTRONIC BALLAST, CL FINISH REFLECTOR TRIM, REPORT NO. 2344FR Multiple Units Multiple Units Multiple Units Footcandles On Wall Footcandles On Wall Footcandles On Wall 3' from Wall 4' On Center 4' from Wall - 5' On Center 4' from Wall - 4' On Center 1,375 60° 4' 4' 5' 1 2 3 4 5 6 7 8 9 10 11 12 13 14 24.0 33.5 38.4 36.5 33.3 32.5 31.2 28.1 25.3 23.2 21.7 20.4 19.3 18.4 16.7 26.5 30.1 30.3 30.1 28.8 27.6 26.6 25.3 23.5 21.8 20.2 18.9 17.9 24.0 33.5 38.3 36.5 33.3 32.5 31.1 28.1 25.3 23.2 21.7 20.4 19.3 18.4 8,500 Downlight Side Wall Wash Side 47.4 68.3 74.4 71.4 71.3 63.3 55.4 49.6 44.9 40.6 37.0 33.9 31.8 30.5 38.1 57.9 64.1 69.7 68.2 65.2 59.4 52.4 45.9 40.5 36.5 33.4 31.3 30.1 47.4 68.3 74.4 71.4 71.3 63.3 55.3 49.6 44.9 40.6 37.0 33.9 31.7 30.5 1 2 3 4 5 6 7 8 9 10 11 12 13 14 30.7 44.7 52.7 54.6 54.9 55.6 53.7 50.5 47.3 44.2 41.2 38.3 35.9 34.0 28.7 41.6 50.5 55.5 56.5 56.9 56.6 53.2 48.8 44.7 41.1 38.1 35.8 34.0 30.7 44.6 52.7 54.6 54.9 55.6 53.7 50.5 47.3 44.2 41.2 38.3 35.8 34.0 Job Information Lighting data above is certified, computed by LSI Program **TEST-LITE** Distance From Ceiling in Feet 30° 6,375 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Distance From Ceiling in Feet 2,750 Distance From Ceiling in Feet 150W ED17 PHILIPS COATED CERAMIC MH, 3K. LUMEN RATING = 11900 LMS., AROMAT ELECTRONIC BALLAST, CL FINISH REFLECTOR TRIM, REPORT NO. 2365FR Multiple Units Multiple Units Multiple Units Footcandles On Wall Footcandles On Wall Footcandles On Wall 3' from Wall 4' On Center 4' from Wall - 5' On Center 4' from Wall - 4' On Center 3,125 60° 4' 4' 5' 1 2 3 4 5 6 7 8 9 10 11 12 13 14 26.8 38.3 44.7 47.1 45.7 46.5 45.3 41.7 38.5 36.0 34.0 32.0 30.2 28.9 23.7 33.5 40.3 43.1 45.8 45.6 45.2 43.7 41.0 37.9 34.8 32.1 29.9 28.3 26.8 38.3 44.7 47.1 45.7 46.5 45.3 41.7 38.5 36.0 34.0 32.0 30.2 28.9 Type: Lightolier a Genlyte company www.lightolier.com 631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2004 Genlyte Group LLC • B1004