Calculite® Evolution Recessed Downlight
Page 1 of 1
C4A120
4 1/2” Aperture Incandescent 120V Non-IC AirSeal® Frame-In Kit
9 1/2" Dia.
7
6
5
2
3
1
13 3/4" to 24"
Adjustment
(mounting bars included)
4
7 3/4" min.*
8 1/4" max.
7"
1 1/4" Max. Ceiling Thk.
*7 3/4" min. is for
up to 3/4" thick ceiling.
7 3/4"
12 3/8"
14 3/8" O.A.
Ceiling Cutout: 5 1/16” (129 mm) Dia.
Frame-In Kit
Reflector Trim
C4A120
Open
Downlight
Open
Downlight
Adjustable
Accent
Open
Wall Washer/Downlight
Lensed
Wall Washer
C4AD
100W A19, MB19
100W BT15
C4P20D
50W PAR20
75W PAR16
75W BR19, R20
C4P20A
50W PAR20
75W PAR16
C4AW
100W A19, MB19
100W BT15
C4P20L
50W PAR20
75W PAR16
Features
Options and Accessories
1. Housing: Steel, 0.03" (22 ga.). Top Cover: Aluminum, 0.04" (14 ga.). Matte
black finish. AirSeal® housing minimizes air leakage to less than 2CFM at
1.57 PSF (or 75pa).
2. Mounting Frame: Die-cast aluminum for dry or plaster ceilings. Locks into
position along length of mounting bars with locking screws.
3. Retaining Springs: Precision-tooled steel springs secure reflector trim to
mounting frame for quick, tool-less installation.
4. Mounting Bars: Galvanized steel, 0.06" (16 ga.). Bars pivot for easy installation and wire in below ceiling line. Bars extend to accommodate 16" to 24"
O.C. joist spacing. Bars can accommodate 12" O.C. joist spacing after a slight
field modification (see instruction sheet). Integral self-tapping screws for
securing to wood or metal construction. Built-in tabs for locking to T-bars
without the need of accessories.
5. Snap-In Connectors: Keyed to accept power and socket harnesses which
are provided with reflector trim.
6. Junction Box: Galvanized steel .063" (14 ga.). UL Listed for maximum of 8
No. 12 AWG 90°C through branch circuit conductors. Accessible from inside
and outside of fixture. Outside J-Box door is hinged for maximum opening.
Snap-in plug is provided on inside cover for quick connection to power harness.
7. Thermal Protector: Meets NEC and UL requirements. Insulation must be
kept 3" away from fixture sides and wiring compartments and must not be
placed above fixture in a manner which will entrap heat.
8. Reflector Trim: Compatible reflector trims are listed above. See separate
reflector trim specification sheets for complete catalog numbers and details.
Chicago Plenum:
Add LC to frame suffix.
Label
UL Listed (Suitable for damp locations), I.B.E.W.
Air leakage is less than 2CFM at 75pa, tested in accordance with ASTM E-283.
US Patent 5,957,573. Other US and Foreign Patents Pending.
Job Information
Type:
Job Name:
Cat. No.:
Lamp(s):
Notes:
Lightolier a Genlyte Thomas Company
www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2002 Genlyte Thomas Group LLC (Lightolier Division) • A0902