Download Fedders C10 User's Manual
Transcript
Residential & Light Commercial HVAC C10 High Efficiency Series 10 SEER Remote Condensing Units PERFORMANCE: Efficiency rating of 10.0 SEER Cooling capacities from 11⁄2 to 5 tons Rated in accordance with D.O.E. test standards FEATURES: Quiet, top air discharge G-90 galvanized steel exterior cabinet with 1000-hour salt spray, powder-coated finish Long-life copper tubes, aluminum fin refrigerant coils State-of-the-art compressors Powder-coated fan guard Full louvered panel to protect coil Large wrap-around coil surface Control box located for easy access to electrical controls Formed base with 21⁄2” ground clearance Factory-installed liquid line filter dryer WARRANTY: Limited 10-year warranty on compressor Limited 5-year warranty on all parts C10 High Efficiency Series MODEL SPECIFICATIONS MODEL NUMBER C1018BBD1VF C1024BBD1VF C1030BBD1VF C1036BBD1VF C1036BBD3VF PERFORMANCE DATA NOMINAL COOLING BTU/H 18 000 22 400 28 600 34 000 SEER BTU/H-W 10.0 10.0 10.0 10.0 CFM 600 800 1000 1200 VOLTS/HZ/PHASE 208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/3 VOLTAGE RANGE 197-253 197-253 197-253 197-253 187-253 OPERATING CURRENT AMPS ➀ 9.8 10.8 11.4 17.0 12.7 MIN. WIRE AMPACITY 13.0 14.5 20.0 21.7 16.0 MAX. HACR BREAKER ➁ 20 20 30 30 25 COMPRESSOR DATA RLA 8.8 9.8 11.4 15.2 10.9 LRA 49 60 75 96 70 FAN DATA DIAMETER 18 INCH / 3 BLADE 18 INCH / 3 BLADE 18 INCH / 3 BLADE 18 INCH / 3 BLADE MOTOR TYPE PSC PSC PSC PSC HP (W) / FLA 1/6 / 1.0 1/6 / 1.0 1/6 / 1.0 1/6 / 1.0 RPM 1075 1075 1075 1075 CFM 1800 1800 1800 1800 OUTDOOR COIL TYPE ENHANCED ALUMINUM PLATE FIN / RIFLED COPPER TUBE FACE AREA 8.0 8.0 8.0 9.8 O.D. / F.P.I.-ROWS 5/16 / 18-1 5/16 / 22-1 3/8 / 22-1 3/8 / 18-1 REFRIGERANT LINE CONNECTIONS (SERVICE VALVE PORT I.D.) LIQUID 3/8 ID 3/8 ID 3/8 ID 3/8 ID VAPOR 3/4 ID 3/4 ID 3/4 ID 3/4 ID WEIGHTS NET WEIGHT — lbs. 119 119 128 139 SHIPPING WEIGHT — lbs. 125 125 134 146 C1036BBD4VF 460/60/3 415-508 5.9 15.0 15 4.7 33 1/4 / 1.2 COOLING PERFORMANCE DATA MATCHING EVAPORATOR COIL COOLING DATA AT EXTENDED OUTDOOR AMBIENTS °F.M.B.T.U.H. RATINGS AT STANDARD CONDITIONS OUTDOOR UNIT MODEL* EVAPORATOR COIL➂ BTUH SEER CFM C1018BBD E3009A 18 000 10 600 C1024BBD E3009A 22 400 10 800 C1030BBD E3618A 28 600 10 1000 C1036BBD E3618A 34 000 10 1200 C1042BBD E4824A 40 000 10 1300 C1048BBD E6026A 45000 10 1600 C1060CBD E6037A 56 000 10 1750 TOTAL SENSIBLE TOTAL SENSIBLE TOTAL SENSIBLE TOTAL SENSIBLE TOTAL SENSIBLE TOTAL SENSIBLE TOTAL SENSIBLE 80 85 90 95 100 105 110 115 20 200 14 500 25 500 18 300 31 300 22 500 36 400 26 200 43 000 31 000 49 700 35 800 58 800 42 300 19 700 14 200 24 700 17 800 30 500 22 000 36 000 25 900 42 000 30 200 48 500 34 900 57 900 41 700 19 100 13 750 23 800 17 100 29 800 21 500 35 500 25 600 41 000 29 500 47 300 34 000 56 900 41 000 18 000 13 000 22 400 16 100 28 600 19 300 34 000 24 500 40 000 28 800 46 000 33 100 56 000 40 300 17 600 12 700 22 200 15 900 28 000 20 200 32 400 23 300 38 500 27 700 44 400 32 000 54 000 38 900 16 800 12 100 21 500 15 500 27 000 19 400 30 700 22 100 37 000 26 600 43 000 31 000 52 000 37 400 15 900 11 400 20 700 14 900 26 000 18 700 29 100 20 900 35 500 25 560 41 500 29 900 50 000 36 000 15 000 10 800 19 900 14 330 25 000 18 000 27 500 19 800 34 000 24 500 39 800 28 600 48 000 34 600 *Basic model number only. See unit nomenclature on the last page for exact model number. FOOTNOTES: ➀ Amps at 104˚F OD temp. 80˚F DB / 67˚F WB indoor temp. ➁ Time delay type fuse for HACR Circuit Breaker. ➂ For indoor coils nomenclature see indoor coil specification sheet. ➃ Air Handler includes Evaporator Coil. MODEL SPECIFICATIONS MODEL NUMBER C1042BBD1VF C1048BBD1VF C1048BBD3VF C1048BBD4VF C1060CBD1VF C1060CBD3VF C1060CBD4VF PERFORMANCE DATA NOMINAL COOLING BTU/H 40 000 45 000 56 000 SEER BTU/H-W 10.0 10.0 10.0 CFM 1300 1600 1750 VOLTS/HZ/PHASE 208-230/60/1 208-230/60/1 208-230/60/3 460/60/3 208-230/60/1 208-230/60/3 VOLTAGE RANGE 197-253 197-253 187-253 415-508 197-253 187-253 OPERATING CURRENT AMPS ➀ 20.7 26.7 16.6 8.7 29.2 18.8 MIN. WIRE AMPACITY 26.4 31.8 19.3 11.0 36.0 23.0 MAX. HACR BREAKER ➁ 35 50 30 15 60 35 COMPRESSOR DATA RLA 18.5 24.5 14.8 7.5 27.0 16.6 LRA 103 137 91 46 150 124 FAN DATA DIAMETER 18 INCH / 4 BLADE 18 INCH / 4 BLADE 22 INCH / 3 BLADE MOTOR TYPE PSC PSC PSC HP (W) / FLA 1/5 / 1.8 1/5 / 1.8 1/4 / 1.2 1/4 / 2.2 RPM 1075 1075 1075 CFM 2 400 2 400 3 400 OUTDOOR COIL TYPE ENHANCED ALUMINUM PLATE FIN / RIFLED COPPER TUBE FACE AREA 12.0 12.0 18.3 O.D. / F.P.I.-ROWS 3/8 / 18-1 3/8 / 22-1 3/8 / 18-1 REFRIGERANT LINE CONNECTIONS (SERVICE PORT I.D.) LIQUID 3/8 ID 3/8 ID 3/8 ID VAPOR 3/4 ID 7/8 ID 7/8 ID WEIGHTS NET WEIGHT — lbs. 148 150 201 SHIPPING WEIGHT — lbs. 156 158 210 460/60/3 415-508 9.1 12.0 15 7.9 59 1/4 / 1.2 COOLING PERFORMANCE DATA MATCHING AIR HANDLER COOLING DATA AT EXTENDED OUTDOOR AMBIENTS °F.M.B.T.U.H. RATINGS AT STANDARD CONDITIONS OUTDOOR UNIT MODEL* AIR HANDLER➃ BTUH SEER CFM C1018BBD1 A24B1 18 000 10 600 C1024BBD1 A24B1 22 400 10 800 C1030BBD1 A36B1 28 600 10 1000 C1036BBD1 A36B1 34 000 10 1200 C1042BBD1 A42B1 40 000 10 1300 C1048BBD1 A48B2 45 000 10 1600 C1060CBD1 A60B1 56 000 10 1750 TOTAL SENSIBLE TOTAL SENSIBLE TOTAL SENSIBLE TOTAL SENSIBLE TOTAL SENSIBLE TOTAL SENSIBLE TOTAL SENSIBLE 80 85 90 95 100 105 110 115 20 200 14 500 25 500 18 150 31 300 21 900 36 400 26 300 43 000 31 400 49 700 34 950 58 800 41 400 19 700 14 100 24 700 17 600 30 500 22 700 36 000 25 900 42 000 30 850 48 500 57 900 57 900 41 000 19 100 13 700 23 800 17 150 29 800 22 150 35 500 26 450 41 000 30 000 47 300 33 600 56 900 40 550 18 000 12 900 22 400 16 700 28 600 21 450 34 000 25 600 40 000 29 400 46 000 32 400 56 000 40 300 17 600 12 700 22 200 16 000 28 000 21 100 32 400 24 450 38 500 28 000 44 400 31 850 54 000 39 000 16 800 12 150 21 500 15 550 27 000 20 400 30 700 23 250 37 000 26 900 43 000 31 100 52 000 37 600 15 900 11 500 20 700 15 000 26 000 19 650 29 100 22 100 35 500 25 600 41 500 30 700 50 000 36 400 15 000 10 900 19 900 14 350 25 000 18 750 27 500 20 650 34 000 24 550 39 800 29 000 48 000 35 050 Residential & Light Commercial – 10 SEER Remote Condensing Units CONDENSER DIMENSIONS (INCHES) MODEL C1018BVF C1024BVF C1030BVF C1036BVF C1042BVF C1048BVF C1060CVF C A UNIT B C A SHIPPING B 211/2 211/2 221/2 231/2 231/2 211/2 211/2 211/2 211/2 211/2 291/2 211/2 211/2 211/2 211/2 211/2 291/2 221/2 221/2 261/2 321/2 321/2 321/2 231/2 231/2 231/2 231/2 231/2 311/2 231/2 231/2 231/2 231/2 231/2 311/2 MODEL KEY: Residential & Light Commercial – Outdoor Unit UNIT EFFICIENCY C 23 23 23 27 33 33 33 B A REMOTE CONDENSER AIR CONDITIONER C 10 NOMINAL CAPACITY CHASSIS MODEL VERSION 24 B B OPTION LEVEL D = STANDARD UNIT R-22 E = STANDARD UNIT R-407 F = HIGH & LOW PRESSURE SWITCH MODEL KEY: Air Handler D X– V X A V = VALVE SWEAT TYPE FITTING 1 = 230/208 VOLT, 1 PHASE, 60 Hz 2 = 220/240 VOLT, 1 PHASE, 50 Hz 3 = 230/208 VOLT, 3 PHASE, 60 Hz 4 = 460 VOLT, 3 PHASE, 60 Hz 5 = 230 VOLT, 3 PHASE, 50 Hz 6 = 380 VOLT, 3 PHASE, 50 Hz 24 B CE IFIED TO A RI C O IT UN TIO MPLYING DI A N R AIR Y CO U MAN FACTU RT NING A E TI FI T IO F UIPMEN • R Q C S TA T I O N S E C T D ANDAR O C I NS 2 0 • E R EVAPORATOR DESIGNATION S R 1 A RE NOMINAL BTU/H R Fedders Unitary Products 505 Martinsville Rd. Liberty Corner, NJ 07938 (908) 604-8686 Form No. F-C10-0804 MODEL REVISION MODEL SERIES BRAND 1 Rated in Accordance with ARI Standard 210/240. Certification Applies Only When Used with Proper Components as Listed with ARI. All product specifications reflect available information at the printing of this brochure. Fedders reserves the right to revise or modify products and/or specifications without notice. ©2004 Fedders Unitary Products. Fedders is a registered trademark of Fedders North America, Inc.