Download Delta Electronics Planar DC/DC Transformer EQ/EQ(Plate) 25 User's Manual

Transcript
Planar DC/DC Transformer
ER/ER(Plate) 22
Power Capacity 50 to 150 W
Core Size (LxHxW) :27.5x13x23
Frequency Range :100K~300KHz
Unit : mm
Features
This planar x'fmr is suitable for forward DC/DC converter with resonance reset.
Mechanical Dimension :
Unit :mm
1.2
1.2
0.6
0.6
7.8 Max.
23.0 Max.
3.5 0.3
19.5 Max.
12.7 0.254
5.08 0.254
2. SCHEMATIC :
12
10
9
7
27.5 Max.
1
12
3
10
4
9
6
7
22.6 0.254
15.6 Max.
¡Ó
PRI
11.3 0.5
1
3
4
SEC
6
5.08 0.254
12.7 0.254
Electrical Characteristics:
PART NO.
PLT2215-001
TRANSFORMER
TURN
OPERATING
RATIO
FREQUENCY (1-3) : (4-6) : (10-12) : (7-9)
INDUCTANCE
L (1-3)
L (4-6)
9.0uH Min.
144.0uH Min.
250KHz
DIELECTRIC
STRENGTH
PRI TO SEC
2 : 8 : 2 : 2
2000Vdc
SEC TO CORE
2000Vdc
EQ/EQ(Plate) 25
Core Size (LxHxW) :30.5x13x26
AMBIENT
TEMPERATUR
+10 oC to +70oC
WEIGHT
13.5gr
Power Capacity 50 to 360 W
Unit : mm
Frequency Range :100K~500KHz
Features
This planar x'fmr is suitable for forward converter's transformer and for use on Linear Technology's LT1950.
Mechanical Dimension:
Unit: mm
1.0
1.0
1.6
2.0
11.75 0.5
0.2 0.1
25.6 Max.
15.87 0.5
5.29 0.5
2.65 0.5
4
3
2
1
20.32
12.7 0.5
ø2
2.79
25.4 0.5
6
7
8
2. SCHEMATIC :
2.79
4
5
12.7
5
2.12
18.5 Max.
12.7
30.5 Max.
5.29 0.5
8
10.16
8
3
7
1
6
4
5
SEC
4.23
4.23
PRI
1
2
15.87 0.5
Electrical Characteristics:
TRANSFORMER
PART NO.
FREQUENCY
L(2-3)
PLT2518-001
TURN
RATIO
OPERATING
INDUCTANCE
350KHz
97.0uH Min
(2-3) : (1-4) : (7-8) : (5-6)
5 :
2 :
6 : 6
DIELECTRIC
STRENGTH
PRI TO SEC
2250Vdc
AMBIENT
TEMPERATURE
+10oC to +70oC
DELTA ELECTRONICS, INC.
(TAOYUAN PLANT CPBG) 252, SAN YING ROAD, KUEISAN INDUSTRIAL ZONE, TAOYUAN SHIEN, 333, TAIWAN, R.O.C.
TEL: 886-3-3591968; FAX: 886-3-3591991
http://www.deltaww.com
79
WEIGHT
23.5gr