Download Aube Technologies ECONNECT TA7210 User's Manual
Transcript
69-2472EF-01 (Aube TA7210 System Installation Guide).book Page 12 Wednesday, June 29, 2011 1:15 PM Installation Guide Installer setup table Setup function Temperature unit Time format Minimum setpoint Maximum setpoint Programmable mode Keypad lock Zone name Adaptive Intelligent Recovery Anti-freeze Options °C / °F 12h / 24h 5°C to 30°C (41°F to 86°F) 5°C to 30°C (41°F to 86°F) On / Off None / Partial / All 1, ..., 57 On / Off On / Off Default setting °C 24h 5°C (41°F) 30°C (86°F) On None 52 On On To modify, see Page 12 Page 12 Page 13 Page 13 Page 14 Pages 15 Pages 16-17 Page 18 Page 18 To set the date & time, the schedule and the automatic daylight savings, refer to User’s Guide. Temperature unit / Time format Follow this procedure to select the temperature unit (°C or °F) and time format (12h or 24h). The time format selection is available only if the thermostat is in programmable mode. # Display Button Step 1) From the installer’s setup menu, press Ok to select the Format menu. 2) Press or to change the temperature unit. Press Ok. 3) Press or to change the time format. Press Ok. 12