Download A.O. Smith EQ / EQB Specification Sheet
Transcript
EQ / EQB Gas-fired residential / light commercial water heater EQ - 115/155/200/280/380 EQB - 115/155/200 Atmospheric water heater with thermal flue spillage protection and piezo ignition • Low noise level, suitable for installation in most locations • Ring base for easy installation and lower heat losses • Replaceable magnesium sacrificial anode • Safety thermostat • EQ 280/380 have access covers for waterside tank maintenance • EQB: maximum temperature setting of 81°C • Suitable for natural or LP gas • Optional ancillaries: Unvented kits • Destratification pump kit • Powered anode • Time clock kit • Flue fan kit • Solenoid valve kit Innovation has a name. EQ / EQB EQB 200 EQB 155 EQB 115 EQ 380 EQ 280 EQ 200 EQ 155 EQ 115 Technical specifications Gas data natural gas 2H (G20) Input* Output Inlet pressure Burner pressure Gas consumption** Diameter pilot orifice Diameter main orifice Max. flue gas temperature kW kW mbar mbar m3/h mm mm °C 9.3 7.4 20 12.5 0.9 2 x 0.27 2.35 255 11.3 9.0 20 12.5 1.1 2 x 0.27 2.60 200 18.3 14.0 20 10.5 1.7 2 x 0.27 3.5 160 23.1 16.0 20 11.5 2.2 2 x 0.27 3.9 255 27.4 19.2 20 10.0 2.6 2 x 0.27 4.5 290 9.3 7.4 20 12.5 0.9 2 x 0.27 2.35 255 11.3 9.0 20 12.5 1.1 2 x 0.27 2.60 200 18.3 14.0 20 10.5 1.7 2 x 0.27 3.5 160 kW kW mbar mbar kg/h mm mm °C 10.1 8.2 30 - 0.7 0.22 1.40 255 12.2 9.9 30 - 0.9 0.22 1.50 200 17.6 13.7 30 - 1.3 0.22 1.95 160 21.8 15.5 30 - 1.6 2 x 0.16 2.20 255 29.6 21.2 30 - 2.2 2 x 0.16 2.50 290 10.1 8.2 30 - 0.7 0.22 1.40 255 12.2 9.9 30 - 0.9 0.22 1.60 200 17.6 13.7 30 1.3 0.22 1.95 160 kW kW mbar mbar kg/h mm mm °C 9.8 7.9 37 - 0.7 0.22 1.40 255 11.8 9.6 37 - 0.8 0.22 1.50 200 17.2 13.4 37 - 1.2 0.22 1.95 160 20.9 14.8 37 - 1.5 2 x 0.16 2.20 255 26.6 19.0 37 - 1.9 2 x 0.16 2.50 290 9.3 7.6 37 - 0.7 0.22 1.40 255 11.7 9.5 37 - 0.8 0.22 1.60 200 17.6 13.7 37 1.2 0.22 1.95 160 l °C l l l l l/h min. l l l l l/h min. l l l l l/h min. 109 71 169 241 314 386 144 45 149 212 276 339 127 51 135 193 251 309 116 57 144 71 216 304 392 480 175 49 190 268 345 422 154 56 173 243 313 384 140 62 181 71 296 433 569 706 273 40 260 381 501 621 241 45 237 346 455 565 219 50 265 71 394 550 707 864 313 51 347 484 622 760 275 58 315 440 565 691 250 63 355 71 508 695 883 1070 375 57 447 612 777 942 330 65 406 556 706 856 300 71 109 81 169 241 314 386 144 45 149 212 276 339 127 51 135 193 251 309 116 57 144 81 216 304 392 480 175 49 191 268 345 422 154 56 173 243 313 384 140 62 181 81 296 433 569 706 273 40 260 381 501 621 241 45 237 346 455 565 219 50 1 8 256 382 499 156 1 8 196 256 52 57 580 1250 630 75 81 570 1580 650 Gas data butane 3+ (G30) Input* Output Inlet pressure Burner pressure Gas consumption** Diameter pilot orifice Diameter main orifice Max. flue gas temperature Gas data propane 3+ (G31) Input* Output Inlet pressure Burner pressure Gas consumption** Diameter pilot orifice Diameter main orifice Max. flue gas temperature Draw-off capacity Storage capacity Max. temperature setting 30 min. ∆T=44°C 60 min. ∆T=44°C 90 min. ∆T=44°C 120 min. ∆T=44°C Continuous ∆T=44°C Heating-up time ∆T=44°C 30 min. ∆T=50°C 60 min. ∆T=50°C 90 min. ∆T=50°C 120 min. ∆T=50°C Continuous ∆T=50°C Heating-up time ∆T=50°C 30 min. ∆T=55°C 60 min. ∆T=55°C 90 min. ∆T=55°C 120 min. ∆T=55°C Continuous ∆T=55°C Heating-up time ∆T=55°C General Anodes Maximum working pressure Maximum weight - bar kg 156 196 Shipping data Weight empty Weight incl. packaging Width packaging Height packaging Depth packaging * Gas data on gross value ** Gas consumption at 15°C and 1013.25 mbar kg kg mm mm mm 47 51 530 1140 570 52 57 580 1250 630 75 81 570 1580 650 117 135 780 1640 870 144 162 780 1830 870 47 51 530 1140 570 EQ / EQB EQ/EQB 115 EQ/EQB 155 EQ 200 EQB 200 EQ 280 EQ 380 Dimensions A 1280 1370 1600 1670 1585 1780 B 1120 1210 1440 1540 1450 1640 D 465 515 515 515 645 675 E 545 595 595 605 735 765 G 80 80 100 100 130 130 K 325 325 325 380 375 375 M 1180 1270 1500 1590 1505 1685 N 1180 1270 1500 1590 1505 1685 R 230 230 230 255 285 285 S 945 1030 1265 1380 1280 1460 EQ / EQB 1 Cold water 2 Hot water 3 4 5 Gas control Tank drain valve T&P valve 3/4 - 14 NPT (EQ 280: 1 -11.5 NPT) (EQ 380: 1 1/4 - 11.5 NPT) 3/4 - 14 NPT (EQ 280: 1-11.5 NPT) (EQ 380: 1 1/4 -11.5 NPT) Rp 1/2 3/4 - 14 NPT 3/4 - 14 NPT Dimensions in mm. All EQ water heaters receive a five years warranty on the tank and one year on parts. All EQB water heaters have a one year warranty period. EQ / EQB Installation diagrams EQ / EQB 1 Pressure reducing valve 3 T&P valve 4 Stop valve 5 Non-return valve 6 Circulation pump 9 Drain valve 10 Gas cock 11 Isolating valve 14 Hot water outlets 15 Expansion relief valve 16 Expansion vessel 17 Three way valve 18 Water tank 19 Float valve A B C D E H Cold water Hot water Return circulation Gas supply Overflow pipe Expansion vent pipe A.O. Smith unvented system kits utilise combination valves. An EQ / EQB water heater should be installed in accordance with local standards and ventilation requirements (category B11BS). Further installation and connection details can be found in the Installation & Commissioning Manual. Data subject to change INT/0808/EQ/02 Terms and conditions apply, please refer to our website. For the parts numbers of components please refer to the “Maintenance and accessories” tab. www.aosmithinternational.com