Transcript
RB610 Break Away Cluster Relay Module Rev. DSRB610 - B11I Overview • Break away relays. Specifications • Current draw 50mA. • 10 amp/120VAC or 28VDC SPDT contacts. • Screw terminals accommodate up to 12 gauge wire. • 12VDC or 24VDC selectable operation. • Each cluster contains six (6) relay modules which can easily be separated. Board Dimensions (approximate) 8”L x 4.5”W x 1.25”H Mounting Diagram 0.66" Ø0.156" 1.05" 1.6" 2.0" Altronix Corp. - 140 58th Street, Brooklyn, NY 11220 • 718-567-8181 • 888-258-7669 • altronix.com