HUBER+SUHNER® DATA SHEET Mm
Data Line Protector: 3414.99.0007B pou: IP
Description
Data Line Protector Symmetric Pair
Benefits
Patch cable included
Hybrid Protector
Shield and ground separated
Power over Ethernet
All lines protected
Product Configuration
Main path connectors
Mounting and grounding
Technical Data
Electrical Data
Impedance
Frequency range
Insertion loss
Voltage rating
Current rating
Current handling capability
Protection level
Clamping voltage
Mechanical Data
Weight
Environmental Data
Operating temperature
Waterproof degree
2002/95/EC (RoHS)
Material Data
Piece Parts
Body
Related Documents
Outline drawing
Mounting instruction
Document: DOC-0000777783 E.OO
RJ45 jack 8-Pin jack (female) - RJ45 jack 8-Pin jack (female) (unprotected side - protected side)
M4 (M=screw)
100 ©2
DC to 100 MHz
< 0.5 dB
per pair + 6 \/
per pair 1.5 A max
wire - wire 0.1 kA (test pulse 8/20 ps)
wire - ground 2.5 КА (test pulse 8/20 jus)
shield - ground 5 KA (test puise 8/20 us)
wire - wire 20 V typically (test pulse 4 kV 1.2/50 us / 2 kA 8/20 us)
wire - ground 700 V typically (test puise 4 kV 1.2/50 jus / 2 kA 8/20 us)
shield - ground 700 V typically (test pulse 4 kV 1.2/50 jus / 2 kÀ 8/20 us)
wire - wire 15V
wire - ground 90 V
shield - ground 90 V
709
-40 °С 10 +85 °С
IP 20 (according to 1ЕС 60529, data refer to the coupled state)
Telecom compliant
Material Surface Plating
Aluminium Chromatized
DOU-00070124.1
DOC-0000228433
Issued: 31.03.05 Uncontrolled Copy Page 1/2
HUBER+SUHNER® DATA SHEET ¿ws
Data Line Protector: 3414.99.0007B cn Nand
Additional Information
Remarks
Twisted Pair Surge Protector (1SO 11801. ENS0173. EIA/TIA 568)
Class D specified by GHMT
Network Standards: 10BASE-T / 100BASE-TX / 100BASE-T4 / 1000BASE-T / ATM-25 / ATM-51 / ATM-155 /
100VG-AnyLan / TR-4 / TR-16 / TP-PMD
For applications with "Data Terminal Equipment Powered via Media Dependent Interface" (IEEE 802.3af)
Circuit Diagram
Unprotected side Protected side
A — тн
Г "T4 к
(7 4 Now canacitance 17 |
| 106 apaecor PE NS AS à:
| | | |
1 - o | 1
2 2
o |
1 | = = = == | I
I 13 | | 3 I
I | | 1 1 1
|| № *i |! |
I = - Ta — ll = I
I 3 6
| E | | E |
I I
| à, == Là |
| & | & Ÿl | * | |
I I | I I I
| Y 4 |
BT] 518
| E 1 12 |
El aml = Raa Lam =
ı 317 + 3 715 |
ы 1 ! I uam 1
| FI | | ag |
— | 1 i =
NT (7)
I 1
| L q se — — FT
I 2 Pale GOT |
| --—--—--—Huy—--— e —
External ground
on CH) HUBER-SUHNER
HUBER+ SUHNER is certified according to 130 2001 and [30 14001
HUBER+SUHNER AG
WAN ER! RF Protection
lt is exclusively in written agreements that we provide our customers with warrants and 9100 Herisau, Switzerland
representations as to the technical contained specifications and/or the fitness for any particular Phone +41 (0)71 353 41 11
purpose. The facts and figures herein are carefully compiled to the best of our knowledge, but they are
intended for general informational purposes only. Fax h м e 353 45 90
Www nubersunner.com
HUBER+SUHNER — Excellence in Connectivity Solutions
Document: DOC-0000227283 E.00 Issued: 31.03.05 Uncontrolled Copy Page 2/2
Related documents