Download APC Smart-UPS VT
Transcript
| | 20.00 [508] CLEARANCE FOR VENTILATION 13.75 91.79 . — - [349] 7 806) _ 1 a _ | AT Te. - J ° * Ù lo of | 36.00 [914] 36.00 [914] —— MIMIMUM = E es -— MIMIMUM —— SERVICE SERVICE 5.34 0 CLEARANCE CLEARANCE (i | [36 : |" 1 Tm TYP ° ° | о o | 1] |° ° | lo ol 08.79 ; 00|b ce [1 497 | o o № | | ‚ | | "TE oo 37.16 № о! [944 | I | № ol loo ool lo ol Ñ | ^. HH. | UE + | o о | 1 17 LES ON E, NU & FRONT VIEW FRONT VIEW SIDE VIEW (WITH DECORATIVE FRONT) NOTES: 1. ALL DIMENSIONS ARE IN INCHES [MILLIMETERS]. 2. FRONT AND REAR SERVICE ACCESS 3. CONDUIT ENTRY IS TOP OR BOTTOM OF UNIT. 4. UNIT WEIGHT IS 236 LBS [107 kg] THIS DRAWING AND SPECIFICATIONS HEREIN ARE THE TITLE: SMART-UPS VT 20-30kVA DG NO: SBPSUI0K30FC1M1—MM1 fe 1 ® . ‚ PROPERTY OF AMERICAN POWER CONVERSION AND SHALL NOT о MBP S SHIPPED WITHOUT SIDE PANELS BE COPIED, REPRODUCED OR USED IN WHOLE OR IN PART OUT POWER DISTRIBUTION PANEL. APC DURING THE INSTALLATION IT ADAPTS ONE SIDE PANEL OF UPS AS THE BASIS FOR THE MANUFACTURE OR SALE OF ITEMS. 208V, 3PH, 20-30KVA DRAIN Br: JAYAPRAKASH 11/30/05 6. INSTALLATION MUST COMPLY WITH ALL APPLICABLE NATIONAL AND LOCAL CODES ae a MAIN_MECHANICAL CHECKED BY: M.LEPARD MY. MN SUBJECT TO CHANGE WITHOUT NOTICE. PROJECT: SUBMITTAL DRAWINGS | SHEET 1 OF 5 | ENGINEER: L.ROZENBERG 11/30/05 WEST KINGSTON, RI 02892 25 INPUT/OUTPUT ¢ 3 INCH [19mm] KNOCKOUTS NOTES: 13.75 | 349] © | | 7.04 |179 | © © | COCO í O O OO 6.55 COTO 166] CC CCC COCO | FRONT TOP VIEW (ENLARGED) N 1. ALL DIMENSIONS ARE IN INCHES [MILLIMETERS]. 2. SOME STRUCTURAL DETAILS IN THESE VIEWS HAVE BEEN OMITTED FOR CLARITY, 3. INSTALLATION MUST COMPLY WITH ALL APPLICABLE NATIONAL AND LOCAL CODES. SWIVEL rai 1.04 26] TYP CASTERS 4 PLACES 24.04 [611] — 25 INPUT/OUTPUT ¢ 3 INCH [19mm] KNOCKOUTS 29.83 | 758] ADJUSTABLE LEGS 4 PLACES a BOTTOM VIEW (ENLARGED) mE 7 THIS DRAWING AND SPECIFICATIONS HEREIN ARE THE PROPERTY OF AMERICAN POWER CONVERSION AND SHALL NOT BE COPIED, REPRODUCED OR USED IN WHOLE OR IN PART, AS THE BASIS FOR THE MANUFACTURE OR SALE OF ITEMS WITHOUT WRITTEN PERMISSION FROM APC. THIS DRAWING IS BASED UPON LATEST AVAILABLE INFORMATION AND 1S SUBJECT TO CHANGE WITHOUT NOTICE. PIE ie MORT UPS VT 20-30 et SBPSUROK3OFCTMI-WM2 "1 WITHOUT POWER, DISTRIBUTION PANEL | opor JAYAPRAKASH 11/30/05 TOP AND BOTTOM VIEWS CHECKED BY: M.LEPARD 11/30/05 PROJECT: SUBMITTAL DRAWINGS SHEET 2 OF 5 | ENGINEER: L.ROZENBERG 11 /30/05 APC AMERICAN POWER CONVERSIÓN 132 FAIRGROUNDS RD WEST KINGSTON, № 02692 NOTES: UPS INPUTS TO Q1 SWITCH 47.76 [1213] UPS OUTPUTS TO Q2 SWITCH 57.09 [942] 26.17 [665] MAINS UTILITY TO POWER TERMINAL BLOCK 1. CONDUIT ENTRY IS TOP OR BOTTOM OF UNIT. 2. SBP CAN BE MECHANICALLY CONNECTED TO EITHER THE LEFT OR THE RIGHT SIDE OF THE UPS 5. INSTALLATION MUST COMPLY WITH ALL APPLICABLE NATIONAL AND LOCAL CODES FRONT VIEW (DOOR REMOVED) \ 7 lo ol o | a N L3 L2 Li e — HQ Jo H FA FA — LS 12 L1 +f je N L3 L2 L1 — © © [2 1 en o 10 | ol UD, e o | o N Li L2 13 o | of CONTROL WIRES lo] LANG o o OJOJOIO MAINS UTILITY с TO GROUND © lo a IS BASED UPON LATEST THIS DRAWING AND SPECIFICATIONS HEREIN ARE THE PROPERTY OF AMERICAN POWER CONVERSION AND SHALL NOT BE COPIED, REPRODUCED OR USED IN WHOLE OR IN PART, AS THE BASIS FOR THE MANUFACTURE OR SALE OF ITEMS WITHOUT WRITTEN PERMI SSION FROM APC. THIS DRAWING AVAILABLE INFORMATION AND IS SUBJECT ТО CHANGE WITHOUT NOTICE. TILE SMART-UPS VT 20-30kVA DWG NO: REV. FLOOR MOUNT MAINTENANCE BYPASS PANEL SBPSUZ20K30FC1M1—ME | 1 WITHOUT POWER DISTRIBUTION PANEL 208V, 3PH, 20-S0KVA DRAWN BY: JAYAPRAKASH 11/30/05 INTERNAL VIEW—FRONT CHECKED BY: M.LEPARD 11/30/05 PROJECT: SUBMITTAL DRAWINGS | SHEET 3 OF 5 | ENGINEER: LROZENBERG 11/30/05 APC AMERICAN POWER CONVERSION 132 FAIRGROUNDS RD WEST KINGSTON, RI 02892 O OFF AC INPUT o =z Q1 UPS Input Input UPS O OFF Output Static Bypass Q3 Bypass O OFF «| -—> Qe UPS output LOAD PANEL, MIMIC DIAGRAM (NORMAL OPERATING MODE) THIS DRAWING AND SPECIFICATIONS HEREIN ARE THE TITLE: SMART-UPS VT 20-30kVA DWG NO: REV. ® PROPERTY OF AMERICAN POWER CONVERSION AND SHALL NOT) — FLOOR MOUNT MAINTENANCE BYPASS PANEL SBPSUZ0K30FCTM1—MD 1 APC BE COPIED, REPRODUCED OR USED IN WHOLE OR IN PART, WITHOUT POWER DISTRIBUTION PANEL AS THE BASIS FOR THE MANUFACTURE OR SALE OF ITEMS 208V, 3PH, 20—30kVA DRAWN BY: JAYAPRAKASH 11/30/05 WITHOUT WRITTEN PERMISSION FROM APC. THIS DRAWING MIMIC DIAGRAM CHECKED BY: M.LEPARD 11/30/05 AMERICAN POWER CONVERSION IS BASED UPON LATEST AVAILABLE INFORMATION AND IS 132 FAIRGROUNDS RD SUBJECT TO CHANGE WITHOUT NOTICE. PROJECT: SUBMITTAL DRAWINGS | SHEET 4 OF 5 | ENGINEER: L.ROZENBERG 11/30/05 WEST KINGSTON, RI 02892 / / / / = 5 Se ® oY s © 7 © = => ® © < ( < < «< ® ® s © s © DD DD >> EDS ® s © ED N. ISOMETRIC VIEW THIS DRAWING AND SPECIFICATIONS HEREIN ARE THE TITLE: SMART-UPS VT 20-30kVA DWG NO; REV. ® PROPERTY OF AMERICAN PONER CONVERSION AND SHALL NOT FLOOR MOUNT MAINTENANCE BYPASS PANEL SBPSU20KS0FC1M1-ISO 1 NPC BE COPIED, REPRODUCED OR USED IN WHOLE OR IN PART, WITHOUT POWER DISTRIBUTION PANEL AS THE BASIS FOR THE MANUFACTURE OR SALE OF ITEMS 208V, 3PH, 20—30kVA DRAWN BY: JAYAPRAKASH 11/30/05 WITHOUT WRITTEN PERMISSION FROM APC. THIS DRAWING ISOMETRIC VIEW CHECKED BY: M.LEPARD 11/30/05 AMERICAN POWER CONVERSION IS BASED UPON LATEST AVAILABLE INFORMATION AND IS 132 FAIRGROUNDS RD SUBJECT TO CHANGE WITHOUT NOTICE. PROJECT: SUBMITTAL DRAWINGS | SHEET 5 OF5 | ENGINEER: L.ROZENBERG 11/30/05 WEST KINGSTON, RI 02892
Related documents