Download APC Smart-UPS VT

Transcript
 |
|
20.00 [508]
CLEARANCE
FOR VENTILATION
13.75 91.79
. —
- [349] 7 806)
_ 1 a _
|
AT Te.
- J ° * Ù
lo of |
36.00 [914] 36.00 [914]
—— MIMIMUM = E es -— MIMIMUM ——
SERVICE SERVICE
5.34 0 CLEARANCE CLEARANCE
(i | [36 : |" 1
Tm TYP ° °
| о o
| 1] |° ° |
lo ol 08.79 ; 00|b ce
[1 497 |
o o № |
| ‚ | |
"TE oo
37.16 № о!
[944 | I |
№ ol
loo ool
lo ol Ñ |
^. HH. | UE + | o о |
1 17 LES ON E, NU &
FRONT VIEW FRONT VIEW SIDE VIEW
(WITH DECORATIVE FRONT)
NOTES:
1. ALL DIMENSIONS ARE IN INCHES [MILLIMETERS].
2. FRONT AND REAR SERVICE ACCESS
3. CONDUIT ENTRY IS TOP OR BOTTOM OF UNIT.
4. UNIT WEIGHT IS 236 LBS [107 kg] THIS DRAWING AND SPECIFICATIONS HEREIN ARE THE TITLE: SMART-UPS VT 20-30kVA DG NO: SBPSUI0K30FC1M1—MM1 fe 1 ®
. ‚ PROPERTY OF AMERICAN POWER CONVERSION AND SHALL NOT
о MBP S SHIPPED WITHOUT SIDE PANELS BE COPIED, REPRODUCED OR USED IN WHOLE OR IN PART OUT POWER DISTRIBUTION PANEL. APC
DURING THE INSTALLATION IT ADAPTS ONE SIDE PANEL OF UPS AS THE BASIS FOR THE MANUFACTURE OR SALE OF ITEMS. 208V, 3PH, 20-30KVA DRAIN Br: JAYAPRAKASH 11/30/05
6. INSTALLATION MUST COMPLY WITH ALL APPLICABLE NATIONAL AND LOCAL CODES ae a MAIN_MECHANICAL CHECKED BY: M.LEPARD MY. MN
SUBJECT TO CHANGE WITHOUT NOTICE. PROJECT: SUBMITTAL DRAWINGS | SHEET 1 OF 5 | ENGINEER: L.ROZENBERG 11/30/05 WEST KINGSTON, RI 02892
25 INPUT/OUTPUT
¢ 3 INCH [19mm]
KNOCKOUTS
NOTES:
13.75
| 349]
© | |
7.04
|179 |
© © |
COCO í
O O OO 6.55
COTO 166]
CC CCC
COCO |
FRONT
TOP VIEW (ENLARGED)
N
1. ALL DIMENSIONS ARE IN INCHES [MILLIMETERS].
2. SOME STRUCTURAL DETAILS IN THESE VIEWS HAVE BEEN OMITTED FOR CLARITY,
3. INSTALLATION MUST COMPLY WITH ALL APPLICABLE NATIONAL AND LOCAL CODES.
SWIVEL
rai
1.04
26]
TYP
CASTERS
4 PLACES
24.04
[611]
— 25 INPUT/OUTPUT
¢ 3 INCH [19mm]
KNOCKOUTS
29.83
| 758]
ADJUSTABLE LEGS
4 PLACES
a
BOTTOM VIEW (ENLARGED) mE
7
THIS DRAWING AND SPECIFICATIONS HEREIN ARE THE
PROPERTY OF AMERICAN POWER CONVERSION AND SHALL NOT
BE COPIED, REPRODUCED OR USED IN WHOLE OR IN PART,
AS THE BASIS FOR THE MANUFACTURE OR SALE OF ITEMS
WITHOUT WRITTEN PERMISSION FROM APC. THIS DRAWING
IS BASED UPON LATEST AVAILABLE INFORMATION AND 1S
SUBJECT TO CHANGE WITHOUT NOTICE.
PIE ie MORT UPS VT 20-30 et SBPSUROK3OFCTMI-WM2 "1
WITHOUT POWER, DISTRIBUTION PANEL | opor JAYAPRAKASH 11/30/05
TOP AND BOTTOM VIEWS CHECKED BY: M.LEPARD 11/30/05
PROJECT: SUBMITTAL DRAWINGS SHEET 2 OF 5 | ENGINEER: L.ROZENBERG 11 /30/05
APC
AMERICAN POWER CONVERSIÓN
132 FAIRGROUNDS RD
WEST KINGSTON, № 02692
NOTES:
UPS INPUTS TO
Q1 SWITCH
47.76
[1213]
UPS OUTPUTS TO
Q2 SWITCH
57.09
[942]
26.17
[665]
MAINS UTILITY TO
POWER TERMINAL BLOCK
1. CONDUIT ENTRY IS TOP OR BOTTOM OF UNIT.
2. SBP CAN BE MECHANICALLY CONNECTED TO EITHER THE LEFT OR THE RIGHT SIDE OF THE UPS
5. INSTALLATION MUST COMPLY WITH ALL APPLICABLE NATIONAL AND LOCAL CODES
FRONT VIEW (DOOR REMOVED)
\
7
lo ol
o
| a
N L3 L2 Li e —
HQ Jo
H FA FA —
LS 12 L1
+f je
N L3 L2 L1
— © ©
[2 1 en o
10 | ol
UD, e
o | o N Li L2 13 o | of CONTROL WIRES
lo] LANG o
o OJOJOIO
MAINS UTILITY
с TO GROUND
©
lo
a
IS BASED UPON LATEST
THIS DRAWING AND SPECIFICATIONS HEREIN ARE THE
PROPERTY OF AMERICAN POWER CONVERSION AND SHALL NOT
BE COPIED, REPRODUCED OR USED IN WHOLE OR IN PART,
AS THE BASIS FOR THE MANUFACTURE OR SALE OF ITEMS
WITHOUT WRITTEN PERMI
SSION FROM APC. THIS DRAWING
AVAILABLE INFORMATION AND IS
SUBJECT ТО CHANGE WITHOUT NOTICE.
TILE SMART-UPS VT 20-30kVA DWG NO: REV.
FLOOR MOUNT MAINTENANCE BYPASS PANEL SBPSUZ20K30FC1M1—ME | 1
WITHOUT POWER DISTRIBUTION PANEL
208V, 3PH, 20-S0KVA DRAWN BY: JAYAPRAKASH 11/30/05
INTERNAL VIEW—FRONT CHECKED BY: M.LEPARD 11/30/05
PROJECT: SUBMITTAL DRAWINGS | SHEET 3 OF 5 | ENGINEER: LROZENBERG 11/30/05
APC
AMERICAN POWER CONVERSION
132 FAIRGROUNDS RD
WEST KINGSTON, RI 02892
O OFF
AC
INPUT
o
=z
Q1
UPS Input
Input
UPS
O OFF
Output
Static
Bypass
Q3
Bypass
O OFF
«| -—>
Qe
UPS output
LOAD
PANEL,
MIMIC DIAGRAM
(NORMAL OPERATING MODE)
THIS DRAWING AND SPECIFICATIONS HEREIN ARE THE TITLE: SMART-UPS VT 20-30kVA DWG NO: REV. ®
PROPERTY OF AMERICAN POWER CONVERSION AND SHALL NOT) — FLOOR MOUNT MAINTENANCE BYPASS PANEL SBPSUZ0K30FCTM1—MD 1 APC
BE COPIED, REPRODUCED OR USED IN WHOLE OR IN PART, WITHOUT POWER DISTRIBUTION PANEL
AS THE BASIS FOR THE MANUFACTURE OR SALE OF ITEMS 208V, 3PH, 20—30kVA DRAWN BY: JAYAPRAKASH 11/30/05
WITHOUT WRITTEN PERMISSION FROM APC. THIS DRAWING MIMIC DIAGRAM CHECKED BY: M.LEPARD 11/30/05 AMERICAN POWER CONVERSION
IS BASED UPON LATEST AVAILABLE INFORMATION AND IS 132 FAIRGROUNDS RD
SUBJECT TO CHANGE WITHOUT NOTICE. PROJECT: SUBMITTAL DRAWINGS | SHEET 4 OF 5 | ENGINEER: L.ROZENBERG 11/30/05 WEST KINGSTON, RI 02892
/
/
/
/
=
5
Se
®
oY
s ©
7
©
=
=>
®
©
<
(
<
<
«<
®
®
s ©
s ©
DD DD >> EDS
®
s ©
ED
N.
ISOMETRIC VIEW
THIS DRAWING AND SPECIFICATIONS HEREIN ARE THE TITLE: SMART-UPS VT 20-30kVA DWG NO; REV. ®
PROPERTY OF AMERICAN PONER CONVERSION AND SHALL NOT FLOOR MOUNT MAINTENANCE BYPASS PANEL SBPSU20KS0FC1M1-ISO 1 NPC
BE COPIED, REPRODUCED OR USED IN WHOLE OR IN PART, WITHOUT POWER DISTRIBUTION PANEL
AS THE BASIS FOR THE MANUFACTURE OR SALE OF ITEMS 208V, 3PH, 20—30kVA DRAWN BY: JAYAPRAKASH 11/30/05
WITHOUT WRITTEN PERMISSION FROM APC. THIS DRAWING ISOMETRIC VIEW CHECKED BY: M.LEPARD 11/30/05 AMERICAN POWER CONVERSION
IS BASED UPON LATEST AVAILABLE INFORMATION AND IS 132 FAIRGROUNDS RD
SUBJECT TO CHANGE WITHOUT NOTICE. PROJECT: SUBMITTAL DRAWINGS | SHEET 5 OF5 | ENGINEER: L.ROZENBERG 11/30/05 WEST KINGSTON, RI 02892