Download APC NetShelter SX 42U 600mm Wide x 1070mm Deep Enclosure with Sides Black
Transcript
600 MINIMUM COOLING 1991 THIS PANEL IS CONSTRUCTED WITH PERFORATED MATERIAL FOR ARR FLOW C0000 C ) C ) DY Y Y UJ -«— PER U SPACE | | | | | | | TOTAL OPEN AREA | | | 141.20 SQ.CM) | | | | | | | | | | | | 5930.20 SQ.CM || E (OPEN AREA | | | D ——.— FRONT VIEW 1021 TT > >, / Y i 53 9 De 27 : Е 1051 ея о DEPTH 0 Ds W/O DOORS ао ое o@9 - ó - Po / 139" MAX / 588 3 PLACES / ~ ~~ — _ р -—1244 1034—— TOP VIEW (DOORS FULLY OPEN) FOR RM PDU — MOUNTING DETAILS REF. VIEW A 1000 AND COOLING CLEARANCE 102 — 3 SIDE BRACES 1092 —., 81 HOLE-TO-HOLE _ AT FACTORY SETTING — — | MINIMUM SERVICE 1000 MINIMUM SERVICE AND COOLING CLEARANCE [-— — 2 PLACES SIDE VIEW NOTES: 1. ALL DIMENSIONS ARE IN MILLIMETERS. THIS PANEL IS CONSTRUCTED WITH PERFORATED MATERIAL | FOR AR FLOW ! \ 00000 С ) С ) С ) С ) 00000 TOTAL OPEN AREA 6689.80 SQ.CM (OPEN AREA PER U SPACE 159.30 SQ.CM) REAR VIEW 2. CABLE ENTRY IS TOP OR BOTTOM OF UNIT. 3. FRONT AND REAR SERVICE ACCESS. 4. NET WEIGHT OF UNIT IS 124.5 Kg. 5. INSTALLATION MUST COMPLY WITH NATIONAL AND LOCAL ELECTRICAL REGULATIONS. 0.37 O=0=0=0=0=0=0=0=0=0=0=0=0=0=0=1[ AD < ьо=еое= соо ое ое ое ое 02 0 = о = о = 0 = 0 = 0 = | 1 SQUARE / 107 _ { el HE 44 Q o: 75 CONTINUOUS PATTERN EXCEPT AT SIDE | BRACES o 0 I 1 a 311 ` 5 PALCES 1956 | ñ ñ 0 0 Io 1 Tri ITA | |! 200 | |1 4 PLACES | o| Je | 111 ao 3 PLACES 0 Ce Ti If 11 eN | | I 95 0 0 a SL | SL )?)| Я | | 114 i | y | VIEW=A RMPDU MOUNTING DETAILS SUBJECT TO CHANGE WITHOUT NOTICE. THIS DRAWING AND SPECIFICATIONS HEREIN ARE THE PROPERTY OF AMERICAN POWER CONVERSION AND SHALL NOT BE COPIED, REPRODUCED OR USED IN WHOLE OR IN PART, AS THE BASIS FOR THE MANUFACTURE OR SALE OF [TEMS WITHOUT WRITTEN PERMISSION FROM APC. THIS DRAWING IS BASED UPON LATEST AVAILABLE INFORMATION AND IS ME NETSHELTER SX 42U ENCLOSURE | PS NO: AR3100 — ММ! [®_ WITH SIDES, 600mm W x 1070mm D DRAWN: BALAMURUGAN 07/02/06 MAIN MECHANICAL CHECKED: JMATTLIN 15/03/06 Pg Г PROJECT: SUBMITTAL DRAWING |SHEET 1 OF 3 (ENGINEER: C.LARSEN/SWAGH | |15/озуов |< — APC AMERICAN POWER CONVERSION 132 FAIRGROUNDS RD WEST KINGSTON, RI 02892 240 75 E. - — 2 OPENINGS 3 OPENING REAR (ob pea =. = E еб ’ es a 500 e ! À Г 7 À В oO о в = FRAME OPENING _ SAR о О О о y 2 0PENNGS|| kb 0905000080 81 185 (FRONT de REAR) | CLEARANCE | Oe 0 OO | de НН | е O О о 895 зо о о в OPENING do 0 О où BETWEEN - це 0 0 op FRAME —— 49 o 0 oO ok VERTICALS Tm a 0 Cl O |x 51 892 5 0 o ol —| | -=— SIDE ”0U” 737 OPENING ae О 054 1 54 SPACE RAIL TO RAIL W/0 оо о в 5 OPENINGS 550 (OUTSIDE) ROOF о Do OPENING CAN BE ADJUSTED зе © Dor BETWEEN TO 934 MAX AND loa a of | RAILS +05 540 MIN o © goal 177 AT FACTORY - SER EN 390. —] WITH 6 INCREMENTS IE: D sf || 5 OPENINGS SETTING mao О О a | y oO g as 450 MIN OPENING M UoooooooŸÿ ©” PER ElA 310 so go [= авс о oO | зв | |. | | À | 0 @:€ 5 2.00 NY KT > Ñ JD 91 | =) ] FRAME 567 VERTICAL FRONT OPENING W/O ROOF — 64 FRONT BEZEL CLEARANCE CAN BE ADJUSTED | TOP VIEW SECTION 8-8 T0 800 MAX AND CABLE OPENINGS (VIEW FROM INSIDE CABINET, WITH 6 (COVERS REMOVED) LOOKING DOWN) INCREMENTS NOTES: |" ese ox 420 ENCIOSURE DONE ARS100 — MM2 [7 — 1. ALL DIMENSIONS ARE IN MILLIMETERS. BE COPED, REPRODUCED OF USED IN WHOLE OR IN PART 600mm. W. x 1070mm D [oran BALAMURUGAN | To7/02/06 2. INSTALLATION MUST COMPLY WITH NATIONAL AND LOCAL ELECTRICAL REGULATIONS. CL eye TOP AND SECTION VIEWS |CHECKED: JMRTILN | 18/03/06 | "LOE | MN OWN SUBJECT TO CHANGE WITHOUT NOTICE. PROJECT: SUBMITTAL DRAWING -|SHEET 2 0F 3 ENGINEER: C.LARSEN/S.WAGH 15/03/06 Y WEST KINGSTON, RI 02892 /\ ~— 205 ——— 190 PALLET BRACKET (2) 301T-DOWN A. ADJUSTABLE LEVELING FEET (4) FRONT 7 ADJUSTABLE LEVELING FEET (4) A | 1022 1106 1152 1151 LEVELING FEET 67 CENTER TO LE CENTER 119 BOTTOM OPENING 1022 1105 941 CASTERS 729 831 776 CENTER TO CENTER 70 =— y Y 4 N Y Г > o _ © 0 Oo _ | _ © - © © ©_0© ye. 9 e eo © y 2 о ® © © ` 1 Oo % O [© 2 L | © O © 0, Y Y | O RE R O | REAR — -— 190 — -—— 300 — 401 -— CASTERS — 572 CETNER TO CENTER BOTTOM VIEW BOTTOM VIEW (WITH PALLET BRACKETS (WITH OPTIONAL BOLT—-DOWN BRACKETS (CAN BE USED FOR ANCHORING)) FOR ANCHORING) NOTES: 1. ALL DIMENSIONS ARE IN INCHES [MILLIMETERS]. THIS DRAMNG AND SPECIFICKTONS HEREN ARE THE | Ш MILE: NETSHELTER SX 42U ENCLOSURE | PS NO: AR3100 — MM3 REV. ® /\ 2 ANCHORING BRACKETS CAN BE INSTALLED EITHER INSIDE OR OUTSIDE THE NETSHELTER. BE COPIED, REPRODUCED OR USED IN WHOLE OR IN PART, WITH SIDES, DRAWN: BALAMURUCAN 07/02/06 APC WHO REN PERMISSION: FROM APC. THIS DRM i oom mon vee ) CHECKED: J.MATTLIN 15/03/06 | PROJECTION AMERICAN POWER CONVERSION 3. INSTALLATION MUST COMPLY WITH ALL APPLICABLE NATIONAL AND LOCAL CODES. UN ; , 103/06 | TT PAN PONER COMER SUBJECT TO CHANCE WITHOUT NOTICE. PROJECT: SUBMITTAL DRAWING [SHEET 3 OF 3 |ENGINEER: C.LARSEN/S.WAGH 15/03/06 | [0 WEST KINGSTON, RI 02892 1.42 36 TYP ADJUSTABILITY RANGE ENLARGED VIEW NOTES: 1. ALL DIMENSIONS ARE IN INCHES [MILLIMETERS]. A 2. THIS DRAWING REPRESENTS NETSHELTER WITH OPTIONAL TROUGH AND PARTITION ACCESSORIES. PARTITION CABLING AREA CAN BE ADJUSTED TO MEET CUSTOMERS REQUIREMENTS. 3 INSTALLATION MUST COMPLY WITH ALL APPLICABLE NATIONAL AND LOCAL CODES. (0 ooooooo) TOP VIEW ee \./ : : FRONT VIEW PARTITIÓNS — (OPTIONAL) | / [a ——— 19.88 — 6.15 505] [156] CABLE TROUGH 7 (OPTIONAL) \ 4.78 [121] SUBJECT TO CHANGE WITHOUT NOTICE. PROJECT: SUBMITTAL DRAWINGS |SHEET 4 0F4 | ENGINEER: C LARSEN/S WAGH 03/23/06 | || || 7.23 | | OI, [184] 4.33 | [110] | 85.65 | [2175] | = LE | ww EW - — wd 1 SIDE VIEW REAR VIEW THIS DRAWING AND SPECIFICATIONS HEREIN ARE THE TITLE: DWG NO: REV. ® PROPERTY OF AMERICAN POWER CONVERSION AND SHALL NOT NETSHELTER SX 42U ARS100—MM4 | — NPC BE COPIED, REPRODUCED OR USED IN WHOLE OR IN PART, AS THE BASIS FOR THE MANUFACTURE OR SALE OF ITEMS ENCLOSURE WITH SIDES, 24Wx42DC | DRAWN BY: B ZAHN 03/21/06 WITHOUT WRITTEN PERMISSION FROM APC. THIS DRAWING WIRE TROUGH AND PARTITIONS VIEWS | CHECKED Br: J MATILIN 03/23/06) - AMERICAN PONER CONVERSION IS BASED UPON LATEST AVAILABLE INFORMATION AND IS 132 FAIRGROUNDS RD WEST KINGSTON, RI 02892
Related documents