Remove the top part of the liquid additive compartment.
Clean all the parts with water.
MAX
5.
6.
WARNING!
Before unscrewing the pump cover, switch the appliance off and
remove the mains plug from the
socket.
DRAIN PUMP
The pump should be inspected regularly
and particularly if:
• the appliance does not empty and/or
spin;
• the appliance makes an unusual noise
during draining due to objects such as
safety pins, coins etc. blocking the
pump;
• a problem with water draining is detected (see chapter “Troubleshooting” for
more details).
A
Clean the dispenser recess with a
brush.
Put back the dispenser in the recess.
Proceed as follows:
1. Unplug the appliance.
2. If it is necessary, wait until the water
has cooled down.
3.
Place a container close to the pump
to collect any spillage.
4.
Release the emergency emptying
hose (B), place it in the container and
remove its cap cover.