THERMAL RE-SET
Themachineissuppliedwithathermalre-setswitch.Theswitchwillactivate
whenthemachinebecomestoohot.Thisconditionshouldnotoccurduring
normaluse.Tore-settheswitch:
• Isolatethemachinefromthemainsupply.
• Safelysupportthemachine-toaccesstheunderside.
• Usingacross-headscrewdriver,openthecoverplate.
• Usingasuitabletool,insertthetoolthroughtheapertureandpressthe
metalswitchuntilitsnapsclosed.Theswitchwillclosecorrectly,onlyifthe
machineiscoolenough.
• Replacethecoverplateandscrews.
• Power-onthemachine.
TROUBLESHOOTING
Problem
Possible cause
Solution
NopoweronLED
Machineisnotswitchedon
Switchonmachineatrearnexttopluginletandatthewallsocket
Readylightdoesnotcomeonaftera
longperiod
Machineisinahotorhumidarea
Movethemachinetoacooleranddryarea
Itemmaybetoothicktolaminate
Passthroughthemachineagain
Temperaturesettingmaybeincorrect
Checkpouchthicknessiscorrectlyselectedandpassthroughagain
Pouchhaswavesorbubbles
Temperaturesettingmaybeincorrect
Checkpouchthicknessiscorrectlyselectedandpassthroughagain
Pouchislostinthemachine
Pouchisjammed
Pouchdoesnotcompletelysealtheitem
Pouchwasused‘openend’first
Pouchwasnotcenteredonentry
Jamming
Pouchwasnotstraightuponentry
Selectreversebuttonandpullouttheitembyhand.Checkcooling
plateiscorrectlypositioned.
Emptypouchwasused
Coolingplatenotfixedcorrectly
Pouchisdamagedafterlamination
Temperaturenotincreasing
Damagedrollersoradhesiveonrollers
Mainfusefailure
Powercordnotfittedcorrectly
Passcleaningsheetsthroughthemachinetotestandcleanrollers
Checkandreplace
Curledorburntlaminations
Toohot
Reducetemperatureorincreasespeed
Softorpoorlamination
Toocold
Increasetemperatureorreducespeed
Rollerstoocold(<60°c)
Waitforrollerstowarm-up
"STOP"buttonmaybepressed
Press"MOTOR"or"SPEED"button
Rollersnotrunning
Unstablelaminationtemperature
Rollerelectricbrushmaybebroken
CannotselectanyMode
Circuitboarderror
Rollersnotrunning&motorisrunning
Loosecircuitboltsongear
Excessivenoise
Gearswordordamaged
Masterfusekeepsfailing
Damagedcircuitboard
Contactserviceengineer