Instructions for the installer 5.3 Regulation for natural gas The hob has been inspected for G20 (2H) natural gas at a pressure of 20 mbar. To allow the unit to work with this type of gas, perform the same operations described in paragraph “5.2 Regulation for LPG”, but choose the nozzles and regulate the primary air for natural gas, as shown in the following table and in paragraph “5.5 Regulation of primary air”. After the regulations have been carried out, restore the seals with sealing wax or equivalent material. Rated heating Burner Natural gas – G20 20 mbar capacity Nozzle diameter Reduced flowrate 1/100 mm (W) Auxiliary (1) 1.05 73 380 Semirapid (2) 1.65 92 380 Rapid (3) 2.55 115 650 Rapid large (4) 3.1 126 750 Fish pan (7) 2.0 100 750 Ultra rapid (5) 3.3 130 1200 Double Internal 1.05 73 380 crown External 3.9 140 1200 (6) 5.4 Regulation for town gas To allow the unit to work with this type of gas, perform the same operations described in paragraph “5.2 Regulation for LPG”, but choose the nozzles and regulate the primary air for town gas, as shown in the following table and in paragraph “5.5 Regulation of primary air”. Attention! Only units with safety valves can be used with town gas G110. Rated heating Burner Town Gas 110 - 8 mbar capacity Nozzle diameter Reduced flowrate 1/100 mm (W) Auxiliary (1) 1.05 132 380 Semirapid (2) 1.65 165 380 Rapid (3) 2.55 210 650 Rapid large (4) 3.1 240 750 Fish pan (7) 2 190 750 Ultra rapid (5) 3.3 250 1200 1.05 132 380 Double crown Internal (6) External 3.9 290 1200 31