Download Dell (PERC) S100 Personal Computer User Manual

Transcript
A5_bk0.book Page 40 Thursday, February 10, 2011 8:34 PM
Table 5-2. Pre-Installation Procedures For The Controller Drivers (continued)
Procedure
4 Create a bootable
virtual disk
5 Check controller
options and the boot
list priority
Steps
See "Creating Virtual Disks" on page 51.
a At the PERC S100 Virtual Disk Management utility or
PERC S300 Virtual Disk Management utility, use the
arrow keys to select Controller Options. Press
<Enter>. Make sure that Toggle INT13 Boot
Support is ON. Press <Esc> to exit.
b At the Virtual Disks field, make sure the bootable
virtual disk created in Procedure 4, is the first virtual
disk listed.
If the bootable virtual disk is not the first virtual disk
listed, see "Swapping Two Virtual Disks" on page 55.
NOTE: If Non-Raid virtual disks are used (and appear in the
Virtual Disks list), the Swap Two Virtual Disks option
is enabled only if the system contains an initialized physical
disk.
c Select Continue to Boot and press <Enter>.
NOTE: If the next Procedure (6) is not applicable, continue
with one of the following procedures:
• "Installing the Controller Drivers During the Operating
System Installation: For Systems with a PERC S100
Adapter" on page 42
• "Installing the Controller Drivers During the Operating
System Installation: For Systems with a PERC S300
Adapter" on page 44
40
Installing the Drivers