Warning: If your appliance is not properly installed a house fire may result. For your safety, follow the
installation directions. Contact local building or fire officials about restrictions and installation inspection
requirements in your area. These authorities should be consulted to determine if there is a need to obtain a
permit.
PLEASE read this entire manual before installation and use of this pellet fuel-burning room heater. Failure to
follow these instructions could result in property damage, body injury, or even death.
Save these instructions.
Some surfaces become hot at higher feeding rates. To prevent potential burns, avoid contact with those areas.
This heating unit must serve as a supplementary heat source. An alternative heat source should be available in
the home if needed. The manufacturer cannot be responsible for additional heating costs associated with the
use of an alternative heat source.
It is highly recommended that the user buys this product from a retailer who can provide installation and
maintenance advices.
PROFESSIONAL INSTALLATION IS HIGHLY RECOMMENDED
This manual is available for free download on the manufacturer’s web site. It is a copyrighted
document. Re-sale is strictly prohibited. The manufacturer may update this manual from time
to time and cannot be responsible for problems, injuries, or damages arising out of the use of
information contained in any manual obtained from unauthorized sources.
Printed in Canada
Manufactured by:
STOVE BUILDER INTERNATIONAL INC.
250, de Copenhague, Saint-Augustin-de-Desmaures
(Quebec), Canada G3A 2H3
Tel: (418) 878-3040
Fax: (418) 878-3001
45433A
12-03-2013
INTRODUCTION
Thank you for purchasing the ECO-65 pellet stove. You are now prepared to burn pellet in
the most efficient, convenient way possible. To achieve the safest, most efficient and most
enjoyable performance from your stove, you must do three things: 1) Install it properly; 2)
Operate it correctly; and 3) Maintain it regularly. The purpose of this manual is to help you do
all three.
PLEASE read this entire manual before installation and use of this pellet fuel-burning
room heater. Failure to follow these instructions could result in property damage,
bodily injury or even death.
Keep this manual handy for future reference.
Your Drolet ECO-65 has been independently tested to ASTM E1509-04 Standard
Specification for Room Heaters, Pellet Fuel Burning Type, UL 1482-2010 and ULC-S627-00
Standard for Solid Fuel Room Heaters, Oregon Administrative Rules for Mobile Homes (81423-900 through 814-23-909) and Installation as a Stove Heater. This pellet stove, when
installed, must be electrically grounded in accordance with local codes, or in the absence of
local codes, with the National Electrical Code, ANSI/NFPA 70 and CSA-C22.1.
We recommend that our pellet hearth products be installed and serviced by professionals
who are certified in the United States by NFI (National Fireplace Institute®) or in Canada by
WETT (Wood Energy Technology Transfer) or in Quebec by APC (Association des
Professionnels du Chauffage).
The bottom-feed burner system of this appliance is designed and tested specifically for use
only with four different types of pellets: standard wood pellets, 100% bark pellets,
sawdust/hay mix pellets, and switch grass pellets. This appliance is designed for residential
installation according to current national and local building codes as a freestanding room
heater. It is also approved as a mobile home heater. An outside combustion air source is
mandatory.
The stove will not operate using natural draft or without a power source for the blower
systems and fuel feed system and must not be burned with any type of coal.
This stove is designed to provide the optimum proportions of fuel and air to the fire in order to
burn free of smoke and soot. Any blockage of the air supply to or from the stove will seriously
degrade its performance and will be evidenced by a smoking exhaust and a sooting window.
For best operation, the ash content of the pellet fuel should be less than 1% and the calorific
value approximately 8,200 BTU/LB. Others fuels with a high ash content will require a higher
levels of maintenance and cleaning.
This appliance has been developed and built for residential supplementary heat source.
Commercial and industrial use should be avoided.
CAUTION: THE
INFORMATION GIVEN ON THE CERTIFICATION LABEL AFFIXED TO THE APPLIANCE
ALWAYS OVERRIDES THE INFORMATION PUBLISHED, IN ANY OTHER MEDIA (OWNER’S
MANUAL, CATALOGUES, FLYERS, MAGAZINES AND/OR WEB SITES).
SAFETY PRECAUTIONS
x
DO NOT OPERATE YOUR STOVE IF
YOU SMELL SMOKE COMING FROM IT.
TURN IT OFF, MONITOR IT, AND CALL
YOUR DEALER.
x
NEVER
USE
GASOLINE,
GASOLINE-TYPE
LANTERN
FUEL,
KEROSENE,
CHARCOAL
LIGHTER
FLUID, GARBAGE, NAPHTA, ENGINE
OIL OR SIMILAR LIQUIDS TO START
OR “FRESHEN UP” A FIRE IN THIS
STOVE. KEEP ALL SUCH LIQUIDS
WELL AWAY FROM THE STOVE WHILE
IN USE.
x
NEVER BLOCK FREE AIRFLOW
THROUGH THE OPEN VENTS OF THE
STOVE.
x
NEVER TRY TO REPAIR OR
REPLACE ANY PART OF THE STOVE
UNLESS INSTRUCTIONS ARE GIVEN IN
THIS MANUAL. ALL OTHER WORK
SHOULD BE DONE BY A TRAINED
TECHNICIAN.
x
THE STOVE WILL NOT OPERATE
DURING A POWER OUTAGE. IF AN
OUTAGE DOES OCCUR, CHECK THE
STOVE FOR SMOKE SPILLAGE AND
OPEN A WINDOW IF ANY SMOKE
SPILLS INTO THE ROOM.
x
DISCONNECT THE POWER CORD
BEFORE
PERFORMING
ANY
MAINTENANCE OR REPAIRS ON THE
STOVE.
NOTE: TURNING THE STOVE “OFF”
DOES NOT DISCONNECT ALL POWER
FROM THE STOVE.
x
DO NOT UNPLUG THE STOVE IF
YOU SUSPECT A MALFUNCTION. TURN
THE STOVE OFF, PERIODICALLY
INSPECT IT, AND CALL YOUR DEALER.
x
CONTACT YOUR LOCAL BUILDING
OFFICIALS TO OBTAIN A PERMIT AND
INFORMATION ON ANY INSTALLATION
RESTRICTIONS
OR
INSPECTION
REQUIREMENTS IN YOUR AREA.
NOTIFY YOUR INSURANCE COMPANY
OF THIS STOVE AS WELL.
x
KEEP FOREIGN OBJECTS OUT OF
THE HOPPER.
x
DO NOT THROW THIS MANUAL
AWAY. THIS MANUAL HAS IMPORTANT
OPERATING
AND
MAINTENANCE
INSTRUCTIONS THAT YOU WILL NEED AT
A LATER TIME. ALWAYS FOLLOW THE
INSTRUCTIONS IN THIS MANUAL.
x
DO
NOT
PLACE
CLOTHING,
FURNITURES OR OTHER FLAMMABLE
ITEMS ON OR NEAR THE STOVE.
x
THE VIEWING DOOR MUST BE
CLOSED
AND
LATCHED
DURING
OPERATION.
x
DO NOT OPERATE THE STOVE IF THE
FLAME BECOMES DARK AND SOOTY OR
IF THE BURN POT OVERFILLS WITH
PELLETS. TURN THE STOVE OFF,
PERIODICALLY INSPECT IT, AND CALL
YOUR DEALER.
x
DO NOT TOUCH THE HOT SURFACES
OF THE HEATER. CONTACT WITH UNIT
MAY CAUSE SKIN BURNS. KEEP
CHILDREN AWAY FROM THE UNIT AND
EDUCATE ALL CHILDREN OF THE
DANGER OF A HIGH TEMPERATURE
STOVE. YOUNG CHILDREN SHOULD BE
SUPERVISED WHEN THEY ARE IN THE
SAME ROOM AS THE STOVE.
x
IT IS RECOMMENDED THAT THE
STOVE BE UNPLUGGED WHEN NOT IN
USE FOR EXTENDED PERIODS OF TIME
(I.E. DURING THE SUMMER MONTHS). IF
THE STOVE IS INSTALLED IN A ROOM
WITHOUT AIR CONDITIONING, OR IN AN
AREA WHERE DIRECT SUNLIGHT CAN
SHINE ON THE UNIT, IT IS POSSIBLE THIS
CAN CAUSE THE TEMPERATURE OF THE
STOVE TO RISE TO OPERATIONAL
LEVELS; ONE OF THE SENSORS COULD
THEN MAKE THE BLOWERS START ON
THEIR OWN.
x
THE EXHAUST SYSTEM MUST BE
COMPLETELY AIRTIGHT AND PROPERLY
INSTALLED. ALL VENT CONNECTOR
JOINTS
MUST
BE
SEALED
AND
FASTENED IN ACCORDANCE WITH THE
PELLET
PIPE
MANUFACTURER'S
INSTRUCTIONS TO ENSURE CONSISTENT
PERFORMANCE AND AVOID SMOKE AND
ASH SPILLAGE.
x
THIS UNIT MUST BE PROPERLY
INSTALLED
TO
PREVENT
THE
POSSIBILITY OF A HOUSE FIRE. THE
INSTRUCTIONS MUST BE STRICTLY
ADHERED
TO.
DO
NOT
USE
MAKESHIFT
METHODS
OR
COMPROMISE IN THE INSTALLATION.
x
ALLOW THE STOVE TO COOL
BEFORE
CARRYING
OUT
ANY
MAINTENANCE OR CLEANING. ASHES
MUST BE DISPOSED IN A METAL
CONTAINER WITH A TIGHT LID AND
PLACED ON A NON COMBUSTIBLE
SURFACE WELL AWAY FROM THE
HOME STRUCTURE.
x
THIS STOVE MUST BE CONNECTED
TO A STANDARD 120 V., 60 HZ
GROUNDED ELECTRICAL OUTLET. DO
NOT USE AN ADAPTER PLUG OR
SEVER THE GROUNDING PLUG. DO
NOT ROUTE THE ELECTRICAL CORD
UNDERNEATH, IN FRONT OF, OR OVER
THE STOVE.
x
THE EXHAUST SYSTEM SHOULD
BE CHECKED, AT LEAST TWICE A
YEAR FOR ANY BUILD UP OF SOOT OR
CREOSOTE.
x
YOUR STOVE REQUIRES PERIODIC
MAINTENANCE AND CLEANING. FAILURE
TO MAINTAIN YOUR STOVE MAY LEAD
TO SMOKE SPILLAGE IN YOUR HOME.
x
THIS APPLIANCE IS DESIGNED AND
TESTED SPECIFICALLY FOR USE ONLY
WITH FOUR DIFFERENT TYPES OF
PELLETS: STANDARD WOOD PELLETS,
100% BARK PELLETS, SAWDUST/HAY
MIX PELLETS, AND SWITCH GRASS
PELLETS. ANY OTHER TYPE OF FUEL
BURNED IN THIS HEATER WILL VOID THE
WARRANTY AND SAFETY LISTING.
x
THE STOVE MUST BE BOLTED TO
THE FLOOR, HAVE OUTSIDE AIR, AND
NOT BE INSTALLED IN A BEDROOM (PER
H.U.D. REQUIREMENTS). CHECK WITH
LOCAL BUILDING OFFICIALS.
x
STOVE BUILDER INTERNATIONAL
INC. GRANTS NO WARRANTY, IMPLIED
OR STATED, FOR THE INSTALLATION OR
MAINTENANCE OF YOUR STOVE, AND
ASSUMES NO RESPONSIBILITY OF ANY
CONSEQUENTIAL DAMAGE(S).
x
IT IS MANDATORY TO CONNECT
THIS STOVE TO A 4¨ FRESH AIR INLET
TO REDUCE THE RISK OF HOPPER
BURN BACK CAUSED BY NEGATIVE
PRESSURE.
REGISTER YOUR WARRANTY ONLINE
To receive full warranty coverage, you will need to show evidence of the
date you purchased your stove. Keep your sales invoice. We also
recommend that you register your warranty online at
http://www.drolet.ca/en/service-support/warranty-registration
Registering your warranty online will help us track rapidly the information
we need on your stove.
TABLE OF CONTENTS
SAFETY PRECAUTIONS ....................................................................................................................................... 3
1.
INSTALLATION ......................................................................................................................................... 6
1.1.
FEATURES ................................................................................................................................................ 6
1.2.
PREPARATION ......................................................................................................................................... 6
1.3.
CLEARANCES .......................................................................................................................................... 6
1.4.
COMBUSTION AIR SUPPLY .................................................................................................................... 8
1.5.
ANCHOR THE STOVE ............................................................................................................................ 10
1.6.
VENTING ................................................................................................................................................. 10
1.6.1. Equivalent Vent Length (EVL) ............................................................................................................... 11
1.6.2. Installation Configurations .................................................................................................................... 12
a)
b)
c)
d)
e)
Horizontally through wall ................................................................................................. 12
Vertically with new chimney system ................................................................................ 14
Vertically into existing chimney system........................................................................... 15
Vertically into existing masonry fireplace ........................................................................ 15
Installation through side of masonry chimney.................................................................. 16
2.
OPERATION ............................................................................................................................................ 17
2.1.
PROPER FUEL ........................................................................................................................................ 17
2.2.
WHERE TO STORE BAGS OF PELLETS .............................................................................................. 17
2.3.
PRE-START-UP CHECK ......................................................................................................................... 17
2.4.
BUILDING A FIRE ................................................................................................................................... 17
2.5.
LIGHTING PROCEDURE ........................................................................................................................ 18
2.6.
UNIT CONTROLS (See Figure 16) .......................................................................................................... 18
2.7.
OPENING DOOR ..................................................................................................................................... 19
2.8.
CONVECTION BLOWER (ROOM AIR FAN) .......................................................................................... 19
2.9.
IF THE STOVE RUNS OUT OF PELLETS.............................................................................................. 19
2.10. REFUELING ............................................................................................................................................. 20
2.11. SHUTDOWN PROCEDURE .................................................................................................................... 20
2.12. SAFETY FEATURES ............................................................................................................................... 20
2.13. OPERATING THE STOVE USING A THERMOSTAT ............................................................................ 20
2.13.1. Thermostat Installation .......................................................................................................................... 20
2.13.2. Thermostatic mode ................................................................................................................................ 21
2.14. OPERATING SAFETY PRECAUTIONS ................................................................................................. 22
3.
MAINTENANCE ....................................................................................................................................... 24
3.1.
CLEANING THE BURN POT AND THE AIR WASH INLET................................................................... 24
3.2.
MAINTENANCE OF THE COMBUSTION CHAMBER, HEAT EXCHANGERS AND BLOWER
HOUSING .............................................................................................................................................................. 25
3.3.
MAINTENANCE OF THE HEAT EXCHANGERS AND BLOWER HOUSING ....................................... 25
3.4.
VENTING SYSTEM MAINTENANCE ...................................................................................................... 26
3.4.1. Dealing with a Chimney Fire ................................................................................................................. 26
3.4.2. Soot and Flyash – Formation and need for removal .......................................................................... 26
3.5.
ASH REMOVAL ....................................................................................................................................... 27
3.5.1. ASH DISPOSAL AND USE OF AN ASH VACUUM ............................................................................... 27
3.6.
DOOR ADJUSTMENT ............................................................................................................................. 27
3.7.
DOOR GASKET MAINTENANCE ........................................................................................................... 28
3.8.
GLASS CARE .......................................................................................................................................... 28
3.9.
REMOVAL AND REPLACEMENT OF BROKEN DOOR GLASS .......................................................... 29
3.10. REMOVAL AND REPLACEMENT OF GASKETS ................................................................................. 31
3.11. RECOMMENDED MAINTENANCE SCHEDULE .................................................................................... 38
4.
TROUBLESHOOTING GUIDE ................................................................................................................ 39
5.
ELECTRICAL DIAGRAM ........................................................................................................................ 45
5.1.
FUSE ACCESS ........................................................................................................................................ 46
6.
REPLACEMENT PARTS ......................................................................................................................... 47
APPENDIX A ........................................................................................................................................................ 50
APPENDIX B ........................................................................................................................................................ 51
DROLET LIMITED LIFETIME WARRANTY......................................................................................................... 52
INSTALLATION
1.
1.1.
FEATURES
DROLET ECO-65 FREESTANDING PELLET STOVE
x
x
x
x
x
x
x
x
x
x
x
x
x
1.2.
Width: 24”
Height: 41”
Depth: 30”
Weight: 375 lbs.
Flue size: 4”
Hopper Capacity: Up to 125 lbs. (This can vary
depending on pellet size, length, and diameter)
EPA status: < 4.5 g/h.
Burn rate: 1.3 lbs to 7.9 lbs. per hour
BTU range: 10,500 to 65,000
Electrical consumption:
o 5 Amps lighting cycle
o 2.5 Amps. continuous duty
Control board fuses: Main: 7.5A-250V fastblow
o Convection blower: 5A-250V fastblow
o Combustion blower: 3A-250V fastblow
o Exhaust blower: 3A-250V fastblow
o Auger 1: 3A-250V fastblow
o Auger 2: 3A-250V fastblow
o Ignitor : 5A-250V fastblow
Electrical requirement: 120VAC 15A
Approved installations: mobile home, conventional
PREPARATION
Factory packaging must be removed, and some minor
assembly work is required prior to installation for handle and
door adjustment. Also, the stove must be leveled using
threaded legs.
1.3.
FIGURE 1
Back wall installation
FIGURE 2
Corner installation
CLEARANCES
The Drolet ECO-65 has been tested and listed for installation
in residential and mobile home. (refer to figure 1 to 3)
FLOOR PROTECTION: In the USA, the unit must be installed
on a non-combustible floor pad extending at least 6 inches
(155 mm) in front of the door opening and at least 6 inches
(155 mm) on each side of the door opening. In Canada, the
unit must be installed on a noncombustible floor pad extending
at least 18 inches (460 mm) in front of the door opening and at
least 8 inches (205 mm) at the back and on each side of the
unit. The floor pad must have a thickness of at least 0.015''
(0.38mm). NOTE: ceramic tile, or any tile, must be laid on a
continuous non combustible sheet to prevent the possibility of
embers falling through to the combustible floor if cracks or
separation should occur in the finished surface.
Clearances are measured from the sides, back or face (door
opening) (refer to fig. 4). For ceiling clearance refer to figure 4.
Clearances may only be reduced by means approved by
the regulatory authority.
Dooropening
FIGURE 3
Floor protection
DO NOT USE MAKESHIFT MATERIALS OR COMPROMISES
IN THE INSTALLATION OF THIS UNIT.
INSTALL VENT WITH CLEARANCES SPECIFIED BY THE
VENT MANUFACTURER.
This heating unit must serve as a supplementary heat source.
An alternative heat source should be available in the home if
needed. The manufacturer cannot be responsible for additional
heating costs associated with the use of an alternative heat
source.
It is highly recommended that the user buys this product from a
retailer who can provide installation and maintenance advices.
We recommend leaving 24’’ on each sides of the appliance in order to
facilitate access for maintenance.
FIGURE 4
Celing clearance
FLOOR PROTECTOR
CLEARANCES TO COMBUSTIBLES
A
B
C
D
CANADA
USA
2’’ (55 mm)
6’’ (155 mm)
2’’ (55 mm)
3’’ (80 mm)
2’’ (55 mm)
6’’ (155 mm)
2’’ (55 mm)
3’’ (80 mm)
E
F
G
H
CANADA
USA
18’’ (460 mm)
N/A (USA only)
8’’ (205 mm)
8’’ (205 mm)
6’’ (155 mm)
6’’ (155 mm)
N/A (Canada only)
N/A (Canada only)
1.4.
COMBUSTION AIR SUPPLY
It is mandatory to connect this stove to an outside
combustion air source to reduce the risk of hopper
burn back caused by negative pressure. A insulated
4” inside diameter metallic pipe, either flexible or rigid,
must be attached to the inlet at the stove’s rear (refer
to figures 5, 6 & 7). A rodent guard (minimum ¼” wire
mesh) must be used at the terminus (refer to figure 6).
All connections must be secured and airtight by either
using the appropriately sized hose clamp and/or UL181-AP foil tape. Also make sure that the fresh air
damper is open while the stove is running. The fresh
air intake damper is located at the back of the stove
right hand side (refer to figure 6.).
For mobile home installations only:
x No combustion air supply may exceed 10 feet.
Sources of Outside Combustion Air:
x A hole in floor near the back of the leading onto a
ventilated crawl space under the house.
x A hole in the wall behind the stove.
FIGURE 5
Rear view
FIGURE 6.
The fresh air intake damper
FIGURE 7
FIGURE 8
Fresh air supply
Fresh air supply
1.5.
ANCHOR THE STOVE
The stove must be anchored to the floor with screws. Please use the two holes located on each side of the
pedestal. (See Fig. 9)
FIGURE 9
Anchor
1.6.
VENTING
In Canada, we recommend that you use a listed pellet vent that meets the ULC S-609-M89/ORD C441-M90
Standard.
For the United States, we recommend that you use a listed pellet vent that meets the UL-641Standard.
This unit can be vented in an existing factory-built or masonry chimney with the addition of a liner, provided the
chimney is more than 4” in diameter. The liner should be listed and should meet the ULC S-635/640 standard in
Canada and the UL-1777 standard in the USA. Refer to the instructions provided by the vent or chimney
manufacturer, especially when passing through a wall, ceiling, or roof.
Your venting system should have at least one foot of vertical rise for each foot of horizontal run. The
total vertical rise should never be less than 3 feet (see Appendix A).
This unit uses a pressurized exhaust system. All vent connector joints must be sealed and fastened. If vented
horizontally, joints should be made gastight. Please consult the pellet pipe manufacturer’s instruction to ensure
proper installation and consistent performance to avoid smoke and ash spillage.
DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE.
DO NOT INSTALL A FLUE DAMPER IN THE EXHAUST VENTING SYSTEM OF THIS UNIT.
WARNING:
INSTALL VENT AT CLEARANCES SPECIFIED BY THE VENT MANUFACTURER.
WARNING:
DO NOT INSTALL IN BEDROOM
CAUTION:
THE STRUCTURAL INTEGRITY OF THE MANUFACTURED HOME FLOOR, WALL, AND
CEILING/ROOF MUST BE MAINTAINED
CAUTION:
THE CHIMNEY CONNECTOR SHALL NOT PASS TROUGH AN ATTIC OR ROOF SPACE,
CLOSET OR SIMILAR CONCEALED SPACE, OR A FLOOR, OR CEILING.
1.6.1.
Equivalent Vent Length (EVL)
The longer the run of pipe in your installation, the
greater the restriction in your system.
x
x
x
Always use 4” pipe
Horizontal runs shall not exceed 9 feet.
Never exceed 30 feet of EVL.
To calculate EVL, use the following conversions
table:
Qty
Type of pipe
1
90° elbow or “T”
EVL equivalent(ft)
1
45° elbow
3
1 ft
Horizontal pipe run
1
1 ft
Vertical pipe run
5
0.5
Here is an example on how to calculate the EVL of
your installation. (See Figure 10):
(3 x 4’ of vertical length = 12’ x 0.5 = 6 EVL) +
(1 x elbow or "T" = 5 EVL) +
(2 x 1’ of horizontal length = 2 EVL)
Total EVL = (6 + 5 +2) = 13.
Note: Do not include the exterior wall termination (swan neck) in the
calculation of the EVL.
FIGURE 10
Venting through wall
1.6.2.
Installation Configurations
a) Horizontally through wall
(Refer to figures 10, 11, or 12)
NOTE: Follow vent chimney manufacturer’s instructions.
1. Position stove, adhering to clearances shown in Figures 1 & 2.
2. Locate position of hole in wall; directly behind stove exhaust vent (refer to figure 5).
3. Always maintain 3” clearance from combustible materials.
4. Install Vent wall thimble per Vent manufacturer’s instructions.
5. Attach enough piping to penetrate and extend at least 6 inches beyond the exterior wall. There should
always be at least one foot of vertical rise for each foot of horizontal run (see Appendix A). At least 3 feet of
vertical rise are needed in all cases. A longer vertical rise will favour a better exhaust.
FIGURE 11
Venting through wall
6. To reduce the risk of smoke spillage, never terminate with a horizontal run. If your system terminates with a
horizontal run, add at least 3 feet of vertical rise (see Appendix A).
7. Attach cap and seal outside wall thimbles with non-hardening waterproof mastic.
Termination should not be located so that hot exhaust gases can be a hazard to children. Exhaust gases can
reach temperatures of 500ºF and cause serious burns if touched.
Do not locate terminations:
In Canada:
a)
b)
c)
d)
less than 7 feet vertically above any public sidewalk, lane, street, right-of-way, stairway or landing;
within 6 feet of a mechanical air supply inlet to a building;
within 3 feet of a building opening or air inlet of another appliance;
above a gas meter/regulator assembly within 3 feet horizontally of the vertical centerline of the
regulator
e) within 6 feet of any gas service regulator vent outlet or within 3 feet of an oil tank vent or an oil tank
fill inlet;
f) less than 1 feet above adjacent grade level or any adjacent surface that may support snow, ice, or
debris;
g) within 3 feet of the property boundary; and
h) underneath a veranda, porch, or deck.
i) A clear space of at least 3 feet shall be provided from the termination to any building projection,
adjacent wall, or any combustible materials such as trees, shrubs, fencing, etc.
In the US:
a) less than 3 feet above any forced air inlet located within 10 feet;
b) less than 4 feet below or horizontally from, or one foot above, any door, window or gravity air inlet into
any building;
c) less than two feet from an adjacent building and not less than 7 feet above grade when located
adjacent to a public walkway. Mobile home installations must use a spark arrester. Other restrictions
may apply, such as the need to maintain a minimum distance to a gas meter. See NFPA 211.
FIGURE 12
Venting through wall
Basement installation
b) Vertically with new chimney system
(Refer to Figure 13)
OPTION: To achieve a centered vertical installation, a 45º elbow and a clean-out tee can be used to offset the
pipe from the exhaust outlet to the rear center of the stove.
OPTION: Install Vent elbow in place of clean-out tee. Locate stove. Drop plumb bob to center of tee outlet, mark
point on ceiling. Install ceiling support and Vent pipe per Vent manufacturer’s instructions.
1. Always maintain 3” clearance from combustible materials. When passing through additional floors or
ceilings, always install firestop spacer.
2. After lining up for hole in roof, cut either a round or square hole in roof, always 3” larger all the way around
pipe. Install upper edge and sides of flashing under roofing materials, nail to the roof along upper edge. Do
not nail lower edge. Seal nail heads with flexible waterproof sealant.
3.
Apply flexible, waterproof sealant where the storm collar meets the vent. Slide storm collar down until it sits
on the flashing. Seal and install cap. Mobile home installations must use a spark arrester.
FIGURE 13
Venting through roof
c) Vertically into existing chimney system
(Refer to Figure 14)
As an alternative, 4” Vent can be run inside existing chimney to termination (Figure 12). This is the preferred
method.
Follow guidelines for equivalent vent length.
FIGURE 14
Venting through
existing chimney
d) Vertically into existing masonry fireplace
(Refer to figure 15)
NOTE: Follow
instructions.
Vent
chimney
manufacturer’s
1. Have the masonry chimney inspected by a
qualified chimney sweep or installer to determine
its structural condition.
2. You will need a pipe length equal to the chimney
height from the hearth. If outside combustion air is
to be used, you will need a pipe length equal to
the chimney height plus 18 inches.
3. Install a blanking plate and the chimney pipe, and
if used the outside air pipe, as shown in Figure 13.
4. Attach the adapter, a section of pipe and cleanout
tee, making sure the cleanout tee is centered in
the chimney flue area. Use RTV, metallic tape,
and a minimum of three self-taping screws at all
joint connections to ensure a tight seal.
5. Position the stove, adhering to the clearances in
Figures 1 & 2.
Figure 15
Venting through masonry
chimney
6. Measure and build chimney top plate. Cut out holes for chimney pipe, and if used the outside air pipe. Install
and seal with non-hardening mastic to prevent water leakage. Install vent cap.
e) Installation through side of masonry chimney
(Refer to figure 16)
1. Position the stove, adhering to the clearances in Figures 1 & 2. Mark the center of the hole where the pipe is
to pierce the masonry chimney.
2. It will be necessary to break out the masonry around the location of the pipe center mark. Use a 5-inch
diameter hole for 4-inch pipe.
3. Measure and build chimney top plate. Cut out holes for chimney and the outside air pipe.
4. Install the tee on the bottom of the vertical pipe system and lower it down the chimney until the center
branch of the tee is level with the center of the hole in the masonry, as shown in Figure 16.
5. Install and seal the top plate from step 3 with non-hardening mastic. Slip the storm collar over the pipe, and
while holding the pipe at the proper elevation, affix the collar with a minimum of three ¼” stainless steel
sheet metal screws. Seal all joints and seams around the collar.
6. Connect the horizontal pipe by pushing it through the hole in the masonry and lining it up with the branch in
the tee. Push the pipe into the tee while twisting it to lock it into the tee.
7. If desired, once the horizontal pipe is in place, the space between the pipe and masonry may be filled with
high-temperature grout.
Install the trim collar. An adjustable pipe length and adapter may be needed to finish the connection to the
stove.
Figure 16
Venting through side of
masonry chimney
2.
OPERATION
2.1.
PROPER FUEL
THIS STOVE IS APPROVED FOR BURNING four different types of pellets: standard wood pellets, 100%
bark pellets, sawdust/hay mix pellets, and switch grass pellets! Each type of pellet has its properties
and will burn differently.
The ash produced can also vary greatly. Factory-approved pellets are those ¼” or 5/16” in diameter and not
over 1” long. Longer or thicker pellets sometimes bridge the auger flights, which prevents proper pellet feed.
Burning other types of pellets is not permitted. It will violate the building codes for which the stove has
been approved and will void all warranties. The different types of pellets that have been tested in the Drolet
Eco-65 were made of the following types of biomass:
Wood pellets
Wood pellets, whether made of hard or soft wood, are easy to burn. The pellets used are the same type as the
ones used in most pellet stoves. They should produce a fairly small amount of ash.
Wood and hay pellets
Pellets made of wood and hay will produce more ash than straight wood pellets. The wood and hay pellets that
have been tested in your Eco-65 consisted of 1/3 hay and 2/3 wood. Make sure that any wood and hay pellets
you put in your Eco-65 respect that mix (+/- 10%).
Bark pellets
100% bark pellets produce a hard crust that will be pushed into the ash drawer. Their ash content is very high.
If you burn 100% bark pellets, make sure that the crust forming in front of the burn pot breaks and falls into the
ash drawer. Ignition may be a bit more difficult and it is possible that the stove needs a second ignition cycle to
properly light the bark pellets.
Switch grass pellets
The ash content of switch grass pellets may vary depending on when this type of biomass is harvested. Switch
grass will burn very clean. A crust will form in front of the burn pot. It should break easily and fall into the ash
drawer. The crust is light and friable. It will occupy quite a bit of volume into the ash drawer. For this reason, it
is important to empty the ash drawer more frequently.
2.2.
WHERE TO STORE BAGS OF PELLETS
We recommend that you store your bags of pellets in a dry and well ventilated area if possible. Using dry pellets
will increase the performance of your stove. You may want to have a bag or two in the same room as your stove
for refuelling but make sure to respect the minimum clearances for combustible materials.
2.3.
PRE-START-UP CHECK
Remove burn pot, making sure it is clean and none of the air holes are plugged. Clean the firebox, and then
reinstall burn pot. Clean door glass if necessary (a dry cloth or paper towel is usually sufficient). Never use
abrasive cleaners on the glass or door. Check fuel in the hopper, and refill if necessary. Make sure that the
fresh air inlet damper is open.
2.4.
BUILDING A FIRE
Never use a grate or other means of supporting the fuel. Use only the Drolet approved burn pot.
NOTE: During the first few fires, your stove will emit an odor and a small amount of fumes as the high
temperature paint cures or becomes seasoned to the metal. Maintaining smaller fires will minimize this. Avoid
placing items on stovetop during this period because paint could be affected. Make sure the room is wellventilated. Open windows. Odors and fumes released during this process are unpleasant but they are
not toxic.
2.5.
LIGHTING PROCEDURE
a. Fill hopper and clean burn pot.
b. Press “MODE” button to select the desired setting “MANUAL” or “THERMOSTAT”
c. Adjust feed rate to desired setting by pressing “-” or “+” button.
If fire doesn’t start in 35 minutes, a warning code
details.
2.6.
will appear. Refer to troubleshooting section for more
UNIT CONTROLS (See Figure 16)
The blowers and automatic fuel supply are controlled from a panel on the right-hand side of the ECO-65. The
control panel functions are as follows.
a.
MODE SWITCH
x
When the mode switch is pressed, you will be able
to choose the Manual or the Thermostat mode, or
to turn off the appliance. If the Manual mode is
selected, the stove will automatically ignite. At this
time, the heat level must be selected manually to
adjust the stove’s heat output to the desired level.
If the thermostat mode is selected, the stove will
automatically modulate between the lowest heat
level and the heat level selected to keep the room
temperature at the thermostat’s setting. If the set
room temperature is achieved while the stove has
been running at the lowest heat level for more
than 45 minutes, the unit will automatically shut off
and will start another ignition cycle only when the
thermostat calls for heat again. No fire starter is
necessary to ignite the unit. The auger will feed
fuel and the electronic igniter will start. If the unit
doesn’t ignite within 12 minutes, the stove will start
another ignition cycle. If ignition fails a second
time, a warning message will appear on the
control panel.
x
The Heat Level may be selected during the
ignition cycle. However, the unit will only feed fuel
at the desired heat level setting when the heat
sensor located into the stove will receive a signal
indicating that the unit has been fully ignited. This
may take anywhere between 10 and 15 minutes.
b.
FUEL FEED SWITCH
x
When the “Fuel Feed” button is pushed the stove
will feed pellets continuously into the burn pot
during 1 minute.
CAUTION: THIS FUNCTION CAN ONLY BE
OPERATED WHEN THE STOVE IS IN “OFF”
POSITION. THE FUEL FEED SWITCH IS USED TO
PRIME THE AUGER WHEN AUGER IS EMPTY.
FIGURE 17
PC board
c.
CONVECTION BLOWER SPEED CONTROL
x
The convection blower speed varies directly with the fuel feed rate. Reducing the blower speed will also
reduce the noise.
When the “CONVECTION BLOWER SPEED CONTROL” button is pushed, the convection blower will
switch to its lowest speed. The convection blower will remain at its lowest speed unless the stove reaches a
certain temperature. If this occurs, the convection blower will go back to its highest setting to cool down the
stove. The “CONVECTION BLOWER SPEED CONTROL” will have to be pushed again for the convection
blower to go back to its lowest speed.
x
d.
HEAT LEVEL
x
By pressing “+” or “-”, you can set the pellet feed rate and hence the heat output of your stove. The levels of
heat output will incrementally change and each LED indicates the level from 1 to 6.
e.
RESET
Reset button has to be used to clear most warnings on the control and restart your stove.
2.7.
OPENING DOOR
The door should be open only for maintenance purposes.
2.8.
CONVECTION BLOWER (ROOM AIR FAN)
Upon starting your stove, the convection blower will not come on until the stove’s heat exchanger warms up.
This usually takes about 10 to 15 minutes from start-up. Speed will vary with the selected feed rate, except if the
“CONVECTION BLOWER SPEED CONTROL” mode has been activated.
2.9.
IF THE STOVE RUNS OUT OF PELLETS
If the stove runs out of pellets, the fire goes out and the auger motors and blowers will run until the stove cools
down. This will take a few minutes.
After the stove’s components stop running, a warning message will appear
.
To restart, press the “RESET” button, refill the hopper, and press the “FUEL FEED” button
until pellets
begin to fall into the burn pot. Press the “MODE” button to start the unit on Manual or Thermostatic mode.
2.10.
REFUELING
We recommend that you do not let the hopper drop below ¼ full. If the reload lid stays open for more than
3 minutes, a warning
will appear. To restart, press the “RESET” button, and then press the “MODE” button
to start the unit on Manual or Thermostatic mode.
KEEP HOPPER LID CLOSED AT ALL TIMES EXCEPT WHEN REFILLING. THE HOPPER MAY BE FILLED
WHILE THE STOVE IS OPERATING. DO NOT OVERFILL HOPPER.
2.11.
SHUTDOWN PROCEDURE
Turning your Drolet stove off is a matter of pressing the “MODE” control panel switch, until the “OFF” led goes
on. The blowers will continue to operate until internal firebox temperatures has fallen to a preset level.
2.12.
SAFETY FEATURES
a. If the exhaust blower fails, the flue is blocked or a back draft occurred inside the flue, an air pressure switch
will automatically shut down the auger and the combustion blower. Then, a warning message
will
appear. This safety feature is to prevent the unit from burning fuel when the exhaust blower has failed,
therefore preventing combustion fumes from spilling into the room.
b. If the temperature in the auger rises beyond a certain acceptable level, a high temperature switch located on
the auger housing will stop the fuel feed system and a warning
CODE
H
BEFORE RESETING
Heat exchanger and/or exhaust system
is/are clogged. Refer to the owner’s
manual for maintenance procedures.
will appear.
TO RESET
Press simultaneously for 2 seconds the mode
and reset.
*** After 3 attempts, reset is no longer possible, call SBI technical support.
2.13.
OPERATING THE STOVE USING A THERMOSTAT
A thermostat may help you maintain a constant house temperature automatically. A Low voltage thermostat is
required. A fixed wall mount or hand held model can be used. The control panel can be set up three ways to
operate your stove in thermostatic mode.
2.13.1. Thermostat Installation
x
x
Unplug the stove from the power outlet.
Connect two thermostat wires to the terminal block located on the lower right side of the back of the stove.
To do so, loosen the two screws and insert the wires in the terminals. Tighten the two screws. (See
figure 18)
x
If you are using a wireless wall thermostat or a
hand held thermostatic remote control, you can
locate the receiver behind the stove’s back panel,
on the right end side, just below the terminal
block. Most receivers are already equipped with
quick-connect terminals. Simply unplug the PC
board wires connected to the back of the terminal
block and connect them directly with the receiver’s
terminals. Location of the thermostat is very
important to obtain the best comfort and efficiency
from your ECO-65. The thermostat should be
mounted 50 inches from the floor on a wall
located 15 to 20 feet from the stove. You should
avoid an installation directly in front of the stove to
avoid cycling.(See figure 19)
FIGURE 18
Rear view
FIGURE 19
Thermostat location
2.13.2. Thermostatic mode
x
To use this mode, the “MODE” button must be pushed to “Thermostat” upon starting the stove. The heat
setting is then selected using the “Heat Level” selector “+ or –”. When set in thermostatic mode, the stove
will automatically run at the heat level selected until the set room temperature is reached. When that occurs,
the stove will switch to heat setting #1 (lowest) until the thermostat calls for heat again. The convection
blower will also slow to its lowest speed. When the thermostat calls for heat again, the stove will increase its
feed rate to match the heat setting selected.
N.B.: If the room temperature remains stable and the thermostat does not call for heat during at least
45 minutes, the stove will shut down. When the thermostat calls for heat again, the stove will start an ignition
cycle. Once the ignition cycle is completed, the stove will increase its feed rate to match the heat setting
selected.
N.B.: It is possible to change the setting of your unit such that if the thermostat does not call for heat after 45
minutes, the unit will remain at the lowest heat setting (#1) but will not shut down (this is the PILOT ON mode).
The stove will remain at the lowest heat level until the thermostat calls for heat again. It is also possible that the
unit shuts down as soon as the thermostat stops calling for heat. This mode is called “PILOT OFF”.
If you
prefer that your unit runs following one of these logics, you need to change the setting to PILOT ON or PILOT
OFF by simultaneously pressing the following two buttons on the PC Board for a couple of seconds:
and
Once you do that, the letters P, I, L, O, T, O, N will appear on the PC Board to let you know that you are in
the “PILOT ON” mode. By pressing again the two buttons, the letters P, I, L, O, T, O,F,F will appear on the
PC Board to let you know that you are in the “PILOT OFF” mode. If you wish to go back to the default
thermostatic mode (i.e. the unit shuts down after 45 minutes if the thermostat does not call for heat), simply
press the same two buttons again for a couple of seconds. The letters P, I, L, O, T, A, U, T, O will appear on
the PC Board to let you know that you are in the “PILOT AUTO” mode.
NOTE: When in thermostatic mode:
YOU SHOULD NOT OPERATE THE MANUAL CONTROL OR PLAY WITH THE TEMPERATURE
SETTING.
YOUR THERMOSTAT SHOULD BE INSTALLED BY AN AUTHORIZED DEALER OR SERVICE
PERSON.
2.14.
OPERATING SAFETY PRECAUTIONS
PLEASE READ THIS!
a. If you notice a smoldering fire (burnpot full but no visible flame) AND a heavy smoke buildup in the
firebox, immediately TURN OFF the stove, but DO NOT unplug it. Do not open the door. Make sure
that the fresh air damper is open and do not tamper with any controls on the stove. Wait until smoke
inside the firebox clears and blowers shut down. Do as instructed in “PRE-START-UP CHECK” and
“LIGHTHING PROCEDURE”, then attempt to restart the fire. If the problem persists, contact your dealer.
Please note that smoke build-up during ignition may occur. Smoke can accumulate in the firebox for a few
seconds just before the igniter is hot enough to fire-up the pellets in the burn pot. This is normal. As soon
as there is fire in the burn pot, smoke will disappear.
b.
DO NOT STORE OR USE FLAMMABLE LIQUIDS, ESPECIALLY GASOLINE, IN THE VICINITY OF
YOUR ENERZONE STOVE. NEVER USE A GAS OR PROPANE TORCH, GASOLINE, GASOLINE-TYPE
LANTERN FUEL, KEROSENE, CHARCOAL LIGHTER FLUID OR SIMILAR FLUIDS TO START OR
“FRESHEN UP” A FIRE IN THIS HEATER.
c.
WARNING: DO NOT OVERFIRE THIS STOVE. This may cause serious damage to your stove and void
your warranty. It also may create a fire hazard in your home. IF ANY EXTERNAL PART OF THE UNIT
BEGINS TO GLOW, YOU ARE OVERFIRING. Immediately press the “MODE” switch on the control panel,
until reaching the ‘OFF’ position. DO NOT UNPLUG YOUR STOVE. If you leave your house and your
stove is not connected to a thermostat or a fresh air supply, do not leave it at the maximum setting. If the
ambient air in a confined room becomes too hot, the stove may overheat and the thermal protection
on the combustion motor, exhaust motor or auger motor may be activated. This will cause one of
the motors to stop and a warning code may appear. Also, the thermistor may reach its maximum
limit. If this happens, the stove will automatically reduce the feeding rate until the thermistor
temperature has decreased.
d. KEEP ALL LOOSE OR MOVEABLE HOUSEHOLD COMBUSTIBLES, SUCH AS FURNITURE, DRAPES,
TOYS, ETC. AT LEAST THREE FEET FROM THE OPERATING STOVE.
e. Maintain proper ventilation. It is important that adequate oxygen be supplied to the fire for the combustion
process. During the winter season, make sure that the fresh air intake is free of any ice as this will starve
the fire of air and prevent the proper operation of the stove. YOUR STOVE HAS TO BE CONNECTED TO
A 4” FRESH AIR KIT. Make sure that the fresh air intake damper is always fully open when the stove
is burning.
f.
The stove exhaust fan produces a negative pressure in the room. It draws air from the inside to the outside.
In the same way, other appliances can also create a bigger negative pressure. In this case, as the air
naturally flows from high pressure point to low pressure point, the bigger negative pressure may draw the
smoke from the inside of the stove into the room. The stove can also affect other ventilation appliances,
causing the same effect to them.
g. Not following the instructions contents of his manual may cause smoke spillage into the room and other
potential hazards. It is always recommended to install strategically placed smoke detectors and to have a
fire extinguisher in a convenient location.
h. Do not open the stove door when operating unless necessary. This will create a dirty, inefficient burn and
could allow smoke spillage or sparks to escape.
i.
Do not open the ash drawer access panel when operating unless necessary. This will create a dirty,
inefficient burn and could allow smoke spillage or sparks to escape.
j.
Do not permit operation by young children or those unfamiliar with stove’s operation.
k.
Do not service or clean this appliance without disconnecting the power cord.
l.
If the stove is installed in a room without air conditioning, or in an area where direct sunlight can shine on
the unit, it is possible this can cause the temperature of the stove to rise to operational levels; one of the
sensors could then make the blowers start on their own. It is recommended that the stove be unplugged
when not in use for extended periods of time (i.e. during the summer months).
m. Burning any solid fuels generates carbon monoxide in low concentration. This gas is evacuated by the
exhaust venting system. In higher concentrations, carbon monoxide is toxic and may cause death. To
prevent this, ensure that your venting system is gastight.
n. Use only approved fuels in this stove. Other fuels may be highly volatile; embers could enter the exhaust
venting system causing a hazardous situation.
3.
MAINTENANCE
FAILURE TO CLEAN AND MAINTAIN THIS UNIT AS INDICATED CAN RESULT IN POOR PERFORMANCE
AND SAFETY HAZARDS. NEVER CLEAN WHEN HOT.
WARNING : THE USE OF A DOMESTIC, CENTRAL OR COMMERCIAL VACUUM CLEANER TO
PERFORM THE MAINTENANCE OF YOUR PELLET STOVE IS NOT RECOMMENDED. ASH
PARTICLES ARE SO FINE THAT IT CAN DAMAGE THE MOTOR OF SUCH VACUUM
CLEANERS. MOREOVER, EMBERS THAT ARE STILL HOT MAY CATCH FIRE IN THE USE
OF AN ASH VACUUM. THE MODEL CHEETAH II (AC02580) ASH VACCUM IS SPECIALLY
DESIGNED FOR THIS USE AND IS HIGHLY RECOMMENDED.
3.1.
CLEANING THE BURN POT AND THE AIR WASH INLET
The burn pot should be kept clean and its ports should not be clogged with combustion residues. Cleaning the
burn pot is simple. To do so, you may use a scraper, a brush or release the clip in front of the burn pot. Then,
remove the burn pot by lifting and pulling it out. Once the burn pot is removed you should clean thoroughly
under the burn pot mount with an ash vacuum to remove ashes that may have accumulated.
Once the burn pot is clean, vacuum the ashes that may have accumulated in the air wash inlet slot (A) between
the bottom glass retainer and the glass. This will allow an optimum air flow along the inside portion of the glass
and prevents the glass from sooting-up.
FIGURE 20
Burn Pot
NOTE: Inspect burn pot periodically to see that holes have not become plugged. If so, clean thoroughly.
3.2.
MAINTENANCE OF THE COMBUSTION CHAMBER, HEAT EXCHANGERS AND BLOWER
HOUSING
Remove and clean the baffle inside the combustion chamber after burning +/- 10 bags of pellets.
3.3.
MAINTENANCE OF THE HEAT EXCHANGERS AND BLOWER HOUSING
The heat exchangers should be inspected regularly during the heating season. Easy access is provided:
To access the heat exchangers, remove the decorative panel and the air jacket access panel located on the left
hand side of the stove. Then, remove the three cleanout trap to perform the maintenance. It is important to start
from the top and finish at the bottom. Use a scraper and an ash vacuum to clean the heat exchanger. The use
of an ash vac is the most efficient way to collect ashes that have accumulated. Please note that you do not need
to repeat the same steps on the right side of the appliance. The right hand side needs to be opened and
cleaned only if there is excessive ash accumulation. Exhausted combustion product may also accumulate within
the exhaust fan housing and block the pressure switch tap located on the blower’s cleanout panel. Disconnect
the pressure switch hose and remove the blower’s cleanout panel. Then use a mesh or wire brush to clean the
tap then blow in the pressure switch hose to make sure it is free of any obstruction. Clean and vacuum any
build-up in the exhaust blower housing being very careful not to damage the impellers while cleaning each
blades. Should one of the cleanout panel gaskets be damaged, it is very important that you replace it in order to
prevent leakage of flue gases and soot.
FIGURE 21
Cleanout trap
and Pressure
tap location
3.4.
VENTING SYSTEM MAINTENANCE
REGULARLY EXAMINE THE FLUE PIPES, THE JOINTS, AND THE SEALING TRIMS TO ENSURE
THAT THE SMOKE AND THE COMBUSTION GASES ARE NOT TRANSPORTED INTO THE AIR
DUCTING SYSTEM.
The most efficient method to sweep the venting system is by using a 4-inch pellet brush. Brush downwards so
ash, soot and creosote residues will come off the inner surface and fall at the bottom of the venting system
where they can be removed easily. The chimney must be in good condition and kept clean.
If a significant layer of creosote has accumulated (3mm / 1/8” or more), it must be removed immediately
to eliminate the risk of a chimney fire.
3.4.1. Dealing with a Chimney Fire
Regular chimney maintenance and inspection can prevent chimney fires. If you have a chimney fire, follow
these steps:
1. Immediately turn off the stove;
2. Alert your family of the possible danger;
3. If you require assistance, alert your fire department;
4. If possible, use a dry chemical fire extinguisher, baking soda or sand to control the fire. Do not use
water as it may cause a dangerous steam explosion;
5. Check outside to ensure that sparks and hot embers coming out of the chimney are not igniting the
roof;
6. Do not use the stove again until your chimney and stove have been inspected by a qualified chimney
sweep or a Fire Department Inspector;
CAUTION:
CLEANOUT OF THE HEAT EXCHANGER, FLUE PIPE, AND CHIMNEY, IS ESPECIALLY
IMPORTANT AT THE END OF THE HEATING SEASON TO MINIMIZE CORROSION DURING
THE SUMMER MONTHS, CAUSED BY ACCUMULATED ASH.
3.4.2. Soot and Flyash – Formation and need for removal
The products of combustion will contain small particles of flyash. The flyash will collect in the exhaust venting
system and restrict the flow of the flue gases. Incomplete combustion, such as occurs during startup, shutdown,
or incorrect operation of the room heater will lead to some soot formation which will collect in the exhaust
venting system. The exhaust venting system should be inspected at least once a year to determine if cleaning is
necessary.
3.5.
ASH REMOVAL
In order to remove ashes form the ash drawer, simply unscrew the wing nut, open the access door, and empty
the ash drawer.
Attention, it is important that the ash drawer is in place and the access door is kept closed
while the appliance is in use.
FIGURE 22
Ash Drawer
3.5.1. ASH DISPOSAL AND USE OF AN ASH VACUUM
Ashes must be placed in a metal container with a tight fitting lid. The closed container should be placed on a
non-combustible floor or on the ground, well away from all combustible materials, pending final disposal. This
container should not receive any other type of waste. If the ashes are disposed of by burial in soil or otherwise
locally dispersed, they should be retained in the closed container until all cinders have been thoroughly cooled.
Once the ashes have been removed, you should take this opportunity to thoroughly vacuum around the ash
drawer with an ash vacuum.
3.6.
DOOR ADJUSTMENT
In order for your stove to operate properly, the door should be adjusted periodically to provide an air tight fit. To adjust:
• Remove the lock pin (spring pin) by pulling and turning it using pliers ("wise grip")
• Turn the handle counter clock wise one turn to increase pressure
• Re-install the lock pin (spring pin) with a small hammer
FIGURE 23
FIGURE 24
3.7.
DOOR GASKET MAINTENANCE
It is important to maintain the door gasket in good condition. After a while, the gasket might sag; a door
adjustment may then be required. If the door adjustment is not sufficient, replace the door gasket with a genuine
one. If the appliance door is not properly sealed, combustion gases may be dispersed into the room.
3.8.
GLASS CARE
Clean door glass as necessary. The use of a specialty designed cleaner is recommended. Your authorized
Drolet dealer can also assist you to choose the right product. Regular household glass cleaners will not clean
creosote.
WARNING: NEVER USE ABRASIVE CLEANERS ON THE GLASS OR DOOR.
WARNING: DO NOT CLEAN THE GLASS WHILE IT’S HOT.
WARNING: DO NOT ABUSE THE DOOR GLASS BY STRIKING, SLAMMING OR SIMILAR TRAUMA.
WARNING: DO NOT OPERATE THE STOVE WITH THE GLASS REMOVED, CRACKED OR BROKEN.
3.9.
REMOVAL AND REPLACEMENT OF BROKEN DOOR GLASS
WARNING: ALWAYS WEAR SUITABLE GLOVES WHILE HANDLING BROKEN GLASS.
Carefully remove any loose pieces of glass from the doorframe. Dispose of all broken glass properly.
A broken glass must be replaced with an identical ROBAX (ceramic glass) 5 mm thick with the dimensions :
10’’5/32 x 14’’21/32. Your authorized Drolet dealer can help you to obtain this genuine replacement part.
To replace the glass, use the following procedure;
1. Put the door assembly face down on a clean and non abrasive surface (towel, bubble wrap, etc.) to
avoid damaging the door.
2. Remove the screws and the 2 glass retainers.
3. Remove the remaining broken glass.
4. Remove the inner door frame adhesive gasket if necessary.
5. To install the new glass, follow the above steps in reverse order.
6. If the old gasket was removed, install a new inner door frame adhesive gasket #40018 as shown in the
following figures.
In the handle area, apply the gasket in surrounding the cast iron extrusion to ensure an adequate airtightness.
Cut the gasket using cutting pliers.
7. Install 4 x ½ inch pieces of #40018 adhesive gasket aligned with each retainer tab to keep the
appropriate gap between the glass and the door frame.
8. Install the glass in the door frame making sure it is centered.
9. Set the torx of the power driver at 1/3 of its capacity. Install the retainers using the screws removed in
step 2. Start by installing one screw in the carter hole of each retainer, it will help you position the trims.
Make sure the glass does not move and remain centered before installing the other screws. Each
screw must be snuggled against the retainer not over tighten. Once the retainers are secured the tabs
should barely touch the glass …
WARNING: REPLACEMENT GLASS SHOULD ONLY BE PURCHASED FROM A DROLET DEALER (SEE
“REPLACEMENT PARTS’’ SECTION). TEMPERED GLASS OR ORDINARY GLASS WILL NOW
WITHSTAND THE HIGH TEMPERATURES OF THE ECO-65.
3.10.
REMOVAL AND REPLACEMENT OF GASKETS
Exhaust blower cleanout trap gasket
Step 1:
Slide the left side panel about 10" toward the front. In order to remove the side panel, align the rear bearing with
the circular opening in the sliding rail then pull it out.
Step 2:
Remove all 6 bolts securing the exhaust blower cleanout trap. Remove the worn gasket and clean-up the
contact surfaces. Keep the bolts for further instructions.
Step 3:
Remove all 4 bolts securing the cleanout plate located inside the exhaust blower cage assembly. Remove all
accumulation of soot within the housing using an ahs vacuum. Put back the cleanout plate and its respective
bolts in place.
Step 4:
Apply gasket #21344 from AC09190 on the exhaust blower cleanout trap and secure it all with all 6 bolts kept on
step 2.
Front left cleaning and replacing gasket
Step 1:
Remove the side air jacket access panel by untying the 9 spring clips.
Step 2:
Remove all 8 bolts securing the cleanout trap. Remove the worn gasket and clean-up the contact surfaces.
Clean-up the dirty area inside the appliance with an ash vacuum. Apply gasket #21352 from AC09190 on the
cleanout trap. Put back in place the cleanout trap with its respective bolts.
Step 3:
Remove all 5 bolts retaining the upper cleanout trap. Remove the worn gasket and clean-up the contact
surfaces. Clean-up the dirty area inside the appliance with an ash vacuum. Apply gasket #21348 from AC09190
on the cleanout trap. Put back in place the cleanout trap with its respective bolts.
Step 4:
Put back in place the side air jacket access panel and re-attach all 9 spring clips.
Step 5:
Put back in place the side panel by sitting down the bottom on the lower track first, and then push it to the
vertical. Align the rear bearing through the circular opening in the top sliding track and push the side panel
toward the back.
Right cleanout panel gasket
Step 1:
Slide the right side shield about 10" toward the front. Align the rear bearing through the circular opening in the
top sliding track in order to remove the side shield by pulling it back.
Step 2:
Remove the upper air jacket access panel by untying the 8 spring clips.
Step 3:
Remove all 6 bolts retaining the right cleanout panel. Remove the worn gasket and clean-up the contact
surfaces. Clean-up the dirty area inside the appliance with an ash vacuum. Apply gasket #21349 from AC09190
on the cleanout panel. Put back in place the cleanout panel with its respective bolts.
Step 4:
Put back in place the upper air jacket access panel and re-attach all 8 spring clips.
Step 5:
Put back in place the side panel by sitting down the bottom on the lower track first then pushes it to the vertical.
Align the rear bearing through the circular opening in the top sliding track and push the side shield toward the
back.
3.11.
RECOMMENDED MAINTENANCE SCHEDULE
Use this as a guide under average-use conditions.
Components
Baffle
Bottom air wash inlet
Burn Pot
Glass
Ash Drawer
Combustion Chamber
Heat Exchanger Tubes
Exhaust Channels
(through access traps)
Exhaust Blower
Combustion Blower
Pressure Switch Tap
Venting System
Gaskets
Hopper
Weekly
or after
+/- 500 pounds
Vacuum
Vacuum
Brush / Vacuum
Clean
Empty / Vacuum
Vacuum
Twice a year
or after
1.5 tons
Annually
or
per 3 tons of pellets
Vacuum / Brush*
Scrape and
Vacuum*
Vacuum*
Vacuum*
Vacuum*
Brush*
Inspect / Sweep*
Inspect
Sweep and Clean
Empty / Vacuum
*Cleaning frequency may vary depending on the type of fuel used. Fuel with higher ash content will increase
cleaning frequency.
4.
TROUBLESHOOTING GUIDE
When your stove acts up, your first reaction may be to call for help.This guide may save time and money by
enabling you to solve simple problems yourself. Problems can be caused by only five factors: 1) poor fuel; 2)
poor operation or maintenance; 3) poor installation; 4) component failure; 5) factory defect. You can usually
solve the problems related to 1 and 2. Your dealer can solve problems relating to 3, 4 and 5. Refer to figures 24
- 27 to help locate indicated parts.
Should you need to contact your dealer or the manufacturer, please photocopy and fill out the form in
Appendix B. Try to answer as many questions as you can. Have it handy when you call. This will help
you obtain a much faster service.
STOVE SHUTS OFF AND
APPEARS ON CONTROL BOARD
Possible Causes:
Possible Remedies: (Unplug stove first when possible)
1.
Airflow pressure switch hose or pressure tap for hose are
blocked.
Unhook air hose from the airflow switch and blow through it. If air
flows freely, the hose and tube are fine. If air will not flow through
the hose, use a thin wire to clear the blockage.
2.
The air inlet, burn pot, interior combustion air chambers,
combustion blower, or exhaust pipe are blocked with ash or
foreign material.
Follow all cleaning procedures in the maintenance section of the
owner’s manual.
3.
Vent pipe is incorrectly installed.
Check to make sure vent pipe installation meets the criteria in the
owner’s manual as well as the pipe manufacturer’s
recommendations.
4.
The airflow pressure switch wire connections are faulty.
Check the connectors attached to the pressure switch.
5.
The airflow pressure switch wires are pulled loose at the
connector on the wiring harness.
Check to see whether the wires are loose at the connectors.
6.
Exhaust blower failure.
This blower must turn on when you start the unit. If it does not, make
sure there is power on the connections. If the power is connected,
the motor is probably defective; if there is no power, see #7.
7.
Control board is not sending power to exhaust blower.
If there is no power going to the blower, check all connections. If all
wires are properly connected, you have a defective control board.
8.
Control board not sending power to airflow pressure switch.
There should be a 120-volt current going to the air switch after the
stove has been on. You will need a technician to perform this test.
9.
Airflow pressure switch has failed (very rare).
To test the airflow pressure switch, you need to disconnect the air
hose from the blower casing. With the other end still attached to the
switch, very gently suck on the loose end of the hose (you may want
to completely disconnect the hose from the stove and the switch first
and make sure it is clear). If you hear a click, the switch is working.
Be careful: too much suction can damage the switch.
STOVE SHUTS OFF AND DISPLAYS WARNING CODE
Possible Causes:
Possible Remedies: (Unplug stove first when possible)
1.
The hopper is out of pellets.
Refill the hopper.
2.
The burn pot holes are blocked.
Remove the burn pot and clean it thoroughly.
3.
The air inlet, interior chambers, or exhaust system is partly
blocked.
Follow all cleaning procedures in the maintenance section of the
owner’s manual.
4.
One of the two augers motor has failed.
Remove the auger motor from the auger shaft and try to run the
motor separately by pressing the fuel feed button on the control
board. Make sure that the hopper lid is not open. If the motor turns,
the shaft is jammed on something. If the motor does not turn, the
motor is defective or there is a faulty connection with the control
board. To remove the auger motor, take the rear louver off the stove
body. Loosen the two screws holding the motor to the auger shaft.
5.
One of the two auger shaft is jammed.
Remove the auger shaft from the auger housing. Start by emptying
the hopper. Take the rear louver off the stove body. Then take the
auger motor off by removing the screws that hold the motor to the
auger shaft. Once the motor is out, remove the four screws on the
steel plate that holds the auger shaft to the auger housing. Then
rotate the bottom end of the auger shaft down towards you until you
can pull the shaft down out of the stove. After you have removed the
shaft, inspect it for bent flights, burrs, or broken welds. Remove any
foreign material that may have caused the jam. Also, check the
auger housing for signs of damage such as burrs, rough spots, or
grooves cut into the metal that could have caused a jam. Clean the
auger housing thoroughly to remove all pellet dust.
6.
The thermistor heat sensor has malfunctioned.
The thermistor is a heat sensor located on the exhaust housing. Its
function is to tell the control board that the unit has ignited properly
by measuring the heat in the exhaust. The pellet stove will not start
feeding pellets at the desired heat setting until it has received a
signal from the thermistor heat sensor. If the thermistor heat sensor
is bad, the unit will stop after the ignition cycle. If this situation
occurs, call your dealer or technician.
STOVE FEEDS PELLETS, BUT WILL NOT IGNITE AND
APPEARS ON THE CONTROL BOARD
Possible Causes:
Possible Remedies:
1.
Blockage in igniter tube or inlet for igniter tube.
Remove the burn pot and clean it thoroughly. Make sure that all
openings are clear. Find the place where the igniter tube comes out
of the burn pot housing. It is a small tube located on the back of the
burn pot housing. Make sure it is clear. Make sure there is no debris
around the igniter element or inside the igniter tube.
2.
Defective igniter element.
Supply power directly to the igniter element. Watch the tip of the
igniter from the front of the stove. After about 30 seconds, the tip
should glow. If it does not, the element is defective and must be
replaced. You may need a technician to perform this test.
3.
The thermistor heat sensor has malfunctioned.
The thermistor is a heat sensor located on the exhaust housing. Its
function is to tell the control board that the unit has ignited properly
by measuring the heat in the exhaust. The pellet stove will not start
feeding pellets at the desired heat setting until it has received a
signal from the thermistor heat sensor. If the thermistor heat sensor
is bad, the unit will stop after the ignition cycle. If this situation
occurs, call your dealer or technician.
4.
The control board is not sending power to the igniter.
Check the voltage going to the igniter during ignition. It should be a
full current. If the voltage is lower than full current, check the wiring.
If the wiring is functional and properly connected, the board is
defective. You will need a technician to perform this test.
5.
The pump is not connected properly or isn’t working properly
Verify that the plug is connected properly and if the pump is running
during the lightning cycle. If the pump isn’t working make sure all
connections are good.
STOVE FEEDS PELLETS, BUT WILL NOT IGNITE AND
APPEARS ON THE CONTROL BOARD
Possible Cause:
Possible Remedy:
1.
The igniter or the pump is defective or the wiring harness shorted.
The igniter fuse on the control board has blown.
Remove the control board cover and check if the F1 fuse appears to
have blown. Replace it with a 5 Amp 250V fuse. Plug the stove
back on and try to start the unit.
STOVE FEEDS PELLETS, BUT WILL NOT IGNITE AND
APPEARS ON THE CONTROL BOARD
Possible Causes:
Possible Remedies:
1.
The auger jammed, the auger motor is defective or the
wiring harness shorted.
Remove the control board cover and check if the F2 fuse appears to
have blown. Replace it with a 3 Amp 250V fuse. Plug the stove
back and try to run the unit.
2.
The auger fuse has blown.
Start by emptying the hopper. Then, remove the auger motor by
removing the screws holding the motor to the auger shaft Once the
motor is out, remove the four screws on the steel plate holding the
auger shaft to the auger housing. Then, rotate the bottom end of the
auger shaft down towards you until you can pull the shaft down out
of the stove. After you have removed the shaft, inspect it for bent
flights, burrs, or broken welds. Remove any foreign material that
might have caused the jam. Also, check the auger housing for signs
of damage such as burrs, rough spots, or grooves cut into the metal
that could have caused a jam. Clean the auger housing thoroughly
to remove all pellet dust. Repeat the process whit the burn pot auger
motor.
STOVE STOPS FEEDING PELLETS AND
APPEARS ON THE CONTROL BOARD
Possible Cause:
Possible Remedy:
1.
The L-250 automatic high temperature switch is located on the top of
the auger housing. It sends a signal to the control board if the auger
housing overheats. Wait until the stove cools down AND THEN
INSPECT YOUR UNIT. Improper installation, poor maintenance, or a
defective or missing component may be causing the stove to
overheat. Reset the stove and restart it. Call a technician if you get
this code again.
An overheat zone was detected on the auger housing
*** After 3 attempts, reset is no longer possible, call SBI technical support.
STOVE STOPS FEEDING PELLETS AND
APPEARS ON THE CONTROL BOARD
Possible Cause:
1.
The hopper lid has stayed open for more than 3 minutes
Possible Remedy:
As a security measure, the auger stops turning and feeding pellets
as soon as the hopper lid opens. It will resume normal operation as
soon as the hopper lid is closed. If the hopper lid stays open for
more than 3 minutes, the unit will stop and a code “d” will appear on
the control board. Close the hopper lid. Reset the unit and start it
again.
If the lid is properly close the hopper lid switch is defective or
misconnected
SMOKE SMELL COMING BACK INTO THE HOME
Possible Causes:
1.
There is a leak in the vent pipe system.
2. A gasket on the exhaust blower housing or on the cleanout trap
is in bad condition.
Possible Remedies:
Inspect all vent pipe connections. This is a pressurized exhaust
system. All vent connector joints must be sealed and fastened in
accordance with the pellet pipe manufacturer's instructions to ensure
consistent performance and avoid smoke and ash spillage.
Inspect the gasket on the exhaust blower housing to make sure it is
in good condition. Make sure that all cleanout trap gaskets are in
good condition and all bolts are tight.
AUGER MOTOR STOP FEEDING PELLETS AND COMES BACK ON
Possible Cause:
Possible Remedy:
1.
Start by emptying the hopper. Then, remove the auger motor by
removing the screws holding the motor to the auger shaft Once the
motor is out, remove the four screws on the steel plate holding the
auger shaft to the auger housing. Then, rotate the bottom end of the
auger shaft down towards you until you can pull the shaft down out
of the stove. After you have removed the shaft, inspect it for bent
flights, burrs, or broken welds. Remove any foreign material that
might have caused the jam. Also, check the auger housing for signs
of damage such as burrs, rough spots, or grooves cut into the metal
that could have caused a jam. Clean the auger housing thoroughly
to remove all pellet dust. Repeat the process whit the burn pot auger
motor.
The auger motor is overheating and tripping the internal
temperature shutoff (thermal protector).
x GLASS “SOOTS” UP AT A VERY FAST RATE
x FLAME IS LAZY, DARK, AND HAS BLACK TIPS
x AFTER STOVE HAS BEEN ON FOR A WHILE, THE BURNPOT OVERFILLS
Possible Causes:
Possible Remedies:
1.
Stove or vent pipe is dirty, which restricts airflow through the
burn pot.
Follow all cleaning procedure in the maintenance section of the
owner’s manual.
2.
Vent pipe installed improperly.
Check to make sure the vent pipe has been installed according to
the criteria in the owner’s manual.
3.
Burn pot holes are blocked.
Remove the burn pot and clean it thoroughly.
4.
Blockage in air intake pipe.
Visually inspect the air intake pipe that leads into the burn pot for
foreign material.
5.
Combustion blower is not working properly.
Check if the blower is still working (separately – bypassing the
control board). Make sure that there is not any obstruction in the
fresh air kit and into the air intake tube.
6.
Bad pellets
(Applies to “GLASS SOOTS UP AT A VERY FAST RATE” Only)
The brand of pellets or the batch of pellets that are being used may
be of poor quality. If possible, try a different brand of pellets. You
might also want to try a brand that is made from a different type of
wood (softwood vs. hardwood). Different woods have different
characteristics when being burned. Your pellets may also be too
humid. Make sure you store your fuel properly, in a dry ventilated
area.
x The control board does not display any information.
Possible Cause:
Possible Remedy :
1. A fuse on the control board has blown.
Remove the control board. Check if the F7 fuse on the back of it
appears to be bad. Replace it with a 7.5 Amp 250 Volt fuse. Plug
the stove back in and try to run the unit.
THE STOVE IS RUNNING BUT DISPLAYS WARNING CODE
Possibles Cause:
Possible Remedy :
Warning generated by a power failure while the stove was
running.
The stove will restart on the initial setting once it cools off.
Note: For a short power failure (less than 5 seconds), the stove will continue
to function at the selected speed.
44
ALARM CODES CHART
MESSAGE
CORRESPONDING WARNING
Pressure switch warning.
Warning caused by the automatic L-250 sensors: it is located over the pellet housing.
Hopper is empty
Lighting warning.
Hopper lid stayed open more than 3 minutes.
Inverted polarity in power outlet.
Power outage
Igniter fuse is blown
Auger fuse has blown
SMOKE SMELL OR SOOT BUILD-UP
Because it is a wood-burning device, your Drolet ECO-65 may emit a faint wood-burning odor. If this increases
beyond normal, or if you notice an unusual soot build-up on walls or furniture, check your exhaust system
carefully for leaks. All joints should be properly sealed. Also clean your stove, following instructions in
“MAINTENANCE”. If problem persists, contact your dealer.
45
5.
ELECTRICAL DIAGRAM
FIGURE 26
46
FIGURE 27
5.1.
FIGURE 28
FUSE ACCESS
All fuses are located inside the pc board box, you must remove the pc board cover to access the fuse. To do so,
simply remove the 5 screws securing it in place. Make sure you put the pc board box back in place before you
restart the unit.
FIGURE 29
47
6.
REPLACEMENT PARTS
Contact an Authorized DROLET Dealer to obtain any of these parts. Never use substitute materials. Use of nonapproved parts can result in poor performance and safety hazards.
#
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
ITEM
1/2 " CHROME PLATED COIL HANDLE
CAST IRON DOOR WITH GASKET, HANDLE AND LATCH
BLACK 1/2'' ROUND X 9' GASKET KIT WITH ADHESIVE
HANDLE AND LATCH KIT
DOOR LATCH KIT
SPRING TENSION PIN 5/32" DIA X 1 1/2" LONG
SELF-ADHESIVE 1/8" X 3/8" GASKET HB26
ARCHED REPLACEMENT GLASS
BOTTOM GLASS RETAINER
TOP GLASS RETAINER
SCREW #8 - 32 X 5/16'' TRUSS QUADREX ZINC
BAFFLE
COMBUSTION POT ASSEMBLY
BURN POT SUPPORT ASSEMBLY
ROUND GASKET AND SILICONE KIT 5/16" X 6.6'
FIRE POT LATCH
ZINC WASHER ID 13/32" X OD 13/16"
WING NUT 3/8"-16
ASH DRAWER ACCESS DOOR
PIN 5/16" x 1 1/2"
ASH DRAWER
HING PIN 5/16" x 2"
500W - 120V IGNITER
SPRING CLIP
LEVELING BOLT 3/8-16 X 1 1/2"
FRESH AIR INTAKE TUBE GASKET
THERMODISC 36T11 L250-25 AUTOMATIC
2 FOLD ALUMINUM LINER 3" X 14'' COMPRESSED TO 7"
3" TO 4" STAINLESS STEEL COLLAR
THERMODISC 36T12 F160
JUNCTION WIRE MAIN CONTROL BOARD TO LCD
DECORATIVE RIGHT SIDE ASSEMBLY
HOUSING FOR ELECTRONIC CONTROL BOARD MEMBRANE
CONTROL BOARD MEMBRANE SWITCH
BLOWER WITH CAPACITOR (500 PCM, 115v, 60Hz, 1100 TPM)
BLOWER ANTI-VIBRATION CUSHION
RIGHT BLOWER MOUNT
BLOWER (500 CFM, 115v, 60Hz, 1100 RPM)
CAPACITOR 10MF
CAPACITOR HOUSING
BUILT TO ORDER
WOOL SEAL FOR BLOWER
PRESSURE SWITCH
3/8'' X 42" SILICONE HOSE
AIR PUMP 120VAC/60Hz 0.15A
AIR INTAKE BOX ASSEMBLY
COMBUSTION BLOWER 120V-60Hz
# PIÈCES
AC07867
SE24219
AC06900
AC09155
AC09185
30101
40018
PL62417
PL62415
PL62416
30124
PL62412
SE62254
SE62302
AC06300
30686
30205
30416
SE62325
30341
SE62290
30363
44133
30710
30050
21345
44059
21077
49400
44058
60327
SE62340
SE62330
44139
SE44108
30335
PL62359
44108
60323
PL62420
99999
21350
44029
49606
60047
SE62306
44104
Qty
1
1
2
1
1
1
5.1333
1
1
1
12
1
1
1
1
1
1
1
1
2
1
2
1
24
4
1
1
1
2
1
1
1
1
1
1
4
2
1
1
1
1
1
1
2
1
1
1
48
#
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
ITEM
THERMOSTAT TERMINAL
6 OUPUT MOTHER BOARD
REAR VENTILATION LOUVER
UPPER REAR PANEL
POWER CORD 96" X 18-3
AUGER
GEAR MOTOR BRACKET
AUGER SUPPORT INSULATION
GEAR MOTOR FOR PELLET STOVE 3.5 RPM
GEAR MOTOR FOR PELLET STOVE 1.7 RPM
AUGER BUSHING PLATE
PRIMARY CHUTE GASKET
HOPPER LID SAFETY SWITCH
THERMISTOR
EXHAUST FAN ASSEMBLY
EXHAUST BLOWER GASKET
HOPPER LID ASSEMBLY
HINGE 2'' X 1-1/2''
HOPPER LID PLASTIC HANDLE
FRONT TOP ASSEMBLY
TOP DECORATIVE GRILL
FRONT LOUVER
MAINTENANCE GASKET KIT– PELLET HEATER
DECORATIVE LEFT SIDE ASSEMBLY
ECO 65 INSTRUCTION MANUAL KIT
HOT AIR PLENUM KIT – 4" x 10"
# PIÈCES
60036
44138
PL62350
PL62349
60013
24030
24233
21193
44109
44106
PL62281
21195
44098
44095
SE62293
21194
SE62344
30013
30527
SE62345
SE62389
PL62339
AC09190
SE62341
SE45433
AC01330
1
1
1
1
1
1
1
2
1
1
1
1
1
1
1
1
1
2
1
1
1
1
1
1
1
1
49
50
APPENDIX A
PossibleVerticalvent
length(feet)
HORIZONTAL AND VERTICAL VENT CHART
PossibleHorizontal
ventlength(feet)
For example, let’s imagine an installation consisting of a horizontal vent coming out at the back of the stove
on a total distance of 8 feet. This horizontal run is followed by a Tee and a 6-foot vertical rise. This type of
installation is not acceptable. As you can see, the vent termination is clearly outside the allowed configuration
zone on the chart because the venting system proposed does not have at least one foot of vertical rise for
each foot of horizontal run.
Instead, if the installation consisted of a horizontal vent coming out at the back of the stove on a total distance of
4 feet, followed by a Tee and a 6-foot vertical rise, it would be acceptable. The installation end should be within
the allowable configuration zone on the chart since it would have at least one foot of vertical rise for each foot of
horizontal run. Furthermore, the total vertical rise would be at least 3-foot high.
WARNING: TO REDUCE THE RISK OF SMOKE SPILLAGE, NEVER TERMINATE WITH A HORIZONTAL
RUN. IF YOUR SYSTEM TERMINATES WITH A HORIZONTAL RUN, ADD AT LEAST 3 FEET
OF VERTICAL RISE.
51
APPENDIX B
INSPECTION FORM
52
DROLET LIMITED LIFETIME WARRANTY
The warranty of the manufacturer extends only to the original consumer purchaser and is not transferable. This
warranty covers brand new products only, which have not been altered, modified nor repaired since shipment from
factory. Proof of purchase (dated bill of sale), model name and serial number must be supplied when making any
warranty claim to your DROLET dealer.
This warranty applies to normal residential use only. Damages caused by misuse, abuse, improper
installation, lack of maintenance, over firing, negligence or accident during transportation, power failures,
downdrafts, or venting problems are not covered by this warranty.
This warranty does not cover any scratch, corrosion, distortion, or discoloration. Any defect or damage caused by
the use of unauthorized parts or others than original parts void this warranty. An authorized qualified technician
must perform the installation in accordance with the instructions supplied with this product and all local and
national building codes. Any service call related to an improper installation is not covered by this warranty.
The manufacturer may require that defective products be returned or that digital pictures be provided to support
the claim. Returned products are to be shipped prepaid to the manufacturer for investigation. If a product is found
to be defective, the manufacturer will repair or replace such defect. Transportation fees to ship the product back to
the purchaser will be paid by the manufacturer. Repair work covered by the warranty, executed at the purchaser’s
domicile by an authorized qualified technician requires the prior approval of the manufacturer. Labour cost and
repair work to the account of the manufacturer are based on predetermined rate schedule and must not exceed
the wholesale price of the replacement part. All parts and labour costs covered by this warranty are limited
according to the table below.
The manufacturer at its discretion may decide to repair or replace any part or unit after inspection and
investigation of the defect. The manufacturer may, at its discretion, fully discharge all obligations with respect to
this warranty by refunding the wholesale price of any warranted but defective parts. The manufacturer shall in no
event be responsible for any special, indirect, consequential damages of any nature, which are in excess of the
original purchase price of the product. A one-time replacement limit applies to all parts benefiting from a lifetime
coverage. This warranty applies to products purchased after October 1st, 2011.
WARRANTY APPLICATION
PARTS
LABOUR
DESCRIPTION
Combustion chamber (welds only), heat exchanger (welds only),
auger, and castings.
Stainless steel firebox components, surrounds and heat shields, ash
drawer, pedestal, trims (aluminum extrusions), and plating* (defective
manufacture).
Carbon steel firebox components, burn pot, glass retainers, and
handle assembly.
Blowers, auger motor, PC board, igniter, heat sensors, switches,
wiring, rheostat, and other controls.
Ceramic glass (thermal breakage only*), paint (peeling), gaskets,
insulation, ceramic logs, masonry-like panels, and ceramic fibre
blankets.
*Pictures required
Lifetime
3 years
5 years
3 years
3 years
1 year
2 years
1 year
1 year
n/a
Shall your unit or a components be defective, contact immediately your DROLET dealer. Prior to your call make
sure you have the following information necessary to your warranty claim treatment:
x
x
Your name, address and telephone
number;
Bill of sale and dealer’s name;
x
x
Serial number and model name as indicated on
the nameplate fixed to the back of your unit;
Nature of the defect and any relevant information.
Before shipping your unit or defective component to our plant, you must obtain from your DROLET
dealer an Authorization Number. Any merchandise shipped to our plant without authorization will be
refused automatically and returned to sender.