Download Whynter T-2M/A Instruction manual

Transcript
WHYNTER ENERGY STAR 50 PINT PORTABLE
DEHUMIDIFIER WITH PUMP
Model # : RPD-501WP
INSTRUCTION MANUAL
Congratulations on your new Whynter product. To ensure proper operation, please read this Instruction Manual carefully before
using this product. Keep this manual in a safe place for future reference.
DISPOSAL INFORMATION
Thank you for choosing the Whynter Portable Dehumidifier. Please follow the
instructions provided in this user guide to obtain the very best performance
from your dehumidifier. We trust that your Whynter dehumidifier will provide
the performance and reliability that we stand for.
Your Whynter dehumidifier is designed to remove moisture in the air by condensation removal and collecting the condensation water in the drain bucket
or draining through a drain hose.
Please keep this user manual in a safe place for future reference.
This symbol on the product or its packaging indicates that the appliance cannot be treated as normal domestic trash, but must be handed in at a collection
point for recycling electric and electronic appliances. Your contribution to the
correct disposal of this product protects the environment.
Further information about the recycling of this product can be obtained from
your local municipal authority.
2
TABLE OF CONTENTS
PAGE
DISPOSAL INFORMATION
2
SAFETY PRECAUTIONS
4
INTRODUCTION / TECHNICAL DATA
5
PARTS AND CONTROLS
6-9
OPERATION INSTRUCTIONS
10 - 11
WATER DRAINAGE INSTRUCTIONS
12 - 14
MAINTENANCE
15
TIPS ON WHEN TO USE YOUR PORTABLE DEHUMIDIFIER
16
TROUBLESHOOTING
17 - 18
WARRANTY INFORMATION
19
3
SAFETY PRECAUTIONS
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR INJURY
WHEN USING YOUR PORTABLE DEHUMIDIFIER, FOLLOW THESE
BASIC PRECAUTIONS:
 Read all instructions before using the appliance.
 Never clean appliance parts with flammable fluids. The fumes can create a fire hazard. Do not use an excessively wet cloth, industrial solvents, and oil-based products to clean this appliance.
 Do not store or use gasoline or any other flammable vapors and liquids in the vicinity of this or any other appliance. The fumes can create a fire hazard.
 Do not abuse, sit on, or stand on the appliance.
 This appliance is not intended for use by persons (including children with reduced physical, sensory or mental
capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
 Children should be supervised to ensure that they do not play with the appliance.
 If the power cord is damaged, it must be replaced by the manufacturer or its service agent or a similarly qualified person in order to avoid a hazard.
 Please dispose of packing materials properly.
 Use the portable dehumidifier only for its intended function. This appliance is designed for household, noncommercial use only. Any other use will void the warranty.
 To avoid the risk of shock, the product should never be used in bathrooms, shower rooms, or in any other
steamy or wet areas.
 During installation, the power supply must not be excessively or dangerously bent or flattened.
 Do not tamper with controls.
 Make sure the power plug is placed fully and firm into the wall socket. If the wall receptacle you intend to use is
not adequately grounded or protected by a time delay fuse or circuit breaker, have a qualified electrician install
an outlet that is appropriate to local electrical codes and requirements.
 Do not use multiple socket or of an extension cord as it may overheat and become a risk of fire.
 Make sure the power plug is clean before usage.
 Do not turn this appliance on and off by plugging and unplugging. Always use the ON/OFF switch.
 After turning the appliance off, please take the power plug out of the socket.
 Make sure hands are dry when connecting the power plug. The appliance is equipped with a three-prong
grounded plug on the power cord for your protection. Never modify, remove or attempt to repair the power plug
yourself.
 Do not repair, disassemble and/or modify the appliance by yourself.
 Always turn off the appliance when cleaning the air filter, and transporting.
 At the end of each season, all water must be drained from the appliance and air filter must be cleaned before
storage.
 Do not drink or use the water collected or drained from the appliance.
 Do not remove the drain bucket during operation.
 Transport the appliance in an upright position only, or leave it in an upright position for at least 2 hours before
first use.
 When positioning or moving the appliance, ensure that it is not turned upside down or greater than 45° or more
off level.
 This appliance must be installed in an area protected from the element, such as wind, rain, water spray or drips.
 Always place the appliance on even and hard and level surface that can support the unit when it is full of wa-
ter.
 Ensure objects are not obstructing the exhaust and air intake.
 Never insert your fingers or other objects into the air intakes and air outlets.
 Do not operate the appliance without the air filter.
THE MANUFACTURER DISCLAIMS ANY RESPONSIBILITY IF THE ABOVE INSTRUCTIONS ARE NOT
FOLLOWED
4
INTRODUCTION
How it Works
When the dehumidifier is started, the fan begins to pull moisture-laden air across the dehumidifying coils.
The coils condense or draw moisture from the air, and air flows through the top louver into the room as dry,
warm air. Moisture removed from air is collected in a drain bucket on the front of the dehumidifier.
The appliance is designed to operate between 41°F (5°C), and 96°F (35°C). The "Compressor" circuit has
an automatic 3 minute time delayed start if the appliance is turned off and on quickly. This prevents over-
heating of the compressor and possible circuit breaker tripping. Make sure the drain bucket is fitted correctly
otherwise appliance will not turn on.
Energy Saving Guide
This Whynter dehumidifier is an Energy Star rated appliance. Follow the guide below can help to get the
best performance and efficiency from your dehumidifier.





Do not cover the air intake and outlet.
Do not place the appliance in front of curtains or drapes- to ensure they do not obstruct the air intake.
Keep curtains, blinds or drapes closed during the sunniest part of the day.
Close all windows and doors.
Indoor relative humidity should ideally be kept between 35%RH and 60%RH depending on the ambient
temperature.
 Make sure the appliance is on a hard and level surface.
 To prolong the compressor's life, please wait at least 3 minutes before turning the appliance back on
after shutting it off.


Inspect and keep the air filter clean by cleaning regularly.
Perform routine maintenance.
TECHNICAL DATA
MODEL :
RPD-501WP
Dehumidifying capacity
50 pint
EEV (Liters per kW-Hour)
1.85 L/kWh
Power supply
115 V /60 Hz
Maximum power input
520 Watts
Current Consumption
4.7 Amps
Refrigerant
R410A/7.76oz
Air flow M3/H / CFM
320 m3/h / 188 CFM
Fan speeds
2
Unit Dimensions
15.8” W x 11.3” D x 23.6” H
Unit Net Weight
38 lbs
Unit Gross Weight
42 lbs
Noise Level (dBA)
< 58.5 dBA
5
PARTS AND CONTROLS
OTHER ACCESSORIES:
1. 20“ Continuous/ Gravity Drain
hose
2. Continuous/ 6.75” Gravity
Drain short hose and adapter
3. 16.5 ft. pump drain hose
4. Screws (2 pieces)
6
PARTS AND CONTROLS
1. Pump Button
Press to activate the pump operation. The Pump indicator light will illuminate when water pump is in operation.
Note: Make sure the pump drain hose is installed into the unit and the continuous/gravity drain assembly is removed from the unit before the pump operation is activated. The water pump function will start when the drain
bucket is full.
2. Filter Button
The check filter indicator is a reminder to clean the air filter for more efficient operation. The filter light will illuminate
after approximately 250 hours of operation. To reset after cleaning the filter, press the Filter button and the light will
turn off.
3. Fan Button
Press to select either Turbo or Normal fan speed. Press the Fan button to engage Turbo Fan mode. The Turbo
light will illuminate. Press the Fan button again to set the unit to Normal Fan mode. The Turbo light will turn off
when Normal Fan mode is activated.
4. Power Button
Press to turn the dehumidifier on and off
5 - 6. Down/Up Buttons
 Humidity Set Control Buttons
The humidity level can be set within a range of 35%RH(Relative Humidity) to 85%RH in 5% increments. For
lower humidity level, press the Down button and set to a lower RH percentage value. For higher humidity
level, press the Up button and set to a higher RH percentage value.
 Timer Set Control Buttons
If Timer Button is pressed, use the Up and Down buttons to set the Auto Start and Auto Stop time from 0.0
hour to 24 hours.
7
PARTS AND CONTROLS
Energy Saver
When the unit is running on normal operation, once the RH% is reached, the fan will still run continuously to avoid
high start-up amperage which makes the unit energy-efficient . Please note that the fan may run continuously or
shut off intermittently depending on the RH% and set humidity.
7. Timer Button
Press to activate the Timer delay feature, in conjunction with the Down and Up Buttons.
 Timer Delay Switch Off
When the appliance is ON, press the Timer button to activate Auto-stop function and the Timer OFF
light will come on. Set the desired time delay OFF hours by pressing the UP and DOWN buttons. The
time increments are 1 hour up to 24 hours. When the delay time set has elapsed, the appliance switches off. To cancel the delayed switch off function, set the time to “00” or turn off the appliance.
 Timer Delay Switch On
When the appliance is OFF, press the Timer button to activate Auto-start function and Timer ON light
will come on. Set the desired time delay ON hours by pressing the UP and DOWN buttons. The time
increments are 1 hour up to 24 hours. When the delay time set has elapsed, the appliance turns on. To
cancel the delayed switch on function, set the time to “00” or turn off the appliance.
 Timer Delay Switch On and Off Sequence
When the appliance is OFF, press the Timer button to activate Auto-start function and Timer light ON
will come on. Set the desired time delay ON hours by pressing the UP and DOWN buttons. Once Timer
Delay Switch On is placed, press the Timer button again to activate Auto-stop function and the Timer
OFF light will come on. Set the desired time delay OFF hours by pressing the UP and DOWN buttons.
When the delay time set has elapsed, the appliance switches off. To cancel the delayed switch off func-
tion, set the time to “00” or turn off the appliance.
Bucket Full Indicator
The appliance will run continuously until the set RH% is reached or when the drain bucket is full. When the drain
bucket is full, the Full indicator light will illuminate and the dehumidifier will stop operating. Remove the water in the
bucket with two hands, then place the drain bucket back to it's proper position and the machine will start operating
again.
NOTE: The Full Indicator light will be off even if the water is full in Water Pump Drain Method. See page 13.
Auto Defrost Indicator
In the event frost builds up on the evaporator coils, the compressor will cycle off and the fan will continue to run
until the frost is evaporated. This happens when the appliance is operating in low temperatures (less than 53°F or
12°C), which affects the efficiency of the dehumidifier. When this happens, the Auto Defrost light will turn on and
the machine will go into periodic defrost mode automatically. Defrost time may vary. If the dehumidifier freezes up,
turn the appliance off for few hours and then restart. The appliance will not operate satisfactorily if the room temperature is below 41°F
8
PARTS AND CONTROLS
Continuous Indicator Light
To run the unit in continuous mode, press the Down button until the display reads 35%RH. Then press the Down
button again until the display reads “CO” to initiate continuous operation and the Continuous indicator light will illuminate. To stop continuous operation, press the Up button and set the desired RH percentage value to resume normal
operation.
Display
The display screen shows a number of different indications depending on the selection function.

Shows the set % relative humidity level from 35%RH to 85%RH.

Shows Auto Start and Auto Stop time from 0.0 hour to 24 hours.

After the option settings are completed, the display shows the approximate room humidity level in a range of
30%RH (Relative Humidity) to 90%RH .
Error Codes and Protection Code
AS - Humidity Sensor Error
Unplug the unit and plug it back in.
ES - Temperature Sensor
Error
Unplug the unit and plug it back in.
P2 - Drain Bucket Full
Empty the drain bucket.
Please make sure float moves freely and is not stuck .
EC - Unit Malfunction
Please make sure whether the environment temperature is
between 41°F (5°C), and 96°F (35°C).
E3 - Unit Malfunction
Unplug the unit and plug it back in.
Eb - Drain Bucket Error
Drain bucket is removed or not positioned correctly. Make
sure that the drain bucket is properly installed and the in
right position.
Auto Restart
In the event of a power outage, appliance restarts at the previously set function mode and settings when power is
restored (not applicable to Timer Function).
9
OPERATION INSTRUCTIONS
AIR FILTERS INSTALLATION
Your Whynter portable dehumidifier is equipped with a 2 in 1 silver-coated washable pre-filter combo. This washable
pre-filter removes large particles such as dust, pet hair and dander. The silver coating is designed to kill bacteria in
the air and control the growth of microbes, such as viruses, fungi and spores.
WARNING: NEVER OPERATE THE DEHUMIDIFIER WITHOUT THE FILTER
START OPERATION
1. Ensure that the appliance is connected to the power socket.
2. Make sure the drain bucket is placed in proper position.
3. Make sure filter is installed.
4. When the unit is turned on for the first time, if the bucket full lamp lights up, just pull out the drain bucket then
push it back to the proper position.
5. Set the relative humidity level RH% by pressing the up and down buttons. We recommend setting the RH% to at
least 10% lower than the current RH%.
10
OPERATION INSTRUCTIONS
POSITIONING THE UNIT

This dehumidifier is intended for indoor residential applications only and should not be used for commercial or
industrial applications.

Place the dehumidifier on a smooth, hard and level floor strong enough to support the appliance with a full
bucket of water.

Do not attempt to roll the appliance over objects.

Avoid placing the appliance in an area where the temperature will fall below 53°F. The coils may become covered with frost and may reduce performance.

Do not place the appliance near clothes dryer, heater or radiator.

Shut all doors, windows and openings to your target dehumidifying space for maximum performance.

Allow at least 10” of air space on all sides of the appliance for good air circulation and 20” or more above the
appliance.
NOTE:

Dehumidifiers working in a basement will have little or no effect on adjacent enclosed rooms such as closets,
unless there is enough circulation of air in and out of the enclosed area.

If the appliance has been switched off and needs to be switched on again, allow approximately three minutes
for the correct operation to resume.

Select a suitable location and make sure you have easy access to the electrical outlet.

Ensure the air filter and drain bucket are correctly installed before switching the appliance on.

Always be careful when moving the appliance with a full drain bucket.

Ensure that the safety requirements and warnings detailed in this user manual are followed when operating this
appliance.
11
WATER DRAINAGE INSTRUCTIONS
Using a portable dehumidifier requires that collected water be emptied frequently. Draining water from this unit
can be done in 3 different methods:
1. DRAIN BUCKET METHOD
1. The drain bucket can hold up to 14 pints of water. When the bucket is full, the Full indicator light will light. The compressor and fan will
turn off, the Full indicator will light, and a P2 code will be displayed.
2. It is recommended to turn the unit off before removing the drain
bucket.
3. Grip the left and right handles of the drain bucket securely and
carefully pull out the drain bucket. Do not put the drain bucket on the
floor because the bottom of the bucket is not even which may cause
the water to spill. See Fig.5 and Fig.6.
4. Remove the water from the drain bucket and replace it back to the
dehumidifier. The drain bucket must be installed properly and securely seated for the dehumidifier to operate.
5. The machine will restart when the drain bucket is restored in its
correct position. If the unit was turned off prior to the removal of the
drain bucket, press the Power button to restore operation.
NOTES:
 When you remove the drain bucket, do not touch any inside parts of
the unit. Doing so may damage the product and result to injury.
 Be sure to push the drain bucket gently all the way into the unit.
Banging the bucket against anything or failing to push it in securely
may cause the unit not to operate.
 If the pump filter drops when you remove the bucket (see Fig.7), you
must reinstall the pump filter properly to the unit before replacing the
drain bucket into the unit (see Fig.8).
 Upon replacing the bucket, firmly push the bucket in place until it
locks. There should be no gaps between the bucket and the dehumidifier.
 When the drain bucket is removed, the unit will beep 8 times and the
digital display shows Eb. Eb is an error code that indicates that
the drain bucket is removed or not positioned correctly. Make sure
that the drain bucket is properly installed and the in right position.
12
WATER DRAINAGE INSTRUCTIONS
2. CONTINUOUS / GRAVITY DRAIN METHOD
Water can be automatically emptied into a floor drain by attaching the 20” continuous/gravity drain hose to the continuous/gravity drain outlet. To use gravity to drain your portable dehumidifier, it must be installed on a level surface
or at least 12 inches above the ground, on a sturdy table or shelf unit. When using the function of continuous/
gravity drainage, your drain hose must be placed horizontally below the drainage hole. Avoid uneven ground and
folding the hose.
1. Install the continuous/gravity drain hose
(short hose) onto the continuous hose
adapter (See Fig.9) .
2. Remove the rubber drain cover from the
continuous/gravity drain outlet at the back of
the unit.
3. Remove the drain bucket.
4. Insert the continuous/gravity drain hose
assembly through the continuous/gravity
drain outlet (See Fig.10).
5. From the front of the unit and with the
drain bucket removed, make sure the continuous/gravity drain hose is securely inserted
to the internal connector (See Fig.11).
6. Install the two screws provided to the continuous/gravity drain hose adapter from the
back of the unit.
7. Attach the 20” continuous/gravity drain
hose. Make sure the hose is securely fastened to prevent leakage (See Fig.12).
8. Direct the drain hose toward a drain or other suitable drainage outlet. Make sure that there
are no distortions with the hose that may stop the water flow.
9. Place the drain bucket back into the unit and make sure that it is installed correctly.
10. Select the desired humidity setting and fan speed on the unit for continuous draining to
start.
13
WATER DRAINAGE INSTRUCTIONS
3. WATER PUMP METHOD
One of the key features of this dehumidifier is that it has a water pump that pushes water up or over a longer distance. Using this feature will enable your unit to run maintenance free.
NOTE: The water pump will ONLY engage when the drain bucket is full.
1. Make sure the continuous/gravity drain assembly is removed from the continuous/gravity drain
outlet and the plastic cover is installed.
2. Insert the 16 ft. pump drain hose (included)
into the bottom pump drain outlet (See Fig.14),
then lead the drain hose to a suitable drainage
facility. Make sure that the hose is fully inserted
to avoid water leakage and no kinks which will
cause the water to stop flowing.
3. Press the Pump button to activate the pump operation.
NOTE: The water pump will ONLY engage when the drain bucket is full.
4. The water pump may make some noise when it starts to work within the first 3 - 5 minutes. This is
a part of the unit’s normal operation.
5. Select the desired humidity setting and fan speed on the unit.
NOTE: The Pump Indicator Light will flash when there is a failure in the pump operation. Please turn off the unit and
unplug the power cord and check the following points:
Clean the pump filter - remove the drain bucket from the
unit, pull down the pump filter, and clean (See Fig.15).
Check the pump drain hose for kinks or obstructions
Reinstall the pump filter and drain bucket properly. Turn on
the unit. If the error repeats, call for service.
NOTE: Do not use this operation when the outdoor temperature is equal to or less than 32°F. Otherwise, water hose
may be blocked as the water will turn to ice and cause the
unit to fail. When the pump drain feature is not being used,
remove the pump drain hose from the outlet.
14
MAINTENANCE
Always turn off and unplug the dehumidifier before cleaning.
1. Cleaning the air grille and main unit
 Use a damp cloth to wrap the main unit or use water and a mild detergent. Do not use bleach, chemicals or
abrasives.
 Do not splash water directly onto the unit. Doing so may cause an electrical shock, cause the insulation to deteriorate, or cause the unit to rust.
 Use a vacuum attachment or brush to clean the air intake and outlet grilles.
2. Cleaning the bucket
 Clean the bucket to prevent growth of mold, mildew and bacteria every two weeks.
 Fill the bucket with clean warm water and add mild detergent to the water.
 Dry thoroughly before reinserting the bucket to the main unit.
NOTE: Do not clean the bucket in a dishwasher.
3. Cleaning the air filter
To ensure the air intake is filtered properly and to assure that your dehumidifier runs efficiently, it is recommended to clean the air filter at least once every two
weeks.
 Use a vacuum cleaner or tap the filter lightly to remove loose dust and dirt.
 Rinse the air filter under warm or cold running water (no hotter than 100F.)
 Dry thoroughly before reinserting the air filter.
 Reinstall the air filter and replace bucket securely.
4. End of Season Storage
 After turning off the unit, wait 24 hours before emptying the bucket to allow
excess moisture to drain into the bucket.
 Clean the main unit, drain bucket and air filter as detailed above.
 Cover the unit with the original plastic bag that came with the unit or any appropriate dust cover.
 Store the unit upright in a dry, well-ventilated place.
15
TIPS ON WHEN TO USE YOUR PORTABLE DEHUMIDIFIER
If you have respiratory problems, asthma and allergies, your Whynter RPD-501WP portable dehumidifier is a great
option for controlling moist environments. Creating dry air can keep indoor air pollutants at a more manageable level, especially when used in conjunction with an air purifier. Using your portable dehumidifier can help you save money in the long run because it uses relatively little power and can help furnaces and air conditioners operate more
efficiently.
1. Excess moisture
Indoor environments with excessive moisture can cause mold and fungus to thrive inside the walls and beneath the carpet. Many types of mold are potentially dangerous and can lead to health problems. The Whynter RPD
-501WP portable dehumidifier reduces the amount of moisture in the air inside a home, which makes it far more
difficult for harmful mold to grow. This portable dehumidifier is also effective for a small area, such as a hallway or
bedroom.
2. Respiratory problems or allergies
The Whynter RPD-501WP is a 50-pint portable dehumidifier which is perfect for larger rooms or areas in
your home, including a living room or family room. If your home is musty, you will want to use your portable dehumidifier, especially if you have respiratory trouble or allergies. This unit can also help relieve symptoms by controlling the relative humidity inside your home and a good idea in general if your home has such underlying problems
as a leaky foundation walls or inadequate ventilation or if you live in a humid area. By keeping the relative humidity
indoors below 50 percent, you can keep allergy-inducing dust mites and mold from thriving.
3. Basements
If you have a basement that is below-grade, you should use your Whynter RPD-501WP portable dehumidifier. This dehumidifier will help you keep the moisture levels in your basement down to manageable levels. By doing
this, you can help keep your indoor furnace operating efficiently and even help eliminate minor standing-water problems. Your portable dehumidifier also can help keep furniture and valuables dry, and it will help keep electronics in
proper working order.
4. Humid climates
In humid climates, such as areas near a beach or large body of water, your Whynter RPD-501WP portable
dehumidifier can help keep the environment in your home at a more comfortable level. While the actual temperature
won't be affected, you'll sleep more comfortably and may actually save money, since your unit can keep the indoor
humidity and, thus, your thermostat under control.
16
TROUBLESHOOTING
Many common portable dehumidifiers problems are easily resolved. Try the troubleshooting suggestions
below to see if the problems can be resolved before having to contact the service department.
Problem
The dehumidifier does not
operate.
Possible Causes
 Power failure / outage.
 The automatic switch, line fuse,
or breaker has been tripped.
 The power supply voltage is
too low.
 The power cord is damaged.
 The dryness level you selected
has been reached.
 Drain bucket is full or not
positioned properly.
The dehumidifier runs too
much.
 Windows or doors near dehumidifier are open.
 Area to be dehumidified is too
large.
 Air movement through dehumidifier is blocked. Air grille
may be dirty.
 Continuous mode is on.
The dehumidifier runs but the  Humidity setting (RH%) is too
room is not dry enough.
high.
 The dehumidifier does not have
sufficient clearance to operate.
 Room temperature is too low.
 Windows or doors are opened .
Frost appears on the coils
above the bucket.
 The dehumidifier has been
turned on recently.
 Room temperature is too low.
The dehumidifier makes loud
noise.
 Appliance is not leveled.
17
Solutions
 Restore the power supply.
 Flip the switch / change the fuse / turn the
breaker back on. Also note that you may
have too many appliances drawing power
on one circuit, you may need to move the
other appliances to another circuit.
 Move the appliance onto another circuit
with the correct voltage.
 Call for service. Only authorized personnel should replace damaged power cord
or power plug.
 If you want to remove more moisture, set
the unit on Continuous operation.
 Empty drain bucket and insert the bucket
to the appliance properly.
 Close all windows or doors.
 You may need an additional dehumidifier
for area.
 Clean the air filter.
 The appliance must be placed in a space
that does not restrict air flowing into the
rear coil or out of the front grille.
 Set the RH% level and the appliance will
stop when the set RH% is reached.
 Set the humidity level to a lower RH%.
We recommend setting the RH% to at
least 10% lower than the current RH%.
 Ensure there is at least 10” of clearance
for proper ventilation.
 The appliance will not operate satisfactorily if the room temperature is below 41°F
 Close windows or doors.
 This is normal due to refrigerant rushing
through the coil. Frost will usually disappear within 60 minutes. This happens
when the appliance is operating in low
temperatures less than 53°F .
 The appliance will not operate satisfactorily if the room temperature is below 41°F.
 Shut off the appliance and let it sit on level surface for at least 6 hours.
TROUBLESHOOTING
Many common portable dehumidifiers problems are easily resolved. Try the troubleshooting suggestions
below to see if the problems can be resolved before having to contact the service department.
Problem
The dehumidifier leaks.
The dehumidifier does not
operate.
Possible Causes
Solutions
 Continuous/gravity drain hose
is loose.
 Cracked drain bucket.
 Secure the drain hose.
 Power failure or outage.
 The automatic switch, line
fuse, or breaker has been
tripped.
 Restore the power supply.
 Flip the switch / change the fuse / turn the
breaker back on. Also note that you may
have too many appliances drawing power
on one circuit, you may need to move the
other appliances to another circuit.
 Move the appliance onto another circuit
with the correct voltage.
 Call for service. Only authorized personnel should replace damaged power cord
or power plug.
 If you want to remove more moisture, set
the unit on Continuous operation.
 Empty drain bucket and insert the bucket
to the appliance properly.
 The power supply voltage is
too low.
 The power cord is damaged.
 The dryness level you selected has been reached.
 Drain bucket is full or not
positioned properly.
 Contact Whynter Service Department.
The pump indicator light
blinks.
 Water pump filter is dirty
 Water pump drain hose is obstructed or kinked.
 Clean the filter of the pump.
 Make sure that the water pump drain
hose is not obstructed .
Water on floor.
 Drain bucket is not installed
properly.
 Drain hose connection may be
loose or not installed properly.
 Install the drain bucket securely.
18
 Make sure that the drain hose is securely
installed in the drain outlet.
 For Drain Bucket method, make sure that
the continuous drain assembly is not installed and rubber drain cover is in place.
 For Continuous/Gravity Drain method and
Water Pump method, make sure the hose
is securely fastened to prevent leakage.
Direct the drain hose toward a drain or
other suitable drainage outlet.
ONE YEAR LIMITED WARRANTY
This WHYNTER portable dehumidifier is warranted, to the original owner within the 48 continental states, for one
year from the date of purchase against defects in material and workmanship under normal use and service.
Should your WHYNTER portable dehumidifier prove defective within one year from the date of purchase, return
the defective part or appliance, freight prepaid (within two months of purchase; after two months to one year, customer will be responsible for freight cost to Whynter’s service department), along with an explanation of the claim
to Whynter LLC. Please package the portable dehumidifier carefully in its original packaging material to avoid
damage in transit. Please retain the original box and packaging material. Under this warranty, Whynter will repair
or replace any parts found defective. This warranty is not transferable. After the expiration of the warranty, the
cost of labor and parts will be the responsibility of the original owner of the appliance.
THIS WARRANTY DOES NOT COVER:
 Acts of God, such as fire, flood, hurricanes, earthquakes and tornadoes.
 Damage, accidental or otherwise, to the portable dehumidifier while in the
possession of a consumer not caused by a defect in material or workmanship;
 Damage caused by consumer misuse, tampering, or failure to follow the
care and special handling provisions in the instructions.
 Damage to the finish of the case, or other appearance parts caused by wear.
 Damage caused by repairs or alterations to the product by anyone other
than authorized by the manufacturer.
 Freight and Insurance cost for the warranty service.
DISCLAIMER OF IMPLIED WARRANTIES; LIMITATION OF REMEDIES
CUSTOMER'S SOLE AND EXCLUSIVE REMEDY UNDER THIS LIMITED WARRANTY SHALL BE PRODUCT
REPAIR OR REPLACEMENT AS PROVIDED HEREIN. CLAIMS BASED ON IMPLIED WARRANTIES, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED TO
ONE YEAR OR THE SHORTEST PERIOD ALLOWED BY LAW, BUT NOT LESS THAN ONE YEAR. WHYNTER
SHALL NOT BE LIABLE FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SUCH AS PROPERTY DAMAGE
AND INCIDENTAL EXPENSES RESULTING FROM ANY BREACH OF THIS WRITTEN LIMITED WARRANTY
OR ANY IMPLIED WARRANTY. SOME STATES AND PROVINCES DO NOT ALLOW THE EXCLUSION OR
LIMITATION OF INCIDENTAL OR CONSE- QUENTIAL DAMAGES, OR LIMITATIONS ON THE DURATION OF
IMPLIED WARRANTIES, SO THESE LIMITATIONS OR EXCLUSIONS MAY NOT APPLY TO YOU. THIS WRITTEN WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS. YOU MAY ALSO HAVE OTHER RIGHTS THAT
VARY FROM STATE TO STATE.
To obtain service or information, contact
Whynter LLC via email at [email protected] or call
866-WHYNTER.
Product contents and specifications may change without notice.
Copyright © 2014 Whynter LLC
19