Download AirStage ARXC36L Specifications

Transcript
Meeting Various Needs with
the FUJITSU GENERAL VRF AIRSTAGE Series
The AIRSTAGE J-II Series adopts the best technology and was designed with the greatest care to provide not only
energy savings and comfort but also ease of design, installation, and maintenance. Fujitsu General provides air
conditioning systems for a wide range of applications from small office buildings and stores to large houses.
OUTDOOR UNITS
Various Line-up
for each buildings
4HP
5HP
6HP
AJ*A36LALH
AJ*A45LALH
AJ*A54LALH
AJ* : AJY (FUJITSU), AJH (GENERAL)
Building owners
Installers
End users
Service and
Management companies
Wide lineup of indoor units and controllers to support a variety of properties.
INDOOR UNITS
02
Compact Cassette
Cassette
Compact Duct
Slim Duct
(Drain Pump internal)
Low Static Pressure Duct /
Duct
High
Static Pressure Duct
Floor / Ceiling
Ceiling
Compact Wall Mounted
(EEV internal / EEV external)
Wall Mounted
Small Office
Large Homes
CONTROLLERS
Central Controller
Central
Remote Controller
Individual Controller
Group
Remote Controller
Touch Panel
Controller
System Controller
(Software)
Wireless
Remote Controller
Simple
Remote Controller
Wired
Remote Controller
03
FEATURES
Efficiency in actual operation
The building load is the range of almost 40 % to 80%. Therefore, most air conditioners do not operate at maximum load, but operate at low to
medium loads. Especially, for multi system, operation performance at partial load is important because all the air conditioners do not always
operate all the time. Aiming at energy saving performance matched to actual operation, Fujitsu General has developed a high intermediate
performance air conditioner corresponding not only to the rated performance at 100% load, but also to low to medium load
Load curve (a typical office building)
Building load (%)
100
80
60
40
20
0
0
3
6
9
12
15
18
21
24
Time (h)
High EER / COP
4.53
High part load performance (6HP class)
4.20
4.00
3.60
3.95
3.45
66 %
UP
4 HP
: EER
5 HP
: COP
6 HP
50%
5.73
100%
3.45
EER
Cooling part load
04
46 %
UP
50%
5.75
100%
3.95
COP
Heating part load
Conditions : Connected indoor units: AUXA30LALH+AUXD24LALH
Cooling : indoor temp. of 27°CDB / 19°CWB, outdoor temp. of 35°CDB / 24°CWB
Heating : indoor temp. of 20°CDB / 15°CWB, outdoor temp. of 7°CDB / 6°CWB
Large propeller fan
DC inverter control
High performance and low noise
realized by large propeller and
optimization of angle.
Efficiency is improved by
mounting of new active filter
module.
DC fan motor
Miniaturized, low noise, high
efficiency, multi-stage DC fan motor
is mounted.
Subcool heat exchanger
Pressure
Cooling performance is
improved by mounting of dual
tube heat exchanger.
effect
Large heat exchanger
Heat exchange performance is
substantially improved by mounting
of 3-row large heat exchanger.
Optimized refrigerant flow design
Highly accurate parts
Enthalpy
DC twin rotary compressor
Efficiency in all load regions is good.
Especially good performance from low to
medium at normal operation.
High
Compressor
efficiency
High efficiency compressor motor
Cooling performance improved
DC Twin Rotary compressor
Compressor capacity
High
05
FEATURES
Operation Performance is Efficiently Controlled.
Room temperature set point limitation
Economy operation
The minimum and maximum temperature range can be set.
The temperature setting is offset automatically over a
certain period of time.
Heating
(°C)
Cooling
30
Set Temp.
Down
Heating Set Temperature
MAX. - 4°C
28
Down
Down
Down
Economy operation
Control Temperature
26
Economy operation
24
Set Temp.
22
Economy operation
Economy operation
Control Temperature
20
18
MAX. +2°C
Cooling Set Temperature
16
Up
Up
14
12
10
Original
Set Temp.
Set point
limitation setting
Capacity save operation
The power consumption at peak is cut down.
Setting
range
80%
Capacity
Capacity save
Setting
level
60%
40%
0%
Central Remote Controller
Time
Wasteful Operation is Prevented.
Auto Off function
This prevents waste of energy.
OFF OFF OFF
18:00
06
20:00
22:00
Heating
capacity
(kW)
Powerful Heating
Heating capacity is improved at low outdoor
temperature by our advanced technology.
J-II series (6HP)
16.6
33%
Current model (6HP class)
UP !
-20
-10
0
7
Outdoor temperature (°C)
Low Noise Design
Low noise design of outdoor unit
Low noise mode
Significantly reduced noise by optimized
airflow structure design of outdoor unit.
Outdoor unit can be switched to silent mode,
depending on the installation environment.
Current model
56dB
J-II series
(4~ 6HP)
53dB
Noise
level
Rated noise value
-5dB ~ -6dB
Low noise mode
6HP class (Cooling)
Time
Various Comfort Control Function
Easy auto changeover function
Non-stop oil recovery operation
Auto louver grill (Option for Slim Duct)
At the auto mode, cooling and heating
mode is switched automatically to
maintain the setting temperature.
The product continues to operate without
stopping the cooling or heating operation
during oil recovery modes.
Auto louver grille provides comfort and
efficient heating with louver controlled
ductable outlet
Temp.
(°C)
Cooling operation
Heating
operation
With Auto Louver
Set Temp.
J-II series
35
ON
30
Operation stopped at oil recovery
Heating operation
Function setting is required.
1 indoor unit (Master) can apply this function.
Current
model
Time
ON
25
20
OFF
Temperature(°C)
40
15
Time
07
FEATURES
Central Control of Small Office, Shop, etc.
Building Management
System
A/C
central controller
Convertor for
BMS Control
Network Convertor
for LONWORKS ®
UTY-VLGX
Network
Convertor
UTY-VGGX
BACnet ® Gateway
(Software)
Group
Remote Controller
UTY-CGG*
UTY-ABGX
Max. controllable
18 indoor units
Lighting facilities
Ventilation system
Central
Remote Controller
Security system
UTY-DCG*
Max. controllable
100 indoor units
Touch Panel
Controller
UTY-DTG*
Max. controllable
400 indoor units
System
Controller (Software)
UTY-APGX
Max. controllable
1,600 indoor units
G*: GY (FUJITSU), GG (GENERAL)
Control system composition example
VRF network system
Building control
computer
Central
Remote Controller
or
Network Convertor
for LONWORKS ®
System Controller
(Software)
BACnet ® Gateway
(Software)
08
Touch Panel
Controller
Network
Convertor
Group
Remote Controller
Individual and Central Control of Large Homes
Central Remote Controller
Wireless Remote Controller
Wired Remote Controller
UTY-LNH*
UTY-RNK*
UTY-DCG*
• Automatic display of number
of connected indoor unit
• Max. controllable
100 units
or
Group Remote Controller
UTY-CGG*
Simple Remote Controller
• Max. controllable
18 indoor units
UTY-RSK*
UTY-RHK*
With operation mode
Without operation mode
K*: KY (FUJITSU), KYT (FUJITSU), KG (GENERAL)
H*: HY (FUJITSU), HG (GENERAL)
G*: GY (FUJITSU), GG (GENERAL)
Control system composition example
Central
Remote Controller
or
Wired
Remote Controller
Group
Remote Controller
Wired
Remote Controller
+
Simple
Remote Controller
Simple
Remote Controller
IR Receiver Unit
+
Wireless
Remote Controller
Wireless
Remote Controller
Wired
Remote Controller
+
Wireless
Remote Controller
09
FEATURES
Long Piping Length
Our advanced refrigerant control technology allows us to achieve a total refrigerant
piping length of 180 m. This opens up new possibilities in system design.
Actual piping length
Height difference between outdoor
120 m max.
and indoor units
Piping length from
first separation tube to
the farthest indoor unit
Height difference between indoor
and indoor units
30 m max.
15 m max.
40 m max.
Total piping length
180 m max.
High Capacity Connection
Number of connectable indoor unit
4 HP
2 to 6 units
Indoor unit
5HP
2 to 8 units
6 HP
2 to 9 units
Wide operating range
Installation in extreme temperature
conditions is possible due to an
increase in operational range.
Cooling : -5°C~46°C
Heating : -20°C~21°C
12 types,
52 models
(°C)
50
40
Heating
21°C
30
20
10
-20°C area
Operation possible
in heating.
0
-10
-20
10
Cooling
46°C
-5°C
-20°C
Connectable
indoor unit
capacity range
130 % max.
Easier Installation
Easy piping connection
Flexible installation of outdoor unit
Improvement of the reliability by decreasing the flare connection.
Corresponds to the outdoor unit concentration
installation.
Flare connection
J-II series
Previous model
EV kit
Terminal box
Power supply cable
Flare
connection
Reduced installation intervals
by front access
Power supply
(Indoor )
Power supply
(Outdoor )
Easy wiring connection
• Decreasing wiring mistakes by using non-polar 2 wires.(Remote controller cable is 3 wires)
Flexible installation by
4 way pipe direction
• Improvement of wiring installation by common with V-II power supply method.
Convenient Commissioning Support
Automatic address setting function
Connection check function
The address of each indoor unit can be automatically set by button switch of
outdoor unit.
Possible to confirm whether wiring connection and
address setting are correct by check run function for
a short time.
3
7
1
0
2
4
5
6
• Display connected indoor unit numbers
• Duplicately set address number of
indoor unit can be displayed
Press the push button
of outdoor unit.
Easy to connect
with V-II communication system
J-II system
V-II system
Connects without a converter
It is possible to connect directly with the transmission cable of
the V-II system without convertor.
11
FEATURES
Design for Easy Maintenance
Easy to read 7-segment LED
Confirm detail operational and trouble status without using specific equipment
Error status can be checked easily via
the indoor unit wired controller
An error code is displayed on a liquid crystal
screen.
Wired Remote Controller
Faulty unit number (Remote controller address)
Error code
7-segment LED
SU MO TU WE TH FR SA
Simple Remote Controller
Remote controller address
Error code
Movable PCB panel
Easier for maintenance work behind
the PCB
Emergency Stop Function
Emergency alarm can be received by indoor, outdoor
units, Central Remote Controller or Touch Panel
Controller when they received it, all units will be
stopped.
Note : In case of received Emergency alarm by Indoor /
outdoor unit : All units connected within same refrigerant
system will be stopped.
Central Remote Controller or Touch Panel Controller : all units
connected within VRF network system with Central Remote
Controller or Touch Panel Controller will be stopped.
Central
Remote Controller
or
Emergency
stop function
Touch
T
hP
Panell
Controller
Trouble diagnosis by Service Tool
Emergency
stop function
Emergency
stop function
Transmission cable
(Non-polar 2 wires)
Connection to Service Tool
• Detail operation status and recent
error history can be checked and
analyzed by using Service Tool.
Service Tool
UTY-ASGX
• Last 5 min. operation memory can
be also recorded.
USB adaptor
(Field supplied)
Equipment Detail (Diagram)
12
Software
OUTDOOR UNITS
Specifications
AJ*A36LALH
Model name
Capacity range
HP
Maximum connectable indoor unit
AJ*A45LALH
AJ*A54LALH
4
5
6
6
8
9
Power source
1Ø, ~ 230 V, 50 Hz
11.2
14.0
Heating
12.5
16.0
18.0
Cooling
2.80
3.89
4.49
4.56
Cooling
Capacity
Input power
kW
kW
15.5
Heating
2.76
3.81
EER
Cooling
4.00
3.60
3.45
COP
Heating
4.53
4.20
3.95
6,200
6,400
6,900
50
51
53
52
53
55
Air flow rate
W/W
m 3/h
High
Cooling
Sound pressure level
dB(A)
Heating
Heat exchanger fin
Blue fin
mm
Dimensions (H×W×D)
Weight
kg
Refrigerant charge
kg
Liquid
Connection pipe diameter
1,334 x 970 x 370
117
4.8
5.3
9.52
mm
Gas
15.88
Cooling
Operation range
19.05
-5 to 46
°CDB
Heating
-20 to 21
Note : Specifications are based on the following conditions.
Cooling : Indoor temperature of 27°CDB / 19°CWB, and outdoor temperature of 35°CDB / 24°CWB.
Heating : Indoor temperature of 20°CDB / (15°CWB), and outdoor temperature of 7°CDB / 6°CWB.
Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m.
The protective function might work when using it outside the operation range.
AJ* : AJY (FUJITSU), AJH (GENERAL)
Dimensions
166
650
154
AJ*A36LALH / AJ*A45LALH / AJ*A54LALH
32
(410)
40
51(Gas)
370
43(Liquid)
(Unit : mm)
36
970
32
370
12
Terminal blocks (Transmission)
907
3-Way valve (Liquid)
1000
1334
Terminal blocks (Power)
21
Ø28 (Cable port)
Ø28 (Cable port)
Pipe port
55
A
Detail
21
65
Ø28 (Cable port)
Ø28 (Cable port)
Pipe port
A
50
14
15
50
142
155
120
50
25
95
50
le port)
131
87
21
Ø28 (Cab
Pipe port
65
227
341
305
89
279
((Liquid valve))
297
(Gas valve)
le port)
ab
Ø28 (C
70
111
3-Way valve (Gas)
50
438
Pipe & cable port
13
622
AJ* : AJY (FUJITSU), AJH (GENERAL)
INDOOR UNIT
Indoor Unit Lineup
12 Types, 52 Models, Capacity range from 2.2kW to 14.0kW
Capacity range (kW)
Model code
2.2
2.8
3.6
4.5
7
9
12
14
AUXB07LALH
AUXB09LALH
AUXB12LALH
AUXB14LALH
ARXB07LALH
ARXB09LALH
ARXB12LALH
ARXB14LALH
ARXD07LATH
ARXD09LATH
ARXD12LATH
ARXD14LATH
AB*A12LBTH
AB*A14LBTH
AS*A09LACH
AS*A12LACH
AS*A14LACH
AS*E09LACH
AS*E12LACH
AS*E14LACH
Compact Cassette
Cassette
Compact Duct
Slim Duct
(Drain pump internal)
Low Static Pressure Duct
Duct
High Static Pressure Duct
Floor / Ceiling
Ceiling
Compact Wall Mounted
(EEV internal)
AS*A07LACH
Compact Wall Mounted
(EEV external)
AS*E07LACH
With this model, connection of EV kit is necessary
Wall Mounted
* : Y(FUJITSU), H(GENERAL)
14
Comprehensive range of indoor units of variety design and capacity ranges
available which can be selected to suit any air conditioning needs.
5.6
7.1
9.0
11.2
12.5
14.0
18
24
30
36
45
54
AUXB18LALH
AUXB24LALH
AUXD18LALH
AUXD24LALH
AUXA30LALH
AUXA36LALH
AUXA45LALH
AUXA54LALH
ARXB24LATH
ARXB30LATH
ARXB36LATH
ARXB45LATH
ARXA24LATH
ARXA30LATH
ARXA36LATH
ARXA45LATH
ARXC36LATH
ARXC45LATH
AB*A36LBTH
AB*A45LBTH
ARXB18LALH
ARXD18LATH
AB*A18LBTH
ARXD24LATH
AB*A24LBTH
AB*A30LBTH
AS*A18LACH
AS*A24LACH
AB*A54LBTH
AS*A30LACH
15
INDOOR UNIT
Compact Cassette
AUXB07LALH
AUXB14LALH
AUXB09LALH
AUXB18LALH
AUXB12LALH
AUXB24LALH
Grille is an option
Powerful wide air flow & Quiet operation
High efficiency 2-stage turbo fan
2-stage turbo fan
Previous turbo fan
1-stage
A evenly spread air distribution across
the heat exchanger is possible due to
the new 2 stage turbo fan which
produces two separate airflow streams.
In the case of a conventional fan,
the air outlet range was
narrow as the airflow moved to the
motor side which meant the
velocity of air passing through
the heat exchanger was uneven.
+
2-stage
2 stage
Heat exchange
efficiency:
20
%UP
Wind velocity
Fast
Slow
Quiet quality
High lift drain pump
Optimization of wing form (laminar wing type) and wing number
(7 blades each)
Ceiling panel
Height
700mm
Designed by CFD-analysis (fluid) simulations
Quiet
Laminar wing
Airflow runs through smoothly along
the laminar wing
No airflow separation
Quiet
Optional parts
Adoption of laminar wing
Spin direction
Air Outlet Shutter Plate:
UTR-YDZB
Fresh Air Intake Kit:
UTZ-VXAA
Insulation Kit For High Humidity: UTZ-KXGC
Airflow direction
Specifications
AUXB07LALH
Model No.
Power source
Cooling
Capacity
Heating
Input power
kW
W
High
Air flow rate
Med
Sound pressure level
m3/h
2.2
2.8
3.6
4.5
5.6
7.1
2.8
3.2
4.1
5.0
6.3
8.0
25
25
29
35
36
84
540
550
600
680
710
1,030
450
530
590
580
830
350
350
390
390
400
450
High
34
35
37
38
41
50
30
30
34
34
35
44
25
25
27
27
27
30
Med
dB(A)
mm
kg
Weight
Liquid (Flare)
Gas (Frare)
mm
mm
kg
Note : Specifications are based on the following conditions.
16
15
17
ø6.35
ø9.52
ø12.70
ø15.88
UTG-UFYC-W (FUJITSU brand); UTG-UFGC-W (GENERAL brand)
Model name
Dimensions (H x W x D)
245 x 570 x 570
ø25 (I.D) ; ø32 (O.D.)
Drain
Weight
AUXB24LALH
450
Dimensions (H x W x D)
Grille
(option)
AUXB18LALH
1Ø, 230V ~, 50Hz
Low
Low
Connection
pipe diameter
AUXB14LALH
AUXB12LALH
AUXB09LALH
V/ø/Hz
50 x 700 x 700
2.6
Cooling : Indoor temperature of 27°CDB / 19°CWB, and outdoor temperature of 35°CDB / 24°CWB.
Heating : Indoor temperature of 20°CDB / (15°CWB), and outdoor temperature of 7°CDB / 6°CWB.
Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m.
Cassette
AUXD18LALH
AUXA36LALH
AUXD24LALH
AUXA45LALH
AUXA30LALH
AUXA54LALH
Grille is an option
Powerful, wide airflow and quiet operation
High efficiency turbo fan with 3-dimensional blade
High efficiency airflow distribution has been achieved by the introduction of a 3
dimensional blade which increases the air passing over the heat exchanger.
Previous turbo fan
Air passing through the heat exchanger was uneven and the air would only
flow close to the ceiling.
450mm
500mm
Previous blade
3-dimensional
blade
Heat exchanger
< Motor side >
Heat exchanger
Separation
phenomenon of
airflow
causes noise
< Motor side >
Wind velocity
Fast
Quiet
No airflow separation
Uneven airflow
Slow
: Spin direction
: Airflow direction
: Turbulent flow noise
Improvement of the airflow distribution
The louvre design distributes air
leaving a space between the
chassis and the ceiling allowing far
and wide air flow distribution.
Front part
Optional parts
Ceiling
Bottom view
Rear part
Much less temperature irregularity
happens by spreading airflow widely
Round louvre
IR Receiver Kit :
Air Outlet Shutter Plate :
Panel Spacer :
Insulation Kit for High Humidity :
Wide Panel :
Fresh Air Intake Kit :
UTY-LRH*B1
UTR-YDZC
UTG-BGYA-W
UTZ-KXGA / UTZ-KXGB
UTG-AGYA-W
UTZ-VXGA
H* : HY(FUJITSU), HG(GENERAL)
Specifications
AUXD18LALH
Model No.
Power source
Cooling
Capacity
Heating
Input power
kW
W
High
Air flow rate
Med
Sound pressure level
AUXD24LALH
m3/h
AUXA54LALH
5.6
7.1
9.0
11.2
12.5
14.0
6.3
8.0
10.0
12.5
14.0
16.0
39
46
59
80
99
119
1,150
1,280
1,600
1,800
1,900
2,000
1,040
1,300
1,300
1,370
1,370
870
870
1,100
1,100
1,100
1,100
High
36
38
40
44
46
47
30
33
38
38
39
39
29
29
33
33
33
33
Med
Weight
dB(A)
mm
246 x 840 x 840
kg
23
288 x 840 x 840
27
Liquid (Flare)
Gas (Frare)
ø9.52
mm
UTG-UGYA-W (FUJITSU brand); UTG-UGGA-W (GENERAL brand)
Model name
Dimensions (H x W x D)
ø19.05
ø15.88
ø25 (I.D.) ; ø32 (O.D.)
Drain
Weight
AUXA45LALH
940
Dimensions (H x W x D)
Grille
(option)
AUXA36LALH
1Ø, 230V ~, 50Hz
Low
Low
Connection
pipe diameter
AUXA30LALH
V/ø/Hz
mm
kg
Note : Specifications are based on the following conditions.
50 x 950 x 950
5.5
Cooling : Indoor temperature of 27°CDB / 19°CWB, and outdoor temperature of 35°CDB / 24°CWB.
Heating : Indoor temperature of 20°CDB / (15°CWB), and outdoor temperature of 7°CDB / 6°CWB.
Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m.
17
INDOOR UNIT
Compact Duct
ARXB07LALH
ARXB14LALH
ARXB09LALH
ARXB18LALH
ARXB12LALH
Small and compact indoor unit suitable for many applications
Low noise level
Low static pressure
mode
Model
7
Static pressure
range
Pa
Noise level
(Low speed)
dB(A)
9
12
14
18
30
30
0 to 50
24
27
25
Normal mode
Airflow drop
prevention
Airflow
A low noise level has been achieved for each capacity
Low noise
realized
Static pressure (Pa)
Compact design
Flexible installation
Ultra-slim duct air conditioner for easy installation
Floor concealed
Ceiling concealed
Height
217mm
Slim size (217mm) allows installation even where the space
behind the ceiling is narrow.
Air-intake
Optional parts
Bottom side
Back side
Air-intake at back side makes it possible to reduce the noise effectively.
Remote Sensor Unit : UTD-RS100
IR Receiver Unit :
UTB-*WC
Drain Pump Unit :
UTZ-PX1BBA
*WC : YWC, TWC
Specifications
ARXB07LALH
Model No.
Power source
Cooling
Capacity
Heating
Input power
kW
W
High
Med
Air flow rate
m3/h
Low
Static pressure range
Pa
Standard static pressure
High
Sound pressure level
ARXB09LALH
*1
Med
dB(A)
Low
Dimensions (H x W x D)
Weight
Gas (Frare)
ARXB18LALH
2.2
2.8
3.6
4.5
5.6
2.8
3.2
4.0
5.0
6.3
46
55
63
90
96
370
440
590
800
890
310
370
500
750
810
280
340
450
700
730
0 to 50
0 to 50
0 to 50
0 to 50
0 to 50
25
25
25
25
25
29
31
30
33
36
26
29
28
32
34
24
27
25
30
30
mm
217 x 663 x 595
kg
18
mm
Drain
18
ARXB14LALH
1Ø, 230V ~, 50Hz
Liquid (Flare)
Connection
pipe diameter
ARXB12LALH
V/ø/Hz
Note : Specifications are based on the following conditions.
Cooling : Indoor temperature of 27°CDB / 19°CWB, and outdoor temperature of 35°CDB / 24°CWB.
Heating : Indoor temperature of 20°CDB / (15°CWB), and outdoor temperature of 7°CDB / 6°CWB.
Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m.
217 x 953 x 595
25
ø6.35
ø9.52
ø12.70
ø15.88
ø25 (I.D.) ; ø32 (O.D.)
*1: For the air-intake at bottom, the operation noise is larger than the value
mentioned in the above table.
Slim Duct
ARXD07LATH
ARXD14LATH
ARXD09LATH
ARXD18LATH
ARXD12LATH
ARXD24LATH
•Slim design with drain pump •Increase static pressure range
Slim design
Auto Louver Grille Kit (Option)
This model is slim design, it can install at the
place where a ceiling is narrow.
Simple flat Auto Louver will provide comfort airflow and harmonize
with luxury interior.
Auto Louver
Grille
Drain port
Slim Duct
Height
198mm
Drain pump built-in
Drain pump
Air-intake
Wired Remote
Controller
Air intake direction can be selected to match the installation site.
Wireles Remote
Controller
Flexible installation
Back side
Bottom side
Floor concealed
Ceiling concealed
Depending on the installation site, air-intake at back side makes
it possible to reduce the noise effectively.
Selectable wide range static pressure
Static pressure
range
0 to 90 Pa
24 model is 0 to 50Pa
External Static Pressure[Pa]
By using DC fan motor, it is possible to change the static pressure
range 0 to 90Pa. The change of static pressure range is possible by
remote controller.
120
Available air flow rate range @ Hi speed
(ARXD12LATH)
60
0
400
Optional parts
IR Receiver Unit:
Remote Sensor Unit:
Auto Louver Grille Kit
Normal
11 steps
500
600
Air Flow [m3/h]
700
UTB-*WC
UTD-RS100
UTD-GXSA-W (for ARXD07/09/12/14LATH)
UTD-GXSB-W (for ARXD18LATH)
UTD-GXSC-W (for ARXD24LATH)
800
*WC : YWC, TWC
Specifications
ARXD07LATH
Model No.
Power source
Cooling
Capacity
Heating
Input power
kW
W
High
Med
Air flow rate
m3/h
Low
Static pressure range
Pa
Standard static pressure
High
Sound pressure level
*1
Med
dB(A)
Low
kg
Weight
Liquid (Flare)
Connection
pipe diameter
Gas (Frare)
ARXD24LATH
7.1
2.2
2.8
3.6
4.5
5.6
2.8
3.2
4.0
5.0
6.3
8.0
44
50
54
92
83
122
550
600
600
800
940
1,330
490
550
510
710
840
1,240
440
480
450
610
750
1,100
0 to 90
0 to 90
0 to 90
0 to 90
0 to 90
0 to 50
25
25
25
25
25
25
28
29
30
34
34
35
25
26
27
32
32
32
22
24
24
28
28
29
198 x 900 x 620
198 x 1,100 x 620
198 x 700 x 620
18
19
ø15.88
ø12.70
Drain
Note : Specifications are based on the following conditions.
Cooling : Indoor temperature of 27°CDB / 19°CWB, and outdoor temperature of 35°CDB / 24°CWB.
Heating : Indoor temperature of 20°CDB / (15°CWB), and outdoor temperature of 7°CDB / 6°CWB.
Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m.
27
23
ø9.52
ø6.35
mm
ARXD18LATH
1Ø, 230V ~, 50Hz
mm
Dimensions (H x W x D)
ARXD14LATH
ARXD12LATH
ARXD09LATH
V/ø/Hz
ø25 (I.D.) ; ø32 (O.D.)
*1: For the air-intake at bottom, the operation noise is larger than the value
mentioned in the above table.
19
INDOOR UNIT
Low Static Pressure Duct/Duct
Low Static Pressure Duct
Duct
ARXB24LATH
ARXA24LATH
ARXB30LATH
ARXA30LATH
ARXB36LATH
ARXA36LATH
ARXB45LATH
ARXA45LATH
Airflow
Line-up of low-noise and
high-power models, compatible with
a wide range of static pressure
Two-direction drain piping
Duct type
Duct indoor unit
Two-direction drain piping
Low Static Pressure
Duct type
0
Static pressure
Easy maintenance
See below for the case of rear suction type
Low Static Pressure Duct type
New model
Previous model
Optimum model for hotels
or bedrooms
1
1
3
4
4
An ultra low-noise model that achieves a quiet
interior. Perfect for hotels or bedrooms with
limited air duct installation space. Two different
levels can be selected according to the static
pressure range.
29dB
1.Control box
2.Fan casing
3.Fan
4.Motor
3
2
2
Bottom panel: 2 pieces
ARXB30
Low
Large bottom
panel: 1 piece
Duct type
Powerful model
with a flexible design
Optional parts
With a powerful motor, appropriate for a wide
range of static pressure. Flexible air duct
installation is possible in a large space such as
an office.
Max.
Remote Sensor Unit : UTD-RS100
Long-Life Filter :
UTD-LF25NA
Flange (Square) :
UTD-SF045T
150Pa
Flange (Round) : UTD-RF204
IR Receiver Unit : UTB-*WC
Drain Pump Unit : UTZ-PX1NBA
*WC : YWC, TWC
Specifications
ARXB24LATH
Model No.
Power source
Cooling
Capacity
Heating
Input power
kW
W
High
Air flow rate
Med
m3/h
Low
Static pressure range
Pa
Standard static pressure
High
Sound pressure level
ARXB30LATH
V/ø/Hz
Med
dB(A)
Low
kg
Weight
Gas (Frare)
ARXA30LATH
ARXA36LATH
ARXA45LATH
1Ø, 230V ~, 50Hz
9.0
11.2
12.5
7.1
9.0
11.2
12.5
10.0
12.5
14.0
8.0
10.0
12.5
14.0
145
198
253
338
190
188
312
312
1,100
1,410
1,710
1,970
1,280
1,280
1,720
1,720
920
1,280
1,600
1,790
1,210
1,210
1,670
1,670
810
1,150
1,470
1,670
1,130
1,130
1,600
1,600
0 to 80
0 to 80
0 to 80
0 to 80
30 to 150
30 to 150
30 to 150
30 to 150
40
50
50
60
100
100
100
100
31
34
37
41
38
40
43
43
27
32
35
38
36
38
41
41
25
29
33
36
34
36
39
39
270 x 1,135 x 700
270 x 1,135 x 700
45
43
45
43
ø9.52
ø9.52
mm
Drain
Note : Specifications are based on the following conditions.
20
ARXA24LATH
8.0
Liquid (Flare)
Connection
pipe diameter
ARXB45LATH
7.1
mm
Dimensions (H x W x D)
ARXB36LATH
1Ø, 230V ~, 50Hz
ø15.88
ø19.05
ø25 (I.D.) ; ø32 (O.D.)
ø15.88
ø19.05
ø25 (I.D.) ; ø32 (O.D.)
Cooling : Indoor temperature of 27°CDB / 19°CWB, and outdoor temperature of 35°CDB / 24°CWB.
Heating : Indoor temperature of 20°CDB / (15°CWB), and outdoor temperature of 7°CDB / 6°CWB.
Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m.
High Static Pressure Duct
ARXC36LATH
ARXC45LATH
These indoor units allow for high airflow quantities
Low noise design
Cutting off the corners of the conventional indoor unit front panel
and fan casing, has enabled less turbulent air flow. Low noise is
realized by adopting a plastic case and a plastic fan.
Easy installation
(Compact size & Lightweight)
A compact size and lightweight
indoor unit has been developed by
reducing the basic chassis and the
overall material weight.
Volume
Weight
47.5%
40%
down
down
(unit: mm)
1,050
New model
(ARXC36L)
Previous model
500mm
400
400
ARXC36L : 45kg
800mm
Metal fan
ø240mm
Previous model : 75kg
Heat exchanger
400mm
Heat
exchanger
800
400mm
Plastic fan
ø225mm
1,250
500
Casing (Metal Sheet)
Casing (Plastic)
Previous model:
Metal fan [53.1dB(A)]
New model:
Plastic fan [45dB(A)]
(At 100Pa : Actual noise measurement value)
45dB(A)
ARXC36L
Optional parts
Long-Life Filter :
UTD-LF60KA
IR Receiver Unit :
UTB-*WC
Remote Sensor Unit : UTD-RS100
*WC : YWC, TWC
Specifications
ARXC36LATH
Model No.
Power source
Cooling
Capacity
Heating
Input power
kW
W
High
Air flow rate
Med
m3/h
Low
Static pressure range
Pa
Standard static pressure
High
Sound pressure level
Med
dB(A)
12.5
14.0
405
427
2,600
3,500
1,950
3,000
1,450
2,460
100 to 200
100 to 250
100
100
45
49
38
45
mm
kg
Weight
Liquid (Flare)
Connection
pipe diameter
11.2
12.5
Gas (Frare)
42
32
Low
Dimensions (H x W x D)
ARXC45LATH
1Ø, 230V ~, 50Hz
V/ø/Hz
400 x 1,050 x 500
45
47
ø9.52 (Flare)
mm
Drain
Note : Specifications are based on the following conditions.
ø19.05 (Flare)
ø25 (I.D.) ; ø32 (O.D.)
Cooling : Indoor temperature of 27°CDB / 19°CWB, and outdoor temperature of 35°CDB / 24°CWB.
Heating : Indoor temperature of 20°CDB / (15°CWB), and outdoor temperature of 7°CDB / 6°CWB.
Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m.
21
INDOOR UNIT
Floor / Ceiling Type
AB*A12LBTH
AB*A14LBTH
AB*A18LBTH
AB*A24LBTH
The slim and lightweight design allow the unit to be suspended
from the ceiling or installed on the floor. This type suits many room designs
Flexible installation
Easy maintenance
Example for floor installation
Example for ceiling installation
Floor console
Under ceiling
Double auto swing
High power DC fan motor
A combination of up/down and right/left directional swing
allows three-dimensional air direction control.
• High power
• Wide rotation range
• High efficiency
RIGHT and LEFT SWING
UP and DOWN SWING
3
2
1
4
1
5
2
Compact design
3
4
Symmetrical, slim and
compact design.
5 steps selectable
655
4 steps selectable
990
199
(Unit : mm)
Specifications
AB*A12LBTH
Model No.
Power source
Cooling
Capacity
Heating
Input power
kW
W
High
Air flow rate
Sound pressure level
Med
m3/h
AB*A24LBTH
3.6
4.5
5.6
7.1
4.0
5.0
6.3
8.0
30
42
74
99
660
780
1,000
1,000
570
640
720
820
490
550
580
680
High
36
40
46
47
32
36
39
42
28
34
35
37
Med
dB(A)
mm
Dimensions (H x W x D)
kg
Weight
Liquid (Flare)
Gas (Frare)
mm
Drain
AB* : ABY(FUJITSU), ABH(GENERAL)
Note : Specifications are based on the following conditions.
22
AB*A18LBTH
1Ø, 230V ~, 50Hz
Low
Low
Connection
pipe diameter
AB*A14LBTH
V/ø/Hz
199 x 990 x 655
27
25
ø6.35
ø9.52
ø12.70
ø15.88
ø25 (I.D.) ; ø32 (O.D.)
Cooling : Indoor temperature of 27˚CDB / 19˚CWB, and outdoor temperature of 35˚CDB / 24˚CWB.
Heating : Indoor temperature of 20˚CDB / (15˚CWB), and outdoor temperature of 7˚CDB / 6˚CWB.
Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m.
Voltage : 230 [V].
Ceiling Type
AB*A30LBTH
AB*A36LBTH
AB*A45LBTH
AB*A54LBTH
Easily concealed in any installation
Installation
Open
Concealed
Wall mounted
(Field Supplied)
General installation pattern
which suspends the indoor
unit from the ceiling.
Installation pattern where part
of the indoor unit is embedded
into the ceiling.
Installation which fixes the indoor unit to the
wall by the use of wall brackets (Field supplied).
This type of installation can be used
when the ceiling space is insufficient.
Double auto swing and wide airflow
Condensate lift-up mechanism (Option)
Auto airflow direction and auto swing
Optional drain
lift-up mechanism
allows flexible
installation.
Right and left
Max.
500mm
Fresh air intake
Up and down
5 steps selectable
Indoor
1
2
Optional parts
3
4
4 steps selectable
Drain Pump Unit : UTR-DPB24T
Flange :
UTD-RF204
Specifications
AB*A30LBTH
Model No.
Power source
Cooling
Capacity
Heating
Input power
kW
W
High
Air flow rate
Sound pressure level
Med
m3/h
AB*A45LBTH
AB*A54LBTH
1Ø, 230V ~, 50Hz
9.0
11.2
12.5
14.0
10.0
12.5
14.0
16.0
66
85
131
180
1,630
1,690
2,010
2,270
1,370
1,400
1,600
1,780
Low
1,140
1,170
1,230
1,280
High
42
45
48
51
38
38
42
45
33
34
35
36
Med
dB(A)
Low
mm
Dimensions (H x W x D)
kg
Weight
240 x 1,660 x 700
Gas (Frare)
48
47
Liquid (Flare)
Connection
pipe diameter
AB*A36LBTH
V/ø/Hz
ø9.52
mm
Drain
AB* : ABY(FUJITSU), ABH(GENERAL)
Note : Specifications are based on the following conditions.
ø19.05
ø15.88
ø25 (I.D.) ; ø32 (O.D.)
Cooling : Indoor temperature of 27˚CDB / 19˚CWB, and outdoor temperature of 35˚CDB / 24˚CWB.
Heating : Indoor temperature of 20˚CDB / (15˚CWB), and outdoor temperature of 7˚CDB / 6˚CWB.
Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m.
Voltage : 230 [V].
23
INDOOR UNIT
Compact Wall Mounted Type
EEV internal
EEV external
AS*A07LACH
AS*E07LACH
AS*A09LACH
AS*E09LACH
AS*A12LACH
AS*E12LACH
AS*A14LACH
AS*E14LACH
Simple design with energy saving.
Compact design
Air conditioner filter features
Long-life*
ion deodorization filter
New model
The filter deodorizes by powerfully decomposing absorbed odors
using the oxidizing and reducing effects of ions generated by the
ultra-fine-particle ceramic.
790mm
*The filter can be used for approx. 3 years if it is washed under water to restore its surface
action when it is dirty.
275mm
Apple-catechin filter
Fine dust, invisible mold spores, and harmful microorganisms are
absorbed onto the filter by static electricity, and further growth is
inhibited and deactivated by the polyphenol ingredient extracted
from apples.
215mm
Easy maintenance
More Comfort & Convenience
• Powerful cooling & heating by using DC fan motor
• Auto-restart function memorizes the operating mode as before,
once the power supply is restored.
• Comfortable timer (ON, OFF, PROGRAM, SLEEP)
Removable & washable panel
Specifications
AS*A07LACH
Model No.
Power source
V/ø/Hz
Cooling
Capacity
Heating
Input power
kW
W
High
Air flow rate
Sound pressure level
Med
m3/h
AS*A14LACH
AS*E07LACH
AS*E09LACH
AS*E12LACH
AS*E14LACH
1Ø, 230V ~, 50Hz
2.2
2.8
3.6
4.5
2.2
2.8
3.6
4.5
2.8
3.2
4.1
5.0
2.8
3.2
4.1
5.0
16
16
19
30
15
16
20
28
490
500
560
670
490
500
560
680
450
450
480
490
450
450
480
490
370
370
420
420
370
370
420
420
High
35
36
39
44
34
35
38
43
33
33
35
37
32
32
34
35
27
27
31
32
26
26
30
30
Med
dB(A)
mm
Dimensions (H x W x D)
kg
Weight
Liquid (Flare)
Gas (Frare)
mm
Drain
EV Kit (option)
AS* : ASY(FUJITSU), ASH(GENERAL)
Note : Specifications are based on the following conditions.
24
AS*A12LACH
1Ø, 230V ~, 50Hz
Low
Low
Connection
pipe diameter
AS*A09LACH
275 x 790 x 215
275 x 790 x 215
9
9
ø6.35
ø6.35
ø12.70
ø12.70
ø13.8(I.D.) ; ø15.8-ø16.7(O.D.)
ø13.8(I.D.) ; ø15.8-ø16.7(O.D.)
-
UTR-EV09XB
Cooling : Indoor temperature of 27°CDB / 19°CWB, and outdoor temperature of 35°CDB / 24°CWB.
Heating : Indoor temperature of 20°CDB / (15°CWB), and outdoor temperature of 7°CDB / 6°CWB.
Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m.
Voltage : 230 [V].
UTR-EV14XB
Wall Mounted Type
AS*A18LACH
AS*A24LACH
AS*A30LACH
Simple & Elegant Appearance Design
“Vertical airflow”
provides powerful floor level heating
Air conditioner filter features
Vertical airflow
(m)
2.1
Ion Deodorization Filter
(24/30)
(24/30)
Organic coating fin used
heat exchanger
1
0
Apple-catechin Filter
0
3
6
9
12(m)
(˚C)
46
Outside air conditions: 2°C 60%
Operation contents: Heating
Set temperature (Max set temp) 30°C,
Air flow Hi
Vertical flap: Downward
Horizontal flap: Center
o
Power diffuser (full open)
33
32
31
30
Pre Filter
29
Antibacterial deodorizing pre-filter with special ceramic powder
“Horizontal airflow” does not blow cool air
directly at the occupants in the room
Long-life* Ion
Deodorization Filter
Horizontal airflow
(m)
2.1
(24/30)
(24/30)
1
The filter deodorizes by powerfully decomposing absorbed
odors using the oxidizing and reducing effects of ions generated
by the ultra-fine-particle ceramic.
(*The filter can be used for approx. 3 years if it is washed under water to restore
its surface action when it is dirty.)
0
Power diffuser
0
3
6
Outside air conditions: 35°C 40%
Operation contents: Cooling
Set temperature (Min set temp) 18°C, Air flow Hi
Vertical flap: Upward
Horizontal flap: Center
9
15
16
Using different filters at both sides
12(m)
(˚C)
17
Easy maintenance
Simplification of drain pan cleaning improves maintenance-ability.
18
Apple-catechin Filter
Fine dust, invisible mold spores, and harmful microorganisms
are absorbed onto the filter by static electricity, and further
growth is inhibited and deactivated by the polyphenol ingredient
extracted from apples.
Specifications
AS*A18LACH
Model No.
Power source
Cooling
Capacity
Heating
Input power
kW
W
High
Air flow rate
Sound pressure level
Med
m3/h
AS*A30LACH
5.6
7.1
8.0
6.3
8.0
9.0
35
64
91
840
1,100
1,240
770
910
980
Low
690
730
770
High
41
48
52
39
43
45
35
35
35
Med
dB(A)
Low
mm
Dimensions (H x W x D)
kg
Weight
Liquid (Flare)
Connection
pipe diameter
AS*A24LACH
1Ø, 230V ~, 50Hz
V/ø/Hz
Gas (Frare)
320 x 998 x 228
15
ø9.52
mm
Drain
AS* : ASY(FUJITSU), ASH(GENERAL)
Note : Specifications are based on the following conditions.
ø15.88
ø12 (I.D.) ; ø16 (O.D.)
Cooling : Indoor temperature of 27˚CDB / 19˚CWB, and outdoor temperature of 35˚CDB / 24˚CWB.
Heating : Indoor temperature of 20˚CDB / (15˚CWB), and outdoor temperature of 7˚CDB / 6˚CWB.
Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m.
Voltage : 230 [V].
25
CONTROLLER
Control Systems
System diagram
The V-II system supports every users needs by offering a variety of Control systems,
including individual control, central control and building management control options.
Building
Management
Air Conditioning
Central Control
System Controller (Software)
UTY-APGX
Air Conditioning
Individual Control
Wired Remote Controller
UTY-RNK*
System
Outdoor unit
USB
Adaptor *2
Indoor unit
(Field supplied)
Internet or Public
Telephone Line
Simple Remote Controller
UTY-RSK*
Remote/Monitoring side
Touch Panel Controller
UTY-DTG*
Signal Amplifier
UTY-VSGX
Simple Remote Controller
UTY-RHK*
Without
master control
Central Remote Controller
UTY-DCG*
IR Receiver Unit
UTB-YWC
General-purpose
Building Control Computer
Wireless Remote Controller
UTY-LNH*
Group Remote Controller
UTY-CGG*
Network
Convertor
Connectable to
various sized BMS/BAS*1
IR Receiver Kit
UTY-LRH*B1
UTY-VGGX
BACnet ® Gateway (Software)
UTY-ABGX
USB
Adaptor *2
(Field supplied)
or
Network Convertor
(BMS / LONWORKS® )
UTY-VLGX
External
Switch Controller
UTY-TEKX
Card-key
For single split
(Field supplied)
Web Monitoring
Tool (Software)
UTY-AMGX
Service Tool (Software)
UTY-ASGX
USB
Adaptor*2
Internet or
Public Telephone Line
(VRF system side)
Network
Convertor
UTY-VGGX
(Field supplied)
USB
Adaptor*2
(Field supplied)
* : Y(FUJITSU), G(GENERAL)
(Monitoring side)
*1. BMS/BAS: Building Management System / Building Automation System
*2. USB Adaptor is U10 USB Network Interface of Echelon® Corporation.
The devices above cannot be connected to the S series.
(Except System Controller & BACnet® Gateway)
26
Transmission line (VRF Network)
LONWORKS ® Network
Remote controller line
Ethernet
USB cable
Signal line(Single split system)
Group Remote Controller line
Comparison table of Controllers
Item
Model name
Max. controllable remote controller groups
Wired Remote Simple Remote Simple Remote*1 Wireless Remote Group Remote Central Remote
Controller
Controller
Controller
Controller
Controller
Controller
Touch Panel System Controller
Software
Controller
UTY-RHK*
UTY-RSK*
UTY-RHK*
UTY-LNH*
UTY-CGG*
UTY-DCG*
UTY-DTG*
UTY-APGX
1
1
1
1
8
100
400
1600
*2
*2
*2
*2
*2
Max. controllable indoor units
9
9
9
9
18
100
400
1600
Max. controllable groups
-
-
-
-
-
16
400
1600
-
Air conditioning control function
On / Off
-
Operation mode setting
Fan speed setting
Room temp. setting
Room temp. set point limitation
-
Display
-
-
-
-
-
-
-
-
-
Right/left air direction flap setting
-
-
-
-
Group setting
-
-
-
-
-
-
RC prohibition
-
-
-
-
-
-
Anti freeze setting
-
-
-
-
-
-
-
-
-
-
Failure
-
Defrosting
-
Current time
-
-
Day of week
-
-
-
-
-
R.C. prohibition
Cooling/heating priority
-
Address display
-
Schedule timer
Timer
-
Up/down air direction flap setting
Economy mode setting
-
-
-
Week
-
-
-
On/off per day
4
-
-
-
4
20
20
72
On/off per week
28
-
-
-
28
140
140
504
Period
Week
Week
Year
Year
-
-
-
-
-
-
Sleep timer
-
-
-
-
-
-
-
Program timer
-
-
-
-
-
-
-
10
10
On/off timer
-
-
-
-
2
Min. unit of timer setting (Minutes)
30
-
-
5
10
10
Status monitoring system
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Day off
Electricity charge calculation
Control
-
Test operation
Error history
-
*3
*3
Emergency stop
-
-
-
-
-
-
Control via internet
-
-
-
-
-
-
-
E-mail notification for malfunction
-
-
-
-
-
-
-
-
K*:KY(FUJITSU), KYT(FUJITSU), KG(GENERAL), H*: HY(FUJITSU), HG(GENERAL), G*: GY(FUJITSU), GG(GENERAL)
*1 "Operation mode" setting is not available for this model.
*2 In the case of connection constitution for only J-II.
*3 This function is available only through external input. control.
27
CONTROLLER
Wired Remote Controller
Max. controllable
9
UTY-RNK*
indoor units
The room temperature can be controlled by detecting
the temperature accurately from the built-in sensor
•Simple operation with Built-in Weekly / Daily Timer.
•Control up to 9 indoor units.
•Up to 2 wired remote controllers can be connected to a single indoor unit.
Accurate and comfortable
Built-in timers
Indoor temperature can be detected accurately by the inclusion of a
thermo sensor in the body of the wired controller. This new wired
remote controller and the optional remote sensor allows flexibility in
sensor location, suitable for all requirements.
Weekly timer: Possible to set ON/OFF time to operate twice each
day of the week.
Setback timer: Possible to set temperature for two times spans
and for each day of the week.
At "Weekly timer" + "Set back timer" setup
Example of changing sensor
Indoor unit
Remote Sensor
in the bedroom
Diagnosis check function
Day
Wired Remote Controller
in the living room
Two methods are available for determining the cause of failure in
the event of a malfunction occurs:
Night
Wired remote
controller
Remote
sensor
The detecting point can be easily changed
Simple installation
Displayed temperature is set temperature.
Components are compatible with standard switch boxes.
Flat back surface allows to be installed wherever it is needed.
Simple Remote Controller
Max. controllable
9
UTY-RSK*
indoor units
UTY-RHK* (Without ability to change operation mode)
Compact remote controller provides access to basic functions
UTY-RSK*
•Up to 9 indoor units can be controlled with one remote controller.
•Suitable for hotels or offices as it is easily operated with no complex functions.
User-friendly operation
UTY-RHK*
Without ability to
change operation mode
Functions
•A large On / Off button is provided in the centre of
the remote controller for easy operation.
•Background light enables easy operation in a
darkened room.
•Following an error display, diagnostics can be
carried out on the controller.
UTY-RSK*
Model
UTY-RHK*
On / Off
Fan control
Operation mode
*1
Room temp. setting
*1: "Operation mode" setting is not available. It is recommend to use together with other
type controller.
Specifications
Model No.
Power Source
Dimensions (H x W x D) (mm)
Weight (g)
DC12V is supplied by the indoor unit.
K*: KY(FUJITSU), KYT(FUJITSU), KG(GENERAL)
28
UTY-RNK*
UTY-RSK*
DC 12V
DC 12V
UTY-RHK*
DC 12V
120 x 120 x 18
120 x 75 x 14
120 x 75 x 14
160
90 (100 : UTY-RSKYT)
90 (100 : UTY-RHKYT)
Wireless Remote Controller
Max. controllable
9
UTY-LNH*
indoor units
Selectable
Simple and sophisticated operations
with a choice of 4 daily timers
4
daily timers
•A single controller controls up to 9 indoor units.
UTY-LNH*
Built-in timers
System addressing
Select from 4 different timer programs:
On / Off / Program / Sleep
Program timer: The program timer operates the ON and OFF timer
once within a 24 hour period.
Sleep timer: The sleep timer function automatically corrects the set
temperature according to the time setting to prevent excessive
cooling or heating during sleep hours.
During installation work, system addressing can be performed using
the Wireless Remote Controller, thus eliminating manual switch
setting.
Transmission line
Indoor unit
Wireless
Remote Controller
Outdoor unit
Easy operation setting
Code selector switch
prevents indoor unit
mix-up. (Up to 4
codes can be set.)
Wide and precise
IR Receiver Unit
UTB-*WC
Duct type indoor unit
Necessary to control for all duct type by
Wireless Remote Controller
IR Receiver Unit
*WC : YWC, TWC
Wireless
Remote Controller
IR Receiver Kit
UTY-LRH*B1
Cassette type indoor unit can be controlled
with Wireless Remote Controller
Wireless
Remote Controller
IR Receiver Kit
Specifications
Model No.
Battery or Power source
Dimensions (H x W x D) (mm)
Weight (g)
UTY-LNH*
UTB-*WC
1.5V (R03 / LR03 / AAA) x 2
DC 12V
UTY-LRH*B1
DC 12V
158 x 56 x 20
122 x 60 x 26.5
213.8 x 213.8x 25.7
70
150
140
DC12V is supplied by the indoor unit.
H*: HY(FUJITSU), HG(GENERAL)
29
CONTROLLER
Group Remote Controller
Max. controllable
UTY-CGG*
group R.C. in a VRF
network system
64
Max. controllable
8
Group control of indoor units with simple operation
remote
controller groups
•Up to 8 remote controller groups can be controlled by one Group
Remote Controller.
•Up to 64 Group Remote Controllers can be connected in one VRF
network system.
Control up to 8 remote controller groups
•Single Group Remote Controller controls and monitors up to 8 remote controller groups.
Hotel floor
Network
Convertor
Guest room
Group Remote
Controller
1
Hotel
2
Simple Remote
Controller
Office floor
Office & Lounge
Office room
Meeting room
Office room
Wireless
Remote
Controller
Restaurant
Wired Remote Controller
Wireless
Remote
Controller
Wired
Remote
Controller
Restaurant
Wired Remote
Controller
Group Remote Controller 1 :
To control office floor and hotel floor (8 remote controller groups).
Group Remote Controller 2 :
To control hotel floor (5 remote controller groups).
Lobby
•Network Convertor is required to connect Group Remote Controllers to a
VRF network system.
(Network Convertor allows up to 4 Group Remote Controllers)
Network Convertor
UTY-VGGX
High performance and compact size
Built-in weekly timers
ON / OFF, Operating mode, Room temperature and Fan speed
setting can be controlled / monitored centrally or individually.
The weekly timer is provided as a standard function.
1. The timer can be set up for up to 4 times per day. (On / Off,
operating mode, set temperature)
2. Allows separate settings for each day of the week.
Central
control
ON/OFF
control
Weekly
timer
Specifications
Model No.
Power Source
Dimensions (H x W x D) (mm)
Weight (g)
DC12V is supplied by a network converter.
G*: GY(FUJITSU), GG(GENERAL)
30
Lobby
UTY-CGG*
DC 12V
120 x 120 x 18
200
Central Remote Controller
Max. controllable
100
UTY-DCG*
Indoor units
Max. controllable
Central control of small- and medium-sized buildings and tenants.
16
groups
• Individual control and monitor of 100 indoor units
• 5 inch TFT color screen
• User friendly view and easy operation
• Automatic display switching for the number of connected units
• Operation guidance display
• Automatic switching of function menu
• Corresponds to 7 different languages like English, Chinese, French, German, Spanish, Russian, Polish.
System overview
• It allows multiple indoor units grouping (Max.16 groups controlled)
• Interlock with external device
Group :
Hallway
Group : 3F
Group : Division A
Group : Division B
Group : Division C
Group : Tenant B
Group : Tenant C
Group : 2F
Group : Tenant A
Emergency stop function
• External input / output contact
• Detachable power supply unit
Functions
Diverse control of indoor units
• Individual control
• Remote controller prohibition
(All, On/Off,Mode, Temp.,Timer,Filter)
• Room temperature set point upper
and lower limitation
Weekly timer
Set temp.
Weekday
Automatic clock adjustment
28°C
26°C
Weekend
Holiday
28°C
26°C
26°C
26°C
28°C
28°C
8:00
12:00 13:00
18:00
21:00
Time
Setting pattern 1
Easy Installation
Setting pattern 2
Ceiling
SW BOX
• The control panel and power supply unit can be installed
separately.
• For flexibility in installation, the Control panel can be built
into the wall or fix on the wall.
Power
supply unit
Power supply
unit
Control
panel
Control
panel
Wall
Wall
Control panel + Power supply unit
Specifications
UTY-DCG*
Model No.
Power Source
Dimensions (H x W x D) (mm)
Weight (g)
Control Panel
Power Supply Unit
DC 5 V
100-240V, 50-60Hz, Single phase
120 x 162 x 26
99 x 135 x 40
308
355
PACKING LIST
Packing List
Control Panel / Power Supply Unit / Connecting cable, etc.
G*: GY(FUJITSU), GG(GENERAL)
31
CONTROLLER
Touch Panel Controller
Max. controllable
400
UTY-DTG*
indoor units
•Large-sized 7.5-inch TFT color
•LCD Easy finger touch operation
•Stylish shape and design to suit all application
•No additional component is required for installation
•Up to 400 indoor units can be controlled
•Selectable 2 display types (Icon / List) in monitoring mode
•Corresponds to 7 different languages, English, Chinese, French, German,
Spanish, Russian, Polish.
Real size screen image
Easy operation
Versatility
• Large and wide-angled LCD is easily viewable even at a distance
• Easy-to-understand icon-driven Graphical User Interface (GUI)
• Wide range of simple-to-understand icons
CSV format data edited by PC can be imported to
Touch Panel Controller.
Data transfer available
by USB
• Operation can be selected using your finger or the dedicated
touch pen by pressing the appropriate on-screen icon
• Up-to-date status display
• Background color identifies current control operation Blue for
monitoring, green for operational control
• Flat touch screen is easily cleaned
• Non-glare coating on touch panel controller minimizes fingerprint
marking
32
System overview
Up to 400 indoor units can be controlled
Group A
Group B
It allows multiple indoor unit grouping
Emergency stop control
Air conditioner can be turned
off through the external input control
Emergency stop function
Functions
• Up to 400 indoor units can be controlled
• It allows multiple indoor units grouping
• Schedule timer function is standard (20 patterns per day)
• Emergency stop function(through the external input control)
• Temperature upper and lower limit setting
• The clock of each indoor unit correct setting
Individual control
Flexible grouping
Schedule control
Indoor units operation monitoring
Automatic clock adjustment
The time setting of each
controller can be set in
batch automatically.
Easy installation & maintenance
Switch box
Touch Panel Controller is easily mounted to the wall. Flat back
surface allows to be installed wherever it is needed.
Mounted plate
• Correctable mechanism for tilting (horizontal)
after the installation of the body
No additional component is required for installation
• There is no need for the installation space of power supply adaptor and
transmission adaptor etc.
Easy-to-remove front cover
Specifications
Model No.
Power Source
Dimensions (H x W x D) (mm)
Weight (g)
Interface
UTY-DTG*
100-240V 50/60Hz
260 x 246 x 54
2,150
USB 2.0
G*: GY(FUJITSU), GG(GENERAL)
33
CONTROLLER
System Controller
Software
Max. controllable
4
UTY-APGX
VRF network systems
Max. controllable
System Controller realizes the advanced integrated monitoring
& control of VRF network system from small scale buildings to
large scale buildings.
400
outdoor units
Max. controllable
1,600
• Up to a maximum of 4 VRF network systems, 1600 indoor units, and
400 outdoor units can be controlled.
indoor units
• Supports VRF S series, V series, V-ll series and J-II series.
• In addition to air conditioning precision control function, central remote control, electricity charge calculation, schedule
management, and energy saving functions are strengthened and building manager and owner needs are met.
• Corresponds to 7 different languages (English, Chinese,French, German, Spanish, Russian, Polish)
Remote centralized control
System Controller may be used on site or remotely over various
networks for remote central control. System Controller requires
2 softwares working together. VRF Controller runs on site and
communicate with VRF system. VRF Explorer runs remotely and
provides user interface and communicate with the VRF Controller.
VRF Controller and VRF Explorer program may run in a single PC
or in different PCs separated by network. By using VRF Explorer
software, one PC can perform central control of 10 VRF system
sites with max. 20 buildings per site.
Remote central control
1 VRF Explorer can control or monitor up to 10 sites.
VRF Explorer
Building management company,
management center, etc.
VRF Controller
A maximum of
10 locations, such as
offices or factories
VRF Controller
On site central control
Internet
or
Telephone Line
or
LAN
Max. 4 VRF network
systems per site
Internet
or
Telephone Line
or
LAN
1 VRF Controller can be monitored from any number
of VRF Explorers (Up to 5 connections simultaneously).
VRF Explorer
Building Management
VRF Explorer Company A (In charge of
Central Monitoring Screen
for all Properties
the day shift)
VRF Explorer
VRF Explorer
Building
Management Company B
(In charge of the night shift)
Internet
or
Telephone Line
or
LAN
VRF Explorer
Office Management Center
VRF Controller
VRF Explorer
Security Company
Headquarters Management Center
Special Property Detailed Monitoring Screen
User friendly view and operation
Monitoring located site
Main operation monitoring screen
Monitor mode (Site)
Monitor mode (Building)
34
Operation monitoring of each site
Management functions
Monitor mode (Floor)
Schedule setting
Monitor mode (List)
Functions
Energy saving management
Option
UTY-PEGX:software
Peak cut operation
Outdoor unit capacity save
Indoor unit rotation operation
Controls overall operation while maintaining
comfort according to the overall power
consumption target value.
Sets an upper limit of outdoor unit capacity
and performs capacity save operation at peak
times.
Reduces annual power consumption by
operating indoor units in rotation.
Outdoor unit
stop range
Forced thermostat
off range
Target power
consumption
Indoor unit rotation screen
Power consumption
Outdoor unit capacity control screen
Ideal control line (Use of
Shows change in power
average power consumption) consumption by time
Outdoor unit capacity
upper limit
Time
Electricity charge apportionment
Others
Apportions the power used by indoor and outdoor units and
automatically calculates the electricity charge for each tenant.
When you want to calculate the power used during a certain period
in hotels, etc., computation linked with an electric meter is also
possible. (Option)
•Batched stop
•Divers control of indoor units
•Oprating & control record
•Schedule control
•Error display & E-mail nitification
•Prohibition setting
Billing management for users for a set period
of time, such as for hotels
System Controller
CT
Option
Signal transmission line
1Ø, 2wire
230V, 50Hz
DPM
Room 301
Room 302
Room 303
Room 201
Room 202
Room 203
Room 101
Room 102
Room 103
Outdoor
unit
1Ø, 2wire
230V, 50Hz
Specifications
UTY-APGX
Model No.
Personal Computer
AT compatible machine that runs Microsoft® Windows®
Operating System
Microsoft® Windows® XP Professional (Service Pack 3 or later / English version),
Microsoft® Windows Vista® Home Premium, Business (Service Pack 2 or later / Corresponds to 7 different languages.*),
Microsoft® Windows® 7 Professional (64-bit is not supported. / Corresponds to 7 different languages.*)
*English, Chinese, French, German, Spanish, Russian, Polish
CPU
Intel® Pentium® / Celeron 2 GHz (VRF Controller), 1 GHz (VRF Explorer) or higher
HDD
40 GB or more of free space (5 GB for VRF Explorer PC)
Memory
2 GB or more (VRF Controller), 1 GB or more (VRF Explorer)
Interface
USB port is required for each of the followings for Server PC ;
• Wibu Key (Software protection key) • Echelon® U10 USB Network Interface (Required for each VRF Network)
Ethernet port is required for remote connection using internet.
Accelerator
Requires the internal graphics accelerator be compatible with Microsoft® DirectX® 9.0
Other Software Required
Adobe® Reader® 9.0 or later
PACKING LIST
Wibe Key
Includes the software for System Controller. Both VRF Controller and VRF Explorer software is included.
CD-ROM
Software protection key to be inserted in a USB slot running System Controller.
System Controller may only run on a PC with Wibu Key. Remote VRF Explorer software does not require Wibu Key.
Personal computer must be field supplied. U10 USB Network Interface must be field supplied. Contact Echelon® Corporation or its local sales representative for detail.
Product Name : U10 USB Network Interface - TP/FT-10 Channel Model Number: 75010R
35
CONVERTOR & ADAPTOR
Network Convertor
UTY-VGGX
•This network convertor is to be used for connecting single split system or
group remote controller with the VRF network system.
•Please select the function by switching the dip switch during the installation.
Installation example
•Split type systems can be controlled from a central remote controller or PC controller through connection to the VRF's network convertor.
•Standard remote controller and central remote controller provide On / Off control, master control, temperature and fan control, etc.
•A single network convertor can be used to connect and control up to 16 single units.
Network Convertor
Group of Single Split
USB
adaptor
VRF network
system
Single Split
System Controller
Please consult your distributor for connectable split type air conditioner. Up to 100 network convertors may be
connected in a single VRF network system. A single network convertor is considered as a single refrigerant
system, irrespective of the number of connected single models.
Big Multi
Used for connecting Group Remote Controller
4 group remort controllers can be connected to a single Network convertor.
Network Convertor
Group
Remote Controller
* 2 refrigerant circuits can be covered by a single network convertor.
Up to a total of 16 network convertors, Central remote controller
and Touch panel controllercan be connected in one VRF network
system.
VRF network
system
Specifications
Model No.
Power Source
Power Consumption (W)
Dimensions (H X W X D) (mm)
Weight (g)
36
UTY-VGGX
50-60Hz 220-240V
8.5
67 x 288 x 211
1,500
Model No.
Power Source
Power Consumption (W)
Dimensions (H X W X D) (mm)
Weight (g)
UTY-VLGX
220-240V 50/60Hz
4.5
67 x 288 x 211
1,500
Network Convertor for LONWORKS ®
Max. controllable
Max. controllable
4
128
Units to BMS
UTY-VLGX
indoor units
•For connection between VRF network system and a LONWORKS ® open network for management of small
to medium-sized BMS and VRF network system.
•The unit permits central monitoring and control of a VRF network system from a BMS through a LONWORKS ® interface.
•Up to 128 Indoor units can be connected to one Network Convertor for LONWORKS ®
Installation example
General-purpose building control computer
(LONWORKS® device)
Max. 4
Network
Convertor
Transmission specifications (BMS side)
Max. 100
Max. 128 indoor units
outdoor units
Transmission speed
78kbps
Transceiver
FT-X1 (Echelon® Corporation)
Transmission way form
Lighting facilities
Network
Convertor
Security system
Free topology
None
(It attaches at the terminal of a network.)
Terminal resistor
VRF network system 1
Max. 100
Max. 128 indoor units
outdoor units
Automatic fire
alarm interface
Ventilation system
LONWORKS® Network
BACnet ® Gateway
VRF network system 2
Software
UTY-ABGX
Max. controllable
Max. controllable
4
400
VRF network systems
Max. controllable
outdoor units
1,600
indoor units
•The VRF network system can be incorporated into a Building Management System.
•Enables central control of up to 1,600 indoor units through BACnet®, a global standard for open networks.
•Conforms to ANSI / ASHRAE Standards® 135-2004 BACnet® Application Specific Controller (B-ASC)
BACnet® / IP over Ethernet.
•Connects up to 4 VRF network systems (1,600 indoor units / 400 outdoor units) per gateway.
•Supports VRF S/V series, V-II series and J-II series
Installation example
BACnet
VRF network system 1
CD-ROM
(Software)
Software
Protection Key
®
The BACnet Gateway version 2.0
is eligible to display BTL Mark.
Founded by BACnet International,
BTL (BACnet Testing
Laboratories) is an indication of
worth trusting for its quality after
passing the strict tests.
BACnet ® Operator
Workstation (B-OWS)
USB adaptor*1 (Field supplied)
Indoor unit
Outdoor unit
Lighting facilities
VRF network system 2
Security system
USB adaptor (Field supplied)
®
BACnet Gateway
Indoor unit
Outdoor unit
Max. 4
VRF network systems
(UTY-ABGX)
USB adaptor (Field supplied)
USB adaptor (Field supplied)
CD-ROM
Software
(Software) Protection Key
Automatic fire alarm interface
Ventilation system
= BACnet® Gateway for each system.
= USB cable
= Transmission line (VRF Network)
= Ethernet
*1: USB adaptor is U10 USB Network
Interface of Echelon® Corporation.
Specifications
UTY-ABGX
Model No.
Personal Computer
AT compatible machine that runs Microsoft® Windows®
Operating System
Microsoft® Windows® XP Professional (Service Pack 3 or later / Corresponds to 7 different languages.*)
Microsoft® Windows Vista® Home Premium, Business (Service Pack 2 or later / Corresponds to 7 different languages.*)
Microsoft® Windows® 7 Home Premium, Professional (Corresponds to 7 different languages.*)
*English, Chinese, French, German, Spanish, Russian, Polish
•64-bit version of Windows® are not supported.
CPU
Intel® Pentium® / Celeron®, AMD Athlon / Duron processor 2 GHz or higher
HDD
40 GB or more of free space
Memory
2 GB or more
Interface
USB port (x 2-5) is required
Ethernet port is required
Other Software Required
Adobe® Reader® 9.0 or later
PACKING LIST
Packing List
CD-ROM / Wibu Key
Personal computer must be field supplied. U10 USB Network Interface must be field supplied. Contact Echelon® Corporation or its local sales representative for detail.
Product Name : U10 USB Network Interface - TP/FT-10 Channel Model Number : 75010R
37
CONVERTOR & ADAPTOR
Signal Amplifier
UTY-VSGX
•Transmission Line length can be extended up to 3,600m for with
multiple Signal Amplifiers.
•Up to 8 signal amplifiers can be installed in a VRF network system.
•A signal amplifier is required,
(1) When the total wiring length of the transnission line exceeds 500m.
(2) When the total number of units on the transnission line exceeds 64.
Installation example
B
C
A
E
Signal Amplifier
External Switch Controller
UTY-TEKX
Air conditioner switching can be controlled by connecting other sensor switches
•In combination with a field supply Card-Key Switch or other sensor, the External Switch Controller
allows control of the ON / OFF, Room temperature, Fan speed and Master control functions. This
makes this product suitable for installations such as hotel rooms.
•Card-key or other sensor switches are available as a field supplied parts.
Electrical wiring
Auto mode operation, which switches the cooling and the heating
automatically, is enabled by using the sensor switch and External
Switch Controller.
Note: All indoor units will operate in the same mode.
Room temp.
Installation example
T2
Indoor
Unit
Heating
Time
T1 = ON, T2 = OFF
Note 1.
Please choose a thermosensor
switch which can be set up
for T1 and T2.
SU MO TU WE TH FR SA
7
3 6 9 12 15 18 21
Sensor SW
(Field supplied)
To individual dry contact
Card-key
Cooling
T1
External Switch Controller (UTY-TEKX)
Note 2.
The remote controller's operation is
prior to the auto mode operation.
1
2
3
E
COM SW1 SW2
Remote
Controller
Line
External
input
Card-key
(Field
supplied)
External Switch Controller
Sensor SW
Indoor
Unit
1
2
3
E
COM SW1 SW2
Remote
Controller
Line
External
input
Sensor SW
(Field
supplied)
External Switch Controller
Specifications
Model No.
Power Source
Power Consumption (W)
Dimensions (H X W X D) (mm)
Weight (g)
38
UTY-VSGX
220-240V 50/60Hz
4.5
67 x 288 x 211
1,500
Model No.
Power Source
Dimensions (H X W X D) (mm)
Weight (g)
DC12V is supplied by the indoor unit.
UTY-TEKX
DC 12V
120 x 75 x 30
90
SERVICE & MONITORING
Service Tool
Software
Max. Monitor
and controll
Max. Monitor
and controll
indoor units
outdoor units
400
UTY-ASGX
100
Extensive monitoring and analysis functions for installation and maintenance
•Operation status can be checked and analyzed to detect even the smallest abnormalities
•Storage of data on system operation status on a PC allows access even from off site.
•Up to 400 indoor units (a single VRF network system) can be controlled and monitored for large scale buildings or hotels
•This software can be connected to any point of transmission line with USB adaptor (field supplied).
•Supports VRF S/V series, V-II series and J-II series.
Wiring connection
(Field supplied)
Functions
USB adaptor
(Field supplied)
•Equipment Detail (Diagram)
Transmission line
Refrigerant piping
•Equipment Detail (List)
•Operation History
•Error History
•Remote File Download
•System List
•Commissioning Tool
•Network Topology Analyzer
Indoor unit
Indoor unit
Web Monitoring Tool
•Remote setting
•System Time Setting
•Central Release
•Model Name Writer
•Error Memory Reader
•Time Guard Information
•Software Version acquire and display
Software
VRF network system
can be supported
4
1,600
UTY-AMGX
Product features
indoor units
•Troubleshooting is performed by monitoring each air conditioning unit remotely during periodical system checks.
can be supported
•Error notification can be automatically transmitted to several locations using the internet*1.
•Requires either a dedicated internet connection or public telephone line.
•Determination of an error occurrence can be made through error warnings and equipment status information obtained from a remote location.
•The monitoring data in a remote side can be optionally downloaded. And, this data can be displayed in offline mode of the service tool.
•Monitoring side computer is not required to install special software, requires only general web browser.
•Supports VRF S/V series , V-II series and J-II series.
*1: Use of internet mail system required.
Web Monitoring System
Support 4 VRF network systems
USB adaptors
Monitoring Side
Internet
or
Public
Telephone
Line
USB adaptor (max. 4
adaptors per PC) permit,
monitoring of up to 1,600
indoor units.
Suitable for large-scale
buildings or hotels.
VRF Network System Side
Outdoor unit
Transmission line
Web
Monitoring
Tool
USB adapter
(Field supplied)
Indoor unit
VRF Network
System 1
VRF Network
System 2
VRF Network
System 3
VRF Network
System 4
Max. 400
Indoor unit
Max. 400
Indoor unit
Max. 400
Indoor unit
Max. 400
Indoor unit
Specifications
Model No.
UTY-ASGX
Operating System
Microsoft® Windows® XP Professional (English version / Service pack 3 or later), Microsoft® Windows® Vista® Home Premium,
Business Edition (English version), Microsoft® Windows® 7 Professional (64-bit is not supported. / English version)
Intel® Pentium® / Celeron®, AMD AthlonTM / DuronTM 1 GHz or higher
CPU
10 GB or more of free space
HDD
Memory
UTY-AMGX
AT compatible machine that runs Microsoft® Windows®
Personal Computer
1 GB (Vista, 7), 512 MB (XP) or more
40 GB or more of free space
1 GB or more
USB port for U10 USB Network Interface and Software protection key.
Interface
USB port (for U10 USB Network Interface Max.4, Software protection key)
Following interface is required for remote connection:
Public Telephone LIne : Modem is required
Internet using LAN : Ethernet port is required
Software
Internet Explorer 6.0 or 7.0 or 8.0 / Adobe® Reader® 9.0 or later
Hardware
CD-ROM drive
PACKING LIST
Packing List
CD-ROM / Wibu Key
Personal computer must be field supplied. U10 USB Network Interface must be field supplied. Contact Echelon® Corporation or its local sales representative for detail.
Product Name : U10 USB Network Interface - TP/FT-10 Channel Model Number: 75010R
39
OTHERS
VRF System Design
1. Quick model selection and design tool "Design Simulator" for VRF
Fujitsu General offers software which quickly performs model
selection and creates material for model estimation in the VRF
initial design stage. "Design Simulator" has functions which
automatically select the proper model for the required capacity,
automatically draft piping diagrams and wiring diagrams, and also
automatically calculate the additional refrigerant charge amount,
automatically generates the reports necessary for estimation.
Operation is also easily performed by drag & drop and full-fledged
model design estimates can be quickly made.
Features
• Automatic model selection of indoor unit and outdoor unit
• Simple drag & drop operation
• Automatic generation of piping diagrams and wiring diagrams
• Automatic calculation of additional refrigerant charge amount
• Auto CAD Data (DXF), Revit Mep Data (RFA) export
• Automatic report generation (Word, Excel)
• Multi-language capability
Design Simulator
for
FUJITSU VRF
2. 2D (DXF), 3D (RFA) contents data
Two kinds of model data, DXF data and RFA data, necessary in
detailed design are offered.
These data can be procured from the Fujitsu General web
site and Design Simulator
RFA data
40
FGL Web site
Optional Parts
Controllers
Wired Remote Controller
Simple Remote Controller
Simple Remote Controller
UTY-RNK*
UTY-RSK*
UTY-RHK*
With operation mode
Without operation mode
Wireless Remote Controller
IR Receiver Unit
IR Receiver Kit
UTY-LNH*
UTB-YWC
UTB-TWC
UTY-LRH*B1
For All Duct type
For Cassette type
Group Remote Controller
Central Remote Controller
Touch Panel Controller
UTY-CGG*
UTY-DCG*
UTY-DTG*
System Controller
Software
UTY-APGX
K*:KY(FUJITSU), KYT(FUJITSU), KG(GENERAL), H*: HY(FUJITSU), HG(GENERAL), G*: GY(FUJITSU), GG(GENERAL)
Convertors / Adaptors
Network Convertor
Network Convertor
BACnet ® Gateway
UTY-VGGX
for LONWORKS®
UTY-VLGX
UTY-ABGX
CD-ROM
(Software)
Signal Amplifier
External Switch Controller
UTY-VSGX
UTY-TEKX
Software
Software
Protection Key
41
OTHERS
Optional Parts
Connection Tube
Separation Tube
Header
Header
UTR-BP090X
UTR-H0906L
UTR-H0908L
Gas Pipe
Gas Pipe
Liquid Pipe
Gas Pipe
Liquid Pipe
Liquid Pipe
Header
3-6 Branches
UTR-H0906L
3-8 Branches
UTR-H0908L
Model name
Others
Indoor unit type
Item
Round
Compact
Duct
Slim Duct
-
-
Flange
Square
Remote
Sensor Unit
Long-Life Filter
Auto Louver
Grille Kit
Drain
Pump Unit
Wide Panel
-
Duct
UTD-RF204
UTD-RF204
UTD-RS100
-
-
UTD-GXSA-W
UTD-GXSB-W
UTD-GXSC-W
UTD-SF045T
UTD-SF045T
UTD-RS100
UTD-RS100
UTD-RS100
UTD-LF25NA
UTD-LF25NA
UTD-LF60KA
-
-
UTZ-PX1NBA
UTZ-PX1NBA
-
Air Outlet
Shutter Plate
-
Panel Spacer
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
UTR-DPB24T
-
UTG-AGYA-W
UTG-AGYA-W
UTR-YDZC
UTR-YDZC
UTG-BGYA-W
UTG-BGYA-W
UTG-UFYC-W
UTG-UFGC-W
UTG-UGYA-W
UTG-UGGA-W
UTG-UGYA-W
UTG-UGGA-W
UTZ-KXGC
UTZ-KXGB
UTZ-KXGA
UTZ-VXAA
UTZ-VXGA
UTZ-VXGA
-
-
-
-
-
-
-
-
-
-
Fresh Air
Intake Kit
-
EV Kit
-
-
-
-
Insulation Kit for
High Humidity
-
-
-
-
-
-
Wall
Mounted
-
-
-
-
Compact Wall
Mounted
-
-
-
-
Ceiling
-
-
-
Floor /
Ceiling
-
UTR-YDZB
-
Cassette
-
-
Grill Kit
-
Slim
Cassette
UTD-RF204
-
UTZ-PX1BBA
High Static Compact
Duct
Cassette
-
-
UTD-RS100
-
Low Static
Duct
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
UTR-EV09XB
UTR-EV14XB
42
Flange (Round)
Flange (Square)
Remote Sensor Unit
UTD-RF204
UTD-SF045T
UTD-RS100
For Low Static Pressure Duct type /
Duct type / Ceiling type
For Low Static Pressure Duct type /
Duct type
For All Duct type
New amenity space can be
offered by installing
the Remote sensor.
Long-Life Filter
Long-Life Filter
Auto Louver Grille Kit
UTD-LF25NA
UTD-LF60KA
For Low Static Pressure Duct type /
Duct type
For High Static Pressure
Duct type
UTD-GXSA-W (for ARXD07/09/12/14LATH)
UTD-GXSB-W (for ARXD18LATH)
UTD-GXSC-W (for ARXD24LATH)
For Slim Duct type
Drain Pump Unit
Drain Pump Unit
Wide Panel
UTZ-PX1BBA
UTR-DPB24T
UTG-AGYA-W
For Compact Duct type
For Ceiling type
For Cassette type
UTZ-PX1NBA
Indoor unit
950
For Low Static Pressure Duct type /
Duct type
Panel 600
600
Air Outlet Shutter Plate
Air Outlet Shutter Plate
Panel Spacer
UTR-YDZB
UTR-YDZC
UTG-BGYA-W
For Compact Cassette type
For Cassette type
For Cassette type
Shuts the air outlet when only using as 3 blow out.
Shuts the air outlet when only using as 3 blow out.
(mm)
50mm
Panel spacer
Grille Kit
Grille Kit
Insulation Kit for High Humidity
UTG-UFYC-W
UTG-UFGC-W
UTG-UGYA-W
UTG-UGGA-W
UTZ-KXGA For Cassette type
UTZ-KXGB For Slim Cassette type
UTZ-KXGC For Compact Cassette type
Insulation Kit
For Compact Cassette type
For Cassette type
Fresh Air Intake Kit
Fresh Air Intake Kit
EV Kit
UTZ-VXAA
UTZ-VXGA
UTR-EV09XB (for AS*E07/09LACH)
UTR-EV14XB (for AS*E12/14LACH)
For Compact Cassette type
For Cassette type
For Compact Wall Mounted type
(EEV external type)
43
1116, Suenaga, Takatsu-ku, Kawasaki 213-8502, Japan
http://www.fujitsu-general.com/
ISO 9001
ISO 14001
Certified number : 01 100 89394 Certified number : 01 104 9245101
Fujitsu General (Thailand) Co., Ltd.
ISO 9001
Certified number : 01 100 79269
ISO 14001
Certified number : 272043
Fujitsu General (Shanghai) Co., Ltd.
ISO 9001
Certified number : 00608Q11061R2M
ISO 14001
Certified number : 00609E20454R2M
Fujitsu General Central Air-conditioner (Wuxi) Co., Ltd.
“
” is a worldwide trademark of FUJITSU GENERAL LIMITED and is a registered trademark in Japan, the U.S.A. and other countries or areas.
*Echelon ®, LONWORKS ®, and the Echelon logo are trademarks of Echelon Corporation registered in the United States and other countries.
*BACnet ® is a registered trademark of the American Society of Heating Refrigeration and Air Conditioning Engineers (ASHRAE).
The colors may be different from the actual colors because this catalog is printed matter.
Product specifications are subject to change without notice.
Distributed by :
Copyright© 2011 Fujitsu General Limited. All rights reserved.
6NNJ22-1201E