Download Miele T 8622C Operating instructions
Transcript
Cleaning and care Cleaning the condenser unit Detergent residue, hair and fine fluff from the dryer can get through the fluff filters and block the condenser unit. Dust from the room in which the dryer is installed can also get into the condenser unit and cause a blockage. Check the condenser unit at least twice a year. Always check it if the Clean out airways message appears. If the dryer is used frequently then check the condenser unit after approx. 100 drying cycles. Clean it if necessary. ^ Turn the lever on the inner cover downwards to the vertical position. ^ Tilt the cover forwards. Removing the condenser unit ^ Remove it by pulling it diagonally upwards. ^ Open the service panel. Hold the panel securely when doing this. ^ Turn the lever on the condenser unit upwards to the vertical position. ^ Now remove the panel by pulling it diagonally upwards and place it to one side. 29