Download Code Alarm CR3 Instruction manual

Transcript
1Error list
Error No.
L3300
L3310
L3320
L3330
L3340
L3350
L3360
L3361
L3370
L3380
L3390
L3400
L3500
L3600
L3700
L3710
Error cause and measures
Error message
User slot cannot be executed
Cause
A user slot cannot be executed.
Measures
Check whether the system slot is being operated.
Error message
Cannot execute XRUN (Runing)
Cause
XRUN is not possible as the designated slot is operating.
Measures
Stop the specification slot, and execute.
Error message
Cannnot execute XRUN (empty)
Cause
XRUN is not possible as the program has not been selected.
Measures
Specify program name to the argument or execute XLOAD.
Error message
Cannnot execute XSTP (empty)
Cause
XSTP is not possible as the program has not been selected.
Measures
correct the program, and execute.
Error message
Cannnot execute XRST (empty)
Cause
XRST is not possible as the program has not been selected.
Measures
Resetting is possible in the state of waiting only.
Error message
Cannnot execute XRST (Running)
Cause
XRST is not possible as the program is executing.
Measures
Stop execution, and do it.
Error message
Cannnot execute XLOAD (not PSA)
Cause
XLOAD cannot be executed when the program cannot be selected.
Measures
Execute XRST, and do it.
Error message
Can not load the program(SLT*)
Cause
A non-existing program was specified in the slot parameter (SLTn).
Measures
A non-existing program was specified in the slot parameter (SLTn).
Error message
Cannnot execute XCLR (empty)
Cause
XCLR is not possible as the program has not been selected.
Measures
XCLR can only be executed to enable program selection.
Error message
Cannnot execute XCLR (not PSA)
Cause
Program selection is not enabled.
Measures
Execute XCLR after resetting the program (canceling the abort status).
Error message
Cannot use arc pallet
Cause
Cannot use arc pallet.
Measures
Change to another method.
Error message
System error (PROC stack over)
Cause
System error. (Processor stack overflow. )
Measures
When it comes back, contact to the dealer
Error message
Ilegal format input (INPUT)
Cause
The type of the variable specified by INPUT and the type of the received data do not match.
Measures
Check the format.
Error message
Jump destination does not exist
Cause
No jump destination was found for the DEF ACT, ON COM and ON GOTO commands.
Measures
Check the jump destination.
Error message
Undefined variable
Cause
It was attempted to reference a variable that has not been initialized.
Measures
Define a variable, enter an initial value, and then use it.
Error message
Nesting over (CALLP)
Cause
Program CALL is used more than the limitation.
Measures
Reduce the call count of CALLP (nesting).
Error no. L3300
1-19