Download Code Alarm CR3 Instruction manual
Transcript
1Error list Error No. L3300 L3310 L3320 L3330 L3340 L3350 L3360 L3361 L3370 L3380 L3390 L3400 L3500 L3600 L3700 L3710 Error cause and measures Error message User slot cannot be executed Cause A user slot cannot be executed. Measures Check whether the system slot is being operated. Error message Cannot execute XRUN (Runing) Cause XRUN is not possible as the designated slot is operating. Measures Stop the specification slot, and execute. Error message Cannnot execute XRUN (empty) Cause XRUN is not possible as the program has not been selected. Measures Specify program name to the argument or execute XLOAD. Error message Cannnot execute XSTP (empty) Cause XSTP is not possible as the program has not been selected. Measures correct the program, and execute. Error message Cannnot execute XRST (empty) Cause XRST is not possible as the program has not been selected. Measures Resetting is possible in the state of waiting only. Error message Cannnot execute XRST (Running) Cause XRST is not possible as the program is executing. Measures Stop execution, and do it. Error message Cannnot execute XLOAD (not PSA) Cause XLOAD cannot be executed when the program cannot be selected. Measures Execute XRST, and do it. Error message Can not load the program(SLT*) Cause A non-existing program was specified in the slot parameter (SLTn). Measures A non-existing program was specified in the slot parameter (SLTn). Error message Cannnot execute XCLR (empty) Cause XCLR is not possible as the program has not been selected. Measures XCLR can only be executed to enable program selection. Error message Cannnot execute XCLR (not PSA) Cause Program selection is not enabled. Measures Execute XCLR after resetting the program (canceling the abort status). Error message Cannot use arc pallet Cause Cannot use arc pallet. Measures Change to another method. Error message System error (PROC stack over) Cause System error. (Processor stack overflow. ) Measures When it comes back, contact to the dealer Error message Ilegal format input (INPUT) Cause The type of the variable specified by INPUT and the type of the received data do not match. Measures Check the format. Error message Jump destination does not exist Cause No jump destination was found for the DEF ACT, ON COM and ON GOTO commands. Measures Check the jump destination. Error message Undefined variable Cause It was attempted to reference a variable that has not been initialized. Measures Define a variable, enter an initial value, and then use it. Error message Nesting over (CALLP) Cause Program CALL is used more than the limitation. Measures Reduce the call count of CALLP (nesting). Error no. L3300 1-19