Download Bosch 520-PN-L Specifications
Transcript
Appliance details | 7 • CAUTION: ▶ Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. Freeze prevention kit (7709003775)1) Safety devices • Flame failure device (ionization flame rod sensor) • Pressure relief valve (Available as accessory) • Over heat prevention (temperature limiter) Capacity Maximum output BTU/hr 91 525 Btu/hr Maximum input BTU/hr 117 000 Btu/hr % > 78% BTU/hr 30 735 Btu/hr inches ½ ” NPT Thermal efficiency (Efficiency in %) Minimum Input Gas Requirement Gas connection Inlet gas pressure under maximum operation1) Propane water column 10.5” - 14” Natural Gas water column 5.7” - 14” Hot water connection inches ½ ” NPT Cold water connection inches ½ ” NPT GPM (l/ min) PSI (bar) 0.5 (1.9) Water Minimum water flow Minimum recommended water pressure 30 PSI (2.07 bar) Water valve material Fibreglass reinforced polyamide (PA) Connections: Bottom of heater Dimensions Fig. 1 3 Appliance details 3.1 520 PN specifications (Technical data) Depth inches (mm) 8.66” (220 mm) Width inches (mm) 16.73” (425 mm) Table 2 Approved in US/Canada Capacity 520 PN: 4.3 GPM Accessories (Bosch part #) • Pressure relief valve (FWL-2) 520 PN 1) The freeze prevention kit is designed to provide protection for the water heater down to approximately 5°F for short term conditions only. It will not protect the appliance in areas where the temperature is routinely expected to be below freezing. - The freeze prevention kit will not protect plumbing outside the appliance from freezing. Precautions should be taken. 6 720 644 947 (2014/11)