59
7.2
EFKA AB220A5111
Operator Level
The preset values of the following list of parameters refer to the setting of parameter 290 = 0.
Parameter
Designation
000
c2 - Number of stitches of start backtack forward
- Number of stitches of start stitch condensing
without stitch regulator
- Number of stitches of end counting “chain
Unit
stitches
max
254
min
0
Preset
2
*)
Ind.
A
001
c1 - Number of stitches of start backtack backward stitches
- Number of stitches of start stitch condensing
with stitch regulator
- Number of stitches of start counting “chain
254
0
4
*)
A
002
c3 - Number of stitches of end backtack backward stitches
- Number of stitches of end stitch condensing
with stitch regulator
- Number of stitches of tape cutter at the start
of the seam
c4 - Number of stitches of end backtack forward
stitches
- Number of stitches of end stitch condensing
without stitch regulator
- Number of stitches of tape cutter at the seam
end
LS Light barrier compensating stitches
stitches
LSF Number of stitches of the light barrier filter for
stitches
knitted fabrics
LSn Number of light barrier seams
Stc Number of stitches for the seam with stitch
stitches
counting
-F- A parameter from the technician level is assigned to
the 9 key on the V820 control panel
1 = Softstart On/Off
2 = Ornamental backtack On/Off
3 = Sewing start blocked with light barrier uncovered
On/Off
4 = Unlocking the chain On/Off
5 = Signals A1 and/or A2 On/Off with slide-in strips
1...4 (lefthand arrow = A1, righthand arrow = A2)
LS Light barrier On/Off
FA Thread trimmer On/Off
FW Thread wiper On/Off
StS Stitch counting On/Off
UoS 0 =
Sequence “overlock mode with stop”
1=
Sequence “overlock mode without automatic
stop. When the command “run” is given, the
drive runs at the preselected speed. With
pedal in pos. 0 or light barrier covered, the
program switches to the next start of a seam
without issuing signals M1/M2.
2=
As with setting “1”. But with pedal in pos. 0
signals M1/M2 will be issued, and the program
switches to the next start of a seam.
3=
As with setting “1”. But with pedal in pos. -2
signals M1/M2 will be issued, and the program
switches to the next start of a seam. Intermediate stop and sewing foot lift with pedal
in pos. –1 are possible.
254
0
2
*)
A
254
0
2
*)
A
254
254
0
0
7
1
*)
A
A
15
254
1
0
1
20
*)
A
A
5
1
1
*)
A
1
1
1
1
3
0
0
0
0
0
0
1
1
0
0
*)
*)
*)
A
A
A
A
A
003
004
005
006
007
008
009
013
014
015
018
*)
Depending on the selected mode. See table at the beginning of the List of Parameters!