Download Carrier Pro-Dialog CONTROL 4 Specifications
Transcript
18 - STANDARD MAINTENANCE • Air conditioning equipment must be maintained by professional technicians, whilst routine checks can be carried out locally by specialised technicians. • Simple preventive maintenance will allow you to get the best performance from your HVAC unit: • improved cooling performance • reduced power consumption • prevention of accidental component failure • prevention of major time-consuming and costly interventions • protection of the environment There are five maintenance levels for HVAC units, as defined by the AFNOR X60-010 standard. 18.1 - Level 1 maintenance See note below. Simple procedure can be carried out by the user: • Visual inspection for oil traces (sign of a refrigerant leak), • Air heat exchanger (condenser) cleaning - see chapter ‘Condenser coil - level 1’, • Check for removed protection devices, and badly closed doors/covers, • Check the unit alarm report when the unit does not work (see report in the 30RB Pro-Dialog Plus control manual). General visual inspection for any signs of deterioration. 18.2 - Level 2 maintenance See note below. This level requires specific know-how in the electrical, hydronic and mechanical fields. It is possible that these skills are available locally: existence of a maintenance service, industrial site, specialised subcontractor. In these cases, the following maintenance operations are recommended. Carry out all level 1 operations, then: • At least once a year tighten the power circuit electrical connections (see table with tightening torques opposite), • Check and retighten all control/command connections, if required (see table with tightening torques opposite), • Remove the dust and clean the interior of the control boxes, if required, • Check the presence and the condition of the electrical protection devices, • Check the correct operation of all heaters, • Replace the fuses every 3 years or every 15000 hours (age-hardening), • Check the water connections, • Purge the water circuit (see chapter ‘Water flow control procedure’), • Clean the water filter (see chapter ‘Water flow control procedure’), • Fully clean the condensers with a low-pressure jet and a bio-degradable cleaner (counter-current cleaning see chapter ‘Condenser coil - level 2), • Replace the stuffing box packing of the pump after 10000 hours of operation, 50 Check the unit operating parameters and compare them with previous values, Keep and maintain a maintenance sheet, attached to each HVAC unit. All these operations require strict observation of adequate safety measures: individual protection garments, compliance with all industry regulations, compliance with applicable local regulations and using common sense. 18.3 - Level 3 (or higher) maintenance See note below. The maintenance at this level requires specific skills/approval/tools and know-how and only the manufacturer, his repre-sentative or authorised agent are permitted to carry out these operations. These maintenance operations concern for example: • A major component replacement (compressor, evaporator), • Any intervention on the refrigerant circuit (handling refrigerant), • Changing of parameters set at the factory (application change), • Removal or dismantling of the HVAC unit, • Any intervention due to a missed established maintenance operation, • Any intervention covered by the warranty. Note: Any deviation or non-observation of these maintenance criteria will render the guarantee conditions for the HVAC unit nul and void, and the manufacturer, Carrier France, will no longer be held responsible. 18.4 - Tightening torques for the main electrical connections Component DesignationValue in the unit (Nm) M12 screw on bus bar, customer connection 80 Soldered screw PE, customer connection 80 Tunnel terminal screw, fuse holder Fu- 3-3.5 Tunnel terminal screw, compressor contactor KM1-->KM12 3-4.5 Brass screw M6, compressor earth EC- 5 Screw M6, compressor connection EC- 5 Tunnel terminal screw, disconnects QM- 0.8-1.2 Screw M6, earth power distribution 10 18.5 - Tightening torques for the main bolts and screws Screw type Used forValue (Nm) Metal screw D=4.8 Condensing module, housing supports 4.2 Screw H M8 Condensing module, compressor fixing 18 Taptite screw M10 Condensing module, chassis - structure fixing 30 Taptite screw M6 Piping support, cowling 7 Screw H M8 Piping clip 12 Screw H M6 Piping clip 10 Nut H M10 Compressor chassis 30 18.6 - Condenser coil We recommend, that finned coils are inspected regularly to check the degree of fouling. This depends on the environment where the unit is installed, and will be worse in urban and industrial installations and near trees that shed their leaves. For coil cleaning, two maintenance levels are used, based on the AFNOR X60-010 standard: