11. STANDARD ADJUSTMENTS 11-14. Adjusting the work clamp lift amount The maximum lift amount for the work clamp (2) is 30 mm above the top of the needle plate. Max. 30mm 5018Q 4052M 1. Turn on the air, and then turn on the power switch. 2. Depress the work clamp switch (1) to raise the work clamp (2). 3. Loosen the two bolts (4) of the work clamp lifter lever (3), and then move the work clamp lifter lever (3) up or down to adjust the lift amount. 11-15. Adjusting the air pressure Lift up the handle (2) of the regulator (1) and then turn it to adjust the air pressure to 0.5 MPa. After adjustment is complete, push the handle (2) downward to lock it. 3975M 65 BAS-342G