Download DeWalt DG3000 Specifications
Transcript
Power Outage | Grid Failure | Inclement Weather Milbank Power generators Generator Product Catalog 2 milbank overview | About Milbank | EmPOWERing the Future Milbank Manufacturing Co., a third-generation family-owned business, has been engineering and manufacturing electrical supplies, equipment and solutions for use by utilities, contractors, distributors and OEMs since its founding in 1927. Today, Milbank’s meter mounting equipment is the standard by which all others are measured. Our meter sockets and electrical enclosures can be found on homes, schools, businesses, factories, roadways, RV parks, arenas, and airports across North America. Consistent with our vision to remain at the forefront of power generation and distribution technology, and to honor our stewardship of the environment, Milbank launched its PowerGen™ division in 2009. The PowerGen™ product line—which features wind, solar, electric vehicle charging stations and generators—incorporates renewable energy sources and distributed power generation while helping to advance smart grid initiatives. Protection. Power. Peace of Mind. Our generator products include a comprehensive line of residential, commercial and industrial standby and portable power systems featuring best-in-class engines such as Briggs & Stratton, Honda and GM. To find a distributor near you, please call 877.483.5314 or visit us at milbankpowergen.com www.milbankpowergen.com product index by category 3 Home Standby Generators 7-20kW residential air-cooled...................................................................................................................................... 6 30-45kW commercial liquid-cooled............................................................................................................................. 7 Transfer switches and patented power management technology overview.............................................................. 8 Maintenance accessories............................................................................................................................................. 9 Industrial Generators Pramac GEW Series – UL-listed liquid propane / natural gas units.......................................................................... 12 Pramac GEW Series – UL-listed diesel units.............................................................................................................. 13 Pramac GSW Series – diesel units.............................................................................................................................. 14 Pramac GRW Series – towable units.......................................................................................................................... 15 Portable Generators Pramac Powermate Vx-POWER Series....................................................................................................................... 16 Briggs & Stratton Standard and Elite Series.............................................................................................................. 17 Pramac S Class............................................................................................................................................................ 18 Powermate Series...................................................................................................................................................19-20 DeWALT Series............................................................................................................................................................. 21 Detailed Specifications Charts Home Standby Generators and Transfer Switches..................................................................................................... 23 Pramac Industrial Generators – GEW Series.........................................................................................................24-25 Pramac Industrial Generators – GSW Series.........................................................................................................26-27 Pramac Industrial Generators – GRW Series.........................................................................................................28-29 Pramac Vx-POWER Series and Briggs & Stratton Standard and Elite Series............................................................ 30 Pramac S Class, Powermate and DeWALT Portables.................................................................................................. 31 Other Information Additional Information................................................................................................................................................ 32 Milbank OneSERT........................................................................................................................................................ 33 Frequently Asked Questions..................................................................................................................................34-35 www.milbankpowergen.com 4 INTRODUCTION FOR HOMEOWNERS Protect your family. When the power goes out, don’t be left in the dark. With Milbank Home Standby Generators, you’ll ensure the protection of your family and your possessions. www.milbankpowergen.com INTRODUCTION FOR HOMEOWNERS 5 Protect your home. Life, interrupted. A blizzard. A thunderstorm. A collision with an unsuspecting utility pole. A heat-wave induced brownout. An aging, and now blown, transformer down the street. A freezer full of steaks and ice cream in the garbage. A refrigerator full of food and drinks down the drain. No computer. No television. No alarm system. No lights, inside or out. It’s life, interrupted. It’s inconvenient, expensive, uncomfortable, and most importantly, may compromise our family’s safety. Life, uninterrupted. A home standy generator offers life, uninterrupted. A standby generator offers continuous, uninterrupted power in the event of an outage. The result: continuous comfort, convenience and safety. Eliminate one of life’s interruptions. Install a Milbank home standby generator today and ensure an uninterrupted tomorrow. Questions about how our home standby generators work? Check out the FAQs on pages 34-35. www.milbankpowergen.com 6 7-20kW SERIES air-cooled home standby generator systemS 7-10kW Home Standby Systems Automatic System Features Fully Automatic – Advanced electronics will detect a utility power outage and automatically start the generator whether you are home or away. Computer-Friendly Power – Advanced alternator technology provides safe and stable power for computers and other sensitive electronics. Continuous Fuel Supply – A permanent connection to natural gas or propane delivers uninterrupted performance with no messy gasoline storage and refueling. Strong Warranty – The 7kW units include a two-year warranty; the 10kW units include a three-year warranty. Contemporary, Space-Saving Design – One of the most compact and functional designs on the market provides for location flexibility and an attractive, subtle yard presence. Quiet Operation – Engineered air passages, an automotive-style exhaust system and acoustic foam dampeners ensure 50% quieter operation than most portables. Durable Outdoor Enclosure – Each system features professional rust-proofing and premium automotive paint for maximum durability and all-weather protection. Turnkey Extras – Automatic systems include a battery charger, hour meter, and installation pad. The engine also comes pre-filled with synthetic oil and is pre-run and tested at the factory, saving you time and money. Remote System Status Monitor This 8-fault remote status monitoring system is a standard, preventative accessory that provides customers with peace of mind knowing their generator is always operating correctly. Included with all Milbank generators. Accessories Models MG07002 – 7kW MG10001 – 10kW Power Management System Enhancement: Model MG0501440 Featuring patented computer-controlled technology, this Power Management System upgrade further expands your generator’s range and performance by automatically prioritizing and managing an additional 4 high-demand 240V appliances. Cold Weather Package: Model MG111102 An oil heater and battery warmer are both thermostatically controlled to heat up when the temperature drops, ensuring smooth starting and engine operation. Items also available separately:. Battery Warmer Only: Model MG240100. Oil Heater Only: Model MG240101 (included on 7kW model) Maintenance Kit Model MG070022 (7kW), MG101222 (10kW) Includes special UL air filter, pre-cleaner, spark plugs, oil filter, and synthetic oil. 12-20kW Home Standby Systems Automatic System Features Fully Automatic – Advanced electronics will detect a utility power outage and automatically start the generator whether you are home or away. Continuous Fuel Supply – A permanent connection to natural gas or propane delivers uninterrupted performance with no messy gasoline storage and refueling. Vanguard™ V-Twin Engines – An industry leading commercial grade Big Block™ air-cooled engine powered by Briggs & Stratton provides powerful, quiet, durable performance for large, power hungry homes – perfect for years of heavy-duty standby power. Models MG12001 – 12kW MG15001 – 15kW MG20002 – 20kW Quiet Operation – Engineered air passages, an automotive-style exhaust system and acoustic foam dampeners ensure quiet operation. Durable Outdoor Enclosure – Features heat/rust proof polymer vents and louvers, rounded corners and a 3-step automotive rust proofing & wet coat paint process for years of durable outdoor protection – perfect for extreme weather and salt air conditions. Four-Year Warranty – The best comprehensive parts and labor warranty in the industry. Turnkey Extras – Automatic systems include battery charger, hour meter, installation pad. The engine comes pre-filled with synthetic oil and is pre-run at the factory, saving time and money. Remote System Status Monitor: All models This 8-fault remote status monitoring system is a standard, preventative accessory that provides customers with peace of mind knowing their generator is always operating correctly. Included with all Milbank generators. Accessories Power Management System Enhancement: Model MG0501440 Featuring patented computer-controlled technology, this Power Management System upgrade further expands your generator’s range and performance by automatically prioritizing and managing an additional 4 high-demand 240V appliances. Cold Weather Package: Model MG111102 An oil heater and battery warmer are both thermostatically controlled to heat up when the temperature drops, ensuring smooth starting and engine operation. Items also available separately:. Battery Warmer Only: Model MG240100. Oil Heater Only: Model MG240101 Maintenance Kit Model MG101222 (12kW), MG151822 (15-20kW) Includes special UL air filter, pre-cleaner, spark plugs, oil filter, and synthetic oil. See Specifications Chart on page 23 for more information. www.milbankpowergen.com 30-45kW SERIES liquid-cooled home standby generator systemS 7 30-45kW Home Standby Systems Automatic System Features Fully Automatic – Advanced electronics will detect a utility power outage and automatically start the generator whether you are home or away. GM Vortec Engine – Tested and approved on trucks and SUVs, world class 4 and 8 cylinder GM Vortec engines provide sophisticated yet extremely durable industrial grade power perfect for the high power demands of most larger homes. Computer-Friendly Power – A long life, commercial grade 4-pole 1800 RPM alternator provides robust, quiet, ultra smooth electricity, perfect for larger ‘smart’ homes. Commercial Four-Year Warranty – The best comprehensive parts and labor warranty in the industry. Quiet Operation – Engineered air flow, an automotive-style exhaust system, acoustic foam dampeners, and low 1800 RPM engine ensure quiet operation. Durable All-Climate Enclosure – The durable storm grey steel enclosure is powder coated for excellent adhesion and improved resistance to chipping, abrasion and corrosion - perfect for years of all-season outdoor protection. Turnkey Extras – Each system includes a battery charger and hour meter. The engine also comes pre-filled with synthetic oil, ethylene glycol long-life coolant and is pre-run at the factory, saving you time and money. Remote System Status Monitor: All models This 8-fault remote status monitoring system is a standard, preventative accessory that provides customers with peace of mind knowing their generator is always operating correctly. Included with all Milbank generators. Models MG30001 – 30kW MG45001 – 45kW Accessories Power Management System Enhancement: Model MG0501440 Featuring patented computer-controlled technology, this Power Management System enhancement further expands your generator’s range and performance by automatically prioritizing and managing four additional high-demand 240V appliances. Maintenance Kit Model MG300022 (30kW), MG450022 (45kW) Includes special UL air filter, pre-cleaner, spark plugs, oil filter, and synthetic oil. See Specifications Chart on page 23 for more information. www.milbankpowergen.com 8 Transfer switches and patented power management Automatic Transfer Switches Automatic System Features Fully Automatic – All Milbank transfer switches monitor utility and generator voltages and will automatically connect to the appropriate source of power. 100 and 200 amp switches are capable of “whole house” power transfer in residential/small business applications. Power Management Technology – During a power outage, most people think they have to go without central air conditioning to weather the storm. Keep your cool with patented computercontrolled transfer switches featuring the AC Power Control Module that manage up to two central air conditioners while safeguarding against power overload. The size of your generator dictates the level of comfort provided by this feature. Models MG0503120 – 50A, 12 circuits MG1003162 – 100A, 16 circuits MG1003002 – 100A MG2003002 – 200A MG1003992 – 100A, SE Rated MG2003992 – 200A, SE Rated MG2003993 – 200A, SE Rated (liquid cooled models only) Lightweight/Ease of Installation – Efficient component selection has resulted in switch gear optimization for a lightweight product solution to residential/small business installations. Five wires – three 120/240 VAC and two utility supply wires (for battery charger and optional battery warmer and oil heater) also allow for efficient one person installation. EEPROM (Electronic Program Read-Only Memory) – All transfer switches feature non-volatile memory, so when the power goes out, the transfer switch “remembers” its programming once power is restored. The switch never has to be programmed or reprogrammed once it is installed. 12kW – One 4-Ton AC. 15kW – Two 4-Ton ACs. 20kW – Two 5-Ton ACs Variable Engine Warm-Up – All of our switches feature both 20-second and 50-second warm-up options: 20 seconds for warm weather starts or a 50-second setting when the generator requires additional start time in colder climates. Exclusive Design – Each transfer switch is UL approved, custommade and dedicated exclusively for Milbank, reducing overall cost and giving you exactly what you need for your home or small business. Safety Features – All transfer switches are solenoid-operated from utility or generator inputs and contain electrical interlock switches to eliminate the possibility of dangerous back-feed to a line during an outage. Computer Friendly – All transfer switches feature Automatic Voltage Regulation to ensure a safe and stable sine wave to sensitive electronics.. Patented Power Management Technology All of our 100 amp and 200 amp automatic transfer switches that accompany our residential home standby generators come standard with our patented power management technology. This technology is leading the industry in meeting NEC 702, allowing homeowners wholehouse managed power with a smaller, more efficient generator systems and lowering overall installation costs. HOW IT WORKS Our power management system intelligently monitors the load the generator is providing when utility power is lost and waits until enough power is available to start higher wattage loads. When higher wattage appliances (most common is central air conditioning systems) want to start up, they send a signal to the automatic transfer switch. By using a set of current transformers, we can monitor the load the generator is producing to the home. If the generator is over a predetermined capacity, the transfer switch will prevent these higher wattage loads from starting and check back every five minutes waiting until enough power is available. Electrical loads can be intelligently managed with Milbank’s automatic transfer switches and power management technology. This will allow the homeowner to maximize the output of a smaller generator, which will reduce total cost of installation, lower fuel consumption, and reduce emissions. Power Management System Enhancement Featuring patented computer-controlled technology, this Load Control Center upgrade further expands your generator’s range and performance by automatically prioritizing and managing an additional four high-demand 240V appliances. Model MG0501440 Note: Automatic Transfer Switches are compatible only with home standby generator models. See Specifications Chart on page 23 for more information. www.milbankpowergen.com Home standby generator system maintenance accessories 9 Maintenance Accessories Cold Weather Package An oil heater and battery warmer are both thermostatically controlled to heat up when the temperature drops, ensuring smooth starting and engine operation. Items also available separately. Model Package – MG111102 Battery warmer only – MG240100 Oil heater only – MG240101 Maintenance Kits Includes special UL air filter, pre-cleaner, spark plugs, oil filter and synthetic oil. 7kW Series Model MG070022 10-12kW Series Model MG101222 15-20kW Series Model MG151822 Model 7kW series – MG070022 10-12kW series – MG101222 15-20kW series – MG151822 30kW series – MG300022 45kW series – MG450022 www.milbankpowergen.com 10 INTRODUCTION FOR CONTRACTORS AND OWNERS Giving you the power Milbank offers a complete line of industrial generators that give you the power you need to get the job done, whether it’s at a construction site or at the finished retail location. www.milbankpowergen.com INTRODUCTION FOR CONTRACTORS AND OWNERS 11 to get the job done. There’s work to be done. With an industrial generator on duty, it’s better than business as usual. Powerful, reliable and safe, our industrial generators eliminate the uncertainty of power outages and their costly impact to operations and the bottom line. Whether a retail storefront, multi-story office complex or a job trailer, Milbank offers industrial generators that give you the power to get the job done. www.milbankpowergen.com GASEOUS UNITS 12 INDUSTRIAL GENERATORS Industrial Generators Liquid Propane / Natural Gas System Features Options Available • Easy access for maintenance Transfer Switch • Safety guards for all electrical connections and moving parts Coolant Heater • Lockable latches Permanent Magnet Excitation • Engineered vibration dampening system Battery Warmer • Rugged base frame for versatile application NFPA 110 Compliance • Easy access display of all critical genset measures • Clean power with the Marathon alternator Configurations Available • Regulator provides 0.5% voltage regulation Models GEW25G GEW30G GEW40G GEW50G GEW65G GEW75G GEW100G GEW120G GEW160G GEW175G • Heavy duty GM Vortec engine Open Set • EPA emissions compliant Weather Enclosure • Integral mechanical radiator Soundproof Enclosure • 1-year warranty Parallel Capable Any Single Phase or Three Phase Voltage 50 Hz by Special Order Model Number Standby (kVA) - 1 Phase 240V LPG NG Standby (kVA) - 3 Phase 208V Standby (kVA) - 3 Phase 480V LPG NG LPG NG GEW25G 19.0 19.0 25.0 25.0 25.0 25.0 GEW30G 25.0 25.0 31.3 31.3 31.3 31.3 GEW40G 30.0 28.0 37.5 35.0 37.5 35.0 GEW50G 41.0 40.0 50.0 50.0 50.0 50.0 GEW65G 50.0 50.0 65.0 65.0 65.0 65.0 GEW75G 60.0 58.0 77.5 75.0 77.5 75.0 GEW100G 75.0 75.0 100.0 100.0 100.0 100.0 GEW120G 98.0 95.0 125.0 118.8 125.0 118.8 GEW160G 115.0 125.0 143.8 156.3 143.8 156.3 GEW175G 125.0 140.0 156.3 175.0 156.3 175.0 See Specifications Chart on page 24 for more information. www.milbankpowergen.com DIESEL UNITS INDUSTRIAL GENERATORS 13 Industrial Generators Diesel Units System Features Options Available • Easy access for maintenance Transfer Switch • Safety guards for all electrical connections and moving parts Base Tanks • Lockable latches Coolant Heater • Engineered vibration dampening system Permanent Magnet Excitation • Rugged base frame for versatile application Battery Warmer • Easy access display of all critical genset measures NFPA 110 Compliance • Clean power with the Marathon alternator • Regulator provides 0.5% voltage regulation • Heavy duty John Deere engine Configurations Available • Tier III EPA emissions compliant Open Set • Complete with engine fluids Weather Enclosure • 1-year warranty Soundproof Enclosure Models GEW30J GEW40J GEW50J GEW65J GEW75J GEW100J GEW125J GEW160J GEW190J GEW220J GEW260J Parallel Capable Any Single Phase or Three Phase Voltage 50 Hz by Special Order Model Number Standby (kVA) - 1 Phase 240V Standby (kVA) - 3 Phase 208V Standby (kVA) - 3 Phase 480V Diesel Diesel Diesel GEW30J 25.0 31.3 31.3 GEW40J 30.0 37.5 37.5 GEW50J 45.0 52.5 52.5 GEW65J 50.0 65.0 65.0 GEW75J 60.0 65.0 65.0 GEW100J 75.0 100.0 100.0 GEW125J 100.0 125.0 125.0 GEW160J 125.0 156.0 156.0 GEW190J 155.0 188.8 193.8 GEW220J 175.0 220.0 225.0 GEW260J 210.0 262.5 262.5 See Specifications Chart on page 25 for more information. www.milbankpowergen.com GSW SERIES 14 INDUSTRIAL GENERATORS Industrial Generators GSW Series System Features Automatic Control Panel (ACP) • STAMFORD Alternator Automatic control panel mounted on the genset, complete with digital control unit AC01 for monitoring, control and protection of the generating set. • Water-Cooled • Automatic Controller • Internal Residential Muffler • Detachable Central Lifting Point • Completely Sealed Drip Pan • Complete with Engine and Battery Liquids • Manual Oil Drain Pump • Heavy Duty Galvanized Skids (Optional) • Moveable Baseframe Models GSW15Y (Yanmar) GSW25Y (Yanmar) GSW35Y (Yanmar) GSW50Y (Yanmar) • Standard 8-Hour Tank • EPA Emissions Compliant • 1-year warranty Instrumentation (Digital) – Generator set voltage (3 phases), mains voltage, generator set frequency, generator set current (3 phases), battery voltage, power (kVA - kW - kVAr), power factor, hour counter, engine RPM, fuel level (%), engine temperature. Commands and Others – Six settings (automatic test, automatic starting, engine locked, mains contactor forced, manual start, genset contactor forced); emergency stop button; remote start capable; acoustic alarm; integrated battery charger. Protections with Alarm – Engine protection (low fuel level, low oil pressure, high engine temperature); genset protection (under/ over voltage, overload, under/over frequency, start failure, under/ over battery voltage, battery charge failure). Protections with Shutdown – Engine protection (low fuel level, low oil pressure, high engine temperature); genset protection (under/over voltage, overload, under/over battery voltage, battery charge failure); circuit breaker and differential protection (optional). Output and Sockets – Power cables connected to terminals board (external), main lugs. * Manual Starting: the preheating period begins automatically when this position is selected. It is necessary to select this position again to enable the preheating period one more time. Models GSW60P (Perkins) GSW70P (Perkins) GSW90P (Perkins) GSW120P (Perkins) GSW160P (Perkins) GSW170P (Perkins) GSW200P (Perkins) Note: Trailer sold separately. See Specifications Chart on page 26-27 for more information. www.milbankpowergen.com GRW SERIES INDUSTRIAL GENERATORS 15 Industrial Generators GRW Series System Features Manual Control Panel (MCP) • Heavy Duty Compact Construction Manual control panel mounted on the genset, with analog instrumentation and protected through door with lockable handle. • Designed for Long Running Time • Lockable Door with Access to Emergency Stop • Individual Modules for Each Section • Quiet Operation • Easy-To-Use Control Panel • Multi-Voltage • Ready for Manual or Auto-Start Operation • Battery Trickle Charger Included • Road-Tow Trailer Available (Optional, Sold Separately) • 1-year warranty Instrumentation (Analog) – Voltmeter, ammeter, frequency meter, hours-counter, fuel level indicator, oil pressure indicator, engine temperature indicator. Commands and Others – Start / stop selector switch with key, emergency stop button, potentiometer for adjusting the output voltage, six wire multipin connector for external remote start / stop signal and battery charger feeding. Protections with Alarm – Engine protection: low fuel level, low oil pressure, high engine temperature battery charge failure. Protections with Shutdown – Engine protection unit (MC-01): low fuel level, low oil pressure, high engine temperature, battery charger failure. Circuit breaker protection. Output – Power cables connected to terminals board (external). Output Receptacles – 2 x 120V 20A 2P+T NEMA (duplex w/ GFCI) 1 x 120V 30A 2P+T NEMA (twistlock). 1 x 240/120V 30A 2P+T NEMA (twistlock). 1 x 240/120V 50A 2P+T NEMA (twistlock). 1 x 240V 50A 3P+T NEMA (twistlock). Main lugs Models GSW15Y (Yanmar) GSW25Y (Yanmar) GSW35Y (Yanmar) GSW50Y (Yanmar) Models GSW60P (Perkins) GSW70P (Perkins) GSW90P (Perkins) GSW120P (Perkins) GSW160P (Perkins) GSW170P (Perkins) GSW200P (Perkins) Note: Trailer sold separately. See Specifications Chart on page 28-29 for more information. www.milbankpowergen.com VX POWER SERIES 16 PORTABLE GENERATORS Portable Generators Vx-POWER Series - Powered by 1,200 Rated Watts / 1,400 Surge Watts – Manual Start • Engine – Powermate OHV • Includes 12V battery charging cables • Voltage – 120V AC; 12 Volts DC • 1-year Warranty • Compact roll cage design • CSA Certified Model PM0101207 – 49-state compliant PC0101207 – CSA compliant 3,000 Rated Watts / 3,750 Surge Watts – Manual Start • Engine – Powermate OHV • Dual folding handles for easy storage • Voltage – 120V / 240V AC; 12 Volts DC • Includes hour meter and AVR • Compact roll cage design • 2-year Warranty • Mobility kit included with 8" never-flat wheels Model PM0103007 – 49-state compliant PMC103007 – CARB and City of Los Angeles compliant PC0103007 – CSA compliant 5,000 Rated Watts / 6,250 Surge Watts – Manual Start • Engine – Powermate OHV • Dual folding handles for easy storage • Voltage – 120V / 240V AC; 12 Volts DC • Includes hour meter and AVR • Compact roll cage design • 2-year Warranty • Mobility kit included with 10" never-flat wheels Model PM0105007 – 49-state compliant PMC105007 – CARB and City of Los Angeles compliant PC0105007 – CSA compliant 6,500 Rated Watts / 8,125 Surge Watts – Electric / Manual Start • Engine – Powermate OHV • Dual folding handles for easy storage • Voltage – 120V / 240V AC; 12 Volts DC • Includes hour meter and AVR • Compact roll cage design • Battery included • Mobility kit included with 10" never-flat wheels • 2-year Warranty Model PM0106507 – 6,500 Rated Watts / 8,125 Surge Watts PMC106507 – CARB and City of Los Angeles compliant PC0106507 – CSA compliant www.milbankpowergen.com See Specifications Chart on page 30 for more information. briggs & stratton portable generators 17 Portable Generators Standard & Elite Series - Powered by Briggs & Stratton Briggs & Stratton generators offer a premium combination of power, performance and value you would only expect from the market leader. Briggs & Stratton is North America’s largest supplier of portable generators. 5,500 Watt – Manual Start • Briggs & Stratton 1650 Series OHV Engine • Rubber outlet covers • 5 gallon fuel tank - 10 hours of run time @ 50% load • 2-year limited warranty • Hour meter • CSA Certified • Never-go-flat wheels Model MGP5502 – 5,500 Watts 7,000 Watt – Electric Start • Briggs & Stratton 2100 Series OHV Engine • Never-go-flat wheels • 7 gallon fuel tank - 9 hours of run time @ 50% load • Rubber outlet covers • Hour meter • 3-year limited warranty • Key electric start • CSA Certified • Battery included Model MGP7000 – 7,000 Watts 8,000 Watt – Electric Start • Briggs & Stratton 2100 Series OHV Engine • Never-go-flat wheels • 7 gallon fuel tank - 9 hours of run time @ 50% load • Rubber outlet covers • Hour meter • 3-year limited warranty • Key electric start • CSA Certified • Battery included Model MGP8002 – 8,000 Watts See Specifications Chart on page 30 for more information. www.milbankpowergen.com PRAMAC s class 18 portable generators Portable Generators S Class Generators - Powered by Pramac Product Features Model 2,600 Rated Watts / 3,100 Surge Watts - Manual Start PD292MHI003 - 49 State Compliant • Honda GX series engines • Voltage selector switch • Voltage – 60 Hz / 120 / 240 • Easy-to-read electrical panel • Rugged frame design • Optional wheel kit • Large fuel tank with gauge • Fully EPA, CARB and CSA compliant • Fuel valve • 2-year (3-year on engine) warranty • Idle control • Batteries not included • Hour meter Light Tower Kits Model 3,800 Rated Watts / 4,000 Surge Watts - Manual Start PD382MHI001 - CARB Compliant PD382MHI002 - 49 State Compliant Model Number PY000A00092 PY000A00094 PY000A00098 Power (Watts) 2,000 4,000 6,000 Lamp Power (Lumens) 38,000 88,000 132,000 Lit Area (FT2) 8,000 16,000 24,200 Lamp Type Halogen Voltage & Frequency 240V / 60 Hz Lamp Autonomy 2000 Hours Mast Pneumatic Telescopic mast sections Max Height Three 13.8 feet Operation Temperature Protection Level 266° F IP 55 Model 5,300 Rated Watts / 6,000 Surge Watts - Manual Start PD532MHI001 - CARB Compliant PD452MHI004 - 49 State Compliant Model 6,100 Rated Watts / 7,200 Surge Watts - Electric Start PD612MHB001 - CARB Compliant PD612MHB002 - 49 State Compliant Model 11,700 Rated Watts / 14,000 Surge Watts - Electric Start PD123MHBZ04 - CARB Compliant See Specifications Chart on page 31 for more information. www.milbankpowergen.com powermate series portable generators 19 Portable Generators Powermate Series - Powered by Pramac 5,000 Rated Watts / 6,250 Surge Watts • Engine – Subaru EX30 • Long life alternator • Recoil start as a backup • Full tubing frame for added protection • Fuel type – Gasoline • Wheel kit includes 10" wheels • AC Voltage – 120V/240V • Includes battery and charger • AC Frequency – 60 Hz • 2-year warranty Model PM0435006 – Electric Start 5,700 Rated Watts / 7,125 Surge Watts • Engine – Yamaha MZ 300 • Receptacle debris cover for in-use operation • Fuel type – Gasoline • Wheel kit – included with 14" wheels • AC Voltage – 120V/240V • Includes AVR, one quart of engine oil, 25 foot 30A generator cord, CordKeepers™ • AC Frequency – 60 Hz • Long life alternator • 2-year warranty Model PM0675700 – Manual Start 6,800 Rated Watts / 8,500 Surge Watts • Engine – Yamaha MZ 360 • Wheel kit – included with 10" wheels • Fuel type – Gasoline • Includes AVR and one quart of engine oil • AC Voltage – 120V/240V • 2-year warranty • AC Frequency – 60 Hz • Electric start unit includes recoil start as backup and a 12V 18AH battery & 12V battery charger • Long life alternator • Full tubing frame with added protection Model PM0676800 – Electric Start PM0676801 – Manual Start See Specifications Chart on page 31 for more information. www.milbankpowergen.com powermate series 20 portable generators Portable Generators Powermate Series - Powered by Pramac 7,000 Rated Watts / 8,750 Surge Watts • Engine – Honda GX390 • Full tubing frame for added protection • Fuel type – Gasoline • Wheel kit – included with 10" wheels • AC Voltage – 120V/240V • Includes AVR & CordKeepers™ • AC Frequency – 60 Hz • 3-year warranty Model PM0497000.04 – Manual Start 8,000 Rated Watts / 10,000 Surge Watts • Engine – Kohler PS-44550 • Battery included • Electric or recoil start • Wheel kit – included with 10” wheels • Fuel type – Gasoline • Includes (2) one quart bottles of engine oil, AVR, 12V 18AH battery & CordKeepers™ • AC Voltage – 120V/240V • AC Frequency – 60 Hz • 3-year warranty • Full tubing frame for added protection Model PM0418000 – Electric Start 12,500 Rated Watts / 15,625 Surge Watts • Engine – Subaru EH65 • Battery included • Fuel type – Gasoline • Idle control • AC Voltage – 120V/240V • Wheel kit includes 13" wheels • AC Frequency – 60 Hz • Includes (2) one-quart bottles of engine oil, 12V 34AH battery and CordKeepers™ • Full tubing frame with added protection • Built-in lifting points on frame • 3-year warranty Model PM0601250 – Electric Start See Specifications Chart on page 31 for more information. www.milbankpowergen.com DEWALT SERIES PORTABLE GENERATORS 21 Portable Generators DeWALT Series - Powered by Pramac 3,000 Max Watts / 2,920 Rated Watts – Commercial Generator • Engine – DeWALT 196cc (6.5HP) OHV engine • Low oil shut-off • Maintenance free, brushless DeWALT alternator • 8-hour run-time at 50% max output • High amp surge capacity • 3.3 gallon fuel tank capacity • Super quiet muffler Model DG3000 – 49-state compliant DG3000C – California compliant 4,400 Max Watts / 4,180 Surge Watts – Commercial Generator • DeWALT 18-volt battery start (battery and charger included) • Worksite tested frame with panel protections bars • Engine – DeWALT 270cc (9HP) OHV engine • Super quiet muffler reduces engine noises • 20% more starting watts than generators in its class • Idle control saves fuel and reduces noise • Proper 120V and 240V outlets for jobsite applications • Low oil shut-off provides greater pump protection Model DG4400B – 49-state compliant DG4400BC – California compliant 6,300 Max Watts / 5,950 Rated Watts – Commercial Generator • DeWALT 18-volt battery start (battery and charger included) • Worksite tested frame with panel protections bars • Engine – DeWALT 389cc (13HP) OHV engine • Super quiet muffler reduces engine noises • 20% more starting watts than generators in its class • Idle control saves fuel and reduces noise • Proper 120V and 240V outlets for jobsite applications • Low oil shut-off provides greater pump protection Model DG6300B – 49-state compliant 7,000 Max Watts / 6,500 Rated Watts – Commercial Generator • DeWALT 18-volt battery start (battery and charger included) • Worksite tested frame with panel protections bars • Engine – DeWALT 270cc (9HP) OHV engine • Super quiet muffler reduces engine noises • 20% more starting watts than generators in its class • Idle control saves fuel and reduces noise • Proper 120V and 240V outlets for jobsite applications • Low oil shut-off provides greater pump protection Model DG7000B – 49-state compliant See Specifications Chart on page 31 for more information. www.milbankpowergen.com 22 Product specifications Technical Specifications www.milbankpowergen.com PRODUCT SPECIFICATIONS 23 Home Standby Generators Model Number Watts LP/NG MG07002 - 7kW MG10001 - 10kW MG12001 - 12kW MG15001 - 15kW MG20002 - 20kW MG30001 - 30kW MG45001 - 45kW 7,000W (LP) / 6,000W (NG) 10,000W (LP) / 9,000W (NG) 12,000W (LP) / 11,000W (NG) 15,000W (LP) / 14,000W (NG) 20,000W (LP) / 18,000W (NG) 30,000W (LP) / 27,000W (NG) 45,000W (LP) / 45,000W (NG) 504cc Extended Life Series™ 570cc Vanguard™ V-Twin 627cc Vanguard™ V-Twin 895cc Vanguard™ V-Twin 993cc Vanguard™ V-Twin GM Vortec 3.0L Inline 4 Cylinder GM Vortec 5.0L V8 Operation Engine Fully Automatic Operating RPM Voltage Amps LP/NG 29.1 (LP) / 25 (NG) 3600 1800 120/240V AC, Single Phase, 1.0 pf 120/240V AC, Single Phase,. Electronic Regulation 41.7 (LP) / 37.5 (NG) Alternator Type Oil Warmer 50 (LP) / 45.8 (NG) 62.5 (LP) / 58.3 (NG) 187.5 (LP) / 187.5 (NG) 125 (LP) / 112.5 (NG) Automatic Voltage Regulator 4-Pole, Brushless Yes (included) Yes (optional - sold separately) Battery Warmer Yes (optional - sold separately) Full Pressure Lubrication No Yes Fuel Type Fuel Consumption (at 1 ⁄2 load) 83.3 (LP) / 75 (NG) Propane (LP vapor), Natural Gas 33 FT3/HR LP, 80 FT3/HR NG 35 FT3/HR LP, 84 FT3/HR NG 41 FT3/HR LP, 102 FT3/HR NG 56 FT3/HR LP, 126 FT3/HR NG Weekly Exerciser 71 FT3/HR LP, 160 FT3/HR NG 92 FT3/HR LP, 259 FT3/HR NG 178 FT3/HR LP, 483 FT3/HR NG 65 dB 66 dB Yes Sound Attenuation Lo Tone™ Muffler Sound Rating (normal operation) 74 dB Sound Shield™ Technology 71 dB 65 dB 65 dB 68 dB Battery Charger Yes Overcrank Protection Yes Diagnotic Alerts with Remote System Status Low Oil Pressure, Fail to Start, Low Frequency, Engine Overspeed, Low Voltage, Low Battery, High Temperature, Transfer Switch Dimensions (L x W x H) 32" x 32.25" x 38.5" 48.69" x 33.75" x 31.63" 84.5" x 39.5" x 41.5" 98.5" x 39.5" x 44.5" Weight (generator only) 299 lbs. 335 lbs. 470 lbs. 544 lbs. 572 lbs. 1,800 lbs. 2,100 lbs. Main Line Circuit Breaker 30 Amp 50 Amp 60 Amp 70 Amp 100 Amp 150 Amp 200 Amp Battery Requirements** 33 Amp Hour, 12 Volt DC, 350 CCA, AGM 50 Amp Hour, 12 Volt DC, 600 CCA, AGM Total Harmonic Distortion Limited Warranty 55 Amp Hour, 12 Volt DC, 650 CCA, AGM Less than 5% 2 Years 3 Years 4 Years Transfer Switches Model Number MG0503120 MG1003162 MG1003002 MG2003002 MG1003992 MG2003992 MG2003993* Circuits 12 16 Amps 50A 100A 100A 200A 100A 200A 200A Service Entrance Disconnect No No No No Yes Yes Yes 14.25" x 6" x 21" 14” x 6” x 24” 12” x 6” x 16” 12” x 6” x 22” 16” x 7” x 22” 16” x 7” x 30” 33” x 10.25” x 19” 29 lbs. 39 lbs. 24 lbs. 37 lbs. 38 lbs. 64 lbs. 64 lbs. Dimensions (L x W x H) Weight Common Features Power Mgmt. Method Whole House 120/240 Voltage, 2 Poles, 50/60 Frequency, NEMA 3R Enclosure, UL 1008 Listed ACCM-II, Patented A/C Power Control Module™ NOTE: Other manufacturers may not be compatible with Milbank’s generators or automatic transfer switches. * For liquid-cooled models only. **Battery not included www.milbankpowergen.com Product specifications Industrial Generators 480V (3 Phase) GEW Series | Liquid Propane / Natural Gas Units Model Number GEW25G PRIME POWER PRP (NG) 20kW (25kVA) EMER POWER LTP (NG) 20kW (25kVA) PRIME POWER PRP (LPV) 20kW (25kVA) EMER POWER LTP (LPV) 20kW (25kVA) GEW30G 23kW (28.8kVA) 25kW (31.3kVA) 23kW (28.8kVA) 25kW (31.3kVA) GEW40G 23kW (28.8kVA) GEW50G 35 kW (43.8kVA) GEW65G 42.4kW (53.0kVA) GEW75G GEW100G GEW120G 48kW (60kVA) 72kW (90kVA) 76kW (95kVA) 28kW (35kVA) 40kW (50kVA) 52kW (65kVA) 60kW (75kVA) 80kW (100kVA) 25kW (31.3kVA) 30kW . (37.5 kVA) 35 kW (43.8kVA) 42.4kW (53.0kVA) 40kW (50kVA) 52kW (65kVA) 51kW (63.8kVA) 62kW (77.5kVA) 80kW (100kVA) 95kW (118.8kVA) 85kW (106.3kVA) 100kW (125kVA) 208V (3 Phase) Voltage Frequency Power factor 72kW (90kVA) GEW160G 105kW (131.3kVA) 125kW (156.3kVA) 96kW (120kVA) 115kW (143.8kVA) GEW175G 130kW (162.5kVA) 140kW (175kVA) 115kW (143.8kVA) 125kW (156.3kVA) 105kW (131.3kVA) 125kW (156.3kVA) 96kW (120kVA) 115kW (143.8kVA) 130kW (162.5kVA) 140kW (175kVA) 115kW (143.8kVA) 125kW (156.3kVA) 105kW (105kVA) 125kW (125kVA) 480V 60 Hz 0.8 Cos PRIME POWER PRP (NG) 20kW (25kVA) EMER POWER LTP (NG) 20kW (25kVA) PRIME POWER PRP (LPV) 20kW (25kVA) EMER POWER LTP (LPV) 20kW (25kVA) 23kW (28.8kVA) 25kW (31.3kVA) 23kW (28.8kVA) 25kW (31.3kVA) 23kW (28.8kVA) 35 kW (43.8kVA) 42.4kW (53.0kVA) 48kW (60kVA) 72kW (90kVA) 76kW (95kVA) 28kW (35kVA) 40kW (50kVA) 52kW (65kVA) 60kW (75kVA) 80kW (100kVA) 25kW (31.3kVA) 30kW . (37.5 kVA) 35 kW (43.8kVA) 42.4kW (53.0kVA) 40kW (50kVA) 52kW (65kVA) 51kW (63.8kVA) 62kW (77.5kVA) 80kW (100kVA) 95kW (118.8kVA) 85kW (106.3kVA) 100kW (125kVA) Voltage Frequency Power factor 240V (1 Phase) 24 72kW (90kVA) 208V 60 Hz 0.8 Cos PRIME POWER PRP (NG) 19kW (19kVA) 23kW (23kVA) 23kW (23kVA) 31kW (31kVA) 42.5kW (42.5kVA) 48kW (48kVA) 70kW (70kVA) 76kW (76kVA) EMER POWER LTP (NG) 19kW (19kVA) 25kW (25kVA) 28kW (28kVA) 40kW (40kVA) 50kW (50kVA) 58kW (58kVA) 75kW (75kVA) 95kW (95kVA) 51kW (51kVA) 70kW (70kVA) 85kW (85kVA) 96kW (96kVA) 60kW (60kVA) 75kW (75kVA) 98kW (98kVA) 115kW (115kVA) 130kW (130kVA) 140kW (140kVA) 115kW (115kVA) 125kW (125kVA) 121.3 x 48.0 x 72.0 2829 lbs 121.3 x 48.0 x 72.0 2978 lbs 121.3 x 48.0 x 72.0 3175 lbs 133.9 x 48.0 x 72.0 3433 lbs 127.3 HP 138.1 HP 767.4 ft3/hr 935.8 ft3/hr 8100cc 132.7 HP 154.2 HP 146.1 HP 179.6 HP 393.8 ft3/hr 440.2 ft3/hr 480.3 ft3/hr 536.8 ft3/hr 156.8 HP 183.6 HP 506.8 ft3/hr 618.0 ft3/hr PRIME POWER PRP (LPV) 19kW (19kVA) 23kW (23kVA) 25kW (25kVA) 35kW (35kW) 42.5kW (42.5kVA) EMER POWER LTP (LPV) 19kW (19kVA) 25kW (25kVA) 30kW (30kVA) 41kW (41kVA) 50kW (50kVA) Voltage Frequency Power factor Dimensions (LxWxH) Weight (dry) ENGINE Exhaust emissions Cooling system Speed Displacement Engine power PRP Engine power LTP Fuel cons. (75% load PRP) Fuel cons. (100% load PRP) Engine governor (standard) SYNCH. ALTERNATOR Insulation class Voltage regulation 81.9 x 36.2 x 46.9 1316 lbs 81.9 x 36.2 x 46.9 1358 lbs 48.3 HP 3000cc 41.6 HP 46.9 HP 263.5 ft3/hr 321.4 ft3/hr 81.9 x 36.2 x 46.9 1420 lbs 94.1 x 42.1 x 52.8 1678 lbs 48.3 HP 4300cc 55.0 HP 61.7 HP 188.2 ft3/hr 229.5 ft3/hr 240V 60 Hz 1.0 Cos 94.1 x 42.1 x 94.1 x 42.1 x 52.8 52.8 2030 lbs 2291 lbs GM Vortec Compliant Water 1800 rpm 5700cc 100.5 HP 108.6 HP 223.0 ft3/hr 608.1 ft3/hr 271.9 ft3/hr 741.6 ft3/hr Electronic Marathon Class H 0.5% Note: Technical characteristics listed are not inclusive of any product customizations and the producer reserves the right to modify them for innovations without prior notice. www.milbankpowergen.com PRODUCT SPECIFICATIONS 25 Industrial Generators GEW Series | Diesel Units Model Number 480V (3 Phase) PRIME POWER PRP EMER POWER LTP 208V (3 Phase) GEW40J 26kW (32.5kVA) 30kW (37.5kVA) GEW50J 36kW (45kVA) 42kW (52.5kVA) GEW65J 44kW (55kVA) 52kW (65kVA) GEW75J 44kW (55kVA) 52kW (65kVA) 23kW (28.8kVA) 25kW (31.3kVA) 26kW (32.5kVA) 30kW (37.5kVA) 36kW (45kVA) 42kW (52.5kVA) 44kW (55kVA) 52kW (65kVA) 44kW (55kVA) 52kW (65kVA) 23kW (23kVA) 25kW (25kVA) 26kW (26kVA) 30kW (30kVA) 45kW (45kVA) 45kW (45kVA) 42kW (42kVA) 50kW (50kVA) 50kW (50kVA) 60kW (60kVA) 81.9 x 35.8 x 46.9 1598 lbs 1649 lbs 1700 lbs Voltage Frequency Power factor PRIME POWER PRP EMER POWER LTP Voltage Frequency Power factor PRIME POWER PRP 240V (1 Phase) GEW30J 23kW (28.8kVA) 25kW (31.3kVA) EMER POWER LTP Voltage Frequency Power factor Dimensions (LxWxH) Weight (dry) DIESEL ENGINE Exhaust emissions Cooling system Speed Displacement Engine power PRP Engine power LTP Fuel cons. (75% load PRP) Fuel cons. (100% load PRP) Engine governor (standard) SYNCH. ALTERNATOR Insulation class Voltage regulation 94.1 x 42.1 x 53.1 1878 lbs 2033 lbs Tier IV I Compliant 2400cc 42.9 HP 73.7 HP 48.3 HP 80.4 HP 1.6 gal/h 1.8 gal/h 2.9 gal/h 2.6 gal/h 2.1 gal/h 2.3 gal/h 3.8 gal/h 3.5 gal/h Note: Technical characteristics listed are not inclusive of any product customizations and the producer reserves the right to modify them for innovations without prior notice. www.milbankpowergen.com 3050cc 87.1 HP 96.5 HP 3.4 gal/h 4.5 gal/h GEW100J GEW125J 72kW 90kW (90kVA) (112.5kVA) 80kW 100kW (100kVA) (125kVA) 480V 60 Hz 0.8 Cos 72kW 90kW (90kVA) (112.5kVA) 80kW 100kW (100kVA) (125kVA) 208V 60 Hz 0.8 Cos 70kW 90kW (70kVA) (90kVA) 75kW 100kW (75kVA) (100kVA) 240V 60 Hz 1.0 Cos 122.0 x 48.0 x 71.3 3078 lbs 3280 lbs John Deere Tier III Compliant Water 1800 RPM 4500cc 115.3 HP 143.4 HP 126.0 HP 158.2 HP 4.2 gal/h 5.5 gal/h 5.6 gal/h 7.3 gal/h Electronic Marathon Class H 0.5% GEW160J 110kW (137.5kVA) 124.8kW (156kVA) GEW190J 140kW (175kVA) 155kW (193.8kVA) GEW220J 170kW (212.5kVA) 180kW (225kVA) GEW260J 190kW (237.5kVA) 210kW (262.5kVA) 110kW (137.5kVA) 124.8kW (156kVA) 136kW (170kVA) 151kW (188.8kVA) 165kW (206.3kVA) 176kW (220kVA) 190kW (237.5kVA) 210kW (262.5kVA) 110kW (110kVA) 125kW (125kVA) 140kW (140kVA) 155kW (155kVA) 155kW (155kVA) 175kW (175kVA) 190kW (190kVA) 210kW (210kVA) 3909 lbs 134.3 x 48.0 x 72.0 4118 lbs 4438 lbs 4559 lbs 179.6 HP 197.1 HP 6.2 gal/h 8.3 gal/h 6800cc 215.8 HP 286.9 HP 237.3 HP 315.0 HP 7.8 gal/h 8.5 gal/h 10.2 gal/h 10.5 gal/h 11.3 gal/h 13.6 gal/h Product specifications Industrial Generators 208V (3 Phase) 480V (3 Phase) GSW Series | 15kW - 50kW Yanmar Series 240V (1 Phase) 26 Model Number PRIME POWER PRP EMER POWER LTP Voltage Frequency Power factor PRIME POWER PRP EMER POWER LTP Voltage Frequency Power factor PRIME POWER PRP EMER POWER LTP Voltage Frequency Power factor Tank capacity Autonomy (III) (75% PRP) Autonomy (III) (100% PRP) Dimensions (LxWxH) Weight (dry) DIESEL ENGINE Exhaust emissions Cooling system Speed Displacement Cylinders and disposition Aspiration Engine power PRP Engine power LTP Fuel cons (III) (75% load PRP) Fuel cons. (III) (100% load PRP) Specific consumption PRP Engine governor (standard) SYNCH. ALTERNATOR Power at 27ºC (480V) Power at 27ºC (208V) Power at 27ºC (240V) Insulation class Mechanical protection Voltage regulation GSW15Y 14 (17) kW (kVA) 15 (19) kW (kVA) 480/277 Volt 60 Hz 0.8 Cos 14 (17) kW (kVA) 15 (19) kW (kVA) 208/120 Volt 60 Hz 0.8 Cos 12.5 (12.5) kW (kVA) 14 (14) kW (kVA) 240/120 Volt 60 Hz 1 Cos 21 US Gallons 22 h 16.5 h 70.9" x 32.7" x 51.2" 1,544 lbs YANMAR 3TNV88 EPA IV Water 1800 rpm 100.2 cu. in. 3 line n° disp. Natural 20 bhp 22 bhp 0.9 gal/h 1.2 gal/h 0.397 lb/hph Mechanical STAMFORD BCI184E 24 (30) Kwe (kVA) 22 (28) Kwe (kVA) 13 (16) Kwe (kVA) H IP23 Electronic / 1.5% GSW25Y 18 (23) kW (kVA) 20 (25) kW (kVA) 480/277 Volt 60 Hz 0.8 Cos 18 (23) kW (kVA) 20 (25) kW (kVA) 208/120 Volt 60 Hz 0.8 Cos 17.5 (17.5) kW (kVA) 19 (19) kW (kVA) 240/120 Volt 60 Hz 1 Cos 21 US Gallons 16.5 h 12.4 h 70.9" x 32.7" x 51.2" 1,786 lbs YANMAR 4TNV88 EPA IV Water 1800 rpm 133.6 cu. in. 4 line n° disp. Natural 29 bhp 32 bhp 1.2 gal/h 1.7 gal/h 0.397 lb/hph Mechanical STAMFORD BCI184E (F, 1ph) 24 (30) Kwe (kVA) 22 (28) Kwe (kVA) 13 (16) Kwe (kVA) H IP23 Electronic / 1.5% GSW35Y 31 (39) kW (kVA) 32 (40) kW (kVA) 480/277 Volt 60 Hz 0.8 Cos 29 (36) kW (kVA) 30 (37) kW (kVA) 208/120 Volt 60 Hz 0.8 Cos 27.4 (27.4) kW (kVA) 30 (30) kW (kVA) 240/120 Volt 60 Hz 1 Cos 21 US Gallons 9.6 h 7.2 h 78.7" x 36.2" x 51.2" 2,099 lbs YANMAR 4TNV98 EPA IV Water 1800 rpm 202.5 cu. in. 4 line n° disp. Natural 55 bhp 60 bhp 2.2 gal/h 2.9 gal/h 0.363 lb/hph Electronic STAMFORD BCI184G (J, 1ph) 31 (39) Kwe (kVA) 29 (36) Kwe (kVA) 16 (20) Kwe (kVA) H IP23 Electronic / 1.5% GSW50Y 42 (52) kW (kVA) 42 (53) kW (kVA) 480/277 Volt 60 Hz 0.8 Cos 39 (49) kW (kVA) 40 (51) kW (kVA) 208/120 Volt 60 Hz 0.8 Cos 38 (38) kW (kVA) 42 (42) kW (kVA) 240/120 Volt 60 Hz 1 Cos 21 US Gallons 7.3 h 5.5 h 78.7" x 36.2" x 57.3" 2,258 lbs YANMAR 4TNV98T EPA IV Water 1800 rpm 202.5 cu. in. 4 line n° disp. Turbo 67 bhp 74 bhp 2.8 gal/h 3.8 gal/h 0.386 lb/hph Electronic STAMFORD BCI184J (UCI 224D, 1ph) 42 (52) Kwe (kVA) 39 (49) Kwe (kVA) 22 (27) Kwe (kVA) H IP23 Electronic / 1.5% Note: Technical characteristics listed are not inclusive of any product customizations and the producer reserves the right to modify them for innovations without prior notice. www.milbankpowergen.com PRODUCT SPECIFICATIONS 27 Industrial Generators 240V (1 Phase) 208V (3 Phase) 480V (3 Phase) GSW Series | 70kW - 200kW Perkins Series Model Number PRIME POWER PRP EMER POWER LTP Voltage Frequency Power factor PRIME POWER PRP EMER POWER LTP Voltage Frequency Power factor PRIME POWER PRP EMER POWER LTP Voltage Frequency Power factor Tank capacity Autonomy (III) (75% PRP) Autonomy (III) (100% PRP) Dimensions (LxWxH) Weight (dry) DIESEL ENGINE Exhaust emissions Cooling system Speed Displacement Cylinders and disposition Aspiration Engine power PRP Engine power LTP Fuel cons (III) (75% load PRP) Fuel cons (III) (100% load PRP) Specific consumption PRP Engine governor (standard) SYNCH. ALTERNATOR Power at 27ºC (480V) Power at 27ºC (208V) Power at 27ºC (240V) Insulation Mechanical protection Voltage regulation GSW70P 58 (73) kW (kVA) 64 (80) kW (kVA) 480/277 Volt 60 Hz 0.8 Cos 56 (70) kW (kVA) 58 (73) kW (kVA) 208/120 Volt 60 Hz 0.8 Cos 45 (45) kW (kVA) 50 (50) kW (kVA) 240/120 Volt 60 Hz 1 Cos 92 US Gallons 25.5 h 19.1 h 106.7" x 46.5" x 60.4" 3,019 lbs PERKINS 1104D-E44TG EPA III Water 1800 rpm 269.1 cu. in. 4 line n° disp. Turbo 87 bhp 97 bhp 3.6 gal/h 4.8 gal/h 0.383 lb/hph Mechanical STAMFORD UCI 224 E 64 (80) Kwe (kVA) 58 (73) Kwe (kVA) 36 (45) Kwe (kVA) H IP23 Electronic / 1.0% GSW90P 74 (93) kW (kVA) 82 (103) kW (kVA) 480/277 Volt 60 Hz 0.8 Cos 74 (92) kW (kVA) 82 (102) kW (kVA) 208/120 Volt 60 Hz 0.8 Cos 68 (68) kW (kVA) 74 (74) kW (kVA) 240/120 Volt 60 Hz 1 Cos 92 US Gallons 21.3 h 16 h 106.7" x 46.5" x 60.4" 3,281 lbs PERKINS 1104D-E44TAG1 EPA III Water 1800 rpm 269.1 cu. in. 4 line n° disp. Turbo-Intercooler 110 bhp 122 bhp 4.3 gal/h 5.8 gal/h 0.363 lb/hph Electronic STAMFORD UCI 274 C 110 (138) Kwe (kVA) 96 (120) Kwe (kVA) 54 (68) Kwe (kVA) H IP23 Electronic / 1.0% GSW120P 91 (114) kW (kVA) 100 (125) kW (kVA) 480/277 Volt 60 Hz 0.8 Cos 90 (113) kW (kVA) 96 (120) kW (kVA) 208/120 Volt 60 Hz 0.8 Cos 68 (68) kW (kVA) 74 (74) kW (kVA) 240/120 Volt 60 Hz 1 Cos 92 US Gallons 18.1 h 13.6 h 106.7" x 46.5" x 66.3" 3,285 lbs PERKINS 1104D-E44TAG2 EPA III Water 1800 rpm 269.1 cu. in. 4 line n° disp. Turbo-Intercooler 134 bhp 149 bhp 5.1 gal/h 6.8 gal/h 0.35 lb/hph Electronic STAMFORD UCI 274 C 110 (138) Kwe (kVA) 96 (120) Kwe (kVA) 54 (68) Kwe (kVA) H IP23 Electronic / 1.0% GSW160P 125 (156) kW (kVA) 142 (177) kW (kVA) 480/277 Volt 60 Hz 0.8 Cos 124 (155) kW (kVA) 140 (175) kW (kVA) 208/120 Volt 60 Hz 0.8 Cos 96 (96) kW (kVA) 106 (106) kW (kVA) 240/120 Volt 60 Hz 1 Cos 92 US Gallons 12.4 h 9.3 h 133.9" x 49.2" x 66.1" 4,573 lbs PERKINS 1106D-E66TAG2 EPA III Water 1800 rpm 402.7 cu. in. 6 line n° disp. Turbo-Intercooler 182 bhp 207 bhp 7.5 gal/h 10 gal/h 0.377 lb/hph Electronic STAMFORD UCI 274 E 155 (194) Kwe (kVA) 140 (175) Kwe (kVA) 77 (96) Kwe (kVA) H IP23 Electronic / 1.0% Note: Technical characteristics listed are not inclusive of any product customizations and the producer reserves the right to modify them for innovations without prior notice. www.milbankpowergen.com GSW200P 161 (201) kW (kVA) 178 (223) kW (kVA) 480/277 Volt 60 Hz 0.8 Cos 160 (200) kW (kVA) 175 (219) kW (kVA) 208/120 Volt 60 Hz 0.8 Cos 123 (123) kW (kVA) 136 (136) kW (kVA) 240/120 Volt 60 Hz 1 Cos 92 US Gallons 9.7 h 7.3 h 133.9" x 49.2" x 66.1" 4,880 lbs PERKINS 1106D-E66TAG4 EPA III Water 1800 rpm 402.7 cu. in. 6 line n° disp. Turbo-Intercooler 233 bhp 259 bhp 9.5 gal/h 12.7 gal/h 0.376 lb/hph Electronic STAMFORD UCI 274 G 203 (253) Kwe (kVA) 175 (219) Kwe (kVA) 99 (123) Kwe (kVA) H IP23 Electronic / 1.0% Product specifications Industrial Generators 208V (3 Phase) 480V (3 Phase) GRW Series | 15kW - 50kW Yanmar Series 240V (1 Phase) 28 Model Number PRIME POWER PRP EMER POWER LTP Voltage Frequency Power factor PRIME POWER PRP EMER POWER LTP Voltage Frequency Power factor PRIME POWER PRP EMER POWER LTP Voltage Frequency Power factor Tank capacity Autonomy (III) (75% PRP) Autonomy (III) (100% PRP) Dimensions (LxWxH) Weight (dry) DIESEL ENGINE Exhaust emissions Cooling system Speed Displacement Cylinders and disposition Aspiration Engine power PRP Engine power LTP Fuel cons (III) (75% load PRP) Fuel cons. (III) (100% load PRP) Specific consumption PRP Engine governor (standard) SYNCH. ALTERNATOR Power at 27ºC (480V) Power at 27ºC (208V) Power at 27ºC (240V) Insulation class Mechanical protection Voltage regulation GRW15Y 12 (12) kW (kVA) 14 (14) kW (kVA) 240/120 Volt 60 Hz 1 Cos 53 US Gallons 61.0 h 46.0 h 74.8" x 35.7" x 53.5" 1,993 lbs Yanmar 3TNV88 EPA IV Water 1800 rpm 100.2 cu. in. 3 line n° disp. Natural 22 bhp 24 bhp 0.9 gal/h 1.2 gal/h 0.397 lb/hph Mechanical STAMFORD BCI164C Dedicated 14 (14) Kwe (kVA) H IP23 Electronic / 1.5% GRW25Y 18 (23) kW (kVA) 20 (25) kW (kVA) 480/277 Volt 60 Hz 0.8 Cos 18 (23) kW (kVA) 20 (25) kW (kVA) 208/120 Volt 60 Hz 0.8 Cos 18 (18) kW (kVA) 20 (20) kW (kVA) 240/120 Volt 60 Hz 1 Cos 53 US Gallons 42.0 h 32.0 h 74.8" x 35.7" x 53.5" 2,174 lbs Yanmar 4TNV88 EPA IV Water 1800 rpm 133.6 cu. in. 4 line n° disp. Natural 29 bhp 32 bhp 1.2 gal/h 1.7 gal/h 0.397 lb/hph Mechanical STAMFORD BCI184F 30 (38) Kwe (kVA) 27 (34) Kwe (kVA) 15 (19) Kwe (kVA) H IP23 Electronic / 1.5% GRW35Y 31 (39) kW (kVA) 32 (40) kW (kVA) 480/277 Volt 60 Hz 0.8 Cos 29 (36) kW (kVA) 30 (37) kW (kVA) 208/120 Volt 60 Hz 0.8 Cos 20 (20) kW (kVA) 22 (22) kW (kVA) 240/120 Volt 60 Hz 1 Cos 95 US Gallons 54.0 h 40.0 h 82.7" x 38.8" x 62.4" 2,286 lbs Yanmar 4TNV98 EPA IV Water 1800 rpm 202.5 cu. in. 4 line n° disp. Natural 55 bhp 60 bhp 2.2 gal/h 2.9 gal/h 0.363 lb/hph Mechanical STAMFORD BCI184G 31 (39) Kwe (kVA) 29 (36) Kwe (kVA) 16 (20) Kwe (kVA) H IP23 Electronic / 1.5% GRW50Y 42 (52) kW (kVA) 42 (53) kW (kVA) 480/277 Volt 60 Hz 0.8 Cos 39 (49) kW (kVA) 40 (51) kW (kVA) 208/120 Volt 60 Hz 0.8 Cos 27 (27) kW (kVA) 30 (30) kW (kVA) 240/120 Volt 60 Hz 1 Cos 95 US Gallons 38.0 h 28.0 h 82.7" x 38.8" x 62.4" 2,438 lbs Yanmar 4TNV98T EPA IV Water 1800 rpm 202.5 cu. in. 4 line n° disp. Turbo 67 bhp 74 bhp 2.8 gal/h 3.8 gal/h 0.386 lb/hph Mechanical STAMFORD BCI184J 42 (52) Kwe (kVA) 39 (49) Kwe (kVA) 22 (27) Kwe (kVA) H IP23 Electronic / 1.5% Note: Technical characteristics listed are not inclusive of any product customizations and the producer reserves the right to modify them for innovations without prior notice. www.milbankpowergen.com PRODUCT SPECIFICATIONS 29 Industrial Generators 240V (1 Phase) 208V (3 Phase) 480V (3 Phase) GRW Series | 70kW - 200kW Perkins Series Model Number PRIME POWER PRP EMER POWER LTP Voltage Frequency Power factor PRIME POWER PRP EMER POWER LTP Voltage Frequency Power factor PRIME POWER PRP EMER POWER LTP Voltage Frequency Power factor Tank capacity Autonomy (III) (75% PRP) Autonomy (III) (100% PRP) Dimensions (LxWxH) Weight (dry) DIESEL ENGINE Exhaust emissions Cooling system Speed Displacement Cylinders and disposition Aspiration Engine power PRP Engine power LTP Fuel cons (III) (75% load PRP) Fuel cons (III) (100% load PRP) Specific consumption PRP Engine governor (standard) SYNCH. ALTERNATOR Power at 27ºC (480V) Power at 27ºC (208V) Power at 27ºC (240V) Insulation Mechanical protection Voltage regulation GRW70P 58 (73) kW (kVA) 64 (80) kW (kVA) 480/277 Volt 60 Hz 0.8 Cos 56 (70) kW (kVA) 58 (73) kW (kVA) 208/120 Volt 60 Hz 0.8 Cos 45 (45) kW (kVA) 50 (50) kW (kVA) 240/120 Volt 60 Hz 1 Cos 128 US Gallons 36.0 h 27.0 h 110.2" x 48.1" x 70.4" 3,977 lbs Perkins 1104D-E44TG EPA III Water 1800 rpm 269.1 cu. in. 4 line n° disp. Turbo 87 bhp 97 bhp 3.6 gal/h 4.8 gal/h 0.383 lb/hph Mechanical STAMFORD UCI 224 E 79 (99) Kwe (kVA) 71 (89) Kwe (kVA) 45 (56) Kwe (kVA) H IP23 Electronic / 1.5% GRW90P 74 (93) kW (kVA) 82 (103) kW (kVA) 480/277 Volt 60 Hz 0.8 Cos 74 (92) kW (kVA) 82 (102) kW (kVA) 208/120 Volt 60 Hz 0.8 Cos 68 (68) kW (kVA) 74 (74) kW (kVA) 240/120 Volt 60 Hz 1 Cos 128 US Gallons 30.0 h 22.0 h 110.2" x 48.1" x 70.4" 4,167 lbs Perkins 1104D-E44TAG1 EPA III Water 1800 rpm 269.1 cu. in. 4 line n° disp. Turbo-Intercooler 110 bhp 122 bhp 4.3 gal/h 5.8 gal/h 0.363 lb/hph Electronic STAMFORD UCI 274 C 106 (133) Kwe (kVA) 93 (116) Kwe (kVA) 54 (68) Kwe (kVA) H IP23 Electronic / 1.5% GRW120P 91 (114) kW (kVA) 100 (125) kW (kVA) 480/277 Volt 60 Hz 0.8 Cos 90 (113) kW (kVA) 96 (120) kW (kVA) 208/120 Volt 60 Hz 0.8 Cos 68 (68) kW (kVA) 74 (74) kW (kVA) 240/120 Volt 60 Hz 1 Cos 128 US Gallons 25.0 h 19.0 h 110.2" x 48.1" x 70.4" 4,167 lbs Perkins 1104D-E44TAG2 EPA III Water 1800 rpm 269.1 cu. in. 4 line n° disp. Turbo-Intercooler 134 bhp 149 bhp 5.1 gal/h 6.8 gal/h 0.350 lb/hph Electronic STAMFORD UCI 274 C 124 (155) Kwe (kVA) 110 (138) Kwe (kVA) 63 (79) Kwe (kVA) H IP23 Electronic / 1.5% GRW160P 125 (156) kW (kVA) 142 (177) kW (kVA) 480/277 Volt 60 Hz 0.8 Cos 124 (155) kW (kVA) 140 (175) kW (kVA) 208/120 Volt 60 Hz 0.8 Cos 96 (96) kW (kVA) 106 (106) kW (kVA) 240/120 Volt 60 Hz 1 Cos 260 US Gallons 37.0 h 27.0 h 143.7" x 51.6" x 76.2" 6,290 lbs Perkins 1106D-E66TAG2 EPA III Water 1800 rpm 402.7 cu. in. 6 line n° disp. Turbo-Intercooler 182 bhp 207 bhp 7.5 gal/h 10.0 gal/h 0.377 lb/hph Electronic STAMFORD UCI 274 E 150 (188) Kwe (kVA) 136 (170) Kwe (kVA) 77 (96) Kwe (kVA) H IP23 Electronic / 1.5% Note: Technical characteristics listed are not inclusive of any product customizations and the producer reserves the right to modify them for innovations without prior notice. www.milbankpowergen.com GRW200P 161 (201) kW (kVA) 178 (223) kW (kVA) 480/277 Volt 60 Hz 0.8 Cos 160 (200) kW (kVA) 175 (219) kW (kVA) 208/120 Volt 60 Hz 0.8 Cos 123 (123) kW (kVA) 136 (136) kW (kVA) 240/120 Volt 60 Hz 1 Cos 260 US Gallons 27.0 h 20.0 h 143.7" x 51.6" x 76.2" 6,585 lbs Perkins 1106D-E66TAG4 EPA III Water 1800 rpm 402.7 cu. in. 6 line n° disp. Turbo-Intercooler 233 bhp 259 bhp 9.5 gal/h 12.7 gal/h 0.376 lb/hph Electronic STAMFORD UCI 274 G 220 (275) Kwe (kVA) 200 (250) Kwe (kVA) 114 (143) Kwe (kVA) H IP23 Electronic / 1.5% 30 Product specifications Vx Series Portables Model Number Starting Rated Watts PM0103007 PMC103007 PC0103007 PM0101207 PC0101207 PM0105007 PMC105007 PC0105007 PM0106507 PMC106507 PC0106507 Manual Manual Manual Electric 1200 Watts 3000 Watts 5000 Watts 6500 Watts Surge Watts 1400 Watts 3750 Watts 6250 Watts 8125 Watts Engine Series Powermate OHV Powermate OHV Powermate OHV Powermate OHV Engine Displacement 98cc 212cc 389cc 420cc Oil Alert No Yes Yes Yes USDA-Qualified Spark Arrester/Muffler Yes Yes Yes Yes Low Oil Shutdown Yes Yes Yes Yes Fuel Tank Capacity 1.5 Gallon 4.0 Gallon 6.5 Gallon 6.5 Gallon Yes Yes Yes Yes Run Time @ ⁄2 Load 12 Hours 12 Hours 11 Hours 9 Hours Dimensions L x W x H (inches) 19 x 14.25 x 17 24 x 18 x 18 28 x 22 x 22 28 x 22 x 22 Fuel Gauge 1 Dry Weight Wheel Kit Outlets 64 lbs 99 lbs 164 lbs 179 lbs No Included - 8" Included - 10" Included - 10" (1) 120V 5-15R Duplex, (1) 12V DC (2) 120V 5-20R (2) 120V 5-20R (2) 120V 5-20R Duplex, (1) Duplex, (1) Duplex, (1) 120/240V L14-30R, 120/240V L14-30R, 120/240V L14-30R, (1) 12V DC,. (1) 12V DC (1) 12V DC (1) 120V L5-30R Standard and Elite Series Briggs & Stratton Portable Generators Model Number MGP5502 MGP7000 (Elite) MGP8002 (Elite) 5500W Rated / 6875W Surge 7000W Rated / 8750 Surge 8000W Rated / 10000W Surge Engine Series 1650 Series™ OHV 2100 Series™ OHV 2100 Series™ OHV Gross Torque 16.50 ft-lbs 21.00 ft-lbs 21.00 ft-lbs Rated/Surge Watts Engine Displacement 342cc 420cc 420cc Fuel Tank Capacity 7 Gallons 7 Gallons 7 Gallons Run Time @ 1⁄2 Load 10 Hours 9 Hours 9 Hours Alternator Power Surge™ Power Surge™ Power Surge™ Starting Recoil Recoil/Electric Recoil/Electric Muffler Super Lo-Tone™ Super Lo-Tone™ Super Lo-Tone™ Wheel Kit 10 in. 12 in. 12 in. Warranty 2-Year Limited 3-Year Limited 3-Year Limited (4) 120V-20A,. (1) 120/240V-30A locking (4) 120V-20A,. (1) 120/240V-30A locking (4) 120V-20A,. (1) 120/240V-30A locking No Yes Yes Outlets Float Charge Jack www.milbankpowergen.com PRODUCT SPECIFICATIONS 31 Pramac S Series Portables Model Number Rated Watts Surge Watts Engine Fuel Tank Capacity Dimensions (inches) Dry Weight S3100 S4000 S6000 S7200 S14000 2600 Watts 3800 Watts 5300 Watts 6100 Watts 11700 Watts 3100 Watts 4000 Watts 6000 Watts 7200 Watts 14000 Watts Honda GX160 Honda GX240 Honda GX340 Honda GX390 Honda GX630 2.9 Gallons 7 Gallons 8 Gallons 8 Gallons 8 Gallons 22.8 x 16.5 x 18.0 29.1 x 22.3 x 25.6 31.4 x 22.3 x 25.6 31.4 x 22.3 x 26.3 38.9 x 22.4 x 32 88 lbs 160 lbs 188 lbs 199 lbs 316 lbs Pramac Powermate Portables Model Number PM0435006 PM0675700 PM0676800 PM0676801 PM0497000.04 Rated Watts 5000 Watts 5700 Watts 6800 Watts 6800 Watts Surge Watts 6250 Watts 7125 Watts 8500 Watts 8500 Watts Engine Series Subaru EX90 Yamaha MZ 300 Yamaha MZ 360 287cc 301cc 357cc Engine Displacement Oil Alert PM0418000 PM0601250 7000 Watts 8000 Watts 12500 Watts 8750 Watts 10000 Watts 15625 Watts Yamaha MZ 360 Honda GX390 Kohler PS-44550 Subaru EH65 357cc 389cc 426cc 653cc Yes No 76.1 dBA 78 dBA Yes USDA-Qualified Spark Arrester/Muffler Yes No Noise Level @ 22 ft. 72.4 dBA 77 dBA Fuel Tank Capacity 5.0 Gallon 6.5 Gallon Fuel Gauge 77.2 dBA 77.2 dBA 76.3 dBA 8 Gallon No Yes Run Time @ ⁄2 Load 9.2 Hours 10 Hours 11.6 Hours 11.4 Hours 10.54 Hours 9.95 Hours 6 Hours Dimensions L x W x H (inches) 29 x 21 x 25 29 x 21 x 26 31 x 21 x 24 31 x 21 x 24 31 x 21 x 24 31 x 21 x 30 39 x 22 x 30 167 lbs 182 lbs 210 lbs 185 lbs 199 lbs 249 lbs 336 lbs (2) 120V 5-20R Duplex,. (1) 120/240V (1) 120V L5-30R, (1) 120/240V 14-50R, (2) 120V 5-20R GFCI Duplex 1 Dry Weight Outlets (2) 120V 5-20R Duplex, (1) 120/240V L14-20R DeWALT Portable Generators Model Number DG7000B Important Warranty Information 6300 Watts 7000 Watts DeWALT portable generators come with a 2-year engine warranty and a 2-year product warranty. 4180 Watts 5950 Watts 6550 Watts Brushless Brushless Brushless Brushless DG3000 DG3000C (CARB) DG4400B DG4400BC (CARB) DG6300B Max Watts 3000 Watts 4400 Watts Max/Rated Current (120/240V) 2920 Watts Alternator Type Fuel Tank Capacity 3.3 Gallons 4.8 Gallons 4.8 Gallons 4.8 Gallons Run Time @ 50% Output 8 Hours 8 Hours 8 Hours 8 Hours Noise Level @ 21 ft. 74 dBA 72 dBA 72 dBA 72 dBA Dimensions (inches) 23.6 x 19.3 x 20.5 24 x 19 x 21 28 x 22 x 22 28 x 22 x 22 118 lbs 223 lbs 246 lbs 261 lbs Dry Weight www.milbankpowergen.com These units are also eligible for 2-year free maintenance on spark plugs, fuel filter, air filter and oil. Log onto DeWALT.com/2YearGeneratorMaintenance to register your new generator to be eligible for the free maintenance offer. 32 more information If you should have any questions or run into maintenance issues with any Milbank Home Standby Generator product, we recommend you first contact the contractor who performed the original installation. First-hand knowledge of your original system installation makes them best equipped to field questions and perform any necessary maintenance. Oftentimes installers will also offer you special maintenance agreeements once the original system is installed, making any potential mechanical problems less worrisome. www.milbankpowergen.com MILBANK ONESERT EMERGENCY RESPONSE 33 Milbank OneSERT Your one-stop emergency response team The next natural disaster affecting your area is not a matter of IF, it’s a matter of WHEN. And when that time comes, you need immediate world-class service. That’s why Milbank Manufacturing offers OneSERT, your One-Stop Emergency Response Team to get you the product you need, when you need it. During the unprecedented winter storms in early 2011, Milbank was able to react quickly and ship out a truckload of portable generators to an electrical distributor in the Midwest in less than an hour. A single call to 800-227-5564 sets the OneSERT team in motion: • After-hours call support 24 hours per day, 365 days per year • During Milbank normal business hours 8am-5pm CST - call 877-483-5314 • Single point of contact to coordinate all aspects of the emergency • Expedited product availability • Optional solutions on product applications • Fast, reliable service When a natural disaster strikes your area, put the country’s leading manufacturer of meter sockets and related products on your team. Call Milbank’s OneSERT emergency line at 800-227-5564 or visit www.OneSERT.com. Note: this program is available only to our current electrical distributors. www.OneSERT.com 800-227-5564 www.milbankpowergen.com Home Standby Generator system 34 frequently asked questions What is the difference between portable generators and automatic home standby generators? The differences have to do with the steps needed to have emergency power flowing into your house in the event of a power outage. Portable systems are wheeled units that require you to roll the generator outside, start it up, and hook it up to a power inlet box. From there you must go to the transfer switch panel installed near your circuit breakers and switch the power coming into your house from the main line to the generator running outside. After the power from your local utility is restored, you are required to reverse the setup process. One of the clear advantages with an automatic home generator system is that the unit turns itself on and off automatically without you ever having to leave the safety of your home. Our automatic home generator systems also exercise themselves once a week. You can even set the time when the unit will perform this diagnostics check. The generator will then be ready to run whenever needed. Also, most portable generators have a high total harmonic distortion (voltage fluctutation) which is not recommended for sensitive electronics. Our home standby generators run at 5% THD or less, assuring clean power. How does the home generator system work? At the point of loss of utility power, the system will wait approximately 6 seconds to start (this is to verify that the power is going to stay out). After it has started it will go through a warm up period of 20 seconds. After this time the transfer switch will change over to generator power. The house will remain under generator power for a minimum of five minutes, even if the utility power comes back on. After utility has come back on, and the generator has powered up the house for at least five minutes, the transfer switch will go back to utility power after 10 seconds. The generator will then run one minute to cool down before turning itself off. What size standby generator do I need to run the electric items in my house during a power outage? Most average homes of 1,200 to 3,000 sq. ft. can run critical items in the home by using a 5,0007,000 watt generator. The most common items that need emergency power during a blackout would be the furnace blower motor, refrigerator, freezer, lights, TV, sump pump, and water pumps. Larger home generator systems in the 10-15KW range will quietly supply as much as 18,000 watts of starting power to your home automatically, giving your family the power, freedom and comfort of their usual lifestyle uninterrupted by power failure. The 12-20kW generators allow you to supply power to both essential items and up to six high wattage appliances including two central air units for the ultimate in comfort and control. What is a transfer switch? Can I run a computer or other sensitive electronic equipment off the generator during a power outage? How do I know what size transfer switch I need? Yes. The power coming from your generator is just as safe as what you normally have coming out of the wall socket. The spikes or surges that accompany power generation (also known as “harmonic distortion”) are just a normal aspect of electricity. However, when considering sensitive or expensive electronic equipment running off a wall outlet, you should use a good surge protector to guard against small influxes of power. Does motor starting require a different wattage? Yes. Induction motors require larger amounts of amperage for initial start-up than when they are running. Some appliances and tools, such as your refrigerator/freezer, furnace fan, air conditioner, electric chain saw, weed trimmer, etc. will require more watts than normal running wattage for motor starting. This must be considered when sizing a generator to meet your needs. What does a home generator system typically cost? When you choose the safety, reliability and automatic operation of a home generator system, there are several items that contribute to the total cost: the cost of the system itself, a transfer switch, and installation charges. Optional maintenance contracts can also add to the cost if you choose one. Costs may vary depending on the size of the unit, transfer switch used, location of installation, and permits required for installation. Check with your local sales representative. Can I run my central air conditioner on the home generator system? Yes. We have designed a transfer switch that will monitor loads on the generator, under emergency power, allowing you to run a central air unit at a 4-ton rating or less on our 12kW and 15kW generator systems. They are available in 100 or 200 amp sizes. We also offer a load control center to aid in running air conditioning systems. A transfer switch is a device that is fed by both utility and generator power. It isolates the two types of power from each other so a back feed does not occur. National Electrical Code requires a device like this if two types of power are going to feed the house. There are many factors that will determine the size transfer switch needed (size of utility service, appliances needed to run, size of generator, etc). The transfer switches available vary from 100 and 200 amps. Call 877-483-5314 or inquire with your local sales representative for assistance. The 100 and 200 amp transfer switches are for whole house power and feed the entire distribution panel. What is the Load Control Center and how can it benefit me? With our power management transfer switch, there must be room on the generator for a central air unit to run. The LCC isolates six circuits from your main distribution panel to allow the air conditioner to start when it wants. Basically, the LCC makes room on the generator. These would be circuits that you would not mind being turned off for a short period of time while the A/C runs. You can hook these circuits up in priority, 1 is the highest priority and 6 is the lowest. Discuss with a contractor how you want each item hooked up. How do I purchase a generator? Who do I contact? If you are interested in learning more about our products or are looking for information on how to purchase, please call 877-483-5314. Can I install the unit myself or does someone else need to? It is recommended that you have your home generator system (generator and transfer switch) installed by a licensed contractor. Failure to do so could be dangerous for both family members as well as outside repair workers trying to fix downed power lines. In addition, professional installation is required to maintain the warranty. They would also make sure that all the necessary permits are pulled to verify it will pass code and safety inspection. Most Milbank Home Generator Systems dealers are capable of not only performing the necessary installation, but can also offer maintenance agreements that ensure the generator is being serviced on a regular basis. Check with your local sales representative for more information. www.milbankpowergen.com Home Standby Generator system frequently asked questions 35 What happens in a typical installation? A basic installation includes: • Delivery of the system to dealer. Additional charges for drop ship to consumer. • Installation of the 50, 100 or 200 amp transfer . switch hardwired into your home or . business. • The transfer switch is installed within two feet . of the main distribution panel and 30 feet of the . generator inlet box. • Final start up inspection of system and . completion of start up form. • Cleanup of installation debris after installation is . completed. • Consumer is responsible for making . arrangements to provide all necessary gas . service and connections. What does Automatic Voltage Regulation (AVR) do for me? The 7kW home standby system features AVR. AVR maintains a more steady voltage than something that is not regulated. This is especially important for running sensitive electronics such as computers, microwaves, and televisions. What is the warranty? The warranties will vary depending upon the unit that is purchased. Entry level systems will carry a 2-year warranty; while more advanced systems carry a 3-year/1,500 hour warranty. There is also a fourth year power train warranty with our more advanced units. To validate your warranty, simply return the postage paid installation checklist. Do I need to start the generator frequently when it is not being used? One of the advantages of the 7, 10, 12, and 15kW automatic home generator systems is that they are designed to run once a week for 20 minutes. All you have to do is program when you want this task to be performed and it will start up automatically. During this time it will not only lubricate the engine, but it will also run a diagnostics check. If there are any problems with this process, an LED display located inside the front access panel or your inhome remote performance monitor will alert you to a problem if one exists. www.milbankpowergen.com How long will a unit run before I have to let it cool down or refill it with fuel? Another advantage of our home generator systems is that they run on liquid propane or natural gas, so they don’t need to be refueled as often, if at all. Additionally, rest periods to allow cooling are not necessary. All Milbank home generator systems are air- or liquid-cooled and do not require you to turn them off after extended run times. However, you will need to turn off the unit before refueling (if running on liquid propane) or when checking the oil levels which should be done on a regular basis during and after extended use (refer to your owner’s guide for instructions). Do I have to worry about “backfeed” if the generator is running when the power comes back on? No. All of our transfer switches are designed to keep generator backfeed from occurring. When the contractor installs the transfer switch, it will be connected directly to the utility power. A control board will be able to sense when the utility power has returned to transfer back to utility (it is programmed so the generator powers up the house for a minimum of five minutes). Everything is programmed so that one source of power is broken before another source of power is made. How often do I have to change the oil? The engine maintenance manual recommends 50hour intervals between oil changes and 100-hour intervals for the oil filter. We do require that 5W30 fully synthetic oil be used when replacing the oil. This will enable the engine to stabilize quicker (it has 20 seconds to do this). All home generator systems are shipped fully lubricated and the engines broken in; no break-in of the engine needs to be performed. Who do I call if I have any questions or maintenance issues? We recommend that you first contact the person or contractor who performed the original installation. First-hand knowledge of your original system installation makes them best equipped to field questions and perform any needed maintenance. Oftentimes installers will also offer you special maintenance agreements once the original system is installed, making any potential mechanical problems less worrisome. You can also call Milbank at 877-483-5314 if a problem requires additional help. Can I vent exhaust out of an enclosed area? No. Carbon monoxide gases produced by the engine could be deadly. Milbank home generator systems are designed to be run outside only where there is plenty of ventilation. Never run these units inside a home or enclosed area. All Milbank home generator systems are permanently installed outside your home. Can I run the generator inside my home? No! A generator has an internal combustion engine and uses gas and oil. The exhaust from running a generator contains lethal carbon monoxide. Therefore, this unit should always be placed in a well-ventilated area and never run or be installed in an enclosed area. How can I get more information on Milbank Home Generator Systems? You can request information and support through our web site at www.milbankpowergen.com or by calling 877-483-5314. Milbank PowerGen™ 4801 Deramus Avenue | Kansas City, MO 64120 www.milbankpowergen.com | 877.483.5314 GenCat 5/11 (3K)