Download Sears Kenmore 758.144105 Owner`s manual
Transcript
f READ AND SAVE THESE mNSTRUCTmONS , F__AIRtS OWner'S Stock No. 42-14410 Mode_ No. 758.144105 QUIETCOMFORT WHOLE HOUSE HUMIDIFIER FOR YOUR READ ALL mNSTRUCTIONS CAREFULLY Sears, Part No. SP6519 Roebuck 10 Gallon Output • Operating mnstructions • Parts List and Co., Hoffman Estates, IL 60179 U.S.A. Printed in Canada FULL ONE YEAR WARRANTY ON HUMmDmFIER _f within one (1) year from the date of purchase, this humidifier falls due to a defect in material or workmanship, Sears will repair it, free of charge. If within two (2) years from the date of purchase, the motor fails due to defect in materia_ or workmanship, Sears witl repair it free of charge. This warranty service is available by simply returning the humidifier to the nearest Sears Service Center/Department throughout the United States. This warranty applies only while this product is used in the United States. This warranty gives you specific _egal rights, and you may also have other rights which vary from state to state. Sears Roebuck and Co. D1817 Hoffman Estates IL 60179 GENERAL SAFETY iNSTRUCTiONS Safety Signal Words 5. DANGER: means if the safety not followed, someone will injured or killed. information is be seriously 6. 7. injured or killed. information is be seriously the humidifier Keep the humidifier the used by or while any part or damaged in any manner. the risk of electrical hazard to humidifier, the risk of accidental electrical shock, do not touch the cord or controls with wet hands. the the warning label shown below. iWARNmNG: To reduce risk of fire, tric shock, or injury always |beforef ng, servcngorceanng. clean. elec- unplug Table of Contents Warranty Information .................................. General Safety instructions ........................ To Save A Service Call ............................... Know Your Humidifier ................................. 3 4 4 5 Electrical 5 Hook=Up ...................................... To Save a Service Check the following if your not operating. 1, Is power cord attached 2, Is there electrical humidifier Water 2 2 2 Humidifier Operations ................................ Assembly .................................................... Location Instructions .................................. or do not tilt, jolt or tip mov= ing it, before cleaning, or whenever humidifier is not in service. 4. use your humidifier 1O.To reduce 11.Note before when inside unplug humidifier, when the base is empty or when the humidifier is not in use. stoves or heaters. unplug Never objects humidifier while unit is running. 9. To reduce the risk of damage to humidifier, reduce the risk of fire hazard, never put the electric cord under rugs, near heat registers, radiators, to be used as a toy. Close damage Keep the electric cord out of traffic areas. To 3. Always Do not allow is missing 8. To reduce 1. To reduce the risk of fire or shock hazard, plug humidifier directly into a !20V, A.C. electrical outlet. Do not use extension cords. 2. foreign attention is necessary near children. WARNING: means if the safety information is not followed, someone could be seriously CAUTION: means if the safety not followed, someone may injured or killed. Do not put humidifier. Fill .................................................. 6-7 Operating Humidifier Controls ................... 7 Using Your Humidifier ................................. 8 Operating Tips for Best Performance ......... 8 Replacement and Care of Filters ........... 9=10 Cleaning Your Humidifier ..................... 11=12 Troubleshooting ....................................... 13 Repair Parts ......................................... 14=15 CM/ is 3, Is airflow control in operating position? 4. Is humidity control set high enough? 5. Is the humdifier sitting on a level sur- to outlet? power to outlet? face? 2 Know Your Humidifier Fan Assembly Humidity . .... Bottle HandBe Centre[ Bottle Base /i Filter: Replacement 42°14906 42-14410 Description Gallon Output/24 Capacity of Bottle Capacity of Base hrs Sq. Ft. Coverage Fan Speeds Replacement Power Light Fil! Light Auto Humidistat Auto Shut Off Filter 10 1,9 Gallons 2,0 Gallons 2100 3 42-14906 Yes Yes Yes Controls CUL Listed Yes Rotary Yes Volts Hertz 120 A,C. 6O Amps Watts 0,80 Based on an area with average and an 8 foot ceiling height. insulation 8O No. Humidifier Your new Sears Operations humidifier is designed satisfy home humidity requirements through the principle of evaporation water in the air. through is added to the humidifier, filter begins to soak up the water ings Humidified air is then released of After water become minutes. to and will saturated in approximately 30 Air drawn in through the open- in the lower housing the filter by means passes through of a circulation the top the fan. As Dry air enters through the mouvers in the housing air passes through the filter, moisture is absorbed into the air and then released in the form will enter of vapor. No water the home. the air takes place droplets Al! evaporation into in the humidifier, which means that the residue left by evaporating water is not passed into the home, but remains in the filter. This natural process eliminate the chance humidified output CAUTmON: of evaporation helps of white dust in the air. Use onJy 42°14900 EPA Registered Bacteriostat availabJe from SEARS Retail store. Under no circumstances should you use water treatment products designed for Roto belt or Ultrasonic humidifiers. CAUTmON: To reduce the injury, or damage to humidifier, fire risk of use only cleaners specifically recommended for humidifiers. Never use fJammable, combustible or poisonous materials to clean your humidifier. To reduce the risk of scaJds and damage to humidifier, water in humidifier. never put hot Assembly Your new Sears completely Kenmore assembled humidifier for you to use. is Follow manual the instructions for proper of this owner's usage. Location Instructions WARNBNG: not For your use humidifier _damaged or mss Step 1 Place humidifier own safety, -- do The humidifier should be positioned with Step 2 the back (cord exit side) and left side, at if any parts are rig, least 2 inches away from the wall. Air needs to enter through all of the louvers on a flat level surface an area of house where in the housing is humidifier most humidity assembly to operate in in order for the at peak efficiency. needed, or one which would likely result in moist air being circulated throughout the house such as near a cold air return. Placing the unit level is very important. Special attention should be given to unit's level if the humidifier is located carpeting. Moist air (humidity) into the whole produced house, on wi!l disperse but the area closest to the unit will have the highest humidity. At _east 2" from wal_ If the unit is positioned close to a window, condensation may form on the window pane. If this is not appropriate the unit should be repositioned in another NOTE: Due to release of cool, moist it is best to direct location. air from humidifier, air away from ters. home thermostat and hot air regisIt is best to position humidifier next to an inside wall. Hot air registers and cold air from outside walls can affect the efficiencies placed of the controls. where warm ister blows directly Unit should air from not be a hot air reg- on unit. Electrical Hook-Up Locate nearest 120V A.C. wal! socket in will fit in a polarized outlet only one way. If the plug does not fit fully in the outlet, the location desired, preferably on inside wall. With the humidifier in the desired location, route the electrical reverse cord safely so no one will trip or upset the humidifier. outlet. Plug in the electrical way. WARNING: or shock cord. To reduce hazard, the risk humidifier of fire should be plugged directly into a 120V A.C. outlet, Do not use extension cords. To reduce the risk of electrical humidifier has a polarized blade is wider shock, this plug (one than the other). This plug plug. a qualified 1 1 If it still does electrician Do not change not fit, contact to install the proper the plug in any Water Fill WARNING: To reduce shock, always before cleaning WARNBNG: of humidifier or servicing. To reduce or shock hazard, water into control mfcontrols the risk unplug the risk of fire do not pour or spH[ or motor area. get wet, Bet them dry pletely and have unit checked authorized service personnel plugging com- by before in. This humidifier is designed for use with the water bottle located to the right of the upper grill. The water bottle holds 1.9 gallons of water. The humidifier should be positioned where To fill the whole the bottle it will be operating. house handle humidifier, grasp at the top of the bottle and lift it straight up and away from humidifier base. Take care not to bump or damage spring tom of bottle. NOTE: valve If it is desired bactedostat, The bottle will hold follow assembly to use approved directions of the whole 1.9 gallons on bot- correctly. house humidifier of water. The water bottle is designed with an 'E-ZFill Side-Cap". Remove the 'E-Z-Fill SideCap" on the side twisting of the water Spring VaUve Assembly by counterclockwise. Place the opening under bottle a water of the water faucet bottle and fill. If desired, add Sears liquid bacteriostat (stock number 42_14900) to help control the build up of bacteria and algae. Do not use solid water treatments. Solid debris could make the lower valve leak. Install the ' E-Z°Fill clockwise. Check Hand Side-Cap" tighten for possible by twisting only. leaks by perform° ing the following: 1. Grasp upright bottle 4. Listen for air bubbles. around handle and hold the bottle over a sink. valve the "E-Z-Fill 5. If you hear air bubbles retighten 3. Release Wipe repeat and plunger. 2. Press up on valve plunger for about one second to let out a little water. the plunger. Look for leaks Side-Cap" or see leaks, the ' EoZ-Fill Side-Cap" steps and 1o4. off excess water from the bottle. Position thewaterbottlebackintothe humidifier basetotherightofthegrille. The"E-Z-Fill Side-Cap" mustbefacing outward. Whenpositioned properly, the plunger willopenandwaterwillflowinto thebase.Thebasewillholdtheentire contents ofthewaterbottle. Allowupto oneminute forthewatertoflowintothe base.Oncethebottleisempty, remove it andrefillitasmentioned earlier.Return it totherightsideofthegrille.Thehumidifierisnowfilledtocapacity. Operating The operating Quiet Comfort located Humidifier Familiarize Controls controls of your Kenmore whole house humidifier are towards the front of the humidifier. yourself Speed Control This humidifier tro! switch. with the controls. manual. the Controls water the unit is plugged on, the red power in and turned light will come require off ( _ ) and humidity out- with the fan control the air flow speed, is evaporated on the more and released into the of depending as high an evaporation rate. Refill Light When the unit has a small amount of water left in it, the amber refill light will come on and the unit will automatically shut off. Control: the amount humidity fan con- on. It will stay on until the unit is turned or unplugged. Humidity speed - Medium air. Low speed (o) is the quietest and is also provided for conditions that may not Power Light Adjust The maximum put is obtained high ( _ ), The higher To Operate @ has a three (o) - Low, (;) ( ,,") - High). Reference the diagram of the control area for the correct nomenclature used in this When Thewaterbottlemaybefilledatanytime asnecessary duringoperation. Tobenefit fromlessfrequent fillingletthehumidifier exhaust boththewaterfromthebottle andbasebefore filling. Theunitisnowreadyforoperation. on your needs. The humidifier wil! turn on and off as required to maintain level of humidity selected. A medium setting controls rotation) there are times (half way between the is recommended, when low or high amount of humidity may be preferred. stant operation of humidifier, For conrotating the control allows all the way the maximum evaporated of humidity @ for to be into the air continuously. IMPORTANT: condensation or walls. clockwise amount Power Light Off Position but Water damage may result starts to form on windows Humidity be lowered forms. Control setting until condensation should no longer if Humidity \ Speed Control Control Refill Light Using Step Your Humidifier ! Step Be sure unit is full of water in. Step level Control to LOW Control ( " ). (see diagram below) to a medium is at the normal mended indoor humidity below shows approximate position ty percentages various NOTE: Humidifier should operate control on the recommended medium setting. If it does When ty is at a relatively high level. To test the unit under this condition, turn Humidity should begin to operate. After been tested, set Humidity medium or desired level. Allow 24 hours correspond of the Humidity Outdoor Indoor Temperature and unit the unit has Control for humidifier which settings levels. The figure relative humidi= to the Control. Recommended not, the humid!= al! the way to clockwise for that with humidity Control requirements setting or it is adjusting to the home conditions. The table below shows recom= 3 Set Humidity 4 If humidifier stops running and the amber Refill Light is not illuminated, the humidity 2 Set the Speed Step and plugged is: Relative Humidity -10°F 20% 0°F 25% 10°F 30% 20°F & above 35% to is: to adjust. MIN If humidity level in home is sufficient, humidifier will only operate Control set on maximum. IMPORTANT." condensation or walls. Humidity Water damage may result starts to form on windows Humidity be lowered forms. with the Control setting until condensation if should no longer Relative Operating 1. Position Tips for Best Performance the humidifier inside wal! at least 2. from Do not restrict airflow Use next to an 2 inches wall and away ters. exiting 3. from any heat 4. the regis= 5. from entering riostat (available store) to retard at your may cause odors to your health. cleaning or bacte= local Sears growth as instructed in that and may be harmful of Replace the evaporative wicking filter at least once per humidification season or more EPA approved bacteria Regular "Cleaning Your Humidifier" section this manual is recommended. the humidifier. 42-14900 Humidity ditions depending in your area. on water con- Replacement shock or injury from and Care of Filters moving parts, always unplug humidifierthe risk beforeof WARNBNG: To reduce removing or replacing any parts. CAUTION: growth To hemp retard and keep bacteria maximum effic[eno cy, the fimter should be replaced at [east once per season, or more often under hard water conditions. Use Sears recommended fitter 42-14906. replacement To replace the filter in your humidifier, follow the instructions below. Unplug humidifier. Before removing mend moving area where the filters, we recom- the humidifier floor coverings to an are not susceptible to water damage. kitchen or bath areas.) Remove the water Be sure not lower spring (i.e. bottle and set aside. to bump or damage the Grasp housing assembly securely and lift off valve. Grasp the housing assembly and lift straight up and away from the base and set aside. The filter is now accessible. 4. Take Fitter note of the filter position. Remove the filter and dispose of prop° erly. You may want to clean the base at this time. See the "Cleaning "four Humidifier" section of this manual. Base // Replacement Install a new filter and Care of Filters (42_14906) into the Base Uprights base, Coil the filter and position it between the uprights in the bottom of the base, The start and finish of the coil should be captured of the base ter should the base, Return at the centre (see diagram) be resting the housing and the fil- on the floor assembly \ Base of to the top of the base, Return the water bettie to the right of the housing assembly and reposition operating 7, (continued) the humidifier Position start Return bottRe to its position, The humidifier is now ready to be filled for operation. to right side of humidifier. 10 Cleaning WARNmNG: injury, Your Humidifier To reduce fire the or damage risk of Step 2 To Remove to humidifier, use only cJeanera specifically recommended for humidifiers. Never use flammable, combustible or poi- sonous materials to clean your humidifier. To reduce the risk of scalds and never put damage to humidifier, hot water in humidifier. Parts 1, Remove the water bottle and set aside. Be sure not to bump or dam= age the lower spring valve, 2_ Grasp the housing assembly and lift straight up and away from the base and set aside. The filter is now accessible. CAUTION: Local water purity varies from area to area and under certain conditions borne water bacteria impurities may promote growth of microorganisms reservoir of the humidifier. To retard bacteria cause odors and health, use only fitters. We also EPA approved and humidifier available Step and 3. air- the dispose or of properly. in the NOTE: There may be a little water still in the base. Carefully dump the water out or growth that may be harmful to your Sears Take note of the filter position. Remove the filter and set aside remove with a sponge. replacement recommend using bacteriostat, 42=14900 cleaner 42=14713, at your local Sears store. 1 To make cleaning easier, the humidifier base should be empty and completely dried lowing a. out, To accomplish Allow amber use the fo!- Unplug NOTE: Remove the humidifier Refill automatic humidifier b. this, method: to run until the light illuminates shutoff fan. has stopped water before and the the humidifier. plugged, fan coumd start WARNING: if humidifier is removed. after housing is not un° 1 11 excess cleaning. Cleaning Step End of Season Maintenance 1. Scale Fil! the humidifier base with one 8 oz. cup of undiluted solution 2. stay white vinegar. 20 minutes. Clean all interior brush. Dampen surfaces Rinse thoroughly water to remove solution. Disinfecting 1. out the warm and cleaning 4. Store in cool, 5. Install a new filter before next season Note: filter. before with water inside dry location. ' Bi-Weekly in clean humidifier begins. Maintenance" is if you do not plan for one week or more. stay for 20 minutes, every few surfaces normally Empty NOTE: carefully minutes. exposed Wet al! to water. base after 20 minutes. until bleach smell Position Rinse is gone. unit to dry out completely. The water cleaned bottle in the same Rinse thoroughly steps are complete. Step 4 Replacing Install should manner with clean be as the base. water after al! Parts a new filter (42=14906) filter previously set aside good condition into the base. or the if it is in Coil the Align housing assembly bottom with filter and position it between the uprights in the bottom of the base. The start and finish of the coil should be captured in the centre (see diagram) top of base of the base and the filter should resting on the floor of the base. Return the housing assembly be to the top of the base. Return the water bot= tie to the right of the housing assembly and reposition operating 3. away dry completely also recommended to run the humidifier swishing Allow 2. and throw storing. Do not store base or bottle. Base with water 1. Let humidifier Pour 1 gallon of water and 1 teaspoon chlorine bleach into the base. Let solution 2. scale Remove 3. with undi- with clean Follow "Bi-Weekiy Maintenance" instructions at end of humidification 2. with a soft a soft cloth Maintenance season, Let luted white vinegar and wipe base to remove scale. 3. (continued) 3 BFWeekty Removing 1. of Humidifier The humidifier filled the humidifier to its position. is now ready to be for operation. 12 start Troubleshooting Trouble Power Probable light not illuminated * Check 120 volt power source, control tion (See Unit will not run and Fill Light is not on. Red power Remedy * No Power • Speed Note: is on. Cause in off posi- page • Turn speed 7,) * Selected humidity level has been established, * Raise on and • Humidity control turned al! the way clockwise to "Constant On" position. humidistat setting • Turn humidity control counter clockwise until the fan turns oft. • Desired humidity established, not * Allow up to 24 hours of run time for unit to adjust. • Humidifier size for * Designed under requirements. to satisfy • Float is not free, Unit will not dry out • This is normal, * Free float from obstruction. * A small completely, amount remains • Air is entering the bottle. • Check of water in the base after the Refill to empty. an area up to 2100 sq, ft. Unit will not shut off, continues clock- light Unit will not cycle off. Bottle control wise. Light comes "E-Z-Fill on. Side-Cap" and lower spring assembly Check for leak in water bottle. Ensure gasket Side-Cap" Unit is not emptying use, during * Dirty filter. Change filter. for "E-ZoFill is in place. to a fresh new Lower spring assembly on bottle damaged or missing Check orientation of bottle, Reposition so that lower post in bottom spring valve assembly of base, is depressed by post in bottom of base. CAUTION: Use only Retail store. Use of other water 42-14900 treatment Under no circumstances Roto belt or Ultrasonic EPA Registered products should you humidifiers. Bacteriostat may damage use water 13 available the filter treatment from Sears component. products designed for Repair Parts , Parts List for Sears Humidifier Mode_ No. 758.144105 14 Repair Parts Parts AN_ays Key No i order Part by part No. number o Not by key number Description Housing, Upper • Assembly, Control Knob 1 830487 2 829822 3 830494 4 829821 5 829819 6 823728 Switch, Micro 7 830489 8 42°14906 Housing, Lower t Filter • Blade, Fan • Motor 9 829815 10 830496 11 829816 Screw, Pan Hd. Ty. AB #6 x 1/2 SS Support, Filter Float 12 830484 Base 13 829808 Foot, Rubber 14 830537 Bottle, Includes Key # 15 15 824690-2 16 829805 Cap, Fill Screw, Pan Hd. Trx Hi-Lo #6 x 3/4 17 830587 Cap, Screw 18 SP6519 Owner's Manual (not shown) Stock item o May be secured stores, • Any attempt List for Sears Humidifier Model No. 758.144105 to repair through this contro! repair is done by a qualified nearest Sears store, the Hardware assembly service or motor technician, 15 Department may create Repair service of most a hazard is available Sears retail unless at your For the repair or replacement parts you need Call 7 am - 7 pro, 7 days a week 1-800-366-PART (1-808-366-7278) For in-home major brand repair service Call 24 hours a day, 7 days a week 1 -S004-REPAIR (1-800-473-7247) For the location of a Sears Repair Service Center in your area Call 24 hours a day, 7 days a week 1-800-488-1 222 Fer infermatien en purchasing a Sears Maintenance Agreement erte inquire abeut an existing Agreement Call 9 am - 5 pro, Monday-Saturday 1-800-827-6655 Atr_er_ca5 Nep_ir Spc2cl,'_ti._s The medel number will be found on the Numidifier identificatienlabel. When requesting service or erdering parts, always provide the fellewing information: ProductType _ Model Number Part Number _ Part Descriptien @ 2003 Emerson Sears, Roebuck Part. No. SP6519 and Co, Form. Hofrman Estates, No. SP6519 IL 60179 U.S.A. Printed in Canada 07/03