Download Energic Plus MVM User`s manual
Transcript
Battery charger MVM USER'S MANUAL MAIN SUPPLY VOLTAGE PRESET Attention: These settings can be done by qualified personnel only. For more information please contact the manufacturer. The charger is set by default in position 2 (input voltage 240 Vac). If the input voltage is different, the output current may change. It’s possible to adjust the charge current by following these steps: • • • • • • • Disconnect the charger from main supply and battery; Open the cabinet; Find the plugs for input voltage setting; Disconnect the wire A from the original plug; Connect the wire A to the correct position (220, 230, 240 or 250 Vac); Close the cabinet; Connect the charger to main supply. POSITION VOLTAGE 4 250 3 240 2 230 1 220 __________________________________________________________________________________________________________________________________________________ Code: OWM-MVM-261006 Page 8/9