Download Daikin BRC4C64 User`s manual
Transcript
Warning Daikin Industries, Ltd.’s products are manufactured for export to numerous countries throughout the world. Daikin Industries, Ltd. does not have control over which products are exported to and used in a particular country. Prior to purchase, please therefore confirm with your local authorised importer, distributor and/or retailer whether this product conforms to the applicable standards, and is suitable for use, in the region where the product will be used. This statement does not purport to exclude, restrict or modify the application of any local legislation. PCS0316H Ask a qualified installer or contractor to install this product. Do not try to install the product yourself. Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion. Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer or contractor to install those parts and accessories. Use of unauthorised parts and accessories or improper installation of parts and accessories can result in water or refrigerant leakage, electrical shock, fire or explosion. Read the User's Manual carefully before using this product. The User's Manual provides important safety instructions and warnings. Be sure to follow these instructions and warnings. If you have any enquiries, please contact your local importer, distributor and/or retailer. AIR CONDITIONING SYSTEM COOLING ONLY HE AT PUMP Cautions on product corrosion 1. Air conditioners should not be installed in areas where corrosive gases, such as acid gas or alkaline gas, are produced. 2. If the outdoor unit is to be installed close to the sea shore, direct exposure to the sea breeze should be avoided. If you need to install the outdoor unit close to the sea shore, contact your local distributor. JMI-0107 JQA-1452 About ISO 9001 ISO 9001 is a plant certification system defined by the International Organization for Standardization (ISO) relating to quality assurance. ISO 9001 certification covers quality assurance aspects related to the “ design, development, manufacture, installation, and supplementary service” of products manufactured at the plant. About ISO 14001 ISO 14001 is the standard defined by the International Organization for Standardization (ISO) relating to environmental management systems. Our group has been acknowledged by an internationally accredited compliance organisation as having an appropriate programme of environmental protection procedures and activities to meet the requirements of ISO 14001. Dealer Head Office: Umeda Center Bldg., 2-4-12, Nakazaki-Nishi, Kita-ku, Osaka, 530-8323 Japan Tokyo Office: JR Shinagawa East Bldg., 2-18-1, Konan, Minato-ku, Tokyo, 108-0075 Japan http://www.daikin.com/global_ac/ c All rights reserved Printed in Japan 05/08/005 SW • HP • SS Specifications, designs and other content appearing in this brochure are current as of May 2008 but subject to change without notice. C r e a t io n o f C o m fo r t [ 50 Hz ] [ 50 Hz ] Stores often feature the latest in designed decor. This refined beauty attracts people. Meanwhile, offices have a functional beauty. This encourages those within to work hard and apply intelligence and passion to their tasks. In either situation, a certain elegance should fill the space because thinking minds require high quality air conditioning. SkyAir by D aikin realise a comfortable indoor environment. All over the world, stores, offices, and homes prefer the low operating sound, attractive 1 2 Cooling only Capacity HP The values given for 1 HP is for FDGB type, 1.5 HP–6 HP is for FHYC type, 7 HP is for FDMG type, 8 HP–20 HP is for FD type. kW 1 1.5 2 2.5 3 4 5 6 7 8 10 15 20 2.6 3.5 5.3 6.4 7.7 10.5 12.8 14.2 16.8 24.0 29.2 47.9 58.4 Btu/h 8,900 11,900 18,100 21,800 26,200 35,700 43,600 48,400 57,500 81,800 99,600 163,500 199,400 kcal/h 2,250 3,010 4,560 5,500 6,600 9,000 11,000 12,200 14,400 20,600 25,100 41,200 50,200 FHC35KVE FHC50KVE FHC60KVE FHYC71KVE FHYC100KVE FHYC125KVE FHYC140KVE R35GV1 R50GV1 R60GV1 R71LUV1 / Y1 R100LUV1 / Y1 R125LUY1 R140LUY1 FH35BVE FH50BVE FH60BVE FHY71BVE FHY100BVE FHY125BVE R35GV1 R50GV1 R60GV1 R71LUV1 / Y1 R100LUV1 / Y1 R125LUY1 CEILING MOUNTED CASSETTE TYPE Page 11– 14 Specifications Dimensions Indoor unit Page 39 Page 60 Outdoor unit CEILING SUSPENDED TYPE Page 15– 16 Specifications Dimensions Indoor unit Page 39 Page 60 Outdoor unit CEILING SUSPENDED CASSETTE TYPE Page 17– 18 Specifications Dimensions Page 40 Page 61 Indoor unit FUY71FJV1 FUY100FJV1 FUY125FJV1 Outdoor unit R71LUV1 / Y1 R100LUV1 / Y1 R125LUY1 CEILING MOUNTED CASSETTE CORNER TYPE Page 19– 20 Specifications Dimensions Indoor unit Page 40 Page 61 Outdoor unit FHK35FV1 FHK45FV1 FHK60FV1 FHYK71FJV1 R35GV1 R50GV1 R60GV1 R71LUV1 / Y1 FHB35FV1 FHB45FV1 FHB60FV1 FHYB71FV1 FHYB100FV1 FHYB125FV1 R35GV1 R50GV1 R60GV1 R71LUV1 / Y1 R100LUV1 / Y1 R125LUY1 CEILING MOUNTED BUILT-IN TYPE Page 21– 22 Specifications Dimensions Page 41 Page 62 Indoor unit Outdoor unit WALL MOUNTED TYPE Page 23– 24 Specifications Dimensions Page 41 Page 62,63 FAY71LVE FAY100FAVE R71LUV1 / Y1 R100LUV1 / Y1 Indoor unit FVY71LAVE FVY100LAVE FVY125LAVE Outdoor unit R71LUV1 / Y1 R100LUV1 / Y1 R125LUY1 Indoor unit Outdoor unit FLOOR STANDING TYPE Page 25– 26 Specifications Dimensions Page 42 Page 63 PACKAGED AIR CONDITIONERS LOW STATIC PRESSURE TYPE Specifications Page 42 Dimensions Page 64 Indoor unit Outdoor unit DUCT CONNECTION FDBG25AVE FDBG35AVE FDBG50AVE FDBG60AVE FDBG71AVE R25JV1 R35JV1 R50GV1 R60GV1 R71FUV1 / Y1 MIDDLE STATIC PRESSURE TYPE Specifications Page 43 Dimensions Page 64,65 Page 27– 30 (FDMG) (FDMG) (FDYM) (FDYM) (FDMG) (FDMG) (FDYM) Indoor unit FDMG71AV1 FDMG100AV1 FDMG125AV1 FDMG140AV1 FDMG180AV1 Outdoor unit Indoor unit RG71AV1 / Y1 R100FUV1 / Y1 R125FUY1 RG140AY1 RG180AY1 FDYM03FAV1 FDYM04FAV1 FDYM05FAV1 FDYM06FAV1 Outdoor unit R71LUV1 / Y1 R100LUV1 / Y1 R125LUY1 R140LUY1 Indoor unit FD03KY1 FD04KY1 FD05KY1 FD06KY1 FD08KY1 FD10KY1 FD15KY1 FD20KY1 Outdoor unit Outdoor unit R71FUY1 R100FUY1 R125FUY1 RU06KY1 RU08KUY1 RU08KY1 RU10KUY1 RU10KY1 RU08KUY1 × 2 RU08KY1 × 2 RU10KUY1 × 2 RU10KY1 × 2 RU08KUY1 RU08KY1 RU10KUY1 RU10KY1 RU08KUY1 × 2 RU08KY1 × 2 RU10KUY1 × 2 RU10KY1 × 2 HIGH STATIC PRESSURE TYPE Specifications Page 44,45 Dimensions Page 65– 67 (Type without factory charged refrigerant) OUTDOOR UNIT Page 33– 34 Dimensions Page 68– 74 R25JV1 3 R35GV1 R35JV1 R50GV1 R60GV1 R71LUV1 R71LUY1 R71FUY1 RG71AV1 R100LUV1 R100FUY1 RG71AY1 R100LUY1 R100FUV1 R125LUY1 R125FUY1 R140LUY1 RU06KY1 RG140AY1 RG180AY1 4 Cooling only Simultaneous operation system HP Capacity The values given on the right are for the FHYC type. Page 31– 32 TWIN MULTI OPERATION 3 4 Specifications Page 46– 48 5 6 8 10 kW 7.7 10.5 12.8 14.2 22.2 26.6 Btu/h 26,200 35,700 43,600 48,400 75,800 90,800 kcal/h 6,600 9,000 11,000 12,200 19,100 22,900 FHYC35KVE × 2 FHYC50KVE × 2 FHYC60KVE × 2 FHYC71KVE × 2 FHYC100KVE × 2 FHYC125KVE × 2 R71LUV1 / Y1 R100LUV1 / Y1 R125LUY1 R140LUY1 R200KUY1 R250KUY1 Simultaneously running 2 to 4 units distributes comfort across wide spaces. CEILING MOUNTED CASSETTE TYPE Indoor unit Outdoor unit Simultaneous control with 2 units in spacious space CEILING SUSPENDED TYPE Indoor unit Outdoor unit FHY35BVE × 2 FHY50BVE × 2 FHY60BVE × 2 FHY71BVE × 2 FHY100BVE × 2 FHY125BVE × 2 R71LUV1 / Y1 R100LUV1 / Y1 R125LUY1 R140LUY1 R200KUY1 R250KUY1 FDYM04FAV1 × 2 FDYM05FAV1 × 2 R200KUY1 R250KUY1 R200KUY1 R250KUY1 DUCT CONNECTION MIDDLE STATIC PRESSURE TYPE Indoor unit Outdoor unit Simultaneous control with 3 units for irregularly shaped space OUTDOOR UNIT Page 33– 34 R71LUV1 R71LUY1 Simultaneous operation system Capacity The values given on the right are for the FHYC type. R100LUV1 R100LUY1 R125LUY1 R140LUY1 Page 31– 32 TRIPLE MULTI OPERATION Specifications Page 46– 48 Simultaneous operation system DOUBLE TWIN MULTI OPERATION Page 31– 32 Specifications Page 46– 48 HP 6 8 8 10 kW 14.2 22.2 22.2 26.6 Btu/h 48,400 75,800 75,800 90,800 kcal/h 12,200 19,100 19,100 22,900 FHYC50KVE × 3 FHYC71KVE × 3 FHYC50KVE × 4 FHYC60KVE × 4 R140LUY1 R200KUY1 R200KUY1 R250KUY1 FHY50BVE × 3 FHY71BVE × 3 FHY50BVE × 4 FHY60BVE × 4 R140LUY1 R200KUY1 R200KUY1 R250KUY1 R200KUY1 R250KUY1 Simultaneous control with 4 units for large space CEILING MOUNTED CASSETTE TYPE Indoor unit Outdoor unit CEILING SUSPENDED TYPE Indoor unit Outdoor unit DUCT CONNECTION MIDDLE STATIC PRESSURE TYPE FDYM03FAV1 × 3 Indoor unit Outdoor unit R200KUY1 OUTDOOR UNIT Page 33– 34 R140LUY1 5 R200KUY1 6 Heat pump 1.5 3.75 2 5.2 2.5 6.15 3 7.7 4 10.4 5 12.8 6 14.2 8 22.2 10 27.1 15 43.5 20 53.0 Btu/h 12,800 17,800 21,000 26,200 35,300 43,600 48,400 75,700 92,500 148,000 181,000 kcal/h 3,230 4,470 5,290 6,600 8,900 11,000 12,220 19,100 23,300 37,400 45,600 kW 4.22 5.8 7.0 7.9 11.2 14.2 16.3 23.2 29.5 44.8 56.8 Btu/h 14,400 19,800 23,900 27,000 38,100 48,400 56,000 79,200 100,700 153,000 194,000 kcal/h 3,630 4,990 6,020 6,800 9,600 12,200 14,000 20,000 25,400 38,500 48,800 Indoor unit HP Capacity kW Cooling The values given on the right are for the FHYC type. Values for other Heating types may differ slightly. The values given for 8HP to 20HP are for the FDY type. CEILING MOUNTED CASSETTE TYPE Page 11– 14 Specifications Page 49 Dimensions Page 60 FHYC35KVE FHYC50KVE FHYC60KVE FHYC71KVE FHYC100KVE FHYC125KVE FHYC140KVE Outdoor unit RY35FV1A RY50GAV1A RY60GAV1A RY71LUV1 / Y1 RY100LUV1 / Y1 RY125LUY1 RY140LUY1 Indoor unit FHY35BVE FHY50BVE FHY60BVE FHY71BVE FHY100BVE FHY125BVE Outdoor unit RY35FV1A RY50GAV1A RY60GAV1A RY71LUV1 / Y1 RY100LUV1 / Y1 RY125LUY1 FUY71FJV1 FUY100FJV1 FUY125FJV1 RY71LUV1 / Y1 RY100LUV1 / Y1 RY125LUY1 CEILING SUSPENDED TYPE Page 15– 16 Specifications Page 49 Dimensions Page 60 CEILING SUSPENDED CASSETTE TYPE Page 17– 18 Specifications Page 50 Dimensions Page 61 Indoor unit Outdoor unit CEILING MOUNTED CASSETTE CORNER TYPE Page 19– 20 Specifications Page 50 Dimensions Page 61 Indoor unit Outdoor unit FHYK35FJV1 FHYK45FJV1 FHYK60FJV1 FHYK71FJV1 RY35FV1A RY50GAV1A RY60GAV1A RY71LUV1 / Y1 FHYB35FV1 FHYB45FV1 FHYB60FV1 FHYB71FV1 FHYB100FV1 FHYB125FV1 RY35FV1A RY50GAV1A RY60GAV1A RY71LUV1 / Y1 RY100LUV1 / Y1 RY125LUY1 CEILING MOUNTED BUILT-IN TYPE Page 21– 22 Specifications Page 51 Dimensions Page 62 Indoor unit Outdoor unit WALL MOUNTED TYPE Page 23– 24 Specifications Page 51 Dimensions Page 62,63 Indoor unit Outdoor unit FAY71LVE FAY100FAVE RY71LUV1 / Y1 RY100LUV1 / Y1 FLOOR STANDING TYPE Page 25– 26 Specifications Page 52 Dimensions Page 63 Indoor unit Outdoor unit FVY71LAVE FVY100LAVE FVY125LAVE RY71LUV1 / Y1 RY100LUV1 / Y1 RY125LUY1 PACKAGED AIR CONDITIONERS DUCT CONNECTION LOW STATIC PRESSURE TYPE Specifications Page 52 Dimensions Page 64 Indoor unit Outdoor unit FDYB35KAVE FDYB50KAVE FDYB60KAVE FDYB71KAVE RY35FV1A RY50GAV1A RY60GAV1A RY71LUV1 / Y1 MIDDLE STATIC PRESSURE TYPE Specifications Page 53 Dimensions Page 64,65 Indoor unit FDYM03FAV1 FDYM04FAV1 FDYM05FAV1 FDYM06FAV1 Outdoor unit RY71LUV1 / Y1 RY100LUV1 / Y1 RY125LUY1 RY140LUY1 HIGH STATIC PRESSURE TYPE Specifications Page 54 Dimensions Page 65– 67 Page 27– 30 Indoor unit FDY06KAY1 FDY08KAY1 FDY10KAY1 FDY15KAY1 FDY20KAY1 Outdoor unit RY140LUY1 RY200KUY1 RY250KUY1 RY200KUY1 × 2 RY250KUY1 × 2 RY140LUY1 RY200KUY1 RY250KUY1 RY200KUY1 × 2 RY250KUY1 × 2 OUTDOOR UNIT Page 33– 34 7 Dimensions Page 68– 74 RY35FV1A RY50GAV1A RY60GAV1A RY71LUV1 RY71LUY1 RY100LUV1 RY100LUY1 RY125LUY1 8 Heat pump Simultaneous operation system HP Capacity Cooling / Heating The values given on the right are for the FHYC type. Page 31– 32 TWIN MULTI OPERATION 3 4 Specifications Page 54– 56 5 6 8 Simultaneously running 2 to 4 units distributes comfort across wide spaces. 10 kW 7.7/7.9 10.4/11.2 12.8/14.2 14.2/16.3 22.2/22.7 26.6/28.4 Btu/h 26,200/27,000 35,300/38,100 43,600/48,400 48,400/56,000 75,800/77,500 90,800/97,000 kcal/h 6,600/6,800 8,900/9,600 11,000/12,200 12,200/14,000 19,100/19,500 22,900/24,400 FHYC35KVE × 2 FHYC50KVE × 2 FHYC60KVE × 2 FHYC71KVE × 2 FHYC100KVE × 2 FHYC125KVE × 2 RY71LUV1 / Y1 RY100LUV1 / Y1 RY125LUY1 RY140LUY1 RY200KUY1 RY250KUY1 CEILING MOUNTED CASSETTE TYPE Indoor unit Outdoor unit Simultaneous control with 2 units in spacious space CEILING SUSPENDED TYPE Indoor unit FHY35BVE × 2 FHY50BVE × 2 FHY60BVE × 2 FHY71BVE × 2 FHY100BVE × 2 FHY125BVE × 2 Outdoor unit RY71LUV1 / Y1 RY100LUV1 / Y1 RY125LUY1 RY140LUY1 RY200KUY1 RY250KUY1 FDYM04FAV1 × 2 FDYM05FAV1 × 2 RY200KUY1 RY250KUY1 RY200KUY1 RY250KUY1 DUCT CONNECTION MIDDLE STATIC PRESSURE TYPE Indoor unit Outdoor unit Simultaneous control with 3 units for irregularly shaped space OUTDOOR UNIT Page 33– 34 RY71LUV1 RY71LUY1 Simultaneous operation system HP Capacity Cooling / Heating The values given on the right are for the FHYC type. RY100LUV1 RY100LUY1 RY125LUY1 RY140LUY1 Page 31– 32 TRIPLE MULTI OPERATION 6 Specifications Page 54– 56 8 Simultaneous operation system Page 31– 32 DOUBLE TWIN MULTI OPERATION 8 Specifications Page 54– 56 10 kW 14.2/16.3 22.2/22.7 22.2/22.7 26.6/28.4 Btu/h 48,400/56,000 75,800/77,500 75,800/77,500 90,800/97,000 kcal/h 12,200/14,000 19,100/19,500 19,100/19,500 22,900/24,400 FHYC50KVE × 3 FHYC71KVE × 3 FHYC50KVE × 4 FHYC60KVE × 4 RY140LUY1 RY200KUY1 RY200KUY1 RY250KUY1 FHY50BVE × 3 FHY71BVE × 3 FHY50BVE X 4 FHY60BVE × 4 RY140LUY1 RY200KUY1 RY200KUY1 RY250KUY1 FDYB71KAVE × 3 FDYB50KAVE × 4 FDYB60KAVE × 4 RY200KUY1 RY200KUY1 RY250KUY1 RY200KUY1 RY250KUY1 CEILING MOUNTED CASSETTE TYPE Indoor unit Outdoor unit Simultaneous control with 4 units for large space CEILING SUSPENDED TYPE Indoor unit Outdoor unit DUCT CONNECTION LOW STATIC PRESSURE TYPE Indoor unit Outdoor unit DUCT CONNECTION MIDDLE STATIC PRESSURE TYPE FDYM03FAV1 × 3 Indoor unit Outdoor unit RY200KUY1 OUTDOOR UNIT Page 33– 34 RY140LUY1 9 RY200KUY1 10 CEILING MOUNTED CASSETTE TYPE Sound level 35/ 30 CEILING MOUNTED CASSETTE TYPE High Low Unified square panels dB(A) All models from the 35K to 140K use the same size panel. Multiple unit installations maintain a physical uniformity that is aesthetically pleasing and make it easier to plan ceiling lighting systems and to design interiors. FHYC71K FH( Y) C 950 mm Cooling only FH(Y)C35KVE–140KVE Heat pump FHYC35KVE–140KVE Quiet, decor-blending form and easy installation in new or old buildings. Optimal comfort and convenience assured by 3 air discharge modes Same for all models Air direction Desired situation Draft prevention setting When drafts are unwanted Auto-swing 5-levels air direction setting Wireless LCD remote controller A s ignal rec eiver mus t be added to the indoor unit. 950 mm Compact body and quiet operation BRC1C61 Note: R emote c ontroller c able not inc luded. C ables must be proc ured loc ally. Signal receiver unit (Installed type) Cooling only BRC7C613W Heat pump BRC7C612W Indoor units use an aerodynamically designed Diffuser Turbo Fan Wireles s remote c ontroller and s ignal rec eiver unit are s old as a s et. Diffus er For gentle drafts (Ceiling is soiled.) Auto-s wing between 30° and 65° Settable to 5 different levels between 10° and 40° Settable to 5 different levels between 10° and 65° Settable to 5 different levels between 30° and 65° Draft prevention (In heating mode) At heating s tartup and thermo OFF*, air direc tion is automatic ally s et to a near horizontal 10˚ to prevent direc t expos ure to c ool Auto air direction control The air direc tion is s et automatic ally to the memoris ed pos ition of the previous air direc tion. (Initial s etting is 65˚ for heating and 30˚ for c ooling.) Multi-Flow System 4-way flow 1 pattern 4 pattern dB(A) Indoor unit High Low 35K 33 33 35 35 39 42 44 29 29 30 30 34 36 37 100K 125K 140K Wide air distribution A newly shaped air discharge opening increases flow without increasing wind speed, hence discharged air reaches farther than before. Air discharge distribution comparison •125K Draft resistance has been reduced by incorporating, into a single unit, an impeller and a diffuser to control air flow inside the unit. The Diffuser Turbo Fan is both quiet during operation and compact. 71K At heating startup and thermo OFF*, air discharge is automatically set to 30˚ to prevent both direct exposure to cool air drafts and con- Note: Air direc tion is s et to the s tandard pos ition when the unit is s hipped from the fac tory. The pos ition c an be c hanged from the remote c ontroller. *When the thermos tat turns off. B lade 60K When ceilings must be kept spotless Auto-s wing between 10° and 65° 3-way flow 50K Setting to prevent soiling of ceiling Auto-s wing between 10° and 40° Accessory required for indoor unit (option) Wired LCD remote controller Standard setting 2-way flow 2.5 m/sec 2 2.0 m/sec 1.5 m/sec 1.0 m/sec 1 0.5 m/sec 0.5 m/sec 3 pattern 4 (m) 3 2 1 0 1 2 " " denotes piping direction. " " denotes sealing member for air discharge outlet (option) . Air discharge temperature comparison Note: For 3-way or 2-way flow ins tallation, the s ealing member for air dis c harge outlet (option) mus t be us ed to c los e off the unus ed outlet(s ). (m) Conventional model 2.7 33˚C 30˚C 2 27˚C Air direction can be selected according to installation. Note: Operation s ound inc reas es when us ing 2-way or 3-way •125K 3 4 (m) (In heating) (m) 3.2 3 Super Cassette 1 3 33˚C 30˚C 27˚C 2 1 2 1 25˚C 25˚C 22˚C 4 (m) (m) 3.2 3 Super Cassette (m) Conventional model 2.7 2.5 m/sec 2.0 m/sec 2 1.5 m/sec 1.0 m/sec 1 22˚C 0 1 2 3 4 (m) Suitable for high ceilings Criteria for ceiling height and number of air discharge outlets Number of air discharge outlets used 35K–71K 4-way flow Standard Ceiling High ceiling height High ceiling Note : Anec hoic c hamber c onvers ion value, meas ured ac c ording to J IS parameters and 3-way flow 2-way flow 100K–140K 4-way flow 3-way flow 2-way flow 2.7 m 3.0 m 3.5 m 3.2 m 3.6 m 4.2 m 3.0 m 3.3 m 3.8 m 3.6 m 4.0 m 4.2 m 3.5 m 3.5 m 4.2 m 4.2 m - Note: Initial s ettings are for s tandard c eiling height and 4-way flow. High c eiling s ettings 1 and 2 are s et from the remote Programme "Dry" Two selectable temperature-sensors Both indoor unit and wired remote controller (option) contain temperaturesensors. Temperature sensing can be set at the unit or, to further improve comfort level, closer to the target area at the wired remote control. 11 Guide Line up P. 3–10 Outdoor units P. 33–34 Remote controllers P. 35–36 Standard specifications P. 39, 46, 49, 54 Options P. 57 Outer dimension drawings P. 60 *Temperature-s ens or on indoor unit mus t be us ed when the air c onditioner is c ontrolled from another room. **Wireles s remote c ontroller does not have a Dehumidification is microprocessor controlled to prevent abrupt and uncomfortable changes in air temperature. Switchable fan speed: High/Low 12 CEILING MOUNTED CASSETTE TYPE Easier to maintain Dust can be kept from blowing onto ceilings by directly setting flaps by hand or by remote control. The new long-life filter is 20% more efficient than the previous one. This has enabled further reductions in running costs by extending the heat-exchanger cleaning interval by once every two years to once every three years. Conventional Super Cassette *1 298 mm high with 100K – 140K *2 303 mm high with 100K – 140K U lt r a lo n g -life filt e r P a n e l s pa c e r Even in smoky environments where the air conditioning is on most of the time, the ultra long-life filter only has to be changed once a year. Use when only minimal space is available between drop ceilings and ceiling slabs. Smoky atmosphere: annual filter change *For dust concentration of 0.3 mg/m3 (Requires separately sold Air Cleaner.) 1 year (Approx. 5,000 hr) 15 hr/day x 28 day/month x 12 month/year S e a lin g m e m be r fo r a ir d is c h a r g e o u t le t 3 years Conventional Super Cassette H ig h -e ffic ie n c y filt e r B r a n c h d u c t c h a m be r Available in two types: 65% and 90% colorimetry. This chamber lets you connect a round flexible duct to the air discharge opening at any time after the original installation. F r e s h a ir in t a k e k it Less cleaning work thanks to "Non-dew Flaps" with non-flocking The use of non-flocking flaps minimises adnerring dart, so less cleaning work is needed. Installable in any direction Self-diagnosis function Using this kit, a duct can be fitted to increase the intake of outdoor air. Outside Note: *C onnec ting duc ts , ins ec t nets , fire dampers , air filters , and other parts s hould, as required, be proc ured loc ally. **Outs ide Air fan interloc ked with air c onditioning unit is nec es s ary. Optional PC B (K R P1C 63)is required for interloc king. ***It is rec ommended that the volume of outdoor air introduc ed through the kit is limited to 10% of the maximum airflow rate of the indoor unit. Introduc ing higher quantities will inc reas e the operating nois e and may als o influenc e temperature s ending. Low gas pressure detection Insufficient gas charging is normally hard to detect. During post-installation trials and regular inspection procedures, the refrigerant level is monitored by microprocessor to maintain proper gas pressure. The units can be installed in the following different ways. Chamber type (without T-joint pipe and fan) Kit name: KDDP55D160 Since the orientation of the intake grill can be adjusted after installing, the direction of the intake grill lines can be unified when multiple units are installed. Chamber type (with T-joint pipe and without fan) Kit name: KDDP55D160K Flexible duct (procured locally) Flexible duct T-joint pipe (procured locally) T-joint pipe Direct installation type Kit name: KDDJ55X160 Suction chamber Connection chamber Figure 1) Signal receiver unit Notes : R equires an ins pec tion port for maintenanc e ac c es s . For dual intake duc t ins tallation only. If only a s ingle intake duc t c an be c onnec ted bec aus e of an obs truc tion, etc ., K DDP55D160 s hould be us ed ins tead. It is not pos s ible to us e this kit s imultaneous ly with the wireles s remote c ontroller. Refrigerant piping Notes: R equires an inspection port for maintenance access. If intake ducts cannot be connected to both connection chambers due, for example, to an obstruction, single intake duct installation is possible. Figure 1 shows what the installation will look like 750 mm Note: Us e of options will inc reas e operating s ound. Cooling only Heat pump DoubleTwin Multi Operation *1Applic able *2Applic able *3Applic able *4Applic able *1 *2 *4 *4 *1 *3 *4 *4 Option Others PE fin Auto-res tart Control features S elf-diagnos is func tion E mergenc y operation Low gas pres s ure detec tion C eiling s oiling prevention Filter s ign Long-life filter Pre c harged for up to 30 m Work & Servicing Drain pump mec hanis m Mould res is tant treatment for filter Year-round c ooling applic able Hot s tart Two s elec table temperature-s ens ors S witc hable fan s peed Draft prevention func tion Model S wing pattern s elec tion Auto s wing The high-performance filter and other options are easily clipped into place. There is no need for a screwdriver. Supports simultaneous running of the twin, triple, and double twin multi operation. Mould prevention Comfort High c eiling applic ation Easy installation for options (Features are explained on P. 37–38.) Feature Programme "Dry" Features Triple Multi Operation Intake duct (procured locally) Intake duct Connection (procured locally) chamber (duct length: 4 m max.) Intake duct (procured locally) (duct length: 4 m max.) Drain pump is equipped as standard accessory with 750 mm lift. Duct flange (with insulation material) Suction chamber Twin / triple / double twin multi operation All models suspended without lift 2 years High-effic ienc y filter Note: If the wireless remote c ontrol option is installed, a light rec eptor unit is housed in one of the adjuster poc k- Move to 0° 1 Move to des ired angle Sealing members block air discharge openings not used in 2-way or 3-way blow. Fres h air intake kit Each corner of the unit has an Adjuster Pocket that lets you easily adjust the unit's suspended height. 1 2 *For dust concentration of 0.15 mg/m3 4 years (Approx. 10,000 hr) 8 hr/day x 25 day/month x 4 years Ultra long-life filter Easy height adjustment less ce ilin dirt tha g Move flaps n before direc tly to des ired angle Heat-exchanger cleaning interval 258 mm 40 mm Ordinary store or office: filter change every 4 years 30%—40% Twin Multi Operation Note: S ome c eiling c ons truc tions may hinder ins tallation. 40 mm C ontac t your DaiPanel spacer Panel spacer kin Dealer before ins talling your unit. For 35K–71K indoor units For 100K–140K indoor units 200 mm Interloc k c ontrol 245 mm *2 Heat exchanger cleaning required only once every 3 years Timer s elec tor 240 mm *1 Stepping motor controls flaps to prevent soiled ceilings C entral remote c ontrol Just 240 mm high. Installable in tight ceiling spaces (35K–71K) Options required for specific operating environments Auto-c ooling/heating c hange-over C ontrol by 2 remote c ontrollers C ontrol by 1 remote c ontroller E xternal c ommand c ontrol Quick and easy to install when wired remote c ontroller is us ed to R 71LU– R 140LU outdoor units (for temp. down to – 15°C ) (An option is required.) to R Y71LU– R Y140LU outdoor units (for temp. down to – 5°C ) and R Y200LU– R Y250LU outdoor units (for temp. down to – 0°C ) to R (Y)71LU– 140LU outdoor units See pages 31–32 for details of the Multi Series. 13 14 CEILING SUSPENDED TYPE Sound level CEILING SUSPENDED TYPE 39/ 35 High Low Spreads comfortable air throughout the room dB(A) Auto-swing for comfort in all directions FHY71B Both indoor unit and wired remote controller (option) contain temperature-sensors. Temperature sensing can be set at the unit or, to further improve comfort level, closer to the target area at the wired remote control. dB(A) Accessory required for indoor unit (option) Wired LCD remote controller A s ignal rec eiver mus t be added to the indoor unit. BRC1C61 Note: R emote c ontroller c able not inc luded. C ables must be proc ured loc ally. Cooling only BRC7EA66 Heat pump BRC7E63W Wireles s remote c ontroller and s ignal rec eiver unit are s old as a s et. 37 38 38 39 42 44 32 33 33 35 37 39 125B Note : Anec hoic c hamber c onvers ion value, meas ured ac c ording to J IS parameters and Uses quiet stream fan and other quiet technologies. Sound damper Installation flexibility for freedom of design Drain pump kit (option) can be easily incorporated Uniform height and depth. Compact design for small-capacity models to meet tighter dimensional constraints. Signal receiver unit (Installed type) 35B 71B Switchable fan speed: High/Low Wireless LCD remote controller Low 100B Dehumidification is microprocessor controlled to prevent abrupt and uncomfortable changes in air temperature. Installable on ceilings 3.5 m high High 60B Programme "Dry" 100° Indoor unit 50B *Temperature-sensor on indoor unit must be used when the air c onditioner is c ontrolled from another room. **Wireless remote controller does not have a temperaturesensor. Cooling only FH(Y)35BVE–125BVE Heat pump FHY35BVE–125BVE Upgrade to a quiet and compact system. Sound operation has been reduced on the exposed ceiling suspended type unit. Two selectable temperature-sensors Wide air discharge openings produce a spreading 100° airflow FH( Y) Quiet operation Drain pipe connection can be done inside the unit. Refrigerant and drain pipe outlets are at the same opening. (mm) Indoor unit 35B/50B 60B/71B 100B Height Width Depth 125B 195 960 1,160 1,400 Two time settings (2500 hrs and 1250 hrs) are available to match the installation environment. Maintenance time warning is displayed on the remote controller (filter sign). Non-dew flap without bristles All wiring and internal servicing done from below the unit The unit fits more snugly into tight spaces. Absence of bristles minimises clinging dirt and simplifies cleaning. Pipes more easily rigged, too For 71B indoor unit Non-dew flap Plastic panels are used to conceal piping holes. Holes can be easily punched out without requiring special tools. Dimens ions in brac kets are for previous model. 1,160 mm (1,300 mm) 1,220 mm (1,420 mm) * For dust concentration of 0.15 mg/m3 Drain pump kit (built inside main unit) Reduced edge space, more flexible installation (60 mm) Long-life filter lasts about 1 year * Maintenance not required 600 mm Weight of all models reduc ed (down 10% c ompared with previous models ). Trans fer and ins tallation work is les s arduous . 30 mm Easy-clean, flat surfaces It is easy to wipe dirt off the flat side and lower surfaces of the unit. For all maintenance tasks, access is from bottom surface. (60 mm) Low gas pressure detection *Water used in the test-run can now be drained from the air discharge opening rather than from the side as was formerly the case. Quiet stream fan Easier to maintain 1,590 680 30 mm Turbulent flow Straightening is produced vane Improved-oil resistant grille Supports simultaneous running of the twin, triple and double twin multi operation. Twin Multi Operation Triple Multi Operation Oil-resistant plastic is used for the air discharge grille. This improves durability in restaurants and other similar environments. DoubleTwin Multi Operation Note: Intended for use in salons, dining rooms, and ordinary sales floors, this specification is not suitable for kitchens or other harsh environments. See pages 31–32 for details of the Multi Series. (Features are explained on P. 37–38.) 15 Guide Line up P. 3–10 Outdoor units P. 33–34 Remote controllers P. 35–36 Standard specifications P. 39, 47, 49, 55 Options P. 57 Outer dimension drawings P. 60 *1Ins tallable on max. 3.5 m high c eiling *4Applic able to R Y71LU– R Y140LU outdoor units (for temp. down to – 5°C ) *2Applic able when wired remote c ontroller is us ed and R Y200LU– R Y250LU outdoor units (for temp. down to – 0°C ) *3Applic able to R 71LU– R 140LU outdoor units (for temp. down to – 15°C *5Optional ) available 6 * Applic able to R (Y)71LU– 140LU outdoor units (An option is required.) PE fin Twin / triple / double twin multi operation Others Interloc k c ontrol C entral remote c ontrol E xternal c ommand c ontrol C ontrol by 1 remote c ontroller C ontrol by 2 remote c ontrollers Auto-c ooling/heating c hange-over Auto-res tart Control features S elf-diagnos is func tion E mergenc y operation Low gas pres s ure detec tion Filter s ign *6 Long-life filter *6 *6 Mould-proofing drain pan Pre c harged for up to 30 m Mould res is tant treatment for filter *6 *5 Timer s elec tor *5 *4 Year-round c ooling applic able *3 *2 Hot s tart *2 Two s elec table temperature-s ens ors High c eiling applic ation *1 S witc hable fan s peed Draft prevention func tion Work & Servicing Drain pump mec hanis m Cooling only Heat pump Auto s wing Model Mould prevention Comfort Feature Programme "Dry" Features 16 CEILING SUSPENDED CASSETTE TYPE Sound level High Low The auto-swing function increases comfort level dB(A) Ultra-thin with quiet operation Auto-swing 5-levels air direction setting Auto-air direction control Auto-swing between 0° and 60° Settable to 5 different levels between 0° and 60° The air direction is set automatically to the memorised position of the previous air direction. (Initial setting is 60° for heating and 30° for cooling.) Thinner usually means noisier, but Daikin's exclusive technology has solved this. FUY71FJ Heat exchanger Ultra-thin, quiet design made possible by new Flat Turbo Fan. At heating startup and thermo OFF*, air direction is automatically set to horizontal Draft prevention (in heating) Through use of a high-static-pressure vane and a thorough reduction in flow loss in the path between internal fan suction and air output, we have achieved a thinner fan unit and quiet operation while maintaining airflow. *When the thermos tat turns off. Air direction can be selected according to installation Selection patterns for air direction and fan speed ratio Note: Applicable only to the flow configurations shown below. Wireless LCD remote controller *R equires sealing member for air disc harge outlet (optional ac c essory) for opposing 2- Moderate (approx. 70%) dB(A) 2-way flow BRC1C61 Note: R emote c ontroller c able not inc luded. C ables must be proc ured loc ally. Cooling only BRC7C529W Heat pump BRC7C528W Wireles s remote c ontroller and s ignal rec eiver unit are s old as a s et. Suitable for high ceilings Two selectable temperature-sensors Criteria for ceiling height and number of air discharge outlets Both indoor unit and wired remote controller (option) contain temperaturesensors. Temperature sensing can be set at the unit or, to further improve comfort level, closer to the target area at the wired remote control. Standard 3.5 m 3.8 m — Ceiling High ceiling 1 height High ceiling 2 3-Way 3-wayAirflow Flow 4-Way 4-wayAirflow Flow 3.0 m 3.3 m 3.5 m 2.7 m 3.0 m 3.5 m Note: Initial s ettings are for s tandard c eiling height and 4-way flow. High c eiling s ettings 1 and 2 are s et from the remote Simply lock the body in place with suspension bolts to install. Adjustment is smooth and simple, too. Dehumidification is microprocessor controlled to prevent abrupt and uncomfortable changes in air temperature. Since the orientation of the intake grill can be adjusted after installing, the direction of the intake grill lines can be unified when multiple units are installed. Accessible from below for easy maintenance (Features are explained on P. 37–38.) Cooling only Heat pump 17 Outer dimension drawings P. 61 *1 *2 *4 *4 *1 *3 *4 *4 Control features S elf-diagnos is func tion E mergenc y operation Low gas pres s ure detec tion Filter s ign Long-life filter Pre c harged for up to 30 m Work & Servicing Drain pump mec hanis m Mould-proofing drain pan Timer s elec tor Year-round c ooling applic able Hot s tart Two s elec table temperature-s ens ors High c eiling applic ation S witc hable fan s peed Draft prevention func tion S wing pattern s elec tion Auto-s wing Mould res is tant treatment for filter Mould prevention Comfort Feature Model Note: The panel cannot be turned when the wireless remote controller is in use. Low gas pressure detection Programme "Dry" Features T-type hexagon wrench Installable in any direction Easier to maintain * For dust concentration of 0.15 mg/m3 Hook 500 mm Switchable fan speed: High/Low Long-life filter lasts about 1 year * Maintenance not required Suspension bolt Drain pump is equipped as standard accessory with 500 mm lift. *Temperature-sensor on indoor unit must be used when the air c onditioner is c ontrolled from another room. **Wireless remote controller does not have a Programme "Dry" Options P. 57 35 38 39 Simple installation procedure Number of air discharge outlets used Standard specifications P. 40 and 50 40 43 44 Quick and easy to install 2-way flow Remote controllers P. 35–36 71FJ Note : Anec hoic c hamber c onvers ion value, meas ured ac c ording to J IS parameters and Note: When 2- or 3-way flow configurations are selected, the unused flow outlets must be blocked off with the optional sealing material. Sound during operation will rise by about 2 dB. Outdoor units P. 33–34 Low 125FJ 3-way flow 4-way flow Guide Line up P. 3–4, 7–8 High 100FJ Piping position Signal receiver unit (Installed type) Indoor unit *1Applic able when wired remote c ontroller is us ed *3Applic able to R Y71LU– 125LU outdoor units (for temp. down to – 5°C ) *2Applic able to R 71LU– 125LU outdoor units (for temp. down to – 15°C*4)Applic able to R (Y)71LU– 125LU outdoor units (An option is required.) E xternal c ommand c ontrol C entral remote c ontrol A s ignal rec eiver mus t be added to the indoor unit. Standard (100%) C ontrol by 1 remote c ontroller Wired LCD remote controller C ontrol by 2 remote c ontrollers Flexibility in installation location. Installation is also simple. Accessory required for indoor unit (option) Auto-c ooling/heating c hange-over Cooling only FUY71FJV1–125FJV1 Heat pump FUY71FJV1–125FJV1 Auto-res tart FUY Sliding shutter Closes to moderate airflow (70%) Others PE fin 40/ 35 Interloc k c ontrol CEILING SUSPENDED CASSETTE TYPE 18 CEILING MOUNTED CASSETTE CORNER TYPE Sound level 41/ 36dB(A) CEILING MOUNTED CASSETTE CORNER TYPE High Multiple airflow variations for stepped or 3.8 m high ceilings Low 1 Downward flow FHYK71FJ FHYK71FJ Quiet operation dB(A) 2 Downward flow + Forward flow Indoor unit High Low 35F(J) 39 39 41 41 33 34 36 36 3 Forward flow 45F(J) Airflow variation FH( Y) K 60F(J) 71F(J) Note : Anec hoic c hamber c onvers ion value, meas ured ac c ording to J IS parameters and Auto-swing Cooling only FH(Y)K35FV1–71F(J)V1 Heat pump FHYK35FJV1–71FJV1 Easier to install and service High ceiling installation R equires ceiling tap cutting. R equires ceiling tap cutting. Air dis c harge grille, flexible duc t Required options Fits in ceiling corners. Equipped for versatile airflow control. Accessory required for indoor unit (option) Wired LCD remote controller Panel spacers (option) can be installed with all three airflow variations. Decoration panels (option) to hide the downward air discharge opening can be installed with variation 3 above. 500 mm E x a m ple in s t a lla t io n s In the corner of a room (downward flow) Comfortable cooling from ceiling to floor (downward flow) Wind speed profile Heating (65° downward flow ... Standard installation) BRC1C61 Note: R emote c ontroller c able not inc luded. C ables must be proc ured loc ally. Drain pump is equipped as standard accessory with 500 mm lift. Not s uited for high c eilings because air currents do not (m) 3.8 3 2.0 m/s 1.5 m/s 1.0 m/s 0.5 m/s 0.3 m/s 1 1 2 3 4 * For dust concentration of 0.15 mg/m3 Low gas pressure detection Fresh air intake possible Air c onditioner 2.0 m/s 1.5 m/s 1.0 m/s 0.5 m/s 0.3 m/s 2 1 5 Long-life filter lasts about 1 year * Maintenance not required Wind speed profile On stepped ceilings, downward flow Heating (65° downward flow from high ceiling) can be blocked and outward flow alone can be used to cool or heat the space. 3 2 On stepped ceiling (Outward (outward + downward flow) 6 (m) 1 2 3 4 5 (Site installation required) A duct can be connected to the rear of the indoor unit to draw in outdoor air. C over here with dec orative panel. Dec orative panel (s old s eparately) Decorative panels (option) can be installed on the downward air discharge opening to close gaps without stepped room interiors. 6 K eep duc t no more than 5 m long. Optimal comfort and convenience assured by three air discharge modes Draft prevention setting Air direction When drafts are unwanted Desired situation Auto-swing 5-levels air direction setting Standard setting Note: The maximum duc t length for c onnec tion to the fres h air intake kit is 5 m. C onnec ting duc ts , ins ec t nets , fire dampers , air filters , and other parts s hould, as required, be Setting to prevent soiling of ceiling For gentle drafts (Ceiling is soiled.) When ceilings must be kept spotless P a n e l s pa c e r ( o pt io n ) Auto-s wing between 0° and 65° Auto-s wing between 0° and 65° Auto-s wing between 0° and 65° Settable to 5 different levels between 0° and 65° Settable to 5 different levels between 30° and 65° Settable to 5 different levels between 40° and 65° Use when only minimal space is available between drop ceilings and ceiling slabs. 20mm C eiling Panel s pac er Draft prevention (In heating) model At heating s tartup and thermo OFF*, air dis c harge is automatic ally s et to a near horizontal 10˚ to prevent direc t expos ure to c ool air drafts . Upgrade options for easy installation on stepped ceilings Air dis c harge grille The air direc tion is s et automatic ally to the memoris ed pos ition of the previous air direc tion. (Initial s etting is 65° for heating and 30° for c ooling.) Auto air direction control Flexible duc t Note: Air direc tion is s et to the s tandard pos ition when the unit is s hipped from the fac tory. The pos ition c an be c hanged from the remote c ontroller. *When the thermos tat turns off. Programme "Dry" Dehumidification is microprocessor controlled to prevent abrupt and uncomfortable changes in air temperature. Cooling only Heat pump 19 Guide Line up P. 3–4, 7–8 Outdoor units P. 33–34 Remote controllers P. 35–36 Standard specifications P. 40 and 50 Options P. 58 Outer dimension drawings P. 61 *1 *3 *3 *2 *3 *3 *1Applic able to R 71LU outdoor units (for temp. down to – 15°C ) (An option is required.) *2Applic able to R Y71LU outdoor units (for temp. down to – 5°C ) *3Applic able to R (Y)71LU outdoor units PE fin Others Interloc k c ontrol C entral remote c ontrol E xternal c ommand c ontrol C ontrol by 1 remote c ontroller Auto-c ooling/heating c hange-over C ontrol by 2 remote c ontrollers Auto-res tart S elf-diagnos is func tion Control features E mergenc y operation Low gas pres s ure detec tion C eiling s oiling prevention Filter s ign Long-life filter Pre c harged for up to 30 m Work & Servicing Drain pump mec hanis m Timer s elec tor Year-round c ooling applic able Hot s tart High c eiling applic ation Programme "Dry" Draft prevention func tion S wing pattern s elec tion Mould res is tant treatment for filter Mould prevention Comfort Auto s wing Model For outward blow, detach the punch-out panel from the duct-connection port on the front of the unit. (Features are explained on P. 37–38.) Feature S witc hable fan s peed Features Switchable fan speed: High/Low 20 CEILING MOUNTED BUILT-IN TYPE Sound level CEILING MOUNTED BUILT-IN TYPE 41/ 35 High Low Flexibly adapts to shop interiors dB(A) Meets diverse of installation needs To cope with the challenges of Lshaped or U-shaped spaces, it is possible to install the air discharge unit away from the main unit. At the same time, different types of architectural space can be kept comfortable. FHYB71F FH( Y) B The indoor unit can be installed in rooms with as little as 350 mm between the drop ceiling and ceiling slab. It also works with both flexible and ordinary ducts. S t a n d a r d in s t a lla t io n e x a m ple s In crawl space 6 With canvas bellows and air intake panel (sold separately) 2 Air conditioner 4 2 Air conditioner 350 mm or more 4 6 5 1 Air blow Cooling only FH(Y)B35FV1–125FV1 Heat pump FHYB35FV1–125FV1 425 mm or more Long-life filter Air intake Long-life filter 5 W it h h ig h -e ffic ie n c y filt e r C e ilin g r e t u r n 2 Air conditioner 2 Air conditioner Accessory required for indoor unit (option) Wired LCD remote controller U-shaped space Long space 4 13 6 540 mm or more 7 5 1 Air intake Air blow Air blow C e iling re turn w ith high-e ffic ie nc y filte r 2 Air conditioner 6 4 9 11 7 W it h o r d in a r y d u c t s Ordinary duct (procured locally) 540 mm or more Air intake 8 5 Options 1 dB(A) Low 35F 38 39 41 41 41 44 32 34 35 35 35 38 60F 71F 100F 125F 2 4 3 Decorative panel Air discharge opening adapter Canvas bellows and air intake panel Air intake Air blow 5 High 6 7 8 Flexible duct Air discharge grille Air discharge chamber High-performance filter Inspection panel Drain pump is equipped as standard accessory with 250 mm lift. 250 mm 9 10 11 12 13 External static pressure can be set depending on duct length, presence of high-efficiency filter, and other installation conditions. Indoor unit High Standard Low 35F–71F 78 98 39 39 20 100F and 125F Fresh air intake possible Easier to maintain Note: The maximum duct length for connection to the fresh air intake kit is 5 m. C onnecting ducts, insect nets, fire dampers, air filters, and other parts should, as required, Low gas pressure detection Insufficient gas charging is normally hard to detect. During post-installation trials and regular inspection procedures, the refrigerant level is monitored by microprocessor to maintain proper gas pressure. Remote controllers P. 35–36 Standard specifications P. 41, 51 Options P. 58 Outer dimension drawings P. 62 H ig h -e ffic ie n c y filt e r ( o pt io n ) Available in two types: 65% and 90% colorimetry. This filter easily meets dust collection efficiency regulations specified in building codes. Options have also been upgraded to make installation even easier. Air discharge opening adapter Air discharge chamber Air Flexible duct Flexible duct discharge (dia. 200 mm) (dia. 150 mm) grille Canvas bellows Decorative panel Branch duct and air Intake panel (Features are explained on P. 37–38.) *1 *3 *3 *2 *3 *3 *1Applic able to R 71LU– R 125LU outdoor units (for temp. down to – 15°C ) (An option is required.) *2Applic able to R Y71LU– R Y125LU outdoor units (for temp. down to – 5°C ) *3Applic able to R (Y)71LU– 125LU outdoor units High-effic ienc y filter Option Others Interloc k c ontrol E xternal c ommand c ontrol C entral remote c ontrol C ontrol by 1 remote c ontroller Auto-c ooling/heating c hange-over C ontrol by 2 remote c ontrollers Auto-res tart Control features S elf-diagnos is func tion E mergenc y operation Low gas pres s ure detec tion Filter s ign Long-life filter Pre c harged for up to 30 m Work & Servicing Drain pump mec hanis m Timer s elec tor Year-round c ooling applic able Hot s tart Programme "Dry" S witc hable fan s peed Mould res is tant treatment for filter Mould prevention Comfort Feature Outdoor units P. 33–34 External static pressure is set to standard when the unit is shipped from the factory. A duct can be connected to the rear of the indoor unit to draw in outdoor air. * For dust concentration of 0.15 mg/m3 Cooling only Heat pump (Pa) (Custom installation required with locally procured materials) Long-life filter lasts about 1 year * Maintenance not required Model Rear intake blocking pad Air discharge opening flange Rear intake filter chamber Branch duct Low-draft filter chamber External static pressure pattern Note : Anec hoic c hamber c onvers ion value, meas ured ac c ording to J IS parameters and Features 460 mm or more 9 8 Quiet operation Indoor unit Ordinary duct (procured locally) Air conditioner 10 Air blow 45F 8 5 Programme "Dry" Switchable fan speed: High/Low Note: R emote c ontroller c able not inc luded. C ables must be proc ured loc ally. Air intake Long-life filter 3 Dehumidification is microprocessor controlled to prevent abrupt and uncomfortable changes in air temperature. BRC1C61 450 mm or more 4 6 PE fin Clever and compact mini ducted unit provides comfort and flexibility. Guide Line up P. 3–4, 7–8 1 Air intake Air blow 45 mm L-shaped space 21 3 22 WALL MOUNTED TYPE Sound level 43/ 37dB(A) WALL MOUNTED TYPE High Drastic size reduction Low FAY71L FAY Sound level 45/ 41 High Low Auto-swing Reduced size (by 22% in volume, 32% in installation area)makes installation possible in a very limited Conventional model space. FAY71LVE Cooling only FAY71LVE / FAY100FAVE Heat pump FAY71LVE / FAY100FAVE Improved airflow modes realise comfortable air distribution across the entire room Below features only apply to FAY71L. 5-level air direction setting 10° 10° 10° (FAY71FAVE) Auto-s wing from 10° to 70° -70 mm dB(A) -200 mm S ettable to 5 different levels between 10° to 70° 70° 290 mm FAY100FA Auto-air direction control 70° The air direction is set automatically to the memorised position of the previous air direction. (Initial setting is 10° for cooling 70° and 70° for heating.) Comfort even on the far side of the room To carry air to the far side of long rooms, extrahigh airflow adds 10% more fan speed the "high" setting. Air discharge strength is selected from the remote controller. 1,050 mm Made more compact, stylish, and quieter Sophisticated extension design FAY100FAVE Accessory required for indoor unit (option) Wired LCD remote controller Wireless LCD remote controller A s ignal rec eiver mus t be added to the indoor unit. Signal receiver unit (Installed type) Compact and stylish design that does not detract from the decor of the room. Two selectable temperature-sensors Flap is closed when not operating Easier to install and service Cooling only Light weight BRC7E619 Heat pump BRC7EA618 BRC1C61 FAY71L Cooling only BRC7C611W Heat pump Note: R emote c ontroller c able not inc luded. C ables must be proc ured loc ally. BRC7C610W FAY100F Wireles s remote c ontroller and s ignal rec eiver unit are s old as a s et. Reduced weight by 8kg greatly facilitates installation. Conventional New model (FAY71FAVE) (FAY71LVE) 21 Kg 13 Kg Easier to install and service Both indoor unit and wired remote controller (option) contain temperaturesensors. Temperature sensing can be set at the unit or, to further improve comfort level, closer to the target area at the wired remote control. Maintenance possible from the front of the unit All maintenance tasks can be carried out via front access. During service work, attachment and detachment of parts is easier. *Temperature-sensor on indoor unit must be used when the air c onditioner is c ontrolled from another room. **Wireles s remote c ontroller does not have a Low gas pressure detection Insufficient gas charging is normally hard to detect. During post-installation trials and regular inspection procedures, the refrigerant level is monitored by microprocessor to maintain proper gas pressure. Programme "Dry" Drain pump kit is available as option. Dehumidification is microprocessor controlled to prevent abrupt and uncomfortable changes in air temperature. Installs onto side of unit. Height of drain up Switchable fan speed: High/Low 1,000 mm Indoor unit Drain-pump kit (Available to be installed onto right side.) Drain enclosure can be used on either left and right side. Drain pan and air filter can be kept clean by mould-proof polystyrene Removable and washable grille DIII-NET connection is standard specification. Adapter is not required. (Features are explained on P. 37–38.) Cooling only Heat pump 23 Guide Line up P. 3–4, 7–8 Outdoor units P. 33–34 Remote controllers P. 35–36 Standard specifications P. 41, 51 Options P. 58 Outer dimension drawings P. 62, 63 *1Applic able *2Applic able *3Applic able *4Applic able *1 *2 *4 *4 *1 *3 *4 *4 PE fin Others Interloc k c ontrol C entral remote c ontrol E xternal c ommand c ontrol C ontrol by 2 remote c ontrollers C ontrol by 1 remote c ontroller Auto-c ooling/heating c hange-over Auto-res tart Control features S elf-diagnos is func tion E mergenc y operation Low gas pres s ure detec tion Filter s ign Pre c harged for up to 30 m Work & Servicing Drain pump mec hanis m Mould-proofing drain pan Mould res is tant treatment for filter Timer s elec tor Year-round c ooling applic able Hot s tart Upward Two s elec table temperature-s ens ors Programme "Dry" S witc hable fan s peed Draft prevention func tion Auto s wing Model Mould prevention Comfort Feature High fan s peed mode Features when wired remote c ontroller is us ed to R 71LU/R 100LU outdoor units (for temp. down to – 15°C ) (An option is required.) to R Y71LU/R Y100LU outdoor units (for temp. down to – 5°C ) to R (Y)71LU/100LU outdoor units 24 FLOOR STANDING TYPE Sound level FLOOR STANDING TYPE 41/ 35 High Low Quiet operation dB(A) Easier to install and service dB(A) FVY71LA FVY Indoor unit High Low 71LA 41 46 49 35 40 43 100LA 125LA Lightweight The unit can be easily transported and installed. Note : Anec hoic c hamber c onvers ion value, meas ured ac c ording to J IS parameters and Weight Auto-swing delivers comfort to every corner of the room Cooling only FVY71LAVE–125LAVE Heat pump FVY71LAVE–125LAVE The floor-standing configuration means the FVY is easy to install and maintain. It can also be installed under high ceilings. Conventional FVY-F New model 71 class 45 kg 63 kg 67 kg 39 kg 46 kg 47 kg 100 class FVY units have swinging louver spreads comfortable airflow. Any uncomfortable sensation of sudden change is avoided by a slow cycle of 2 to 3 full swings per minute. 125 class Manual setting of vertical airflow louvers Auto-swing Indoor unit Long-life filter lasts about 1 year * Maintenance not required *For dust concentration of 0.15 mg/m3 LCD control panel is standard Filter exchange interval Vertical airflow adjustment is possible when (changing between cooling and heating or) to match interior spaces and partitions. Note: This remote controller has a temperaturesensor. A good choice for spaces with ceilings so high that heating by ceiling-mounted units is inefficient. Annual Long-life filter Low gas pressure detection Insufficient gas charging is normally hard to detect. During post-installation trials and regular inspection procedures, the refrigerant level is monitored by microprocessor to maintain proper gas pressure. Programme "Dry" Dehumidification is microprocessor controlled to prevent abrupt and uncomfortable changes in air temperature. Note: For optimal installation, space factors should be accurately calculated. 2 weeks Conventional filter Switchable fan speed: High/Low Easy-to-operate, handy LCD control panel The LCD displays text, numbers and graphics to indicate the temperature setting, timer setting, auto-swing, fan speed, and more. Furthermore, the LCD panel can be detached and used as a remote controller, so air conditioning can be controlled from another room or from the cash register. (Remote controller cable not included. Cables must be procured locally.) Two selectable temperature-sensors Temperature-sensors on both indoor unit and wired remote controller. Temperature sensing can be set closer to the target area to further improve comfort level. *Temperature-sensor on indoor unit must be used when the air c onditioner is c ontrolled from another room. **Wireles s remote c ontroller does not have a temperature-s ens or. (Features are explained on P. 37–38.) Cooling only Heat pump 25 Guide Existing Line up models: P.33–4, P. ~ 4 7–8 Outdoor units units: P.25 P. 33–34 ~ 26 Remote controllers controllers: P.27 P. 35–36 ~ 28 Standard specifications specifications: P.34 P. 42, 52 Options Outer dimension drawings Options: drawings: P.36 P. 58~ 37 P. P.38 63~ 45 *1 *3 *3 *2 *3 *3 *1Applic able to R 71LU– R 125LU outdoor units (for temp. down to – 15°C ) (An option is required.) *2Applic able to R Y71LU– R Y125LU outdoor units (for temp. down to – 5°C ) *3Applic able to R (Y)71LU– 125LU outdoor units PE fin Others Interloc k c ontrol C entral remote c ontrol E xternal c ommand c ontrol C ontrol by 1 remote c ontroller C ontrol by 2 remote c ontrollers Auto-c ooling/heating c hange-over Auto-res tart Control features S elf-diagnos is func tion E mergenc y operation Low gas pres s ure detec tion Filter s ign Long-life filter Work & Servicing Pre c harged for up to 30 m Mould res is tant treatment for filter Timer s elec tor Two s elec table temperature-s ens ors Year-round c ooling applic able Hot s tart S witc hable fan s peed Auto s wing Model Mould prevention Comfort Feature Programme "Dry" Features 26 DUCT CONNECTION MIDDLE STATIC PRESSURE TYPE Sound level DUCT CONNECTION MIDDLE STATIC PRESSURE TYPE 39dB(A) Freedom of layout (220V) High LOW FDMG71A 42 44 45 46 47 38 36 37 36 37 FDMG125A FDMG140A Duct connection is simpler with standard rear intake chambers FDMG180A FDYM03FA FDYM03FAV1–06FAV1 FDYM03FAV1–06FAV1 FDYM04FA Compact, 295 mm high design makes installation possible where the ceiling space is limited (For FDYM) FDYM05FA FDYM06FA FDYM03FA Unit can be mounted in the ceiling and air can be delivered freely by duct. Indoor unit FDMG100A Middle static pressure type is available in a larger than standard space FDMG100A Cooling only FDMG71AV1–180AV1 Heat pump dB(A) (220V) The duct system allows the efficient location of discharge outlets in accordance with the room layout High FDYM03FA FDMG/FDYM Quiet operation Note : Anec hoic c hamber c onvers ion value, meas ured ac c ording to J IS parameters and Air conditioner 295 mm Ordinary duct (procured locally) Ordinary duct (procured locally) Accessory required for indoor unit (option) For FDYM Wired LCD remote controller Wireless LCD remote controller Switchable fan speed: High/Low 305 mm or more Air intake Air blow 39 39 44 46 Programme "Dry" Dehumidification is microprocessor controlled to prevent abrupt and uncomfortable changes in air temperature. BRC1C61 Note: R emote c ontroller c able not inc luded. C ables must be proc ured loc ally. Signal receiver unit (Separate type) Cooling only BRC4C64 Heat pump BRC4C62 For FDMG Digital remote controller Wireles s remote c ontroller and s ignal rec eiver unit are s old as a s et. Remote controller KRC47-2A KRC47-4A Low gas pressure detection Insufficient gas charging is normally hard to detect. During post-installation trials and regular inspection procedures, the refrigerant level is monitored by microprocessor to maintain proper gas pressure. Supports simultaneous running of the twin and triple multi operations. Twin Multi Operation Triple Multi Operation KRC47-1A See pages 31–32 for details of the Multi Series. Simultaneous air conditioning of two rooms and ventilation grille (ventilation opening) When air conditioning two rooms simultaneously, the air discharged into each room must be circulated back to the air conditioner. To achieve this, a ventilation duct should be installed for each room or one of the indicated ventilation grilles should be installed on the partitioning wall or under the door between the rooms. 27 Guide Line up P. 3–10 Outdoor units P. 33–34 Remote controllers P. 35–36 Standard specifications P. 43, 48, 53, 56 Options P. 59 Outer dimension drawings P. 64, 65 Under-door cutout Ventilates air through the partitioning wall. (S ee right) Partitioning wall Ventilation grille Ventilation grille Under-door c utout Note: The under-door cutout method should be used only when there is a small volume of airflow. Adjus table external s tatic pres s ure PE fin Twin and triple multi operation Others Interloc k c ontrol E xternal c ommand c ontrol C entral remote c ontrol G roup c ontrol by 1 remote c ontroller C ontrol by 2 remote c ontrollers *3 Control features Auto-res tart *3 *3 S elf-diagnos is func tion *3 *2 E mergenc y operation *1 Timer s elec tor Low gas pres s ure detec tion Year-round c ooling applic able Work & Servicing Pre c harged for up to 30 m Heat pump FDMG FDYM Programme "Dry" S witc hable fan s peed Model Automatic c ool/heat c hange -over Comfort Feature Cooling only Wall-installed ventilation grille (Features are explained on P. 37–38.) Hot s tart Features Door-installed ventilation grille *1Applic able to R 71LU– R 140LU outdoor units (for temp. down to – 15°C ) (An option is required.) *2Applic able to R Y71LU– R Y140LU outdoor units (for temp. down to – 5°C ) and R Y200LU– R Y250LU outdoor units (for temp. down to – 0°C ) *3Applic able to R (Y)71LU– 140LU outdoor units 28 Sound level Sound level DUCT CONNECTION LOW STATIC PRESSURE TYPE DUCT CONNECTION HIGH STATIC PRESSURE TYPE 38 dB(A) LOW FDBG/FDYB FD( Y) FDYB50KA (220V) FDYB50KA Cooling only FDBG25AVE–71AVE Heat pump FDYB35KAVE–71KAVE Accessory required for indoor unit (option) 51 dB(A) High FDY06KA FDY06KA Cooling only FD03KY1–20KY1 Heat pump FDY06KAY1–20KAY1 Accessory required for indoor unit (option) Cooling only Cooling only Digital remote controller Remote controller Remote controller KRC47-2A KRC47-4A KRC47-1A KRC47-3A Heat pump Heat pump Wired LCD remote controller Wired LCD remote controller Signal receiver unit (Separate type) BRC1C61 Note: R emote c ontroller c able not inc luded. C ables must be proc ured loc ally. BRC4C62 Note : Anechoic chamber conversion value, measured according to J IS parameters and criteria. Highly durable outdoor unit has PE fins for improved resistance to salt corrosion and atmospheric pollution. Durable S uc tion c hamber 29 Adjus table external s tatic pres s ure PE fin Triple and double twin multi operation *2 * Applic able to R Y71LU outdoor units (for temp. down to – 5°C ) and R Y200LU– R Y250LU outdoor units (for temp. down to – 0°C ) *2Applic able to R Y71LU outdoor units Guide Line up P. 3–10 *2 Outdoor units P. 33–34 Remote controllers P. 35–36 Adjus table external s tatic pres s ure PE fin Simultaneous air conditioning of two rooms and ventilation grille (ventilation opening) 1 *1 Others *2Applic able to R (Y)140LU outdoor units *3R equired to c hange the pulley *4FDY06-10 only Others Interloc k c ontrol C entral remote c ontrol G roup c ontrol by 1 remote c ontroller E xternal c ommand c ontrol C ontrol by 2 remote c ontrollers Control features Auto-res tart S elf-diagnos is func tion E mergenc y operation Low gas pres s ure detec tion Pre c harged for up to 30 m Timer s elec tor Work & Servicing Year-round c ooling applic able Automatic c ool/heat c hange -over Programme "Dry" S witc hable fan s peed Hot s tart Comfort Control features Interloc k c ontrol Hot s tart (Features are explained on P. 37–38.) Feature Cooling only Heat pump See pages 31–32 for details of the Multi Series. Work & Servicing C entral remote c ontrol Double twin Multi Operation Guide Line up P. 3–4, 7–8 Outdoor units P. 33–34 Remote controllers P. 35–36 Standard specifications P. 44, 45, 53 Model Options *3 Cooling only P. 59 *4 *1 *2 *2 *4 *3 Heat pump Outer dimension drawings *1Applic able to R Y140LU outdoor units (for temp. down to – 5°C ) and R Y200LU– R Y250LU outdoor units (for temp. downP. to 65–67 – 0°C ) Comfort Feature G roup c ontrol by 1 remote c ontroller E xternal c ommand c ontrol Triple Multi Operation (Features are explained on P. 37–38.) C ontrol by 2 remote c ontrollers To prevent increased operation sound, avoid installing the air suction grille directly below the suction chamber. Auto-res tart [Duc t c onnec tion] Supports simultaneous running of the triple and double twin multi operations. Model Features Air filter S elf-diagnos is func tion To achieve increased durability by improved resistance to salt corrosion and atmospheric pollution, coated PE fins (with special acryl pretreatment) are used for the heat exchanger of the outdoor unit. Features Many options are available for use with large-scale and advanced-function centrally controlled systems Durable E mergenc y operation 39 BRC4C62 Wireles s remote c ontroller and s ignal rec eiver unit are s old as a s et. Central control Low gas pres s ure detec tion 42 Quiet operation Pre c harged for up to 30 m FDBG60AVE Small, lightweight, and easy-to-install outdoor unit. Timer s elec tor Low Year-round c ooling applic able High Automatic c ool/heat c hange -over Indoor unit Note: R emote c ontroller c able not inc luded. C ables must be proc ured loc ally. Recommended for spacious and large-volume areas because of its flexible installation Suitable for large stores, factories, and other large areas, and for use with housing ducts in homes Compact dB(A) Signal receiver unit (Separate type) BRC1C61 Wireles s remote c ontroller and s ignal rec eiver unit are s old as a s et. Ideal for quiet, beautiful living spaces Suitable for condominiums and apartments, houses and hotels Quiet operation Wireless LCD remote controller Wireless LCD remote controller Standard specifications P. 42, 52, 56 Options P. 59 Outer dimension drawings P. 64 When air conditioning two rooms simultaneously, the air discharged into each room must be circulated back to the air conditioner. To achieve this, a ventilation duct should be installed for each room or one of the indicate ventilation grilles should be installed on the partitioning wall or under the door between the rooms. Door-installed ventilation grille Partitioning wall Wall-installed ventilation grille Under-door cutout Ventilates air through the partitioning wall. (S ee right) Ventilation grille Ventilation grille Under-door c utout Note: The under-door cutout method should be used only when there is a small volume of airflow. 30 Simultaneous operation system MULTI SERIES Simultaneous operation system Remote controllers for the Multi Series MULTI SERIES INDOOR UNIT Wired LCD remote controller Wireless LCD remote controller (Option) (Option) Twin, Triple, and Double Twin Multi-Operation CEILING MOUNTED CASSETTE TYPE Heat pump BRC7EA66 BRC7E63W Heat pump BRC4C62 Cooling only BRC4C64 BRC4C62 Cooling only BRC1C61 DUCT CONNECTION LOW STATIC PRESSURE TYPE DUCT CONNECTION MIDDLE STATIC PRESSURE TYPE In a single-floor restaurant, for example, positioning 4 units at strategic locations realises comfortable airflow that reaches every inch of the room. In large interior spaces a single indoor unit may not be able to provide uniform comfort. Installation of 2 to 4 units, can provide an effective solution. Heat pump CEILING SUSPENDED TYPE Simultaneously operates 2 to 4 indoor units using a single outdoor unit. BRC7C613W BRC7C612W Cooling only Heat pump A single remote controller controls simultaneous operation of multiple indoor units. Connect the wired remote controller to turn an indoor unit into the master unit. Install the signal receiver unit (part of the optional wireless remote controller) to turn an indoor unit into the master unit. Supports Two selectable temperature-sensor functions. Wired remote controller has a temperature-sensor. Depending on the installation conditions, select and set the temperature-sensor of a selected indoor unit or the temperaturesensor of the remote controller. Because the wireless remote controller does not have a temperature-sensor, select the temperature-sensor of the indoor master unit. Note: This type of system does not allow individual control or independent operation of indoor units. It is not the best choice for large rooms with partitions. Installing multiple units is economical and realises comfort Lower cost of installation than for individual pair type Reduced installation space for outdoor units Enhanced comfort from distributed indoor units Note: Selectable temperature sensing is available with ceiling-mounted cassette and ceilingsuspended models, but not with middle staticpressure models. Note: An indoor unit's temperature-sensor must be used when the air conditioners are controlled from another room. Indoor units include ceiling mounted cassette type, ceiling suspended type, and duct connection middle and low static pressure type. Double Twin Multi operation 4 indoor units can be run simultaneously with a single outdoor unit. Improved comfort level and space-saving for outdoor unit installation New 5 HP x 2 units 10 HP double twin multi operation Twin Multi Operation Triple Multi Operation Sub unit Dead zone Dead zone Before Piping Guideline Branch piping kit L1 Branch piping kit Branch piping kit Required about 40% less installation space for outdoor unit Before Sub unit L2 Branch piping kit Sub unit Main unit L3 L3 Outdoor unit L4 Sub unit L5 L1 Branch piping kit Remote controller Main pipe L Sub unit L6 L2 Remote controller Main pipe L Outdoor unit Outdoor unit 300 mm R(Y)200KU or R(Y)250KU x 1 unit 500 mm Simultaneous operation system Max. piping length Max. branch piping length 300 mm 1000 mm Max. branch pipe length difference Twin Multi Operation L Max. (L1, L2) Max. (L1, L2)*1 Max. (L1, L2) 50 m 20 m Min. (L1, L2)*2 Triple Multi Operation Double Twin Multi Operation L L Max. (L1, L2, L3) Max. (L1, L2 , L3) 10 m Max. (L1, L2, L3) 50 m 20 m Min. (L1, L2, L3) 10 m Max. (L1, L2) Max. (L3, L4, L5, L6) Max. (L1, L2) Max. (L3, L4, L5, L6) (L2 L6) (L1 L3) 10 m L2 L1 10 m L4 L3 10 m L6 L5 10 m In case of L1 Triple Multi operation Main unit New R(Y)125KU x 2 units 4 indoor units distribute comfortable airflow throughout the room. Simultaneous operation of four indoor units can be controlled from a single remote controller. Requires a single refrigerant piping system. L1 Remote controller Main pipe L Branch piping kit Sub unit Main unit L2 Double Twin Multi Operation Twin Multi operation L2, L3 Max. level difference between outdoor unit and indoor units 30 m 30 m 30 m Max. level difference between indoor units 0.5 m 0.5 m 0.5 m L4, L5 50 m 20 m L6 *1 Max. (L1, L2) means maximum length out of L1 and L2. *2 Min. (L1, L2) means minimum length out of L1 and L2. Refrigerant piping uses terminal branching to facilitate installation. (Branch piping kits are sold separately. Please use the model indicated on page 59) Branch piping kit Branch piping kit 31 Guide Line up P. 5–6, 9–10 Outdoor units P. 33–34 Remote controllers P. 35–36 Standard specifications P. 46–48, 54–56 Options Outer dimension drawings P. 57–59 P. 60–74 (For Twin Multi) (For Triple Multi) (For Double Twin Multi) 32 OUTDOOR UNIT OUTDOOR UNIT Compact unit provides quiet operation. P o w e r fu l Ins ta lla tion a nd ma intena nc e Uses "Receiver" to enhance refrigerant control Pre charged for up to 30 metres (Applies to R(Y)71LU–140LU) Instead of the using an accumulator to absorb excess refrigerant, Daikin outdoor units have a receiver in the piping located away from the compressor. By preventing the return of liquid to the compressor, the receiver enhances reliability. Defrost control delivers powerful heating in extremely cold climates (Applies to RY71LU–140LU) (Heat pump only) R(Y)125LU R(Y)140LU Q u ie t O pe r a t io n Fitted with wide inlet fan Fitted with Super Aero Grille (Applies to R(Y)71LU–140LU) (Applies to R(Y)71LU–140LU) Fully shaped aerodynamic propellers are designed to push air with a large wing surface, providing both high blow volume and quiet operation with turbulence. To suppress turbulence and achieve quiet operation, the curved ribs of the grille are optimised to meet the outflow of air. Equipped with scroll compressor for quiet operation (Applies to R(Y)125LU and 140LU) Smooth running, minimal vibration, low operating sound. Integral heating capacity and temperature difference (actual measurement when outdoor temperature is -1.5°C) 25 °C Defrost begins in this area Integral heating capacity 20 15 10 5 Max. point of integral capacity R(Y)100LU Defrost and hot start R(Y)71LU To optimise heating performance, by monitoring the difference in air temperature in the indoor/outdoor heat exchanger and the intake air temperature, the system accurately adjusts to provide the best operating parameters. This enables defrost mode to be initiated and so minimise indoor declines in temperature caused by frost. For example, if the outdoor airtemperature falls to -1.5°C, the integrated heating capacity is raised about 20%. 0 0 10 20 30 Difference between indoor heat exchange temperature and intake air temperature ( T) 40 50 60 70 80 Elapses operation time (min.) Defrost operation complete Defrost monitoring start (heating operation restart) (monitors to maximum point) Suited for year-round cooling applications Wide inlet fan Operation sound (Applies to R(Y)71LU–140LU) dB(A) Heat pump Outdoor unit Sound level (cool/heating) RY71LU 48/49 Slim and low-profile design outdoor units RY100LU 49/52 (Applies to R(Y)71LU–140LU) RY125LU 49/52 RY140LU 54/56 Cooling only Outdoor unit Sound level R71LU 48 (Applies to R(Y)71LU-125LU) R100LU 49 The light weight makes delivery and installation easier. R125LU 49 R140LU 54 C o m pa c t Compactly designed outdoor unit with interior layout optimised for the smooth airflow. Reduced weight conventional New 108 kg 89 kg RY100KUV1 RY100LUV1 The design curved Super Aero Grille restricts the spread of exhaust gas and fits in the same space as conventional outdoor units. 50 500 (mm) 33 Note : Anec hoic c hamber c onvers ion value, meas ured ac c ording to J IS parameters and Cooling is efficient even in winter when indoor temperatures are higher than those outside, such as in underground public spaces or offices with many computers. If refrigerant piping length does not exceed 30 m, there is no need for onsite gas charging. (Applies to R(Y)71LU–140LU) Flexible design for large room or multi-use Allowed refrigerant pipe length and level difference Pre charged *1 Max. length Max. level difference R25J 10 m 25 m 15 m RY35F 10 m 20 m 15 m R35J RY50GA R50G RY60GA R60G RY71LU R71LU RY100LU R100LU RY125LU R125LU RY140LU R140LU RG71A RA140A RG180A R100FU R125FU 10 m 25 m 15 m 10 m 30 m 15 m 5m 30 m 15 m 30 m 50 m 30 m 50 m 30 m 50 m 30 m 50 m 30 m 50 m 30 m 50 m 30 m 30 m 30 m (Equivalent length 70 m) (Equivalent length 70 m) (Equivalent length 70 m) 30 m (Equivalent length 70 m) 5m (Equivalent length 70 m) 5m (Equivalent length 70 m) Piping can be drawn out from three directions - front, left side, or below. 200 and 250 class models can be combined for centralised, horizontal-series installation 1 Note: Additional refrigerant charging is required if the refrigerant pipe is longer than the length. Common width and depth make series installation easy. 4-direction piping offers greater layout freedom R(Y)200KU R(Y)200KU R(Y)250KU (Applies to R(Y)71LU–140LU) Piping can be run from the front, bottom, right or rear surface according to how the unit is installed. 690 mm 1280 mm 1280 mm 1280 mm Allowed refrigerant pipe length and level difference Facilitates pump down (Refrigerant recovery function) A pump-down switch is provided to make it easier to collect refrigerant if the unit is to be moved or layout modified. Pre charged *1 Max. length Max. level difference 5m 50 m 30 m 50 m 30 m R(Y)200KU R(Y)250KU 5m (Equivalent length 70 m) (Equivalent length 70 m) Note: 1Additional refrigerant charging is required if the refrigerant pipe is longer than the length. Also adapts to year-round cooling Low gas level detection function (Applies to R(Y)71LU–140LU) Effective gas monitoring reduces the labor required for operation, maintenance, and repairs. RY200K U and250KU can adapt up to 0°C. (Heat pump only) RU08/10K models are available in two type depending on installation conditions • Heat pump/RY71–140LU: possible up to -5°C • Cooling only/R71–140LU: possible up to -15°C • The year-round cooling kit is required as option. RU08/10KU models are factory shipped with refrigerant charged for 5 m of piping. RU08/10K models are factory shipped with no refrigerant charged. D u r a bilit y Heat exchange fins provided with anti-corrosion treatment To achieve increased durability by improved resistance to salt corrosion and atmospheric pollution, coated PE fins (with special acryl pretreatment) are used for the heat exchanger of the outdoor unit. (Applies to all outdoor units) Construction Non-treated fin Aluminium PE fin Hydrophilic film Aluminium C orrosion resistant ac rylic resin 34 LCD REMOTE CONTROLLER Easy-to-read LCD remote controller allows various system control configurations and can control multiple indoor units. LCD REMOTE CONTROLLERS Necessary optional accessory Remote controller options are shown on the page introducing each indoor unit model. Wired LCD remote controller W ir e d r e m o t e c o n t r o lle r h a s bu ilt -in t e m pe r a t u r e -s e n s o r (Applies to wired remote controllers) Easier to read because LCD screen is larger. For easier operation, louver switches, which are frequently used, have been made larger. Oil-resistant plastic casing. Only 17 mm thick. Can be installed either recessed or exposed. Indoor units applicable for the remote controller CEILING MOUNTED CASSETTE TYPE CEILING SUSPENDED TYPE CEILING SUSPENDED CASSETTE TYPE CEILING MOUNTED CASSETTE CORNER TYPE WALL MOUNTED TYPE CEILING MOUNTED BUILT-IN TYPE*1 DUCT CONNECTION LOW STATIC PRESSURE TYPE *2 DUCT CONNECTION MIDDLE STATIC PRESSURE TYPE DUCT CONNECTION HIGH STATIC PRESSURE TYPE *2 BRC1C61 BRC1C61 *1. When the auto-swing function is not available, the message, THIS FUNCTION IS NOT AVAILABLE is displayed when the wind direction adjustment button is pressed. *2. Applicable to only heat pump type. Wired LCD remote controller with weekly schedule timer Remote control is equipped with weekly timer function. 24-hour clock function (1-hour backup for power failures) Programming function for each day of week. Scheduling possible of start/stop and temperature limit (5 settings/day) Programming can be enabled or disabled. Copy function for programmed schedules. Indoor units applicable for the remote controller CEILING MOUNTED CASSETTE TYPE CEILING SUSPENDED TYPE CEILING SUSPENDED CASSETTE TYPE CEILING MOUNTED CASSETTE CORNER TYPE WALL MOUNTED TYPE CEILING MOUNTED BUILT-IN TYPE*1 DUCT CONNECTION LOW STATIC PRESSURE TYPE *2 DUCT CONNECTION MIDDLE STATIC PRESSURE TYPE DUCT CONNECTION HIGH STATIC PRESSURE TYPE *2 BRC1D61 BRC1D61 *1. When the auto-swing function is not available, the message, THIS FUNCTION IS NOT AVAILABLE is displayed when the wind direction adjustment button is pressed. *2. Applicable to only heat pump type. •Standard remote controller (BRC1C61) is not required. •If the BRC1D61 is connected to the centralised remote controller, the schedule function is not available. Wireless LCD remote controller signal receiver mounted type The wireless remote controller is supplied in a set with a signal receiver. Shape of signal receiver unit differs according to the indoor unit. Note: The signal rec eiver unit shown in the photograph is for mounting inside the dec oration panel of the c eiling mounted assette type. Indoor cunits applicable for the remote controller Signal receiver unit (For ceiling mounted cassette type) Wireless remote controller 35 Enables temperature sensing closer to target area for improved comfort. (When using remote control from another room, temperature-sensor in indoor unit's air inlet must be selected.) Note: The indoor unit’s temperature-sensor is specified at the time of shipment. Temperature sensing with the wired remote controller is not available with the ceiling mounted cassette corner, ceiling-mounted built-in, and duct connection type. L C D pa n e l s h o w s o pe r a t in g s t a t u s in le t t e r s , n u m be r s , a n d m o t io n . Airflow / swing display (Not available for ceiling mounted built-in type and duct connection type ) Preset temperature / operation mode display Programming time display Self-diagnosis function Setting contents: High ceiling use, air direction, filter type, address for centralised control (group control address is set automatically). Control by 1 remote controller Wired remote controller Wireless remote controller (Basic system) Non-polar, double-c ore (max. wiring length 500 m) Control by 2 remote controllers Group control S ignal rec eiver unit ins talled on indoor unit C ontrol by 1 wireles s remote c ontroller and 1 wired remote c ontroller (S ee note 1) For control from 2 locations such as in room and control room, exits, etc. S ignal rec eiver unit ins talled on indoor unit C onnec ts 2 wired remote c ontrollers For simultaneous control of up to 16 indoor units. Automatic addres s s etting func tion Automatic addres s s etting func tion S ignal rec eiver unit ins talled on 1 indoor unit Control by external command Operation and surveillance is carried out using the contact signal from the operation control box in the building surveillance (security) room. (C ommand from outs ide) (C ommand from outs ide) Optional wiring adaptor for elec tric al appendic es is nec es s ary Optional wiring adaptor for elec tric al appendic es is nec es s ary C entral remote c ontroller (option) Centralised remote control Remote controller is equipped with model name and failure display functions. This facilitates service in the unlikely event of a malfunction. S k y A ir s h a r e s c o m m o n c o n t r o l w it h H R V (h e a t r e c la im v e n t ila t io n ) a n d t h e o t h e r D a ik in a ir -c o n dit io n in g u n it s , t h u s s im plify in g in t e r lo c k in g o pe r a t io n s . Operation start and stop time can be set for individual timers up to 72 hours. The liquid crystal display also shows when it is time to clean the filter, when changeover is under centralised control, and ventilation/cleaning. Monitors operating status within the system covering 40 items, and displays a message to indicate as soon as a malfunction occurs. Control pattern F a c ilit a t e s m a in t e n a n c e a n d r e pa ir All initial settings can be set from the remote controller. After interior construction is complete, ceiling mounted units can be remotely set without having to use stepladder access for manual setting. Displays preset room temperature and operating status (fan, dry, cool). S im ple s y s t e m pr o v id e s a d iv e r s e a s s o r t m e n t o f c o n t r o l m o d e s . N o n -po la r , do u ble -c o r e c o n n e c t io n s pe c ific a t io n s s im plify w ir in g Non-polar, double-core remote controller wire prevents wiring mistakes. signal receiver unit (or decoration panel) of wireless type is also easy to connect. Displays auto-swing operating status and setting position of air discharge angle. C entral remote c ontroller (option) Centralised control of up to 64 indoor groups from remote location up to 1 kilometer away. Optional S kyAir s eries interfac e adaptor required. *1 Optional S kyAir s eries interfac e adaptor required. *1 HR V Link by remote controller group control. HR V C an be operated s imultaneous ly or independently by remote c ontroller (s et by ventilation mode) Interlock control with HRV C an be operated s imultaneous ly by remote c ontroller (s et by ventilation mode) C entral remote c ontroller (option) C entral remote c ontroller (option) Easily adaptable to large-scale, highfunction, centralised remote control systems. Zone link control by centralised control. Installing and connecting control wiring between SkyAir and other Daikin air-conditioning equipment is easy. HR V HR V HR V for indoor units within a zone are operated by interlocking C an also be operated independently by remote controller. Optional interface adaptor for S kyAir series is necessary *1 Optional adaptor for external commands or remote control of external equipment has been standardised to one type. HR V for indoor units within a zone are operated by interloc king Optional interfac e adaptor for S kyAir s eries is nec es s ary *1 Note: When a wireless remote c ontroller is used, remote c ontrol by two remote c ontrollers is not possible. *1. DIII-net adaptor function is standard equipment for the FAY71L. Easily adaptable to large-scale, high-function, centralised remote control system. C e ntr a l r e m o te c o ntr o lle r DCS302CA61 (Option) U n ifie d o n /o ff c o n t r o lle r DCS301BA61 (Option) S c h e d u le t im e r DST301BA61 (Option) DCS601C51 (Option) Signal receiver unit is contained inside decoration panel or indoor unit Heat pump Cooling only CEILING MOUNTED CASSETTE TYPE BRC7C612W BRC7C613W CEILING SUSPENDED TYPE BRC7E63W CEILING SUSPENDED CASSETTE TYPE FAY71L WALL MOUNTED TYPE FAY100FA DUCT CONNECTION LOW STATIC PRESSURE TYPE DUCT CONNECTION MIDDLE STATIC PRESSURE TYPE DUCT CONNECTION HIGH STATIC PRESSURE TYPE BRC7EA66 BRC7C528W BRC7C529W BRC7EA618 BRC7E619 BRC7C610W BRC7C611W BRC4C62 Centralised control of on/off by group or all at once for up to 256 indoor units. Unified control of weekly schedule for up to 1,024 indoor units. Schedule timer sets on/off time in 1 minute units to be executed twice a day for a week at a time. With its high functionality, the full color “all-in-one” graphic controller facilitates management of Skyair System in a variety of ways. *Please refer to the page 59 for the details. BRC4C62 BRC4C62 Centralised control, with setting as simple as it is with a standard remote controller, of up to 64 groups (1,024 indoor units) is possible. BRC4C64 Interface adaptor for SkyAir series Enables centralised control via connection to a high-speed, DIII-NET communication system, adopted for the Daikin VRV system. Necessary for interface adaptor for SkyAir series with the central remote control units shown at above. Note : DIII-net adaptor function is standard equipment for the FAY71L. DTA102A52 (Option) Central control adaptor kit *2 DTA107A55 (Option) (for FD series) *2.The central control adaptor kit for FDB series can be made to order. 36 Abundance of functions that provide comfortable air-conditioning in stores and offices. Note: Some features only available on selected models. See model pages for full list of features applicable to each unit. C omfort A u t o -s w in g H ig h fa n s pe e d m o d e Delivers comfortable air-conditioning to all areas, near to and far from the air-conditioner. You can increase fan speed approximately 10% higher than the "high" setting. Applicable for wall mounted type H ig h -c e ilin g a pplic a t io n Air discharge direction angle can be set (fixed setting) S w in g pa t t e r n s e le c t io n Delivers air-conditioning comfort all the way down to the floor in air-conditioning zones with high ceilings. W ork a nd S e rvic ing L o w g a s pr e s s u r e d e t e c t io n D r a in pu m p m e c h a n is m Steeper gradient realises more efficient condensate drainage. High-lift is especially useful for long lengths of drain piping. P r e c h a r g e d fo r u p t o 3 0 m e t r e s If refrigerant piping length does not exceed 30 m, there is no need for on-site gas charging. If there is a malfunction elsewhere in the system, the fan or compressor can still be operated. L o n g -life filt e r Maintenance is not required for one year (two years when a ceiling mounted cassette type is used). C e ilin g s o ilin g pr e v e n t io n fu n c t io n Applicable for ceiling mounted cassette type and ceiling mounted cassette corner type. Note:When units are installed on high ceilings, depending on the model, various restrictions concerning maximum height, air discharge direction, and choice of options may apply. (1) Air direction in standard position T w o s e le c t a ble t e m pe r a t u r e -s e n s o r s (2) Air direction in draft prevention position Temperature-sensors are included in the indoor unit and optional wired remote controller. Temperature sensing closer to target area is possible to further (3) Air direction in ceiling soiling prevention position D r a ft pr e v e n t io n fu n c t io n Daikin's innovative air discharge mechanism keeps airflow away from the ceiling. Ceiling cleaning is less frequently required. F ilt e r s ig n To prevent cold air drafts, automatically adjusts airflow to horizontal vector when heating initially starts or when the thermostat turns off. (Horizontal air dis c harge) Note: Wireless remote controllers have no temperature-sensor. H ot s ta rt (after defrost) Uncomfortable cold air draft is not discharged when heating operation starts or when switching to heat after defrosting. Y e a r -r o u n d c o o lin g a pplic a ble S w it c h a ble fa n s pe e d High setting provides maximum reach while low setting minimises drafts. P rogra m m e " Dry" Dehumidification is microprocessor controlled to prevent uncomfortable changes in air temperature. Useful for reducing uncomfortable humidity without uncomfortable cooling. Efficient cooling even in winter when indoor temperatures are higher than those outside, such as in underground public spaces or offices with many computers. • Heat pump/RY71—140LU: possible up to -5°C • Cooling only/R71—140LU: possible up to -15°C • The year-round cooling kit is required as option. T im e r s e le c t o r Operation starts when the preset time of the ON timer elapses and stops when the preset time of the OFF timer elapses. S e lf d ia g n o s is fu n c t io n The operating parameters of indoor and outdoor units, and sensor data at critical locations throughout the system, are constantly monitored using a microcomputer. To facilitate quick response in the event of a malfunction, a message appears on the LCD of the remote controller and an LED on the unit illuminates. The filter sign warns you when it is time to clean the filter. *When using a wired remote controller the sign is displayed in the LCD. When using a wireless remote controller the filter sign lamp illuminates on the signal receiver unit. C ontrol features Use the temperature-sensor in the indoor unit when controlling air conditioning from another room. (heating) E m e r g e n c y o pe r a t io n (Applies to R(Y)71LU–140LU) (draft prevention, standard, ceiling soiling prevention) You can freely set 3 air discharge positions by remote controller. Insufficient gas charging is normally hard to detect. During post-installation trials and regular inspection procedures, the refrigerant level is monitored by microprocessor to maintain proper gas pressure.Reliability is assured and maintenance and inspection can be carried out more quickly. A u t o -r e s t a r t C o n t r o l by 1 r e m o t e c o n t r o lle r If there is a power outage while the equipment is operating, operations will restart in the same mode as before the power cut when electricity is restored. A u t o c o o l/h e a t c h a n g e -o v e r (Heat pump only) Detects difference in preset temperature and actual room temperature and automatically switches to cooling or heating accordingly. C o n t r o l by 2 r e m o t e c o n t r o lle r s You can turn up to 16 indoor units on/off with a single remote controller. (When using connected indoor units, the settings must all be the same and on/off will be simultaneous.) E x te rna l c om m a nd c ontrol Operation and surveillance is carried out using the contact signal from the operation control box in the building surveillance (security) room. C e ntra l re m ote c ontrol Using 2 remote controllers you can operate the equipment locally or from a remote location. Note: When a wireless remote controller is used, remote control by two remote controllers is not possible. Optional central remote controller enables centralised control of up to 1024 indoor units (64 groups) from up to 1 kilometer away. I n t e r lo c k c o n t r o l Enables interlocking control with external equipment such as heat reclaim ventilation (HRV). Mould prevention M o u ld -r e s is t a n t t r e a t m e n t fo r filt e r M o u ld -pr o o fin g d r a in pa n Sanitary filter has mould-resistant treatment. Mould-proofing maintains hygiene by preventing growth in highly humid conditions. Others T w in / tr iple / do u ble tw in m u lti o pe r a tio n Simultaneously operates 2–4 indoor units with a single outdoor unit. 37 P E fin To achieve increased durability by improved resistance to salt corrosion and atmospheric pollution, coated PE fins (with special acryl pretreatment) are used for the heat exchanger of the outdoor unit. In high corrosive areas, regular maintenance needs to be carried out. Options H ig h -e ffic ie n c y filt e r u n it F r e s h -a ir in t a k e k it Two types are available: 65% and 90% colorimetry. U lt r a lo n g -life filt e r Requires no maintenance for about 4 years* (10,000 h) in stores and offices. * For dust concentration of 0.15 mg/m 3 You can provide air-conditioning with fresh air from outside. Convenient for places where a ventilation fan cannot be installed. Note: *Connecting ducts, insect nets, fire dampers, air filters, and other parts should, as required, be procured locally. **Outside Air fan interlocked with air conditioning unit is necessary. Optional PCB(KRP1C63)is required for interlocking. ***It is recommended that the volume of outdoor air introduced through the kit is limited to 10% of the maximum airflow rate of the indoor unit. Introducing higher quantities will increase the operating noise and may also influence temperature sending. 38 CEILING MOUNTED CASSETTE TYPE Indoor unit Model Name Outdoor unit Power supply Cooling capacity 1a/1b kW Btu/h kcal/h kW Power consumption 1a/1b Indoor unit Outdoor unit 35 FHC35KVE Colour Unit Decoration panel m3/min Airflow rate (H) cfm dB(A) Sound level (H/L) 2 mm Dimensions Unit (HX WX D) mm Decoration panel kg Unit Machine weight kg Decoration panel °CWB Certified operation range Colour Compressor Type Motor output kW Refrigerant charge (R-22) Sound level 2 Dimensions (HX WX D) Machine weight Certified operation range Liquid (Flare) Piping connections Gas (Flare) Drain Indoor unit Outdoor unit Max. interunit piping length Max. installation level difference Heat insulation kg CEILING SUSPENDED CASSETTE TYPE 50 FHC50KVE 60 FHC60KVE 71 100 125 140 FHYC71KVE FHYC100KVE FHYC125KVE FHYC140KVE R71LUV1 R100LUV1 R35GV1 R50GV1 R60GV1 R125LUY1 R140LUY1 R71LUY1 R100LUY1 VE: 1 Phase, 220–240/220 V, 50/60 Hz V1: 1 Phase, 220–240 V, 50 Hz Y1: 3 Phase, 380–415 V, 50 Hz 3.54/3.5 5.34/5.3 6.44/6.4 7.8/7.7 10.6/10.5 13.0/12.8 14.5/14.2 12,100/11,900 18,200/18,100 22,000/21,800 26,600/26,200 36,100/35,700 44,500/43,600 49,400/48,400 3,040/3,010 4,590/4,560 5,540/5,500 6,700/6,600 9,100/9,000 11,200/11,000 12,500/12,200 3.07/3.07 (V1) 4.01/4.01 (V1) 1.20/1.20 2.02/2.01 2.45/2.44 4.96/4.96 5.02/5.02 3.05/3.05 (Y1) 3.96/3.96 (Y1) ---------White 14 15 19 19 28 33 35 494 529 670 670 988 1,164 1,235 33/29 33/29 35/30 35/30 39/34 42/36 44/37 230X 840X 840 230X 840X 840 230X 840X 840 230X 840X 840 288X 840X 840 288X 840X 840 288X 840X 840 40X 950X 950 40X 950X 950 40X 950X 950 40X 950X 950 40X 950X 950 40X 950X 950 40X 950X 950 24 24 24 24 28 28 28 5 5 5 5 5 5 5 14 to 23 14 to 25 Ivory white Hermetically sealed rotary type Hermetically sealed scroll type 1.1 1.7 2.2 2.24 3.00 3.75 4.50 1.10 1.20 1.50 2.8 3.7 3.7 4.1 (Charged for 10 m) (Charged for 10 m) (Charged for 5 m) (Charged for 30 m) (Charged for 30 m) (Charged for 30 m) (Charged for 30 m) dB(A) 48 49 54 48 49 49 54 mm 540X 750X 270 540X 750X 270 685X 800X 300 770X 900X 320 1,170X 900X 320 1,170X 900X 320 1,345X 900X 320 kg 37 42 61 72 (V1), 71 (Y1) 87 (V1), 84 (Y1) 98 109 °CDB 19.4 to 46 19.4 to 54 19.4 to 46 21 to 46, -15 to 46 3 (Option installed) mm o/ 6.4 o/ 6.4 o/ 6.4 o/ 9.5 o/ 9.5 o/ 9.5 o/ 9.5 mm o/ 12.7 o/ 15.9 o/ 15.9 o/ 15.9 o/ 19.1 o/ 19.1 o/ 19.1 mm I.Do/ 25X O.Do/ 32 I.Do/ 25X O.Do/ 32 I.Do/ 25X O.Do/ 32 I.Do/ 25X O.Do/ 32 I.Do/ 25X O.Do/ 32 I.Do/ 25X O.Do/ 32 I.Do/ 25X O.Do/ 32 mm o/ 18.0 (Hole) o/ 18.0 (Hole) o/ 18.0 (Hole) o/ 26.0 (Hole) o/ 26.0 (Hole) o/ 26.0 (Hole) o/ 26.0 (Hole) 25 30 50 (equivalent length 70 m) m 15 30 m Both liquid and gas piping Indoor unit Outdoor unit Power supply Cooling capacity 1a/1b Power consumption 1a/1b Indoor unit Outdoor unit Colour Airflow rate (H) Sound level (H/L) 2 Dimensions (HX WX D) Machine weight Certified operation range Colour Compressor Type Motor output Refrigerant charge (R-22) Sound level 2 Dimensions (HX WX D) Machine weight Certified operation range Piping Liquid (Flare) connections Gas (Flare) Drain Indoor unit Outdoor unit Max. interunit piping length Max. installation level difference Heat insulation 35 FH35BVE 71 100 125 FHY71BVE FHY100BVE FHY125BVE R71LUV1 R100LUV1 R35GV1 R50GV1 R60GV1 R125LUY1 R71LUY1 R100LUY1 VE: 1 Phase, 220–240/220 V, 50/60 Hz V1: 1 Phase, 220–240 V, 50 Hz Y1: 3 Phase, 380–415 V, 50 Hz kW 3.54/3.4 5.19/5.1 6.6/6.5 7.8/7.7 10.6/10.5 13.0/12.8 Btu/h 12,100/11,600 17,700/17,500 22,760/22,200 26,600/26,200 36,100/35,700 44,500/43,600 kcal/h 3,040/2,930 4,460/4,400 5,690/5,600 6,700/6,600 9,100/9,000 11,200/11,000 3.10/3.10 (V1) 3.90/3.90 (V1) 1.51/1.50 2.16/2.15 2.80/2.78 4.92/4.92 kW 3.08/3.08 (Y1) 3.85/3.85 (Y1) White 30 m3/min 13 13 16 17 24 1,059 cfm 458 458 564 600 847 44/39 dB(A) 37/32 38/33 38/33 39/35 42/37 mm 195X 960X 680 195X 960X 680 195X 1,160X 680 195X 1,160X 680 195X 1,400X 680 195X 1,590X 680 35 kg 23 24 26 27 32 °CWB 14 to 25 14 to 23 Ivory white Hermetically sealed rotary type Hermetically sealed scroll type 3.75 kW 1.1 1.7 2.2 2.24 3.00 3.7 1.10 1.20 1.50 2.8 3.7 kg (Charged for 10 m) (Charged for 10 m) (Charged for 5 m) (Charged for 30 m) (Charged for 30 m) (Charged for 30 m) dB(A) mm kg °CDB mm mm mm mm m m 48 540X 750X 270 37 19.4 to 46 o/ 6.4 o/ 12.7 I.D o/ 20X O.D o/ 26 o/ 18.0 (Hole) 25 50 FH50BVE 60 FH60BVE 49 540X 750X 270 42 19.4 to 54 o/ 6.4 o/ 15.9 I.D o/ 20X O.D o/ 26 o/ 18.0 (Hole) 30 15 49 48 49 770X 900X 320 1,170X 900X 320 1,170X 900X 320 98 72 (V1), 71 (Y1) 87 (V1), 84 (Y1) 21 to 46, -15 to 46 3 (Option installed) o/ 9.5 o/ 9.5 o/ 9.5 o/ 19.1 o/ 15.9 o/ 19.1 I.D o/ 20X O.D o/ 26 I.D o/ 20X O.D o/ 26 I.D o/ 20X O.D o/ 26 o/ 26.0 (Hole) o/ 26.0 (Hole) o/ 26.0 (Hole) 50 (equivalent length 70 m) 30 Both liquid and gas piping 54 685X 800X 300 61 19.4 to 46 o/ 6.4 o/ 15.9 I.D o/ 20X O.D o/ 26 o/ 18.0 (Hole) Note : 1 Rated cooling capacities are based on the following conditions: 1a Indoor temp., 27°CDB, 19.5°CWB; outdoor temp. 35°CDB. Equiv. refrigeration piping, 5 m (horizontal). 1b Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB. Equiv. refrigeration piping, 5 m (horizontal). (R71LU-R140LU is 7.5 m.) 2 Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions. 3 This value is for when year-round cooling kit (option) is installed. 39 kW Btu/h kcal/h kW Power consumption 1a/1b Colour Airflow rate (H) Sound level (H/L) 2 Dimensions (HX WX D) Machine weight Certified operation range Colour Outdoor Compressor Type unit Motor output Refrigerant charge (R-22) Sound level 2 Dimensions (HX WX D) Machine weight Certified operation range Piping Liquid (Flare) connections Gas (Flare) Drain Indoor unit Outdoor unit Max. interunit piping length Max. installation level difference Heat insulation m3/min cfm dB(A) mm kg °CWB kW kg dB(A) mm kg °CDB mm mm mm mm m m 100 125 FUY100FJV1 FUY125FJV1 R100LUV1 R125LUY1 R100LUY1 V1: 1 Phase, 220–240 V, 50 Hz Y1: 3 Phase, 380–415 V, 50 Hz 7.8/7.7 10.6/10.5 13.0/12.8 26,600/26,200 36,100/35,700 44,500/43,600 6,700/6,600 9,100/9,000 11,200/11,000 3.08/3.08 (V1) 4.07/4.07 (V1) 4.97/4.97 3.06/3.06 (Y1) 4.02/4.02 (Y1) White 19 29 32 670 1,023 1,129 40/35 43/38 44/39 165X 895X 895 230X 895X 895 230X 895X 895 25 31 31 14 to 25 Ivory white Hermetically sealed scroll type 2.24 3.00 3.75 2.8 (Charged for 30 m) 3.7 (Charged for 30 m) 3.7 (Charged for 30 m) 48 49 49 770X 900X 320 1,170X 900X 320 1,170X 900X 320 72 (V1), 71 (Y1) 87 (V1), 84 (Y1) 98 21 to 46, -15 to 46 3 (Option installed) o/ 9.5 o/ 9.5 o/ 9.5 o/ 15.9 o/ 19.1 o/ 19.1 I.D o/ 20X O.D o/ 26 I.D o/ 20X O.D o/ 26 I.D o/ 20X O.D o/ 26 o/ 26.0 (Hole) o/ 26.0 (Hole) o/ 26.0 (Hole) 50 (equivalent length 70 m) 30 Both liquid and gas piping CEILING MOUNTED CASSETTE CORNER TYPE Indoor unit Model Name CEILING SUSPENDED TYPE Model Name Outdoor unit Power supply Cooling capacity 1a/1b Indoor unit 71 FUY71FJV1 R71LUV1 R71LUY1 Indoor unit Model Name Outdoor unit Power supply Cooling capacity 1a/1b Power consumption 1a/1b Indoor unit Outdoor unit 45 FHK45FV1 60 FHK60FV1 R35GV1 R50GV1 R60GV1 kW Btu/h kcal/h 3.54/3.4 12,100/11,600 3,040/2,930 kW 1.41/1.40 Unit Decoration panel m3/min Airflow rate (H) cfm dB(A) Sound level (H/L) 2 mm Dimensions Unit (HX WX D) mm Decoration panel kg Unit Machine weight kg Decoration panel °CWB Certified operation range Colour Compressor Type Motor output kW kg Refrigerant charge (R-22) dB(A) Sound level 2 mm Dimensions (HX WX D) kg Machine weight Liquid (Flare) Gas (Flare) Drain Indoor unit Outdoor unit Max. interunit piping length Max. installation level difference Heat insulation 71 FHYK71FJV1 R71LUV1 R71LUY1 V1: 1 Phase, 220–240 V, 50 Hz Y1: 3 Phase, 380–415 V, 50 Hz 5.19/5.1 6.6/6.5 17,700/17,500 22,760/22,200 4,460/4,400 5,690/5,600 2.25/2.24 2.76/2.74 7.8/7.7 26,600/26,200 6,700/6,600 3.07/3.07 (V1) 3.05/3.05 (Y1) ---------White Colour Certified operation range Piping connections 35 FHK35FV1 12 423 39/33 215X 1,110X 710 70X 1,240X 800 30 8.5 12 423 39/34 215X 1,110X 710 70X 1,240X 800 31 8.5 14 to 23 17 600 41/36 215X 1,310X 710 70X 1,440X 800 33 9.5 Ivory white Hermetically sealed rotary type 1.1 1.7 2.2 1.10 (Charged for 10 m) 1.20 (Charged for 10 m) 1.50 (Charged for 5 m) 48 49 54 540X 750X 270 540X 750X 270 685X 800X 300 37 42 61 °CDB 19.4 to 46 19.4 to 54 19.4 to 46 mm mm mm mm m m o/ 6.4 o/ 12.7 I.D o/ 25X O.D o/ 32 o/ 18.0 (Hole) 25 o/ 6.4 o/ 15.9 I.D o/ 25X O.D o/ 32 o/ 18.0 (Hole) o/ 6.4 o/ 15.9 I.D o/ 25X O.D o/ 32 o/ 18.0 (Hole) 30 15 17 600 41/36 215X 1,310X 710 70X 1,440X 800 33 9.5 14 to 25 Hermetically sealed scroll type 2.24 2.8 (Charged for 30 m) 48 770X 900X 320 72 (V1), 71 (Y1) 21 to 46 -15 to 46 3 (Option installed) o/ 9.5 o/ 15.9 I.D o/ 25X O.D o/ 32 o/ 26.0 (Hole) 50 (equivalent length 70 m) 30 Both liquid and gas piping Note : 1 Rated cooling capacities are based on the following conditions: 1a Indoor temp., 27°CDB, 19.5°CWB; outdoor temp. 35°CDB. Equiv. refrigeration piping, 5 m (horizontal). 1b Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB. Equiv. refrigeration piping, 5 m (horizontal). (R71LU-R125LU is 7.5 m.) 2 Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions. 3 This value is for when year-round cooling kit (option) is installed. 40 CEILING MOUNTED BUILT-IN TYPE Indoor unit Model Name Outdoor unit Power supply Cooling capacity 1a/1b kW Btu/h kcal/h kW Power consumption 1a/1b Indoor unit Outdoor unit 35 FHB35FV1 Colour Unit Decoration panel m3/min Airflow rate (H) cfm dB(A) Sound level (H/L) 2 mm Dimensions Unit (HX WX D) mm Decoration panel kg Unit Machine weight kg Decoration panel °CWB Certified operation range Colour Compressor Type Motor output kW Refrigerant charge (R-22) Sound level 2 Dimensions (HX WX D) Machine weight Certified operation range Liquid (Flare) Piping connections Gas (Flare) Drain Indoor unit Outdoor unit Max. interunit piping length Max. installation level difference Heat insulation kg dB(A) mm kg °CDB mm mm mm mm m m FLOOR STANDING TYPE 45 FHB45FV1 60 FHB60FV1 71 100 125 FHYB71FV1 FHYB100FV1 FHYB125FV1 R71LUV1 R100LUV1 R35GV1 R50GV1 R60GV1 R125LUY1 R71LUY1 R100LUY1 V1: 1 Phase, 220–240 V, 50 Hz Y1: 3 Phase, 380–415 V, 50 Hz 3.54/3.4 5.19/5.1 6.6/6.5 7.8/7.7 10.6/10.5 13.0/12.8 12,100/11,600 17,700/17,500 22,760/22,200 26,600/26,200 36,100/35,700 44,500/43,600 3,040/2,930 4,460/4,400 5,690/5,600 6,700/6,600 9,100/9,000 11,200/11,000 3.13/3.13 (V1) 4.00/4.00 (V1) 1.47/1.46 2.33/2.32 2.78/2.76 4.74/4.74 3.11/3.11 (Y1) 3.95/3.95 (Y1) ---------White 11.5 14 17 19 27 35 405 494 600 670 953 1,235 38/32 39/34 41/35 41/35 41/35 44/38 300X 700X 800 300X 700X 800 300X 1,000X 800 300X 1,000X 800 300X 1,400X 800 300X 1,400X 800 55X 880X 500 55X 880X 500 55X 1,100X 500 55X 1,100X 500 55X 1,500X 500 55X 1,500X 500 30 31 41 41 51 52 3.5 3.5 4.5 4.5 6.5 6.5 14 to 23 14 to 25 Ivory white Hermetically sealed rotary type Hermetically sealed scroll type 1.1 1.7 2.2 2.24 3.00 3.75 1.10 1.20 1.50 2.8 3.7 3.7 (Charged for 10 m) (Charged for 10 m) (Charged for 5 m) (Charged for 30 m) (Charged for 30 m) (Charged for 30 m) 48 49 54 48 49 49 540X 750X 270 540X 750X 270 685X 800X 300 770X 900X 320 1,170X 900X 320 1,170X 900X 320 37 42 61 72 (V1), 71 (Y1) 87 (V1), 84 (Y1) 98 19.4 to 46 19.4 to 54 19.4 to 46 21 to 46, -15 to 46 3 (Option installed) o/ 6.4 o/ 6.4 o/ 6.4 o/ 9.5 o/ 9.5 o/ 9.5 o/ 12.7 o/ 15.9 o/ 15.9 o/ 15.9 o/ 19.1 o/ 19.1 I.D o/ 25X O.D o/ 32 I.D o/ 25X O.D o/ 32 I.D o/ 25X O.D o/ 32 I.D o/ 25X O.D o/ 32 I.D o/ 25X O.D o/ 32 I.D o/ 25X O.D o/ 32 o/ 18.0 (Hole) o/ 18.0 (Hole) o/ 18.0 (Hole) o/ 26.0 (Hole) o/ 26.0 (Hole) o/ 26.0 (Hole) 25 30 50 (equivalent length 70 m) 15 30 Both liquid and gas piping Indoor unit Outdoor unit Power supply Cooling capacity 1a/1b Power consumption 1a/1b Indoor unit Colour Airflow rate (H) Sound level (H/L) 2 Dimensions (HX WX D) Machine weight Certified operation range Colour Outdoor Compressor Type unit Motor output Refrigerant charge (R-22) Sound level 2 Dimensions (HX WX D) Machine weight Certified operation range Piping Liquid (Flare) connections Gas (Flare) Drain Indoor unit Outdoor unit Max. interunit piping length Max. installation level difference Heat insulation kW Btu/h kcal/h kW m3/min cfm dB(A) mm kg °CWB kW kg dB(A) mm kg °CDB mm mm mm mm m m 71 100 FAY71LVE FAY100FAVE R71LUV1 R100LUV1 R71LUY1 R100LUY1 VE: 1 Phase, 220–240/220 V, 50/60 Hz V1: 1 Phase, 220–240 V, 50 Hz Y1: 3 Phase, 380–415 V, 50 Hz 7.8/7.7 10.6/10.5 26,600/26,200 36,100/35,700 6,700/6,600 9,100/9,000 2.98/ 2.98(V1) 3.90/3.90 (V1) 3.85/3.85 (Y1) 2.96/2.96(Y1) White 19 23 670 811 43/37 45/41 290X 1,050X 230 360X 1,570X 200 13 26 14 to 25 Ivory white Hermetically sealed scroll type 2.24 3.00 2.8 (Charged for 30 m) 3.7 (Charged for 30 m) 48 49 770X 900X 320 1,170X 900X 320 72 (V1), 71 (Y1) 87 (V1), 84 (Y1) 21 to 46, -15 to 46 3 (Option installed) o/ 9.5 o/ 9.5 o/ 15.9 o/ 19.1 I.D o/ 13X O.D o/ 18 I.D o/ 20X O.D o/ 26 o/ 26.0 (Hole) o/ 26.0 (Hole) 50 (equivalent length 70 m) 30 Both liquid and gas piping Note : 1 Rated cooling capacities are based on the following conditions: (FHB) 1aSuction temp., 27°CDB, 19.5°CWB; outdoor temp. 35°CDB. Equiv. refrigeration piping, 5 m (horizontal). 1b Suction temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB. Equiv. refrigeration piping, 5 m (horizontal). (R71LU-R125LU is 7.5 m.) (FAY) 1aIndoor temp., 27°CDB, 19.5°CWB; outdoor temp. 35°CDB. Equiv. refrigeration piping, 5 m (horizontal). 1b Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB. Equiv. refrigeration piping, 5 m (horizontal). (R71LU-R100LU is 7.5 m.) 2 Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions. 3 This value is for when year-round cooling kit (option) is installed. 41 Outdoor unit Power supply Cooling capacity 1a/1b kW Btu/h kcal/h kW Power consumption 1a/1b Indoor unit Colour Airflow rate (H) Sound level (H/L) 2 Dimensions (HX WX D) Machine weight Certified operation range Colour Outdoor Compressor Type unit Motor output Refrigerant charge (R-22) Sound level 2 Dimensions (HX WX D) Machine weight Certified operation range Piping Liquid (Flare) connections Gas (Flare) Drain Indoor unit Outdoor unit Max. interunit piping length Max. installation level difference Heat insulation m3/min cfm dB(A) mm kg °CWB kW kg dB(A) mm kg °CDB mm mm mm mm m m 71 100 125 FVY71LAVE FVY100LAVE FVY125LAVE R71LUV1 R100LUV1 R125LUY1 R71LUY1 R100LUY1 VE: 1 Phase, 220–240/220 V, 50/60 Hz V1: 1 Phase, 220–240 V, 50 Hz Y1: 3 Phase, 380–415 V, 50 Hz 7.8/7.7 10.6/10.5 13.0/12.8 26,600/26,200 36,100/35,700 44,500/43,600 6,700/6,600 9,100/9,000 11,200/11,000 3.18/3.18 (V1) 4.03/4.03 (V1) 5.06/5.06 3.16/3.16 (Y1) 3.98/3.98 (Y1) White 18 28 32 635 988 1,129 41/35 46/40 49/43 1,850X 600X 270 1,850X 600X 350 1,850X 600X 350 39 46 47 14 to 25 Ivory white Hermetically sealed scroll type 2.24 3.00 3.75 2.8 (Charged for 30 m) 3.7 (Charged for 30 m) 3.7 (Charged for 30 m) 48 49 49 770X 900X 320 1,170X 900X 320 1,170X 900X 320 72 (V1), 71 (Y1) 87 (V1), 84 (Y1) 98 21 to 46, -15 to 46 3 (Option installed) o/ 9.5 o/ 9.5 o/ 9.5 o/ 15.9 o/ 19.1 o/ 19.1 I.D o/ 20X O.D o/ 26 I.D o/ 20X O.D o/ 26 I.D o/ 20X O.D o/ 26 o/ 26.0 (Hole) o/ 26.0 (Hole) o/ 26.0 (Hole) 50 (equivalent length 70 m) 30 Both liquid and gas piping DUCT CONNECTION LOW STATIC PRESSURE TYPE Outdoor unit Power supply Cooling capacity 1a/1b, 4 Power consumption 1a/1b Colour Airflow rate (H) Indoor unit Outdoor unit 25 FDBG25AVE Indoor unit Model Name WALL MOUNTED TYPE Model Name Indoor unit Model Name Fan Driving system Sound level (H/L) 2 Dimensions (HX WX D) Machine weight Certified operation range Colour Compressor Type Motor output Refrigerant charge (R-22) Sound level 2 Dimensions (HX WX D) Machine weight Certified operation range Piping Liquid (Flare) connections Gas (Flare) Drain Indoor unit Outdoor unit Max. interunit piping length Max. installation level difference Heat insulation kW Btu/h kcal/h kW m3/min cfm dB(A) mm kg °CWB kW kg dB(A) mm kg °CDB mm mm mm mm m m 35 FDBG35AVE 50 FDBG50AVE 60 FDBG60AVE 71 FDBG71AVE R71FUV1 R25JV1 R35JV1 R50GV1 R60GV1 R71FUY1 VE: 1 Phase, 220–240/220 V, 50/60 Hz V1: 1 Phase, 220–240 V, 50 Hz Y1: 3 Phase, 380–415 V, 50 Hz 2.64/2.60 3.54/3.50 5.34/5.30 7.03/6.97 7.80/7.70 9,000/8,900 12,100/11,900 18,200/18,100 24,000/23,800 26,600/26,200 2,270/2,250 3,040/3,010 4,590/4,560 6,050/6,000 6,700/6,600 0.88/0.87 1.25/1.24 2.06/2.05 2.76/2.75 2.82/2.80 ---------13 13 13 18 18 458 458 458 635 635 Direct drive (2 speed) 41/38 41/38 41/38 42/39 42/39 260X 900X 580 260X 900X 580 260X 900X 580 260X 1,300X 580 260X 1,300X 580 22 22 23 31 31 14 to 23 14 to 25 Ivory white Hermetically sealed rotary type Hermetically sealed type 0.7 1.1 1.7 2.2 2.2 0.8 1.0 1.20 1.50 2.10 (Charged for 10 m) (Charged for 10 m) (Charged for 10 m) (Charged for 5 m) (Charged for 5 m) 46 48 49 54 52 560X 695X 265 560X 695X 265 540X 750X 270 685X 800X 300 816X 880X 370 27 33 42 61 87 (V1), 84 (Y1) 19.4 to 54 19.4 to 46 21 to 52 19.4 to 46 o/ 6.4 o/ 6.4 o/ 6.4 o/ 6.4 o/ 9.5 o/ 9.5 o/ 12.7 o/ 15.9 o/ 15.9 o/ 15.9 3/4B 3/4B 3/4B 3/4B 3/4B o/ 18.0 (Hole) o/ 18.0 (Hole) o/ 18.0 (Hole) o/ 18.0 (Hole) o/ 26.0 (Hole) 25 30 50 (equivalent length 70 m) 15 30 Both liquid and gas piping Note : 1 Rated cooling capacities are based on the following conditions: (FVY) 1aIndoor temp., 27°CDB, 19.5°CWB; outdoor temp. 35°CDB. Equiv. refrigeration piping, 5 m (horizontal). 1b Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB. Equiv. refrigeration piping, 5 m (horizontal). (R71LU-R125LU is 7.5 m.) (FDBG) 1aSuction temp., 27°CDB, 19.5°CWB; outdoor temp. 35°CDB. Equiv. refrigeration piping, 5 m (horizontal). 1b Suction temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB. Equiv. refrigeration piping, 5 m (horizontal). 2 Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions. 3 This value is for when year-round cooling kit (option) is installed. 4 Capacities are gross, with no deduction made for evaporator fan motor heat. 42 DUCT CONNECTION MIDDLE STATIC PRESSURE TYPE Indoor unit Model Name Outdoor unit Power supply Cooling capacity 1a/1b Power consumption 1a/1b Colour Indoor Fan Airflow rate (H) unit Sound level (H) 2 Dimensions (HX WX D) Machine weight Certified operation range Colour Outdoor Compressor Type unit Motor output Refrigerant charge (R-22) Sound level 2 Dimensions (HX WX D) Machine weight Certified operation range Piping Liquid (Flare) connections Gas (Flare) Drain Indoor unit Outdoor unit Max. interunit piping length Max. installation level difference Heat insulation kW Btu/h kcal/h kW m3/min cfm dB(A) mm kg °CWB kW kg dB(A) mm kg °CDB mm mm mm mm m m Outdoor unit Power supply Cooling capacity 1a/1b Power consumption 1a/1b Colour Fan Airflow rate (H) External static pressure Sound level (H) 2 Dimensions (HX WX D) Machine weight Certified operation range Colour Outdoor Compressor Type unit Motor output Refrigerant charge (R-22) Sound level 2 Dimensions (HX WX D) Machine weight Certified operation range Piping Liquid (Flare) connections Gas (Flare) Drain Indoor unit Outdoor unit Max. interunit piping length Max. installation level difference Heat insulation 100 125 140 180 FDMG100AV1 FDMG125AV1 FDMG140AV1 FDMG180AV1 R100FUV1 R125FUY1 RG140AY1 RG180AY1 R100FUY1 V1: 1 Phase, 220–240 V, 50 Hz Y1: 3 Phase, 380–415 V, 50 Hz 8.8/8.7 10.6/10.5 13.1/12.9 14.5/14.2 17.2/16.8 30,000/29,600 36,100/35,700 44,500/43,600 49,400/48,400 58,700/57,500 7,600/7,500 9,100/9,000 11,200/11,000 12,500/12,200 14,700/14,400 3.15/3.13 4.08/4.04 4.89/4.85 5.25/5.25 6.45/6.45 ---------23 34 37 42 42 811 1,200 1,306 1,412 1,482 42 44 45 46 47 305X 1,350X 680 305X 1,550X 680 305X 1,550X 680 305X 1,550X 680 305X 1,900X 680 43 51 52 52 58 14 to 25 Ivory white Hermetically sealed type Hermetically sealed scroll type 2.20 3.00 3.75 4.50 4.50 2.4 (Charged for 5 m) 2.4 (Charged for 5 m) 2.8 (Charged for 5 m) 2.9 (Charged for 5 m) 2.8 (Charged for 5 m) 52 56 57 55 56 816X 880X 370 1,215X 880X 370 1,215X 880X 370 1,345X 880X 370 1,345X 880X 370 87 (V1), 84 (Y1) 117 (V1), 109 (Y1) 110 113 114 21 to 52 21 to 50 o/ 9.5 o/ 9.5 o/ 9.5 o/ 9.5 o/ 9.5 o/ 15.9 o/ 19.1 o/ 19.1 o/ 19.1 o/ 19.1 3/4B 3/4B 3/4B 3/4B 3/4B o/ 26.0 (Hole) o/ 26.0 (Hole) o/ 26.0 (Hole) o/ 26.0 (Hole) o/ 26.0 (Hole) 50 (equivalent length 70 m) 30 Both liquid and gas piping 71 FDYM03FAV1 R71LUV1 R71LUY1 Indoor unit Model Name Indoor unit 71 FDMG71AV1 RG71AV1 RG71AY1 kW Btu/h kcal/h kW m3/min cfm Pa(mmH2O) dB(A) mm kg °CWB kW kg dB(A) mm kg °CDB mm mm mm mm m m 100 125 140 FDYM04FAV1 FDYM05FAV1 FDYM06FAV1 R100LUV1 R125LUY1 R140LUY1 R100LUY1 V1: 1 Phase, 220–240 V, 50 Hz Y1: 3 Phase, 380–415 V, 50 Hz 7.8/7.7 10.6/10.5 13.0/12.8 14.5/14.2 26,600/26,200 36,100/35,700 44,500/43,600 49,400/48,400 6,700/6,600 9,100/9,000 11,200/11,000 12,500/12,200 3.25/3.25 (V1) 4.08/4.08 (V1) 5.06/5.06 5.18/5.18 3.23/3.23 (Y1) 4.03/4.03 (Y1) ---------20 26 35 37 706 917 1,235 1,306 98(10) 98(10) 98(10) 98(10) 39 39 44 46 295X 1,100X 680 295X 1,500X 680 295X 1,500X 680 295X 1,500X 680 42 56 57 57 14 to 25 Ivory white Hermetically sealed scroll type 2.24 3.00 3.75 4.50 2.8 (Charged for 30 m) 3.7 (Charged for 30 m) 3.7 (Charged for 30 m) 4.1 (Charged for 30 m) 48 49 49 54 770X 900X 320 1,170X 900X 320 1,170X 900X 320 1,345X 900X 320 72 (V1), 71 (Y1) 87 (V1), 84 (Y1) 98 109 21 to 46, -15 to 46 3 (Option installed) o/ 9.5 o/ 9.5 o/ 9.5 o/ 9.5 o/ 15.9 o/ 19.1 o/ 19.1 o/ 19.1 I.D o/ 25X O.D o/ 32 I.D o/ 25X O.D o/ 32 I.D o/ 25X O.D o/ 32 I.D o/ 25X O.D o/ 32 o/ 26.0 (Hole) o/ 26.0 (Hole) o/ 26.0 (Hole) o/ 26.0 (Hole) 50 (equivalent length 70 m) 30 Both liquid and gas piping Note : 1 Rated cooling capacities are based on the following conditions: 1a Suction temp., 27°CDB, 19.5°CWB; outdoor temp. 35°CDB. Equiv. refrigeration piping, 5 m (horizontal). 1b Suction temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB. Equiv. refrigeration piping, 5 m (horizontal). (R71LU-R140LU is 7.5 m.) 2 Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions. 3 This value is for when year-round cooling kit (option) is installed. 43 DUCT CONNECTION HIGH STATIC PRESSURE TYPE Model Name Power supply Cooling capacity 1a/1b Power consumption 1a/1b Colour Indoor Airflow rate (H) unit Fan Outdoor unit External static pressure Driving system Sound level (H) 2 Dimensions (HX WX D) Machine weight Certified operation range Colour Compressor Type Motor output Refrigerant charge (R-22) Sound level Dimensions (HX WX D) Machine weight Certified operation range Piping Liquid (Flare) connections Gas (Flare) Drain Indoor unit Outdoor unit Max. interunit piping length Max. installation level difference Heat insulation 2 Model Name Power supply Cooling capacity 1a/1b kW Btu/h kcal/h kW 8.1/ 7.9 27,800/ 27,000 7,000/6,800 2.50/2.48 m3/min cfm Pa(mmH2O) 26 917 69 (7) dB(A) mm kg °CWB 46 450X 650X 850 51 kW 3.0 2.1 (Charged for 5 m) kg dB(A) mm kg °CDB mm mm mm mm m m Power consumption 1a/1b Colour Airflow rate (H) Fan External static pressure Driving system Sound level (H) 2 Dimensions (HX WX D) Machine weight Certified operation range Colour Compressor Type Motor output Refrigerant charge (R-22) Sound level 2 Dimensions (HX WX D) Machine weight Certified operation range Piping Liquid (Flare) connections Gas (Brazing) Drain Indoor unit Outdoor unit Max. interunit piping length Max. installation level difference Heat insulation 100 125 FD04KY1 FD05KY1 R100FUY1 R125FUY1 Y1: 3 phase, 380–415 V, 50 Hz 11.0/10.8 14.0/13.8 37,700/36,900 47,600/46,800 9,500/9,300 12,000/11,800 3.52/3.48 4.19/4.15 ---------30 46 1,059 1,623 88 (9) Belt drive 49 450X 900X 850 59 72 14 to 25 Ivory white Hermetically sealed type 3.8 4.5 2.4 2.8 (Charged for 5 m) (Charged for 5 m) 52 816X 880X 370 84 56 140 FD06KY1 RU06KY1 17.4/17.2 59,500/58,800 15,000/14,800 5.7/5.7 52 1,835 51 450X 1,130X 850 79 Hermetically sealed scroll type 4.5 3.0 (Charged for 5 m) 57 110 59 1,345X 880X 320 112 o/ 9.5 o/ 19.1 o/ 9.5 o/ 19.1 1,215X 880X 370 109 21 to 52 o/ 9.5 o/ 15.9 o/ 9.5 o/ 19.1 3/4B o/ 26.0 (Hole) o/ 26.0 (Hole) 50 (equivalent length 70 m) 30 Both liquid and gas piping o/ 26.0 (Hole) 200 FD08KY1 RU08KUY1 Indoor unit Outdoor unit Indoor unit Outdoor unit 71 FD03KY1 R71FUY1 Indoor unit Outdoor unit kW Btu/h kcal/h kW 24.3/24.0 83,000/81,800 20,900/20,600 7.5/7.4 m3/min cfm Pa(mmH2O) 68 2,400 ---------- 250 400 FD10KY1 FD15KY1 RU10KUY1 RU08KUY1X 2 Y1: 3 phase, 380–415 V, 50 Hz 29.7/29.2 48.6/47.9 101,200/ 99,600 166,000/163,500 25,500/25,100 41,800/41,200 9.9/9.8 15.0/14.8 ---------83 136 2,929 4,800 98 (10) 500 FD20KY1 RU10KUY1X 2 59.3/58.4 202,400/199,400 51,000/ 50,200 19.8/19.6 166 5,859 147 (15) Belt drive dB(A) mm kg °CWB 51 500X 1,130X 850 93 kW 7.5 5.0 (Charged for 5 m) 60 1,220X 1,280X 690 185 kg dB(A) mm kg °CDB mm mm mm mm m m 53 500X 1,330X 850 104 58 625X 1,620X 850 161 60 625X 1,980X 850 187 14 to 25 Ivory white Hermetically sealed scroll type 9.0 7.5 X 2 6.1 5.0 (Charged for 5 m) (Charged for 5 m)X 2 61 60 3 (1,220X 1,280X 690) X 2 1,440X 1,280X 690 200 185X 2 21 to 52 o/ 15.9 o/ 12.7 X 2 o/ 31.8 o/ 25.4 X 2 o/ 12.7 o/ 25.4 3/4B 9.0X 2 6.1 (Charged for 5 m)X 2 61 3 (1,440X 1,280X 690) X 2 200X 2 o/ 15.9 X 2 o/ 31.8 X 2 1B ---------50 (equivalent length 70 m) 30 Both liquid and gas piping Note : Models RU08K(U)Y1 and RU10K(U)Y1 are recommended for commercial facilities. 1 Rated cooling capacities are based on the following conditions: 1a Suction temp., 27°CDB, 19.5°CWB; outdoor temp. 35°CDB. Equiv. refrigeration piping, 5 m (horizontal). 1b Suction temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB. Equiv. refrigeration piping, 5 m (horizontal). 2 Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions. 3 Specification for outdoor unit is for a single unit only. 44 Simultaneous operation system DUCT CONNECTION HIGH STATIC PRESSURE TYPE Model Name Power supply Cooling capacity 1a/1b Indoor unit Outdoor unit Power consumption Colour Airflow rate (H) 1a/1b Indoor unit Fan Outdoor unit 200 FD08KY1 RU08KY1 External static pressure Driving system Sound level (H) 2 Dimensions (HX WX D) Machine weight Certified operation range Colour Compressor Type Motor output Refrigerant charge (R-22) Sound level 2 Dimensions (HX WX D) Machine weight Certified operation range Piping Liquid (Brazing) connections Gas (Brazing) Drain Indoor unit Outdoor unit Max. interunit piping length Max. installation level difference Heat insulation kW Btu/h kcal/h kW 24.3/24.0 83,000/81,800 20,900/20,600 7.5/7.4 m3/min cfm Pa(mmH2O) 68 2,400 CEILING MOUNTED CASSETTE TYPE 250 400 FD10KY1 FD15KY1 RU10KY1 RU08KY1X 2 Y1: 3 phase, 380–415 V, 50 Hz 29.7/29.2 48.6/47.9 101,200/ 99,600 166,000/163,500 25,500/25,100 41,800/41,200 9.9/9.8 15.0/14.8 ---------83 136 2,929 4,800 98 (10) 500 FD20KY1 RU10KY1X 2 59.3/58.4 202,400/199,400 51,000/ 50,200 19.8/19.6 166 5,859 kW kg dB(A) mm kg °CDB mm mm mm mm m m 51 500X 1,130X 850 93 7.5 5.0 53 500X 1,330X 850 104 (Field charge required for 5 m) 4 58 625X 1,620X 850 161 (Field charge required for 5 m) 4 60 1,220X 1,280X 690 177 61 1,440X 1,280X 690 190 o/ 12.7 o/ 25.4 o/ 15.9 o/ 31.8 3/4B Note : Models RU08K(U)Y1 and RU10K(U)Y1 are recommended for commercial facilities. 1 Rated cooling capacities are based on the following conditions: 1a Suction temp., 27°CDB, 19.5°CWB; outdoor temp. 35°CDB. Equiv. refrigeration piping, 5 m (horizontal). 1b Suction temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB. Equiv. refrigeration piping, 5 m (horizontal). 2 Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions. 3 Specification for outdoor unit is for a single unit only. 4 This is the amount of refrigerant required for piping of five meters or less. Since the unit does not contain refrigerant when shipped from the factory, it must be added at the installation site. For details, please refer to the installation manual. 61 3 (1,440X 1,280X 690) X 2 190 X 2 o/ 15.9 X 2 o/ 31.8 X 2 1B ---------50 (equivalent length 70 m) 30 Both liquid and gas piping kW Colour Unit Decoration panel m3/min Airflow rate (H) cfm Sound level (H/L) 2 dB(A) mm Dimensions Unit (HX WX D) Decoration mm panel Machine weight (Field charge required for 5 m) 4 X 2 60 3 (1,220X 1,280X 690) X 2 177 X 2 21 to 52 o/ 12.7 X 2 o/ 25.4 X 2 kW Btu/h kcal/h Power consumption 1a/1b 9.0X 2 6.1 (Field charge required for 5 m) 4 X 2 Outdoor unit Power supply Cooling capacity 1a/1b 60 625X 1,980X 850 187 14 to 25 Ivory white Hermetically sealed scroll type 9.0 7.5 X 2 6.1 5.0 Indoor unit Model Name Indoor unit 3 147 (15) Belt drive dB(A) mm kg °CWB TWIN & TRIPLE & DOUBLE TWIN MULTI Outdoor unit Unit Decoration panel Certified operation range Colour Compressor Type Motor output Refrigerant charge (R-22) 40X 950X 950 40X 950X 950 40X 950X 950 40X 950X 950 40X 950X 950 40X 950X 950 kg 24 24 24 24 28 28 kg 5 5 5 5 5 5 °CWB kW kg Sound level 2 dB(A) mm Dimensions (HX WX D) kg Machine weight Certified operation range °CDB mm Piping Liquid (Flare) connections Gas mm mm Drain Indoor unit Outdoor unit mm m Max. interunit piping length m Max. installation level difference Heat insulation Indoor unit Model Name Outdoor unit Power supply Cooling capacity 1a/1b Machine weight 2.24 2.8 (Charged for 30 m) 48 770X 900X 320 72 (V1), 71 (Y1) o/ 9.5 o/ 15.9 (Flare) I.D o/ 25X O.D o/ 32 o/ 26.0 (Hole) 14 to 25 Ivory white Hermetically sealed scroll type 3.00 3.75 4.50 3.7 3.7 4.1 (Charged for 30 m) (Charged for 30 m) (Charged for 30 m) 49 49 54 1,170X 900X 320 1,170X 900X 320 1,345X 900X 320 87 (V1), 84 (Y1) 98 109 21 to 46, -15 to 46 4 (Option installed) o/ 9.5 o/ 9.5 o/ 9.5 o/ 19.1 (Flare) o/ 19.1 (Flare) o/ 19.1 (Flare) I.D o/ 25X O.D o/ 32 I.D o/ 25X O.D o/ 32 I.D o/ 25X O.D o/ 32 o/ 26.0 (Hole) o/ 26.0 (Hole) o/ 26.0 (Hole) 50 (equivalent length 70 m) 30 Both liquid and gas piping 140 FHYC50KVEX 3 R140LUY1 kW Btu/h kcal/h kW Power consumption 1a/1b Colour Unit Indoor Decoration panel unit 3 m3/min Airflow rate (H) cfm Sound level (H/L) 2 dB(A) mm Dimensions Unit (HX WX D) Decoration mm panel Unit Decoration panel 71 100 125 140 200 250 FHYC35KVEX 2 FHYC50KVEX 2 FHYC60KVEX 2 FHYC71KVEX 2 FHYC100KVEX 2 FHYC125KVEX 2 R71LUV1 R100LUV1 R125LUY1 R140LUY1 R200KUY1 R250KUY1 R71LUY1 R100LUY1 VE: 1 Phase, 220–240/220 V, 50/60 Hz V1: 1 Phase, 220–240 V, 50 Hz Y1: 3 Phase, 380–415 V, 50 Hz 7.8/7.7 10.6/10.5 13.0/12.8 14.5/14.2 22.5/22.2 27.1/26.6 26,600/26,200 36,100/35,700 44,500/43,600 49,400/48,400 76,800/75,800 92,500/90,800 6,700/6,600 9,100/9,000 11,200/11,000 12,500/12,200 19,400/19,100 23,300/22,900 3.17/3.17 (V1) 4.06/4.06 (V1) 5.01/5.01 5.02/5.02 7.7/7.6 9.7/9.7 3.15/3.15 (Y1) 4.01/4.01 (Y1) ------------White 14 15 19 19 28 33 494 529 670 670 988 1,164 33/29 33/29 35/30 35/30 39/34 42/36 230X 840X 840 230X 840X 840 230X 840X 840 230X 840X 840 288X 840X 840 288X 840X 840 14.5/14.2 49,400/48,400 12,500/12,200 5.02/5.02 15 529 33/29 230X 840X 840 5.5 9.0 5.3 5.7 (Charged for 5 m) (Charged for 5 m) 60 61 1,220X 1,280X 690 1,440X 1,280X 690 178 202 -5 to 52 o/ 12.7 o/ 15.9 o/ 25.4 (Flange) o/ 28.6 (Flange) I.D o/ 25X O.D o/ 32 I.D o/ 25X O.D o/ 32 ----------------- 200 200 FHYC71KVEX 3 FHYC50KVEX 4 R200KUY1 R200KUY1 VE: 1 Phase, 220–240/220 V, 50/60 Hz Y1: 3 Phase, 380–415 V, 50 Hz 22.5/22.2 22.5/22.2 76,800/75,800 76,800/75,800 19,400/19,100 19,400/19,100 7.7/7.6 7.7/7.6 ------------White 19 15 670 529 33/29 35/30 33/29 230X 840X 840 230X 840X 840 250 FHYC60KVEX 4 R250KUY1 27.1/26.6 92,500/90,800 23,300/22,900 9.7/9.7 19 670 35/30 230X 840X 840 40X 950X 950 40X 950X 950 40X 950X 950 40X 950X 950 kg 24 24 24 24 kg 5 5 5 5 Certified operation range °CWB Colour Outdoor Compressor Type unit kW 4.50 Motor output kg 4.1 (Charged for 30 m) Refrigerant charge (R-22) 54 Sound level 2 dB(A) 1,345X 900X 320 mm Dimensions (HX WX D) 109 kg Machine weight Certified operation range °CDB 21 to 46, -15 to 46 4 (Option installed) mm Piping Liquid (Flare) o/ 9.5 connections Gas mm o/ 19.1 (Flare) mm Drain Indoor unit I.D o/ 25X O.D o/ 32 Outdoor unit mm o/ 26.0 (Hole) m Max. interunit piping length m Max. installation level difference Heat insulation 14 to 25 Ivory white Hermetically sealed scroll type 5.5 5.5 5.3 (Charged for 5 m) 5.3 (Charged for 5 m) 60 60 1,220X 1,280X 690 1,220X 1,280X 690 178 178 -5 to 52 o/ 12.7 o/ 12.7 o/ 25.4 (Flange) o/ 25.4 (Flange) I.D o/ 25X O.D o/ 32 I.D o/ 25X O.D o/ 32 ----------------50 (equivalent length 70 m) 30 Both liquid and gas piping 9.0 5.7 (Charged for 5 m) 61 1,440X 1,280X 690 202 o/ 15.9 o/ 28.6 (Flange) I.D o/ 25X O.D o/ 32 --------- Note : Models R200KU and R250KU are recommended for commercial facilities. 1 Rated cooling capacities are based on the following conditions: 1a Indoor temp., 27°CDB, 19.5°CWB; outdoor temp. 35°CDB. Equiv. refrigeration piping, 5 m (horizontal). 1b Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB. Equiv. refrigeration piping, 5 m (horizontal). (R71LU-R140LU is 7.5 m.) 2 Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions. 3 Values shown are for a single unit only. 4 This value is for when year-round cooling kit (option) is installed. 45 46 Simultaneous operation system TWIN & TRIPLE & DOUBLE TWIN MULTI CEILING SUSPENDED TYPE Indoor unit Model Name Outdoor unit Power supply Cooling capacity 1a/1b kW Btu/h kcal/h Power consumption 1a/1b Indoor unit 3 Outdoor unit kW Colour Airflow rate (H) m3/min cfm dB(A) Sound level (H/L) 2 mm Dimensions (HX WX D) kg Machine weight ° Certified operation range CWB Colour Compressor Type kW Motor output Refrigerant charge (R-22) kg dB(A) Sound level mm Dimensions (HX WX D) kg Machine weight Certified operation range °CDB mm Piping Liquid (Flare) connections Gas mm mm Drain Indoor unit Outdoor unit mm m Max. interunit piping length m Max. installation level difference Heat insulation 2 DUCT CONNECTION MIDDLE STATIC PRESSURE TYPE 71 100 125 140 200 250 FHY35BVE × 2 FHY50BVE × 2 FHY60BVE × 2 FHY71BVE × 2 FHY100BVE × 2 FHY125BVE × 2 R71LUV1 R100LUV1 R125LUY1 R140LUY1 R200KUY1 R250KUY1 R71LUY1 R100LUY1 VE: 1 Phase, 220–240/220 V, 50/60 Hz V1: 1 Phase, 220–240 V, 50 Hz Y1: 3 Phase, 380–415 V, 50 Hz 7.8/7.7 10.6/10.5 13.0/12.8 14.5/14.2 22.5/22.2 27.1/26.6 26,600/26,200 36,100/35,700 44,500/43,600 49,400/48,400 76,800/75,800 92,500/90,800 6,700/6,600 9,100/9,000 11,200/11,000 12,500/12,200 19,400/19,100 23,300/22,900 3.20/3.20 (V1) 3.95/3.95 (V1) 4.98/4.98 5.17/5.17 7.7/7.6 9.7/9.7 3.18/3.18 (Y1) 3.90/3.90 (Y1) White 13 13 16 17 24 30 458 458 564 600 847 1,059 37/32 38/33 38/33 39/35 42/37 44/39 195X 960X 680 195X 960X 680 195X 1,160X 680 195X 1,160X 680 195X 1,400X 680 195X 1,590X 680 23 24 26 27 32 35 14 to 25 Ivory white Hermetically sealed scroll type 2.24 3.00 3.75 4.50 5.5 9.0 2.8 3.7 3.7 4.1 5.3 5.7 (Charged for 30 m) (Charged for 30 m) (Charged for 30 m) (Charged for 30 m) (Charged for 5 m) (Charged for 5 m) 48 49 49 54 60 61 770X 900X 320 1,170X 900X 320 1,170X 900X 320 1,345X 900X 320 1,220X 1,280X 690 1,440X 1,280X 690 72 (V1), 71 (Y1) 87 (V1), 84 (Y1) 98 109 178 202 21 to 46, -15 to 46 4 (Option installed) -5 to 52 o/ 9.5 o/ 9.5 o/ 9.5 o/ 9.5 o/ 12.7 o/ 15.9 o/ 15.9 (Flare) o/ 19.1 (Flare) o/ 19.1 (Flare) o/ 19.1 (Flare) o/ 25.4 (Flange) o/ 28.6 (Flange) I.D o/ 20X O.D o/ 26 I.D o/ 20X O.D o/ 26 I.D o/ 20X O.D o/ 26 I.D o/ 20X O.D o/ 26 I.D o/ 20X O.D o/ 26 I.D o/ 20X O.D o/ 26 ----------------o/ 26.0 (Hole) o/ 26.0 (Hole) o/ 26.0 (Hole) o/ 26.0 (Hole) 50 (equivalent length 70 m) 30 Both liquid and gas piping 140 200 200 FHY50BVE × 3 FHY71BVE × 3 FHY50BVE × 4 R140LUY1 R200KUY1 R200KUY1 VE: 1 Phase, 220–240/220 V, 50/60 Hz Y1: 3 Phase, 380–415 V,50 Hz kW 14.5/14.2 22.5/22.2 22.5/22.2 Btu/h 49,600/48,400 76,800/75,800 76,800/75,800 kcal/h 12,500/12,200 19,400/19,100 19,400/19,100 kW 5.17/5.17 7.7/7.6 7.7/7.6 Power consumption 1a/1b White Colour Indoor m3/min 13 17 13 Airflow rate (H) unit 3 cfm 458 600 458 dB(A) 38/33 39/35 38/33 Sound level (H/L) 2 mm 195X 960X 680 195X 1,160X 680 195X 960X 680 Dimensions (HX WX D) kg 24 27 24 Machine weight 14 to 25 Certified operation range °CWB Ivory white Colour Outdoor Hermetically sealed scroll type Compressor Type unit 4.50 5.5 5.5 kW Motor output 4.1 (Charged for 30 m) 5.3 (Charged for 5 m) 5.3 (Charged for 5 m) kg Refrigerant charge (R-22) 60 60 dB(A) 54 Sound level 2 mm 1,345X 900X 320 1,220X 1,280X 690 1,220X 1,280X 690 Dimensions (HX WX D) kg 109 178 178 Machine weight -5 to 52 Certified operation range °CDB 21 to 46, -15 to 46 4 (Option installed) mm Piping Liquid (Flare) o/ 9.5 o/ 12.7 o/ 12.7 connections Gas mm o/ 25.4 (Flange) o/ 25.4 (Flange) o/ 19.1 (Flare) mm Drain Indoor unit I.D o/ 20X O.D o/ 26 I.D o/ 20X O.D o/ 26 I.D o/ 20X O.D o/ 26 ----------------Outdoor unit mm o/ 26.0 (Hole) m 50 (equivalent length 70 m) Max. interunit piping length 30 m Max. installation level difference Both liquid and gas piping Heat insulation Indoor unit Model Name Outdoor unit Power supply Cooling capacity 1a/1b 250 FHY60BVE × 4 R250KUY1 Model Name Power supply Cooling capacity 1a/1b Indoor unit Outdoor unit Power consumption 1a/1b Colour Fan Airflow rate (H) Indoor unit 3 External static pressure Sound level (H) 2 Dimensions (HX WX D) Machine weight Certified operation range Colour Outdoor Compressor Type unit Motor output Refrigerant charge (R-22) Sound level 2 Dimensions (HX WX D) Machine weight Certified operation range Piping Liquid (Flare) connections Gas (Flange) Drain Indoor unit Outdoor unit Max. interunit piping length Max. installation level difference Heat insulation kW Btu/h kcal/h kW m3/min cfm Pa(mmH2O) dB(A) mm kg °CWB kW kg dB(A) mm kg °CDB mm mm mm mm m m 200 250 200 FDYM04FAV1 × 2 FDYM05FAV1 × 2 FDYM03FAV1 × 3 R200KUY1 R250KUY1 R200KUY1 V1: 1 Phase, 220–240 V, 50 Hz Y1: 3 Phase, 380–415 V, 50 Hz 22.5/22.2 27.1/26.6 22.5/22.2 76,800/75,800 92,500/90,800 76,800/75,800 19,400/19,100 23,300/22,900 19,400/19,100 7.7/7.6 9.9/9.9 8.0/7.9 ---------26 35 20 917 1,235 706 98(10) 98(10) 98(10) 39 44 39 295X 1,500X 680 295X 1,500X 680 295X 1,100X 680 56 57 42 14 to 25 Ivory white Hermetically sealed scroll type 5.5 9.0 5.5 5.3 (Charged for 5 m) 5.7 (Charged for 5 m) 5.3 (Charged for 5 m) 60 61 60 1,220X 1,280X 690 1,440X 1,280X 690 1,220X 1,280X 690 178 202 178 -5 to 52 o/ 12.7 o/ 15.9 o/ 12.7 o/ 25.4 o/ 28.6 o/ 25.4 o/ 25I.D.,o/ 32O.D. o/ 25I.D.,o/ 32O.D. o/ 25I.D.,o/ 32O.D. ------------------------50 (equivalent length 70 m) 30 Both liquid and gas piping Note : Models R200KU and R250KU are recommended for commercial facilities. 1 Rated cooling capacities are based on the following conditions: 1a Suction temp., 27°CDB, 19.5°CWB; outdoor temp. 35°CDB. Equiv. refrigeration piping, 5 m (horizontal). 1b Suction temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB. Equiv. refrigeration piping, 5 m (horizontal). 2 Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions. 3 Values shown are for a single unit only. 27.1/26.6 92,500/90,800 23,300/22,900 9.7/9.7 16 564 38/33 195X 1,160X 680 26 9.0 5.7 (Charged for 5 m) 61 1,440X 1,280X 690 202 o/ 15.9 o/ 28.6 (Flange) I.D o/ 20X O.D o/ 26 --------- Note : Models R200KU and R250KU are recommended for commercial facilities. 1 Rated cooling capacities are based on the following conditions: 1a Indoor temp., 27°CDB, 19.5°CWB; outdoor temp. 35°CDB. Equiv. refrigeration piping, 5 m (horizontal). 1b Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB. Equiv. refrigeration piping, 5 m (horizontal). (R71LU-R140LU is 7.5 m.) 2 Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions. 3 Values shown are for a single unit only. 4 This value is for when year-round cooling kit (option) is installed. 47 48 CEILING MOUNTED CASSETTE TYPE Outdoor unit Power supply Cooling capacity 1a/1b kW Btu/h kcal/h kW Btu/h kcal/h kW kW Heating capacity 2 Cooling 1a/1b Heating 2 Colour Unit Decoration panel m3/min Airflow rate (H) cfm dB(A) Sound level (H/L) 3 mm Dimensions Unit (H×W×D) mm Decoration panel kg Machine weight Unit kg Decoration panel °CWB Cooling Certified operation range Heating °CDB Colour Compressor Type Motor output kW Power consumption Indoor unit Outdoor unit 35 FHYC35KVE Indoor unit Model Name Refrigerant charge (R-22) Sound level (Cooling/Heating) 3 Dimensions (H×W×D) Machine weight Cooling Certified operation range Heating Piping Liquid (Flare) connections Gas (Flare) Drain Indoor unit Outdoor unit Max. interunit piping length Max. installation level difference Heat insulation kg 71 100 125 140 FHYC71KVE FHYC100KVE FHYC125KVE FHYC140KVE RY100LUV1 RY71LUV1 RY35FV1A RY50GAV1A RY60GAV1A RY125LUY1 RY140LUY1 RY71LUY1 RY100LUY1 VE: 1 Phase 220–240/220 V, 50/60 Hz V1: 1 Phase 220–240 V, 50 Hz Y1: 3 Phase, 380–415 V, 50 Hz 3.79/3.75 5.27/5.2 6.24/6.15 7.8/7.7 10.5/10.4 13.0/12.8 14.5/14.2 12,900/12,800 18,000/17,800 21,300/21,000 26,600/26,200 35,700/35,300 44,500/43,600 49,400/48,400 3,260/3,230 4,530/4,470 5,370/5,290 6,700/6,600 9,000/8,900 11,200/11,000 12,500/12,200 4.22 5.8 7.0 7.9 11.2 14.2 16.3 14,400 19,800 23,900 27,000 38,100 48,400 56,000 3,630 4,990 6,020 6,800 9,600 12,200 14,000 1.51/1.50 1.92/1.91 2.35/2.33 3.01 /3.01 (V1), 2.99/2.99 (Y1) 3.93 /3.93 (V1), 3.88/3.88 (Y1) 4.89/4.89 4.95/4.95 1.37 1.68 2.26 2.84 (V1), 2.82 (Y1) 3.64 (V1), 3.60 (Y1) 4.68 4.84 ---------White 14 15 19 19 28 33 35 494 529 670 670 988 1,164 1,235 33/29 33/29 35/30 35/30 39/34 42/36 44/37 230×840×840 230×840×840 230×840×840 230×840×840 288×840×840 288×840×840 288×840×840 40×950×950 40×950×950 40×950×950 40×950×950 40×950×950 40×950×950 40×950×950 24 24 24 24 28 28 28 5 5 5 5 5 5 5 14 to 23 12 to 25 15 to 28 15 to 27 Ivory white Hermetically sealed rotary type Hermetically sealed scroll type 1.3 1.7 2.2 2.24 3.00 3.75 4.50 1.12 1.55 1.75 2.8 3.7 3.7 4.1 (Charged for 10 m) (Charged for 10 m) (Charged for 5 m) (Charged for 30 m) (Charged for 30 m) (Charged for 30 m) (Charged for 30 m) 47/48 dB(A) 540×750×270 mm 41 kg °CDB °CWB o/ 6.4 mm o/ 12.7 mm mm I.Do/ 25×O.Do/ 32 o/ 18.0 (Hole) mm 20 m m 50 FHYC50KVE 49/51 685×800×300 51 19.4 to 46 -10 to 15.5 o/ 6.4 o/ 15.9 I.Do/ 25×O.Do/ 32 o/ 18.0 (Hole) 15 60 FHYC60KVE 54/54 685×880×350 75 48/49 49/52 49/52 54/56 770×900×320 1,170×900×320 1,170×900×320 1,345×900×320 73 (V1), 72 (Y1) 89 (V1), 86 (Y1) 101 112 -5 to 46 -10 to 15 o/ 6.4 o/ 9.5 o/ 9.5 o/ 9.5 o/ 9.5 o/ 15.9 o/ 15.9 o/ 19.1 o/ 19.1 o/ 19.1 I.Do/ 25×O.Do/ 32 I.Do/ 25×O.Do/ 32 I.Do/ 25×O.Do/ 32 I.Do/ 25×O.Do/ 32 I.Do/ 25×O.Do/ 32 o/ 18.0 (Hole) o/ 26.0 (Hole) o/ 26.0 (Hole) o/ 26.0 (Hole) o/ 26.0 (Hole) 30 50 (equivalent length 70 m) 30 Both liquid and gas piping CEILING SUSPENDED TYPE Indoor unit Model Name Outdoor unit Power supply Cooling capacity 1a/1b Heating capacity 2 Power consumption Indoor unit Outdoor unit Cooling 1a/1b Heating 2 Colour Airflow rate (H) Sound level (H/L) 3 Dimensions (HX WX D) Machine weight Cooling Certified operation range Heating Colour Compressor Type Motor output Refrigerant charge (R-22) Sound level (Cooling/Heating) 3 Dimensions (HX WX D) Machine weight Cooling Certified operation range Heating Piping Liquid (Flare) connections Gas (Flare) Drain Indoor unit Outdoor unit Max. interunit piping length Max. installation level difference Heat insulation 35 FHY35BVE 71 100 125 FHY71BVE FHY100BVE FHY125BVE RY71LUV1 RY100LUV1 RY35FV1A RY50GAV1A RY60GAV1A RY125LUY1 RY71LUY1 RY100LUY1 VE: 1 Phase 220–240/220 V, 50/60 Hz V1: 1 Phase 220–240 V, 50 Hz Y1: 3 Phase, 380–415 V, 50 Hz kW 3.5/3.5 5.0/4.85 6.3/6.15 7.8/7.7 10.5/10.4 13.0/12.8 12,100/11,900 16,900/16,600 21,400/21,000 26,600/26,200 35,700/35,300 44,500/43,600 Btu/h 3,040/3,000 4,260/4,200 5,390/5,300 6,700/6,600 9,000/8,900 11,200/11,000 kcal/h 4.1 5.5 7.1 7.9 11.2 14.2 kW 14,000 18,800 24,200 27,000 38,100 48,400 Btu/h 3,520 4,750 6,100 6,800 9,600 12,200 kcal/h 2.17/2.16 3.14/3.12 kW 1.58/1.57 3.04/3.04 (V1), 3.02/3.02 (Y1) 3.82/3.82 (V1), 3.77/3.77 (Y1) 4.85/4.85 kW 1.37 1.96 2.94 2.98 (V1), 2.95 (Y1) 3.69 (V1), 3.64 (Y1) 4.77 White m3/min 13 13 16 17 24 30 cfm 458 458 564 600 847 1,059 dB(A) 37/32 38/33 38/33 39/35 42/37 44/39 mm 195X 960X 680 195X 960X 680 195X 1,160X 680 195X 1,160X 680 195X 1,400X 680 195X 1,590X 680 kg 23 24 26 27 32 35 °CWB 14 to 23 12 to 25 °CDB 15 to 28 15 to 27 Ivory white Hermetically sealed rotary type Hermetically sealed scroll type kW 1.3 1.7 2.2 2.24 3.00 3.75 1.12 1.55 1.75 2.8 3.7 3.7 kg (Charged for 10 m) (Charged for 10 m) (Charged for 5 m) (Charged for 30 m) (Charged for 30 m) (Charged for 30 m) dB(A) mm kg °CDB °CWB mm mm mm mm m m 47/48 540X 750X 270 41 o/ 6.4 o/ 12.7 I.D o/ 20X O.D o/ 26 o/ 18.0 (Hole) 20 50 FHY50BVE 49/51 685X 800X 300 51 19.4 to 46 -10 to 15.5 o/ 6.4 o/ 15.9 I.D o/ 20X O.D o/ 26 o/ 18.0 (Hole) 15 60 FHY60BVE 54/54 685X 880X 350 75 49/52 49/52 1,170X 900X 320 1,170X 900X 320 89 (V1), 86 (Y1) 101 -5 to 46 -10 to 15 o/ 6.4 o/ 9.5 o/ 9.5 o/ 9.5 o/ 15.9 o/ 15.9 o/ 19.1 o/ 19.1 I.D o/ 20X O.D o/ 26 I.D o/ 20X O.D o/ 26 I.D o/ 20X O.D o/ 26 I.D o/ 20X O.D o/ 26 o/ 18.0 (Hole) o/ 26.0 (Hole) o/ 26.0 (Hole) o/ 26.0 (Hole) 30 50 (equivalent length 70 m) 30 Both liquid and gas piping Note : 1 Rated cooling capacities are based on the following conditions: 1a Indoor temp., 27°CDB, 19.5°CWB; outdoor temp. 35°CDB. Equiv. refrigeration piping, 5 m (horizontal). 1b Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB. Equiv. refrigeration piping, 5 m (horizontal). (RY71LU-RY140LU is 7.5 m.) 2 Rated heating capacities are based on the following conditions: Indoor temp., 20°CDB; outdoor temp., 7°CDB, 6°CWB. Equiv. refrigeration piping, 5 m (horizontal). (RY71LU-RY140LU is 7.5 m.) 3 Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions. 49 48/49 770X 900X 320 73 (V1), 72 (Y1) CEILING SUSPENDED CASSETTE TYPE Model Name Outdoor unit Power supply Cooling capacity 1a/1b Heating capacity 2 Power consumption Indoor unit 71 FUY71FJV1 RY71LUV1 RY71LUY1 Indoor unit Cooling 1a/1b Heating 2 Colour Airflow rate (H) Sound level (H/L) 3 Dimensions (HX WX D) Machine weight Cooling Certified operation range Heating Colour Outdoor Compressor Type unit Motor output Refrigerant charge (R-22) Sound level (Cooling/Heating) 3 Dimensions (HX WX D) Machine weight Cooling Certified operation range Heating Piping Liquid (Flare) connections Gas (Flare) Drain Indoor unit Outdoor unit Max. interunit piping length Max. installation level difference Heat insulation kW Btu/h kcal/h kW Btu/h kcal/h kW kW m3/min cfm dB(A) mm kg °CWB °CDB kW kg dB(A) mm kg °CDB °CWB mm mm mm mm m m 100 125 FUY100FJV1 FUY125FJV1 RY100LUV1 RY125LUY1 RY100LUY1 V1: 1 Phase 220–240 V, 50 Hz Y1: 3 Phase, 380–415 V, 50 Hz 7.8/7.7 13.0/12.8 10.5/10.4 26,600/26,200 44,500/43,600 35,700/35,300 6,700/6,600 11,200/11,000 9,000/8,900 7.9 11.2 14.2 27,000 38,100 48,400 6,800 12,200 9,600 4.90/4.90 3.02/3.02 (V1), 3.00/3.00 (Y1) 3.99/3.99 (V1), 3.94/3.94 (Y1) 4.61 2.87 (V1), 2.84 (Y1) 3.66 (V1), 3.62 (Y1) White 19 29 32 670 1,023 1,129 40/35 43/38 44/39 165X 895X 895 230X 895X 895 230X 895X 895 25 31 31 12 to 25 15 to 27 Ivory white Hermetically sealed scroll type 2.24 3.00 3.75 2.8 (Charged for 30 m) 3.7 (Charged for 30 m) 3.7 (Charged for 30 m) 48/49 49/52 49/52 770X 900X 320 1,170X 900X 320 1,170X 900X 320 73 (V1), 72 (Y1) 89 (V1), 86 (Y1) 101 -5 to 46 -10 to 15 o/ 9.5 o/ 9.5 o/ 9.5 o/ 15.9 o/ 19.1 o/ 19.1 I.D o/ 20X O.D o/ 26 o/ 26.0 (Hole) o/ 26.0 (Hole) o/ 26.0 (Hole) 50 (equivalent length 70 m) 30 Both liquid and gas piping CEILING MOUNTED CASSETTE CORNER TYPE Model Name Power supply Cooling capacity 1a/1b Heating capacity 2 Indoor unit Outdoor unit kW Btu/h kcal/h kW Btu/h kcal/h kW kW Cooling 1a/1b Heating 2 Colour Unit Indoor Decoration panel unit m3/min Airflow rate (H) cfm dB(A) Sound level (H/L) 3 mm Dimensions Unit (HX WX D) mm Decoration panel kg Machine weight Unit kg Decoration panel °CWB Cooling Certified °CDB operation range Heating Colour Outdoor Compressor Type unit Motor output kW kg Refrigerant charge (R-22) dB(A) Sound level (Cooling/Heating) 3 mm Dimensions (HX WX D) kg Machine weight °CDB Cooling Certified °CWB operation range Heating mm Piping Liquid (Flare) connections mm Gas (Flare) mm Drain Indoor unit mm Outdoor unit m Max. interunit piping length m Max. installation level difference Heat insulation Power consumption 35 FHYK35FJV1 45 FHYK45FJV1 60 FHYK60FJV1 RY35FV1A RY50GAV1A RY60GAV1A 71 FHYK71FJV1 RY71LUV1 RY71LUY1 V1: 1 Phase, 220–240 V, 50 Hz Y1: 3 Phase, 380–415 V, 50 Hz 3.5/3.5 5.0/4.85 6.3/6.15 7.8/7.7 12,100/11,900 16,900/16,600 21,400/21,000 26,600/26,200 3,040/3,000 4,260/4,200 5,390/5,300 6,700/6,600 4.1 5.5 7.1 7.9 14,000 18,800 24,000 27,000 3,520 4,740 6,080 6,800 1.47/1.46 1.95/1.94 2.87/2.85 3.01/3.01 (V1), 2.99/2.99 (Y1) 1,25 1.72 2.65 2.91 (V1), 2.88 (Y1) ---------White 12 12 17 17 423 423 600 600 39/33 39/34 41/36 41/36 215X 1,110X 710 215X 1,110X 710 215X 1,310X 710 215X 1,310X 710 70X 1,240X 800 70X 1,240X 800 70X 1,440X 800 70X 1,440X 800 30 31 33 33 8.5 8.5 9.5 9.5 14 to 23 12 to 25 15 to 27 15 to 28 Ivory white Hermetically sealed rotary type Hermetically sealed scroll type 1.3 1.7 2.2 2.24 1.12 (Charged for 10 m) 1.55 (Charged for 10 m) 1.75 (Charged for 5 m) 2.8 (Charged for 30 m) 47/48 49/51 54/54 48/49 540×750×270 685×800×300 685×880×350 770×900×320 41 51 75 73 (V1), 72 (Y1) 19.4 to 46 -5 to 46 -10 to 15.5 -10 to 15 o/ 6.4 o/ 6.4 o/ 6.4 o/ 9.5 o/ 12.7 o/ 15.9 o/ 15.9 o/ 15.9 I.D o/ 25×O.D o/ 32 I.D o/ 25×O.D o/ 32 I.D o/ 25×O.D o/ 32 I.D o/ 25×O.D o/ 32 o/ 18.0 (Hole) o/ 18.0 (Hole) o/ 18.0 (Hole) o/ 26.0 (Hole) 20 30 50 (equivalent length 70 m) 15 30 Both liquid and gas piping Note : 1 Rated cooling capacities are based on the following conditions: 1a Indoor temp., 27°CDB, 19.5°CWB; outdoor temp. 35°CDB. Equiv. refrigeration piping, 5 m (horizontal). 1b Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB. Equiv. refrigeration piping, 5 m (horizontal). (RY71LU-RY125LU is 7.5 m.) 2 Rated heating capacities are based on the following conditions: Indoor temp., 20°CDB; outdoor temp., 7°CDB, 6°CWB. Equiv. refrigeration piping, 5 m (horizontal). (RY71LU-RY125LU is 7.5 m.) 3 Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions. 50 FLOOR STANDING TYPE CEILING MOUNTED BUILT-IN TYPE 35 FHYB35FV1 Indoor unit Model Name Outdoor unit Power supply Cooling capacity 1a/1b kW Btu/h kcal/h kW Btu/h kcal/h kW kW Heating capacity 2 Cooling 1a/1b Heating 2 Colour Unit Decoration panel m3/min Airflow rate (H) cfm dB(A) Sound level (H/L) 3 mm Dimensions Unit (HX WX D) mm Decoration panel kg Machine weight Unit kg Decoration panel °CWB Cooling Certified operation range Heating °CDB Colour Compressor Type Motor output kW Power consumption Indoor unit Outdoor unit kg Refrigerant charge (R-22) Sound level (Cooling/Heating) Dimensions (HX WX D) Machine weight Cooling Certified operation range Heating Piping Liquid (Flare) connections Gas (Flare) Drain Indoor unit Outdoor unit Max. interunit piping length Max. installation level difference Heat insulation 3 dB(A) mm kg °CDB °CWB mm mm mm mm m m 71 100 125 FHYB71FV1 FHYB100FV1 FHYB125FV1 RY71LUV1 RY100LUV1 RY35FV1A RY50GAV1A RY60GAV1A RY125LUY1 RY71LUY1 RY100LUY1 V1: 1 Phase, 220–240 V, 50 Hz Y1: 3 Phase, 380–415 V, 50 Hz 3.5/3.5 5.0/4.85 6.3/6.15 7.8/7.7 10.5/10.4 13.0/12.8 12,100/11,900 16,900/16,600 21,400/21,000 26,600/26,200 35,700/35,300 44,500/43,600 3,040/3,000 4,260/4,200 5,390/5,300 6,700/6,600 9,000/8,900 11,200/11,000 4.1 5.5 7.1 7.9 11.2 14.2 14,000 18,800 24,200 27,000 38,100 48,400 3,520 4,750 6,100 6,800 9,600 12,200 3.07/3.07 (V1), 3.05/3.05 (Y1) 3.92/3.92 (V1), 3.87/3.87 (Y1) 1.53/1.52 1.97/1.96 2.91/2.89 4.67/4.67 1.34 1.92 2.71 3.06 (V1), 3.03 (Y1) 3.75 (V1), 3.70 (Y1) 4.63 ---------White 11.5 14 17 19 27 35 405 494 600 670 953 1,235 38/32 39/34 41/35 41/35 41/35 44/38 300X 700X 800 300X 700X 800 300X 1,000X 800 300X 1,000X 800 300X 1,400X 800 300X 1,400X 800 55X 880X 500 55X 880X 500 55X 1,100X 500 55X 1,100X 500 55X 1,500X 500 55X 1,500X 500 30 31 41 41 51 52 3.5 3.5 4.5 4.5 6.5 6.5 14 to 23 12 to 25 15 to 28 15 to 27 Ivory white Hermetically sealed rotary type Hermetically sealed scroll type 1.3 1.7 2.2 2.24 3.00 3.75 1.12 1.55 1.75 2.8 3.7 3.7 (Charged for 10 m) (Charged for 10 m) (Charged for 5 m) (Charged for 30 m) (Charged for 30 m) (Charged for 30 m) 47/48 540X 750X 270 41 o/ 6.4 o/ 12.7 I.D o/ 25X O.D o/ 32 o/ 18.0 (Hole) 20 45 FHYB45FV1 49/51 685X 800X 300 51 19.4 to 46 -10 to 15.5 o/ 6.4 o/ 15.9 I.D o/ 25X O.D o/ 32 o/ 18.0 (Hole) 15 60 FHYB60FV1 54/54 685X 880X 350 75 48/49 770X 900X 320 73 (V1), 72 (Y1) 49/52 49/52 1,170X 900X 320 1,170X 900X 320 89 (V1), 86 (Y1) 101 -5 to 46 -10 to 15 o/ 6.4 o/ 9.5 o/ 9.5 o/ 9.5 o/ 15.9 o/ 15.9 o/ 19.1 o/ 19.1 I.D o/ 25X O.D o/ 32 I.D o/ 25X O.D o/ 32 I.D o/ 25X O.D o/ 32 I.D o/ 25X O.D o/ 32 o/ 18.0 (Hole) o/ 26.0 (Hole) o/ 26.0 (Hole) o/ 26.0 (Hole) 30 50 (equivalent length 70 m) 30 Both liquid and gas piping Indoor unit Outdoor unit Power Supply Cooling capacity 1a/1b Heating capacity 2 Power consumption Indoor unit Cooling 1a/1b Heating 2 Colour Airflow rate (H) Sound level (H/L) 3 Dimensions (HX WX D) Machine weight Cooling Certified operation range Heating Colour Outdoor Compressor Type unit Motor output Refrigerant charge (R-22) Sound level (Cooling/Heating) 3 Dimensions (HX WX D) Machine weight Cooling Certified operation range Heating Piping Liquid (Flare) connections Gas (Flare) Drain Indoor unit Outdoor unit Max. interunit piping length Max. installation level difference Heat insulation 51 Outdoor unit Cooling capacity 1a/1b kW Btu/h kcal/h kW Btu/h kcal/h kW kW 71 FAY71LVE RY71LUV1 RY71LUY1 VE: 1 Phase, 220–240/220 V, 50/60 Hz 7.8/7.7 26,600/26,200 6,700/6,600 7.9 27,000 6,800 2.92/2.92 (V1), 2.90/2.90 (Y1) 2.85 (V1), 2.82 (Y1) m3/min cfm dB(A) mm kg °CWB °CDB 19 670 43/37 290X 1,050X 230 13 kW kg dB(A) mm kg °CDB °CWB mm mm mm mm m m 2.24 2.8 (Charged for 30 m) 48/49 770X 900X 320 73 (V1), 72 (Y1) o/ 9.5 o/ 15.9 I.D o/ 13X O.D o/ 18 o/ 26.0 (Hole) 100 FAY100FAVE RY100LUV1 RY100LUY1 V1: 1 Phase, 220–240 V, 50 Hz Y1: 3 Phase, 380–415 V, 50 Hz 10.5/10.4 35,700/35,300 9,000/8,900 11.2 38,100 9,600 3.82/ 3.82 (V1), 3.77/ 3.77 (Y1) 3.66 (V1), 3.61 (Y1) White 23 811 45/41 360X 1,570X 200 26 12 to 25 15 to 27 Ivory white Hermetically sealed scroll type 3.00 3.7 (Charged for 30 m) 49/52 1,170X 900X 320 89 (V1), 86 (Y1) -5 to 46 -10 to 15 o/ 9.5 o/ 19.1 I.D o/ 20X O.D o/ 26 o/ 26.0 (Hole) 50 (equivalent length 70 m) 30 Both liquid and gas piping Note : 1 Rated cooling capacities are based on the following conditions: (FHYB) 1aSuction temp., 27°CDB, 19.5°CWB; outdoor temp. 35°CDB. Equiv. refrigeration piping, 5 m (horizontal). 1b Suction temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB. Equiv. refrigeration piping, 5 m (horizontal). (RY71LU-RY125LU is 7.5 m.) (FAY) 1aIndoor temp., 27°CDB, 19.5°CWB; outdoor temp. 35°CDB. Equiv. refrigeration piping, 5 m (horizontal). 1b Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB. Equiv. refrigeration piping, 7.5 m (horizontal). 2 Rated heating capacities are based on the following conditions: (FHYB) Suction temp., 20°CDB; outdoor temp., 7°CDB, 6°CWB. Equiv. refrigeration piping, 5 m (horizontal). (RY71LU-RY125LU is 7.5 m.) (FAY) Indoor temp., 20°CDB; outdoor temp., 7°CDB, 6°CWB. Equiv. refrigeration piping, 7.5 m (horizontal). 3 Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions. kW Btu/h kcal/h kW Btu/h kcal/h kW kW Heating capacity 2 Power consumption Indoor unit Cooling 1a/1b Heating 2 Colour Airflow rate (H) Sound level (H/L) 3 Dimensions (HX WX D) Machine weight Cooling Certified operation range Heating Colour Outdoor Compressor Type unit Motor output Refrigerant charge (R-22) Sound level (Cooling/Heating) 3 Dimensions (HX WX D) Machine weight Cooling Certified operation range Heating Liquid (Flare) Piping connections Gas (Flare) Drain Indoor unit Outdoor unit Max. interunit piping length Max. installation level difference Heat insulation m3/min cfm dB(A) mm kg °CWB °CDB kW kg dB(A) mm kg °CDB °CWB mm mm mm mm m m 71 100 FVY71LAVE FVY100LAVE RY71LUV1 RY100LUV1 RY71LUY1 RY100LUY1 VE: 1 Phase, 220–240/220 V, 50/60 Hz V1: 1 Phase, 220–240 V, 50 Hz 7.8/7.7 10.5/10.4 26,600/26,200 35,700/35,300 6,700/6,600 9,000/8,900 7.9 11.2 27,000 38,100 6,800 9,600 3.12/3.12 (V1), 3.10/3.10 (Y1) 3.95/3.95 (V1), 3.90/3.90 (Y1) 3.00 (V1), 2.97 (Y1) 3.75 (V1), 3.70 (Y1) White 18 28 635 988 41/35 46/40 1,850X 600X 270 1,850X 600X 350 39 46 12 to 25 15 to 27 Ivory white Hermetically sealed scroll type 2.24 3.00 2.8 (Charged for 30 m) 3.7 (Charged for 30 m) 48/49 49/52 770X 900X 320 1,170X 900X 320 73 (V1), 72 (Y1) 89 (V1), 86 (Y1) -5 to 46 -10 to 15 o/ 9.5 o/ 9.5 o/ 15.9 o/ 19.1 I.D o/ 20X O.D o/ 26 I.D o/ 20X O.D o/ 26 o/ 26.0 (Hole) o/ 26.0 (Hole) 50 (equivalent length 70 m) 30 Both liquid and gas piping 125 FVY125LAVE RY125LUY1 Y1: 3 Phase, 380–415 V, 50 Hz 13.0/12.8 44,500/43,600 11,200/11,000 14.2 48,400 12,200 4.99/4.99 4.73 32 1,129 49/43 1,850X 600X 350 47 3.75 3.7 (Charged for 30 m) 49/52 1,170X 900X 320 101 o/ 9.5 o/ 19.1 I.D o/ 20X O.D o/ 26 o/ 26.0 (Hole) DUCT CONNECTION LOW STATIC PRESSURE TYPE Indoor unit Model Name WALL MOUNTED TYPE Model Name Indoor unit Model Name Outdoor unit Power supply Cooling capacity 1a/1b kW Btu/h kcal/h kW Btu/h kcal/h kW kW Heating capacity 2 Power consumption Indoor unit Cooling 1a/1b Heating 2 Colour Airflow rate (H) Fan Outdoor unit External static pressure Driving system Sound level (H/L) 3 Dimensions(HX WX D) Machine weight Cooling Certified operation range Heating Colour Compressor Type Motor output dB(A) mm kg °CWB °CDB kW kg Refrigerant charge (R-22) Sound level (Cooling/Heating) Dimensions (HX WX D) Machine weight Cooling Certified operation range Heating Piping Liquid (Flare) connections Gas (Flare) Drain Indoor unit Outdoor unit Max. interunit piping length Max. installation level difference Heat insulation m3/min cfm Pa(mmH2O) 3 dB(A) mm kg °CDB °CWB mm mm mm mm m m 35 FDYB35KAVE 50 FDYB50KAVE 60 FDYB60KAVE 71 FDYB71KAVE RY71LUV1 RY35FV1A RY50GAV1A RY60GAV1A RY71LUY1 VE: 1 Phase, 220–240/220 V, 50/60 Hz V1: 1 Phase, 220–240 V, 50 Hz Y1: 3 Phase, 380–415 V, 50 Hz 3.79/3.75 5.27/5.20 6.24/6.15 7.8/7.7 12,900/12,800 18,000/17,800 21,300/21,000 26,600/26,200 3,260/3,230 4,530/4,470 5,370/5,290 6,700/6,600 4.22 5.80 7.0 7.9 14,400 23,900 27,000 19,800 3,630 4,990 6,020 6,800 1.51/1.50 2.01/2.00 2.38/2.36 3.08/3.08 (V1), 3.06/3.06 (Y1) 1.33 1.78 2.29 2.91 (V1), 2.88 (Y1) ---------13 18 460 635 20 (2) Direct drive (2 speed) 41/ 38 43/ 40 260X 900X 580 260X 1,300X 580 22 23 31 14 to 23 12 to 25 15 to 28 15 to 27 Ivory white Hermetically sealed rotary type Hermetically sealed scroll type 1.3 1.7 2.2 2.24 1.12 1.55 1.75 2.8 (Charged for 10 m) (Charged for 10 m) (Charged for 5 m) (Charged for 30 m) 47/48 540X 750X 270 41 49/51 685X 800X 300 51 19.4 to 46 -10 to 15.5 o/ 6.4 o/ 15.9 54/54 685X 880X 350 75 o/ 6.4 o/ 12.7 o/ 6.4 o/ 15.9 48/49 770X 900X 320 73 (V1), 72 (Y1) -5 to 46 -10 to 15 o/ 9.5 o/ 15.9 3/4B o/ 18.0 (Hole) 20 o/ 18.0 (Hole) Note : 1 Rated cooling capacities are based on the following conditions: (FVY) 1aIndoor temp., 27°CDB, 19.5°CWB; outdoor temp. 35°CDB. Equiv. refrigeration piping, 5 m (horizontal). 1b Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB. Equiv. refrigeration piping, 7.5 m (horizontal). (FDYB) 1aSuction temp., 27°CDB, 19.5°CWB; outdoor temp. 35°CDB. Equiv. refrigeration piping, 5 m (horizontal). 1b Suction temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB. Equiv. refrigeration piping, 5 m (horizontal). 2 Rated heating capacities are based on the following conditions: (FVY) Indoor temp., 20°CDB; outdoor temp., 7°CDB, 6°CWB. Equiv. refrigeration piping, 7.5 m (horizontal). (FDYB) Suction temp., 20°CDB; outdoor temp., 7°CDB, 6°CWB. Equiv. refrigeration piping, 5 m (horizontal). 3 Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions. o/ 18.0 (Hole) 30 15 o/ 26.0 (Hole) 50 (equivalent length 70 m) 30 Both liquid and gas piping 52 Simultaneous operation system TWIN & TRIPLE & DOUBLE TWIN MULTI DUCT CONNECTION MIDDLE STATIC PRESSURE TYPE Model Name Outdoor unit Power supply Cooling capacity 1a/1b kW Btu/h kcal/h kW Btu/h kcal/h kW kW Heating capacity 2 Power consumption Indoor unit 71 FDYM03FAV1 RY71LUV1 RY71LUY1 Indoor unit Cooling 1a/1b Heating 2 Colour Fan Airflow rate (H) m3/min cfm External static pressure Pa(mmH2O) dB(A) Sound level (H) 3 mm Dimensions (HX WX D) kg Machine weight °CWB Cooling Certified operation range Heating °CDB Colour Outdoor Compressor Type unit Motor output kW kg Refrigerant charge (R-22) dB(A) Sound level (Cooling/Heating) 3 mm Dimensions (HX WX D) kg Machine weight °CDB Cooling Certified operation range Heating °CWB mm Piping Liquid (Flare) connections mm Gas (Flare) mm Drain Indoor unit mm Outdoor unit m Max. interunit piping length m Max. installation level difference Heat insulation 100 125 140 FDYM04FAV1 FDYM05FAV1 FDYM06FAV1 RY100LUV1 RY125LUY1 RY140LUY1 RY100LUY1 V1: 1 Phase, 220–240 V, 50 Hz Y1: 3 Phase, 380–415 V, 50 Hz 7.8/7.7 10.5/10.4 13.0/12.8 14.5/14.2 26,600/26,200 35,700/35,300 44,500/43,600 49,400/48,400 6,700/6,600 9,000/8,900 11,200/11,000 12,500/12,200 7.9 11.2 14.2 16.3 27,000 38,100 48,400 56,000 6,800 9,600 12,200 14,000 3.19/3.19 (V1), 3.17/3.17 (Y1) 4.00/4.00 (V1), 3.95/3.95 (Y1) 4.99/4.99 5.10/5.10 2.95 (V1), 2.92 (Y1) 3.91 (V1), 3.86 (Y1) 4.75 4.96 ---------20 26 35 37 706 917 1,235 1,306 98 (10) 98 (10) 98 (10) 98 (10) 39 39 44 46 295X 1,100X 680 295X 1,500X 680 295X 1,500X 680 295X 1,500X 680 42 56 57 57 12 to 25 15 to 27 Ivory white Hermetically sealed scroll type 2.24 3.00 3.75 4.50 2.8 (Charged for 30 m) 3.7 (Charged for 30 m) 3.7 (Charged for 30 m) 4.1 (Charged for 30 m) 48/49 49/52 49/52 54/56 770X 900X 320 1,170X 900X 320 1,170X 900X 320 1,345X 900X 320 73 (V1), 72 (Y1) 89 (V1), 86 (Y1) 101 112 -5 to 46 -10 to 15 o/ 9.5 o/ 9.5 o/ 9.5 o/ 9.5 o/ 15.9 o/ 19.1 o/ 19.1 o/ 19.1 I.Do/ 25X O.Do/ 32 I.Do/ 25X O.Do/ 32 I.Do/ 25X O.Do/ 32 oI.Do/ 25X O.Do/ 32 o/ 26.0 (Hole) o/ 26.0 (Hole) o/ 26.0 (Hole) o/ 26.0 (Hole) 50 (equivalent length 70 m) 30 Both liquid and gas piping DUCT CONNECTION HIGH STATIC PRESSURE TYPE Model Name Power supply Cooling capacity 1a/1b kW Btu/h kcal/h kW Btu/h kcal/h kW kW Heating capacity 2 Power consumption Indoor unit Cooling 1a/1b Heating 2 Colour Airflow rate (H) Fan Outdoor unit 140 FDY06KAY1 RY140LUY1 Indoor unit Outdoor unit External static pressure Driving system Sound level (H) 3 Dimensions(HX WX D) 5 Machine weight Cooling Certified operation range Heating Colour Compressor Type Motor output dB(A) mm kg °CWB °CDB kW kg Refrigerant charge (R-22) Sound level (Cooling/Heating) Dimensions (HX WX D) Machine weight Cooling Certified operation range Heating Piping Liquid (Flare) connections Gas Drain Indoor unit Outdoor unit Max. interunit piping length Max. installation level difference Heat insulation m3/min cfm Pa(mmH2O) 3 dB(A) mm kg °CDB °CWB mm mm mm mm m m 200 250 400 500 FDY08KAY1 FDY10KAY1 FDY15KAY1 FDY20KAY1 RY200KUY1 RY250KUY1 RY200KUY1X 2 RY250KUY1X 2 Y1: 3 phase, 380–415 V (4 wires), 50 Hz 14.5/14.2 22.5/22.2 27.6/27.1 44.0/43.5 53.9/53.0 49,500/48,500 76,800/75,700 94,200/92,500 150,000/148,000 184,000/181,000 12,500/12,220 19,300/19,100 23,700/23,300 37,800/37,400 46,400/45,600 15.3 23.2 29.5 44.8 56.8 52,200 100,700 153,000 194,000 79,200 13,200 20,000 25,400 38,500 48,800 5.14/5.14 7.2/7.1 9.3/9.2 14.4/14.2 18.5/18.3 4.54 6.1 8.8 12.2 17.6 --------52 68 83 136 166 1,835 2,400 2,929 4,800 5,859 118 (12) 147 (15) 108 (11) Belt drive 51 53 58 60 450X 1,130X 850 500X 1,130X 850 500X 1,330X 850 625X 1,620X 850 625X 1,980X 850 80 94 105 161 187 12 to 25 14 to 25 15 to 27 Ivory white Hermetically sealed scroll type 4.5 5.5 9.0 5.5 X 2 9.0 X 2 4.1 4.0 5.5 4.0 5.5 (Charged for 5 m) X 2 (Charged for 5 m) X 2 (Charged for 30 m) (Charged for 5 m) (Charged for 5 m) 54/56 60/62 61/63 60/62 4 61/63 4 1,345X 900X 320 1,220X 1,280X 690 1,440X 1,280X 690 (1,220X 1,280X 690) X 2 (1,440X 1,280X 690) X 2 112 180 206 180 X 2 206 X 2 -5 to 46 0 to 50 0 to 50 -10 to 15 -10 to 15 -10 to 15 o/ 15.9 X 2 o/ 12.7 X 2 o/ 12.7 o/ 15.9 o/ 9.5 o/ 28.6 X 2 (Flange) o/ 25.4 X 2 (Flange) o/ 25.4 (Flange) o/ 28.6 (Flange) o/ 19.1 (Flare) 1B 3/4B --------o/ 26.0 (Hole) 50 (equivalent length 70 m) 30 Both liquid and gas piping Note : Models RY200KU and RY250KU are recommended for commercial facilities. 1 Rated cooling capacities are based on the following conditions: 1a Suction temp., 27°CDB, 19.5°CWB; outdoor temp. 35°CDB. Equiv. refrigeration piping, 5 m (horizontal). 1b Suction temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB. Equiv. refrigeration piping, 5 m (horizontal). (RY71LU-RY140LU is 7.5 m.) 2 Rated heating capacities are based on the following conditions: Suction temp., 20°CDB; outdoor temp., 7°CDB, 6°CWB. Equiv. refrigeration piping, 5 m (horizontal). (RY71LU-RY140LU is 7.5 m.) 3 Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions. 4 Specification for outdoor unit is for a single unit only. 5 Without control box. 53 CEILING MOUNTED CASSETTE TYPE Indoor unit Model Name Outdoor unit Power supply Cooling capacity 1a/1b Heating capacity 2 kW Btu/h kcal/h kW Btu/h kcal/h kW kW Cooling 1a/1b Power consumption Heating 2 Colour Unit Indoor Decoration panel unit 3 m3/min Airflow rate (H) cfm dB(A) Sound level (H/L) 4 mm Dimensions Unit (HX WX D) Decoration panel mm kg Machine Unit weight Decoration panel kg °CWB Cooling Certified operation range Heating °CDB Colour Outdoor Compressor Type unit Motor output kW Refrigerant charge (R-22) kg Sound level (Cooling/Heating) 4 dB(A) mm Dimensions (HX WX D) kg Machine weight °CDB Cooling Certified operation range Heating °CWB mm Piping Liquid (Flare) connections Gas mm mm Drain Indoor unit Outdoor unit mm m Max. interunit piping length m Max. installation level difference Heat insulation Indoor unit Model Name Outdoor unit Power supply Cooling capacity 1a/1b Heating capacity 2 71 100 125 140 200 250 FHYC35KVEX 2 FHYC50KVEX 2 FHYC60KVEX 2 FHYC71KVEX 2 FHYC100KVEX 2 FHYC125KVEX 2 RY71LUV1 RY100LUV1 RY125LUY1 RY140LUY1 RY200KUY1 RY250KUY1 RY71LUY1 RY100LUY1 VE: 1 Phase, 220–240/220 V, 50/60 Hz V1: 1 Phase, 220–240 V, 50 Hz Y1: 3 Phase, 380–415 V, 50 Hz 7.8/7.7 10.5/10.4 13.0/12.8 14.5/14.2 22.5/22.2 27.1/26.6 26,600/26,200 35,700/35,300 44,500/43,600 49,400/48,400 76,800/75,800 92,500/90,800 6,700/6,600 9,000/8,900 11,200/11,000 12,500/12,200 19,400/19,100 23,300/22,900 7.9 11.2 14.2 16.3 22.7 28.4 27,000 38,100 48,400 56,000 77,500 97,000 6,800 9,600 12,200 14,000 19,500 24,400 4.94/4.94 4.95/4.95 7.7/7.6 9.7/9.7 3.11/3.11 (V1), 3.09/3.09 (Y1) 3.98/3.98 (V1), 3.93/3.93 (Y1) 2.94 (V1), 2.92 (Y1) 3.69 (V1), 3.65 (Y1) 4.73 4.84 6.5 9.2 ------------White 14 15 19 19 28 33 494 529 670 670 988 1,164 33/29 33/29 35/30 35/30 39/34 42/36 230X 840X 840 230X 840X 840 230X 840X 840 230X 840X 840 288X 840X 840 288X 840X 840 40X 950X 950 40X 950X 950 40X 950X 950 40X 950X 950 40X 950X 950 40X 950X 950 24 24 24 24 28 28 5 5 5 5 5 5 12 to 25 14 to 25 15 to 27 15 to 27 Ivory white Hermetically sealed scroll type 2.24 3.00 3.75 4.50 5.5 9.0 2.8 3.7 3.7 4.1 4.0 5.5 (Charged for 30 m) (Charged for 30 m) (Charged for 30 m) (Charged for 30 m) (Charged for 5 m) (Charged for 5 m) 48/49 770X 900X 320 73 (V1), 72 (Y1) o/ 9.5 o/ 15.9 (Flare) I.D o/ 25X O.D o/ 32 o/ 26.0 (Hole) 49/52 49/52 54/56 1,170X 900X 320 1,170X 900X 320 1,345X 900X 320 89 (V1), 86 (Y1) 101 112 -5 to 46 -10 to 15 o/ 9.5 o/ 9.5 o/ 9.5 o/ 19.1 (Flare) o/ 19.1 (Flare) o/ 19.1 (Flare) I.D o/ 25X O.D o/ 32 I.D o/ 25X O.D o/ 32 I.D o/ 25X O.D o/ 32 o/ 26.0 (Hole) o/ 26.0 (Hole) o/ 26.0 (Hole) 50 (equivalent length 70 m) 30 Both liquid and gas piping 60/62 61/63 1,220X 1,280X 690 1,440X 1,280X 690 180 206 0 to 50 -10 to 15 o/ 12.7 o/ 15.9 o/ 25.4 (Flange) o/ 28.6 (Flange) I.D o/ 25X O.D o/ 32 I.D o/ 25X O.D o/ 32 ----------------- 140 FHYC50KVEX 3 RY140LUY1 kW Btu/h kcal/h kW Btu/h kcal/h kW kW Cooling 1a/1b Power consumption Heating 2 Colour Unit Indoor Decoration panel unit 3 m3/min Airflow rate (H) cfm dB(A) Sound level (H/L) 4 mm Dimensions Unit (HX WX D) Decoration panel mm kg Machine Unit weight Decoration panel kg °CWB Cooling Certified operation range Heating °CDB Colour Outdoor Compressor Type unit Motor output kW Refrigerant charge (R-22) kg Sound level (Cooling/Heating) 4 dB(A) mm Dimensions (HX WX D) kg Machine weight °CDB Cooling Certified operation range Heating °CWB mm Piping Liquid (Flare) connections Gas mm mm Drain Indoor unit Outdoor unit mm m Max. interunit piping length m Max. installation level difference Heat insulation 200 200 250 FHYC71KVEX 3 FHYC50KVEX 4 FHYC60KVEX 4 RY200KUY1 RY200KUY1 RY250KUY1 VE: 1 Phase, 220–240/220 V, 50/60 Hz Y1: 3 Phase, 380–415 V, 50 Hz 14.5/14.2 22.5/22.2 22.5/22.2 27.1/26.6 49,400/48,400 76,800/75,800 76,800/75,800 92,500/90,800 12,500/12,200 19,400/19,100 19,400/19,100 23,300/22,900 16.3 22.7 22.7 28.4 56,000 77,500 77,500 97,000 14,000 19,500 19,500 24,400 4.95/4.95 7.7/7.6 7.7/7.6 9.7/9.7 4.84 6.5 6.5 9.2 ------------White 15 19 15 19 529 670 529 670 33/29 35/30 33/29 35/30 230X 840X 840 230X 840X 840 230X 840X 840 230X 840X 840 40X 950X 950 40X 950X 950 40X 950X 950 40X 950X 950 24 24 24 24 5 5 5 5 12 to 25 14 to 25 15 to 27 15 to 27 Ivory white Hermetically sealed scroll type 4.50 5.5 5.5 9.0 4.1 (Charged for 30 m) 4.0 (Charged for 5 m) 4.0 (Charged for 5 m) 5.5 (Charged for 5 m) 54/56 60/62 60/62 61/63 1,345X 900X 320 1,220X 1,280X 690 1,220X 1,280X 690 1,440X 1,280X 690 112 180 180 206 -5 to 46 0 to 50 -10 to 15 -10 to 15 o/ 12.7 o/ 12.7 o/ 15.9 o/ 9.5 o/ 25.4 (Flange) o/ 25.4 (Flange) o/ 28.6 (Flange) o/ 19.1 (Flare) I.D o/ 25X O.D o/ 32 I.D o/ 25X O.D o/ 32 I.D o/ 25X O.D o/ 32 I.D o/ 25X O.D o/ 32 ------------------------o/ 26.0 (Hole) 50 (equivalent length 70 m) 30 Both liquid and gas piping Note : Models RY200KU and RY250KU are recommended for commercial facilities. 1 Rated cooling capacities are based on the following conditions: 1a Indoor temp., 27°CDB, 19.5°CWB; outdoor temp. 35°CDB. Equiv. refrigeration piping, 5 m (horizontal). 1b Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB. Equiv. refrigeration piping, 5 m (horizontal). (RY71LU-RY140LU is 7.5 m.) 2 Rated heating capacities are based on the following conditions: Indoor temp., 20°CDB; outdoor temp., 7°CDB, 6°CWB. Equiv. refrigeration piping, 5 m (horizontal). (RY71LU-RY140LU is 7.5 m.) 3 Values shown are for a single unit only. 4 Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions. 54 Simultaneous operation system TWIN & TRIPLE & DOUBLE TWIN MULTI CEILING SUSPENDED TYPE DUCT CONNECTION LOW STATIC PRESSURE TYPE 71 100 125 140 200 250 Indoor unit FHY35BVE × 2 FHY50BVE × 2 FHY60BVE × 2 FHY71BVE × 2 FHY100BVE × 2 FHY125BVE × 2 Model RY71LUV1 RY100LUV1 Name Outdoor unit RY125LUY1 RY140LUY1 RY200KUY1 RY250KUY1 RY71LUY1 RY100LUY1 Power supply VE: 1 Phase, 220–240/220 V, 50/60 Hz V1: 1 Phase, 220–240 V, 50 Hz Y1: 3 Phase, 380–415 V, 50 Hz Cooling capacity 1a/1b kW 7.8/7.7 10.5/10.4 13.0/12.8 14.5/14.2 22.5/22.2 27.1/26.6 Btu/h 26,600/26,200 35,700/35,300 44,500/43,600 49,400/48,400 76,800/75,800 92,500/90,800 kcal/h 6,700/6,600 9,000/8,900 11,200/11,000 12,500/12,200 19,400/19,100 23,300/22,900 Heating capacity 2 kW 7.9 11.2 14.2 16.3 22.7 28.4 27,000 38,100 48,400 56,000 77,500 97,000 Btu/h kcal/h 6,800 9,600 12,200 14,000 19,500 24,400 3.14/3.14 (V1) 3.87/3.87 (V1) Power 1a/1b 9.7/9.7 4.91/4.91 5.10/5.10 7.7/7.6 kW Cooling consumption 3.12/3.12 (Y1) 3.82/3.82 (Y1) 9.2 3.08 (V1), 3.05 (Y1) 3.74 (V1),3.69 (Y1) 4.83 4.99 kW 6.5 Heating 2 White Colour Indoor 13 13 16 17 24 30 m3/min Airflow rate (H) unit 3 458 458 564 600 847 1,059 cfm 37/32 38/33 38/33 39/35 42/37 44/39 dB(A) Sound level (H/L) 4 195X 960X 680 195X 960X 680 195X 1,160X 680 195X 1,160X 680 195X 1,400X 680 195X 1,590X 680 mm Dimensions (HX WX D) 23 24 26 27 32 35 kg Machine weight °CWB 12 to 25 14 to 25 Cooling Certified operation range Heating °CDB 15 to 27 15 to 27 Ivory white Colour Outdoor Hermetically sealed scroll type Compressor Type unit 2.24 3.00 3.75 4.50 5.5 9.0 Motor output kW 2.8 3.7 3.7 4.1 4.0 5.5 Refrigerant charge (R-22) kg (Charged for 30 m) (Charged for 30 m) (Charged for 30 m) (Charged for 30 m) (Charged for 5 m) (Charged for 5 m) Sound level (Cooling/Heating) 4 dB(A) mm Dimensions (HX WX D) kg Machine weight °CDB Cooling Certified operation range Heating °CWB mm Piping Liquid (Flare) connections Gas mm mm Drain Indoor unit Outdoor unit mm m Max. interunit piping length m Max. installation level difference Heat insulation 48/49 770X 900X 320 73 (V1), 72 (Y1) o/ 9.5 o/ 15.9 (Flare) I.D o/ 20X O.D o/ 26 o/ 26.0 (Hole) 49/52 49/52 54/56 1,170X 900X 320 1,170X 900X 320 1,345X 900X 320 89 (V1), 86 (Y1) 101 112 -5 to 46 -10 to 15 o/ 9.5 o/ 9.5 o/ 9.5 o/ 19.1 (Flare) o/ 19.1 (Flare) o/ 19.1 (Flare) I.D o/ 20X O.D o/ 26 I.D o/ 20X O.D o/ 26 I.D o/ 20X O.D o/ 26 o/ 26.0 (Hole) o/ 26.0 (Hole) o/ 26.0 (Hole) 50 (equivalent length 70 m) 30 Both liquid and gas piping 60/62 61/63 1,220X 1,280X 690 1,440X 1,280X 690 180 206 0 to 50 -10 to 15 o/ 12.7 o/ 15.9 o/ 25.4 (Flange) o/ 28.6 (Flange) I.D o/ 20X O.D o/ 26 I.D o/ 20X O.D o/ 26 ----------------- Model Name Power supply Cooling capacity 1a/1b Indoor unit Outdoor unit Heating capacity 2 Power consumption Indoor unit 3 Cooling 1a/1b Heating 2 Colour Airflow rate (H) Fan External static pressure Sound level (H) 4 Dimensions (HX WX D) Machine weight Cooling Certified operation range Heating Colour Outdoor Compressor Type unit Motor output Refrigerant charge (R-22) Sound level (Cooling/Heating) 4 Dimensions (HX WX D) Machine weight Cooling Certified operation range Heating Piping Liquid connections Gas Drain Indoor unit Outdoor unit Max. interunit piping length Max. installation level difference Heat insulation kW Btu/h kcal/h kW Btu/h kcal/h kW kW m3/min cfm Pa(mmH2O) dB(A) mm kg °CWB °CDB kW kg dB(A) mm kg °CDB °CWB mm mm mm mm m m 200 200 250 FDYB50KAVE × 4 FDYB71KAVE × 3 FDYB60KAVE × 4 RY200KUY1 RY200KUY1 RY250KUY1 VE: 1 Phase, 220–240/220 V, 50/60 Hz Y1: 3 Phase, 380–415 V, 50 Hz 22.5/22.2 22.5/22.2 27.1/26.6 76,800/75,800 76,800/75,800 92,500/90,800 19,400/19,100 19,400/19,100 23,300/22,900 22.7 22.7 28.4 77,500 77,500 97,000 19,500 19,500 24,400 7.7/7.6 9.7/9.7 7.7/7.6 6.5 9.2 6.5 ––– 13 18 18 458 635 635 20 (2) 41 43 43 260X 900X 580 260X 1,300X 580 260X 1,300X 580 23 31 31 14 to 25 14 to 25 14 to 25 15 to 27 15 to 27 15 to 27 Ivory white Hermetically sealed scroll type 5.5 5.5 9.0 4.0 (Charged for 5 m) 4.0 (Charged for 5 m) 5.5 (Charged for 5 m) 60/62 60/62 61/63 1,220X 1,280X 690 1,220X 1,280X 690 1,440X 1,280X 690 180 206 180 0 to 50 -10 to 15 12.7 (Flare) 12.7 (Flare) 15.9 (Flare) 25.4 (Flange) 25.4 (Flange) 28.6 (Flange) 3/4B ––– 50 (equivalent length 70 m) 30 Both liquid and gas piping DUCT CONNECTION MIDDLE STATIC PRESSURE TYPE Model Indoor unit Name Outdoor unit Power supply Cooling capacity 1a/1b Heating capacity 2 Cooling 1a/1b Power consumption Heating 2 Colour Indoor Airflow rate (H) unit 3 140 FHY50BVE × 3 RY140LUY1 kW Btu/h kcal/h kW Btu/h kcal/h kW kW m3/min cfm dB(A) mm kg °CWB °CDB Sound level (H/L) 4 Dimensions (HX WX D) Machine weight Cooling Certified operation range Heating Colour Outdoor Compressor Type unit Motor output kW Refrigerant charge (R-22) kg Sound level (Cooling/Heating) 4 dB(A) mm Dimensions (HX WX D) kg Machine weight °CDB Cooling Certified operation range Heating °CWB mm Piping Liquid (Flare) connections Gas mm mm Drain Indoor unit Outdoor unit mm m Max. interunit piping length m Max. installation level difference Heat insulation 200 200 250 FHY71BVE × 3 FHY50BVE × 4 FHY60BVE × 4 RY200KUY1 RY200KUY1 RY250KUY1 VE: 1 Phase, 220–240/220 V, 50/60 Hz Y1: 3 Phase, 380–415 V, 50 Hz 14.5/14.2 22.5/22.2 22.5/22.2 27.1/26.6 49,400/48,400 76,800/75,800 76,800/75,800 92,500/90,800 12,500/12,200 19,400/19,100 19,400/19,100 23,300/22,900 22.7 22.7 28.4 16.3 77,500 77,500 97,000 56,000 19,500 19,500 24,400 14,000 7.7/7.6 7.7/7.6 9.7/9.7 5.10/5.10 6.5 6.5 9.2 4.99 White 17 16 13 13 600 564 458 458 39/35 38/33 38/33 38/33 195X 1,160X 680 195X 1,160X 680 195X 960X 680 195X 960X 680 27 26 24 24 12 to 25 14 to 25 15 to 27 15 to 27 Ivory white Hermetically sealed scroll type 4.50 5.5 5.5 9.0 4.1 (Charged for 30 m) 4.0 (Charged for 5 m) 4.0 (Charged for 5 m) 5.5 (Charged for 5 m) 54/56 60/62 60/62 61/63 1,345X 900X 320 1,220X 1,280X 690 1,220X 1,280X 690 1,440X 1,280X 690 112 180 180 206 -5 to 46 0 to 50 -10 to 15 -10 to 15 o/ 12.7 o/ 12.7 o/ 15.9 o/ 9.5 o/ 25.4 (Flange) o/ 25.4 (Flange) o/ 28.6 (Flange) o/ 19.1 (Flare) I.D o/ 20X O.D o/ 26 I.D o/ 20X O.D o/ 26 I.D o/ 20X O.D o/ 26 I.D o/ 20X O.D o/ 26 ------------------------o/ 26.0 (Hole) 50 (equivalent length 70 m) 30 Both liquid and gas piping Note : Models RY200KU and RY250KU are recommended for commercial facilities. 1 Rated cooling capacities are based on the following conditions: 1a Indoor temp., 27°CDB, 19.5°CWB; outdoor temp. 35°CDB. Equiv. refrigeration piping, 5 m (horizontal). 1b Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB. Equiv. refrigeration piping, 5 m (horizontal). (RY71LU-RY140LU is 7.5 m.) 2 Rated heating capacities are based on the following conditions: Indoor temp., 20°CDB; outdoor temp., 7°CDB, 6°CWB. Equiv. refrigeration piping, 5 m (horizontal). (RY71LU-RY140LU is 7.5 m.) 3 Values shown are for a single unit only. 4 Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions. 55 Model Indoor unit Name Outdoor unit Power supply Cooling capacity 1a/1b Heating capacity 2 Power consumption Indoor unit 3 Cooling 1a/1b Heating 2 Colour Fan Airflow rate (H) kW Btu/h kcal/h kW Btu/h kcal/h kW kW m3/min cfm External static pressure Pa(mmH2O) dB(A) Sound level (H) 4 mm Dimensions (HX WX D) kg Machine weight °CWB Cooling Certified operation range Heating °CDB Colour Outdoor Compressor Type unit kW Motor output kg Refrigerant charge (R-22) dB(A) Sound level (Cooling/Heating) 4 mm Dimensions (HX WX D) kg Machine weight °CDB Cooling Certified operation range Heating °CWB mm Piping Liquid (Flare) connections mm Gas mm Drain Indoor unit mm Outdoor unit m Max. interunit piping length m Max. installation level difference Heat insulation 200 250 200 FDYM04FAV1 × 2 FDYM05FAV1 × 2 FDYM03FAV1 × 3 RY200KUY1 RY250KUY1 RY200KUY1 V1: 1 Phase, 220–240 V, 50 Hz Y1: 3 Phase, 380–415 V, 50 Hz 22.5/22.2 27.1/26.6 22.5/22.2 76,800/75,800 92,500/90,800 76,800/75,800 19,400/19,100 23,300/22,900 19,400/19,100 22.7 28.4 22.7 77,500 97,000 77,500 19,500 24,400 19,500 7.7/7.6 9.9/9.9 8.0/7.9 6.5 9.2 6.8 ---------26 35 20 917 1,235 706 98 (10) 98 (10) 98 (10) 39 44 39 295X 1,500X 680 295X 1,500X 680 295X 1,100X 680 56 57 42 14 to 25 15 to 27 Ivory white Hermetically sealed scroll type 5.5 9.0 5.5 4.0 (Charged for 5 m) 5.5 (Charged for 5 m) 4.0 (Charged for 5 m) 60/62 61/63 60/62 1,220X 1,280X 690 1,440X 1,280X 690 1,220X 1,280X 690 180 206 180 0 to 50 -10 to 15 o/ 12.7 o/ 15.9 o/ 12.7 o/ 25.4 (Flange) o/ 28.6 (Flange) o/ 25.4 (Flange) I.D o/ 25X O.D o/ 32 I.D o/ 25X O.D o/ 32 I.D o/ 25X O.D o/ 32 ------------------------50 (equivalent length 70 m) 30 Both liquid and gas piping Note : Models RY200KU and RY250KU are recommended for commercial facilities. 1 Rated cooling capacities are based on the following conditions: 1a Suction temp., 27°CDB, 19.5°CWB; outdoor temp. 35°CDB. Equiv. refrigeration piping, 5 m (horizontal). 1b Suction temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB. Equiv. refrigeration piping, 5 m (horizontal) 2 Rated heating capacities are based on the following conditions: Suction temp., 20°CDB; outdoor temp., 7°CDB, 6°CWB. Equiv. refrigeration piping, 5 m (horizontal) 3 Values shown are for a single unit only. 4 Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions. 56 CEILING MOUNTED CASSETTE CORNER TYPE Indoor unit Kit name Name of option CEILING MOUNTED CASSETTE TYPE Name of option Remark Decoration panel Sealing member for air discharge outlet Panel spacer Fresh air intake kit1 Chamber Without the T-joint pipe and fan type With the T-joint pipe,without fan Direct installation type Chamber connection kit2 High-efficiency filter (Colorimetric method 65%) (Colorimetric method 90%) Replacement (Colorimetric method 65%) high-efficiency filter (Colorimetric method 90%) High-efficiency filter chamber Replacement long-life filter Ultra long-life filter Replacement ultra long-life filter Branch duct chamber Remote controller Wired type3 Wireless type Wired LCD remote controller with weekly schedule timer Central remote controller4 Unified ON/OFF controller4 Schedule timer4 intelligent Touch Controller4 Adaptor for wiring5 Wiring adaptor for electrical appendices5 Interface adaptor for SkyAir series Installation box for adaptor PCB Kit name Heat pump Cooling only FHC35K/50K/60K FHYC35K/50K/60K/71K FHYC100K/125K/140K FHYC100K/125K/140K FHYC35K/50K/60K/71K BYC125K-W1 KDBHJ55K160 KDBP55H160WA KDDP55D160 KDDP55D160K KDDJ55X160 KKSJ55K160 KAFP556D80 KAFP556D160 KAFP557D80 KAFP557D160 KAFP552H80 KAFP552H160 KAFP553H80 KAFP553H160 KDDFP55D160 KAFJ551K160 KAFP55D160 KAFJ55K160H KDJ55K80 KDJ55K160 BRC1C61 BRC7C612W BRC1D61 DCS302CA61 DCS301BA61 DST301BA61 DCS601C51 KRP1BA57 KRP4AA53 DTA102A52 KRP1B98 BYC125K-W1 KDBHJ55K160 KDBP55H160WA KDDP55D160 KDDP55D160K KDDJ55X160 KKSJ55K160 KAFP556D80 KAFP556D160 KAFP557D80 KAFP557D160 KAFP552H80 KAFP552H160 KAFP553H80 KAFP553H160 KDDFP55D160 KAFJ551K160 KAFP55D160 KAFJ55K160H KDJ55K80 KDJ55K160 BRC1C61 BRC7C613W BRC1D61 DCS302CA61 DCS301BA61 DST301BA61 DCS601C51 KRP1BA57 KRP4AA53 DTA102A52 KRP1B98 Note: 1 Refer to page 14 for the details. 2 Required for installing high-efficiency or ultra long-life filter. 3 Wiring for wired remote controller to be procured locally. 4 This optional accessory requires DTA102A52. 5 Installation box for adaptor PCB (KRP1B98) is necessary. CEILING SUSPENDED TYPE Kit name Heat pump Cooling only FH(Y)35B FH(Y)50B FH(Y)60B FHY71B FHY100B FHY125B FHY35B FHY50B FHY60B FHY71B FHY100B FHY125B Replacement long-life filter Resin net KAFJ501D56 KAFJ501D80 KAFJ501D112 KAFJ501D160 KAFJ501D56 KAFJ501D80 KAFJ501D112 KAFJ501D160 Drain-up kit KDU50B50VE KDU50B71VE KDU50B125VE KDU50B125VE KDU50B50VE KDU50B71VE L-type piping kit (for upward direction) KHFJ5F50 KHFJ5F60 KHFJ5F80 KHFJ5F160 KHFJ5F50 KHFJ5F60 KHFJ5F80 KHFJ5F160 Remote controller Wired type1 BRC1C61 BRC1C61 BRC7E63W Wireless type BRC7EA66 Wired LCD remote controller with weekly schedule timer BRC1D61 BRC1D61 Central remote controller2 DCS302CA61 DCS302CA61 2 Unified ON/OFF controller DCS301BA61 DCS301BA61 Schedule timer2 DST301BA61 DST301BA61 intelligent Touch Controller2 DCS601C51 DCS601C51 Adaptor for wiring KRP1BA54 KRP1BA54 Wiring adaptor for electrical appendices3 KRP4AA52 KRP4AA52 Interface adaptor for SkyAir series DTA102A52 DTA102A52 KRP1CA93 KRP1CA93 Installation box for adaptor PCB Name of option Remark Note: 1 Wiring for wired remote controller to be procured locally. 2 This optional accessory requires DTA102A52. 3 Installation box for adaptor PCB (KRP1CA93) is necessary. Kit name Remark Replacement long-life filter Sealing member for air discharge outlet1 Decoration panel for air discharge Vertical flap kit L-connection piping kit Remote controller Wired type2 Wireless type Wired LCD remote controller with weekly schedule timer Central remote controller3 Unified ON/OFF controller3 Schedule timer3 intelligent Touch Controller3 Wiring adaptor for electrical appendices4 Interface adaptor for SkyAir series Installation box for adaptor PCB Note: 1 Required at time of installation for setting two-way opposing air flow. 2 Wiring for wired remote controller to be procured locally. 3 This optional accessory requires DTA102A52. 4 Installation box for adaptor PCB (KRP1B97) is necessary. 57 Decoration panel Panel spacer Air discharge blind panel Replacement long-life filter Resin net Discharge grille Flexible duct with shutter Remote controller Wired type1 Wired LCD remote controller with weekly schedule timer Central remote controller2 Unified ON/OFF controller2 Schedule timer2 intelligent Touch Controller2 Adaptor for wiring (interlock for fresh air intake fan) Wiring adaptor for electrical appendices Interface adaptor for SkyAir series Cooling only FUY71FJ FUY100FJ/125FJ KAFJ495F140 KDBHJ49F80 KDBHJ49F140 KDBTJ49F80 KDBTJ49F140 KDGJ49F80 KDGJ49F140 KHFJ49F80 KHFJ49F140 BRC1C61 BRC7C529W BRC1D61 DCS302CA61 DCS301BA61 DST301BA61 DCS601C51 KRP4AA53 DTA102A52 KRP1B97 Heat pump FUY100FJ/125FJ KAFJ495F140 KDBHJ49F80 KDBHJ49F140 KDBTJ49F80 KDBTJ49F140 KDGJ49F80 KDGJ49F140 KHFJ49F80 KHFJ49F140 BRC1C61 BRC7C528W BRC1D61 DCS302CA61 DCS301BA61 DST301BA61 DCS601C51 KRP4AA53 DTA102A52 KRP1B97 FUY71FJ FHK35F/45F BYK45FJW1 KPBJ52F56W KDBJ52F56W KAFJ521F56 K-HV7AW KFDJ52F56 Heat pump FHYK60FJ/71FJ BYK71FJW1 KPBJ52F80W KDBJ52F80W KAFJ521F80 K-HV9AW KFDJ52F80 BRC1C61 BRC1D61 DCS302CA61 DCS301BA61 DST301BA61 DCS601C51 KRP1B51 KRP4AA51 DTA102A52 Cooling only FHK60F/FHYK71F BYK71FJW1 KPBJ52F80W KDBJ52F80W KAFJ521F80 K-HV9AW KFDJ52F80 BRC1C61 BRC1D61 DCS302CA61 DCS301BA61 DST301BA61 DCS601C51 KRP1B51 KRP4AA51 DTA102A52 FHYK35FJ/45FJ BYK45FJW1 KPBJ52F56W KDBJ52F56W KAFJ521F56 K-HV7AW KFDJ52F56 Note: 1Wiring for wired remote controller to be procured locally. 2 This optional accessory requires DTA102A52. CEILING MOUNTED BUILT-IN TYPE Kit name Heat pump Cooling only FHB35F/45F FHB60F/FHYB71F FHYB100F FHYB125F FHYB35F/45F FHYB60F/71F FHYB100F FHYB125F BYBS125DJW1 BYBS125DJW1 Decoration panel BYBS45DJW1 BYBS71DJW1 BYBS45DJW1 BYBS71DJW1 KTBJ25K160W KTBJ25K160W Service access panel KTBJ25K56W KTBJ25K80W KTBJ25K56W KTBJ25K80W KAFJ252L160 KAFJ252L160 (Colorimetric method 65%) KAFJ252L56 KAFJ252L80 KAFJ252L56 KAFJ252L80 High-efficiency filter KAFJ253L160 KAFJ253L160 (Colorimetric method 90%) KAFJ253L56 KAFJ253L80 KAFJ253L56 KAFJ253L80 KAFJ251K160 KAFJ251K160 Replacement long-life filter Resin net KAFJ251K56 KAFJ251K80 KAFJ251K56 KAFJ251K80 KAJ25L160D KAJ25L160D Filter chamber for bottom suction KAJ25L56D KAJ25L80D KAJ25L56D KAJ25L80D KAJ25L160B KAJ25L160B Filter chamber for rear suction KAJ25L56B KAJ25L80B KAJ25L56B KAJ25L80B KSA-25K160 KSA-25K160 Canvas duct KSA-25K56 KSA-25K80 KSA-25K56 KSA-25K80 (o/ 150) K-DG4DW K-DG5DW K-DG4DW K-DG5DW K-DG4DW K-DG5DW K-DG4DW K-DG5DW Discharge grille (o/ 200) K-DG7DW K-DG9DW K-DG7DW K-DG9DW K-DG7DW K-DG9DW K-DG7DW K-DG9DW K-DGC5D K-DGC4D K-DGC5D (o/ 150) K-DGC4D K-DGC4D K-DGC5D K-DGC4D K-DGC5D Discharge chamber (o/ 200) K-DGC7D K-DGC9D K-DGC7D K-DGC9D K-DGC7D K-DGC9D K-DGC7D K-DGC9D K-DDV20A K-DDV20A Branch duct o/ 200 o/ 150 (o/ 150) K-FDS151D (1 m) K-FDS152D (2 m) K-FDS153D (3 m) K-FDS151D (1 m) K-FDS152D (2 m) K-FDS153D (3 m) Flexible duct K-FDS154D (4 m) K-FDS155D (5 m) K-FDS156D (6 m) K-FDS154D (4 m) K-FDS155D (5 m) K-FDS156D (6 m) (o/ 200) K-FDS201D (1 m) K-FDS202D (2 m) K-FDS203D (3 m) K-FDS201D (1 m) K-FDS202D (2 m) K-FDS203D (3 m) K-FDS204D (4 m) K-FDS205D (5 m) K-FDS206D (6 m) K-FDS204D (4 m) K-FDS205D (5 m) K-FDS206D (6 m) KBBJ25K160 KBBJ25K160 Blind board KBBJ25K56 KBBJ25K80 KBBJ25K56 KBBJ25K80 KDAJ25K140 KDAJ25K140 Adaptor for discharge KDAJ25K56 KDAJ25K71 KDAJ25K56 KDAJ25K71 KDJ2507K160 KDJ2507K160 Flange for suction KDJ2507K56 KDJ2507K80 KDJ2507K56 KDJ2507K80 Remote controller Wired type1 BRC1C61 BRC1C61 Wired LCD remote controller with weekly schedule timer BRC1D61 BRC1D61 Central remote controller2 DCS302CA61 DCS302CA61 2 Unified ON/OFF controller DCS301BA61 DCS301BA61 Schedule timer2 DST301BA61 DST301BA61 intelligent Touch Controller2 DCS601C51 DCS601C51 Adaptor for wiring (interlock for fresh air intake fan) KRP1BA54 KRP1BA54 Wiring adaptor for electrical appendices3 KRP4AA51 KRP4AA51 Interface adaptor for SkyAir series DTA102A52 DTA102A52 Name of option Remark Note: 1Wiring for wired remote controller to be procured locally. 2This optional accessory requires DTA102A52. 3 Installation box for adaptor PCB (KRP1B97) is necessary. WALL MOUNTED TYPE Kit name Name of option FAY71L K-KDU572CVE Wired type1 Wireless type Wired LCD remote controller with weekly schedule timer Central remote controller Unified ON/OFF controller Schedule timer intelligent Touch Controller Wiring adaptor for electrical appendices (2) Interface adaptor for SkyAir series3 Installation box for adaptor PCB 1 3 Heat pump Cooling only Remark Drain-up kit Remote controller CEILING SUSPENDED CASSETTE TYPE Name of option Remark FAY100FA FAY71L K-KDU572CVE BRC7C611W BRC7EA618 BRC1C61 BRC7E619 BRC1C61 BRC7C610W BRC1D61 BRC1D61 DCS302CA61 DCS301BA61 DST301BA61 DCS601C51 KRP4AA51 3 FAY100FA DCS302CA61 2 DCS301BA61 2 DST301BA61 2 DCS601C51 2 KRP4AA51 DTA102A52 DCS302CA61 DCS301BA61 DST301BA61 DCS601C51 KRP4AA51 3 KRP4AA93 DCS302CA61 2 DCS301BA61 2 DST301BA61 2 DCS601C51 2 KRP4A51 DTA102A52 KRP4AA93 Wiring for wired remote controller to be procured locally. 2This optional accessory requires DTA102A52. Installation box for adaptor PCB (KRP4AA93) is necessary. FLOOR STANDING TYPE Kit name Name of option Remark Replacement long-life filter Wired LCD remote controller with weekly schedule timer Central remote controller1 Unified ON/OFF controller1 Schedule timer1 intelligent Touch Controller2 Remote controller for 2 remote control system Adaptor for wiring2 Group control adaptor2 Interface adaptor for SkyAir series Installation box for adaptor PCB Note: 1This optional accessory requires DTA102A52. 2 Installation box for adaptor PCB (KRP4A95) is necessary. Cooling only FVY71LA/100LA/125LA KAFJ95L160 BRC1D61 DCS302CA61 DCS301BA61 DST301BA61 DCS601C51 BRC1C61 KRP1BA57 KRP4AA52 DTA102A52 KRP4A95 Heat pump FVY71LA/100LA/125LA KAFJ95L160 BRC1D61 DCS302CA61 DCS301BA61 DST301BA61 DCS601C51 BRC1C61 KRP1BA57 KRP4AA52 DTA102A52 KRP4A95 58 DIME N S ION S (Unit: mm) Indoor unit CEILING MOUNTED CASSETTE TYPE Support for centralised control from else where., using a PC with a Web browser (Optional) Special Function 3 Sending of e-mail alerts to a specified address when malfunctions occur (Optional) Special Function 4 Built-in Ethernet port for connecting to the Internet or an intranet 55 840 55 295 240 Suspension bolt 4-M8 M10 5 8 260 270 315 840 80 2 100=200 85 4 1 40 350 2 Special Function 5 Simple interlock function Unification adapter for computerised control [DCS302A52] Special Function 4 Unified ON/OFF and status monitoring from the central monitoring panel 1500mm or more Required space 1500mm or more 1500mm or more 1500mm or more When the discharge grill is closeout,the required space is 200mm or more. A C FHYC100KVE-140KVE 288 298 195 14-M4 Hole (prepared hole) 40 50 155 165 40 350 B 230 240 165 55 Branch duct connection A 1 Liquid pipe connection 2 Gas pipe connection 3 Drain pipe connection 4 Power supply connection 195 150 Notes: 1 Location of unit's Name Plate For Main body: Switch Box Cover inside surface of suction grille. For decoration panel: Panel frame inside surface of suction grille. 2 When installing an optional accessory, refer to the installation drawings. For fresh air intake kit Inspection port is necessary. For high efficiency filter unit Inspection port is not necessary. 3 In case of using wireless remote controller, this position will be a signal receiver. Refer to the drawing of wireless remote controller in detail. 5 Remote control code and control wiring connection 6 Air discharge grille 7 Air suction grille 8 Port for water supply 9 Corner decoration cover 10 Drain hose CEILING SUSPENDED TYPE Special Function 3 1120 1160 FHY100BVE 1360 1400 FHY125BVE 1550 1590 KIS95 RG71A RG140A RG180A R71LU R100LU R125LU R140LU KIS95 ------- ------KKPJ5F180 ------------- ------KPW937A4 KKP937A4 1 ------- KHR58C21 KHD58C21A ------------- RY35F RY50G(A) R60G(A) KHD58D33 KRK5F80V1 KRK5F140V1 KRK5F160V1 ------- RY71LU RY100LU RY125LU RY140LU ------KKPJ5F180 ------------KHR58C21 KHD58C21A ------KHD58D33 ------- Note: 1One set includes 5 pieces for 5units. A (Hanging position) Hanging bolt 4-M8~M10 1 Position : Hole of wall for taking out in piping back (View from the front) 6 90 155 300 or more 55 (Required space) 13 Kit name Cooling only For twin multi For triple multi For double twin multi R200KU KHD58C23A KHR58P322H KHRJ5F224F R250KU KHD58C24A ------KHRJ5F280F Heat pump RY250KU RY200KU KHD58C23A KHD58C24A KHR58P322H ------KHRJ5F224F KHRJ5F280F 80 11 40 5 195 680 B 30 or more (Service space) 30 or more (Service space) 4 o/ 45 55 14 The Front Obstacle Floor side Brand name plate (Note.2) Drain pipe connection VP20 (For left piping) 6 80 3 Remark 105 15 225 275 ------- R71FU R100FU R125FU 10 300 275 Heat pump For height installaion Kit name R35G R50G R60G 65 60 8 Necessary for optional interface adaptor for SkyAir series (DTA112BA51) with the Intelligent Touch Controller. Cooling only 50 Position slit hole for taking out in piping back (View from the front) 127 HRV 5 (Required space) D -NET Plus Adapter Indoor Unit (option) [DCS601A52] 145 60 115 60 FHY71BVE 9 12 85 102 160 185 192 36 FH(Y)60BVE 1120 1160 Number of indoor unit expanded from 64 to 128. R25J R35J 170 105 90 18 17 16 142 58 65 960 135 920 40 FH(Y)50BVE From the floor side 2500 or more 155 Trouble reports Outdoor unit Drain piping kit Central drain plug Air direction adjustment grille Drain plug Refrigerant branch piping For twin multi For triple multi Year-round cooling kit 960 Special Function 1 Mobile Phone * Limitations apply to some models and functions. For details please contact your local sales office. Remark B 920 5 135 (Required space) D -NET A FH(Y)35BVE 210 • Connection to power consumption metre when using power proportional distribution function. (Optional) Forced OFF command from fire alarm monitoring panel 260 Pi Port Trouble reports Colour LCD Touch panel Icon display Multilingual (English, French, German, Spanish, Italian, or Chinese) 59 Branch duct connection 840 80 2 100=200 85 (Hanging position) Forced OFF contact input Special Function 3 Labor saving Overall energy savings Simplified BMS Refrigerant branch piping 12-M4 Hole (prepared hole) Remote monitoring and control RS-232C Name of option 55 [FHYC100KVE-140KVE] DCS601C51 Yearly schedule Power proportional distribution* (option) Auto cool/heat change-over Temperature Limitation Name of option For fresh air intake kit connection (direct installation type) B view Required space [FH(Y)C35KVE-71KVE] 55 FH(Y)C35KVE-71KVE PCMCIA Flash Memory Special Function 2 80 B 1000 or more Required space Special Function 2 60 160 420 A New communication functions in the user-friendly icon based multilingual controller simplity centralised control of the system • CSV output of power proportional distribution results (Optional) C view 4-4M4 Hole (prepared hole) 75 3 55 Doubling of number of connectable indoor unit by adding a D -NET PLUS adapter (Optional) Branch duct connection 7 A view Note: 1 This optional accessory requires DTA102A52. 2 This optional accessory requires DTA107A55. 3 This optional accessory requires KRP1B100. 4 Installation plate for adaptor PCB (KRP4A95) is necessary. 5 In case of using KRC17-2B or field supplied remote controller, 3-Minutes Timer (field supplied) is required. Special Function 1 C 165 155 6 40 350 80 BRC1C61 ------------BRC4C62 DCS302CA611 DCS301BA611 DST301BA611 DCS601C511 ------------KRP1BA573 KRP4AA533 ------DTA102A52 KRP1B100 ------------- 780 Suspension position 860~890 Ceiling opening 10 95 110 BRC1C61 ------------BRC4C62 DCS302CA611 DCS301BA611 DST301BA611 DCS601C511 ------------------KRP4AA514 ------DTA102A52 ------------------- 9 BRC1D61 ------- 80 2 100=200 85 150 BRC1C61 ------------BRC4C64 DCS302CA611 DCS301BA611 DST301BA611 DCS601C511 ------------------KRP4AA514 ------DTA102A52 ------------------- 300 or less 950 ------KRC47-2A KRC47-4A ------------------------------------------------------------------------------------- ------KRC47-3A KRC47-3A/ KRC17-2B 5 ------KRC47-5 ------------DCS302CA612 DCS301BA612 DST301BA612 DCS601C512 KRCS01-1B DTA107A55 ------------------------------------------- BRC1D61 ------- 950 860~890 Ceiling opening 680 Suspension position 420 125 150 B ------BRC1C61 ------KRC47-2A ------KRC47-4A ------BRC4C62 ------DCS302CA611 ------DCS301BA611 ------DST301BA611 DCS601C511 ------------------------------------KRP1BA54 ------KRP4AA52 3 ------KRP1B100 ------DTA102A52 ------------KDGF19A45 KDGF19A71 KDGF19A45 KDGF19A71 KKD19A1 KKD19A1 BRC1D61 ------- 750 Wired LCD remote controller Digital remote controller Digital remote controller for duct heater use Wireless remote controller Central remote controller Unified ON/OFF controller Schedule timer intelligent Touch Controller Remote sensor (for indoor temperature) Central control adaptor kit Adaptor for wiring Wiring adaptor for electrical appendices Switch box for adaptor kit Interface adaptor for SkyAir series Installation box for adaptor PCB Suction grille Drain pan cover ------KRC47-1A BRC1D61 ------- Note3. 06K/08K/ 10K Adjustable(0~550) ------KRC47-1A Wired LCD remote controller with weekly schedule timer Remote controller C 200 Remark 40 A 30 10 Name of option High static pressure type Heat pump Cooling only FD03K/ FD15K/ FDY06KA/08KA/ 04K/05K/ 20K 10KA/15KA/20KA Middle static pressure type Heat pump Cooling only FDMG71A/ FDYM03FA/ FDYM03FA/ 100A/125A/ 04FA/05FA/ 04FA/05FA/ 140A/180A 06FA 06FA Low static pressure type Heat pump Cooling only FDBG25A/ FDBG60A/ FDYB35KA/ FDYB60KA/ 35A/50A 71A 50KA 71KA 1000 or more Required space 165 DUCT CONNECTION TYPE 2 Notes: 1 Location of unit's Name Plate: Bottom of fan housing inside the suction grille. 2 In case of using wireless remote controller, this position will be a signal 3 The remote control code is the standard <about 3 m outside the machine> attached. (0.5 mm2 2 wicks O.D. 5.4) (It is attached to VRV.) 7 5 80 105 170 4 1 Air discharge grille 2 Air suction grille 3 Air filter 4 Gas pipe connection 5 Liquid pipe connection 6 Drain pipe conneciton 7 Earth terminal (inside the electric components box) (M4) 8 Suspension bracket 9 Backward piping and wiring connection opening lid 10 Upward piping and wiring connection opening lid 11 Right side pipe connection 12 Left back drain pipe connection 13 Left side drain pipe connection 14 Right side drain pipe connection 15 Hole of wall for taking out in piping back 16 Upward drain pipe connection 17 Upward gas pipe connection 18 Upward liquid pipe connection 60 DIME N S ION S (Unit: mm) CEILING MOUNTED BUILT-IN TYPE 1500mm or more Suspension bolt 65 895 1500mm or more When closing the discharge grill,the required space is 30mm or more.(Note3) 790 Susension position A 300 or more 52 1 F G H 58 40 165 FUY100FJV1/125FJV1 51 147 177 177 147 125 107 230 6 52 1 Liquid pipe connection 2 Gas pipe connection 3 Drain pipe connection 4 Air outlet 132 1000mm or more (Required space) Notes: 1 Location for manufacture's label: on bell mouth. 2 This is where the signal of wireless remote controller is received. Refer to the drawing of wireless remote controller in detail. 3 When closing the discharge grille (2 or 3 way discharge), direction of pipe connection will be limited, please refer to Installation manual. 5 Air suction grille 6 Corner decoration cover 7 Right pipe/wiring connection 140 170 200mm or more 1500mm or more 8 9 7 65 800 710 290 Dimensions for full open front panel 60 80 230 75 30 or more (Required space) 45 80 3 2 Piping direction 1 Name plate Note)2 50 or more 61 215 50 or more B C D E F G FH(Y)K35.45F(J)V1 1150 1200 1110 FH(Y)K60.71F(J)V1 1350 1400 1310 2 230=460 720 1440 6-M4 hole 260 Note. 2: Location of unit's Name plate For main body: Bottom part of fan housing inside of Air suction grille. For decoration panel: Service lid face inside of Air suction grille. When installing an optional accessory, refer to the installation drawings. For discharge grille For frexible duct For panel spacer For air discharge blind panel Inspection port is not necessary 520 1240 4-M4 hole (Requred space) 104 894 2500 or more For installation in high spaces 52 Outside line Notes: Location of unit's of NAME Plate: Right side surface of casing 2 In case of using wireless remote controller, this position will be a signal receiver. Refer to the drawing of wireless remote controller in detail. 80 hole 1 1 Liquid pipe connection 2 Gas pipe connection 3 Drain pipe connection 4 Wire intake 5 Wire intake for remote control cord 6 Grounding terminal (M4 in switch box) 7 Air discharge grille 8 Air suction grille 9 Long life air filter 10 Suspension bracket 105 170 10000 or more E Front discharge duct connection position (Note.2) Suspension bolt 4-M8~M10 Required space 120 100 20 140 D A 65 14.5 10 B (Ceiling opening) G 7 120 or less 1050 44 5 Piping direction (Requred space) 45 20 8 4-M4 hole 9 C 150 250 300 160 230 Fresh air intake position 280 125 100 Approx.400 232 F 190 350 (Suspension position) 500 Piping direction 200mm or more 20mm or more 250 65 Liquid pipe connection Gas pipe connection Drain pipe connection Wire intake for remote control cord Wire intake Drain hole Air filter [FAY71LVE] Required space 4 20 1 2 3 4 5 6 7 C View H (Suspension position) 215 A (Suspension position) Notes: 1 Location of unit's Name Plate: Fan housing surface inside of filter. 2 When installing an optional accessory, refer to the installation drawings. 3 Refer to the separate drawing when installing the duct. WALL MOUNTED TYPE 3 6 20 Fresh air intake position 7 10 Accessory drain elbow 67 5 600 125 (Knockout hole) A View 148 760 (Ceiling opening) 160 P.C.D FH(Y)B35FV1/45FV1 FH(Y)B60FV1/71FV1 44 2 1 B View 6-M5 hole (Circumference) 8 Rear pipe/wiring connection 9 Pipe through cover CEILING MOUNTED CASSETTE CORNER TYPE 5 L J K H G 6 65=390 750 650 628 4 150=600 11 65=715 1050 950 927 6 150=900 FHYB100FV1/125FV1 16 65=1040 1450 1328 1328 9 150=1350 18-M5 hole 50 or more (Required space) E 80 20 D G 80 F B 16 E A FUY71FJV1 Height of suspension bracket 4 A B C D E F FH(Y)B35FV1/45FV1 700 485 460 3 150=450 760 800 FH(Y)B60FV1/71FV1 1000 785 760 5 150=750 1060 1100 FHYB100FV1/125FV1 1400 1185 1160 7 150=1050 1460 1500 A G Suspension bolt Sustion air intake position when installing the duct (Note.3) L (Ceiling opening) 630 (Suspension position) 145 3 H 145 185 D C (Ceiling opening) 80 8 110 110 462 30 180 F C 4 J K E 7 5 6 83 109 9 46 2 Service space 895 790 Susension position 2 5 B 45 57 10 Drain pipe can be raised up to 350mm from the top surface of the product. Brand name plate (Note)2) 45 115~255 B A C 1500mm or more 2 65=130 10 117 3 1 67 150 200 10 300 245 215 150 135 163 1500mm or more 33 83 83 Required space The required ceiling depth varies according to configration of specific system 195 Drain connection location for rear piping 800 595 (Air suction parelcenter) 440 315 25 228 Drain connection location for upper piping 60 50 465 or more Required installation space A B C D 135 120 CEILING SUSPENDED CASSETTE TYPE 6 60 5 4 Approx.345 Approx.390 Approx.475 Mounting location 98 80 hole Piping and Wiring intake 1 2 3 4 5 6 7 8 9 Front panel Front grille Air outlet Gas pipe Liquid pipe Drain hose Grounding terminal Right side pipe connection hole Left side pipe connection hole 62 DIME N S ION S (Unit: mm) WALL MOUNTED TYPE DUCT CONNECTION LOW STATIC PRESSURE TYPE Piping direction A 580 A A A A A 4 5 45 142 A 53 A 2 110 170 228 360 A 684 664 D Direction for air filter draw out 50 123 Service space 126 164 134 107 120 120 C (Suspension bolt pinch) 260 210 (Required space) 120 50 or more 180 100 10 10 50 40 40 50 35 50 30 40 40 Approx. 450 Approx. 580 Approx. 600 6 15 40 50 70 120 1235 120 Ceiling surface 15 60 40 6 6 2 8-5x20 Oval Hole (For wood screw) 5-6x20 Oval Hole (For wood screw) 8 5 13- 5 Hole (For wood screw) 2- 12 Hole (For bolt) 4 60 E K (All around) 80 Hole Piping and wiring intake 6 29 150 219 236 250 or more Service space for air filter 7 127 1 Mounting location Detail A (Mounting hole for installation plate) 1 2 3 4 5 6 7 8 9 Notes: 1 Location of general rated name plate Right side plate outside surface 2 In case of using wireless remote controller, this position will be a signal receiver. Refer to the drawing of wireless remote controller in detail. Front grille Air filter Discharge outlet Gas piping connection Gas piping connection Drain piping connection Earth terminal (M4) (inside cover) Slit hole for right side piping connection Slit hole for left side piping connection FLOOR STANDING TYPE 1 2 3 4 5 6 7 8 Liquid pipe connection Gas pipe connection Drain pipe connection Ground terminal Switch box Control wiring intake (for outdoor unit) Control wiring intake (for remote controller) Suspension bracket Note: 1Location of unit's Name Plate: Chamber cap F G H I J 16 10 151 L (All around) 52 16 10 Brand name plate Note 2. 3 55 8 200 74 317 7 360 9 10 or more 3 1 300 or more 260 1570 3 271 50 or more (Required space) 137 167 50 or more (Required space) 595 500 (Suspension bolt pinch) B [FAY100FAVE] A B C D E F G H I J FDBG25AVE/35AVE/50AVE 900 704 755 3XP150=450 500 3XP150=450 674 688 704 900 K L FDYB25KVE/35KAVE/50KAVE FDBG60AVE/71AVE 900 704 755 3XP150=450 1300 1104 1155 6XP150=900 500 700 3XP150=450 674 688 704 900 6XP150=900 1074 1088 1104 1300 10-M4 12-M4 FDYB60KAVE/71KAVE 1300 1104 1155 6XP150=900 700 6XP150=900 1074 1088 1104 1300 16-M4 18-M4 10-M4 12-M4 Holes Holes Holes Holes 16-M4 18-M4 Holes Holes Holes Holes DUCT CONNECTION MIDDLE STATIC PRESSURE TYPE A 3 18 330 A DETAIL OF CONTROL PANEL 1850 OR 50 1 RE 6 50 95 75 F G H REQUIRED SPACE 3 THROUGH HOLE FOR SIDE PIPING 4 THROUGH HOLE FOR SIDE PIPING 5 THROUGH HOLE FOR SIDE WIRING 6 THROUGH HOLE FOR REAR PIPING/WIRING 7 THROUGH HOLE FOR BOTTOM PIPING/WIRING 8 LIQUID PIPE CONNECTION 5 4 R 0O R MO 1 SUCTION GRILL 2 AIR FILTER D 100 95 63 6 6 541 616 825 34 598 MO 0 15 3 E 2 184 184 9 GAS PIPE CONNECTION 10 DRAIN PIPE CONNECTION NOTES: 1STICKING LOCATION FOR MANUFACTURE'S LABEL : ON THE SURFACE OF COVER OF SWITCH BOX INSIDE THE SUCTION GRILL. 151 8 16 4 51 1350 1153 1137 1121 7XP150=1050 5 305 H 29 6 1 7 20-M4 Holes (All around) OR E APPROX. 36 200 223 253 D E F G (All around) MO RE FULL OPEN POSITION OF SUCTION B GRILL C [FDMG71AV1] 305 206 175 123 740 OR MORE TAKE OUT DIMENSION OF AIR-FILTER 2 9 126 (Suspension bolt pinch) 2-7X15 OBLONG HOLE (FOR WOOD SCREW) 50 Service space 1 2 3 4 5 6 7 8 [FDMG100AV1/125AV1/140AV1/180AV1] Liquid pipe connection Gas pipe connection Drain pipe connection Ground terminal Switch box Control wiring intake (for remote controller) Control wiring intake (for outdoor unit) Suspension bracket I 151 8 16 J K L 51 M 305 314 677 FIXTURE (ACCESSARY) 10 C IN CASE OF FIXING IT AT THE REAR NORMAL INSTALLATION TAKE OUT DIRECTION OF AIR-FILTER 8 8 150 263 280 IN CASE VIBRATION RESISTANCE IS REQUIRED, FIX IT AT BOTH THE BOTTOM AND THE REAR. 7 4- 14HOLE (FOR BOLT) 68 3 300 or more 74 16 10 126 THIS MODEL TO BE FIXED WITH FIXTURE AS SHOWN BELOW. IN CASE OF FIXING IT AT THE BOTTOM 150 263 280 215 130 J 130 K FVY100LAVE/125LAVE 350 44 49 130 190 260 266 322 79 202 229 VIEW Note: 1Location of unit's Name Plate: Chamber cap N A G H 1350 1153 1203 1134 1114 7XP150=1050 18-M4 727 FDMG100AV1/125AV1/140AV1 1550 1353 1403 1334 1314 7XP150=1050 FDMG180AV1 1900 1703 1753 1684 1664 9XP150=1350 18-M4 827 827 FDMG71AV1 B C D E F Holes Holes 22-M4 Holes 74 16 10 270 45 50 50 110 180 186 242 57 144 149 600 151 260 381 B L 146 K 116 J 600 H (Suspension bolt pinch) G 55 F 152 212 274 E 427 D 50 C L FVY71LAVE B 680 A (All around) I J K L M FDMG100AV1/125AV1/140AV1 1550 1353 1337 1321 7XP150=1050 FDMG180AV1 1900 1703 1687 1671 9XP150=1350 N 20-M4 Holes 24-M4 Holes 64 DIME N S ION S (Unit: mm) DUCT CONNECTION MIDDLE STATIC PRESSURE TYPE DUCT CONNECTION HIGH STATIC PRESSURE TYPE 236 220 (OPENING) 680 9 [FD08KY1] [FD10KY1] 1200 or more P 72 287 3 7 FDYM03FA FDYM04FA-06FA N P 5xP150=750 16- 7 HOLE 8xP150=1200 22- 7 HOLE 5 J 850 1250 K 14- 7 HOLE 20- 7 HOLE L 1079 1479 M 1064 1464 DUCT CONNECTION HIGH STATIC PRESSURE TYPE Q T 46 V U 3 FD06KY1 FD08KY1 FD10KY1 A B 756 732 732 35 39 39 C D E F G 967 5XP.180=900 1130 1180 1230 876 4XP.180=720 1130 1180 1230 1076 5XP.180=900 1330 1380 1430 2-M4 Burring holes (Both sides) 1 H I J K L M N O P Q R S T U V 6-M4 Burring holes 5-M4 Burring holes 6-M4 Burring holes 9 10 10 50 58 58 58 67 67 266 294 294 150 160 160 261 311 311 75 100 100 148 155 155 58 67 67 418 468 468 450 500 500 9 10 10 90 79 79 85 47 47 DUCT CONNECTION HIGH STATIC PRESSURE TYPE B 35 3 756 3 3 3 9 Service Space C 9 9 B 10 850 A 300 or more 850 9 35 6 D E E D F G Air inlet 9 FD03KY1 FD04KY1 FD05KY1 735 4XP150=600 C 650 900 900 D E 700 750 950 1000 950 1000 58 9 800 or more 196 [FDY08KAY1] Service Space 325 [FDY10KAY1] 1200 or more 2-M4 Burring holes (Both sides) 4 9 2 4 50 50 58 75 85 O L K J K L M N 450 418 J 90 266 150 9 46 B 2XP120=240 3XP150=450 58 9 [FDY06KAY1] 261 9 3 A 302 552 10 4 58 266 150 2-M4 Burring holes (Both sides) 3 3 63 148 5 50 2 9 3 1200 or more 9 2-M4 Burring holes (Both sides) Arrow View 1 1 2 3 4 5 6 Liquid pipe connection Gas pipe connection Drain pipe connection Earth terminal Power supply Suspension bracket I 50 [FD05KY1] 50 3 63 [FD04KY1] 50 800 or more [FD03KY1] Service Space S (Both sides) S (Both sides) 9 9 D E B A C B A Air outlet H 118 FDYM03FA FDYM04FA-06FA H 834 1234 T Liquid pipe connection Gas pipe connection Drain pipe connection Earth terminal Power supply Suspension bracket 130 130 295 130 SUCTION SIDE (NOTE.1) 2-M4 Burring holes (Both sides) R S E F G 38- 4.7 HOLE 30- 4.7 HOLE 4xP150=600 50- 4.7 HOLE 44- 4.7 HOLE 7xP150=1050 L M FDYM03FA FDYM04FA-06FA 4 (SERVICE SPACE) 1 2 3 4 5 6 4 50 5 2 J 9 [FD06KY1] 3 Service Space N A B C D 1100 11xP65=715 15xP65=975 1140 1500 18xP65=1170 21xP65=1365 1540 G D C E F I L M FDYM03FA FDYM04FA-06FA INSPECTION HOLE 450 OR MORE 1 31 I K 136 H (Both sides) 63 E (ALL ROUND) 145 95 DISCHARGE SIDE 3 H (Both sides) NOTES: 1 MOUNT THE AIR FILTER AT THE SUCTION SIDE. SELECT ITS COLORIMETHOD (GRAVITY METHOD) 50% OR MORE. 58 750 OR MORE (SERVICE SPACE) 25 680 OR MORE 2 B O P (ALL ROUND) K (ALL ROUND) 125 6 850 A C D 1 LIQUID PIPE CONNECTION [ 9.5(FLARE CONNECTION)] 2 GAS PIPE CONNECTION [03F: 15.9(FLARE CONNECTION)] [04~06F: 19.1(FLARE CONNECTION)] 3 DRAIN PIPE CONNECTION[VP25] 4 EARTH TERMINAL (INSIDE SWITCH BOX) 5 POWER SUPPLY 6 SUSPENSION BRACKET [FOR M10 or M8 BOLT] 7 MANUFACTURER'S LABEL N M L D (SUSPENSION POSITION) C B 100 6 B A H G 115 100 J F (ALL ROUND) 800 or more 600 (SUSPENSION POSITION) 50 210 194 (OPENING) I 46 P Q 2-M4 Burring holes (Both sides) A FDY06KAY1 756 FDY08KAY1 732 B 35 39 C 9 10 D 967 876 E F G H 5XP180=900 1130 1180 1230 4XP180=720 1130 1180 1230 I 9 10 J 58 67 K 150 160 L 266 294 M 418 468 N 450 500 O 261 311 P 90 79 Q 85 47 FDY10KAY1 732 39 10 1076 5XP180=900 1330 1380 1430 10 67 160 294 468 500 311 79 47 8 1 6 5 7 1 2 3 4 5 6 7 8 9 10 11 Liquid pipe connection Gas pipe connection Drain pipe connection Earth terminal Hole for power supply Hole for motor wiring Hole for wiring from outdoor unit Hole for remote controller wiring Control box Auxiliary pipe Suspension bracket Note: 1Location of unit's Name Plate: Lid of control box. 65 66 DIME N S ION S (Unit: mm) DUCT CONNECTION HIGH STATIC PRESSURE TYPE OUTDOOR UNIT // R25JV1, R35JV1 50 or more 12 33 7 Service Space 10 NAME PLATE 19 265 7 4 3 6 5 10 100 50 Service Space 12 190 *1 7- o/ 3.1 holes (Upward and downward) Air inlet 306 290 95 48 237 60 170 213 *1 10- o/ 3.1 holes (Upward and downward) Air outlet B 520 DRAIN OUTLETS 10 1045 700 HOLES FOR ANCHOR BOLTS (M8 OR M10) 5 B C D E F G 100 or more 50 Supprting plate (Commercially available) 800 or more 100 or more 50 OUTDOOR UNIT // R35GV1, RY35FV1A, R50GV1 DUCT CONNECTION HIGH STATIC PRESSURE TYPE (Commercially available) 150 Evaporator air outlet connection Evaporator air inlet connection Liquid pipe connection (No.1) Gas pipe connection (No.1) Liquid pipe connection (No.2) Gas pipe connection (No.2) Drain pipe connection Earth terminal Power supply intake The holes for anchor bolts 300 544 625 3XP150=450 45 61 763 805 Notes: 1Prepared holes for M4 tapping screw. 38 349 22.5 2XP150=300 257 1 2 3 4 5 6 7 8 9 10 1 10 72 100 530 +4 0 +4 A B C D E F G 500 9XP150=1350 1042 1620 1710 1750 1770 800 or more 11XP150=1650 1762 1980 2070 2110 2220 H 24 54 10 27 SERVICE PORT MINIMUM SPACE FOR AIR PASSAGE 50 50 100 763 805 Liquid pipe connection (No.1) Gas pipe connection (No.1) Liquid pipe connection (No.2) Gas pipe connection (No.2) Drain pipe connection Earth terminal Hole for power supply Hole for motor wiring Hole for wiring from outdoor unit (No.1) Hole for wiring from outdoor unit (No.2) Hole for remote controller wiring Control box The holes for anchor bolts 58 150 8 38 7 Arrow view (detail) 1 2 3 4 5 6 7 8 9 10 11 12 13 105 300 6 LIQUID STOP VALVE 34 150 *1 4- o/ 3.1 holes (Both sides) 12 GAS STOP VALVE 35 100 600 850 3XP150=450 2XP150=300 22.5 257 349 FDY15KAY1 FDY20KAY1 11 10 POWER INTAKE NAME PLATE 544 625 100 10 Arrow view 3 500 or more 35 *1 3- o/ 3.1 holes (Both sides) 4 5 [FDY20KAY1] 9 1 540 2 Service Space 14 [FDY15KAY1] 0 EARTH TERMINAL (M4) A 485 12580 80 80 270 H 172 20 45 61 12580 80 80 +4 15 0 71.5 55 193 55 477.5 6 72.5 200 168 750 6 21 LIQUID STOP VALVE (o/ 6.4CuT) WALL HEIGHT ON AIR OUTLET SIDE =LESS THAN 1200 *1 4- o/ 3.1 holes (Both sides) 2 Supprting plate 12.7 178 GAS STOP VALVE (o/ A CuT) MINIMUM SPACE FOR AIR PASSAGE 35 *1 3- o/ 3.1 holes (Both sides) 50 or more R35JV1 150 600 850 100 100 35 H 24 54 118 SERVICE PORT 500 or more 50 or more TERMINAL STRIP WITH EARTH TERMINAL 78 Service Space [FD20KY1] A B C D E F G FD15KY1 10- o/ 3.1 holes 9XP.150=1350 1042 1620 1710 1750 1770 FD20KY1 12- o/ 3.1 holes 11XP.150=1650 1762 1980 2070 2110 2220 WIRING INLET 50 [FD15KY1] 8 74 800 or more 55 55 125 80 80 80 70 10 10 125 80 80 80 695 9.5 B C D E F G *1 7- o/ 3.1 holes (Upward and downward) R25JV1 50 9 115 560 9 470 H 172 1045 8 A *1 A (Upward and downward) 477.5 72.5 8 6XP.150=900 288 100 or more 800 or more Supprting plate (Commercially available) 4 –HOLES FOR ANCHOR BOLTS (M8 OR M10) 420 304 DRAIN OUTLET (I. D o/ 15.9 HOSE FOR CONNECTION) 100 or more 50 or more 20 Supprting plate (Commercially available) 50 Notes: 1Prepared holes for M4 tapping screw. 67 68 (Unit: mm) OUTDOOR UNIT // R71FUY1, RG71AV1/AY1 OUTDOOR UNIT // RY50GAV1A, R60GV1 269 2-DRAIN OUTLET Hole for anchor bolt 4-M12 98 37 370 84 44 396 330 350 31 HOLES FOR ANCHOR BOLTS (M8 OR M10) 30 DIME N S ION S 130 146 800 OUTDOOR AIR THERMOSTAT 300 15 584 30 540 150 880 30 4 EARTH TERMINAL (M4) 3 2 POWER INTAKE 816 6 5 5 60 LIQUID PIPE 100 GAS PIPE 84 95 14 49 90 95 195 221 75 49 24 GAS STOP VALVE 84 95 70 60 SERVICE PORT UNIT NAME PLATE 7 6 1 UNIT NAME PLATE LIQUID STOP VALVE 645 685 7 137 14 Name plate 67 115 102 11 61 11 40 A Knock hole for lower piping 1 Gas pipe connection 2 Liquid pipe connection 100 50 150 H 275 MINIMUM SPACE FOR AIR PASSAGE A 50 3 Service port (in the unit) 4 Grounding terminal 50 H H H 1000 1000 A 300 600 391 5 Refrigerant piping intake 6 Power supply wiring intake 8 7 Control wiring intake 8 Drain outlet OUTDOOR UNIT // R(Y)71LUV1/Y1 OUTDOOR UNIT // RY60GAV1A HOLES FOR ANCHOR BOLTS (M8 OR M10) 177 120 500 40 TERMINAL COVER 190 OUTDOOR AIR THERMOSTAT 3-DRAIN OUTLET 881 55 15 140 96 140 620 900 30 3 4 2 1 7 9 6 5 350 EARTH TERMINAL (M4) 686 770 POWER INTAKE 7 6 5 SERVICE PORT 71 8 100 70 102 A 352 19 80 52 145 13 67 16 58 110 117 120 30 223 53 95 143 54 95 19 16 40 MINIMUM SPACE FOR AIR PASSAGE 100 89 142 UNIT NAME PLATE 100 89 28 145 60 GAS STOP VALVE 329 55 55 LIQUID STOP VALVE 54 95 84 55 40 30 48 55 320 350 (345~355) 410 128 40 370 90 30 Hole for anchor bolt 4-M12 5 45 376 191 100 69 100 A 1000 350 H 1000 600 H A H 1 2 3 4 5 6 7 8 9 Gas pipe connection Liquid pipe connection Service port Grounding terminal Refrigerant piping outlet Power supply wiring outlet Control wiring outlet Drain outlet Supplied piping Note: In some circumstances, with certain machine types, it may not be possible to attach the supplied piping. 70 DIME N S ION S (Unit: mm) OUTDOOR UNIT // R100FUV1/Y1, 125FUY1 30 OUTDOOR UNIT // R(Y)125LUY1, 140LUY1 Hole for anchor bolt 4-M12 B C D R(Y)125LUY1 1170 A 54 113 579 R(Y)140LUY1 1345 55 — — 30 Hole for anchor bolt 4-M12 584 30 48 61 320 350 (345~355) 370 150 41 880 140 96 140 620 900 30 4 30 146 30 35 396 84 38 3 3 2 4 1 7 1 6 2 7 5 6 14 89 24 14 67 115 C 89 19 D 102 8 71 223 80 52 145 13 5 Refrigerant piping intake 6 Power supply wiring intake OUTDOOR UNIT // R(Y)100LUV1/Y1 3 Service port (in the unit) 4 Grounding terminal M5 (in switch box) 5 Refrigerant piping intake 5 45 7 Control wiring intake 8 Drain outlet 8 1 Gas pipe connection 2 Liquid pipe connection 58 3 Service port(in the unit) 4 Grounding terminal 376 67 16 16 1 Gas pipe connection 2 Liquid pipe connection Knock hole for lower piping 391 19 142 70 102 117 11 61 11 137 275 40 90 148 95 54 55 410 435 95 54 60 60 95 49 84 95 49 84 24 Name plate 5 B 5 5 568 538 6 60 7 6 A 7 84 1215 5 6 Power supply wiring intake 7 Control wiring intake 191 8 Drain pipe connection OUTDOOR UNIT // RU06KY1 620 880 140 320 30 3 900 30 36 30 41 620 320 345 80 34 96 140 130 30 130 30 Hole for anchor bolt 4-M12 320 61 48 350 (345~355) 30 Hole for anchor bolt 4-M12 4 4 2 3 1 2 7 7 5 54 5 71 376 191 55 406 84 95 95 51 28 53 15 67 15 36 145 58 100 200 Gas pipe connection Liquid pipe connection Service port Grounding terminal Refrigerant piping outlet Power supply wiring outlet Control wiring outlet Drain outlet Supplied piping 285 1 2 3 4 5 6 7 8 9 12 12 54 58 117 70 102 45 Note: In some circumstances, with certain machine types, it may not be possible to attach the supplied piping. 14 137 67 16 5 89 53 name plate 88 13 28 52 145 16 71 376 60 223 80 70.5 8 5 54 95 84 55 6 19 19 142 6 7 435 410 95 157.5 60 89 24 89 5 6 120 6 5 7 7 55 6 1345 7 5 1 148 1170 6 223 9 Knock hole for lower pipng 41 377 8 644 1 Gas pipe connection 2 Liquid pipe connection 3 Service port (in the unit) 4 Grounding terminal M5 (in switch box) 5 Refrigerant piping intake 6 Power supply wiring intake 7 Control wiring intake 8 Drain pipe connection 72 DIME N S ION S (Unit: mm) OUTDOOR UNIT // RU08KY1/10KY1 A 30 Hole for anchor bolt 4-M12 1000 RU08KY1 1220 4- 15 Holls For anchor bolts 370 RU10KY1 1440 584 30 146 700 35 395 84 38 ( Pitch of anchor bolts ) 150 880 30 726 ( Pitch of anchor bolts ) OUTDOOR UNIT // RG140AY1/180AY1 1290 4 3 2 1 7 1345 6 5 3 A 7 6 4 76 61 11 1440 ( for side-roted pipes ) 95 A 4- 15mm-dia.holes ( Foundation bolt holes ) 220 1000 B R(Y)200KUY1 228 1220 R(Y)250KUY1 224 1440 ( Pitch of anchor bolts ) Notes: 1. The dimensions marked by an asterisk( ) are those with the installation of the provided pipes. 2.Refer to the installation instructions when the pipes are routed through the bottom of the unit. 4- 15 Holls For anchor bolts 1290 95 726 229 1 Liquid pipe conn. 2 Gas pipe conn. 3 Earth terminal (M5) (in the el.compo. box assy) 4 Wiring intake ( side ) 5 Refrigerant piping conn. ( side ) 6 Refrigerant piping conn. ( Bottom ) ( Pitch of anchor bolts ) 71 97 700 RU10KUY1 1000 ( Pitch of foundation bolt holes ) ( Pitch of foundation bolt holes ) C 1220 80 750 OUTDOOR UNIT // R(Y)200KUY1/250KUY1 700 B 225 54 8 Drain outlet 726 A 76 6 32 name plate 110 6 Power supply wiring intake 7 Control wiring intake OUTDOOR UNIT // RU08KUY1/10KUY1 RU08KUY1 1280 3 Service port(in the unit) 4 Grounding terminal M5(in switch box) 5 Refrigerant piping intake 8 80 20 5 1 Gas pipe connection 2 Liquid pipe connection 5 391 202 32 690 275 40 137 165 90 165 14 90 14 67 115 2 156 144 60 49 14 102 11 70 1 52 177 90 84 95 49 84 24 name plate 4 5 95 60 538 568 70 5 Notes The dimension ( with marked ) are attached accessory pipe. 1290 ( In case of side conn. ) 3 C 3 70 1280 6 750 name plate (Knock-out hole) 5 110 65 55 13 73 62 97 165 80 90 80 220 155 265 A (for frontroted pipes) 70 150 80 2 750 1280 690 1 Liquid pipe connection port. 2 Gas pipe connection port. 3 Earth terminal (M5) (inside of control box) 4 Power cord routing hole ( side ) 5 Pipe routing hole ( side ) 6 Pipe routing hole ( Bottom ) 265 1 34 54 690 1 2 110 A 135 170 (Knock-out hole) 70 4 60 123 150 230 29 32 165 150 90 B 52 177 220 156 70 5 76 4 4 4 B 70 13 97 6 name plate ( In case of front conn. ) 1 Liquid pipe conn. 2 Gas pipe conn. 3 Earth terminal (M5) (in the el.compo. box assy) 4 Wiring intake ( side ) 5 Refrigerant piping conn. ( side ) 6 Refrigerant piping conn. ( Bottom ) 74 DIME N S ION S (Unit: mm) [Space required for outdoor unit installation] (Unit: mm) REMOTE CONTROLLER Dimensions inside brackets [ ] indicate case where air direction adjustment guide is adjusted downward. The values represent the case for the R(Y)71 type through R(Y)140 type. The dimensions in ( ) are for the R(Y)100 and R(Y)140 type (The unit values is mm. ) For R(Y)71LU-140LU RECEIVER When there is an obstruction in the overhead space When the overhead space is open 157 1. For single unit installation • RECEIVER DETAIL When there is an obs truc tion on the inlet s ide REFRIGERANT PIPING SIDE REMOTE CONTROLLER HOLDER INSTALLATION PROCEDURE <INSTALLATION TO WALL SURFACE> When there are obs truc tions on both s ides • •RECEIVER INSTALLATION PROCEDURE RECEIVER FAY100FA DECORATION PANEL 1. For single unit installation s r les o An obs truc tion in the overhead s pac e re mo or ) 50 (100 100 When there are obs truc tions on the inlet s ide and ss or le both lateral s ides 500 • RECEIVER DETAIL LIQUID CRYSTAL REMOTE CONTROLLER (WIRELESS) 100 or m ore 100 RECEIVER DETAIL 2-5x9 Slot 18 re 150 or 150 mo re When there are obs truc tions on the inlet s ide and both lateral s ides rm ore 100 ore rm 0o ) 20 (300 or m ore 49 1. For single unit installation s ore An obs truc tion in the overhead s pac e 500 2. For series installation (more than two units) rm ore or m 50 (100) H ore rm 0o or m ore or m 200 (300) 100 ss or le 500 An obs truc tion in the overhead s pac e ore 200 • RECEIVER DETAIL (Ceiling opening) or m 2. For series installation (more than two units) or le L An obs truc tion in the overhead s pac e 100 0o Switch box ore or m 500 ore ss 500 H ore r les o 500 0o 70 rm 0o 100 When there is an obstruction in the overhead space mo 1. For single unit installation L 2. For series installation (more than two units) 200 0.5 35 or L 2. For series installation (more than two units) When there are obs truc tions on both s ides RECEIVER (Ceiling opening) 120 72 83.5 106 The Front or 500 re mo ore or m 1000 or more • • RECEIVER DETAIL CEILING SUSPENDED TYPE •RECEIVER INSTALLATION PROCEDURE 150 1 ore REMOTE CONTROLLER HOLDER When the overhead space is open 2. For series installation (more than two units) An obs truc tion in the overhead s pac e ore rm o 00 or m When the obstruction on the outlet side is higher than the unit itself (There is no limit to the height of the obstruction on the outlet side.) H 17.5 500 Pattern 1 When the overhead space is open 1. For single unit installation When there is an obs truc tion only on the inlet s ide When there are obstructions on both the inlet and outlet sides H DRAIN PIPING SIDE 62 When there is an obstruction on the outlet side When there is an obstruction on the inlet side L TRANSMITTING PART WALL MOUNTED TYPE •RECEIVER INSTALLATION PROCEDURE FAY71L RECEIVER 1000 or more CEILING MOUNTED CASSETTE TYPE •RECEIVER INSTALLATION PROCEDURE 1000 or more REMOTE CONTROLLER DIMENSIONS 1000 or more • 1000 or more Wireless type or ore rm 0o ) 20 (300 mo re (field Supplied parts) ore rm 0o 100 More than 90 (Srevice space) Service space for ceiling installation Note : Do not install more than 3 receivers in the vicinity of one another. With 4 or more units, there is always the possibility of malfunction For R(Y)200KU /250KU In case of single installation In case of parallel installation In case of set installation Wired type •REMOTE CONTROLLER DIMENSIONS Pattern 1 •REMOTE CONTROLLER INSTALLATION PROCEDURE A EXPOSED BODY, EXPOSED CORD B EXPOSED BODY, EMBEDDED CORD 17 CONDUIT 84 120 10 or more 117 38 Pattern 1 300 or more 42 STAPLE Pattern 1 300 or more 10 or more FRONT SIDE 500 or more 10 or more 20 or more FRONT SIDE 500 or more 300 or more 10 or more 20 or more 10 or more 20 or more FRONT SIDE FRONT SIDE 10 or more 10 or more 600 or more 0~5 500 or more 10 or more 20 or more 900 or more 17 18 CORD OUTLET HOLE 23 28 Pattern 2 17 CONTROL BOX C EXPOSED BODY, EMBEDDED CODE 46 100 or more NOTE) 1. REMOTE CONTROLLER CORD AND STAPLE ARE NOT ATTACHED. THEY ARE FIELD SUPPLIED PARTS. 50 or more THROUGH HOLE (fl12~fl16) ( DISTANCE BETWEEN REMOTE CONTROLLER AND CONTROL BOX ) SIZE 0.75~1.25 mm2 TOTAL LENGTH 500 m 100 or more FRONT SIDE 500 or more The height of obstacle is free Pattern 3 10 or more Pattern 2 300 or more 200 or more 124 FRONT SIDE 500 or more The height of obstacle is free 50 or more 400 or more FRONT SIDE 100 or more FRONT SIDE 500 or more 400 or more KRC47-3A 136 18 FRONT SIDE 10 or more FRONT SIDE 500 or more 20 or more 100 or more 100 or more Pattern 3 50 or more 100 or more FRONT SIDE 500 or more 50 or more 50 or more 50 or more 100 or more 50 or more 100 or more 600 or more 50 or more 50 or more FRONT SIDE 500 or more 136 32 124 32 14 61 If the number of units is more than that shown in this manual. take short circuit into account. 35.50 36 92 85 4 For the service space for front side. take the service space required for field piping into account. FRONT SIDE SUCTION SIDE h1 For the service space. if the obstacle of height exceeds the above mentioned dimensions. half of the exceeded dimensions shall be added to the standard service space. When installing a unit. choose the most suitable one from this manual depending on actual conditions such as walking passage and ventilation. 500 mm 3 h2 Front side 1500 mm Suction side 500 mm Side No (imitation) 81 81 58 19 Notes: 1 Obstacies height of (Pattern 1) and (Pattern 2) shall be as follows: 2 75 50 or more 300 or more 110 FRONT SIDE 500 or more 50 or more * Countries requiring EMC: Shield wire (insulated thickness: 1 mm or more) KRC47-1A 25 FRONT SIDE 500 or more 50 or more (INSULATED THICKNESS: 1 mm OR MORE) •REMOTE CONTROLLER KRC47-2A/ KRC47-4A 20 or more VINYL CORD WITH SHEATH OR CABLE TYPE 17 10 or more 100 or more 10 or more 10 or more SPECIFICATIONS OF CORD •DIGITAL REMOTE CONTROLLER Pattern 2 1500 mm 120 85 76 MEMO 77 78