Download Installation Instructions
Transcript
I n s t a l l a t i o n I n s t ru c t i o n s SELECTRONIC™ PROXIMITY TOILET CONCEALED FLUSH VALVE 1.28 & 1.6 GPF MODEL NUMBERS 6065.22X 6065.26X 6067.22X 6067.26X 6068.22X 6068.26X Concealed Flushometer for 1-1/2" Top or Back Spud Bowls CLOG RESISTANT • Self-cleaning piston valve prevents clogging and reduces maintenance. ONE SENSOR FITS ALL Certified to comply with ASME A112.19.2M © 2010 AS America, Inc. • Only 1 sensor for entire Selectronic™ line of faucets, urinals, and flush valves. • Range can be adjusted manually or with optional remote control. • Sensor Features Low Battery Indicator. M968550 REV. 1.5 NOTE TO INSTALLER: Please give this manual to the customer after installation. To learn more about American Standard Faucets visit our website at: www.americanstandard-us.com or U.S. customer's e-mail us at: [email protected] For Parts, Service, Warranty or other Assistance, please call 1-800-442-1902 (In Canada: 1-800-387-0369) (In Toronto Toronto Area Area only: only: 1-905-3061093) 1-905-3061093) (In Thank you for selecting American-Standard...the benchmark of fine quality for over 100 years.To ensure that your installation proceeds smoothly--please read these instructions carefully before you begin. UNPACKING All American Standard Products Are Water Tested At Our Factory. Some Residual Water May Remain In The Valve During Shipping. 1. Remove the Flush Valve items from the carton. The illustration below shows all items after they have been removed from the carton. Some items may be packaged partially assembled to other items. 1. Flush Valve Assembly 2. Electrical Box 3. Cover Plate with Sensor 4. Supply Stop 5. Sweat Solder Adapter 6. Manual Override Hoses 7c. Vacuum Breaker Flush Connection (Top Spud) 8a. AC Power Supply [Model# 6067] 8b. DC Power Supply 8c. 10’ Extension Wire for Multi-AC 9. Installation Instructions 7a. Vacuum Breaker Flush Connection (Wall-Mount Back Spud) 7b. Vacuum Breaker Flush Connection (Floor-Mount Back Spud) CARE INSTRUCTIONS FOR CHROME PLATED ITEMS: DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH. DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A CLOTH WITH A COARSE SURFACE. TOP I n s t a l l a t i o n I n s t ru c t i o n s DO NOT REMOVE PROTECTIVE FILM FROM SENSOR EYE UNTIL INSTALLATION IS COMPLETE. 2 3 6 4 1 9 5 SELECTRONIC™ PROXIMITY TOILET CONCEALED FLUSH VALVE 1.28 & 1.6 GPF MODEL NUMBERS 6065.22X 6065.26X 6067.22X 6067.26X 6068.22X 6068.26X Concealed Flushometer for 1-1/2" Top or Back Spud Bowls CLOG RESISTANT • Self-cleaning piston valve prevents clogging and reduces maintenance. ONE SENSOR FITS ALL Certified to comply with ASME A112.19.2M © 2009 AS America, Inc. • Only 1 sensor for entire Selectronic™ line of faucets, urinals, and flush valves. • Range can be adjusted manually or with optional remote control. • Sensor Features Low Battery Indicator. M968550 REV. 1.5 NOTE TO INSTALLER: Please give this manual to the customer after installation. To learn more about American Standard Faucets visit our website at: www.americanstandard-us.com or U.S. customer's e-mail us at: [email protected] For Parts, Service, Warranty or other Assistance, please call 1-800-442-1902 (In Canada: 1-800-387-0369) (In Toronto Toronto Area Area only: only: 1-905-3061093) 1-905-3061093) (In 7b 7a 7c 8b 8a 8c M968550 REV. 1.5 1 Fig. 1 Roughing-in Dimensions GENERAL DESCRIPTION: 25mm (1) MAX. FINISHED WALL 160mm (6-1/4) SELECTRONIC™ PROXIMITY TOILET FLUSH VALVE Concealed Flushometer for 1-1/2" Spud Fixtures MAXIMUM DETECTION ZONE 400mm-800mm (15-3/4 TO 31-1/2) TOP SPUD TOILET 160mm (6-1/4) OVERRIDE BUTTON SENSOR 15˚ Exclusive, self cleaning piston-type flush valve with proximity operation and manual override. Operates on DC (b a tte r y ) o r AC p owe r. Re c o m m e nd e d operating pressure 25psi (flowing) to 80 psi (static). Can install left or right-handed. Detection Zone can also be adjusted manually, or with optional remote control. 127X127mm (5X5 CUTOUT FOR BOX) EXPOSED BACK SPUD TOILET 406mm (16) SUPPLY DN 25mm (1) I.P.S. -C-L- * -C-L152mm (6) MIN. 51mm (2) + WALL THICKNESS 115mm-134mm (4-1/2 TO 5-1/4) 403 TO 441mm (15-7/8) MIN. TO (17-3/8) MAX. CONCEALED BACK SPUD TOILET 289 TO 403mm (11-3/8 MIN. TO 15-7/8 MAX.) 432mm (17 MAX.) WALL THICKNESS 73 TO 111mm (2-7/8 TO 4-3/8) TOP OF FIXTURE TOP OF FIXTURE 73 TO 137mm (2-7/8)MIN. TO (5-3/8) MAX. 292mm (11-1/2) MAX. 19mm (3/4.) 51mm (2) TOP SPUD TOILET 127mm (5) MAX. 483mm (19) MAX. *Note: The Critical Line (-C-L-) on Vacuum Breaker must typically be 6 " (152mm) min. above fixture. Consult Codes for details. 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. *FOR LOCATION OF INLET SUPPLY ON BACK INLET FIXTURES,REFER TO FIXTURE BEING INSTALLED FOR CORRECT HEIGHT FROM FINISHED FLOOR 51mm (2) 71mm (2-3/4) DIA. RECOMMENDED TOOLS; Fig. 2 19mm (3/4.) 51mm (2) Fig. 2 Teflon Tape Flat Blade Screwdriver Adjustable Wrench Tape Measure Hacksaw Tubing Cutter File For Sweat Connection; Solder and Torch 2.5mm Hex Wrench 1.5mm Hex Wrench 2 1 3 4 10' 6 5 7 9 8 10 PRIOR TO INSTALLATION Note: Prior to installing the Selectronic™Flush Valve the following items must be installed. 1. Water Closet • Flush all water lines prior to operation (See Step 4). Dirt and debris can cause flush valve to run continuously. • With the exception of Supply Stop Inlet, DO NOT use pipe sealant or plumbing grease on any valve component or coupling! 2. Drain line 3. Water supply line IMPORTANT: • All plumbing must be installed in accordance with applicable codes and regulations. • Water supply lines must be sized to provide an adequate volume of water for each fixture. • Protect the chrome or special finish on chrome plated items. DO NOT USE toothed tools on finished surfaces to install or service these valves. Also see “Care and Cleaning” section of this manual. • This product contains mechanical and/or electrical components that are subject to normal wear. These components should be checked on a regular basis and replaced as needed to maintain the valve’s performance. M968550 REV. 1.5 2 1 INSTALL ELECTRICAL BOX Fig.3 (TOP SPUD FIXTURE ILLUSTRATED) ASSEMBLY; Fig. 3 2 127mm (5) 1. Cut a 127x127mm (5"x 5") opening in finished wall for ELECTRICAL BOX (1) at the deminsion shown in Fig.3. 127mm (5) 2. Rotate the 4 MOUNTING TABS (2) flat against the electrical box. Holding the MOUNTING TABS (2) in position install the ELECTRICAL BOX (1) into the opening. Make sure the MOUNTING TABS (2) are behind the wall. TOP 3 Fig. 3a TOP 3. Tighten the the 4 MOUNTING SCREWS (3) until the ELECTRICAL BOX (1) is almost secure in the wall. Before tighting fully rest a level at the top edge of the ELECTRICAL BOX (1) and make sure the box is level, then tighten fully. Fig. 3a. 406mm (16 REF.) 1 127mm (5 MAX.) 4. *Cut a 2" hole for supply to fixture at deminsion shown. 2 INSTALL SWEAT SOLDER Fig. 4 ADAPTER; Fig. 4 CAUTION *FOR HOLE LOCATION OF SUPPLY ON BACK INLET FIXTURES, REFER TO FIXTURE BEING INSTALLED FOR CORRECT HEIGHT FROM FINISHED FLOOR TOP Turn water supplies off before beginning 1 Note: Control stop inlet is 1" IPS. For optional sweat connection, install Sweat Solder Adapter (1) (Supplied) for 1" copper pipe supply line. Fig. 4. FILE EDGES 115mm-134mm (4-1/2 TO 5-1/4) 1. Clean the end of the supply pipe. Push the threaded ADAPTER (1) on until it is seated against the internal stop. Sweat the ADAPTER (1) to the pipe. CONTROL STOP OUTLET 2. From behind the wall install the CONTROL STOP (2) to the water supply line with the outlet positioned as required. 2 CONTROL STOP DN 25mm (1" I.P.S.) CLEAN & SOLDER TO ADAPTER (1) 2 403 TO 441mm (15-7/8 MIN. TO 17-3/8 MAX.) 3. Support piping as required. 3 FLUSH OUT SUPPLY LINES; Fig. 5 Fig. 5 COUNTER-CLOCKWISE OPENS CONTROL STOP 1. Open SUPPLY STOP (1). CLOCKWISE CLOSES CONTROL STOP 1 3. Turn on water supply to flush line of any debris or sediment. 4. Close SUPPLY STOP (1) and turn off water supply line. 3 M968550 REV. 1.5 443 INSTALL VACUUM BREAKER AND FLUSH CONNECTIONS; Fig. 6 2 3 Fig. 6 1. Place the SPUD FLANGE (1) over the spud on the Fixture. Fig. 6. 4 1 1-1/2" TOP SPUD 2. Thread SPUD COUPLING NUT (2) onto Spud. Make sure SEAL WASHER (4) and FRICTION WASHER (3) are installed. Do not tighten fully. Fig. 6. 3. Remove the COUPLING NUTS (6, 6a) from the CHROME ELBOW (5). Make sure you have a TAPERED RUBBER WASHER (7), PLASTIC SUPPORT (8) and SQUARE SEAL WASHER (9). Fig. 6a. Fig. 6a 5 TAPERED SIDE 4. Install the SQUARE SEAL WASHER (9) onto the PLASTIC SUPPORT (8) if not already installed. Insert the PLASTIC SUPPORT (8) into the DOWN TUBE (10). Slide the COUPLING NUT (6) onto the DOWN TUBE (10). Connect the COUPLING NUT (6) to the CHROME ELBOW (5) and tighten fully. Insert the DOWN TUBE (10) with CHROME ELBOW (5) into the SPUD COUPLING NUT (2) and push it down. Do not tighten fully. Fig. 6a. Note: If center line of ELBOW (5) cannot be adjusted to line up with hole in wall, then cut the DOWN TUBE (10) as required. 8 9 FLANGE END UP 6 10 2 Fig. 6b 5. Measure and cut the HORIZONTAL TUBE (11) to length required. Important: Make sure that there is a minimum of 1-1/4" for engagement with elbow when making your measurement. Fig. 6b. 15 13 12 6. Remove the COUPLING NUT (14) from BRASS ELBOW (12) and slide it onto the HORIZONTAL TUBE (11). Install the SQUARE SEAL WASHER (13) onto the PLASTIC SUPPORT (15) if not already installed. Insert the PLASTIC SUPPORT (15) into the HORIZONTAL TUBE (11). Connect the COUPLING NUT (14) to the BRASS ELBOW (12) and tighten fully. Fig. 6b. TOP SPUD INSTALLATION 16 TAPERED SIDE FLANGE END BACK SPUD INSTALLATION 14 11 6a 11 7. From behind the wall install the ELBOW AND TUBE ASSEMBLY (12, 11) through the hole in the wall. Install WALL ESCUTCHEON (16) onto HORIZONTAL TUBE (11). Assemble the COUPLING NUT (6a) and TAPERED RUBBER WASHER (7) in the CHROME ELBOW (5) onto the HORIZONTAL TUBE (11). Push the HORIZONTAL TUBE (11) into the CHROME ELBOW (5). Tighten COUPLING NUT (6a) but not fully. Fig. 6b. 7 5 Fig. 6c TOP SPUD INSTALLATION BACK SPUD INSTALLATION 8. For back spud installations: Follow steps #1 and #2 to install the spud coupling kit. Push the HORIZONTAL TUBE (11) into the spud connection on the back of the fixture. Do not tighten fully. If spud coupling kit is not required install HORIZONTAL TUBE (11) into back spud on fixture and hand tighten. Fig. 6b. 9. All installations: If required cut scored VACUUM BREAKER PIPE (17) to fit, leave a minimum of 1-1/4" (32mm) of pipe to ensure engagement with compression coupling. Assemble the COUPLING NUT (18) and TAPERED RUBBER WASHER (19) in the BRASS ELBOW (12) onto the VACUUM BREAKER PIPE (17). Install VACUUM BREAKER PIPE (17) into BRASS ELBOW (12) and hand tighten COUPLING NUT (18). Fig. 6c. 7 6a 17 TAPERED SIDE UP 18 19 TAPERED SIDE UP 19 12 Note: If cutting VACUUM BREAKER PIPE (16) to size, note that Critical Line (C/L) on Vacuum Breaker must typically be 6" (152mm) above fixture. Consult Code for details. 4 M968550 REV. 1.5 5 INSTALL FLUSH VALVE; Fig. 8 Fig. 8 1. Insert the side ADJUSTABLE TAILPIECE (1) on the FLUSH VALVE (2) into the SUPPLY STOP (3). Lubricate the TAILPIECE O-RING (4) with water if necessary. Lightly tighten COUPLING NUT (5). Fig. 8. Important: Do not use lubricants (other than water) or any type of thread sealing paste or tape. 3 1 2 6 CONNECT FLUSH VALVE TO 5 4 Fig. 9 PIPING; Fig. 9 121mm,+13mm, -6mm (4-3/4)(+1/2, -1/4) 7 Align the FLUSH VALVE (2) (Fig. 9) directly above 1. the VACUUM BREAKER TUBE (7) and VACUUM COUPLING NUT (6). Make sure that GASKET (10) is installed. Note: There is a +13mm, -6mm (+1/2, -1/4) tolerance for the 121mm (4-3/4) dimension. Fig. 9. 2 8 2. Pull the VACUUM BREAKER TUBE (7) up to meet the threaded FLUSH VALVE CONNECTION (8) and hand tighten the COUPLING NUT (6). Align all components of the flush valve assembly. Fig. 9. 6 5 10 7 3. Lightly tighten the TAILPIECE COUPLING NUT (5) connection first, then the VACUUM BREAKER COUPLING NUT (6) and finally the SPUD COUPLING NUT (9). Once alligned correctly, use a wrench to tighten all couplings to make water tight connections. Fig. 9. 4. Secure piping behind wall as required. 9 5 M968550 REV. 1.5 7 CONNECT FRONT PANEL TO Fig. 10 ELECTRICAL BOX (AC POWER); Fig. 10 1 1. Remove the four COVER SCREWS (1) and COVER from (2) ELECTRICAL BOX (4). Fig. 10. 2 TOP 4 2. Pull the CIRCUIT BOARD (3) out from ELECTRICAL BOX (4). Fig. 10. 3. Knock out lower blank in ELECTRICAL BOX (4) with flat blade screwdriver. Install from the back of ELECTRICAL BOX (4) the POWER SUPPLY GROMMET (8). Fig. 10a. 3 4. Attach the SAFETY CHAIN (5) from the FRONT PANEL (6) to the MOUNTING POST (7) as shown. Feed the Red and Black wires through the back opening in the ELECTRICAL BOX (4). Fig. 10a. Fig. 10a TOP 4 8 5. From back of ELECTRICAL BOX (4) remove SPLIT PLUG (8a) from POWER SUPPLY GROMMET (8). Insert POWER CORD CONNECTOR (9) through POWER SUPPLY GROMMET (8). Insert POWER CORD (10) into SPLIT PLUG (8a). Push SPLIT PLUG (8a) into POWER SUPPLY GROMMET (8) to seal. Fig. 10b. 7 KNOCK OUT BLANK 6 5 6. Insert POWER SUPPLY CONNECTOR (9) into RECEPTOR (11) on CIRCUIT BOARD (3). Install CIRCUIT BOARD (3) into ELECTRICAL BOX (4). Fig. 10b. BLACK & RED WIRES 7. Install the SENSOR WIRE GROMMET (15) into the COVER (2) as shown. Remove the SPLIT PLUG (15a) from SENSOR WIRE GROMMET (15). Insert SENSOR WIRE CONNECTOR (12) through SENSOR WIRE GROMMET (15). Insert SENSOR WIRE (13) into SPLIT PLUG (15a). Push SPLIT PLUG (15a) into SENSOR WIRE GROMMET (15) to seal. Fig. 10c. Fig. 10b 9 8a 10 8. Insert SENSOR WIRE CONNECTOR (12) into CIRCUIT BOARD RECEPTOR (14) slot. Fig. 10c. 8 3 4 TOP 7 11 8 9 9. Replace COVER (2). Tighten COVER SCREWS (1) firmly. Fig. 10c 12 TOP 14 13 11 15 15a 2 1 6 M968550 REV. 1.5 8 CONNECT FRONT PANEL TO Fig. 11 ELECTRICAL BOX (DC POWER BATTERY); Fig. 11 1 1. Remove the four COVER SCREWS (1) and COVER (2) from ELECTRICAL BOX (3). Fig. 10. 2 TOP 3 2. Install BATTERY (4) into holder on DC circuit board. Press BATTERY (4) down (contacts facing downward) into position until tabs lock BATTERY (4) into place. 4 Fig. 11a 3. Attach the SAFETY CHAIN (5) from the FRONT PANEL (6) to the MOUNTING POST (7) as shown. Feed the Red and Black wires through the back opening in the ELECTRICAL BOX (3). Fig. 11a. TOP 3 4. Install the SENSOR WIRE GROMMET (11) into the COVER (2) as shown. Remove the SPLIT PLUG (11a) from SENSOR WIRE GROMMET (11). Insert SENSOR WIRE CONNECTOR (8) through SENSOR WIRE GROMMET (11). Insert SENSOR WIRE (9) into SPLIT PLUG (11a). Push SPLIT PLUG (11a) into SENSOR WIRE GROMMET (11) to seal. Fig. 11b. 7 6 5 BLACK & RED WIRES 8. Insert SENSOR WIRE CONNECTOR (8) into CIRCUIT BOARD RECEPTOR (10) slot. Fig. 11b. Fig. 11b 9. Replace COVER (2). Tighten COVER SCREWS (1) firmly. 8 1 TOP 10 9 11 11a 2 9 INSTALL FRONT PANEL; Fig. 12 Fig. 12 3 1. Install the two TABS (1) on the back side of FRONT PANEL (2) into the two SLOTS (3) located on the top edge of the ELECTRICAL BOX (4). Fig. 12. 1 2 TOP 4 2. Push on the bottom edge of the FRONT PANEL (2) until it snaps into place. If FRONT PANEL (2) will not snap into place, then loosen the MOUNTING SCREWS (6) on the ELECTRICAL BOX (4) slightly. Fig. 12. 3. To remove FRONT PANEL (2) insert WIRE KEY (5) (supplied) into the two holes located at the bottom of the FRONT PANEL (2). Push the WIRE KEY (5) up until it releases the bottom clips. Pull the bottom edge away and lift the FRONT PANEL (2) off. Fig. 12. 6 2 PUSH TO SNAP PANEL INTO PLACE 5 M968550 REV. 1.5 7 10 CONNECT OVERRIDE HOSES, Fig. 13 AC & DC POWER; Fig. 13 3 1. Push the BLACK HOSE (1) into the BOTTOM HOSE CONNECTOR (2) and the other end into the back of the OVERRIDE SWITCH (3). 1 BLACK HOSE 6 2. Push the BLUE HOSE (4) into the TOP HOSE CONNECTOR (5) on the valve and the other end into the BOTTOM CONNECTOR (6) on the OVERRIDE SWITCH (3). 4 BLUE HOSE 5 2 11 CONNECT SOLENOID WIRING Fig. 14 AND POWER SUPPLY; Fig. 14 1. Push the RED WIRE CONNECTOR (1) onto the SOLENOID PIN (2) with Red Stripe. Push the BLACK WIRE CONNECTOR (3) onto the other SOLENOID PIN (4). Push the wire connectors all the way down. 2. Code approved Electrical Outlet provided by others, (120V 50/60 Hz). 3. Plug AC POWER SUPPLY (5) into Outlet. RED WIRE 1 BLACK WIRE 3 RED STRIPE 2 4 5 ELECTRICAL OUTLET M968550 REV. 1.5 8 Fig. 15 Unit #1 TOP SENSOR WIRE 6 10 7 8 Unit #2 13 Unit #3 13 TOP SENSOR WIRE SENSOR WIRE 6 10 7 12 FOR AC-VERSION 6 10 7 8 12 TOP 8 12 Fig. 15a (MULTI HOOK-UP); Fig. 15, 15a SENSOR WIRE CONNECTOR Unit #1 1. Remove the COVER SCREWS (1) and COVER (2) from each ELECTRICAL BOX (3). TOP 2. See AC Version Electrical Hook-up for Unit #1 of the Multi hook-up. 5 3. Install SENSOR WIRE GROMMET (4) and FLUSH VALVE SENSOR WIRE (5) into the COVER (2) of each unit. Insert the flush valve sensor wire connector into the CENTER CIRCUIT BOARD RECEPTOR (6) on each unit. Fig. 15a. 4. Remove the SPLIT PLUG (7a) from the SENSOR WIRE GROMMET (7) on the left side of each ELECTRICAL BOX (3). 10 9 3 7a 2 5. Take the 10 ft. EXTENSION WIRE (8) from Unit #2 and insert one end of the EXTENSION WIRE CONNECTOR (9) through the SENSOR WIRE GROMMET (7) on left side of Unit #1. Insert EXTENSION WIRE (8) into SPLIT PLUG (7a). Push SPLIT PLUG (7a) into SENSOR WIRE GROMMET (7) to seal. Insert EXTENSION WIRE CONNECTOR (9) into LOWER CIRCUIT BOARD RECEPTOR (10). Fig. 15a. 6. Insert other end of EXTENSION WIRE (8) into SENSOR WIRE GROMMET (7) on left side of Unit #2. Insert that EXTENSION WIRE CONNECTOR (9) into the LOWER CIRCUIT BOARD RECEPTOR (10) of Unit #2. Fig. 15b. 6 4 7 1 8 FROM UNIT #2 Fig. 15b Unit #2 SENSOR WIRE CONNECTOR TOP 7. On Unit #2 ELECTRICAL BOX (3) remove ROUND KNOCK-OUT (11) on the bottom of the box by pressing a flathead screwdriver into the center of the ROUND KNOCK-OUT (11). Fig 15b. 8. Insert additional SENSOR WIRE GROMMET (12) included with Unit #2 into the knock-out opening in the bottom of the ELECTRICAL BOX (3). Take the 10 FT. EXTENSION WIRE (8) from Unit #3 and insert one end into the SENSOR WIRE GROMMET (12) in the bottom of the ELECTRICAL BOX (3) of Unit #2. Insert EXTENSION WIRE CONNECTOR (9a) into TOP CIRCUIT BOARD RECEPTOR (13) on Unit #2 . Fig. 15b. 9. Insert the other end of the EXTENSION WIRE (8) from Unit #3 into the SENSOR WIRE GROMMET (7) on the left side of Unit #3. Insert EXTENSION WIRE CONNECTOR (9) into LOWER CIRCUIT BOARD RECEPTOR (10) on Unit #3. 10. Repeat Steps 7 to 9 as necessary for additional Multi-AC Units. 11. Once all wire connections are made. Install the COVER (2) and COVER SCREWS (1) onto each ELECTRICAL BOX (3). 13 9a 10 9 2 3 7a 1 7 8 FROM UNIT #1 12 BACK OF BOX (3) 8 FROM UNIT #3 KNOCK-OUT (11), 11 REMOVE INSERT WIRE GROMMET (12) M968550 REV. 1.5 9 13 HOW TO INSTALL NEW BATTERY; Fig. 16 Fig. 16 4 1. Remove FRONT PANEL. For removing front panel see Step 9 for instructions. TOP 1 5 2. Remove the four COVER SCREWS (1) and COVER (2) from ELECTRICAL BOX (3). Fig. 16. 2 3 3. Disconnect GREY SENSOR WIRE (4) from CIRCUIT BOARD (5). 4. Remove CIRCUIT BOARD (5) from ELECTRICAL BOX (3). Fig. 16a. 5. With your thumbs, spread the two TABS (6) on battery holder apart and remove the BATTERY (7). Fig. 16a 2. Install NEW BATTERY (7) into holder on DC circuit board. Press BATTERY (7) down (contacts facing downward) into position until TABS (6) lock BATTERY (7) into place. TOP 3 6. Install CUIRCUIT BOARD (5) and connect GREY SENSOR WIRE (4). 7 7. Install COVER (2) and SCREWS (1). 5 8. Replace and FRONT PANEL. See Step 9 for instructions on installing front panel. 6 14 ADJUST SUPPLY STOP; Fig. 17 Fig. 17 IMPORTANT: To avoid overflowing, the SUPPLY STOP (2) must never be opened to the point where the flow from the valve exceeds the flow capacity of the fixture. The fixture must be able to handle a continuous flow in case of a flush valve failure. Valve is designed to provide stated flush volume with a 25 GPM flow rate. COUNTER-CLOCKWISE OPENS CONTROL STOP CLOCKWISE CLOSES CONTROL STOP 1. After installation is complete, peel off the PROTECTIVE FILM (1) from the sensor. Standing to one side, block the sensor with your hand for 10 seconds. Remove your hand and listen for audible “click” from within the valve. 2 1 2. Turn on SUPPLY STOP (2) 1/4 turn to 1/2 turn(CCW) and test for leaks. Note: Unit may flush for approximately 5 to 10 sec. when water is first turned on. If flow persists, turn water off and repeat step #1 above. 3. Actuate the FLUSH VALVE: A) Cover sensor with hand for 10 seconds. NOTE: Stand outside of sensor detection aera. B) Remove hand from in front of the sensor; unit will flush in approximately 3 seconds. 4. Adjust SUPPLY STOP (2) after each flush until the stated flush volume is achieved, no splashing occurs and the fixture is properly cleansed. 10 M968550 REV. 1.5 15 HOW TO SET DETECTION RANGE Fig. 18 (If Required) ; Fig. 18 & 19 5 Note: The detection distance is preset and is ideal for most installations. Should an adjustment be required follow the steps below. TOP 2 1. Remove FRONT PANEL (1). See Step 9 for removing front panel instructions. 6 3 2. Remove the four COVER SCREWS (2) and COVER (3) from ELECTRICAL BOX (4). Fig. 18. 4 3. Disconnect GREY SENSOR WIRE (5) from CIRCUIT BOARD. (6). 1 4. Keeping hands away from the front of the sensor, reconnect the GREY SENSOR WIRE (5) and quickly hang the FRONT PANEL (1) onto the ELECTRICAL BOX (4). Do not secure the FRONT PANEL (1) at this time. Note: You have 5 seconds after connecting cable to begin program process. 5 5. While the SENSOR CONTROL LED (6) is blinking slowly, place your hand 1 to 2 in. (30-50mm.) in front of the sensor. Fig. 19. 6. When the LED (6) stops blinking and stays "ON", move your hand to the desired position from sensor (detection zone, 15-3/4" to 31-1/2", 400 to 800mm ) and hold in place until the LED (6) begins to blink again. Fig. 19a. Note: Maximum Detection Zone is 15-3/4" to 31-1/2", (400 to 800mm ) from sensor. 7. Once the SENSOR CONTROL LED (6) begins to blink again, remove your hand from the detection zone. When the flashing stops, the detection distance is set. 9. Replace the FRONT PANEL (1). See Step 9 for instructions on installing front panel. 10. Actuate the FLUSH VALVE: A) Cover sensor with hand for 10 seconds. NOTE: Stand outside of sensor detection aera. B) Remove hand from in front of the sensor, unit will flush in approximately 3 seconds. 8. Replace COVER (3). Tighten COVER SCREWS (2) firmly. Fig. 19 Fig. 19a 6 BLINKING LED BLINKING LED MAXIMUM DETECTION ZONE 400mm TO 800mm (15-3/4" TO 31-1/2") 1" - 2" (30mm - 50mm) 11 M968550 REV. 1.5 12 M968550 REV. 1.5 NO NO 1. CLOSE STOP VALVE, 2. REPLACE SOLENOID KIT. 3. RE-ASSEMBLE AND INSTALL UNIT. 4. OPEN STOP VALVE. YES TEST SENSOR. DISCONNECT GRAY FLAT WIRE FROM CIRCUIT BOARD AND RE-CONNECT. SENSOR SHOULD FLASH FOR 5 SECONDS. DOES IT FLASH? NO LOOK FOR REPEATED DOUBLE FLASH ON SENSOR NO YES REPLACE SENSOR SEE STEP 13, page 10 in manual INSTALL NEW BATTERY RETRY AUTO FLUSH YES 1. COVER SENSOR FOR 10 SECONDS 2. UNCOVER SENSOR FOR 10 SECONDS. DOES THE UNIT STOP FLUSHING? NO MANUAL VALVE OBSTRUCTED. CLOSE STOP VALVE AND SERVICE NO REPLACE SOLENOID KIT REPLACE SENSOR PUSH MANUAL FLUSH BUTTON; DOES IT RETURN? UNIT IS CONTINUOUSLY FLUSHING RETRY AUTOMATIC FLUSH; WAS IT SUCCESSFUL? YES DOES THE SENSOR FLASH FOR THE FIRST 5 SECONDS? SEE STEP 13, page 10 in manual NO YES REPLACE BATTERY SEE STEP 13, page 10 in manual SEE STEP 13, page 10 in manual BATTERY LOW; REPLACE BATTERY Product n ames lis te d h e re i n a re tra d e m a rk s o f A S A m e ri ca , I n c. IN CANADA 1-800-387-0369 (TORONTO 1-905-306-1093) Weekdays 8:00 a.m. to 7:00 p.m. EST HOT LINE FOR HELP For toll-free information and answers to your questions, call: 1 (800) 442-1902 Weekdays 8:00 a.m. to 6:00 p.m. EST IN MEXICO 01-800-839-12-00 TROUBLESHOOTING FLOW CHARTS CLOSE STOP VALVE, REPLACE SOLENOID KIT. RE-ASSEMBLE & INSTALL UNIT. OPEN STOP VALVE. NO RETRY AUTOMATIC FLUSH. YES TEST SENSOR. DISCONNECT GRAY FLAT WIRE FROM CIRCUIT BOARD AND RE-CONNECT. SENSOR SHOULD FLASH FOR 5 SECONDS. DOES IT FLASH? RETRY AUTOMATIC FLUSH. DOES THE UNIT FLUSH? 1. COVER SENSOR FOR 10 SECONDS 2. UNCOVER SENSOR FOR 10 SECONDS. NO LOOK FOR REPEATED DOUBLE FLASH ON SENSOR INSTALL NEW BATTERY or PLUG-IN AC POWER SUPPLY REPLACE PISTON KIT INSTALL NEW BATTERY OPEN VALVE NO NO YES NO UNIT WILL ONLY FLUSH MANUALLY YES TRY MANUAL VALVE BUTTON; WILL THE UNIT FLUSH? NO LOOK FOR REPEATED DOUBLE FLASH ON SENSOR YES IS STOP VALVE OPEN? UNIT DOES NOT FLUSH AT ALL SELECTRONIC™ PROXIMITY TOILET CONCEALED FLUSH VALVE 1.28 & 1.6 GPF A922267-0070A ROUND GROMMET MODEL NUMBERS A908171-0021280A COVER (1.28 gpf) A922290-0070A POWER SUPPLY GROMMET 6065.22X 6065.26X 6067.22X 6067.26X 6068.22X 6068.26X A908171-0021600A COVER (1.6 gpf) M962745-0070A ELECTRICAL BOX ASSEMBLY M962746-0020A MANUAL VALVE M962748-0070A SENSOR MTG. BRACKET TOP A950223-0071600A SENSOR FOR FLUSH VALVE WITH 1.6 gpf M950169-0070A POWER SUPPLY A950223-0071280A SENSOR FOR FLUSH VALVE WITH 1.28 gpf M962747-0070A COVER WITH SCREWS A950489-0070A CIRCUIT BOARD AC & MULTI AC A922270-0070A “U” KEY FOR COVER M962749-0070A CHAIN ASSEMBLY A906680-0070A BONNET NUT A923654-0070A BATTERY 6VCR-P2 M962956-0070A SOLENOID & PISTON SUBASSEMBLY M962664-0070A SOLENOID ASSEMBLY A950487-0070A CIRCUIT BOARD DC M955059-0020A ADJUSTABLE TAILPIECE M962663-0070A PISTON ASSEMBLY A922265-0070A 10 ft. MULTI EXTENSION WIRE (for 6057 series only) M962754-0070A SUPPLY STOP M962751-0070A VACUUM BREAKER ASSEMBLY A905416-0070A SOLDER ADAPTER M962752-0020A SLIP JOINT COUPLING M962996-0020A WASHER AND SUPPORT KIT M962750-0070A MANUAL VALVE HOSE KIT A919882-0020A OUTLET PIPE A901978-0020A ELBOW A901978-0070A ELBOW M962751-0070A VACUUM BREAKER ASSEMBLY M962751-0070A VACUUM BREAKER ASSEMBLY M962752-0020A SLIP JOINT COUPLING M962752-0020A SLIP JOINT COUPLING M962752-0020A SLIP JOINT COUPLING M962996-0020A WASHER AND SUPPORT KIT A901978-0070A ELBOW A908186-0020A ESCUTCHEON A919882-0020A OUTLET PIPE A901978-0070A ELBOW A919882-0020A OUTLET PIPE M962996-0020A WASHER AND SUPPORT KIT A908186-0020A ESCUTCHEON A919882-0020A OUTLET PIPE M962996-0020A WASHER AND SUPPORT KIT HOT LINE FOR HELP M962048-0020A SPUD COUPLING For toll-free information and answers to your questions, call: 1-800-442-1902 Weekdays 8:00 a.m. to 6:00 p.m. EST IN CANADA 1-800-387-0369 (TORONTO 1-905-306-1093) Weekdays 8:00 a.m. to 7:00 p.m. EST IN MEXICO 01-800-839-1200 M962953-0020A SPUD COUPLING KIT Product names listed herein are trademarks of American Standard Inc. © AS America, Inc. 2009 13 M962953-0020A SPUD COUPLING KIT M968550 REV. 1.5