Download Renesas SuperH SH7710 E10A Technical information
Transcript
2.2.7 Performance Measurement Function The emulator supports the performance measurement function. 1. Setting the performance measurement conditions To set the performance measurement conditions, use the [Performance Analysis] dialog box and the PERFORMANCE_SET command. When any line on the [Performance Analysis] window is clicked with the right mouse button, the popup menu is displayed and the [Performance Analysis] dialog box is displayed by selecting [Setting]. Note: For the command line syntax, refer to the online help. (a) Specifying the measurement start/end conditions The measurement start/end conditions are specified in the [Mode] drop-down list box in the [Performance Analysis] dialog box. Three conditions can be set as shown in table 2.8. Table 2.8 Conditions Specified in [Mode] Item Description Normal break Measurement is started by executing a program and ended when a break condition is satisfied. Break Condition 1 -> 2 Measurement is started from the satisfaction of the condition set in Break Condition 1 to the satisfaction of the condition set in Break Condition 2. Break Condition 2 -> 1 Measurement is started from the satisfaction of the condition set in Break Condition 2 to the satisfaction of the condition set in Break Condition 1. 27