Download Mendota FV44i Operating instructions
Transcript
MENDOTA FV-44i GAS DIRECT VENT FIREPLACE INSERT SPECIFICATIONS & CLEARANCES Minimum Allowable Fireplace Opening: 34” wide X 24” high X 17” Deep 34 24 FV-44i Faceplate Dimensions A 14 1/2 16 1/2 11 1/2 1 2 1/2 TOP VIEW 18” MIN CLEARANCE 8 “ MIN. CLEARANCE COMBUSTIBLE MANTEL No Trim With Black or Brass Trim B Inches 31 33 36 31 1/16 mm. 788 838 914 792 Inches 44 48 52 44 1/8 mm. 1118 1220 1321 1122 33 36 843 920 48 1/8 52 1/8 1224 1326 1/16 1/16 TRIM The solid-fuel fireplace chimney must be clean and in good working order and is constructed on non-combustible materials 12” MIN‐TOP OF VENT SLOT TO BOTTOM OF MANTEL Chimney cleanouts must fit properly. “A” “D” 23 1/2 33 1/4 FRONT VIEW “D” “B” 8” MAX @ 12” ABOVE HEAT OUTLET COMBUSTIBLE MANTEL 1/2 14 1/2 11 1/2 4” VENT PIPE 3” VENT PIPE The refractory, glass doors, screen, and log grates can be removed from the solid-fuel fireplace to accommodate the gas insert. Smoke shelves, shields, and baffles can be removed if attached with mechanical fasteners. Trim panels and surrounds shall not seal ventilation openings in the fireplace. WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury. Cutting of any sheet metal parts on the solidfuel fireplace is prohibited. 25 1/4 22 1/2 23 3/4 NOTE: Installer must attach the sup‐ plied warning label, included in the instruction packet, to the inside of the fireplace before installing insert. 16 “ MIN. NON‐COMBUSTIBLE HEARTH EXTENSION SIDE VIEW 6