Download Troubleshooting Guide - Rorke Data
Transcript
Message What Happened? What to Do? Message What Happened? What to Do? Message What Happened? What to Do? Message What Happened? What to Do? Message What Happened? What to Do? Message What Happened? What to Do? Message What Happened? What to Do? Message 34 Peripheral Device ALERT: Elevated Temperature Alert High temperature threshold violated and detected through an I2C serial bus. Insufficient cooling at the installation site or cooling fan failure might have caused the situation. Correct your installation site ambient condition and cooling fan failure. Contact your RAID system supplier if a replacement is necessary. Peripheral Set 0 Device ALERT: Backplane Temperature Failure Detected (error code) Temperature sensor on the backplane has failed or reported erroneous readings. Contact your RAID system supplier. Peripheral Set 0 Device ALERT: Backplane Temperature Not Present (error code) IIC bus lost contact with the backplane sensor. Contact your RAID system supplier. Peripheral Set 0 Device ALERT: Temperature Sensor 0 Not Present Temperature sensor failed or serial bus configuration/connection faults occurred. Contact your RAID system supplier. Peripheral Set 0 Device ALERT: Cold Detected (X.X(C)) (error code) Temperature dropped below the lower system threshold detected. Improper installation site condition might have caused the situation. Correct your installation site condition. Contact your RAID system supplier. Peripheral Set 0 Device ALERT: Hot Detected (X.X(C)) (error code) Temperature rises above the higher system threshold detected. Improper installation site condition or cooling fan failure might have caused the situation. Correct your installation site condition. Contact your RAID system supplier. SES(C0 I0)Power Supply X: Device Not Supported! Unrecognizable device type. This event may result from an incorrect configuration with the SES remote device monitoring. You might have inserted a wrong type of PSU from a similar Galaxy model. PSUs for different Galaxy models may look similar. Check proper module installation and contact your RAID system supplier. SES(C0 I0)Cooling Fan X: Device Not Supported! Galaxy DS