34
Peripheral Device ALERT: Elevated Temperature Alert
High temperature threshold violated and detected through an I2C
serial bus. Insufficient cooling at the installation site or cooling fan
failure might have caused the situation.
Correct your installation site ambient condition and cooling fan
failure. Contact your RAID system supplier if a replacement is
necessary.
Peripheral Set 0 Device ALERT: Backplane Temperature Failure
Detected (error code)
Temperature sensor on the backplane has failed or reported
erroneous readings.
Contact your RAID system supplier.
Peripheral Set 0 Device ALERT: Backplane Temperature Not
Present (error code)
IIC bus lost contact with the backplane sensor.
Contact your RAID system supplier.
Peripheral Set 0 Device ALERT: Temperature Sensor 0 Not
Present
Temperature sensor failed or serial bus configuration/connection
faults occurred.
Contact your RAID system supplier.
Peripheral Set 0 Device ALERT: Cold Detected (X.X(C)) (error
code)
Temperature dropped below the lower system threshold detected.
Improper installation site condition might have caused the
situation.
Correct your installation site condition. Contact your RAID system
supplier.
Peripheral Set 0 Device ALERT: Hot Detected (X.X(C)) (error
code)
Temperature rises above the higher system threshold detected.
Improper installation site condition or cooling fan failure might
have caused the situation.
Correct your installation site condition. Contact your RAID system
supplier.
SES(C0 I0)Power Supply X: Device Not Supported!
Unrecognizable device type. This event may result from an
incorrect configuration with the SES remote device monitoring.
You might have inserted a wrong type of PSU from a similar
Galaxy model. PSUs for different Galaxy models may look similar.
Check proper module installation and contact your RAID system
supplier.
SES(C0 I0)Cooling Fan X: Device Not Supported!
Galaxy DS