Download Distributed I/O 2006
Transcript
Sold by AA Electric 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com Distributed I/O Overview 338 CC-Link Overview 339 CC-Link Remote I/O 343 CC-Link Analog Modules 376 CC-Link Special Function I/O 388 Profibus-DP I/O Modules 398 Profibus-DP I/O Analog Modules 402 CC-Link/LT Overview 404 CC-Link/LT Screw Terminal Modules 406 CC-Link/LT Spring Clamp Modules 408 CC-Link/LT e-CON Modules 409 CC-Link/LT MIL Connector Modules 411 CC-Link/LT Cable Type Modules 412 CC-Link/LT Accessories 415 I/O Link Modules 416 Dimensional Drawings 417 Mitsubishi Electric Automation | Distributed I/O 337 Control Level: MELSECNET/H, NET/10, NET/II, NET/B These Mitsubishi Electric control level networks allow controller to controller networking, plus the ability to place regular rack based I/O on a network link that operates up to 25Mbit/s. A network node of remote I/O uses a standard controller base with a remote I/O network adapter in place of a CPU. As a standard base unit is used, any type of regular rack based I/O or special function module may be used. This gives tremendous flexibility for configuring remote I/O nodes. For more details on modules available, please refer to the relevant Q, QnA, AnS or A Series controller sections. Note that in general, a remote I/O network is a separate network segment to a controller network. Device Level: CC-Link CC-Link is a high performance, open device level network that operates up to 10Mbit/s. Mitsubishi Electric offers extensive support for this network, with a wide variety of I/O and special function modules that sit directly on the network, under the control of a Q, QnA, AnS/QnAS, A or FX2N Supermicro Series controller. This section presents the I/O and special function modules available, divided into device types. For information on other Mitsubishi Electric automation products that support CC-Link, please refer to the other controller, HMI, VFD and Servo sections of this publication. Profibus-DP Profibus-DP is an alternative open device level network also widely supported by Mitsubishi Electric . This section presents the I/O choices available. For information on other Mitsubishi Electric automation products that support Profibus, please refer to the other controller, HMI & VFD sections of this publication. Sensor Level: CC-Link/LT CC-Link/LT is a sensor level version of CC-Link. It offers a way to simply connect discrete I/O to a controller with a minimum of installation and labor costs. CC-Link/LT uses a special “vampire” style connection technology to make device connections with no cutting or stripping of cable. I/O Link I/O link is a standalone Mitsubishi Electric network that handles small quantities of digital I/O on a twisted pair connection. I/O Link is easy to program and install and is supported by most of our controllers. 338 Sold by AA Electric 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com n DISTRIBUTED I/O In addition to our controllers, Mitsubishi Electric can offer you the capability to add a broad range of I/O to allow you to place I/O points close to where they are required on your machine or line. We offer three main approaches to putting I/O on a network: Q Series Controller A/QnA Series Controller A500 AC Drives FX2N Supermicro Controller GOT HMI 3rd Party Devices D75 Dual Axis Motion Controller e Third Party Devices: Sensors, Valves, Etc. MR-J2/Motor Servo Amp el Laptop PC Remote Modules: I/O, Analog, HighSpeed Controllers, RTD, Etc. De vic Remote Program Interface Lev Sold by AA Electric 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com Supervisory PC AnSH/QnASH Series Controller Solution CC-Link Control and Communication Link (CC-Link) is an open network administered as a fully open architecture by the CC-Link Partner Association (CLPA). Currently over 300 vendors are manufacturing products for it. CC-Link was designed from the outset as a “flat” network. This means it offers both high speed response of I/O performance, but also high volumes of data communication as required in more complex distributed systems. CC-Link guarantees a full 10Mbit/s performance across the whole network, regardless of device type, eliminating hidden bottle necks, common with other open systems. While configuration software is not mandatory, CC-Link Configurator offers an intuitive, graphical network configuration tool for setting up and troubleshooting a system. Our standard GX Developer development suite also includes built-in configuration tools for CC-Link. CC-Link offers you the widest choices for integrating a wide variety of automation components into a single, seamless automation system. We can offer a system that can include any of the following items on the network: p p p p p p p p p Master or local controllers (Q, QnA, QnASH, AnSH, A, FX) GOT HMI E and A500 VFD Discrete I/O (in a wide variety of types and configurations) Analog I/O High speed counters Motion control RTD/Thermocouple modules PC stations via PC-link cards Mitsubishi Electric Automation | Distributed I/O 339 This section presents the current line-up of CC-Link I/O blocks and special function modules. For network master modules, please refer to the appropriate controller section. Before using this guide, please read the following guide to nomenclature: Guide to CC-Link I/O Nomenclature Generic part number format Note on “1-wire”, “2-wire”, “3-wire” & “4-wire” terminology Throughout the CC-Link blocks, we reference these terms. These are concise definitions for the following ways to connect I/O devices: • 1 wire: One side of the load is connected to the I/O module terminal block. The other side is connected to a common terminal shared by all devices. • 2 wire: One side of the load is connected to the I/O module terminal block. The other side is connected to a dedicated common terminal for that load on the terminal block. Note that in some cases, the common terminals may be connected internally. • 3 wire: The I/O block is configured to accept loads with three connections (such as various types of sensor, etc) • 4 wire: As three wire, but configured for four connection devices. Note on connector types Various different types of connector styles are available on the CC-Link blocks, as follows: NOTE: IN GENERAL, BLOCKS ARE NOT SUPPLIED WITH CONNECTORS AND ACCESSORIES (IF REQUIRED). PLEASE INSURE YOU HAVE ALL NECESSARY CONNECTORS BEFORE BEGINNING AN INSTALLATION. • Screw terminals: These are conventional screw terminals. Note that all wiring will require cutting, stripping, and terminating with a crimped spade or ring type lug to insure a reliable connection. • FCN connector: These are 40 pin connectors that allow fast connection and disconnection of a whole group of I/O in one action. The following types of FCN connector are available: Model Number A6CON1 A6CON2 A6CON3 340 Certification UL • cUL UL • cUL UL • cUL Number of Pins 40 40 40 Wiring Type Solder Crimp IDC Connector Type FCN FCN FCN Sold by AA Electric 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com n DISTRIBUTED I/O Guide to CC-Link I/O and Special Function Modules Sold by AA Electric 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com One Touch Connector (OTC): OTC offer significant installation and maintenance benefits as follows: • IDC (insulation displacement connector) type connection avoids need for stripping or terminating wiring with lugs. Simply cut wiring to length, insert into connector and snap shut to make a reliable connection. These are available for I/O, network & power connections. • Easily connected and disconnected individually or in groups to assist maintenance • Compact design minimizes I/O block size • Available in a variety of wiring gauge sizes and colors for identification • Shipped in boxes of 20 connectors; divide quantity required by 20, then round up to next whole number for correct order quantity. Model Number Gauge Size (AWG) Color Qty. Per Box Comments A6CON-P214 26-24 Transparent 20 For I/O A6CON-P220 26-24 Yellow 20 For I/O A6CON-P514 22-20 Red 20 For I/O A6CON-P520 22-20 Blue 20 For I/O • Waterproof M12 connectors: Selected I/O blocks are available in an IP67 waterproof format. These use connectors that use a M12 metric threaded connector to make all connections. Benefits include: • Water tight connections for installations where exposure to liquids is required • In some installations, these blocks may be mounted directly on a machine without the need for an enclosure, reducing system cost. • Miscellaneous accessories: The following accessories are also available: Note the quantity per box and calculate the correct order quantity accordingly. Model Number Quantity Per Box BA1SJ61-S N/A Comments Three conductor, CLPA certified, signal only CC-Link cable. Sold by the meter. BA1SJ61-P N/A Five conductor, CLPA certified, signal and power CC-Link cable. Sold by the meter. A6CON-L5P 10 OTC network connector A6CON-PW5P 10 OTC network connector A6CON-LJ5P 5 OTC Network on-line connector (1) A6CON-PWJ5P 5 OTC Power on-line connector (2) A6CON-TR11 1 Terminating resistor (3) A6CAP-DC1 20 Dust cap to protect unused connectors on IP67 modules (4) A6CAP-WP1 20 Metal waterproof cap to protect unused connectors on IP67 modules (4) A6CAP-WP2 20 Plastic waterproof cap to protect unused connectors on IP67 modules (4) A6PLT-J65V1 1 DIN rail mount for vertical format blocks (single width) A6PLT-J65V2 1 DIN rail mount for vertical format blocks (double width) BKO-C8834H12 2 x 110 ohm, 2 x 130 ohm BKO-C10798H02 1 CC-Link terminating resistors with insulating lugs QJ61BT11 network terminal block assembly Notes: 1. This connector accepts two A6CON-L5P and plugs into a CC-Link module. Its function is to allow a network connection to be connected/disconnected via a single operation, and maintains the network connection. Note these are only used with "VBT" type modules. 2. Accepts two A6CON-PW5P and performs the same function as A6CON-LJ5P for power. Use only with "VBT" modules. 3. Required at the end of a network segment for reliable communication for "VBT" modules. 4. AJ65FBT & AJ65SBTW4 type modules Mitsubishi Electric Automation | Distributed I/O 341 Model Number Description Contents Included? SH(NA)4007 CC-Link System Compact Type Remote I/O Module Covers all CC-Link digital I/O blocks No (purchase separately) SH(NA)3614 AJ65BT-64AD Analog Digital Converter Module User’s Manual Covers AJ65BT-64AD No (purchase separately) IB(NA)66748 AJ65BT-64AD Analog Digital Converter Module User’s Manual (Hardware) Covers basic features of the AJ65BT-64AD Yes SH(NA)3615 AJ65BT-64DAV/DAI Digital Analog Conversion Module User’s Manual Covers AJ65BT-64DAV & 64DAI No (purchase separately) SH(NA)080107 AJ65SBT-62DA Digital-Analog Converter Module User’s Manual Covers AJ65SBT-62DA No (purchase separately) IB(NA)0800139 AJ65SBT-62DA Digital-Analog Converter Module User’s Manual (Hardware) Covers basic features of the AJ65BT-62DA Yes SH(NA)080106 AJ65SBT-64AD Analog-Digital Converter Module User’s Manual Covers AJ65SBT-64AD No (purchase separately) Covers basic features of the AJ65SBT-64AD Yes Covers AJ65VBTCU-68ADV & 68ADI No (purchase separately) Covers basic features of the AJ65VBTCU-68ADV & 68ADI Yes AJ65VBTCU-68DAV Digital-Analog Converter Module User’s Manual Covers AJ65VBTCU-68DAV No (purchase separately) AJ65VBTCU-68DAV Digital-Analog Converter Module User’s Manual (Hardware) AJ65BT-64RD3/-64RD4 Pt100 Temperature Input Module User’s Manual AJ65BT-64RD3/-64RD4 Pt100 Temperature Input Module User’s Manual (Hardware) Covers basic features of the AJ65VBTCU-68DAV Yes Covers AJ65BT-64RD3/-64RD4 No (purchase separately) Covers basic features of the AJ65BT-64RD3 & 64RD4 Yes AJ65BT-68TD Thermocouple Input Module User’s Manual (Hardware) Covers AJ65BT-68TD Yes AJ65BT-D62/D62D/D62D-S1 High Speed Counter Module User’s Manual AJ65BT-D62/D62D/D62D-S1 High Speed Counter Module User’s Manual (Hardware) Covers all CC-Link high speed counter modules Covers basic features of high speed counter modules IB(NA)66824 AJ65BT-D75P2-S3 Positioning Module User’s Manual Covers AJ65BT-D75P2-S3 IB(NA)66829 AJ65BT-D75P2-S3 Positioning Module User’s Manual (Hardware) Covers basic features of the AJ65BT-D75P2-S3 Yes IB(NA)66781 AJ65BT-R2 RS232 Interface Module User’s Manual Covers AJ65BT-R2 No (purchase separately) IB(NA)66780 AJ65BT-R2 RS232 Interface Module User’s Manual (Hardware) Covers basic features of the AJ65BT-R2 Yes SH(NA)080105 AJ65BT-G4-S3 Peripheral Connection Module User’s Manual Covers AJ65BT-G4-S3 No (purchase separately) IB(NA)0800137 AJ65BT-G4-S3 Peripheral Connection Module User’s Manual (Hardware) Covers basic features of the AJ65BT-G4-S3 Yes IB(NA)0800251 Analog-Digital Converter Module User’s Manual (Hardware) AJ65VBTCU-68ADVN/ADIN Covers basic features of the AJ65VBTCU68ADVN/ADIN Yes SH(NA)080401 Analog-Digital Converter Module Type AJ65VBTCU-68ADVN/ADIN User’s Manual Covers AJ65VBTCU-68ADVN and AJ65VBTCU-68ADIN No (purchase separately) IB(NA)8000252 Digital-Analog Converter Module User’s Manual (Hardware) AJ65VBTCU-68DAVN Covers basic features of the AJ65VBTCU68DAVN Yes SH(NA)080402 Digital-Analog Converter Module Type AJ65VBTCU-68DAVN User’s Manual Covers AJ65VBTCU-68DAVN No (purchase separately) IB(NA)0800240 AJ65SBT-CLB CC-Link-CC-Link/LT Bridge Module User’s Manual (Hardware) Contains basic information on the bridge module Yes SH(NA)080362 AJ65SBT-CLB CC-Link-CC-Link/LT Bridge Module User’s Manual Covers the bridge module No (purchase separately) IB(NA)0800138 SH(NA)080181 IB(NA)0800200 SH(NA)080182 IB(NA)0800201 SH(NA)4001 IB(NA)66831 IB(NA)66830 IB(NA)66823 IB(NA)66822 AJ65SBT-64AD Analog-Digital Converter Module User’s Manual (Hardware) AJ65VBTCU-68ADV/ADI Analog-Digital Converter Module User’s Manual AJ65VBTCU-68ADV/ADI Analog-Digital Converter Module User’s Manual (Hardware) Note: Many of these manuals are available by free download from our website, www.meau.com 342 No (purchase separately) Yes No (purchase separately) Sold by AA Electric 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com n DISTRIBUTED I/O Required Manuals Sold by AA Electric 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com CC-Link Remote I/O: AJ65SBTBo-o• AJ65BTBo-o Screw Terminal Block Type AJ65SBTBo-o/AJ65BTBo-o • Screw Terminals n Widest range of I/O types in CC-Link I/O product line. n AJ65BTBo-o types equipped with removable terminal blocks. n AJ65SBTBo-o offer most efficient use of panel space. n All models UL • cUL listed and CE certified. Finger protector Sprung screw retracts to insert wiring lug Terminal block Performance Specifications Operating Voltage ON Voltage OFF Voltage AJ65SBTB1-8D DC input +COM/–COM common type 8 points Photocoupler 24 VDC 14 V min. 6 V max. Input Response Time OFF—ON ON—OFF 1.5 ms max. 1.5 ms max. One wire type 8 points 1 common 30mA AJ65SBTB1-16D DC input +COM/–COM common type 16 points Photocoupler 24 VDC 14 V min. 6 V max. 1.5 ms max. 1.5 ms max. One wire type 16 points 1 common 35mA AJ65SBTB1-16D1 DC input +COM/–COM common type 16 points Photocoupler 24 VDC 15 V min. 3 V max. 0.2 ms max. 0.2 ms max. One wire type 16 points 1 common 40mA AJ65SBTB1-32D DC input +COM/–COM common type 32 points Photocoupler 24 VDC 14 V min. 6 V max. 1.5 ms max. 1.5 ms max. One wire type 32 points 1 common 45mA AJ65SBTB1-32D1 DC input +COM/–COM common type 32 points Photocoupler 24 VDC 15 V min. 3 V max. 0.2 ms max. 0.2 ms max. One wire type 32 points 1 common 50mA AJ65SBTB2N-8A AC input — 8 points Photocoupler 100 to 120 VAC 80 V min. 30 V max. 20 ms max. 20 ms max. Two wire type 8 points 1 common 35mA AJ65SBTB2N-16A AC input — 16 points Photocoupler 100 to 120 VAC 80 V min. 30 V max. 20 ms max. 20 ms max. Two wire type 16 points 1 common 40mA AJ65SBTB3-8D DC input +COM/–COM common type 8 points Photocoupler 24 VDC 14 V min. 6 V max. 1.5 ms max. 1.5 ms max. Three wire type 8 points 1 common 40mA AJ65SBTB3-16D DC input +COM/–COM common type 16 points Photocoupler 24 VDC 14 V min. 6 V max. 1.5 ms max. 1.5 ms max. Three wire type 16 points 1 common 45mA AJ65BTB1-16D DC input +COM/–COM common type 16 points Photocoupler 24 VDC 14 V min. 6 V max. 10 ms max. 10 ms max. One wire type 16 points 1 common 60mA AJ65BTB2-16D DC input +COM/–COM common type 16 points Photocoupler 24 VDC 14 V min. 6 V max. 10 ms max. 10 ms max. Two wire type 16 points 1 common Input Module Model Name Output Module Model Name Input Type Number of Input Points Isolation Method Rated Input Voltage Number of Output Points Isolation Method Rated load Voltage Maximum Load Current Output Response Time External Connection Internal Current Common Connection Wire Type Consumption 60mA Surge Suppression External Connection Wire Type Common Connection Internal Current Consumption 1 Point 1 Common OFF—ON ON—OFF Leakage Current AJ65SBTB1-8T Transistor output Sink type 8 points Photocoupler 12/24 VDC 0.5A 2.4A 0.5 ms max. 1.5 ms max. 0.25 mA max. Zener diode One wire type 8 pts 1 com 35mA AJ65SBTB1-8T1 Transistor output Sink type 8 points Photocoupler 12/24 VDC 0.5A 2.4A 0.5 ms max. 1.5 ms max. 0.1 mA max. Zener diode One wire type 8 pts 1 com 35mA AJ65SBTB1-16T Transistor output Sink type 16 points Photocoupler 12/24 VDC 0.5A 3.6A 0.5 ms max. 1.5 ms max. 0.25 mA max. Zener diode One wire type 16 pts 1 com 50mA AJ65SBTB1-32T Transistor output Sink type 32 points Photocoupler 12/24 VDC 0.5A 4.8A 0.5 ms max. 1.5 ms max. 0.25 mA max. Zener diode One wire type 32 pts 1 com 65mA AJ65SBTB1-16T1 Transistor output Sink type 16 points Photocoupler 12/24 VDC 0.5A 3.6A 0.5 ms max. 1.5 ms max. 0.1 mA max. Zener diode One wire type 16 pts 1 com 50mA AJ65SBTB1-32T1 Transistor output Sink type 32 points Photocoupler 12/24 VDC 0.5A 4.8A 0.5 ms max. 1.5 ms max. 0.1 mA max. Zener diode One wire type 32 pts 1 com 65mA AJ65SBTB1-8TE Transistor output Source type 8 points Photocoupler 12/24 VDC 0.1A 0.8A 0.5 ms max. 1.5 ms max. 0.1 mA max. Zener diode One wire type 8 pts 1 com 35mA AJ65SBTB1-16TE Transistor output Source type 16 points Photocoupler 12/24 VDC 0.1A 1.6A 0.5 ms max. 1.5 ms max. 0.1 mA max. Zener diode One wire type 16 pts 1 com 50mA AJ65SBTB2-8T Transistor output Sink type 8 points Photocoupler 12/24 VDC 0.5A 2.4A 0.5 ms max. 1.5 ms max. 0.25 mA max. Zener diode Two wire type 8 pts 1 com 45mA AJ65SBTB2-16T Transistor output Sink type 16 points Photocoupler 12/24 VDC 0.5A 3.6A 0.5 ms max. 1.5 ms max. 0.25 mA max. Zener diode Two wire type 16 pts 1 com 55mA AJ65SBTB2-8T1 Transistor output Sink type 8 points Photocoupler 12/24 VDC 0.5A 2.4A 0.5 ms max. 1.5 ms max. 0.1 mA max. Zener diode Two wire type 8 pts 1 com 45mA AJ65SBTB2-16T1 Transistor output Sink type 16 points Photocoupler 12/24 VDC 0.5A 3.6A 0.5 ms max. 1.5 ms max. 0.1 mA max. Zener diode Two wire type 16 pts 1 com 55mA AJ65SBTB2N-8R Relay output — 8 points Relay 24 VDC/240 VAC 2A 4A 10 ms max. 12 ms max. — None Two wire type 8 pts 1 com 85mA AJ65SBTB2N-16R Relay output — 16 points Relay 24 VDC/240 VAC 2A 8A 10 ms max. 12 ms max. — None Two wire type 16 pts 1 com 120mA AJ65SBTB2N-8S Triac output — 8 points Photocoupler 100 to 240 VAC 0.6A 2.4A 1 ms max. 1/2c + 1 ms max. — C-R absorber Two wire type 8 pts 1 com 55mA AJ65SBTB2N-16S Triac output — 16 points Photocoupler 100 to 240 VAC 0.6A 4.8A 1 ms max. 1/2c + 1 ms max. — C-R absorber Two wire type 16 pts 1 com 85mA AJ65BTB1-16T Transistor output Sink type 16 points Photocoupler 12/24 VDC 0.5A 4A 2 ms max. 2 ms max. 0.1 mA max. Zener diode One wire type 8 pts 1 com 80mA AJ65BTB2-16R Relay output — 16 points Relay 24 VDC/240 VAC 2A 8A 10 ms max. 12 ms max. — None Two wire type 8 points 1 com 85mA AJ65BTB2-16T Transistor output Sink type Output Type Combined I/O Module Model Name I/O Type DC input /trans output DC input AJ65SBTB1-16DT1 /trans output DC input AJ65SBTB1-16DT2 /trans output DC input AJ65SBTB1-16DT3 /trans output DC input AJ65SBTB1-32DT /trans output DC input AJ65SBTB1-32DT1 /trans output DC input AJ65SBTB1-32DT2 /trans output DC input AJ65SBTB1-32DT3 /trans output DC input AJ65SBTB32-8DT /trans output DC input AJ65SBTB32-8DT2 /trans output DC input AJ65SBTB32-16DT /trans output DC input AJ65SBTB32-16DT2 /trans output DC input AJ65BTB1-16DT /trans output DC input AJ65BTB2-16DT /trans output AJ65SBTB1-16DT AJ65BTB2-16DR DC input /relay output +COM type/sink type +COM type/sink type +COM type/sink type +COM type/sink type +COM type/sink type +COM type/sink type +COM type/sink type +COM type/sink type +COM type/sink type +COM type/sink type +COM type/sink type +COM type/sink type +COM type/sink type +COM type/sink type +COM/–COM common type/– 4A 0.5A 2 ms max. 2 ms max. 0.1 mA max. 12/24 VDC 16 points Photocoupler Number Isolation Input Maximum Load Current Operating Voltage Output Response Time Input/Load of I/O Response Method Voltage 1 Point 1 Common ON Voltage OFF Voltage OFF—ON Points Time ON—OFF 8 pts /8 pts 8 pts /8 pts 8 pts /8 pts 8 pts /8 pts 16 pts /16 pts 16 pts /16 pts 16 pts /16 pts 16 pts /16 pts 4 pts /4 pts 4 pts /4 pts 8 pts /8 pts 8 pts /8 pts 8 pts /8 pts 8 pts /8 pts Photocoupler / photocoupler Photocoupler / photocoupler Photocoupler / photocoupler Photocoupler / photocoupler Photocoupler / photocoupler Photocoupler / photocoupler Photocoupler / photocoupler Photocoupler / photocoupler Photocoupler / photocoupler Photocoupler / photocoupler Photocoupler / photocoupler Photocoupler / photocoupler Photocoupler / photocoupler Photocoupler / photocoupler 8 pts /8 pts Photocoupler /relay Zener diode Leakage Current Two wire type 80mA 8 pts 1 com Connection Internal Surge Common Wire Type on Current Suppression Input/Output Sides Connection Consumption 24VDC/24VDC 1.5 ms max. 0.5A 2.4A 14 V min. 6 V max. 0.5 ms max. 1.5 ms max. 0.25 mA max. Zener diode 24VDC/24VDC 0.2 ms max. 0.5A 2.4A 15 V min. 3 V max. 0.5 ms max. 1.5 ms max. 0.25 mA max. Zener diode 24VDC/24VDC 1.5 ms max. 0.5A 2.4A 14 V min. 6 V max. 0.5 ms max. 1.5 ms max. 0.1 mA max. Zener diode 24VDC/24VDC 0.2 ms max. 0.5A 2.4A 15 V min. 3 V max. 0.5 ms max. 1.5 ms max. 0.1 mA max. Zener diode 24VDC/24VDC 1.5 ms max. 0.5A 3.6A 14 V min. 6 V max. 0.5 ms max. 1.5 ms max. 0.25 mA max. Zener diode 24VDC/24VDC 0.2 ms max. 0.5A 3.6A 15 V min. 3 V max. 0.5 ms max. 1.5 ms max. 0.25 mA max. Zener diode 24VDC/24VDC 1.5 ms max. 0.5A 3.6A 14 V min. 6 V max. 0.5 ms max. 1.5 ms max. 0.1 mA max. Zener diode 24VDC/24VDC 0.2 ms max. 0.5A 3.6A 15 V min. 3 V max. 0.5 ms max. 1.5 ms max. 0.1 mA max. Zener diode 24VDC/24VDC 1.5 ms max. 0.5A 1.2A 14 V min. 6 V max. 0.5 ms max. 1.5 ms max. 0.25 mA max. Zener diode 24VDC/24VDC 1.5 ms max. 0.5A 1.2A 14 V min. 6 V max. 0.5 ms max. 1.5 ms max. 0.1 mA max. Zener diode 24VDC/24VDC 1.5 ms max. 0.5A 2.4A 14 V min. 6 V max. 0.5 ms max. 1.5 ms max. 0.25 mA max. Zener diode 24VDC/24VDC 1.5 ms max. 0.5A 2.4A 14 V min. 6 V max. 0.5 ms max. 1.5 ms max. 0.1 mA max. Zener diode 24VDC/12/24VDC 10 ms max. 0.5A 4A 14 V min. 6 V max. 2 ms max. 2 ms max. 0.1 mA max. Zener diode 24VDC/12/24VDC 10 ms max. 0.5A 4A 14 V min. 6 V max. 2 ms max. 2 ms max. 0.1 mA max. Zener diode 24VDC/240VAC 10 ms max. 2A 8A 14 V min. 6 V max. 10 ms max. 12 ms max. — None One wire type / One wire type One wire type / One wire type One wire type / One wire type One wire type / One wire type One wire type / One wire type One wire type / One wire type One wire type / One wire type One wire type / One wire type Three wire type / Two wire type Three wire type / Two wire type Three wire type / Two wire type Three wire type / Two wire type One wire type / One wire type Two wire type/ Two wire type 16 pts 1 com 16 pts 1 com 16 pts 1 com 16 pts 1 com 32 pts 1 com 32 pts 1 com 32 pts 1 com 32 pts 1 com 8 pts 1 com 8 pts 1 com 16 pts 1 com 16 pts 1 com 8 pts 1 com 8 pts 1 com 50mA Two wire type/ Two wire type 8 pts 1 com 70mA 55mA 50mA 55mA 60mA 60mA 60mA 60mA 45mA 45mA 50mA 50mA 70mA 70mA +COM: Positive common (sink) -COM: Negative common (source) Mitsubishi Electric Automation | Distributed I/O 343 LED display LED Name Item Checked X0 1 2 3 4 5 6 7 PW Turns on when the power supply to the remote I/O module is turned on. L RUN Turns on when normal data is received from the master station, and turns off via timeout. XO to 1F Transmission speed setting switch B RATE 1 4 2 1 ON Setting value Transmission speed 0 156 kbps AJ65SBTB1-8D DA L ERR STATION NO. 40 20 10 8 4 2 DG DB Turns on in case of a transmission error (CRC error) and turns off via timeout (L RUN also turns off). It turns on if the settings for station number and transmission speed are wrong. (It turns off when the settings are modified and the power supply is turned off then on again.) It flashes if the station-number and transmission-speed settings are changed while the communication is active. (L RUN also turns on. The module operates under the conditions given via the station-number and transmissionspeed settings at the time the power supply was turned on.) +24V 24G X0 X2 (FG) SLD X4 X1 X6 X3 COM X5 X7 COM 625 kbps 2 2.5 Mbps 3 5.0 Mbps 4 10 Mbps Station number setting switches "10," "20," and "40" in STATION NO. are used for setting the second digit of the station number. "1," "2," "4," and "8" in STATION NO. are used for setting the first digit of the station number. Displays the on/off status of input. The LEDs turn on in the "On" state, and off in the "Off" state. DIN rail hook Terminal block Hook for mounting the module to the DIN rail Unit: mm External Dimensions AJ65SBTB1-16o AJ65SBTB3-8o AJ65SBTB2-8o AJ65SBTB2N-8o AJ65SBTB32-8o 40 40 AJ65SBTB1-8o 87.3 118 78.3mm +10 (mounting pitch) Two 4.5mm x 5.1mm mounting holes (for M4 mounting screws) PW L RUN L ERR X0 (FG) SLD X2 X4 X1 X6 X3 X5 DA COM X7 COM DG STATION NO. B RATE 40 20 10 8 4 2 1 4 2 1 A J65SBTB1-16D +24V DB 50 24G X8 9 A B C D E F ON MITSUBISHI 24G SLD X0 X2 (FG) X1 X4 X3 X6 X5 X8 X7 XA XC X9 XB XE XD COM XF COM X16 X18 4 4 50 DB +24V X0 1 2 3 4 5 6 7 16.5 16.5 B RATE 4 2 1 ON DG (mounting pitch) Two 4.5mm x 5.1mm mounting holes (for M4 mounting screws) 1 AJ65SBTB1-8D DA +1 0 109mm STATION NO. 40 20 10 8 4 2 X0 1 2 3 4 5 6 7 AJ65SBTB1-32o AJ65SBTB3-16o AJ65SBTB2-16o AJ65SBTB2N-16o AJ65SBTB32-16o 46 40 9.5 AJ65BTB1-16o 179 Two ø4.5mm mounting holes MITSUBISHI A J65BTB1-16D 170mm +10 (mounting pitch) Two 4.5mm x 5.1mm mounting holes (for M4 mounting screws) B RATE PW L RUN L ERR L RUN SD RD 2 3 L ERR. 3 DA +24V 4 DB 6 9 7 8 9 11 A B C 13 D E F 15 19 17 21 25 23 DB 50 5 DG X10 11 12 13 14 15 16 17 X18 19 1A 1B 1C 1D 1E 1F STATION NO. B RATE 40 20 10 8 4 2 1 4 2 1 A J65SBTB1-32D +24V 24G SLD X0 X2 (FG) X1 X4 X3 X6 X5 X8 X7 XA X9 XC XB XE XD X10 XF X12 X11 X14 X13 X15 X17 X1A X19 X1C X1B X1E X1D COM X1F COM 65 4 DA 56 3 7 5 DG 2 2 STATION NO. X10 X1 0 1 9 0 1 2 8 2 3 7 3 6 5 4 6 5 4 27 24G 6 8 10 12 14 16 18 20 22 24 26 SLD 89 4 1 1 X8 9 A B C D E F ON MITSUBISHI 4 0 X0 1 2 3 4 5 6 7 16.5 0 1 PW (FG) 142.9 151.9 Two ø4.5mm mounting holes AJ65BTB2-16o MITSUBISHI A J65BTB2-16D B RATE 0 1 PW L RUN SD RD 2 3 L ERR. 46 1 3 DA 5 4 DB 2 3 7 +24V DG 2 1 4 5 6 9 7 8 9 11 A B 13 C D E 15 F 17 19 21 23 25 27 56 9.5 STATION NO. X10 X1 0 1 9 0 1 2 8 2 3 7 3 6 5 4 6 5 4 29 31 33 35 37 24G 6 8 10 12 14 16 18 20 SLD (FG) 188.4 197.4 22 24 26 28 30 32 34 36 65 4 0 344 1 Sold by AA Electric 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com n DISTRIBUTED I/O Guide to Module Features External Connections Input Modules Sold by AA Electric 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com AJ65SBTB1-8D type Module power supply I/O power supply 1 2 3 4 5 6 7 DA DB DG SLD +24V FG 24G 8 9 10 11 12 13 14 15 16 17 X0 X1 X2 X3 X4 X5 X6 X7 COM COM AJ65SBTB1-16D type, AJ65SBTB1-16D1 type Isolation DC/DC Module power supply R R R R I/O power supply AJ65SBTB1-32D type • AJ65SBTB1-32D1 type Module power supply I/O power supply 1 2 3 4 5 6 7 DA DB DG SLD +24V FG 24G 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 X0 X1 X2 X3 X4 X5 X6 X7 X8 X9 XA XB XC XD XE XF X10 X11 X12 X13 X14 X15 X16 X17 X18 X19 X1A X1B X1C X1D X1E X1F COM COM 1 2 3 4 5 6 7 DA DB DG SLD +24V FG 24G 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 X0 X1 X2 X3 X4 X5 X6 X7 X8 X9 XA XB XC XD XE XF COM COM Isolation DC/DC R R R R AJ65SBTB2N-8A type 1 Isolation DC/DC R R Module power supply DA 2 DB 3 DG 4 SLD 5 +24V 6 FG 7 24G 8 X0 Isolation DC/DC R R 9 COM B R 10 X1 11 COM B 12 X2 13 COM B 14 X3 15 COM B 16 X4 17 COM B 18 X5 19 COM B 20 X6 21 COM B 22 X7 23 COM B 24 COM A R 25 COM B R AC100V AJ65SBTB2N-16A type AJ65SBTB3-8D type 1 2 3 4 5 6 7 DA DB DG SLD +24V FG 24G 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 X0 COM B X1 COM B X2 COM B X3 COM B X4 COM B X5 COM B X6 COM B X7 COM B X8 COM B X9 COM B XA COM B XB COM B XC COM B XD COM B XE COM B XF COM B COM A COM B 1 2 3 4 5 6 7 Isolation DC/DC Module power supply DA DB DG SLD +24V FG 24G Isolation DC/DC Module power supply R R R Three wire type sensor Two wire type sensor Source Sink 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 X0 COMA X1 COMB X2 COMA X3 COMB X4 COMA X5 COMB X6 COMA X7 COMB DC24A DC24B R R DC24V AC100V Mitsubishi Electric Automation | Distributed I/O 345 AJ65SBTB3-16D type AJ65BTB1-16D type Module power supply Three wire type sensor Two wire type sensor Source Sink DC24V 1 2 3 4 5 6 7 DA DB DG SLD +24V FG 24G 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 X0 COMA X1 COMB X2 COMA X3 COMB X4 COMA X5 COMB X6 COMA X7 COMB X8 COMA X9 COMB XA COMA XB COMB XC COMA XD COMB XE COMA XF COMB DC24A DC24B Isolation DC/DC R DC24V R DC24V 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 DA DB DG SLD +24V FG 24G X0 X1 X2 X3 X4 X5 X6 X7 COM NC X8 X9 XA XB XC XD XE XF COM NC DC/DC R R R R AJ65BTB2-16D type DC24V DC24V 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 Output Modules DA DB DG SLD +24V FG 24G NC NC X0 COMB X1 X2 COMB X3 X4 COMB X5 X6 COMB X7 NC NC X8 COMB X9 XA COMB XB XC COMB XD XE COMB XF COMA COMB AJ65SBTB1-8T type DC/DC R 1 2 3 4 5 6 7 DA DB DG SLD +24V FG 24G 8 9 10 11 12 13 14 15 16 17 Y0 Y1 Y2 Y3 Y4 Y5 Y6 Y7 CTL+ COM- Isolation DC/DC Module power supply R Constant voltage circuit L I/O power supply (external power supply) L Load power supply In case I/O power supply and load power supply are common R R L L 8 9 10 11 12 13 14 15 16 17 Y0 Y1 Y2 Y3 Y4 Y5 Y6 Y7 CTL+ COM- AJ65SBTB1-16T type AJ65SBTB1-8T1 type Module power supply 1 2 3 4 5 6 7 DA DB DG SLD +24V FG 24G 8 9 10 11 12 13 14 15 16 17 Y0 Y1 Y2 Y3 Y4 Y5 Y6 Y7 CTL+ COM- Module power supply L I/O power supply (external power supply) L Load power supply In case I/O power supply and load power supply are common L L 346 8 9 10 11 12 13 14 15 16 17 Y0 Y1 Y2 Y3 Y4 Y5 Y6 Y7 CTL+ COM- L Isolation DC/DC Constant voltage circuit L 1 2 3 4 5 6 7 DA DB DG SLD +24V FG 24G 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 Y0 Y1 Y2 Y3 Y4 Y5 Y6 Y7 Y8 Y9 YA YB YC YD YE YF CTL+ COM- I/O power supply (external power supply) Load power supply L 24 CTL+ 25 COM- Isolation DC/DC Constant voltage circuit In case I/O power supply and load power supply are common Sold by AA Electric 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com n DISTRIBUTED I/O External Connections External Connections AJ65SBTB1-32T type Sold by AA Electric 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com AJ65SBTB1-16T1 type Module power supply L L 1 2 3 4 5 6 7 DA DB DG SLD +24V FG 24G 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 Y0 Y1 Y2 Y3 Y4 Y5 Y6 Y7 Y8 Y9 YA YB YC YD YE YF CTL+ COM- I/O power supply (external power supply) Load power supply Isolation Module power supply DC/DC L Constant voltage circuit In case I/O power supply and load power supply are common L 24 CTL+ 25 COM- L I/O power supply (external power supply) 1 2 3 4 5 6 7 DA DB DG SLD +24V FG 24G 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 Y0 Y1 Y2 Y3 Y4 Y5 Y6 Y7 Y8 Y9 YA YB YC YD YE YF Y10 Y11 Y12 Y13 Y14 Y15 Y16 Y17 Y18 Y19 Y1A Y1B Y1C Y1D Y1E Y1F CTL+ COM- Isolation DC/DC Constant voltage circuit Load power supply L 40 CTL+ 41 COM- In case I/O power supply and load power supply are common AJ65SBTB1-32T1 type Module power supply L L I/O power supply (external power supply) Load power supply 1 2 3 4 5 6 7 DA DB DG SLD +24V FG 24G 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 Y0 Y1 Y2 Y3 Y4 Y5 Y6 Y7 Y8 Y9 YA YB YC YD YE YF Y10 Y11 Y12 Y13 Y14 Y15 Y16 Y17 Y18 Y19 Y1A Y1B Y1C Y1D Y1E Y1F CTL+ COM- L 40 CTL+ 41 COM- Isolation DC/DC AJ65SBTB1-8TE type Module power supply Load power supply Module power supply L L Load power supply I/O power supply (external power supply) DA DB DG SLD +24V FG 24G 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 Y0 Y1 Y2 Y3 Y4 Y5 Y6 Y7 Y8 Y9 YA YB YC YD YE YF COM+ CTL- DA DB DG SLD +24V FG 24G 8 9 10 11 12 13 14 15 16 17 Y0 Y1 Y2 Y3 Y4 Y5 Y6 Y7 COM+ CTL- Isolation DC/DC Constant voltage circuit L In case I/O power supply and load power supply are common 16 COM+ 17 CTLConstant voltage circuit In case I/O power supply and load power supply are common AJ65SBTB2-8T type Isolation DC/DC Module power supply L Constant voltage circuit In case I/O power supply and load power supply are common L L I/O power supply (external power supply) AJ65SBTB1-16TE type 1 2 3 4 5 6 7 L 1 2 3 4 5 6 7 1 2 3 4 5 6 7 DA DB DG SLD +24V FG 24G 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 Y0 COM Y1 COM Y2 COM Y3 COM Y4 COM Y5 COM Y6 COM Y7 COM DC24V DC24G Isolation DC/DC Constant voltage circuit I/O power supply (external power supply) 24 COM+ 25 CTL- Mitsubishi Electric Automation | Distributed I/O 347 n DISTRIBUTED I/O External Connections AJ65SBTB2-16T type AJ65SBTB2-8T1 type L I/O power supply (external power supply) DA DB DG SLD +24V FG 24G 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 Y0 COM Y1 COM Y2 COM Y3 COM Y4 COM Y5 COM Y6 COM Y7 COM DC24V DC24G Isolation L DC/DC Constant voltage circuit DA DB DG SLD +24V FG 24G 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 Y0 COM Y1 COM Y2 COM Y3 COM Y4 COM Y5 COM Y6 COM Y7 COM Y8 COM Y9 COM YA COM YB COM YC COM YD COM YE COM YF COM DC24V DC24G Isolation DC/DC Constant voltage circuit I/O power supply (external power supply) AJ65SBTB2-16T1 type Module power supply L 1 2 3 4 5 6 7 DA DB DG SLD +24V FG 24G 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 Y0 COM Y1 COM Y2 COM Y3 COM Y4 COM Y5 COM Y6 COM Y7 COM Y8 COM Y9 COM YA COM YB COM YC COM YD COM YE COM YF COM DC24V DC24G Isolation AJ65SBTB2N-8R type DC/DC 1 Module power supply L DA 2 DB 3 DG 4 SLD 5 +24V 6 FG 7 24G 8 Y0 Isolation DC/DC 9 COM B RA 10 Y1 11 COM B 12 Y2 13 COM B 14 Y3 15 COM B 16 Y4 17 COM B 18 Y5 19 COM B 20 Y6 21 COM B Constant voltage circuit L 22 Y7 23 COM B I/O power supply (external power supply) 24 COM A 25 COM B AC100/200V AJ65SBTB2N-8S type AJ65SBTB2N-16S type AJ65SBTB2N-16R type 1 2 3 4 5 6 7 DA DB DG SLD +24V FG 24G Isolation DC/DC Module power supply L L AC100/200V 348 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 Y0 COM B Y1 COM B Y2 COM B Y3 COM B Y4 COM B Y5 COM B Y6 COM B Y7 COM B Y8 COM B Y9 COM B YA COM B YB COM B YC COM B YD COM B YE COM B YF COM B COM A COM B 1 DA 2 DB 3 DG 4 SLD 5 +24V 6 FG 7 24G Module power supply Module power supply DC/DC L Surge suppression RA L Isolation 8 Y0 9 COM B 10 Y1 11 COM B R Triac 12 Y2 13 COM B 14 Y3 15 COM B 16 Y4 17 COM B 18 Y5 19 COM B 20 Y6 21 COM B L 22 Y7 23 COM B L 24 COM A 25 COM B AC100/200V AC100/200V 1 2 3 4 5 6 7 DA DB DG SLD +24V FG 24G 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 Y0 COM B Y1 COM B Y2 COM B Y3 COM B Y4 COM B Y5 COM B Y6 COM B Y7 COM B Y8 COM B Y9 COM B YA COM B YB COM B YC COM B YD COM B YE COM B YF COM B COM A COM B Isolation DC/DC Surge suppression R Triac Sold by AA Electric 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com Module power supply 1 2 3 4 5 6 7 Module power supply 1 2 3 4 5 6 7 External Connections AJ65BTB2-16T type Output Modules Sold by AA Electric 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com AJ65BTB1-16T type 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 DC24V L DC12/24V L DC12/24V DA DB DG SLD +24V FG 24G Y0 Y1 Y2 Y3 Y4 Y5 Y6 Y7 COM1+ CTL1Y8 Y9 YA YB YC YD YE YF COM2CTL2+ 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 DC24V DC/DC L R DC12/24V R L DC12/24V DA DB DG SLD +24V FG 24G NC NC Y0 COM1+ Y1 Y2 COM1+ Y3 Y4 COM1+ Y5 Y6 COM1+ Y7 COM1COM1+ Y8 COM2+ Y9 YA COM2+ YB YC COM2+ YD YE COM2+ YF COM2COM2+ DC/DC R R R R Combination Input/Output Modules AJ65BTB2-16R type DC24V DC24V L AC240V L AC240V 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 DA DB DG SLD +24V FG 24G CTLG CTL+ Y0 COMB Y1 Y2 COMB Y3 Y4 COMB Y5 Y6 COMB Y7 COMA COMB Y8 COMD Y9 YA COMD YB YC COMD YD YE COMD YF COMC COMD AJ65SBTB1-16DT, AJ65SBTB1-16DT1 type RA L RA I/O power supply (external power supply) 1 2 3 4 5 6 7 DA DB DG SLD +24V FG 24G 24 COM+ 25 COM- R R Constant voltage circuit 24 COM+ 25 COM- 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 X0 X1 X2 X3 X4 X5 X6 X7 Y8 Y9 YA YB YC YD YE YF 24 25 COM+ COM- In case I/O power supply and load power supply are common AJ65SBTB1-32DT, AJ65SBTB1-32DT1 type Isolation Module power supply DC/DC Load power supply L X0 X1 X2 X3 X4 X5 X6 X7 Y8 Y9 YA YB YC YD YE YF Isolation DC/DC Load power supply AJ65SBTB1-16DT2, AJ65SBTB1-16DT3 type I/O power supply (external power supply) 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 Module power supply 40 COM+ 41 COM- L DA DB DG SLD +24V FG 24G DC/DC L Module power supply 1 2 3 4 5 6 7 In case I/O power supply and load power supply are common R R L Constant voltage circuit I/O power supply (external power supply) 1 2 3 4 5 6 7 DA DB DG SLD +24V FG 24G 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 X0 X1 X2 X3 X4 X5 X6 X7 X8 X9 XA XB XC XD XE XF Y10 Y11 Y12 Y13 Y14 Y15 Y16 Y17 Y18 Y19 Y1A Y1B Y1C Y1D Y1E Y1F COM+ COM- Isolation DC/DC R R Constant voltage circuit Load power supply In case I/O power supply L and load power supply are common 40 COM+ 41 COM- Mitsubishi Electric Automation | Distributed I/O 349 AJ65SBTB1-32DT2, AJ65SBTB1-32DT3 type 1 2 3 4 5 6 7 Module power supply DA DB DG SLD +24V FG 24G X0 8 9 X1 10 X2 11 X3 12 X4 13 X5 14 X6 15 X7 16 X8 17 X9 18 XA 19 XB 20 XC 21 XD 22 XE 23 XF 24 Y10 25 Y11 26 Y12 27 Y13 28 Y14 29 Y15 30 Y16 31 Y17 32 Y18 33 Y19 34 Y1A 35 Y1B 36 Y1C 37 Y1D 38 Y1E 39 Y1F 40 COM+ 41 COM- L I/O power supply (external power supply) AJ65SBTB32-8DT type Isolation DC/DC 1 2 3 4 5 6 7 DA DB DG SLD +24V FG 24G 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 X0 COM+ X1 COMX2 COM+ X3 COMY8 COM+ Y9 COM+ YA COM+ YB COM+ DC24V DC24G R R Module power supply Three wire type sensor L Isolation DC/DC R R Constant voltage circuit I/O power supply (external power supply) Constant voltage circuit Load power supply L 40 COM+ 41 COM- In case I/O power supply and load power supply are common AJ65SBTB32-16DT type AJ65SBTB32-8DT2 type Module power supply Three wire type sensor L 1 2 3 4 5 6 7 DA DB DG SLD +24V FG 24G 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 X0 COM+ X1 COMX2 COM+ X3 COMY8 COM+ Y9 COM+ YA COM+ YB COM+ DC24V DC24G Module power supply Isolation DC/DC Three wire type sensor R R L Constant voltage circuit I/O power supply (external power supply) 1 2 3 4 5 6 7 DA DB DG SLD +24V FG 24G 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 X0 COM+ X1 COMX2 COM+ X3 COMX4 COM+ X5 COMX6 COM+ X7 COMY8 COM+ Y9 COM+ YA COM+ YB COM+ YC COM+ YD COM+ YE COM+ YF COM+ DC24V DC24G Isolation DC/DC R R Constant voltage circuit I/O power supply (external power supply) AJ65SBTB32-16DT2 type AJ65BTB1-16DT type 1 2 3 4 5 6 7 Module power supply 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 Three wire type sensor L DA DB DG SLD +24V FG 24G X0 COM+ X1 COMX2 COM+ X3 COMX4 COM+ X5 COMX6 COM+ X7 COMY8 COM+ Y9 COM+ YA COM+ YB COM+ YC COM+ YD COM+ YE COM+ YF COM+ DC24V DC24G Isolation DC/DC R R DC24V DC24V L DC12/24V Constant voltage circuit 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 DA DB DG SLD +24V FG 24G X0 X1 X2 X3 X4 X5 X6 X7 COM1+ NC Y8 Y9 YA YB YC YD YE YF COM2CTL2+ DC/DC R R R I/O power supply (external power supply) AJ65BTB2-16DT type DC24V DC24V L DC12/24V 350 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 DA DB DG SLD +24V FG 24G NC NC X0 COM1X1 X2 COM1X3 X4 COM1X5 X6 COM1X7 COM1+ COM1Y8 COM2+ Y9 YA COM2+ YB YC COM2+ YD YE COM2+ YF COM2COM2+ AJ65BTB2-16DR type DC24V DC/DC DC24V R R DC24V L R AC240V 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 DA DB DG SLD +24V FG 24G CTLG CTL+ X0 COMB X1 X2 COMB X3 X4 COMB X5 X6 COMB X7 COMA COMB Y8 COMD Y9 YA COMD YB YC COMD YD YE COMD YF COMC COMD DC/DC R R RA Sold by AA Electric 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com n DISTRIBUTED I/O External Connections Sold by AA Electric 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com CC-Link Remote I/O: AJ65SBTCo-o / AJ65VBTCUo-o One-Touch Connector Type n One touch connector offers labor and material cost savings; No stripping of cable or lugs required. n IDC type connection makes a reliable contact. n Connectors available separately. n All models UL • cUL listed and CE certified. • One Touch Connectors No need for soldering, wire stripping or screw tightening. Press in Wiring securely connected simply by pressing the side of the plug inward after inserting the wire into the connector. Connector For a detailed description of the connectors see introduction to this section. Performance Specifications Input Module Model Name Input Type Number of Input Points Isolation Method Rated Input Voltage ON Voltage OFF Voltage OFF—ON Common Connection ON—OFF External Connection Wire Type Input Response Time Operating Voltage Internal Current Consumption DC input +COM/–COM common type 32 points Photocoupler 24 VDC 14 V min. 6 V max. 1.5 ms max. 1.5 ms max. One wire type 32 pts 1 com 45mA AJ65SBTC1-32D1 DC input +COM/–COM common type 32 points Photocoupler 24 VDC 15 V min. 3 V max. 0.2 ms max. 0.2 ms max. One wire type 32 pts 1 com 45mA AJ65SBTC4-16D DC input +COM/–COM common type 16 points Photocoupler 24 VDC 14 V min. 6 V max. 1.5 ms max. 1.5 ms max. Four wire type 16 pts 1 com 35mA AJ65VBTCU3-8D1 DC input +COM type 8 points Photocoupler 24 VDC 15 V min. 3 V max. 0.2 ms max. 0.2 ms max. Three wire type 8 pts 1 com 35mA AJ65VBTCU3-16D1 DC input +COM type 16 points Photocoupler 24 VDC 15 V min. 3 V max. 0.2 ms max. 0.2 ms max. Three wire type 16 pts 1 com 40mA AJ65SBTC1-32D Output Module Model Name Output Type Number of Output Points Isolation Method Rated Load Voltage 1 Point 1 Common OFF—ON ON—OFF Leakage Current Max. Load Current Output Response Time External Surge Connection Suppression Wire Type Common Connection Internal Current Consumption AJ65SBTC1-32T Transistor output Sink type 32 points Photocoupler 12/24 VDC 0.1A 3.2A 0.5 ms max. 1.5 ms max. 0.25 mA max. Zener diode One wire type 32 points 1 common 60mA AJ65SBTC1-32T1 Transistor output Sink type 32 points Photocoupler 12/24 VDC 0.1A 3.2A 0.5 ms max. 1.5 ms max. 0.1 mA max. Zener diode One wire type 32 points 1 common 60mA AJ65VBTCU2-8T Transistor output Sink type 8 points Photocoupler 12/24 VDC 0.1A 0.8A 1 ms max. 1 ms max. 0.1 mA max. Zener diode Two wire type 8 points 1 common 35mA AJ65VBTCU2-16T Transistor output Sink type 16 points Photocoupler 12/24 VDC 0.1A 1.6A 1 ms max. 1 ms max. 0.1 mA max. Zener diode Two wire type 16 points 1 common 40mA Combined I/O Module Model Name I/O Type Number of I/O Points Isolation Method Rated Input/Load Voltage 24VDC/24VDC Operating Voltage ON Voltage OFF Voltage 1 1 Point Common 14 V min. 6 V max. 0.5A DC input / trans output +COM type / sink type 8 pts / 8 pts Photocoupler / photocoupler AJ65SBTC4-16DT2 DC input / trans output +COM type / sink type 8 pts / 8 pts Photocoupler / photocoupler 24VDC/24VDC 14 V min. 6 V max. AJ65SBTC1-32DT DC input / trans output +COM type / sink type 16 pts /16 pts Photocoupler / photocoupler 24VDC/24VDC 14 V min. AJ65SBTC1-32DT1 DC input / trans output +COM type / sink type 16 pts /16 pts Photocoupler / photocoupler 24VDC/24VDC AJ65SBTC1-32DT2 DC input / trans output +COM type / sink type 16 pts /16 pts Photocoupler / photocoupler 24VDC/24VDC AJ65SBTC1-32DT3 DC input / trans output +COM type / sink type 16 pts /16 pts Photocoupler / photocoupler AJ65SBTC4-16DT 24VDC/24VDC Maximum Load Current Output Input Response Time Leakage Response Current Time OFF–ON ON–OFF Zener diode Four wire type / Four wire type 16 points 1 common 40mA 0.1 mA max. Zener diode Four wire type / Four wire type 16 points 1 common 40mA 1.5 ms max. 0.25 mA max. Zener diode One wire type / One wire type 32 points 1 common 50mA 0.5 ms max. 1.5 ms max. 0.25 mA max. Zener diode One wire type / One wire type 32 points 1 common 50mA 1.5 ms max. 0.5 ms max. 1.5 ms max. 0.1 mA max. Zener diode One wire type / One wire type 32 points 1 common 50mA 0.2 ms max. 0.5 ms max. 1.5 ms max. 0.1 mA max. Zener diode One wire type / One wire type 32 points 1 common 50mA 2.4A 1.5 ms max. 0.5 ms max. 1.5 ms max. 0.25 mA max. 0.5A 2.4A 1.5 ms max. 0.5 ms max. 1.5 ms max. 6 V max. 0.1A 1.6A 1.5 ms max. 0.5 ms max. 15 V min. 3 V max. 0.1A 1.6A 0.2 ms max. 14 V min. 6 V max. 0.1A 1.6A 1.6A 15 V min. 3 V max. 0.1A External Internal Surge Connection Wire Common Current Suppression Type on Input/ Connection Consumption Output Sides +COM: Positive common (sink) -COM: Negative common (source) Mitsubishi Electric Automation | Distributed I/O 351 AJ65VBTCUo-16o AJ65VBTCUo-8o 2. Transmission speed setting switch Setting value 40 20 10 8 4 2 1 4 2 Transmission speed 0 156 kbps 1 625 kbps 2 2.5 Mbps 3 5.0 Mbps 4 10 Mbps 1 40 20 10 8 4 2 1 4 2 S T A T I O N N O B R A T E 1 1. Operation LED display S T A T I O N 3 LED name N O B 2 R A T E PW L RUN 3. Station number setting switches L ERR A J65VBTCU3-16D1 A J65VBTCU3-8D1 "10," "20," and "40" in STATION NO. are used for setting the second digit of the station number. "1," "2," "4," and "8" in STATION NO. are used for setting the first digit of the station number. CON A CON B L I N K CON A 4 X0 to 1F PW L RUN L RUN X1 X4 Connector pin no. 1 0 1 2 3 4 5 6 7 X3 Turns on in case of a transmission error (CRC error) and turns off via timeout (L RUN also turns off). It turns on if the settings for station number and transmission speed are wrong. It flashes if the station-number and transmission-speed settings are changed while the communication is active. Y0 to 1F Displays the on/off status of input/output. L ERR L ERR X2 4. One-touch connector for communication Turns on when normal data is received from the master station, and turns off via timeout. L I N K CON B PW X0 Item checked Turns on when the power supply to the remote I/O module is turned on. 0 1 2 3 4 5 6 7 6 X5 4321 8 9 A B C D E F X6 X7 X0∼X7 Pin no. 4 3 2 1 Name SLD NC V- / I- V+ / I+ P W / A U CON X D CON C X8∼XF 5. One-touch connector for power supply and FG Connector pin no. 54321 P W / A U CON X D CON C 5 6. Connector for input/output signals Pin no. 5 4 3 2 1 Name FGI AG 24V 24V FG AJ65SBTCo-16o Operation LED display X0 1 2 3 4 5 6 7 X8 9 A B C D E F STATION NO. 40 20 10 8 4 2 Transmission speed setting switch B RATE 1 4 2 1 Setting value ON AJ65SBTC4-16D DA DG DB +24V SLD 24G (FG) X0 X8 +24V 24G X1 X9 +24V 24G X2 XA +24V 24G X3 XB +24V 24G X4 XC +24V 24G X5 XD +24V 24G X6 XE +24V 24G X7 XF +24V 24G CTL+ COM- Transmission speed 0 156 kbps 1 625 kbps 2 2.5 Mbps 3 5.0 Mbps 4 10 Mbps Station number setting switches "10," "20," and "40" in STATION NO. are used for setting the second digit of the station number. "1," "2," "4," and "8" in STATION NO. are used for setting the first digit of the station number. Terminal block for communication DIN rail hook Connector for input/output signals AJ65SBTCo-32o Transmission speed setting switch Operation LED display LED name PW Item checked Turns on when the power supply to the digital I/O module is turned on. PW L RUN L ERR L RUN L ERR X0 to 1F X0 to F/ Y10 to 1F Y0 to 1F Turns on in case of a transmission error (CRC error) and turns off via timeout (L RUN also turns off). It turns on if the settings for station number and transmission speed are wrong. It flashes if the station-number and transmission-speed settings are changed while the communication is active. Displays the on/off status of input/output. X8 9 A B C D E F X10 11 12 13 14 15 16 17 X18 19 1A 1B 1C 1D 1E 1F DB DG +24V SLD A J65SBTC1-32D1 24G (FG) STATION NO. B RATE 40 20 10 8 4 2 1 4 2 1 X0-XF Setting value ON X10-X1F X0 X4 X8 XC X10 X14 X18 X1C X1 X5 X9 XD X11 X15 X19 X1D X2 X6 XA XE X12 X16 X1A X1E X3 X7 XB XF X13 X17 X1B X1F COM COM Terminal block for communication Transmission speed 0 156 kbps 1 625 kbps 2 2.5 Mbps 3 5.0 Mbps 4 10 Mbps Station number setting switches "10," "20," and "40" in STATION NO. are used for setting the second digit of the station number. "1," "2," "4," and "8" in STATION NO. are used for setting the first digit of the station number. Lit in ON state and unlit in OFF state. Connector for input/output signals 352 3 4 5 6 7 MITSUBISHI DA Turns on when normal data is received from the master station, and turns off via timeout. X0 1 2 DIN rail hook Sold by AA Electric 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com n DISTRIBUTED I/O Guide to Module Features External Dimensions 40 AJ65SBTC1-32o AJ65SBTC4-16o 118 109mm +10 (mounting pitch) Two 4.5mm x 5.1mm mounting holes (for M4 mounting screws) 16.5 PW L RUN L ERR 3 4 5 6 7 X8 9 A B C D E F X10 11 12 13 14 15 16 17 X0 1 2 X18 19 1A 1B 1C 1D 1E 1F MITSUBISHI DB DG +24V SLD ON 24G (FG) X10-X1F X0 X4 X8 XC X10 X14 X18 X1C X1 X5 X9 XD X11 X15 X19 X1D X2 X6 XA XE X12 X16 X1A X1E X3 X7 XB XF X13 X17 X1B X1F COM COM 4 50 DA STATION NO. B RATE 40 20 10 8 4 2 1 4 2 1 X0-XF A J65SBTC1-32D1 AJ65VBTCUo-8o AJ65VBTCUo-16o 31 41 62 31 60 62 16.5 16.5 A J65VBTCU3-8D1 A J65VBTCU3-16D1 CON A CON B X0 CON A L I N K CON B L I N K PW PW L RUN L RUN L ERR L ERR X1 X3 X4 0 1 2 3 4 5 6 7 0 1 2 3 4 5 6 7 115 X2 115 X5 X6 X7 X0~X7 CON C CON D X8~XF P W / A U X CON C CON D (Side view shows power and network connectors installed.) 8 9 A B C D E F P W / A U X (Side view shows power and network connectors installed.) External Connections Input Modules AJ65SBTC1-32D • S 56JA 1D23-1CTB AJ65SBTC4-16D type Sink input type 1 2 3 4 5 6 7 Module power supply DA DB DG SLD +24V FG 24G Isolation DC/DC DA DB DG SLD +24V FG 24G Isolation DC/DC Four wire type sensor (sink output) Detection circuit 1 2 3 4 5 6 7 Module power supply R Black (white) Orange (orange) Brown (red) Blue (black) R COM1 1 2 R 3 R 4 R R CON1 1 2 R 3 R 4 Three wire type sensor (sink output) Detection circuit Sold by AA Electric 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com Unit: mm Black (white) Orange (orange) Brown (red) Blue (black) COM2 1 R 2 R 3 4 R R CON2 1 2 Two wire type sensor (sink output) R 3 R 4 Detection circuit Black (white) Orange (orange) Brown (red) Blue (black) COM8 1 I/O power supply 4 3 Sink/source selector switch Sink 8 CTL+ 9 COM- R CON8 1 2 R 3 Source R R 2 R R 4 I/O power supply 8 COM 9 COM Mitsubishi Electric Automation | Distributed I/O 353 AJ65VBTCU3-8D1 type 1 2 3 4 5 LINK CABLE (IN) AJ65SBTC4-16D type Source input 1 2 3 4 5 6 7 Module power supply DA DB DG SLD +24V FG 24G Isolation Detection circuit Four wire type sensor (source output) R One-touch connector for communication R COM1 Black (white) Orange (orange) Brown (red) Blue (black) 1 2 1 2 3 4 5 UNIT POWER CABLE (IN) R 3 R 4 I/O POWER CABLE (IN) Three wire type sensor (source output) Detection circuit 1 2 3 4 5 LINK CABLE (OUT) DC/DC 1 R 2 R 3 1 2 3 4 5 UNIT POWER CABLE (OUT) I/O POWER CABLE (OUT) COM2 Black (white) Orange (orange) Brown (red) Blue (black) 4 CON.A DA DB DG NC SLD CON.B 1 DA 2 DB 3 DG 4 NC 5 SLD 1 2 3 4 5 Isolation CON.C 1 FG 2 +24V(UNIT) 3 24G(UNIT) 4 +24V(I/O) 5 24G(I/O) CON.D 1 FG 2 +24V(UNIT) 3 24G(UNIT) 4 +24V(I/O) 5 24G(I/O) DC/DC One-touch connector for power supply and FG Three wire type sensor (sink output) R 2 R 3 Two wire type sensor (sink output) Sink/source selector switch CON2 1 2 3 4 Detection circuit Sink 8 CTL+ 9 COM- (sink output) AJ65VBTCU3-16D1 type Out put M 1 2 3 4 5 LINK CABLE (IN) 1 2 3 4 5 LINK CABLE (OUT) One-touch connector for communication 1 2 3 4 5 UNIT POWER CABLE (IN) I/O POWER CABLE (IN) 1 2 3 4 5 UNIT POWER CABLE (OUT) I/O POWER CABLE (OUT) CON.A DA DB DG NC SLD CON.B 1 DA 2 DB 3 DG 4 NC 5 SLD 1 2 3 4 5 R R Source I/O power supply R 4 CON8 1 2 3 4 R R Detection circuit 1 R COM8 Black (white) Orange (orange) Brown (red) Blue (black) CON1 1 2 3 4 Detection circuit Two wire type sensor (sink output) odules AJ65SBTC1-32 type CON.C 1 FG 2 +24V(UNIT) 3 24G(UNIT) 4 +24V(I/O) 5 24G(I/O) CON.D 1 FG 2 +24V(UNIT) 3 24G(UNIT) 4 +24V(I/O) 5 24G(I/O) Isolation DC/DC DA DB DG SLD +24V FG 24G 1 2 3 4 5 6 7 Isolation DC/DC Module power supply 1 L CON1 2 3 4 L One-touch connector for power supply and FG Three wire type sensor (sink output) Two wire type sensor (sink output) R R Detection circuit CON1 1 2 3 4 CON8 CON2 1 2 3 4 R 1 L R Detection circuit 2 3 (sink output) 4 L CON16 1 2 3 4 R R I/O power supply (external power supply) Constant voltage circuit 8 CTL+ 9 COM- Load power supply In case I/O power supply and load power supply are common L 8 CTL+ 9 COM- S 56JA 1T23-1CTB AJ65VBTCU2-8 type type 1 2 3 4 5 6 7 DA DB DG SLD +24V FG 24G Module power supply L 1 L 4 Isolation 1 2 3 4 5 LINK CABLE (IN) DC/DC 1 2 3 4 5 LINK CABLE (OUT) CON1 2 One-touch connector for communication 3 1 2 3 4 5 UNIT POWER CABLE (IN) I/O POWER CABLE (IN) CON8 L 1 2 I/O power supply (external power supply) 8 CTL+ 9 COM- Constant voltage circuit L Load power supply In case I/O power supply and load power supply are common L 8 CTL+ 9 COM- Isolation DC/DC Constant voltage circuit 4 L 354 CON.C 1 FG 2 +24V(UNIT) 3 24G(UNIT) 4 +24V(I/O) 5 24G(I/O) CON.D 1 FG 2 +24V(UNIT) 3 24G(UNIT) 4 +24V(I/O) 5 24G(I/O) One-touch connector for power supply and FG 3 L 1 2 3 4 5 UNIT POWER CABLE (OUT) I/O POWER CABLE (OUT) CON.A DA DB DG NC SLD CON.B 1 DA 2 DB 3 DG 4 NC 5 SLD 1 2 3 4 5 L CON1 1 2 3 4 CON2 1 2 3 4 CON8 1 2 3 4 Sold by AA Electric 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com n DISTRIBUTED I/O External Connections External Connections AJ65VBTCU2-16T type 1 2 3 4 5 LINK CABLE (IN) 1 2 3 4 5 LINK CABLE (OUT) One-touch connector for communication 1 2 3 4 5 UNIT POWER CABLE (IN) I/O POWER CABLE (IN) 1 2 3 4 5 UNIT POWER CABLE (OUT) I/O POWER CABLE (OUT) AJ65SBTC1-32DT • AJ65SBTC1-32DT1 type DA DB DG SLD +24V FG 24G 1 2 3 4 5 6 7 CON.C 1 FG 2 +24V(UNIT) 3 24G(UNIT) 4 +24V(I/O) 5 24G(I/O) CON.D 1 FG 2 +24V(UNIT) 3 24G(UNIT) 4 +24V(I/O) 5 24G(I/O) Isolation DC/DC Module power supply Isolation CON1∼CON4 1 DC/DC R 2 R 3 4 R R One-touch connector for power supply and FG CON5∼CON8 Constant voltage circuit 1 L 2 CON1 1 2 3 4 L 3 4 L CON2 1 2 3 4 L I/O power supply (external power supply) Constant voltage circuit 8 COM+ 9 COM- Load power supply CON16 1 2 3 4 L In case I/O power supply and load power supply are common L 8 COM+ 9 COM- AJ65SBTC1-32DT2 • AJ65SBTC1-32DT3 type AJ65SBTC4-16DT type Example of Connection with 4-, 3-, and 2-wire type Sensors DA DB DG SLD +24V FG 24G 1 2 3 4 5 6 7 Isolation DC/DC Module power supply 1 2 3 4 5 6 7 CON1∼CON4 1 R 2 Module power supply R 3 4 Four wire type sensor (sink output/sink input) R Detection circuit R DA DB DG SLD +24V FG 24G Isolation DC/DC R R COM1 Black (white) Orange (orange) Brown (red) Blue (black) 1 2 3 4 CON5∼CON8 1 L Three wire type sensor (source output) 3 4 L R R COM2 Detection circuit 2 1 2 3 4 I/O power supply (external power supply) Two wire type sensor (sink output) R R COM3 Detection circuit Constant voltage circuit 8 COM+ 9 COM- 1 2 3 4 In case I/O power supply and load power supply are common L 8 CTL+ 9 COM- 8 COM+ 9 COM- DC24V AJ65SBTC4-16DT2 type Example of Connection with 4-, 3-, and 2-wire type Sensors 1 2 3 4 5 6 7 Module power supply Detection circuit Four wire type sensor (sink output/sink input) Constant voltage circuit Load power supply DA DB DG SLD +24V FG 24G Other Example of Connection 1 2 3 4 5 6 7 Isolation DC/DC Module power supply DA DB DG SLD +24V FG 24G Isolation DC/DC R R COM1 Black (white) Orange (orange) Brown (red) Blue (black) 1 (sink input) 2 3 R R COM1 1 4 2 3 4 Three wire type sensor (source output) R R Detection circuit COM2 1 2 3 4 R Two wire type sensor (sink output) (sink output) L R R COM3 Detection circuit R COM3 1 2 3 4 1 2 3 8 CTL+ 9 COM8 CTL+ 9 COM- DC24V Constant voltage circuit 4 Constant voltage circuit Sold by AA Electric 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com Combination Input/Output Modules CON.A 1 DA 2 DB 3 DG 4 NC 5 SLD CON.B 1 DA 2 DB 3 DG 4 NC 5 SLD DC24V Mitsubishi Electric Automation | Distributed I/O 355 n Intended for OEM System Designers needing to embed a CC-Link network connection in their own products. n Each device offers differing amounts of discrete I/O to interface to the OEM device. n PCB mounted device. n All modules UL • cUL listed and CE certified. Performance Specifications Input Adapter Item AJ65MBTL1N-16D I/O Combination Adapter AJ65MBTL1N-16T AJ65MBTL1N-32T AJ65MBTL1N-16DT DC input DC input Transistor output Transistor output DC input / Transistor output +COM type +COM type Sink type Sink type +COM type / Sink type 16 points 32 points 16 points 32 points 8 points / 8 points Photocoupler Photocoupler Photocoupler Photocoupler Photocoupler / Photocoupler Input/Output Type Number Of Input/ Output Points Isolation Method Output Adapter AJ65MBTL1N-32D Rated Input/ Load Voltage 24 VDC 24 VDC 12/24 VDC 12/24 VDC 24 VDC / 24 VDC Maximum Load Current 1 Point — — 0.1A 0.1A 0.1A 1 Common — — 1.6A 3.2A 0.8A Operating Voltage ON Voltage 18 V min. 18 V min. — — 14 V min. / — Response Time OFF Voltage 6 V max. 6 V max. — — 6 V max. / — OFF—ON 1.5 ms max. 1.5 ms max. 1.0 ms max. 1.0 ms max. 1.5 ms max. / 1.0 ms max. ON—OFF 1.5 ms max. / 1.0 ms max. 1.5 ms max. 1.5 ms max. 1.0 ms max. 1.0 ms max. Leakage Current — — 0.1mA 0.1mA ±0.1mA Surge Suppression — — Zener diode Zener diode — / Zener diode External Connection Wire Type 44 pins (2 rows) 62 pins (2 rows) 44 pins (2 rows) 62 pins (2 rows) 44 pins (2 rows) Common Connection 16 points 1common 32 points 1common 16 points 1 common 32 points 1 common 16 points 1 common Current Consumption 35mA 45mA 50mA 60mA 50mA * +COM: Positive common (sink) Cascade Connection Method AJ65MBTL1N-16D AJ65MBTL1N-16T AJ65MBTL1N-16DT OE-IN AJ65MBTL1N-32D AJ65MBTL1N-32T OE-IN A20 OE-IN A20 OE-IN A29 B20 OE-OUT B20 OE-OUT B29 B22 DA B22 DA B31 A29 OE-OUT DA B29 OE-OUT B31 DA DA DA CC-Link Embedded I/O Adapters (2) SD-IN A19 A22 DB B21 DG A19 CC-Link Embedded I/O Adapters (1) A22 DB B21 DG FG RD A21 B18 A18 A17 RDGON GND B19 SLD B19 SD-OUT A18 RDGON A17 GND SD-IN SD-OUT RD DB B30 DG SD-IN A30 FG RD CC-Link Embedded I/O Adapters (1) A31 DB A28 B30 DG B27 A30 FG DB DG SLD B27 A27 FG A31 A28 FG B18 OPEN CC-Link Embedded I/O Adapters (2) DB DG A21 RD SD-IN RDGON A26 GND B28 SD-OUT A27 RDGON A26 B28 SD-OUT GND (OPEN) Reserve at least 5mm between I/O modules. 356 FG Sold by AA Electric 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com n DISTRIBUTED I/O CC-Link Remote I/O: AJ65MBTL1N-o Embedded I/O Adapters AJ65MBTL1N-o LED display LED name Transmission speed setting switch Item checked PW Lit when the embedded I/O module of CC-Link is turned on. L RUN Checks if the embedded I/O module of CC-Link communicates correctly with the master station. The lamp lights up upon reception of correct data from the master station, or it is unlit upon time-out. Setting value A J65MBTL1N-16DT PW XO~XF / XO~X1F YO~YF / YO~Y1F L RUN L ERR. ON Lit: Communication data error (CRC error), out-ofrange setting at station number setting or data link transmission speed setting switch Blink at certain intervals: Modification of station number setting or transmission speed setting switch setting in power-on state Blink at irregular intervals: Missing terminator, noise effect on embedded I/O module or special cable of CC-Link L ERR X0 X1 X2 X3 X4 X5 X6 X7 Y8 Y9 YA YB YC YD YE YF Transmission speed 0 156kbps 1 625kbps 2 2.5Mbps 3 5.0Mbps 4 10Mbps INPUT / OUTPUT UNIT 402010 8 4 2 1 4 2 1 STATION NO. B RATE DATE JAPAN Station number setting switches "10," "20," and "40" in STATION NO. are used for setting the second digit of the station number. "1," "2," "4," and "8" in STATION NO. are used for setting the first digit of the station number. The ON/OFF state of the input/output is displayed. Lit in ON state and unlit in OFF state. External Dimensions AJ65MBTL1N-16DT AJ65MBTL1N-16T AJ65MBTL1N-16D Unit: mm AJ65MBTL1N-32D AJ65MBTL1N-32T A J65MBTL1N-16DT L ERR. X0 X1 X2 X3 X4 X5 X6 X7 D=22 L RUN D=22 PW Y8 Y9 YA YB YC YD YE YF ON INPUT / OUTPUT UNIT 402010 8 4 2 1 4 2 1 STATION NO. B RATE DATE JAPAN W=85 H=31.5 W=53 3.5 3.5 H=31.5 A22 19.5 ø0.95±0.04 A31 A01 A01 B31 B22 B01 B01 Recommended circuit board dimensions top view 60±0.1 2±0.05 2±0.05 42±0.1 2±0.05 7.5 5.5 5.5 ø0.95±0.04 7.5 5.5 2±0.05 Sold by AA Electric 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com Adapter Features Recommended circuit board dimensions top view Mitsubishi Electric Automation | Distributed I/O 357 Input Module AJ65MBTL1N-16D AJ65MBTL1N-32D Pin No. Signal name Circuit board Pin No. Signal name DA B22 DA DB A22 DB DG B21 SLD A21 FG B20 OE-OUT A20 OE-IN B19 SD-OUT A19 2 B31 A31 DB B30 DG A30 FG B29 OE-OUT SD-IN OE-IN B28 SD-OUT A28 SD-IN B27 RD A27 RDGON B26 Vacant B18 RD A18 RDGON A26 GND B17 Vacant B25 Vacant 3 GND Vacant Vacant B15 Vacant X0 B23 A15 Vacant X1 A23 X0 B14 X0 X2 B22 X2 X1 A14 X1 X3 A22 X3 X2 B13 X2 X4 B21 X4 X3 A13 X3 X5 A21 X5 X4 B12 X4 X6 B20 X6 X5 A12 X5 X7 A20 X8 B19 X6 B11 X6 X9 A19 X9 X7 A11 X7 XA B18 XA X8 B10 X8 XB A18 XB X9 A10 X9 XC B17 XC XA B09 XA XD A17 A25 R R Vacant A24 Vacant X0 X8 XD A09 XB XE B16 B08 XC XF A16 XF A08 XD B15 X10 XE B07 X10 X11 A15 X11 XF A07 XF COM B06 COM X12 X13 B14 A14 X12 X13 A06 COM X14 B13 X14 B05 Vacant X15 A13 X15 A05 Vacant X16 B12 X16 B04 X17 A12 Vacant X18 B11 A04 Vacant X19 A11 X19 B03 Vacant X1A B10 X1A A03 Vacant X1B A10 X1B B02 +24V X1C B09 X1C A02 +24V X1D A09 X1D B01 24G X1E B08 X1E A01 24G X1F A08 X1F COM B07 COM A07 COM B06 Vacant A06 Vacant B05 Vacant A05 Vacant B04 Vacant A04 Vacant B03 Vacant A03 Vacant B02 +24V A02 +24V B01 24G A01 24G 22000pF 630V +24V 1 Isolation DC/DC Output Module Module power supply AJ65MBTL1N-16T 22000pF 630V +24V Signal name Circuit board Pin No. Signal name DA B22 DA DB A22 DB DG B21 DG SLD A21 FG B20 OE-OUT 1 24G AJ65MBTL1N-16T R X7 XB XE R X1 XD R Internal circuit Vacant B24 XC DC24V XE X17 X18 R R COM Isolation DC/DC FG リンク IC Internal circuit Output Module Combination Input / Output Module AJ65MBTL1N-32T AJ65MBTL1N-16DT A20 OE-IN B19 SD-OUT A19 SD-IN B18 RD A18 RDGON B17 Vacant A17 GND B16 Vacant A16 Vacant B15 Vacant A15 Vacant Y0 B14 Y0 Y1 A14 Y1 Y2 B13 Y2 Y3 A13 Y3 A29 OE-IN Y4 B12 Y4 B28 SD-OUT A20 OE-IN Y5 A12 Y5 A28 SD-IN B19 SD-OUT Y6 B11 Y6 B27 RD A19 SD-IN Y7 A11 A27 RDGON Y8 B10 B26 Vacant Y9 A10 Y9 A26 GND YA B09 YA B25 Vacant A25 B24 Vacant Vacant 2 L DC24V A29 A16 FG L DA SLD Internal circuit R AJ65MBTL1N-32D Pin No. Signal name DB B16 24G Signal name Circuit board Pin No. YB A09 YB B08 YC A08 YD YE B07 YE AJ65MBTL1N-32T Signal name DA B22 DG DB A22 DB A30 FG DG B21 DG B29 OE-OUT SLD A21 FG B20 OE-OUT SLD DA Internal circuit B18 RD A18 RDGON B17 Vacant A17 GND B16 Vacant A16 Vacant B15 Vacant A15 Vacant X0 B14 X0 X1 A14 X1 2 A24 Vacant B23 Y0 Y1 A23 Y1 Y2 B22 Y2 Y3 A22 Y3 Y4 B21 Y4 X2 B13 X2 Y5 A21 Y5 X3 A13 X3 Y6 B20 Y6 X4 B12 X4 Y7 A20 X5 A12 X5 Y8 B19 X6 B11 X6 X7 A11 X7 Y8 B10 Y8 A07 YF CTL+ B06 CTL+ COM- A06 CTL+ B05 COM- A05 COM- B04 Vacant A04 Vacant B03 Vacant A03 Vacant B02 +24V A02 +24V B01 24G YD A17 YD A01 24G YE B16 YE YF A16 YF Y10 B15 Y11 A15 Y12 Y13 B14 Y12 A14 Y13 Y14 B13 Y14 DC24G Y15 A13 Y16 B12 Y17 A12 Y18 B11 +24V 24G FG 1 DC/DC *1: Add according to environmental noise when necessary. Not supplied. *2: Connect A17 and A18 if cascade connection is not made. *3: Connect A26 and A27 if cascade connection is not made. DC12/24V Module power supply L Y7 Y8 Y9 A19 Y9 YA B18 YA YB A18 YB YC B17 YC YB B08 YC A07 YF B06 DC24V A06 DC24V Y15 B05 DC24G Y16 A05 DC24G B04 Vacant A04 Vacant B03 Vacant A03 Vacant B02 +24V A02 +24V B01 24G A01 24G Y17 Y18 Y19 Y1B A10 Y1B Y1C B09 Y1C Y1D A09 Y1D Y1E B08 Module power supply +24V 24G Y1E Y1F A08 Y1F CTL+ B07 CTL+ CTL+ A07 CTL+ COM- B06 COM- COM- A06 COM- B05 COM- A05 COM- B04 Vacant A04 Vacant B03 Vacant A03 B02 Vacant +24V A02 +24V B0 1 24G A0 1 24G 22000pF 630V 1 FG Constant voltage circuit COMCOM- Isolation DC/DC Internal circuit R R R R Y9 B07 L DC24V リンク IC YA A08 Y1A FG A09 YF B10 1 B09 YE A11 24G A10 YB YD Y19 +24V Y9 YA YC DC24V Y10 Y11 Y1A 22000pF 630V L AJ65MBTL1N-16DT DA Y0 L Isolation Signal name DB B30 YF 22000pF 630V Pin No. A31 3 Constant voltage circuit Circuit board B31 DB Y8 YD Signal name DA DG Y7 YC Module power supply 358 Circuit board DA DG A17 DC24V Module power supply DG AJ65MBTL1N-16D リンク IC YD YE Constant voltage circuit Isolation DC/DC Sold by AA Electric 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com n DISTRIBUTED I/O External Connections Sold by AA Electric 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com CC-Link Remote I/O: AJ65FBTAo-16o• AJ65SBTW4-16o Water Resistant Connector Type n Water resistant I/O power and network connections certified to IP67. n “F Type” modules can be replaced without disrupting the network. n Standard M12 connections. n F Type modules offer built-in terminating resistors, 55°C operating temperature. n W Type modules offer waterproof screw terminal connections for power and network connections. n Connectors available from a variety of third party sources. n All models UL • cUL listed and CE certified. Dustproof and waterproof connection caps are available to protect unused connectors. See the introduction to this section. AJ65SBTW4-16o Performance Specifications AJ65FBTA42-16o Input Module Model Name I/O Module Model Name Output Module Model Name Item Input/Output Type Number of Input/ Output Points Isolation Method Rated Input/ Load Voltage AJ65FBTA4-16D AJ65FBTA4-16DE AJ65SBTW4-16D AJ65FBTA2-16T AJ65FBTA2-16TE AJ65FBTA42-16DT AJ65FBTA42-16DTE AJ65SBTW4-16DT DC input DC input DC input Transistor output Transistor output DC input / transistor output DC input / transistor output DC input / transistor output +COM: Positive common (Sink) –COM: Negative common (Source) +COM: Positive common(Sink) –COM: Negative common(Source) common type Sink type Source type +COM: Positive common (Sink) / sink type –COM: Negative common (Source) / source type +COM: Positive common (Sink) / sink type 16 points 16 points 16 points 16 points 16 points Photocoupler Photocoupler Photocoupler Photocoupler Photocoupler 8 points/8 points Photocoupler /photocoupler 8 points/8 points Photocoupler /photocoupler 8 points/8 points Photocoupler /photocoupler 24 VDC 24 VDC 24 VDC 12/24VDC 12/24VDC 24 VDC/24 VDC 24 VDC/24 VDC 24 VDC/24 VDC Maximum 1 Point Load 1 Common Current — — — 0.5A 1.0A 0.5A 1.0A 0.5A — — — 4.0A 4.0A 2.4A 4.0A 2.4A Operating ON Voltage Voltage OFF Voltage 14 V min. 14 V min. 14 V min. — — 14 V min. 14 V min. 14 V min. 6 V max. 6 V max. 6 V max. — — 6 V max. 6 V max. 6 V max. 1.5 ms max. 1.5 ms max. 1.5 ms max. 0.5 ms max. 0.5 ms max. 1.5 ms/0.5 ms max. 1.5 ms/0.5 ms max. 1.5 ms/0.5 ms max. 1.5 ms max. 1.5 ms max. 1.5 ms max. 1.5 ms max. 1.5 ms max. 1.5 ms/1.5ms max. 1.5 ms/1.5 ms max. 1.5 ms/0.5 ms max. Surge Suppression — — — Zener diode Zener diode Zener diode Zener diode Zener diode External Connection Wire Type Four wire type Four wire type Four wire type Two wire type Two wire type Four wire type / two wire type Four wire type / two wire type Four wire type / two wire type 16 points 1 common 16 points 1 common 16 points 1 common 16 points 1 common 16 points 1 common 8 points 1 common /8 points 1 common 8 points 1 common /8 points 1 common 8 points 1 common /8 points 1 common 40mA 40mA 35mA 50mA 50mA 50mA 45mA — Fitting cable size ø4.0mm to 8.0mm / - OFF—ON Response Time ON—OFF Common Connection Current Consumption Cable Diameter Range For Water Resistant Compression Fitting — 40mA Fitting cable size — — — — Mitsubishi Electric Automation ø4.0mm to 8.0mm / - | Distributed I/O 359 AJ65FBTAo-16o Main body connector Terminal resistor setting Station number setting switches Dip switch 1 Dip switch 2 Description OFF ON OFF ON OFF OFF ON ON No terminal resistor 110 terminal On 130 terminal On Setting prohibited "10," "20," and "40" in STATION NO. are used for setting the second digit of the station number. "1," "2," "4," and "8" in STATION NO. are used for setting the first digit of the station number. TERMINATION 110Ω 130Ω ON Communication adapter (back side) Communication adapter (front side) Communication adapter connector Transmission speed setting switch Setting value 0 1 2 3 4 Waterproof connector for transmission line ON 40 20 10 8 4 2 1 4 2 1 STATION NO Communication adapter B RATE Transmission speed 156 kbps 625 kbps 2.5 Mbps 5.0 Mbps 10 Mbps A J65FBTA42-16DTE FG metal fittings Operating condition LED display PROTECT Y8 Y9 YA YB YC YD YE YF Description POWER On: Power supply is turned on. L RUN On: Communication is normal. L ERR. Off: Communication is normal. Off: Normal PROTECT On: Protection function is enabled. Y Y Waterproof connector for power-supply line Y Y Y Y Y Y Waterproof connector for input/output *All switches are mounted internally to maintain water resistance. AJ65SBTW4-16o Terminal block Transmission speed setting switch Setting value 0 1 2 3 4 Sink/source selector switch (only for AJ65SBTW4-16D) SINK Transmission speed 156 kbps 625 kbps 2.5 Mbps 5.0 Mbps 10 Mbps Station number setting switches SOURCE Switch the +COM, –COM type to either sink or source type. "10," "20," and "40" in STATION NO. are used for setting the second digit of the station number. "1," "2," "4," and "8" in STATION NO. are used for setting the first digit of the station number. Module top-cover mounting screw Operation LED display Waterproof connector for input/output line LINK CABL Module front-cover mounting screw LINK CABL LED name IN OUT POWER CABL L RUN L ERR. Y8 Y9 YA YB YC YD YE YF PW POWER CABL CON1 CON3 CON5 CON7 CON2 CON4 CON6 CON8 X0 X1 X2 X3 X4 X5 X6 X7 PW L RUN L ERR Turns on in case of a transmission error (CRC error) and turns off via timeout (L RUN also turns off). It turns on if the settings for station number and transmission speed are wrong. It turns on if the stationnumber and transmission-speed settings are changed while the communication is active. X0 to 1F Y0 to 1F Displays the on/off status of input. The LEDs turn on in the "On" state, and off in the "Off" state. STATION NO. AJ65SBTW4-16DT FG metal fittings Water resistant compression fitting for transmission/module power supply line. 360 Item checked Turns on when the power supply to the remote I/O module is turned on. Turns on when normal data is received from the master station, and turns off via timeout. *All switches and terminal blocks are mounted internally to maintain water resistance. Sold by AA Electric 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com n DISTRIBUTED I/O Module Features External Dimensions AJ65FBTA4-16D • AJ65FBTA4-16DE AJ65FBTA2-16T • AJ65FBTA2-16TE AJ65FBTA42-16DT • AJ65FBTA42-16DTE Two 4.5mm x 6mm oblong holes for M4 mounting screws AJ65SBTW4-16D • AJ65SBTW4-16DT +1 48 50±1 34±0.5 26.5 4.3 18.3 184. 7 180 6 (2.6) 21.3 2.1 192±1 +1 24 33 180 2.1 25 Two 4.5mm x 5.1mm mounting holes (for M4 mounting screws) LINK CABL IN POWER CABL LINK CABL OUT POWER CABL (2.6) PW CON1 CON3 CON5 CON7 CON2 CON4 CON6 CON8 L RUN L ERR. Y8 Y9 YA YB YC YD YE YF X0 X1 X2 X3 X4 X5 X6 X7 25 STATION NO. AJ65SBTW4-16DT Terminal Label 6 4.1 21.7 M4 mounting screw 32 35 External Connections Input Module AJ65FBTA4-16DE AJ65FBTA4-16D LINK OUT UNIT POWER Module mounting screw (FG) AUX. Detection circuit I/O connector Four wire type sensor (sink output) LINK IN 4 2 3 1 4 2 3 1 5 Communication circuit 110Ω R R 1 30Ω LINK OUT Terminal resistor setting switch UNIT POWER 1 3 5 2 4 DC/DC Module mounting screw (FG) AUX. 1 3 5 2 4 I/O connector Four wire type sensor (sink output) 4 2 1 3 5 R R R Three wire type sensor (sink output) Detection circuit Detection circuit LINK IN 4 2 3 1 5 1 3 5 2 4 Communication circuit 110Ω R R 130Ω Terminal resistor setting switch DC/DC 1 3 5 2 4 4 2 1 3 5 R R R Three wire type sensor (sink output) R 4 2 1 3 5 4 2 3 1 R 4 2 1 3 5 R R R R R R R R Two wire type sensor (sink output) Detection circuit 200 0 12 30 68 60 Two 4.5mm x 5.1mm mounting holes (for M4 mounting screws) 25 Sold by AA Electric 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com 60 0 Two wire type sensor (sink output) 4 2 1 3 5 4 2 1 3 5 R R R R R R R Pin no. 1 2 3 4 5 Pin no. 1 2 3 4 5 Pin no. X0 — X1 X2 — X3 X4 — X5 X6 — X7 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 Communication connector LINK IN SLD DB DG DA No pin Power supply connector UNIT POWER +24V (UNIT) Vacant 24G (UNIT) Vacant FG I/O connector Pin no. Pin no. +24V X1 X8 — 24G X9 X0 Vacant +24V X3 XA — 24G XB X2 Vacant +24V X5 24G X4 Vacant +24V X7 24G X6 Vacant XC — XD XE — XF R Pin layout LINK OUT SLD DB DG DA Vacant AUX. +24V (I/O) Vacant 24G (I/O) Vacant FG 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 Pin no. +24V X9 24G X8 Vacant +24V XB 24G XA Vacant +24V XD 24G XC Vacant +24V XF 24G XE Vacant LINK IN Male 2 3 1 4 LINK OUT Female 2 1 4 53 Pin no. 1 2 3 4 5 Pin no. 1 2 3 4 5 Pin no. UNIT POWER/AUX. Male X0 — X1 1 2 3 54 X2 — X3 I/O connector Female 2 1 4 53 Front view X4 — X5 X6 — X7 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 Communication connector LINK IN SLD DB DG DA No pin Power supply connector UNIT POWER +24V (UNIT) Vacant 24G (UNIT) Vacant FG I/O connector Pin no. Pin no. +24V X1 X8 — 24G X9 X0 Vacant +24V X3 XA — 24G XB X2 Vacant +24V X5 24G X4 Vacant +24V X7 24G X6 Vacant XC — XD XE — XF LINK OUT SLD DB DG DA Vacant AUX. +24V (I/O) Vacant 24G (I/O) Vacant FG 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 Pin no. +24V X9 24G X8 Vacant +24V XB 24G XA Vacant +24V XD 24G XC Vacant +24V XF 24G XE Vacant Mitsubishi Electric Automation | Distributed I/O 361 Output Modules AJ65FBTA2-16T AJ65FBTA2-16TE Pin no. 1 2 3 4 5 Pin no. LINK IN Communication circuit LINK OUT SLD SLD DB DB DG DG DA DA No pin Vacant Power supply connector UNIT POWER 1 2 3 4 5 Pin no. Pin no. Communication circuit AUX. +24V (UNIT) +24V (I/O) Vacant Vacant 24G (UNIT) 24G (I/O) Vacant Vacant FG FG I/O connector Pin Signal Pin Signal no. name no. name 1 +24V 1 +24V 2 Y1 2 Y9 Y0 Y8 — 3 Vacant — 3 Vacant Y1 Y9 4 Y0 4 Y8 5 Vacant 5 Vacant 1 +24V 1 +24V 2 Y3 2 YB Y2 YA — 3 Vacant — 3 Vacant Y3 YB 4 Y2 4 YA 5 Vacant 5 Vacant 1 +24V 1 +24V 2 Y5 2 YD Y4 YC — 3 Vacant — 3 Vacant Y5 YD 4 Y4 4 YC 5 Vacant 5 Vacant 1 +24V 1 +24V 2 Y7 2 YF Y6 YE — 3 Vacant — 3 Vacant Y7 YF 4 Y6 4 YE 5 Vacant 5 Vacant LINK OUT UNIT POWER Module mounting screw (FG) AUX. I/O connector Load L L Load L L Load L L 362 4 2 3 1 4 2 3 1 5 1 3 5 2 4 1 3 5 2 4 110Ω R R 130Ω Terminal resistor selector switch DC/DC Constant voltage circuit LINK IN LINK OUT 110Ω 4 2 3 1 5 R R 130Ω Terminal resistor selector switch UNIT POWER Module mounting screw (FG) AUX. 1 3 5 2 4 1 3 5 2 4 I/O connector 4 2 1 3 5 Load L L 4 2 1 3 5 Load L L 4 2 1 3 5 4 2 3 1 Load L L 4 2 1 3 5 4 2 1 3 5 4 2 1 3 5 DC/DC Constant voltage circuit LINK OUT SLD SLD DB DB DG DG DA DA No pin Vacant Power supply connector UNIT POWER AUX. +24V (UNIT) +24V (I/O) Vacant Vacant 24G (UNIT) 24G (I/O) Vacant Vacant FG FG I/O connector Pin Signal Pin Signal no. name no. name 1 Vacant 1 Vacant 2 Y1 2 Y9 Y0 Y8 — 3 24G — 3 24G Y1 Y9 4 Y0 4 Y8 5 Vacant 5 Vacant 1 Vacant 1 Vacant 2 Y3 2 YB Y2 YA — 3 24G — 3 24G Y3 YB 4 Y2 4 YA 5 Vacant 5 Vacant 1 Vacant 1 Vacant 2 Y5 2 YD Y4 YC — 3 24G — 3 24G Y5 YD 4 Y4 4 YC 5 Vacant 5 Vacant 1 Vacant 1 Vacant 2 Y7 2 YF Y6 YE — 3 24G — 3 24G Y7 YF 4 Y6 4 YE 5 Vacant 5 Vacant 1 2 3 4 5 Communication circuit LINK IN Communication circuit 1 2 3 4 5 LINK IN Sold by AA Electric 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com n DISTRIBUTED I/O External Connections External Connections Combination Input / Output Modules Detection circuit 1 3 5 2 4 LINK OUT UNIT POWER 1 3 5 2 4 DC/DC Module mounting screw (FG) AUX. 4 2 1 3 5 Three wire type sensor (sink output) Detection circuit 4 2 3 1 5 Terminal resistor setting switch R R R Two wire type sensor (sink output) R R R R R Pin no. 1 2 3 4 5 R Pin no. 1 2 3 4 5 Pin no. X0 — X1 X2 — X3 X4 — X5 X6 — X7 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 Load L L R R R R R R R R 4 2 1 3 5 Pin layout LINK OUT SLD DB DG DA Vacant AUX. +24V (I/O) Vacant 24G (I/O) Vacant FG 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 R R 4 2 1 3 5 Communication connector LINK IN SLD DB DG DA No pin Power supply connector UNIT POWER +24V (UNIT) Vacant 24G (UNIT) Vacant FG I/O connector Pin no. Pin no. +24V X1 Y8 — 24G Y9 X0 Vacant +24V X3 YA — 24G YB X2 Vacant +24V X5 YC — 24G YD X4 Vacant +24V X7 YE — 24G YF X6 Vacant DC/DC R 4 2 1 3 5 R Load L L Terminal resistor setting switch R 4 2 1 3 5 Two wire type sensor (sink output) R 4 2 1 3 5 4 2 1 3 5 Three wire type sensor (sink output) R 4 2 1 3 5 1 3 5 2 4 I/O connector Four wire type sensor (sink output) Communication circuit 110Ω R R 130Ω Constant voltage circuit I/O connector Four wire type sensor (sink output) 1 3 5 2 4 110Ω R R 130Ω Detection circuit Module mounting screw (FG) AUX. 4 2 3 1 5 4 2 3 1 Communication circuit Detection circuit UNIT POWER LINK IN 4 2 3 1 Detection circuit LINK OUT AJ65FBTA42-16DTE Constant voltage circuit LINK IN Detection circuit Sold by AA Electric 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com AJ65FBTA42-16DT Pin no. +24V Y9 Vacant Y8 Vacant +24V YB Vacant YA Vacant +24V YD Vacant YC Vacant +24V YF Vacant YE Vacant LINK IN Male 2 3 1 4 LINK OUT Female 2 1 4 53 Pin no. 1 2 3 4 5 Pin no. 1 2 3 4 5 Pin no. UNIT POWER/AUX. Male X0 — X1 1 2 3 54 X2 — X3 I/O Female 2 1 4 53 Front view X4 — X5 X6 — X7 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 Communication connector LINK IN SLD DB DG DA No pin Power supply connector UNIT POWER +24V (UNIT) Vacant 24G (UNIT) Vacant FG I/O connector Pin no. Pin no. +24V X1 Y8 — 24G Y9 X0 Vacant +24V X3 YA — 24G YB X2 Vacant +24V X5 YC — 24G YD X4 Vacant +24V X7 YE — 24G YF X6 Vacant Mitsubishi Electric Automation | LINK OUT SLD DB DG DA Vacant AUX. +24V (I/O) Vacant 24G (I/O) Vacant FG 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 Pin no. Vacant Y9 24G Y8 Vacant Vacant YB 24G YA Vacant Vacant YD 24G YC Vacant Vacant YF 24G YE Vacant Distributed I/O 363 AJ65SBTW4-16D Sink input Source input LINK CABL LINK CABL DA DB DG SLD +24V FG 24G 1 2 3 4 5 6 7 Isolation DC/DC Common for module POWER power supply CABL and I/O power supply Four wire type sensor (sink output) Sink Sink/source selector switch R R Source Module mounting screw CON1 4 2 1 3 R R R CON8 4 2 1 3 R Detection circuit CON2 4 2 1 3 R Two wire type sensor (sink output) Detection circuit Detection circuit Detection circuit LINK CABL Four wire type sensor (sink output/sink input) Detection circuit Sink Sink/source selector switch R R R R R CON2 4 2 1 3 R CON8 4 2 1 3 R R R AJ65SBTW4-16DT Common for module power supply and I/O power supply Isolation DC/DC Three wire type sensor (sink output) Three wire type sensor (sink output) Two wire type sensor (sink output) DA DB DG SLD +24V FG 24G Source Module mounting screw CON1 4 2 1 3 Detection circuit Detection circuit Common for module POWER power supply CABL and I/O power supply Four wire type sensor (sink output) 1 2 3 4 5 6 7 1 2 3 4 5 6 7 DA DB DG SLD +24V FG 24G POWER CABL Pin layout Isolation 1 2 3 4 DC/DC Constant voltage circuit Module mounting screw CON1 4 2 1 3 R R AJ65SBTW4-16D Three wire type sensor (sink output) Detection circuit 364 CON8 4 2 1 3 AJ65SBTW4-16DT Pin No. Signal name Pin No. Signal name 1 +24V 1 +24V 2 X8~XF 2 Y8~YF 3 24G 3 24G 4 X0~X7 4 X0~X7 R R Sold by AA Electric 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com n DISTRIBUTED I/O External Connections Sold by AA Electric 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com CC-Link Remote I/O: AJ65SBTCFo-o • AJ65VBTCFo-o • AJ65BTCo-o FCN Connector Type n All I/O wiring terminates in a single 40 pin connector. n Connectors available separately to facilitate wiring harness construction. n All models UL • cUL listed and CE certified. • FCN connector Performance Specifications Number of Input Points Isolation Method Rated Input Voltage ON Voltage OFF Voltage Input Response Time External Connection Wire Type Common Connection Internal Current Consumption DC input (sink/source common type) 32 points Photocoupler 24 VDC 14 V min. 6 V max. 1.5 ms max. One wire type 32 points 1 common 45mA DC input (sink, source type) 32 points Photocoupler 24 VDC 14 V min. 6 V max. 10 ms max. One wire type 32 points 1 common 70mA Input Module Model Name Input Type AJ65SBTCF1-32D AJ65BTC1-32D Output Module Model Name Output Type AJ65SBTCF1-32T Transistor output (sink type) Transistor output (sink type) AJ65BTC1-32T Number of Output Points Isolation Method Rated Load Voltage 32 points Photocoupler 12/24 VDC 32 points Photocoupler AJ65SBTCF1-32DT DC input / transistor output Sink, source type / sink type Number Isolation of I/O Method Points 16 points Photocoupler /photocoupler /16 points AJ65VBTCF1-32DT1 DC input / transistor output Sink, source type / sink type 16 points Photocoupler /16 points /photocoupler I/O Module Model Name I/O Type 12/24 VDC Operating Voltage Maximum Load Current Output Response Time 1 Point 1 Common 0.1A 3.2A 0.1A 2A 24 VDC 24 VDC Internal Current Consumption ON—OFF Surge Suppression 0.5 ms max. 0.5 ms max. 1.5 ms max. 2 ms max. Zener diode One wire type 32 points 1 common 60mA Clamp diode One wire type 32 points 1 common 115mA Maximum Load Operating Voltage Input Output Response Time Current Response 1 1 ON OFF OFF—ON ON—OFF Time Point Common Voltage Voltage 14 V 6V 0.5 ms 1.5 ms 12/24 1.5ms 0.1A 0.8A min. max. max. max. VDC 15 V 3 V 0.5 ms 1.5 ms 12/24 0.2ms 0.1A 1.6A min. max. max. max. VDC Rated Voltage Input External Common Connection OFF—ON Load Connection Wire Type External Surge Connection Wire Suppression Type on Input /Output Sides Zener One wire type diode Zener diode One wire type Common Connection Internal Current Consumption 16 points 1 common /16 points 1 common 50mA 16 points 1 common /16 points 1 common 50mA Module Features AJ65SBTCF1-32 Transmission speed setting switch Operation LED display Setting value Transmission speed Item checked 0 156 kbps PW Turns on when the power supply to the remote I/O module is turned on. 1 625 kbps 2 2.5 Mbps L RUN Turns on when normal data is received from the master station, and turns off via timeout. 3 5.0 Mbps 4 10 Mbps LED name STATION NO. B RATE 40 20 10 8 4 2 1 4 2 1 X0-XF L ERR X0 to 1F Y0 to 1F Turns on in case of a transmission error (CRC error) and turns off via timeout (L RUN also turns off). It turns on if the settings for station number and transmission speed are wrong. It flashes if the stationnumber and transmission-speed settings are changed while the communication is active. ON MITSUBISHI A J65SBTCF1-32D X10-X1F X10 X11 X12 X13 X14 X15 X16 X17 X18 X19 X1A X1B X1C X1D X1E X1F NC NC NC NC X0 X1 X2 X3 X4 X5 X6 X7 X8 X9 XA XB XC XD XE XF NC NC COM COM Station number setting switches "10," "20," and "40" in STATION NO. are used for setting the second digit of the station number. "1," "2," "4," and "8" in STATION NO. are used for setting the first digit of the station number. Displays the on/off status of input. The LEDs turn on in the "On" state, and off in the "Off" state. Input/output display selector switch Terminal block Connector The compact remote I/O module power supply, transmission, and I/O signals are connected here. Connector for input/output signals DIN rail hook Hook for mounting the module to the DIN rail Mitsubishi Electric Automation | Distributed I/O 365 AJ65VBTCF1-32DT1 Transmission speed setting switch Setting value Transmission speed 0 156 kbps 1 625 kbps 2 2.5 Mbps 3 5.0 Mbps 4 10 Mbps Transmission speed setting LED nameswitch 40 S T 20 A 10 T I 8 O 4 N 2 N 1 O 4 B 2 R A T 1 E PW L RUN L ERR Station number setting switches A J65VBTCF1-32DT1 "10," "20," and "40" in STATION NO. are used for setting the second digit of the station number. "1," "2," "4," and "8" in STATION NO. are used for setting the first digit of the station number. LINK CON.A CON.B X0 Y10 XF Y1F X0 to F PW Y10 to 1F L RUN Item checked Turns on when the power supply to the remote I/O module is turned on. Turns on when normal data is received from the master station, and turns off via timeout. Turns on in case of a transmission error (CRC error) and turns off via timeout (L RUN also turns off). It turns on if the settings for station number and transmission speed are wrong. It flashes if the station-number and transmission-speed settings are changed while the communication is active. Displays the on/off status of input. The LEDs turn on in the "On" state, and off in the "Off" state. L ERR One-touch connector for communication Input/output display selector switch DIN rail hook 8 9 A B C D E F PW/AUX. CON.C DIN rail hook 0 1 2 3 4 5 6 7 CON.D One-touch connector for power supply and FG Connector Connector for input/output signals * Side view shows connectors fitted. AJ65BTC1-32 Operation LED display LED name PW L RUN L ERR 0 to F Transmission speed setting switch Item checked Setting value Transmission speed Turns on when the power supply to the remote I/O module is turned on. 0 156 kbps 1 625 kbps Turns on when normal data is received from the master station, and turns off via timeout. 2 2.5 Mbps 3 5.0 Mbps 4 10 Mbps Turns on in case of a transmission error (CRC error) and turns off via timeout (L RUN also turns off). It turns on if the settings for station number and transmission speed are wrong. It flashes if the station-number and transmission-speed settings are changed while the communication is active. Station number setting switches "10," "20," and "40" in STATION NO. are used for setting the second digit of the station number. "1," "2," "4," and "8" in STATION NO. are used for setting the first digit of the station number. Displays the on/off status of input. The LEDs turn on in the "On" state, and off in the "Off" state. MITSUBISHI A J65BTC1-32D B RATE 0 1 PW L RUN SD RD 2 3 L ERR. 4 0 1 2 3 1 2 3 4 5 6 7 8 9 A B C D E F 4 5 6 7 8 9 A B C D E F STATION NO. X10 X1 0 1 9 0 1 2 2 8 3 3 7 6 5 4 6 5 4 A 0 B 1 3 DA +24V DG 4 2 DB 7 5 24G 6 SLD (FG) Terminal block Connector DIN rail hook The compact remote I/O module power supply, transmission, and I/O signals are connected here. Connector for input/output signals Hook for mounting the module to the DIN rail * Side view shows connectors fitted. 366 Sold by AA Electric 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com n DISTRIBUTED I/O Module Features External Dimensions AJ65VBTCF1-32o AJ65SBTCF1-32o 41 Unit: mm 67 46 CON.B X0 Y10 XF Y1F PW L RUN L ERR CON.D STATION NO. B RATE 40 20 10 8 4 2 1 4 2 1 X0-XF 16.5 8 9 A B C D E F PW/AUX. CON.C 118 109 +10 (mounting pitch) Two 4.5mm x 5.1mm mounting holes (for M4 mounting screws) ON MITSUBISHI A J65SBTCF1-32D X10-X1F 20 11 0 1 2 3 4 5 6 7 115 approximate 110° 110 110° 50 X10 X11 X12 X13 X14 X15 X16 X17 X18 X19 X1A X1B X1C X1D X1E X1F NC NC NC NC X0 X1 X2 X3 X4 X5 X6 X7 X8 X9 XA XB XC XD XE XF NC NC COM COM 7.9 16.5 4 31 External Connections Combination Input / Output Module AJ65BTC1-32o 46 9.5 AJ65SBTCF1-32DT1 1 2 3 4 5 LINK CABLE (IN) Two ø4.5mm mounting holes MITSUBISHI 1 2 3 4 5 LINK CABLE (OUT) A J65BTC1-32D 0 1 PW L RUN SD RD 2 3 L ERR. 4 1 2 3 4 5 6 7 8 9 A B C D E F 0 1 2 3 4 5 6 7 8 9 A B C D E F B +24V 4 2 DB UNIT POWER CABLE (IN) 7 5 DG 24G 6 SLD (FG) I/O POWER CABLE (IN) 156 165 UNIT POWER CABLE (OUT) I/O POWER CABLE (OUT) 1 2 3 4 5 1 2 3 4 5 CON.C 1 FG 2 +24V(UNIT) 3 24G(UNIT) 4 NC 5 NC CON.D 1 FG 2 +24V(UNIT) 3 24G(UNIT) 4 NC 5 NC Isolation DC/DC One-touch connector for power supply and FG CON1 B20, A20 R R 3 DA B13, A13 R R 1 CON.A DA DB DG NC SLD CON.B 1 DA 2 DB 3 DG 4 NC 5 SLD 1 2 3 4 5 One-touch connector for communication 65 0 A STATION NO. X10 X1 0 1 9 0 1 2 8 2 3 7 3 6 5 4 6 5 4 56 Sold by AA Electric 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com CON.A 40 A J65VBTCF1-32DT1 LINK B12, A12 I/O power supply L L CON1 B10, A10 B3, A3 B1, A1 I/O power supply (external power supply) B2, A2 Constant voltage circuit L B3, A3 B1, A1 B2, A2 In case I/O power supply and load power supply are common Mitsubishi Electric Automation | Distributed I/O 367 Input Module Combination Input / Output Module AJ65SBTCF1-32D type AJ65SBTCF1-32DT type Module power supply I/O power supply 1 2 3 4 5 6 7 DA DB DG SLD +24V FG 24G B20 B19 B18 B17 B16 B15 B14 B13 B12 B11 B10 B9 B8 B7 B6 B5 A20 A19 A18 A17 A16 A15 A14 A13 A12 A11 A10 A9 A8 A7 A6 A5 B2 B1 X0 X1 X2 X3 X4 X5 X6 X7 X8 X9 XA XB XC XD XE XF X10 X11 X12 X13 X14 X15 X16 X17 X18 X19 X1A X1B X1C X1D X1E X1F COM COM 1 2 3 4 5 6 7 Isolation Module power supply DC/DC B20 B19 B18 B17 B16 B15 B14 B13 A20 A19 A18 A17 A16 A15 A14 A13 A,B12 A,B11 B10 B9 B8 B7 B6 B5 B4 B3 A10 A9 A8 A7 A6 A5 A4 A3 A,B1 A,B2 R R I/O power supply I/O power supply (external power supply) R DA DB DG SLD +24V FG 24G L L X0 X1 X2 X3 X4 X5 X6 X7 X8 X9 XA XB XC XD XE XF COM NC Y10 Y11 Y12 Y13 Y14 Y15 Y16 Y17 Y18 Y19 Y1A Y1B Y1C Y1D Y1E Y1F CTL+ COM- R R R A3 Y1F A,B1 CTL+ A,B2 COM- In case I/O power supply and load power supply are common Output Module Input Module AJ65SBTCF1-32T type AJ65BTC1-32D type Module power supply L L 1 2 3 4 5 6 7 DA DB DG SLD +24V FG 24G B20 B19 B18 B17 B16 B15 B14 B13 B12 B11 B10 B9 B8 B7 B6 B5 A20 A19 A18 A17 A16 A15 A14 A13 A12 A11 A10 A9 A8 A7 A6 A5 B1,2 A1,2 Y0 Y1 Y2 Y3 Y4 Y5 Y6 Y7 Y8 Y9 YA YB YC YD YE YF Y10 Y11 Y12 Y13 Y14 Y15 Y16 Y17 Y18 Y19 Y1A Y1B Y1C Y1D Y1E Y1F CTL+ COM Isolation 1 2 3 4 5 6 7 DC/DC DC24V DA DB DG SLD +24V FG 24G B20~B5 DC/DC R R A20~A5 R R DC24V B1,B2 Constant voltage circuit Load power supply In case I/O power supply and load power supply are common L R Constant voltage circuit R L I/O power supply (external power supply) Isolation DC/DC Output Module AJ65BTC1-32T type B1,2 CTL+ A1,2 COM 1 2 3 4 5 6 7 DC24V DA DB DG SLD +24V FG 24G L L B20~5 R A20~5 R B1,B2 DC12/24V 368 DC/DC A1,A2 Sold by AA Electric 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com n DISTRIBUTED I/O External Connections CC-Link Remote I/O: AJ65VBTSx-n n n n & AJ65VBTCEn n-n n n n Spring Clamp & e-CON Type These I/O blocks enable cost savings through reduced labor & material costs. Spring clamps eliminate the need for wiring lugs and avoid the need for periodic retightening of I/O terminals. The e-CON terminals use the same I/O connection type as the existing CC-Link/LT I/O blocks. UL and cUL listing and CE certifications on most units. Sold by AA Electric 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com Performance Specifications Input Module Model Name Input Type Number Of Input Points Isolation Method Rated Input Voltage Operating Voltage On Voltage Off Voltage Input Response Time OFF-ON External Connection Wire Type Common Connection Wire Gauge Size Internal Current Consumption ON-OFF AJ65VBTS3-16D DC input +COM 16 Photocoupler 24VDC 14VDC min 6VDC max 1.5ms max 1.5ms max Three wire type 16 points 1 common AWG 28 to 16 35mA AJ65VBTS3-32D DC input +COM 32 Photocoupler 24VDC 14VDC min 6VDC max 1.5ms max 1.5ms max Three wire type 16 points 1 common AWG 28 to 16 40mA Number of Output Points Isolation Method Output Module Model Name Output Type Rated Load Maximum Load Current Output Response Time Voltage 1 Point 1 Common OFF-ON ON-OFF Leakage Current Surge External Connection Common Connection Suppression Wire Type Wire Gauge Size Internal Current Consumption AJ65VBTS2-16T Transistor Sink 16 Photocoupler 12/24VDC 0.5A 4A 1ms max 1ms max 0.1mA max Zener diode Two wire type 16 points 1 common AWG 28 to 16 45mA AJ65VBTS2-32T Transistor Sink 32 Photocoupler 12/24VDC 0.5A 4A 1ms max 1ms max 0.1mA max Zener diode Two wire type 16 points 1 common AWG 28 to 16 60mA Number of I/O Points Isolation Method Input/Load Voltage Input Response Time 24VDC/ 24VDC 1.5ms max 0.5A 4A 14VDC min 24VDC/ 24VDC or 12VDC 1.5ms max 0.5A 4A 14VDC min Combined I/O Module Model Name I/O Type Maximum Output Load Current 1 Point AJ65VBTS32-16DT DC input/ transistor output +COM/sink 8/8 Photocoupler/ photocoupler AJ65VBTS32-32DT DC input/ transistor output +COM/sink 16/16 Photocoupler/ photocoupler Input Module Model Name Input Type Input Operating Voltage 1 Common On Voltage Off Voltage Operating Voltage Number Of Input Points Isolation Method Output Response Time Leakage Current Connection Surge Wire Type On Common SuppresInput/ Output Connection sion Sides Internal Current Consumption OFF-ON ON-OFF 6VDC max 1ms max 1ms max 0.1mA max Zener diode Three wire type / Two wire type 16 points/ common 15mA 6VDC max 1ms max 1ms max 0.1mA max Zener diode Three wire type / Two wire type 16 points/ common 50mA Input Response Time Rated Input Voltage On Voltage Off Voltage OFF-ON ON-OFF External Connection Wire Type Common Connection Internal Current Consumption AJ65VBTCE3-8D DC input +COM 8 Photocoupler 24VDC 14VDC min 6VDC max 1.5ms max 1.5ms max Three wire type 8 points 1 common 35mA AJ65VBTCE3-16D DC input +COM 16 Photocoupler 24VDC 14VDC min 6VDC max 1.5ms max 1.5ms max Three wire type 16 points 1 common 35mA Leakage Current Surge Suppression External Connection Wire Type Common Connection Internal Current Consumption 0.1mA max Zener diode Two wire type 8 points 1 common 35mA Output Module Model Name AJ65VBTCE2-8T Combined I/O Module Model Name AJ65VBTCE3216DT Output Type Transistor Isolation Method 8 Photocoupler Sink I/O Type DC input/ transistor output Number Of Output Points Number Of I/O Points +COM/sink 8/8 Isolation Method Photocoupler/ photocoupler Rated Load Maximum Load Current Output Response Time Voltage 1 Point 1 Common OFF-ON ON-OFF 12/24VDC Input/Load Voltage 24VDC/ 24VDC 0.1A 0.8A 1ms max Maximum Output Load Current Input Response Time 1 Point 1.5ms max 0.1A 1ms max Input Operating Voltage 1 Common On Voltage Off Voltage 0.8A 14VDC min 6VDC max Output Response Time OFF-ON ON-OFF 1ms max 1ms max Leakage Current 0.1mA max Connection Surge Wire Type on Common SuppresInput/Output Connection sion Sides Zener diode Three wire type / Two wire type 16 points/ common Internal Current Consumption 40mA External Dimensions Mitsubishi Electric Automation | Distributed I/O 369 Input Module AJ65VBTS3-32D Input Module AJ65VBTS3-16D n DISTRIBUTED I/O Sold by AA Electric 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com 370 External Connections Sold by AA Electric 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com Input Module AJ65VBTCE3-8D Input Module AJ65VBTCE3-16D Mitsubishi Electric Automation | Distributed I/O 371 Output Module AJ65VBTS2-32T n DISTRIBUTED I/O Sold by AA Electric 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com 372 Output Module AJ65VBTS2-16T Sold by AA Electric 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com Output Module AJ65VBTCE2-8T Output Module AJ65VBTCE2-16T Mitsubishi Electric Automation | Distributed I/O 373 Combination Input/Output Module AJ65VBTS32-32DT n DISTRIBUTED I/O Sold by AA Electric 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com 374 Combination Input /Output Module AJ65VBTS32-16DT Sold by AA Electric 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com Combination Input/Output Module AJ65VBTCE32-16DT Mitsubishi Electric Automation | Distributed I/O 375 n Compatible with CC-Link Version V2.0. n Eight analog channels occupy only one station, instead of three with CC-Link V1.10. n High precision analog to digital conversion. n Switchable input ranges for each channel. n Sampling or averaging processing. n One touch connectors reduce installation time and cost (available separately). n Module can be replaced without disrupting the network (when “on line” network connector is used.) n All models UL and cUL listed and CE certified. Performance Specifications Model Name Analog Input AJ65VBTCU-68ADVN Voltage Current Digital Value Input/Output Characteristics *Accuracy (Accuracy Relative to the Maximum Digital Output Value) External Connection Method One-Touch Connector for Communication Applicable One-touch Connector for Power Supply Wire Size One-Touch Connector for Analog I/O Module Mounting Screws or Applicable Metal Fittings Applicable DIN Rail External Power Supply Inrush Current Internal Current Consumption (24 VDC) Weight External Dimensions 376 — 0 to 20 mA DC (input resistance 250 ) 12 bit + sign (-4096 to +4095) Analog input range AJ65VBTCU-68ADV Voltage AJ65VBTCU-68ADI Current Input Range Switching Offset/Gain Setting Maximum Conversion Speed Absolute Maximum Input Number of Analog Input Points Station Type Number of Occupied Stations, Expanded Cyclic Setting CC-Link-Compatible Function Withstand Voltage Isolation Method AJ65VBTCU-68ADIN -10 to + 10 VDC (input resistance 1 m ) — 12-bit + sign (-4096 to +4095) Digital value -10 to +10V User range setting 1 (-10 to +10 V) 0 to 5 V 1 to 5 V User range setting 2 (-10 to +10 V) 0 to 20 mA 4 to 20 mA User range setting (0 to 20 mA) Accuracy Ambient temperature Ambient temperature 0 to 55 ˚C 25 ± 5 ˚C -4000 to +4000 Maximum resolution 2.5mV 0 to 4000 ( % ± 0.3 ± 12digit *) ( % *) ± 0.2 ± 8digit 0 to 4000 1.25mV 1.0mV 1.25mV 5µA 4µA 5µA For each channel Yes 1 ms/channel Voltage: ±30 mA 8 channels/module Remote device station Ver. 1 mode: 3 stations (RWr/RWw 12 words each, RS/RY 32 points) Ver. 2 mode: 1 station (extended word (RWr/RWw) 16 words each, RX/RY 32 points), Quadruple Cyclic transmission, extended cyclic transmission, station-to-station cable length relaxation Between batch of power supply/communication systems and batch of analog inputs: 500 VAC for one minute Between communication system and batch of analog inputs: Photocoupler isolation / Between power supply system and batch of analog inputs: Photocoupler isolation Between channels: No isolation / Communication interface: No isolation One-touch connector for communication [transmission circuit] (5-pin/solderless type. The connector plug is sold separately.) One-touch connector for power supply and FG [module power supply and FG] (5-pin/solderless type. The connector plug is sold separately.) One-touch connector for analog input (4-pin/solderless type. The connector plug is sold separately.) (Optional parts) Online connector for communication: A6CON-LJ5P, online connector for power supply: A6CON-PWJ5P Voltage: ±15 V Communication line: CC-Link dedicated cable compatible with Ver.1.10, 0.5 mm (AWG20) [ø2.2 to 3.3 mm] Shielded power supply 0.5 mm (AWG20) 2 2 2 0.66 to 0.98 mm (AWG18) [ø2.2 to 3.0 mm], wire size 0.08 mm or more 2 ø1.0 to 1.4 mm (A6CON-P214), ø1.4 to 2.0 mm (A6CON-P220), [applicable wire size: 0.14 to 0.2 mm ] ø1.0 to 1.4 mm (A6CON-P514), ø1.4 to 2.0 mm (A6CON-P520), [applicable wire size: 0.3 to 0.3 mm ] 2 2 A6PLT-J65VI TH35-7.5Fe, TH35-7.5Al (compliant to JIS C 2812) 24 VDC(20.4 to 26.4 VDC with a ripple rate of 5% or less) 4.2 A, 1.2 ms max. 0.10A 0.17kg 41(W) x 115(H) x 67(D) * 1 digit refers to one digital unit. Sold by AA Electric 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com n DISTRIBUTED I/O CC-Link Analog Modules: AJ65VBTCU-68ADVN • AJ65VBTCU-68ADIN FCN Connector Type Module Features SELECT/SET switch Connector for communication Connector pin no. Operating condition LED display Sold by AA Electric 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com 54321 Description POWER On: When the power supply is turned Normal mode On: Normal operation On: When the SELECT/SET Pin no. 5 4 3 2 1 Name SLD NC DG DB DA switch is in the SET position RUN Test mode Off: When the SELECT/SET switch is in the SELECT Connector for analog I/O L RUN or central position On: When the communication is normal L ERR. Off: When the communication is normal LED display for offset/gain adjustment Connector pin no. 4321 Transmission speed setting switch Setting value Transmission speed 0 156kbps 1 625kbps Pin no. 4 3 2 1 2 2.5Mbps Name SLD NC V-/I- V+/I+ 3 5.0Mbps 4 10Mbps Station number setting switch "10," "20," and "40" in STATION NO. are used for setting the second digit of the station number. "1," "2," "4," and "8" in STATION NO. are used for setting the first digit of the station number. Connector for power supply Connector pin no. 54321 Mode selector switch Description AJ65VBTCU-68ADVN/68ADIN Pin no. 5 4 3 2 1 Name FGI AG Module -24V Module +24V FG Ver.1mode 0: Normal mode 1: Test mode (user range setting 1) 2: Test mode (user range setting 2) For a detailed description of the connectors, see introduction to CC-Link section External Connections AJ65UBTCU-68AIN Ver.2 mode Ver.1mode Ver.2 mode 3: Normal mode 4: Test mode (user range setting 1) 5: Test mode (user range setting 2) 6 to 7: Not used 0: Normal mode 1: Test mode (user range setting 1) 3: Normal mode 4: Test mode (user range setting 1) 2,5∼7: Not used External Dimensions Unit: mm AJ65VBTCU-68ADVN (in case of voltage input) Signal source: 0 to ±10V *3 CH1 1 V+ 2 V3 NC +15V 500k 500k 4 SLD GND -15V *1 Shield AJ65VBTCU-68ADVN (in case of current input) Signal source 0 to ±20mA 2 CH8 500k 1 I+ 2 I3 NC 250k 500k 4 SLD *1 Shield AG *4 GND Rated plate FG1 *1 For wire, use two-core shielded twisted-pair cable. *2 Note the input resistance of AJ65VBTCU-68ADI. *3 Connect a capacitor of around 0.1 to 0.47 µF (it must be a product that can withstand voltages of 25 V or more) between the V and COM terminals if noise or ripple is generated in the external wiring. *4 Be sure to ground FG1. There are cases where AG should also be grounded if the signal is particularly noisy. The offset or gain value should be set again if the ground wiring is changed after setting the offset or gain value (whether the signals were connected to ground or not). Mitsubishi Electric Automation | Distributed I/O 377 AJ65SBT-64AD Analog Input n Four channels (voltage input / current input). n Switchable input ranges. n Handles analog ranges ±10 VDC and 0 ~ 20mA. n Compact size. n Perform channel averaging without affecting conversion speed. n Certification: UL • cUL • CE AJ65BT-64AD Analog Input n Four channels (voltage input / current input). n Handles analog ranges ±10 VDC and 0 ~ 20mA. n Certification: UL • cUL • CE Performance Specifications Model Name AJ65SBT-64AD AJ65BT-64AD Voltage -10 to +10 VDC (input resistance 1M ) Current 0 to 20 mA DC (input resistance 250 ) -20 to +20 mA DC (input resistance 250 ) 12 bit + sign (-4096 to +4095) 12 bit or 11 bit + sign (0 to 4000, or -2000 to +2000 Digital Value Input/Output Analog input range Digital value Maximum Characteristics -4000 to +4000 0 to 5 V 1.25mV 1 to 5 V 0 to 4000 Current 0 to 20mA 1.0mV ±0.4% 1.25mV (±16 digit*) 0 to 4000 4µA 0 to +20 mA (user range setting 3) 2.5mV 0 to 5 V -2000 to +2000 1.25mV to 20 mA 1mV ±1% 20µA (±40 digit*) 0 to 20mA 0 to +4000,or 10µA 0 to 20mA -2000 to +2000 5µA 4µA Yes 1 ms/channel Voltage: ±15 V, current: ±30 mA 4 channels/module Remote device station 1 station (32 points each for RX/RY, 4 words each for RWr/RWw) 2 stations (32 points each for RX/RY, 8 words each for RWr/RWw) Between batch of power supply/communication systems and batch of analog inputs: 500 VAC for one minute Withstand Voltage Between power supply system and batch of analog inputs: Photocoupler isolation/Between communication system and batch of analog inputs: Photocoupler isolation/Between channels: No isolation 7-point 2-piece terminal block (transmission, power supply), directly mounted 18-point terminal block (analog output area) 27-point terminal block (M3.5) 0.3 to 0.75 mm2 0.75 to 2.00 mm2 M4 x 0.7 mm x 16 mm or more, possible to mount on a DIN rail Module Mounting Screws TH35-7.5Fe, TH35-7.5Al (compliant to JIS C 2812) TH35-7.5Fe, TH35-7.5Al, TH35-15Fe (compliant to JIS C 2812) Applicable Solderless Terminal RAV1.25 to 3.5 (compliant to JIS C 2805) RAV1.25 to 3.5, RAV2 to 3.5 Internal Current Consump. (24 VDC) 0.09A 0.12A Weight 0.20kg 0.35kg 118(W) x 50(H) x 40(D)mm 151.9(W) x 65(H) x 63(D)mm External Dimensions Note: 1 digit refers to one bit. 378 5mV 0 to +4000,or All channels in the batch Station Type Applicable DIN Rail to +10 V For each channel Number of Analog Input Points Applicable Wire Size Ambient temperature 0 to 55°C 4 to 20mA Absolute Maximum Input Isolation Method Accuracy resolution 0 to +10 V -20 5µA Maximum Conversion Speed External Connection Method Maximum 1 to 5 V ±0.2% (±8 digit*) 5µA 4 to 20mA Digital value Voltage/current -10 2.5mV Offset/Gain Setting Number of Occupied Stations Analog input range Voltage -10 to +10 V -10 to +10 V (user range setting 1) 0 to +5 V (user range setting 2) Input Range Switching Accuracy resolution Ambient temperature 0 to 55° Ambient temperature 25± 5° Voltage *Accuracy (Accuracy Relative to the Maximum Digital Output Value) -10 to +10 VDC (input resistance 1M ) Current Analog Input Sold by AA Electric 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com n DISTRIBUTED I/O CC-Link Analog Modules: AJ65SBT-64AD • AJ65BT-64AD Analog to Digital Converter Modules AJ65SBT-64AD Module Features Station number setting switches Operating condition LED display LED name Normal mode L RUN On: When the communication is normal PW On: Normal operation L RUN L ERR. CH1 2 3 4 MITSUBISHI OFFSET GAIN A J65SBT-64AD DA DG +24V DB SLD On: When the transmission speed or station number setting is outside the range L ERR. RUN 24G (FG) SELECT B RATE 4 2 1 ON SET CH1 CH2 CH3 CH4 V+ I+ AG TEST V+ I+ COM SLD COM I+ TEST COM V+ SLD COM V+ I+ (FG1) LED display for offset/gain adjustment CHo OFFSET GAIN 40 OFF OFF OFF OFF : OFF OFF : ON Unit-digit 20 OFF OFF OFF OFF : OFF OFF : ON 10 OFF OFF OFF OFF : ON ON : OFF 8 OFF OFF OFF OFF : OFF OFF : OFF 4 OFF OFF OFF OFF : OFF OFF : ON 2 OFF ON ON OFF : OFF OFF : OFF 1 ON OFF ON OFF : OFF ON : OFF Transmission speed setting switches Normal Always off mode Setting switch Setting value Terminal block 0 1 2 3 4 DIN rail hook The compact remote I/O module power supply, transmission, and I/O signals are connected here. SELECT/SET switch 4 OFF OFF OFF OFF ON 2 OFF OFF ON ON OFF Transmission speed 1 OFF ON OFF ON OFF 156 kbps 625 kbps 2.5 Mbps 5.0 Mbps 10 Mbps AJ65BT-64AD Module Features Station number setting switches GAIN switch Transmission speed setting switch RESET switch Transmission speed 0 1 2 3 4 Other than 0 to 4 156 kbps (factory setting) 625 kbps 2.5 Mbps 5.0 Mbps 10 Mbps Not used (L ERR. LED turns on and a communication error occurs.) Analog input range setting pins C D MITSUBISHI MELSEC A B RATE J65BT-64AD 0 1 RD L ERR. 4 CH. OFFSET GAIN DA DG +24V DB SLD A J65SBT-64AD 24G (FG) L RUN LED On: When the communication is normal SD LED Turns on during data transmission RD LED Turns on during data reception L ERR. LED On: Communication data error 3 5 OFFSET switch 4 DB 7 +24V DG 2 9 11 CH1 V+ 24G 6 SLD 8 (FG) TEST 10 TEST (4.5) B RATE 4 2 1 ON 15 CH2 V+ COM 14 SLD 17 COM 16 CH2 I+ 19 CH3 I+ 18 CH3 V+ 21 SLD 20 COM 23 CH4 I+ 22 CH4 V+ 25 27 SLD 24 FG1 26 COM AG Unit: mm B RATE STATION NO. X10 X1 0 1 PW STATION NO. 40 20 10 8 4 2 1 13 12 CH1 I+ Two ø4.5mm mounting holes 40 AJ65BT 64RD SELECT On: Normal operation AJ65BT-64AD External Dimensions Unit: mm SW 0 1-4 16.5 OFFSET GAIN Normal mode 9 MODE NORMAL TEST CH. TEST RUN L RUN SD RD 4 0 1 2 3 6 5 4 9 0 1 2 3 8 7 MODE OFFSET 9 0 1 L ERR. 4 6 5 4 2 3 UP RESET SET 2 3 GAIN DOWN SET CH1 CH2 CH3 CH4 V+ I+ AG TEST V+ I+ COM SLD COM I+ TEST COM V+ SLD COM V+ I+ (FG1) 50 MITSUBISHI 4 RUNLED Terminal block Two 4.5 mm x 5.1 mm mounting holes (for M4 mounting screws) 3 On: When the power supply is turned on DA 109 CH1 2 Item checked PW LED 1 118 L RUN L ERR. LED name 2 3 Channel selector switch AJ65SBT-64AD External Dimensions RUN RESET 1 A B * Use D when 0 to 20 mA is used. PW Operating condition LED display 4 The analog input range is set as follows: Voltage Current 0~10V (0~20mA)* A 1~5V 4~20mA B -10~10V -20~20mA C 0~5V 0~20mA D (4.5) 2 3 PW RUN L RUN SD STATION NO. X10 X1 0 1 9 0 1 2 2 8 3 3 7 6 5 4 6 5 4 56 65 Setting number 142.9 151.9 9.5 63 4 Sold by AA Electric 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com RUN STATION NO. 40 20 10 8 4 2 1 10-digit Station no. 1 2 3 4 : 10 11 : 64 Item checked On: When the power supply is turned on PW AJ65SBT-64AD/ AJ65BT-64AD External Connection Diagram In case of voltage input Signal source: 0 to ± 10V *4 Signal source: 0 to ± 10V CH1 V+ I+ COM SLD +15V 500KΩ *1 500KΩ *2 Indicates the input resistance of AJ65SBT-64AD and AJ65BT-64AD, respectively. *3 Connect a capacitor of around 0.1 to 0.47 µF (it must be a product that can withstand voltag - *4 Be sure to ground FG1. There are cases where AG should also be grounded if the signal is particularly noisy. The offset or gain value should be set again if the ground wiring is changed after setting the offset or gain value (whether the signals were connected to ground or not). ー15V *1 Shield *2 In case of current input Signal source: 0 to ± 20mA CH4 V+ *3 I+ COM SLD Signal source: 0 to ± 20mA *1 Shield *5 For wiring, use two-core shielded twisted-pair cable. 250Ω es of 25 V or more) between the V and COM terminals if noise or ripple is generated in the external wiring. GND 500KΩ 250Ω 500KΩ AG FG1 Mitsubishi Electric Automation | Distributed I/O 379 n Compatible with CC-Link V2.0. n Eight analog channels occupy only one station, instead of three with CC-Link V1.10. n High precision analog to digital conversion. n Switchable output ranges for each channel. n Clear or retain analog output when the controller stops. n One-touch connectors reduce installation time and cost (available separately). n Module can be replaced without disrupting the network (when “on-line” network connector is used.) n Certification: UL • cUL • CE Performance Specifications AJ65VBTCU-68DAVN 12 bit + sign (-4096 to +4095) -10 to + 10 VDC (external load resistance: 2 k to 1 M ) Model Name Digital Value Analog Output Input/Output Characteristics *Accuracy (Accuracy Relative to the Maximum Analog Output Value) Digital Analog -4000 to +4000 -10 to +10 V User range setting 1 (-10 to +10 V) 0 to 5 V 1 to 5 V User range setting 2 (0 to 5 V) Voltage 0 to 4000 Output Range Switching Offset/Gain Setting Maximum Conversion Speed Output Short-Circuit Protection Absolute Maximum Output Number of Analog Output Points Station Type Number of Occupied Stations, Expanded Cyclic Setting CC-Link-Compatible Function Isolation Method External Connection Method One-Touch Connector for Communication Applicable Wire Size One-Touch Connector for Power Supply One-Touch Connector for Analog I/O Applicable DIN Rail External Power Supply Inrush Current Internal Current Consumption Weight External Dimensions 380 Accuracy Ambient temperature Ambient temperature 0 to 55 °C 25 ±5 °C ±0.3% (±30 mV) ±0.2% (±20 mV) ±0.3% (±15 mV) ±0.2% (±10 mV) Maximum resolution 2.5mV 1.25mV 1.0mV 1.25mV For each channel Yes 1 ms/channel Yes ±12V 8 channels/module Remote device station Ver. 1 mode: 3 stations (RWr/RWw 12 words each, RS/RY 32 points) Ver. 2 mode: 1 station (extended word (RWr/RWw) 16 words each, RX/RY 32 points), Quadruple Cyclic transmission, extended cyclic transmission, station-to-station cable length relaxation Between communication system and batch of analog outputs: Photocoupler isolation Between power supply system and batch of analog outputs: Photocoupler isolation Between channels: No isolation One-touch connector for communication [transmission circuit] (5-pin/solderless type. The connector plug is sold separately.) One-touch connector for power supply and FG [module power supply and FG] (5-pin/solderless type. The connector plug is sold separately.) One-touch connector for analog input (4-pin/solderless type. The connector plug is sold separately.) (Optional parts) Online connector for communication: A6CON-LJ5P, online connector for power supply: A6CON-PWJ5P Communication line: CC-Link dedicated cable compatible with Ver.1.10, 0.5 mm2 (AWG20) [ ø 2.2 to 3.3 mm] Shielded power supply 0.5 mm2 (AWG20) 2 2 0.66 to 0.98 mm (AWG18) [ ø 2.2 to 3.0 mm], wire size 0.08 mm or more ø1.0 to 1.4 mm (A6CON-P214), ø1.4 to 2.0 mm (A6CON-P220), [applicable wire size: 0.14 to 0.2 mm2 ] ø1.0 to 1.4 mm (A6CON-P514), ø1.4 to 2.0 mm (A6CON-P520), [applicable wire size: 0.3 to 0.3 mm2 ] TH35-7.5Fe, TH35-7.5Al (compliant to JIS C 2812) Metal fitting for CC-Link connector type: A6PLT-J65V1 24 VDC (20.4 to 26.4 VDC with a ripple rate of 5% or less) 4.3 A, 1.2 ms max. 0.15A 0.16kg 41(W) x 115(H) x 63(D) Sold by AA Electric 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com n DISTRIBUTED I/O CC-Link Analog I/O Modules: AJ65VBTCU-68DAVN Digital To Analog Converter Module Module Features SELECT/SET switch Connector for communication Sold by AA Electric 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com Connector pin no. Operating condition LED display 54321 Description POWER Pin no. 5 4 3 2 1 Name SLD NC DG DB DA On: When the SELECT/SET switch is in the SET position Off: When the SELECT/SET switch is in the SELECT or central position On: When the communication is normal Off: When the communication is normal RUN Test mode L RUN L ERR. Connector for analog I/O On: When the power supply is turned on Normal mode On: Normal operation LED display for offset/gain adjustment Connector pin no. 4321 Transmission speed setting switch Setting value Transmission speed 0 156kbps 1 625kbps Pin no. 4 3 2 1 2 2.5Mbps Name SLD NC V-/I- V+/I+ 3 5.0Mbps 4 10Mbps Station number setting switch "10," "20," and "40" in STATION NO. are used for setting the second digit of the station number. "1," "2," "4," and "8" in STATION NO. are used for setting the first digit of the station number. Connector for power supply Connector pin no. 54321 Mode selector switch Description AJ65VBTCU-68DAVN Pin no. 5 4 3 2 1 Name FGI AG Module -24V Module +24V FG Ver.1mode 0: Normal mode 1: Test mode (user range setting 1) 2: Test mode (user range setting 2) * For a detailed description of the connectors, see introduction to CC-Link section. External Connection External Dimensions *1 D/A conversion *2 1 2 3 4 Unit: mm Motor drive module, etc. CH1 V+ NC COM NC Ver.2 mode 3: Normal mode 4: Test mode (user range setting 1) 5: Test mode (user range setting 2) 6 to 7: Not used 2k 1k GND Motor drive module, etc. CH8 V+ NC COM NC 1 2 3 4 2k 1k GND Rated plate *1 For wire, use two-core shielded twisted-pair cable. *2 Connect a capacitor of around 0.1 to 0.47 µF (it must be a product that can withstand voltages of 25 V or more) between the V and COM terminals if noise or ripple is generated in the external wiring. Mitsubishi Electric Automation | Distributed I/O 381 AJ65SBT-64AD Analog Input n Two channels (voltage input / current input) n Handles analog ranges ±10 VDC and 0 ~ 20mA n Switchable analog outputs n Compact size n Certification: UL • cUL • CE AJ65BT-64DAV n Four channels (voltage output) n Handles analog ranges ±10 VDC and 0 ~ 20mA n Certification: UL • cUL • CE AJ65BT-64DAI n Four channels (current output). n Digital values from 0 to +4000 can be converted to analog values of 4 mA to +20 mA n Certification: UL • cUL • CE Performance Specifications Model Name Digital Voltage Value Current Analog Voltage Output Current 12 bit (0 to 4095) -10 to + 10 VDC (external load resistance: 2 k to 1 M ) 0 to 20 mA DC (external load resistance: 0 to 600 ) Analog Output Maximum Resolution - 4000 to +4000 -10 to +10 V 2.5mV - 4000 to +4000 -10 to +10 V (user range setting 1) 2.5mV 0 to 4000 0 to 5 V 1.25mV 0 to 4000 1 to 5 V 1.0mV 0 to 4000 0 to 5 V (user range setting 2) 1.25mV 0 to 4000 0 to 20 mA 5µA 0 to 4000 4 to 20 mA 4µA Current Voltage Digital Value 0 to 20 mA (user range setting 3) 4 to 20 mA DC (external load resistance: 0 to 600 ) Accuracy Ambient Temperature Ambient Temperature 0 to 55°C 25 ±5 °C ±0.4% ±0.2% 5µA (±40mV) (±20mV) ±0.4% ±0.2% (±20mV) (±10mV) ±0.4% ±0.2% (±80µA) (±40µA) Digital Value Analog Output +2000 +10V +1000 +5V 0 ±0 -1000 -5V -2000 -10V Maximum Resolution 5mV Accuracy (Overall) Digital Value Analog Output 4000 +20mA 2000 +12mA 0 +4mA Maximum Resolution ±1 4µA None Yes Max. Conversion Speed 1 ms/channel No. of Analog Output Points 2 channels/module 4 channels/module No. of Occupied Stations 1 station (32 points each for RX/RY, 4 words each for RWr/RWw) 2 stations (32 points each for RX/RY, 8 words each for RWr/RWw) 7-point 2-piece terminal block (transmission, power supply), directly mounted 18-point terminal block (analog output area), M3 screws 17-point terminal block, M3.5 screws 0.3 to 0.75 mm2 0.75 to 2.00 mm2 Connection Terminal Block Applicable Wire Size Module Mounting Screws Applicable DIN Rail Applicable Solderless Term. M4 x 0.7 mm x 16 mm or more, possible to mount on a DIN rail TH35-7.5Fe, TH35-7.5Al (compliant to JIS C 2812) TH35-7.5Fe, TH35-7.5Al, TH35-15Fe (compliant to JIS C 2812) RAV1.25 to 3.5 (compliant to JIS C 2805) RAV1.25 to 3.5, RAV2 to 3.5 Internal Current Consumption (24 VDC) 0.16A Weight 0.2kg 0.2kg 118(W) x 50(H) x 40(D) mm 151.9(W) x 65(H) x 63(D)mm External Dimensions 0.18 A ±1 (±200mA) Yes Output Short-Circuit Protect. Accuracy (Overall) (±0 mV) For each channel Offset/Gain Setting 382 AJ65BT-64DAI 12 bit (0 to +4095) 0 to 4000 Output Range Switching AJ65BT-64DAV 11 bit + sign ( - 2048 to +2047) -10 to + 10 VDC (external load resistance: 2 k to 1 M ) Input/Output Characteristics *Accuracy (Accuracy Relative to the Maximum Analog Output Value) AJ65SBT-62DA 12 bit + sign ( - 4096 to +4095) 0.27A Sold by AA Electric 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com n DISTRIBUTED I/O CC-Link Analog Modules: AJ65SBT-62DA • AJ65SBT-64DAV • AJ65SBT-64DAI Digital To Analog Converter Module AJ65SBT-62DA Module Features Station number setting switches Operating condition LED display Item checked Station no. PW On: When the power supply is turned on RUN Normal mode L RUN On: When the communication is normal 1 2 3 4 : 10 11 : 64 PW RUN L RUN L ERR. CH1 2 OFFSET GAIN MITSUBISHI A J65SBT-62DA DA DG +24V DB SLD 24G (FG) UP SET DOWN B RATE 4 2 1 CH1 ON CH2 TEST NC V+ I+ NC V+ I+ NC NC TEST NC COM NC NC COM NC NC NC On: When the transmission speed or station number setting is outside the range SELECT/SET switch Terminal block DIN rail hook The compact remote I/O module power supply, transmission, and I/O signals are connected here. Hook for mounting the module to the DIN rail External Connections 8 OFF OFF OFF OFF : OFF OFF : OFF 4 2 1 OFF OFF ON OFF ON OFF OFF ON ON ON OFF OFF : : : OFF ON OFF OFF ON ON : : : ON OFF OFF 0 1 2 3 4 Transmission speed 156 kbps 625 kbps 2.5 Mbps 5.0 Mbps 10 Mbps External Dimensions In case of current output Motor power supply module, etc. CH1 Unit: mm Motor power supply module, etc. ~ D/A電源 0 V+ COM 1M GND 118 109 (4.5) *2 CH1 2k V+ COM *1 600 GND PW Motor power supply module, etc. CH2 Motor power supply module, etc. CH2 2k L RUN L ERR. CH1 2 OFFSET GAIN SELECT UP STATION NO. 40 20 10 8 4 2 1 B RATE 4 2 1 ON SET DOWN A J65SBT-62DA 24G (FG) CH1 CH2 NC V+ I+ NC V+ I+ NC NC TEST TEST NC COM NC NC COM NC NC NC ~ COM 1M GND RUN MITSUBISHI DA DG +24V DB SLD 0 V+ ~ V+ COM 40 (4.5) Two 4.5mm x 5.1mm mounting holes (for M4 mounting screws) ~ *2 *1 16.5 In case of voltage output 600 GND For wire, use two-core shielded twisted-pair cable. Connect a capacitor of around 0.1 to 0.47 µF (it must be a product that can withstand voltages of 25 V or more) to the input terminals of an external device if noise or ripple is generated in the external wiring. 4 *1 *2 10 OFF OFF OFF OFF : ON ON : OFF Setting switch 4 2 1 OFF OFF OFF OFF OFF ON OFF ON OFF OFF ON ON ON OFF OFF Setting value Normal Always off mode D/A power supply Unit-digit 20 OFF OFF OFF OFF : OFF OFF : ON Transmission speed setting switches LED display for offset /gain adjustment CHo OFFSET GAIN 10-digit 40 OFF OFF OFF OFF : OFF OFF : ON 50 L ERR. STATION NO. 40 20 10 8 4 2 1 SELECT On: Normal operation AJ65BT-64DAV/DAI Module Features Station number setting switch Station number setting switches Transmission speed setting switch Setting number 0 1 2 3 4 LED name Transmission speed 156 kbps (factory setting) 625 kbps 2.5 Mbps 5.0 Mbps 10 Mbps MITSUBISHI MELSEC A B RATE J65BT-64DAV 0 1 2 3 PW RUN L RUN SD RD L ERR. 4 CH. STATION NO. X10 X1 0 1 9 0 1 2 2 8 3 3 7 6 5 4 6 5 4 OFFSET UP 1 2 3 4 SET GAIN Item checked PW On: When the power supply is turned on RUN Normal mode L RUN On: When the communication is normal SD Turns on during data transmission RESET DOWN On: Normal operation Terminal block RD Turns on during data reception AJ65BT-64DAV L ERR. On: When the baud rate or station number setting is outside the range 1 3 DA 2 5 DG 4 DB 7 +24V 6 SLD 24G 8 (FG) 9 11 13 15 17 19 21 23 25 27 HLD/ HLD/ CH1/ CH2 CH3 CH4 CLR CLR V+ V+ V+ V+ 10 12 14 16 18 20 22 24 26 TEST COM TEST COM COM COM AJ65BT-64DAI 1 3 DA 2 5 DG 4 DB 7 +24V 6 SLD 24G 8 (FG) RESET (reset switch) 9 11 13 15 17 19 21 23 25 27 HLD/ HLD/ CH1/ CH2 CH3 CH4 CLR CLR I+ I+ I+ I+ 10 12 14 16 18 20 22 24 26 TEST COM TEST COM COM COM CH. (CHANNEL) selector switch HLD/CLR setting terminal HOLD is set by short-circuiting the terminals, while CLEAR is set by having no connection between them. OFFSET/GAIN UP/DOWN switch External Dimensions External Connections Unit: mm AJ65BT-64DAI Motor drive module, etc. 2k 1M GND *1 CH1 Motor drive module, etc. *2 14 Two ø4.5mm mounting holes 0 15 B RATE STATION NO. X10 X1 AJ65BT64DAV 600 GND 0 1 PW RUN L RUN SD RD 4 0 1 2 3 6 5 4 4 2k 1M GND 2 3 UP RESET SET DOWN Motor drive module, etc. CH4 0 27 26 ~ CH4 26 6 5 4 2 3 GAIN 25 8 7 MODE OFFSET 9 0 1 L ERR. Motor drive module, etc. 9 0 1 2 3 56 65 14 *2 ~ *1 CH1 13 ~ AJ65BT-64DAV ~ Sold by AA Electric 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com LED name 600 GND 142.9 151.9 63 *1: For wiring, use two-core shielded twisted-pair cable. *2: Connect a capacitor of around 0.1 to 0.47 µF 25V to the input terminals of an external device if noise or ripple is generated in the external wiring. Mitsubishi Electric Automation | Distributed I/O 383 AJ65BT-68TD n Eight thermocouple inputs per module. n Compatible with K, E, J, T, B, R and S thermocouples. n Assign any thermocouple type to each channel. n Enable/disable conversion for each channel. n Disconnection detection. n Select either sampling or moving average processing for each channel. n Automatic cold junction compensation for PT100 RTD. n Certification: UL • cUL • CE AJ65BT-64RD3 / 64RD4 n Four RTD inputs per module. n Enable/disable conversion for each channel. n Disconnection detection. n Offers moving average processing to reduce effects of noise. n Accurate to ±0.25% of full scale measurement. n Certification: UL • cUL • CE Performance Specifications Model name AJ65BT-68TD AJ65BT-64RD3 Temperature Input Range Temperature Detection Value Scaling Value Overall Accuracy Cold-Junction Compensation System (°C) Resolution (°C) Conversion Speed (Sampling Time: ms/ch) Temperature Sensor Input Channel B, R, S, K, E, J, T -200 to 1700 °C -180 to 600 °C 16-bit signed binary ( -2000 to 17000: Value up to the first decimal place x 10) 16-bit signed binary ( -800 to 6000: Value up to the first decimal place x 10) 32-bit signed binary ( -80000 to 600000: Value up to the third decimal place x 1000) 16-bit signed binary (0 to 2000) *1 Isolation Method Applicable Solderless Terminal ±0.1% (accuracy relative to the maximum value) ±0.25% (accuracy relative to the maximum value) ±1.0 0.025°C 40 ms/channel 4 channels/module 8 channels + 1 channel for connecting the Pt100 sensor Remote device station 4 stations (128 points each for RX/RY, 16 words each for RWr/RWw) Between thermocouple input and CC-Link transmission system Between platinum resistance temperature sensor input and CC-Link transmission system and between channels: Transformer isolation : Photo-coupler isolation / Between channels: No isolation RAV1.25 to 3.5 (compliant to JIS C 2805) RAV1.25 to 3.5, RAV2 to 3.5 (compliant to JIS C 2805) 27-point terminal block (M3.5 x 7 screws) Connection Terminal Block 1ms Allowable Momentary Power Failure Period 0.75 to 2.00 mm2 Applicable Wire Size Module Mounting Screws M4 x 0.7 mm x 16 mm or more, possible to mount on a DIN rail Applicable DIN Rail TH35-7.5Fe, TH35-7.5Al, TH35-15Fe (compliant to JIS C 2812) 24 VDC (18 to 30 VDC) External Power Supply Internal Current Consumption (24 VDC) 0.081A 0.17A Weight 0.40kg 0.38kg External Dimensions *1 The calculation method of overall accuracy is as shown below: (Overall accuracy) + (Conversion accuracy) x (Temperature characteristic) + (Operating ambient temperature change) + (Cold-junction compensation accuracy) Here, the operating ambient temperature change denotes a value not within the operating ambient temperature range of 25±5°C. 384 Ambient temperature (20 ˚C or less, 30 ˚C or more) Ambient temperature (20 ˚C or less, 30 ˚C or more) B, R, S , 0.3°C K, E, J, T : 0.1°C 45 ms/channel Station Type Number of Occupied Stations Four wire type Pt100, JPt100 Connectable Platinum Resistance Temp. Sensors Connectable Thermocouples AJ65BT-64RD4 Three wire type Measurement Method 151.9(W) x 65(H) x 63(D) mm Example: In the case of the overall accuracy with operating thermocouple of K, measured temperature of 150°C, and operating ambient temperature of 35°C, the following applies: (±0.5°C) + (±0.06°C) x (5°C) + (±1°C) = ±1.8°C Sold by AA Electric 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com n DISTRIBUTED I/O CC-Link Analog Modules: AJ65BT-68TD • AJ65BT-64RD3 • AJ65BT-64RD4 Temperature Input Modules AJ65BT-68TD Module Features Station setting switches Operating condition LED display Setting number 0 1 2 3 4 Other than 0 to 4 LED name Transmission speed 156 kbps (factory setting) 625 kbps 2.5 Mbps 5 Mbps 10 Mbps Not used (If other than 0 to 4 is set, L ERR. LED turns on and a communication error occurs.) MITSUBISHI MELSEC B RATE A J65BT-68TD SW 0 MODE NORMAL 1∼8 TEST CH. 9 TEST PW RUN L RUN SD RD L ERR. 0 1 4 2 3 MODE 8 7 9 0 1 6 5 4 STATION NO. X10 X1 0 9 0 1 1 2 2 8 3 3 7 6 5 4 6 5 4 OFFSET UP RESET GAIN Select this when ending the test mode and entering normal operation (factory setting) These settings select a channel for which errors are 1 to 8 TEST CH. compensated for in the test mode. Select TEST to compensate for errors. The test mode 9 TEST is entered after 2 seconds. 0 Item checked PW LED On: When the power supply is turned on RUNLED Normal mode L RUN LED On: When thecommunication is normal SET 2 3 DOWN Mode setting switch Turns on during data transmission RD LED Turns on during data reception L ERR. LED On: Communication data error (CRC error) SET Terminal block 1 3 DA 2 5 DG 7 +24V 4 DB 9 CH1+ 11 CH2+ 13 CH3+ 15 CH4+ 17 CH5+ 19 CH6+ 21 CH7+ 23 CH8+ 25 RTD 27 RTD 24G 6 SLD 8 CH1- 10 CH2- 12 CH3- 14 CH4- 16 CH5- 18 CH6 20 CH7- Reset switch Offset/gain setting switch OFFSET GAIN 22 CH8- 24 On: Normal operation SD LED NORMAL Compensation mode of the offset value Compensation mode of the gain value The temperature detection value when the OFFSET/GAIN switch is placed in the SET position, is stored in the internal memory of AJ65BT-68TD as the offset/gain value. UP/DOWN switch Pt100 resistance temperature sensor Resistance temperature sensor for measuring terminal block temperature (attached to the module) 26 (FG) External Connections External Dimensions Amplifier input SW 0 1∼8 9 CH8 Transformer Filter + ー 65.0 MODE NORMAL TEST CH. TEST *1 Make sure to use shielded compensating conductor cable. *2 Make sure to ground. 1 2 STATION NO. X10 X1 0 1 9 0 1 2 2 8 3 3 7 6 5 4 6 5 4 B RATE A J65BT-68TD Transformer Filter Amplifier input + ー MELSEC PW RUN L RUN SD RD L ERR. 0 1 4 2 3 MODE 9 0 8 7 1 6 5 4 OFFSET UP RESET SET 2 3 GAIN DOWN 65.0 MITSUBISHI CH1 Unit: mm Two ø4.5mm mounting holes 56.0 RTD Pt100 Amplifier input 142.9 63 151.9 AJ65BT-64RD3/RD4 Module Features Transmission speed setting switch Setting number 0 1 2 3 4 Other than 0 to 4 Station setting switches Transmission speed 156 kbps (factory setting) 625 kbps 2.5 Mbps 5 Mbps 10 Mbps Not used (If other than 0 to 4 is set, L ERR. LED turns on and a communication error occurs.) MITSUBISHI MELSEC Mode setting switch 0 1~8 9 B RATE A J65BT-64RD SW 0 1∼4 9 MODE NORMAL TEST CH. TEST PW RUN L RUN SD RD L ERR. 0 1 4 MODE 9 0 1 4 2 3 Pins for specifying the platinum resistance temperature sensor type STATION NO. X10 X1 0 1 9 0 1 2 2 8 3 3 7 6 5 4 6 5 4 UP OFFSET When a Pt100 sensor is connected Circuit board 2 3 GAIN PW LED RUNLED L RUN LED SD LED 1 AJ65BT-64RD3 3 DA 2 5 DG 4 DB 7 +24V 6 SLD 9 (FG) 11 A1 24G 8 10 NC 13 b1 12 B1 15 SLD 14 SLD 17 A2 16 NC 19 b2 18 B2 21 A3 20 NC 23 b3 22 B3 25 SLD 24 SLD 27 A4 26 NC b4 B4 1 3 DA 2 5 DG 4 DB 7 +24V 6 SLD 9 (FG) 11 A1 10 24G 8 a1 13 b1 12 B1 15 SLD 14 SLD 17 A2 16 a2 19 b2 18 B2 21 A3 20 a3 B3 23 b3 22 25 SLD 24 RD LED Turns on during data reception OFFSET GAIN L ERR. LED On: Communication data error (CRC error) SLD 27 A4 26 a4 Item checked On: When the power supply is turned on Normal On: Normal operation mode On: When thecommunication is normal Turns on during data transmission Offset/gain setting switch SET AJ65BT-64RD4 Circuit board Station setting switches DOWN LED name Terminal block When a JPt100 sensor is connected RESET SET Select this when ending the test mode and entering NORMAL normal operation (factory setting) These settings select a channel for which errors are TEST CH. compensated for in the test mode. Select TEST to compensate for errors. The test mode TEST is entered after 2 seconds. b4 Compensation mode of the offset value Compensation mode of the gain value The temperature detection value when the OFFSET/GAIN switch is placed in the SET position, is stored in the internal memory of AJ65BT-68TD as the offset/gain value. Reset switch B4 UP/DOWN switch External Connections The highest accuracy can be obtained for AJ65BT64RD4 by using 4-conductor type platinum resistance temperature sensors. Example of connecting a 4-conductor type platinum resistance temperature sensor Two ø4.5mm mounting holes CH1 Internal circuit SLD Shield a1 A1 B1 b1 SLD Constant voltage circuit Internal circuit MITSUBISHI CH1 Unit: mm External Dimensions MELSEC B RATE A J65BT-64RD4 SW MODE 0 NORMAL 1∼4 TEST CH. 9 TEST 0 PW RUN L RUN SD RD L ERR. 1 2 3 4 MODE 9 0 1 4 STATION NO. X10 X1 0 1 9 0 1 2 8 2 3 7 3 6 5 4 6 5 4 OFFSET UP RESET SET 2 3 GAIN DOWN 65 AJ65BT-64RD4 The highest accuracy can be obtained for AJ65BT64RD3 by using 3-conductor type platinum resistance temperature sensors. Example of connecting a 3-conductor type platinum resistance temperature sensor 56 AJ65BT-64RD3 Shield GND SLD 1 a4 A4 B4 b4 SLD GND 1 GND Internal circuit CH4 CH4 Internal circuit Sold by AA Electric 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com Transmission speed setting switch 142.9 151.9 63 *1: According to the operating environment, it may be better to connect in some cases. Mitsubishi Electric Automation | Distributed I/O 385 AJ65BT-D62 n DC input/sink output type. n Preset DC input. n Maximum counting speed: 200 kpps. AJ65BT-D62/D62D/D62D-S1 n 24 bit counter. n 5/12/24 VDC (2 to 5 mA input). n Switchable counting speed. n Four counter functions: • Latch-counter function • Sampling counter function • Periodic pulse-counter function • Count-disable function AJ65BT-D62D n Differential input/sink output type. n Preset DC input. n Maximum counting speed: 400 kpps. AJ65BT-D62D-S1 n Differential input/sink output type. n Preset differential input. n Maximum counting speed: 400 kpps. * Certification: UL • CUL • CE Performance Specifications Model Name Counting Speed Selector Switch Setting Number of channels Phase Count Input Signal Level Signal (øA, øB) Counting Speed (Maximum) AJ65BT-D62 AJ65BT-D62D HIGH side HIGH side LOW side LOW side 5/12/24 VDC, 2 to 5 mA 1 Phase Input 200kpps 10kpps 400kpps 10kpps 400kpps 10kpps 2 Phase Input 200kpps 7kpps 300kpps 7kpps 300kpps 7kpps Counter 24-bit binary 0 to 16777215 Preset up/down counter and ring counter functions 5µs Minimum Count Pulse Width 2.5µs 100µs 2.5µs (1 and 2 phase input) 142µs 50 50 µs µs 71 71 µs µs (1 phase input) (2 phase input) *1 *1 Coincidence Comparison Range Output Comparison Result 2.5µs 1.25 1.25 µs µs (1 phase input) 3.3µs 1.65 1.65 µs µs (2 phase input) *2 100µs 50 50 µs µs (1 phase input) 142µs 2.5˜µs 71 71 µs µs 1.25 1.25 µs µs (2 phase input) *2 (1 phase input) 24-bit binary Setting value < count value, setting value = count value, setting value > count value 5/12/24 VDC, 2 to 5 mA Preset Function Start Response Time Coincidence Output Response Time External Output Station Type Number of Occupied Stations Power Supply Voltage Current Consumption (at 24 VDC) Connection Terminal Block Applicable Wire Size Applicable Solderless Terminal Allowable Momentary Power Failure Period Module Mounting Screws Applicable DIN Rail Weight 70mA 0.41kg *1 The rise and fall time of the input signal should be 2 µs or less and have a duty cycle of 50%. *2 The rise and fall time of the input signal should be 0.1 µs or less and have a duty cycle of 50%. 386 HIGH side 2 channels 1 phase input, 2 phase input EIA standard, RS-422-A differential type line driver level [Equivalent to Am26L31 (Japan Texas Instruments, Inc)] Counting Range Model External Input AJ65BT-D62D-S1 LOW side 5/12/24 VDC, 2 to 5 mA OFF—ON : 0.5 ms max., ON—OFF : 3 ms max. 2A/1 common 0.1 ms max. Remote device station 4 stations 18 to 28.8 VDC 100mA 27-point terminal block (M3.5 x 7 screws) 0.75 to 2.00 mm2 RAV1.25 to 3.5, RAV2 to 3.5 (compliant to JIS C 2805) 1ms M4 x 0.7 mm x 16 mm or more, possible to mount on a DIN rail TH35-7.5Fe, TH35-7.5Al, TH35-15Fe (compliant to JIS C 2812) 3.3µs 100µs 1.65 1.65 µs µs 50 50 µs µs (2 phase input) *2 (1 phase input) 71 71 µs µs (2 phase input) *2 EIA standard, RS-422-A differential type line driver level [Equivalent to Am26L31 (Japan Texas Instruments, Inc)] 5/12/24 VDC, 2 to 5 mA 120mA 0.42kg 142µs Sold by AA Electric 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com n DISTRIBUTED I/O CC-Link High-Speed Counter Modules AJ65BT-D62 • AJ65BT-D62D • AJ65BT-D62D-S1 Transmission speed setting switch Station number setting switches This is used for setting the transmission speed of the highspeed counter module (for data link). The station number of the high-speed counter module should be set within the range from 1 to 61. "X10" is used for setting the ten-digit of the station number. "X1" is used for setting the unit-digit of the station number. Setting number 0 1 2 3 4 Transmission speed 156 kbps (factory setting) 625 kbps 2.5 Mbps 5 Mbps 10 Mbps Other than 0 to 4 Not used (If other than 0 to 4 is set, L ERR. LED turns on and a communication error occurs.) MITSUBISHI MELSEC A CH.2 øA øB DEC PRE F ST. EQU1 EQU2 CH.1 øA øB DEC PRE F ST. EQU1 EQU2 B RATE STATION NO. X10 X1 0 1 0 1 90 1 2 2 8 2 3 3 7 3 4 654 654 RING PLS RESET CH. 1 2 CH. 1 2 ON LOW J65BT-D62 PW RUN L RUN SD RD L ERR. LED display LED name HIGH LED display Item checked Turns on when voltage is applied to the phase A pulse input terminal. Terminal block 1 DEC Turns on when the counter value is decremented. PRE Turns on and remains on when voltage is applied to the RESET terminal. Turns off when the external preset detection reset command signal is asserted. F ST. 3 5 7 9 11 13 15 17 19 21 23 25 On: When the power supply is turned on RUN On: Normal operation L RUN On: When the communication is normal SD Turns on during data transmission RD Turns on during data reception L ERR. On: Communication data error Mode switch 27 Ring counter setting switch 2 4 6 8 10 12 14 16 18 20 22 24 This is used to set whether to enable or disable the ringcounter function. 26 Reset switch Pulse input setting pin (same for CH.2) AJ65BT-D62 Circuit board Turns on when voltage is applied to the F.START terminal. EQU1 Turns on when the counter value is equal to coincidence output setting No. 1. EQU2 Turns on when the counter value is equal to coincidence output setting No. 2. (Not available in AJ65BT-D62D-S1) AJ65BT-D62D CH.1 øB øA AJ65BT-D62D-S1 CH.1 Jumper F ST. (When the jumper is connected to 12 V) (When the jumper is connected to 5 V) CH.1 F ST. PRE F ST. PRE 24V 12V 5V Turns on when voltage is applied to the phase B pulse input terminal. Item checked PW 24V 12V 5V øB 24V 12V 5V LED name øA 24V 12V 5V (When the jumper is connected to 24 V) External Connections Example of connection with a pulse generator (24 VDC) of open-collector output type AJ65BT-D62 510 1/3W Example of connection with a pulse generator (5 VDC) of voltage-output type AJ65BT-D62 510 1/3W Pulse input voltage setting pin * * Pulse generator 4.7K 1/3W Pulse input voltage setting pin* 4.7K 1/3W øA 4.7K 1/3W øA 4.7K 1/3W OUT OUT Twisted shielded cable Twisted shielded cable øA +24V GND E Shield 510 1/3W øA E 510 1/3W Pulse input voltage setting pin * * 4.7K 1/3W Pulse input voltage setting pin* 4.7K 1/3W øB 4.7K 1/3W øB 4.7K 1/3W OUT OUT Twisted shielded cable Twisted shielded cable +24V øB E +24V DC24V External power supply 0V 0V Remark: *Set the pulse input voltage setting pin to the GND E Shield External power supply øB position. DC+5V DC24V 0V 0V Remark: *Set the pulse input voltage setting pin to the position. AJ65BT-D62D-S1 Example of connection with a line driver pulse generator (equivalent to Am26L31) AJ65BT-D62D Pulse generator Twisted shielded cable A A A Pulse generator A E Twisted shielded cable A A A A Twisted shielded cable E Twisted shielded cable PRESET Z B Am26LS32 Z 14050 E External power supply B Am26LS32 B B B B 14050 E B Twisted shielded cable B VCC VCC GND GND Am26LS32 External power supply PRESET E VCC VCC GND GND External Dimensions Direction of view A Unit: mm STATION NO. X10 X1 0 1 90 1 2 8 2 3 7 3 4 654 654 RESET RING PLS CH. 1 2 CH. 1 2 ON LOW CH.2 φB φA FST PRE FST PRE 63 HIGH CH.1 φB φA 24V 12V 5V PW RUN L RUN SD RD L ERR. 2 3 24V 12V 5V 0 1 9.5 B RATE J65BT-D62 CH.2 øA øB DEC PRE F ST. EQU1 EQU2 24V 12V 5V MELSEC A 24V 12V 5V CH.1 øA øB DEC PRE F ST. EQU1 EQU2 56 MITSUBISHI 65 Sold by AA Electric 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com Module Features Rated plate Two ø4.5mm mounting holes 142.9 Direction of view A 151.9 Mitsubishi Electric Automation | Distributed I/O 387 n Decentralized motion control — can be placed anywhere on a CC-Link network. n Supports absolute positioning with Mitsubishi’s intelligent digital servo line. n Differential driver supports pulse output to 400 kpps and 10M distance to amplifiers. n A wide selection of positioning control functions including: • Seven types of home position return functions • Automatic trapezoid and S curve acceleration/deceleration methods n Point table for each axis (up to 600 points). n Certification: UL • cUL • CE Performance Specifications Item Item Specification Number of Control Axes Interpolation Function Control Method 2 axes 2-axis linear interpolation, 2-axis circular interpolation *1 mm, inch, degree, pulse Positioning Data It is possible to set 600 data points (positioning data No.: 1 to 600) per axis Positioning interpolation can be set), speed control, speed/position switch control Windows version 75P A7HGP /SW1RX-AD75P or later PC-9800 series /SW1NX-AD75P or later *2 Starting Time DOS/V PC (IBM PC/AT compatible PC) /SW1IVD-AD75P or later *3 Teaching Module AD75TU (software version D or later) Backup Parameters and positioning data are stored in the flash memory (battery-less). Speed/position switch control: Increment/absolute systemr It is possible to switch between 1 to 65535 (ms) and 1 to 8388608 (ms) It is possible to set 4 patterns for both acceleration and deceleration times. It is possible to switch between 1 to 65535 (ms) and 1 to 8388908 (ms) (same ranges as for the acceleration/deceleration time) 20 ms or less (excluding link scan time) 10136-3000VE (soldering-type, accessory) Applicable Wire Size In case of 10138-3000VE: AWG#2 to #30 (approximately 0.05 to 0.2 SQ) In case of 10138-6000VE: AWG#28 (approximately 0.08 SQ) Absolute system Positioning Connector *4 Locus control: Increment/absolute system Maximum Output Pulse When connected to differential driver: 400 kbps When connected to open collector: 200 kbps When connected to differential driver: 10 m • -214748364.8 to 214748364.7 (µm)/ -13421772.8 to 13421772.7 (µm) *5 Maximum Connection Distance Between Servos • -21474.83648 to 21474.83647 (inch)/ -1342.17728 to 1342.17727 (inch) Station type Intelligent device station • 0 to 359.99999 (degree)/0 to 359.99999 (degree) Number of Occupied Stations 4 stations (128 points each for RX/RY, 16 words each for RWr/RWw) • 2147483648 to 2147483647 (pulse)/ -134217728 to 134217727 (pulse) External Power Supply Increment system When connected to open collector: 2 m 24 VDC (20.4 to 26.4 V) Applicable Wire Size 0.75 to 2.00 mm2 Module Mounting Screws M4 x 0.7 mm x 16 mm or more, possible to mount on a DIN rail • -21474.83648 to 21474.83647 (inch)/ -1342.17728 to 1342.17727 (inch) Applicable DIN Rail TH35-7.5Fe, TH35-7.5Al, TH35-15Fe (compliant to JIS C 2812) • -21474.83648 to 21474.8364.7 (degree)/ -1342.17728 to 1342.17727 (degree) Applicable Solderless Terminal RAV1.25 to 3.5, RAV2 to 3.5 • -2147483648 to 2147483647 (pulse)/ -134217728 to 134217727 (pulse) 24 VDC Internal Current Consumption 0.30A • 0 to 214748364.7 (µm)/0 to 13421772.7 (µm) External Dimensions 170(W) x 63.5(H) x 80(D) mm • 0 to 21474.83647 (inch)/0 to 1342.17727 (inch) Weight 0.50kg • -214748364.8 to 214748364.7 (µm)/ -13421772.8 to 13421772.7 (µm) Positioning Range and S-curve acceleration/deceleration *6 10136-6000EL (pressure connection type, sold separately) PTP control: Increment/absolute system Positioning Method Acceleration /Deceleration Time Rapid-Stop Deceleration Time GX Configurator-AP /Software Package Automatic trapezoid acceleration/deceleration PTP (Point to Point) control, locus control (both linear and circular Control Unit Peripheral Device Specification Acceleration /Deceleration Processing Speed/position switch control (increment system) • 0 to 21474.83647 (degree)/0 to 1342.17727 (degree) • 0 to 2147483647 (pulse)/0 to 134217727 (pulse) Speed/position switch control (absolute system) • 0 to 359.99999 (degree)/0 to 359.99999 (degree) 0.01 to 6000000.00 (mm/min)/0.01 to 375000.00 (mm/min) *5 Speed Command 0.001 to 600000.000 (inch/min)/0.001 to 37500.000 (inch/min) 0.001 to 600000.000 (degree/min)/0.001 to 37500.000 (degree/min) 1 to 1000000 (pulse/s)/1 to 62500 (pulse/s) 388 *1 *2 *3 *4 *5 *6 The circular interpolation function is not available when a stepping motor is used. PC-9800 Series is a registered trademark of NEC DOS/V is a registered trademark of IBM Japan, Ltd. In the absolute method, the control unit of the speed/position switch control is "degree" only. Indicates the setting range of "standard mode/stepping motor mode." The automatic S-curve acceleration/deceleration is not available when a stepping motor is used. Sold by AA Electric 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com n DISTRIBUTED I/O CC-Link Positioning Module: AJ65BT-D75P2-S3 Module Features Axis LED display CC-Link status LED display These LEDs display power-supply status and data-communication status. LED name PW These LEDs display information indicating operation status according to the selected mode. On: Normal operation RUN RS-422 connector for peripherals This connector is used for connection with peripheral devices. Item checked On: When the power supply is turned on 17-segment LED display L RUN On: When the communication is normal SD Turns on during data transmission RD Turns on during data reception L ERR. On: Communication data error Transmission speed setting switch Terminal block This is used for setting the data communication speed. Terminal for connecting to the master module Setting number Transmission speed Drive module connectors (AX1 and AX2) 0 156 kbps These connectors are used to connect to drive modules, mechanical system inputs and manual pulse generators. 1 625 kbps 2 2.5 Mbps LED display mode selector switch 3 5 Mbps 4 10 Mbps The information displayed in the "[1] Axis LED display" and the "17-segment LED display" is switched every time this switch is pressed. Station number setting switches These switches are used for setting the station number of D75P2. Reset switch Press this switch to initialize input signal, remote register, and calculation processing. External Dimensions 63.5 9.5 Unit: mm Rated plate 80 Two ø4.5mm mounting holes 71 Sold by AA Electric 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com These LEDs indicate the axis to which the information displayed if the "17-segment LED display" applies. 161 170 Mitsubishi Electric Automation | Distributed I/O 389 n Allows full access to controller programs and memory via the CC-Link network via built-in RS-422 port. n Perform program upload and download from across the network. n Certification: UL • cUL • CE Performance Specifications Model Name AJ65BT-G4-S3 D-sub 25 pin 1 channel Intelligent device station 1 stations (32 points each for RX/RY, 4 words each for RWr/RWw) Peripheral Device Connector Station Type Number of Occupied Stations Allowable Momentary 1ms Power Failure Period RAV1.25 to 3.5, RAV2 to 3.5 (compliant to JIS C 2805) M4 x 0.7 mm x 16 mm screws or larger Possible to mount on a DIN rail TH35-7.5Fe, TH35-7.5Al, TH35-15Fe (compliant to JIS C 2812) 0.19A Applicable Solderless Terminal Module Mounting Screws Applicable DIN Rail 24 VDC Internal Current Consumption External Power Supply (For Driving the Module) 24 VDC (15.6 to 28.8 V) Weight External Dimensions 0.36kg 80(W) x 170(H) X 63.5(D) mm Module Features Transmission speed setting switch Setting number 0 1 2 3 4 Other than 0 to 4 Transmission speed 156 kbps (factory setting) 625kbps 2.5Mbps 5Mbps 10Mbps Not used (If other than 0 to 4 is set, L ERR. LED turns on and a communication error occurs. MITSUBISHI Station number setting switches These switches are used for setting the station number of G4-S3 in the range from 1 to 63 or 1 to 64. B RATE A J65BT-G4-S3 0 1 PW RUN L RUN SD RD L ERR. 4 2 3 SW1 SW6 MODE OFF OFF A ON OFF QnA OFF ON Q ON ON non-used STATION NO. X10 X1 0 1 9 0 1 2 8 2 3 7 3 6 5 4 6 5 4 SW 1 2 3 4 5 6 7 8 RESET ON Reset switch Hardware reset RS-422 Operation setting DIP switch This is used for setting the operation specification of G4-S3. Switch no. 1.6 Terminal block for power supply and data link On: When the power supply is turned on On: Normal operation On: Normal communication Turns on during data transmission Turns on during data reception Off: When the communication is normal RS-422 interface Interface for connecting peripheral devices Peripheral device transmission speed (bps) 4.5 7 8 Not used Not used Test mode SW1 SW6 OFF OFF ON OFF OFF ON ON ON Operation mode A mode QnA mode Q mode Setting not allowed SW2 SW3 OFF OFF ON OFF OFF ON ON ON Transmission speed 9600bps 19200bps 38400bps Setting not allowed Fixed at OFF ---Online mode Test mode External Dimensions Two ø4.5mm mounting holes 9.5 4.5 Unit: mm MITSUBISHI B RATE A J65BT-G4-S3 0 1 63.5 Rated plate PW RUN L RUN SD RD L ERR. 4 SW1 SW6 MODE OFF OFF A ON OFF QnA OFF ON Q ON ON non-used RS-422 4.5 161 170 390 2 3 STATION NO. X10 X1 0 1 9 0 1 2 8 2 3 7 3 6 5 4 6 5 4 SW 1 2 3 4 5 6 7 8 RESET ON 80 PW RUN L RUN SD RD L ERR. 2.3 Status of setting switch ON OFF 71 LED display Setting item Operation mode Sold by AA Electric 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com n DISTRIBUTED I/O CC-Link Peripheral Device Connection Module • AJ65BT-G4-S3 CC-Link Repeater Module • AJ65SBT-RPT Performance Specifications Model Name AJ65SBT-RPT Maximum Number of Connected Modules (Levels) Per Segment 10 Varies depending on the transmission speed. Same as the normal CC-Link system (a system consisting of one segment) Maximum Transmission Distance Of Each Segment Number of Occupied Stations (Stations) None Station Numbers That Can Be Set Power Supply Voltage No station number 20.4 to 26.4 VDC 0.06 A (at TYP 24 VDC) Current Consumption External Dimensions 87.3(W) X 54(H) X 40(D) mm 0.2kg Weight Module Features Operation LED display The status of the module can be checked by the on/off status of the LED display. LED PW At normal operation At hardware test On: The power supply is turned on. Off: The power supply is turned off, or the reset switch is pressed. TEST Reset switch Test switch Pressing this switch resets the module's hardware. (The factory setting is OFF.) Switch status Operation status ON Hardware test OFF Normal operation This is used to set the operating condition of the module. (The factory setting is OFF.) Switch status Operation status ON Hardware test OFF Normal operation On: A hardware test is being performed. Off: During communication operation ERR. On: Hardware error The switch setting value is abnormal. PW On: Communication error The switch setting value is abnormal. TEST Flashing: The switch setting value was changed during operation. Off: Normal Off: Communication is normal. RD1 SD2 RD2 OUT TEST B RATE 4 2 1 ON AJ65SBT-RPT SD1 Flashing: The circuit is normal. Flashing: Transmitting data to the IN side. RD1 RD2 SD1 RESET DA1 SD2 ERR. IN Flashing: The switch setting value was changed during operation. IN Off: The circuit is abnormal. Off: Not transmitting data to the IN side. Flashing: The IN side circuit is normal. Off: The IN side circuit is abnormal. Flashing: Receiving data from the IN side. Off: No reception data from the IN side. Flashing: The circuit is normal. Flashing: Transmitting data to the OUT side. Off: The circuit is abnormal. Off: No data is transmitted to the OUT side. Flashing: The OUT side circuit is normal. Off: The OUT side circuit is abnormal. Flashing: Receiving data from the OUT side. Off: No reception data from the OUT side. DG1 DB1 +24V 24G SLD DA2 (FG) DG2 DB2 OUT NC SLD NC (FG) Transmission speed setting switch This is used for setting the transmission speed of the module. (The factory setting is 0.) Make sure to set the transmission speed in the range below. The "ERR." LED of the LED display turns on if a setting other than the ones listed below is made. IN side terminal block This terminal block is used to connect the CC-Link dedicated cable on the side where the power supply and master station exist. OUT side terminal block This terminal block is used to connect the CC-Link dedicated cable on the side where the master station does not exist. Setting value DIN rail hook Hook for mounting the module to the DIN rail Press on the centerline of the DIN rail hook until it clicks in order to mount the module. Point The settings of the test switch and transmission speed setting switch are valid as made when the power supply to the module is turned off and back on again or the reset switch is turned off. The operations above should be performed again if the settings are changed while the power supply to the module is turned on. System Configuration 0 1 2 3 4 Status of setting switch 4 2 1 OFF OFF OFF OFF OFF ON OFF ON OFF OFF ON ON ON OFF OFF Transmission speed 156kbps 625kbps 2.5Mbps 5Mbps 10Mbps External Connections [Segment] Master station [Segment(first level)] Remote device station Remote I/O station Repeater IN Terminal resistor (mandatory) The following figure shows how to connect AJ65SBT-RPT to the CC-Link system with cables. Intelligent device station (AJ65SBT-RPT) OUT Terminal resistor (mandatory) Terminal resistor (mandatory) Terminal resistor Terminal resistor (mandatory) Repeater (J65SBT-RPT) [1st level] IN OUT Intelligent device station Remote I/O station Remote device station IN OUT AJ65SBT-RPT DA1 DB DB1 DG DG1 CC-Link dedicated cable FG Terminal resistor (mandatory) [2nd level] Master module DA SLD Terminal resistor (mandatory) Terminal resistor Repeater(AJ65SBT-RPT) Local station Remote I/O station SLD FG Remote I/O module DA Terminal resistor DB DG CC-Link dedicated cable SLD FG Local module AJ65SBT-RPT DA1 DA2 DA DB1 DB2 DB DG1 DG2 SLD CC-Link dedicated FG cable SLD FG Terminal resistor DG CC-Link dedicated cable SLD FG Terminal resistor (mandatory) Terminal resistor (mandatory) Terminal resistor *1 The repeater is a module used to connect each segment and extend the CC-Link system. *2 In a CC-Link system using repeaters, a block of devices connected by wiring from one terminal resistor to another terminal resistor is referred to as a segment. (A conventional CC-Link system can be said to be a single-segment configuration.) *3 It is necessary to match the transmission speed of each segment to the transmission speed of the master DA2 AJ65SBT-RPT DA1 DA DB2 DB1 DB DG2 DG1 DG SLD CC-Link dedicated FG cable SLD CC-Link dedicated FG cable SLD Terminal resistor Important It is possible to use CC-Link dedicated cables of different specifications for each segment. However, within each segment CC-Link dedicated cables with the same specifications should be used. Normal data transmission cannot be guaranteed if multiple specifications are used. Point * Make sure to connect a terminal resistor to the modules at both ends of a segment. Terminal resistors should also be connected between DA and DB (between DA1 and DB1 as well as DA2 and DB2 in case of AJ56SBT-RPT). * The terminal resistors used vary according to the type of cable used. For more information, see the user's manual for the master module to be used. * The shielded wire of the CC-Link dedicated cable should be connected to " SLD" of each module, and both sides should be treated with Class D grounding (Class 3 grounding) via "FG ." Note that SDL and FG are connected within the module. FG External Dimensions Terminal resistor 78.3 +10 (mounting pitch) Two 4.5mm x 5.1mm mounting holes (for M4 mounting screws) 40 PW TEST ERR. SD1 RD1 SD2 RD2 16.5 RESET IN OUT TEST B RATE 4 2 1 ON AJ65SBT- RPT 50 DA1 IN DB1 DG1 +24V SLD DA2 24G (FG) OUT DG2 DB2 NC SLD DA2 DA DB2 DB DG2 DG SLD CC-Link dedicated FG cable SLD Terminal resistor FG NC (FG) 87.3 Unit: mm 4 Sold by AA Electric 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com n Allows distance of a CC-Link network to be extended up to 13.2 km with regular BA1SJ61-S or BA1SJ61-P cable. n Use a maximum of 10 repeaters per segment. n Allows T-branch configurations. n Certification: UL • cUL • CE Mitsubishi Electric Automation | Distributed I/O 391 n Allows distance of a CC-Link network to be extended up to 7.8 km using optical fiber cable. n Use in environments where noise is a problem. n Use a maximum of 6 repeaters per segment. n Allows T-branch configurations in regular copper network cable. n Certification: UL • cUL • CE Performance Specifications Model Name AJ65SBT-RPG AJ65SBT-RPS Voltage Power Supply Common Specification 20.4 to 26.4 VDC 0.06 A (at TYP 24 VDC) Current 118(W) x 54(H) x 40(D)mm 0.2kg External Dimensions Weight Terminal resistors (110 x 1, 130 x 1) Supplied Parts CC-Link Communication Specification Optical Communication Specification Maximum Number of Connected Levels in a System 3 levels 2 levels None Number of Occupied Stations Connection Cable Applicable Connector SI-200/220 QSI-185/230 GI-50/125 CA9103S 1000m 2000m CA7003 Maximum Transmission Distance of Optical Fiber Cable Between Repeaters 500m Module Features Operation LED display The status of the module can be checked by the on/off status of the LED display. PW LED name At hardware test TWI.SD TEST B RATE 4 2 1 DA DB On: Hardware error The switch setting value is abnormal. On: Communication error The switch setting value is abnormal. Flashing: The switch setting value was changed during operation. Flashing: The switch setting value was changed during operation. Off: Normal Off: Communication is normal. Flashing: The circuit is normal. Flashing: Not transmitting data to the CCLink side. DG +24V SLD A J65SBT-RPS 24G (FG) Off: Not transmitting data to the CC-Link side. Flashing: Receiving data from the CC-Link side. Off: No reception data from the CC-Link side. Off: The circuit is abnormal. Transmission speed setting switch Flashing: The CC-Link side circuit is normal. Off: The optical communication side circuit is abnormal. OPT.SD Flashing: The circuit is normal. Flashing: Transmitting data to the optical communication side. DIN rail hook Off: The circuit is abnormal. Off: No data is transmitted to the optical communication side. Optical interface Flashing: Receiving data from the optical communication side. Off: No reception data from the optical communication side. Flashing: The CC-Link side circuit is normal. Off: The optical communication side circuit is abnormal. IN OUT TWI.RD OPT.RD RD OPT. MITSUBISHI Off: During communication operation ERR. SD ON TWI. Off: The power supply is turned off. On: A hardware test is being performed. TEST RD TEST ERR. SD At normal operation On: The power supply is turned on. PW Terminal block This terminal block is used for connecting the power supply and CC-Link dedicated cables. Test switch This is used to set the operating condition of the module. (The factory setting is OFF.) Switch status Operation status ON Hardware test OFF Normal operation This is used for setting the transmission speed of the module. (The factory setting is 0.)Make sure to set the transmission speed in the range below. The "ERR." LED of the LED display turns on if a setting other than the ones listed below is made. Status of setting switch 4 2 1 OFF OFF OFF OFF OFF ON OFF ON OFF OFF ON ON ON OFF OFF Setting value 0 1 2 3 4 Transmission speed 156kbps 625kbps 2.5Mbps 5Mbps 10Mbps Point The settings of the test switch and transmission speed setting switch are valid as made while the power supply to the module is turned off and back on again.The operations above should be performed again if the settings are changed while the power supply to the module is turned on. System Configuration [Segment *2 ] Master station *3 Repeater *1 (AJ65SBT-RPS/RPG) Remote I/O station Repeater *1 (AJ65SBT-RPS/RPG) Intelligent device station Combinations of optical repeater module and optical fiber cable to be used The optical repeater modules can be used in the following combinations with optical fiber cable. Optical repeater module [Segment (first level)] *1 Remote I/O station Repeater (AJ65SBT-RPS/RPG) Intelligent Remote device station device station Remote device station [Segment (first level)] Local station Remote I/O station AJ65SBT-RPS AJ65SBT-RPG Remote I/O station Optical fiber cable QSI-type optical fiber cable (maximum extension distance of cable: 1000 m) GI-type optical fiber cable (maximum extension distance of cable: 2000 m) *1 The repeater is a module used to connect each segment and extend the CC-Link system. *2 In a CC-Link system using repeaters, a block of devices connected by wiring from one terminal resistor to another terminal resistor is referred to as a segment. (A conventional CC-Link system can be said to be a single-segment configuration.) *3 It is necessary to match the transmission speed of each segment to the transmission speed of the master station. *4 Up to 3 levels can be used in one segment (up to 2 levels when AJ65SBT-RPG modules are used). Repeater *1 (AJ65SBT-RPS/RPG) [Segment (second level)] *4 Remote I/O station Optical fiber cable SI-type optical fiber cable (maximum extension distance of cable: 500 m) Repeater *1 (AJ65SBT-RPS/RPG) CC-Link dedicated cable Terminal resistor (mandatory) External Dimensions External Connections Unit: mm AJ65SBT-RPS/RPG Remote module DA DA DA DB DB DG DG SLD FG Optical Interface SLD FG Optical fiber cable Optical Interface Terminal resistor DA DA DB DB DG DG SLD 392 Important CC-Link dedicated cables with the same specifications should be used within each segment. Normal data transmission cannot be guaranteed if multiple specifications are used. CC-Link dedicated cable SLD FG FG AJ65SBT-RPS/RPG Local module Terminal resistor Point *Make sure to connect a terminal resistor to the modules at both ends of a segment. Terminal resistors should also be connected between DA and DB. (Terminal resistors are supplied with the module.) *The terminal resistors used vary according to the type of cable used.For more information, see the user's manual for the master module to be used. *The shielded wire of the CC-Link dedicated cable should be connected to " SLD" of each module, and both sides should be treated with Class D grounding (Class 3 grounding) via "F G." Note that SDL and FG are connected within the module. 118 109 +10 (mounting pitch) Two 4.5mm x 5.1mm (for M4 mounting screws) 16.5 CC-Link dedicated cable FG Terminal resistor DG PW TEST ERR. SD RD SD RD TEST B RATE 4 2 1 ON TWI. OPT. MITSUBISHI DA 50 SLD DB CC-Link dedicated cable DB DG +24V SLD A J65SBT-RPS 24G (FG) OUT 4 Terminal resistor Master module 40 The following figure shows how to connect AJ65SBT-RPS/RPG to the CC-Link system with cables. IN Sold by AA Electric 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com n DISTRIBUTED I/O CC-Link Optical Repeater Modules: AJ65SBT-RPS • AJ65SBT-RPG CC-Link Wireless Optical Repeater Module: AJ65B-RPI-10A • AJ65BT-RPI-10B Performance Specifications AJ65BT-RPI-10A • AJ65BT-RPI-10B Model name Power Supply Common Specification CC-Link Communication Specification Voltage Current 20.4 to 26.4 VDC 0.137A (at TYP. 24VDC) External Dimensions Weight 161(W) x 100(H) x 57.5(D) mm Transmission Speed 2.5M/625k/156kbps 0.5kg Maximum Number of Connected Levels in a Segment 2 levels Number of Occupied Stations When the monitoring function is used: 1 (remote I/O station), when the monitoring function is not used: 0 (no station is occupied) Optical Transmission Distance 0 to 100 m When the optical transmission distance is 0 to 50 m: Total angle ±2 Angle of Beam Spread ( °) Optical Communication Specification When the optical transmission distance is 50 to 100 m: Total angle ±1 Modulation Frequency Module A to module B: 36 ± 3 MHz Module B to module A: 44 ±2.5MHz Modulation Method Specially Noted General Specification FSK Ambient Illumination * Must be 10000 lx or less (avoid direct sunlight) *Reference values (based on JIS Z9110) of ambient illumination are shown below. Illumination required for detailed visual work in a plant: 3000 to 1500 lx Illumination required for work in an office: 2000 to 750 lx Module Features S1 S2 S3 RC R1 R2 R3 SLD DG DB LERR ERR DA SD1 RD1 SD2 2 RD2 FG +24V 24G 1 TERMINATER OFF ON 4 5 6 4 5 6 4 5 6 LRUN 3 Enlarged view S B RATE 7 8 C PW 4 5 6 ST NO.X10 7 8 4 5 6 1 LRUN 2 LERR ST NO.X1 7 8 Enlarged view 3 ERR R C 9 0 1 SC PW 1 2 3 4 5 6 RD2 C R C ST NO.X1 7 8 9 0 1 RD1 S B RATE 7 8 ST NO.X10 7 8 2 3 SD2 These are used for fixing the module to the mounting metal fittings. 9 0 1 SD1 Module mounting screws This is the lens surface used for performing optical communication. 9 0 1 ERR Transmission speed 156kbps 625kbps 2.5Mbps Setting not allowed 0 1 2 3 to 9 Lens surface 9 0 1 LERR Setting value 2 3 LRUN Description On: The power supply is turned on. Off: The power supply is turned off. On: Normal communication while the monitoring function is used Off: When a communication error occurred while the monitoring function is used, or while the monitoring function is not used On: When a communication error occurred while the monitoring function is used, or while the monitoring function is not used Off: Normal communication while the monitoring function is used On: Communication error Off: Normal On: Sending data to the cable side Off: Not sending data to the cable side On: Sending data to the optical output side Off: Not sending data to the optical output side On: Receiving data from the connection cable side Off: Not receiving data from the connection cable side On: Receiving data from the optical input side Off: Not receiving data from the optical input side RY (n+1) 0 is turned on. Off: RY (n+1) 0 is turned off. On: RY (n+1) 1 is turned on. Turns on only Off: RY (n+1) 1 is turned off. when the On: RY (n+1) 2 is turned on. monitoring Off: RY (n+1) 2 is turned off. function is used. On: RY (n+1) 3 is turned on. Off: RY (n+1) 3 is turned off. On: Optical reception is enabled for the self-station. Off: Optical reception is disabled for the self-station. On: The margin in light reception of the self-station is 1.5 times or more. Off: The margin in light reception of the self-station is less than 1.5 times. (Using RC as the standard.) On: The margin in light reception of the self-station is 2.0 times or more. Off: The margin in light reception of the self-station is less than 2.0 times. (Using RC as the standard.) On: The margin in light reception of the self-station is 2.5 times or more. Off: The margin in light reception of the self-station is less than 2.5 times. (Using RC as the standard.) 2 3 PW This is used for setting the transmission speed of the module. (The factory setting is 0.) 2 3 LED name Transmission speed setting switch 2 3 The status of the module can be checked by the on/off status of the LED display. 2 3 Operation LED display 9 0 1 Sold by AA Electric 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com n Wireless optical link is ideal for rotating machinery, to replace festoon cabling, etc. n Use “A” and “B” modules as a pair. n Certification: CE 1 FG TERMINATER OFF ON DA SD1 DB DG SLD RD1 SD2 2 +24V 24G RD2 3 Station number setting switch (ten digits) Terminal block Station number setting switch (unit digits) This terminal block is used for connecting the power supply and CC-Link dedicated cable. This is used for setting the station number of the module, and to set whether or not to use the monitoring function. (The factory setting is OFF.) Terminal resistor switch 00 01 to 64 65 to 99 When the monitoring function should not be used Station number when the monitoring function is used Setting not allowed Display window mounting screw This screw is used for fixing the display window to the module. Remove the display window when performing the switch setting. This is used for setting whether or not to use the module's built-in terminal resistor (110 ). (The factory setting is 0.) Mounting metal fittings Metal fittings for mounting the module Point The settings of the transmission speed setting switch and station number setting switches are valid as made while the power supply to the module is turned off and back on again. The operations above should be performed again if the settings are changed while the power supply to the module is turned on. Mitsubishi Electric Automation | Distributed I/O 393 Here it is explained how to connect the AJ65BT-RPI10A/10B to the CC-Link system with the CC-Link dedicated cables. Remove the terminal block protection cover of the modules beforeperforming the wiring work. Terminal resistor Master module AJ65BT-RPI-10A/10B Remote module DA DA DA DB DB DB DG SLD FG DG DG CC-Link dedicated cable Important CC-Link dedicated cables with the same specifications should be used within each segment. Normal data transmission cannot be guaranteed if multiple specifications are used. SLD FG Lens surface CC-Link dedicated cable SLD FG Wireless transmission Terminal resistor Lens surface DA DA DB DB DG DG Point SLD CC-Link dedicated • Make sure to connect a terminal resistor to the modules cable FG at both ends of a segment. Terminal resistors should also be connected between DA and DB. (Terminal resistors are supplied with the module.) AJ65BT-RPI-10A/10B • The terminal resistors used vary according to the type of cable used. For more information, see the user's manual for the master module to be used. • The shielded wire of the CC-Link dedicated cable should be connected to "SLD" of each module, and both sides should be treated with Class D grounding (Class 3 grounding) via "FG." Note that SDL and FG areconnected within the module. SLD FG Local module Module Dimensions Ø mounting hole (for M6 mounting screw) Three Ø 7mm x 16mm mounting holes (for M6 mounting screws) B RATE S C 7 8 5 0 2 3 100.0 84.0 40.0 ST NO.X10 7 8 0 5 LRUN 2 LERR 3 2 3 ST NO.X1 7 8 ERR R C 1 SD1 RD1 SD2 0 5 PW 1 45.0 44.0 2 RD2 2 3 3 35.5 57.5 8.0 130.0 145.0 161.0 128.0 Ø 42 12.0 2.0 35.5 Optical axis adjustment angle ±4° for both left/right and up/down 394 Terminal resistor Unit: mm Terminal resistor Sold by AA Electric 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com n DISTRIBUTED I/O Module Connection CC-Link RS-232 Interface Module: AJ65BT-R2 n Provides a single RS-232 port directly on the CC-Link network. n Allows general purpose RS-232 devices to be located remotely (Printer, barcode, reader, etc.) n Certification: UL • cUL • CE Model Name RS-232 Specification External Connections AJ65BT-R2 Conforms to single-channel RS-232 A Interface Specification The following shows how to connect the pins of the RS-232 interfaces of the AJ65BT-R2 module and the external device. Full duplex communication method Transmission Method Synchronization Method Asynchronous method Transmission Speed 300, 600, 1200, 2400, 4800, 9600, 19200 bps Example of connection where DC code control and DTR/DSR signal control are possible AJ65BT-R2 side (DTE) Signal code Pin no. SD 3 RD 2 RS 7 CS 8 DR 6 SG 5 CD 1 ER 4 (Selected by the RC-232 transmission specification setting switch) Data Format Start Bit 1 Data Bit 7/8 Parity Bit 1 (yes) / 0 (no) 1/2 Stop Bit Error Detection Odd/even parity check/no parity check DTR/DSR (ER/DR) control Communication Control (Flow Control) DC1/DC3 control 15m Transmission Distance General-Purpose I/O Specification Input side: 24 VDC (sink/source common type) 2 points Output side: Transistor output (sink type) 12/24 VDC 2-point terminal block B Example of connection where only DC code control is possible C AJ65BT-R2 side (DTE) Signal code Pin no . Intelligent device station CC-Link Station Type Number of Occupied Signal code SD RD RS CS DR SG CD ER 5120 bytes OS Reception Area Data Link Specification External device (DTE) Cable connection and signal method 1 station (32 points each for RX/RY, 4 words each for RWr/RWw) SD RD RS CS DR SG CD ER Stations Power Supply Voltage 24 VDC Current Consumption Typically 110 mA (24 VDC), 180 mA (16.8 V) maximum EEPROM Writing Life 100,000 times External Dimensions 170(W) x 80(H) x 63.5(D) mm Weight 395g ExtExternal er nal dedevice vice (DTE) (DTE) Cable connection and signal method Signal code SD RD RS CS DR SG CD ER 3 2 7 8 6 5 1 4 Transmission speed setting switch Transmission speed 156kbps 625kbps 2.5Mbps 5Mbps 10Mbps Setting error Setting value 0 1 2 3 4 5to9 Module Features Station number setting switches These switches are used for setting the station number of the module. Reset switch Pressing this switch causes the module to return to the status when the power supply is turned on. RS-232 transmission specification setting switch This is used for setting the RS-232 transmission specification. Number Setting item SW1to 8 Transmission speed SW4 SW5 SW6 SW7 SW8 Not used Number of data bits Parity bit enable/d isable SW Status of setting switch ON OFF 1 2 3 300bps 0 0 0 600bps 1 0 0 1200bps 0 1 0 2400bps 1 1 0 4800bps 0 0 1 9600bps 1 0 1 19200bps 0 1 1 0:OFF 1:ON Terminal block for general-purpose input/output This is used for connecting I/O wires. RS-232 interface External Dimensions Mode setting switch This is for setting the operating condition of the module. Number 0 1 D Name Setting Online mode (The automatic buffer memory update function is not active.) Online mode (The automatic buffer memory update function is active.) Online communication mode. The automatic buffer memory update function is not active. Online communication mode. The automatic buffer memory update function is active. Mode to confir m that the module itself oper ates proper ly . Hardw are test mode Terminal block for data link A twisted pair cable is connected for the power supply and data link (two-piece terminal) Two ø4.5mm mounting holes Unit: mm 4.5 LED name PW RUN Setting item 7 Disable Odd 1 71 80 Description Turns on when the power is normally supplied. Turns on when the module is normal, and turns off at a WDT error. L RUN Turns on when the network communication is normal. Status L ERR. Turns on when the network communication is abnormal (e.g., CRC error). Other SD Flashes when sending data link data. RD Flashes when receiving data link data. XC,XD Status of general-purpose inputs. YC,YD Status of general-purpose outputs. RS-232 SD Turns on when sending RS-232 data. RS-232 RD Turns on when receiving RS-232 data. RS-232 ERR Turns on at an RS-232 transmission error, etc. Initial status This is used for an RS-232 cable connected to an external device. 9.5 Operation LED display 8 Enable Even 2 63.5 Sold by AA Electric 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com Performance Specifications 4.5 161 170 Mitsubishi Electric Automation | Distributed I/O 395 n The AJ65SBT-CLB provides a way to link a CC-Link / LT network to a CC-Link network. n Certification: UL • cUL • CE Performance Specifications Model AJ65SBT-CLB CC-Link Station Type Remote device station Selected between 2, 4 and 8 stations* When 2 stations are selected: 64 points for each of RX/RY (16 points used by the system), 8 words for each of RWr/RWw When 4 stations are selected: 128 points for each of RX/RY (16 points used by the system), 16 words for each of RWr/RWw When 8 stations are selected: 256 points for each of RX/RY When 8 stations are selected: 256 points for each of RX/RY Number of Occupied Stations CC-Link/LT Number of CC-Link Occupied Stations Maximum Number of CC-Link/LT Connected Stations 2 stations occupied 4 stations occupied 8 stations occupied 4-Points Mode 12 stations 28 stations 56 stations 8-Points Mode 6 stations 14 stations 28 stations 16-Points Mode 3 stations 7 stations 14 stations Remote Station Numbers Bridge Station Connection Position 1 to 56 Connected at the end of the trunk line *When 8 stations are occupied, make parameter setting so that two 4-station occupying modules are consecutively connected. 396 Sold by AA Electric 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com n DISTRIBUTED I/O CC-Link — CC-Link / LT Bridge Module Module Features LED Display Operation setting switch PW Lit during correct operation of module. Lit: During correct operation of module Unlit: Clock stop or no power supply L RUN State of data link Lit: Data link e xec resution in prog UnData lit: link eror (time-out) Common L ERR. L RUN auData lt station link f detection Lit: CC-Link side s CRC ault inf reciv BlinkCC-Link : side s ation oper UnNo lit: f ault Description of LED Station number setting switch STATION NO. Use STATION NO. "10," "20" and "40" to set the tens digit of the station number. Use STATION NO. "1," "2," "4" and "8" to set the units digit of the station number. Station No. 1 2 3 4 .. 10 11 .. 63 witchaultsetting f ed data witch ingchanged dur <Du ingr r egular oper ation> Lit: Data link e xec resution in prog UnData lit: link stopped <Self lok teopst -mobade>c Lit: Self loop-bac kmatestl nor UnSelit:lf loop-bac auk telts f Red <Du ingr r egular oper ation> Lit: Data link f ault station detection. Some stations are out of control r BlinkData : link f ault at all stations UnNo lit: f ault <Ink testself lom opde>-bac Lit: Self loop-bac auk telts f UnSelit:lf loop-bac kmatestl nor L ERR. 2. CC-Link/LT part ERR. CC-Link 1. CC-Link part Name Description of LED Color .ange Seautting lt detectfion Lit: L T side s witchaultsetting f BlinkL: T side s witch ingchang oper ed dur UnNo lit: f ault Tens digit 20 OFF OFF OFF OFF 40 OFF OFF OFF OFF 10 OFF OFF OFF OFF 8 OFF OFF OFF OFF 4 OFF OFF OFF ON Units digit 2 OFF ON ON OFF 1 ON OFF ON OFF OFF OFF OFF OFF ON ON OFF OFF OFF OFF OFF OFF OFF ON ON ON OFF OFF OFF ON ON All switches are OFF in the factory shipment state. When two stations are occupied, the setting range is from "1" to "63." When four stations are occupied, the setting range is from "1" to "61." When eight stations are occupied, the setting range is from "1" to "57." Settings out of the permissible range cause a setting error. Transmission speed setting switch Transmission speed setting switch B RATE 4 Setting switch 2 1 Transmission speed 0(Factory shipment setting) OFF OFF OFF 156 kbps 1 2 3 4 OFF OFF OFF ON OFF ON ON OFF ON OFF ON OFF 625 kbps 2.5 Mbps 5.0 Mbps 1 0Mbps Setting ation Settings other than above cause a setting error. Number of occupied stations setting switch NOS: Numbers of Occupied Stations PW CC-Link L RUN L RUN CC-Link/LT L RUN L ERR CC-LINK ERR CC-LINK/LT A J65SBT-CLB 2 1 0(Factory shipment setting) OFF OFF 2 stations 1 2 OFF ON ON OFF 4 stations 8 stations Settings other than above cause a setting error. Self loop-back test setting switch CC-Link / LT OFF: Regular operation mode (Factory shipment setting) ON: Self loop-back test mode Number of points mode setting switch MODE Setting switch 2 1 Setting 0 (Factory shipment state) 1 2 Number of points OFF OFF 8 points OFF ON ON OFF 4 points 16 points Settings other than above cause a setting error. Number of points mode setting switch B RATE CC-Link/LT interface connector Setting switch 2 1 Setting Transmission speed 0 (Factory shipment state) OFF OFF 156kbps 1 2 OFF ON ON OFF 625kbps 2.5Mbps Settings other than above cause a setting error. External Dimensions 87 78 ±0.4 40 10 (4) (4.5) CC-LINK/LT L RUN L ERR ERR CC-LINK STATION NO B RATE CC-LINK/LT NOS TST MODE B RATE INC 22 CC-LINK L RUN L ERR ON (FG) CC-LINK Two 4.5mm x 5.1mm (for M4 mounting screws) 41 ±0.2 49 PW Center of DIN rail (4) 4.5 CC-Link interface connector Number of Occupied Stations Setting switch Setting STATION NO B RATE NOS TST MODE B RATE INC 40 20 10 8 4 2 1 4 2 1 2 1 2 1 2 1 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 CC-Link/LT Sold by AA Electric 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com Name of LED Mitsubishi Electric Automation | Distributed I/O 397 Specifications AJ95FPBA4-16DE Certification Number of Input Points Isolation Method Rated Input Voltage Rated Input Current Operating Voltage Range Max. Simultaneous ON Input Points ON Voltage /ON Current OFF Voltage /OFF Current Input Resistance OFFàON Response Time ONàOFF Common Wiring Method Input Method Number of Stations Occupied Voltage I/O Module Power Supply Current Noise Durability Dielectric Withstand Voltage Insulation Resistance Weight kg (lbs) Level of Protection Required Manual Dimensions (W x H x D) mm (in) Appearance UL • cUL • CE 16 Photocoupler 24 VDC Approx. 7 mA 20.4 to 26.4 VDC (ripple ratio within 5%) 100% 14V or higher / 3.5 mA or higher 6V or lower / 1.7 mA or lower Approx 3.3 kΩ 1.5 ms or lower (when 24 VDC) 1.5 ms or lower (when 24 VDC) 16 points / 1 common (waterproof connector 2 to 4 wire type) Source type 1 station 20.4 to 26.4 VDC (ripple rate: with 5%) 65 mA or lower (when 24 VDC and all points are ON) DC type noise voltage 500Vp-p, noise width 1 µs, noise carrier frequency 25 to 60Hz (noise simulator condition) 500 VAC for 1 minute between all DC external terminals and ground 10 MΩ or higher, measured with a 500 VDC insulation resistance tester 0.40 (0.88) IP67 AJ95FPBA4-16DE User's ManuaI • IB(NA)0800220 (Included) 60 (2.56) x 192 (7.76) x 48 (1.89) External Connection Communication Connector Pin. Number LINK IN LINK OUT 1 Vacant Vacant 2 RxD/TxD(N) RxD/TxD(N) 3 DGND DGND 4 RxD/TxD(P) RxD/TxD(P) 5 Shield Shield Power Supply Connector Pin. Number Unit Power 1 +24V 2 Vacant 3 24G 4 Vacant 5 FG I/O Connector Signal Signal Pin No. Pin No. Name Name X0/X1 X2/X3 X4/X5 X6/X7 398 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 +24V X1 24G X8/X9 X0 Vacant +24V X3 24G XA/XB X2 Vacant +24V X5 24G XC/XD X4 Vacant +24V X7 24G XE/XF X6 Vacant 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 +24V X9 24G X8 Vacant +24V XB 24G XA Vacant +24V XD 24XG XC Vacant +24V XF 24G XE Vacant Sold by AA Electric 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com n DISTRIBUTED I/O Profibus-DP Node Style Waterproof DC Source Input Module, 4 Wire, M12 Connector Sold by AA Electric 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com Profibus-DP Waterproof Source Transistor Output Module, 2 Wire, M12 Connector Specifications Certification Number of Output Points Isolation Method Rated Load Voltage Operating Load Voltage Range Max. Load Current Max. Load Inrush Current Leakage Current at OFF Max. Voltage Drop at ON Output Method OFFàON Response Time ONàOFF Voltage External Power Supply for Output Current Common Wiring Method Surge Supressor Number of Stations Occupied Voltage I/O Module Power Supply Current Noise Durability Dielectric Withstand Voltage Insulation Resistance Weight kg (lbs) Required Manual Dimensions (W x H x D) mm (in) External Connection AJ95FPBA2-16TE UL • cUL • CE 16 points Photocoupler 12 / 24 VDC 10.2 to 26.4 VDC (ripple ratio within 5%) 0.1A / point; 4.0 A/1 common 2.0A 10ms or lower 0.3 mA or lower 0.15 VDC or lower (TYP) 1.0A; 0.2 VDC or lower (MAX) 0.1A Source type with protection (thermal, short circuit) 0.5 ms or lower 1.5 ms or lower (resistive load) 10.2 to 28.8 VDC (ripple ratio: within 5%) Appearance 25 mA or lower (24 VDC/all pts. ON) Not including external load current 16 points / 1 common (waterproof connector 2 wire type) Zener diode 1 station 20.4 to 26.4 VDC (ripple ratio: within 5%) 75mA or lower (when 24 VDC and all points are ON) DC type noise voltage 500Vp-p, noise width 1 µs, noise carrier frequency 25 to 60Hz (noise simulator condition) 500 VAC for 1 minute between all DC external terminals and ground 10 MΩ or higher, measured with a 500 VDC insulation resistance tester 0.40 (0.88) AJ95FPBA2-16TE User’s Manual • IB(NA)0800221 (Included) 60 (2.56) x 192 (7.76) x 48 (1.89) Communication Connector Pin. Number LINK IN LINK OUT 1 Vacant Vacant 2 RxD/TxD(N) RxD/TxD(N) 3 DGND DGND 4 RxD/TxD(P) RxD/TxD(P) 5 Shield Shield Power Supply Connector Pin. Number Unit Power AUX 1 +24V +24V 2 Vacant Vacant 3 24G 24G 4 Vacant Vacant 5 FG FG I/O Connector Signal Signal Pin No. Pin No. Name Name Y0/Y1 Y2/Y3 X4/X5 Y6/Y7 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 Mitsubishi Electric Automation Vacant Y1 24G Y8/Y9 Y0 Vacant Vacant Y3 24G YA/YB Y2 Vacant Vacant Y5 24G YC/YD Y4 Vacant Vacant Y7 24G YE/YF Y6 Vacant | 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 Vacant Y9 24G Y8 Vacant Vacant YB 24G YA Vacant Vacant YD 24G YC Vacant Vacant YF 24G YE Vacant Distributed I/O 399 Specifications Certification INPUT SPECIFICATION Number of Input Points Isolation Method Rated Input Voltage Rated Input Current 8 points Photocoupler 24 VDC Approx. 7mA Operating Voltage Range 20.4 to 26.4 VDC (ripple ratio: within ±5%) Max. Simultaneous on Input Points ON Voltage /ON Current OFF Voltage /OFF Current Input Resistance Response Time OFFàON ONàOFF AJ95FPBA42-16DTE UL • cUL • CE OUTPUT SPECIFICATION Number of Output Points Isolation Method Rated Load Voltage Operating Load Volt. Range Max Load Current 100% 14 V or higher / 35 mA or higher Max Inrush Current Leakage Current at OFF 6 V or lower / 1.7 mA or lower Max. Voltage Drop at ON Approx. 3.3Ω 1.5 ms or lower (when 24 VDC) 1.5 ms or lower (when 24 VDC) Output Form Response Time External Power Supply / Output Input Form Common Wiring Method No. of Stations Occupied Voltage I/O Module Power Supply Current Noise Durability Dielectric Withstand Voltage Insulation Resistance Weight kg (lbs) Required Manual Dimensions (W x H x D) mm (in) Source type 8 points / 1 common (waterproof connector 2 to 4 wire type) OFFàON ONàOFF Voltage Current Surge Suppression Common Wiring Method 8 points Photocoupler 12/24 VDC 10.2 to 28.8 VDC (ripple range ± 5%) 1.0 A / point,: 4.0A/1 common 2.0A 10 msec or lower 0.3 mA or lower 0.15 VDC or lower (TYP) 1.0A 0.2 VDC or lower (MAX) 1.0A Source type with protection (thermal, short circuit) 0.5 msec or lower 1.5 msec or lower (resistive load) 10.2 to 28.8 VDC (ripple rate within 5%) 15mA or lower (24 VDC all pts. ON.) Not including external load current Zener diode 8 points / 1 common (waterproof connector 2 wire type) 1 station 20.4 to 26.4 VDC (ripple rate within 5%) 70 mA or lower (at 24 VDC app pts. ON) DC type noise voltage 500V p-p According to the noise simulator of noise frequency 25 to 60Hz, noise width 1 µs 500 VAC for 1 minute between all DC external terminals and ground 10 MΩ or higher, measured with 500 VDC insulation resistance tester 0.40 AJ95FPBA42-16DTE User’s Manual • IB(NA)0800222 (Included) 60 (2.56) x 192 (7.76) x 48 (1.89) Communication Connector Pin. Number LINK IN LINK OUT 1 Vacant Vacant 2 RxD/TxD(N) RxD/TxD(N) 3 DGND DGND 4 RxD/TxD(P) RxD/TxD(P) 5 Shield Shield Power Supply Connector Pin. Number Unit Power AUX. 1 +24V +24V 2 Vacant Vacant 3 24G 24G 4 Vacant Vacant 5 FG FG I/O Connector Signal Signal Pin No. Pin No. Name Name X0/X1 X2/X3 X4/X5 X6/X7 400 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 +24V X1 24G X0 Vacant +24V X3 24G X2 Vacant +24V X5 24G X4 Vacant +24V X7 24G X6 Vacant Y0/Y1 Y2/Y3 Y4/Y5 Y6/Y7 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 Vacant Y1 24G Y0 Vacant Vacant Y3 24G Y2 Vacant Vacant Y5 24XG Y4 Vacant Vacant Y7 24G Y6 Vacant Sold by AA Electric 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com n DISTRIBUTED I/O Profibus-DP Waterproof Source Transistor Input/Source Transistor Output Module, 4 Wire Input, 2 Wire Output, M12 Connector Profibus Bus I/O: Sold by AA Electric 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com Profibus-DP Bus Node Module The modular format of the MT Profibus I/O modules allows greater flexibility in tailoring a mixture of I/O types to your application. n Special Features: n The bus module connects all I/O modules to the network. n 0.5 transistor output modules. n n n 2A relay output. Isolation between the I/O and network. Screw terminal or spring clamp type terminals. Two selectable types of connecting terminals: screw type and cache clamp terminals. Specifications MT-DP12 Certification Module Type Communications Protocol Medium Interface Operation Modes Communications Rate Max. Total Distance (m) No. of Connectable I/O Modules Addressable Digital I/Os I/O Points Applicable Wire Size (mm 2) Power Supply (VDC) Internal Current Consumption (24 VDC) Weight (kg) Dimensions (W x H x D) mm Optional Accessories Required Manual CE MT I/O bus module, Profibus-DP slave DIN 19245-T3 Shielded twisted-pair 24AWG (0.22 mm 2), impedance: 100 – 130 Ω; Shielded twisted-pair (22AWG =0.34 mm 2), impedance: 135 – 165 Ω RS-485 Sync mode and freeze mode are supported 9.6; 19.2; 93.75; 187.5; 500 kbit/s, 1.5; 3; 6; 12 Mbit/s 4800 (3 repeaters) 16, including up to 4 analog I/O modules 192 — 0.75 – 2.5 24 500 mA (max.) 0.28 (0.62) 96 (3.78)x 114 (4.49) x 60 (2.36) Local system adapter MT-LE with extension cable MT-LE-CBL50 (length 0.5 m) = MT-LE-SET Screw type terminal block MT-DP12-TBS; Cache clamp terminal block MT-DP12-TBC, PROFIBUS 9-pin D-SUB plug connector for up to 12 Mbaud: ProfiCon. IB(NA)6610 Not included (purchase separately) Profibus MT Series Manual. Covers all MT type bus style Profibus I/O Note: Many of these manuals are available by free download from our website, www.meau.com Profibus-DP Bus I/O Choose from 4, 8 or 16 point I/O modules to accurately tailor the I/O system to your application. Specifications Certification Inputs Outputs Output Type Common Terminal Arrangement Isolation Input Voltage (Sensor Supply) Output Voltage Range Max. Switching Voltage Rated Input Current (A) Max. Current 24 VDC (±25%) — — 0.7 24 VDC (±25%) — — 0.7 — Per Group (A) — — ≤1 ≤1 Electronic — LED OFFàON (ms) ONàOFF (ms) Shortcut Protection Status Display for Outputs Error Indicator Connection Terminal Applicable Wire Size (mm 2) External Sensor Supply Internal Power Consumption (8 VDC) mA Weight kg (lb) Dimensions (W x H x D) mm (in) Accessories* MT-X16 CE 16, source — — — Per Output (A) Leakage Current at OFF Response Time MT-X8 CE 8, source — — — Terminal Blocks (Order separately) 0.75 – 2.5 — 25 0.16 (0.35) MT-Y8T MT-Y16T CE CE — — 8 16 Source Transistor Source Transistor 8 8 By optocoupler — — 24 VDC (-1%) 24 VDC (-1%) 30 VDC 30 VDC — — MT-Y8T2 CE — 8 Source Transistor 4 MT-Y4R CE — 4 Relays 1 — 24 VDC (-0.5%) 30 VDC — — 24/110/220 VAC/DC 220 VAC — 2A (24/110/220 VAC) — 0.5 0.5 2 0.25A (110 VDC) 0.1A (220 VDC) — 2.5 2.5 10 — — <50 µA <50 µA 6 µA — ≤1 ≤0.14 ≤0.14 0.3 10 ms ≤1 ≤0.05 ≤0.05 ≤0.08 5 ms Electronic Electronic Electronic Electronic — — All modules have one or two status LEDs per output LED LED LED — — All modules can be fitted with screw type or cache clamp terminal blocks (see accessories) 0.75 – 2.5 0.75 – 2.5 0.75 – 2.5 0.75 – 2.5 0.75 – 2.5 24 VDC (≤20 mA) 24 VDC (≤20 mA) 24 VDC (≤20 mA) 24 VDC (≤20 mA) 24 VDC (≤30 mA) 30 35 60 35 45 0.17 (0.37) 0.16 (0.35) 0.16 (0.35) 0.18 (0.40) 0.175 (0.39) 56(2.20) x 114 (4.49) x 60 (2.36) MT-X8-TBS MT-X16-TBS MT-Y8T-TBS MT-Y16T-TBS MT-Y8T2-TBS MT-Y4R-TBS MT-X8-TBC MT-X16-TBC MT-Y8T-TBC MT-Y16T-TBC MT-Y8T2-TBC MT-Y4R-TBC MT-X16-PTBS MT-Y16T-PTBS MT-X16-PTBC MT-Y16T-PTBS * Guide to terminal block types: TBS = I/O screw terminals, TBC = I/O spring clamp terminals, PTBS = I/O screw type terminals with additional terminals for supplying power to I/O devices, PTBC = I/O spring clamps with additional terminals for supplying power to I/O devices. Mitsubishi Electric Automation | Distributed I/O 401 The MT modular system also allows you to flexibly incorporate analog as well as digital I/O into your Profibus system. Special Features: n 4 separately parameterizable channels per module. n Voltage, current, and temperature input can be set via parameter. Specifications Certification Module Type Number of Channels Analog Input Digital Output Digital Input Analog Output Input Resistance Max. Output Load n n n With the analog input module, current, voltage, and PT100 inputs can be operated in parallel. Two selectable types of connecting terminals: screw type and spring clamp terminals. Standard potential isolation between network and I/O. MT-4AD-N CE Analog input module 4 -10 V – +10 V, -20 mA – +20 mA, 4 – 20 mA, -180 – +600 °C (PT100) Voltage (kΩ) Current (Ω) I/O Characteristics Max. Resolution Max. Conversion Time Isolation Connection Terminal Applicable Wire Size mm 2 Internal Power Consumption (8 VDC) mA Weight kg (lb) Dimensions (W x H x D) mm (in) Accessories (Order Separately) MT-4DAV CE Analog output module 4 — — 16 bits binary (incl. sign) 0 – 10 VDC — — ≥750Ω Digital Input Analog Output 16 bits binary (incl. sign) — — 176 approx. 50 — Analog Input Digital Output -10 to +10 V -4000 to +4000 -20 to+20mA -4000 to +4000 0 –4000 0 –10V 4 to 20mA 0 to +4000 -180 to +600°C -1800 to +6000 -10 to +10 V approx. 2.5mV -20 to +20mA approx. 5µA — 2.5mV 4 to 20mA approx. 4 µA -180 to +600 °C approx. 0.125 °C 50 ms/channel 1 ms/channel Optocoupler isolation Optocoupler isolation Both modules can be fitted with screw type or spring clamp terminal blocks (see accessories). 0.75 – 2.5 0.75 – 2.5 80 60 0.225 (0.50) 0.22 (0.50) 76 x 114 x 60 Screw type terminal block MT-4AD-TBS-S1 Screw type terminal block MT-4DAV-TBS Spring clamp terminal block MT-4AD-TBC-S1 Spring clamp terminal block MT-4DAV-TBC CC-Link/ LT CC-Link/LT offers a cost effective way to network small groups of digital I/O for applications such as in-panel wiring and similar uses. Key features: n n n n n 402 Attach wiring to I/O blocks with no cutting or stripping of cable: devices simply clip on to the cable, leading to significant labor and material cost savings. Fast communication speed. Up to 1024 I/O per segment. Fine granularity of I/O allows placement of small quantities of I/O where required. Can be connected to an existing CC-Link network via the AJ65SBT-CLB bridge module. Sold by AA Electric 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com n DISTRIBUTED I/O Profibus-DP Analog I/O Modules Required Manuals Manual Part Number IB(NA)0800232 Sold by AA Electric 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com SH(NA)080351 IB(NA)0800240E SH(NA)080362E Description QJ61CL12 AJ65SBT-CLB Included? User’s Manual (Hardware) Yes User’s Manual No User’s Manual (Hardware) Yes User’s Manual No JY997D04101 CL1X4-D1B2 User’s Manual Yes JY997D04201 CL1Y4-T1B2 User’s Manual Yes JY997D04301 CL1Y4-R1B2 User’s Manual Yes JY997D05501 CL1Y4-R1B1 User’s Manual Yes JY997D05601 CL1XY4-DT1B2 User’s Manual Yes JY997D05701 CL1XY4-DR1B2 User’s Manual Yes IB(NA)0800233E CL2X8-D1B2 User’s Manual (Hardware) Yes IB(NA)0800234E CL2Y8-TP1B2 User’s Manual (Hardware) Yes JY997D04401 CL1XY8-DT1B2 User’s Manual Yes JY997D04501 CL1XY8-DR1B2 User’s Manual Yes IB(NA)0800256E CL2X8-D1S2 User’s Manual (Hardware) Yes IB(NA)0800257E CL2Y8-TP1S2 User’s Manual (Hardware) Yes JY997D10801 CL1X4-D1S2 User’s Manual Yes JY997D10901 CL1Y4-T1S2 User’s Manual Yes IB(NA)0800235E CL2X8-D1C3V User’s Manual (Hardware) Yes IB(NA)0800236E CL2Y8-TP1C2V User’s Manual (Hardware) Yes IB(NA)0800258E CL2X16-D1C3V User’s Manual (Hardware) Yes IB(NA)0800259E CL2Y16-TP1C2V User’s Manual (Hardware) Yes IB(NA)0800260E CL2XY16-DTP1C5V User’s Manual (Hardware) Yes JY997D10601 CL1X4-D1C3 User’s Manual Yes JY997D10701 CL1Y4-T1C2 User’s Manual Yes IB(NA)0800264E CL2TE-5 User’s Manual (Hardware) Yes IB(NA)0800265E CL2TE-10S User’s Manual (Hardware) Yes IB(NA)0800237E CL2X16-D1M1V User’s Manual (Hardware) Yes IB(NA)0800238E CL2Y16-TP1M1V User’s Manual (Hardware) Yes JY997D03901 CL1X2-D1D3S User’s Manual Yes JY997D04001 CL1Y2-T1D2S User’s Manual Yes JY997D03801 CL1XY2-DT1D5S User’s Manual Yes JY997D09901 CL1-HLD User’s Manual (Hardware) Yes User’s Manual Yes JY997D04601 JY997D06601 CL1PAD1 User’s Manual (Detailed) No JY997D09801 CL1PSU-2A User’s Manual Yes JY997D05901 CL1XY8-DTE1B2 User’s Manual Yes JY997D06301 CL1XY2-DTE1D5S User’s Manual Yes JY997D06501 CL1Y2-TE1D2S User’s Manual Yes JY997D05801 CL1Y4-TE1B2 User’s Manual Yes User’s Manual (Hardware) Yes User’s Manual No User’s Manual (Hardware) Yes User’s Manual No IB(NA)0800289E SH(NA)080417E IB(NA)0800290E SH(NA)080418E CL2AD4-B CL2DA2-B Mitsubishi Electric Automation | Distributed I/O 403 This section presents the current line-up of CC-Link/LT I/O blocks. For the network master modules, please refer to the appropriate controller section. Before using this guide, please read the following guide to nomenclature: CL 1 3 2 4 1 Unit for CC-Link/LT :1 or 2 2 Unit type X: Input Y: Output XY: I/O hybrid 5 7 6 3 Total number of I/O points 2: 4: 8: 16: 5 Connection form 2 points 4 points 8 points 16 points B: C: M: D: 4 I/O specifications Terminal block Sensor connector MIL connector Cable type 7 Shape S:Ultracompact V: Vertical type None: Normal type (horizontal type) 6 Wire type D1: 24VDC input R1: Relay output 2A T1: Transistor output 0.1A TP1: Transistor output 0.1A (with output protection) DT1: 24VDC input/ transistor output 0.1A DR1: 24VDC input/ relay output 2A 1: 2: 3: 5: 1-wire type 2-wire type 2- or 3-wire type Input 2 or 3-wire type, output 2-wire type Note on "1-wire", "2-wire" & "3-wire" terminology Throughout the CC-Link/LT blocks, we reference these terms. These are concise definitions for the following ways to connect I/O devices: • 1 wire: One side of the load is connected to the I/O module terminal block. The other side is connected to a common terminal shared by all devices. • 2 wire: One side of the load is connected to the I/O module terminal block. The other side is connected to a dedicated common terminal for that load on the terminal block. Note that in some cases, the common terminals may be connected internally. • 3 wire: The I/O block is configured to accept loads with three connections (such as various types of sensor, etc) CC-Link/LT Accessories The following connectors and cable for CC-Link/LT are available: NOTE: ALL CONNECTORS AND ACCESSORIES ARE SOLD SEPARATELY. PLEASE INSURE YOU HAVE ALL NECESSARY CONNECTORS BEFORE BEGINNING AN INSTALLATION. Product Model Number Description Quantity Per Box AWG Dedicated Flat Cable CL9-FL4-18-* * Where * * = length (sold by the meter) 10 m N/A Connector Terminating Resistor CL9-CNF-18 CL9-RYVK ECN-A014R ECN-A004Y ECN-A024BL ECN-A104 ECN-A154 ECN-M014R ECN-M024Y ECN-M034OR ECN-M044GN ECN-M054BL ECN-M064GY ECN-M114R ECN-M124Y ECN-M134OR ECN-M144GN ECN-M154BL ECN-M164GY — 10 2 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 — N/A N/A 28 - 24 24 - 22 22 - 20 N/A N/A 26 - 24 26 - 24 26 - 24 22 - 20 22 - 20 22 - 20 26 - 24 26 - 24 26 - 24 22 - 20 22 - 20 22 - 20 — A Type Plug (*1) A Type Receptacle (*1) M Type Plug (*1) Open Sensor Connector M Type Receptacle (*1) MIL Type (*2) Notes: 1. Use with CLXXX-XXCXXX type blocks 2. Use with CLXXX-XXXMXXX type blocks 404 Red Yellow Blue Panel / Wall mounting type Relay connection type Red Yellow Orange Green Blue Gray Red Yellow Orange Green Blue Gray Available from 3rd parties Sold by AA Electric 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com n DISTRIBUTED I/O Guide to CC-Link/LT I/O CC-Link/LT Power Supply Adapter Sold by AA Electric 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com CC-Link/LT requires 24VDC power to be supplied to the network. The two options for doing this are the CL1PAD1 and the CL1PSU-2A. CL1PAD1 allows network power to be derived from a 24VDC supply, whereas the CL1PSU-2A allows a 120VAC supply to be used. CL1PAD1 UL • cUL 28.8VDC Maximum Input Current Insulation Resistance 5.0A 10MΩ across input-FG by 500VDC insulation resistance tester LINK 1 2 3 4 LINK/POWER CL1PAD1 Internal circuit CC-Link/LT interface connector +24V DA DB 24G -DA DB -- LINK 1 2 3 4 LINK/POWER CL1PAD1 Internal circuit Stabilized power supply 24VDC 1 +24V + 2 24G 3 CL1PAD1 to external PSU: screw terminals CL1PAD1 to CC-Link/LT network: CL9-CNF-18 connectors to network cable. External Connection System Dimensions (W x H x D) mm (in) 66 x 85 x 90 (2.5 x 3.3 x 3.5) Specifications CL1PSU-2A Rated Voltage 100, 120, 200, 230, and 240V AC Voltage Allowable Range 85 to 264V AC Rated Current 1.2A / 100V AC 0.7A / 200V AC Rated Frequency 50 or 60Hz Power Fuse 3.15A Inrush Current Output 1 2 3 4 +24V DA DB 24G -DA DB -- Stabilized power supply 24VDC 1 +24V + 2 24G 3 CC-Link/LT interface connector Specifications Certification Maximum Input Voltage Input CC-Link/LT interface connector CC-Link/LT interface connector 1 2 3 4 Max. 50A / 100V AC Max. 60A / 200 Output Voltage 24V DC +10 %/-5 % Output Current 0.01A to 2A Derating occurs according to the ambient temperature and power voltage. [Use the module in a proper range so that the total current consumption of each module does not exceed 2A (except the period immediately after the power is turned on).] Ripple Noise 500mVp-p or below By noise simulator of 1000Vp-p in noise voltage,1 s in noise width, and 25 to 60Hz in frequency Noise Resistance CC-Link/LT to CC-Link Bridge Module The AJ65SBT-CLB allows a CC-Link/LT network segment to be connected to a CC-Link network. The module uses the A6CON-L5P & A6CON-LJ5P network connectors. Model AJ65SBT-CLB CC-Link Station Type Remote device station Selected between 2, 4 and 8 stations *When 2 stations are selected: 64 points for each of RX/RY (16 points used by the system), 8 words for each of RWr/RWw When 4 stations are selected: 128 points for each of RX/RY (16 points used by the system), 16 words for each of RWr/RWw Number Of Occupied Stations When 4 stations are selected: 128 points for each of RX/RY (16 points used by the system), 16 words for each of RWr/RWw When 8 stations are selected: 256 points for each of RX/RY (32 points used by the system), 32 words for each of RWr/RWw CC-Link/LT Number Of CC-Link Occupied Stations Maximum Number of CC-Link/LT Connected Stations 2 stations occupied 4 stations occupied 8 stations occupied 4-Points Mode 12 stations 28 stations 56 stations 8-Points Mode 6 stations 14 stations 28 stations 16-Points Mode 3 stations 7 stations 14 stations Remote Station Numbers Bridge Station Connection Position 1 to 56 Connected at the end of the trunk line Note: When 8 stations are occupied make parameter setting so that two 4-station occupying modules are consecutively connected. Mitsubishi Electric Automation | Distributed I/O 405 n DISTRIBUTED I/O Input Module Model Name Input Type Number Of Input Points Isolation Method Rated Input Voltage OFF-ON ON-OFF External Connection Wire Type Common Connection Internal Current Consumption On Voltage Off Voltage Operating Voltage CL1X4-D1B2 DC +COM/-COM 4 Photocoupler 24VDC 19VDC min 11VDC max 0.5ms/1.5ms max 0.5ms/1.5ms max Two wire 4 points/common 40mA CL2X8-D1B2 DC +COM/-COM 8 Photocoupler 24VDC 19VDC min 11VDC max 0.5ms/1.5ms max 0.5ms/1.5ms max Two wire 8 points/common 40mA Rated Load Voltage Maximum Load Current Output Response Time Output Module Model Name Output Type Sink Number of Output Points Isolation Method 1 Point 1 Common OFF-ON ON-OFF Leakage Current Surge Suppression External Connection Wire Type Common Connection Internal Current Consumption CL1Y4-T1B2 Transistor 4 Photocoupler 12/24VDC 0.1A 0.4A 1.0ms 1.0ms 0.1mA Zener diode Two wire 4 points/common 60mA CL1Y4-R1B2 Relay 4 Mechanical 250VAC/30VDC 2A 4A 10ms 10ms N/A N/A Two wire 4 points/common 65mA CL1Y4-R1B1 Relay 4 Mechanical 250VAC/30VDC 2A 2A 10ms 10ms N/A N/A One wire 1 point/common 65mA CL2Y8-TP1B2 Transistor 8 Photocoupler 12/24VDC 0.1A 0.8A 0.5ms 0.5ms 0.1mA Zener diode Two wire 8 points/common 40mA Combined I/O Module Model Name Sink I/O Type Number of I/O Points Isolation Method Input/Load Voltage Input Response Time Maximum Output Load Current 1 Point Input Operating Voltage 1 Common On Voltage Output Response Time Off Voltage OFF-ON ON-OFF Connection Surge Internal Wire Type Leakage Common Suppres- on Input/ Current Current Connection Output sion Consumption Sides CL1XY4-DT1B2 DC input/ transistor output +COM/ -COM/sink 2/2 Photocoupler/ photocoupler 24VDC/ 24VDC & 12VDC 1.5ms 0.1A 0.2A 19VDC min 11VDC max 1.0ms 1.0ms 0.1mA Zener diode Two wire/ two wire 2 points/ common/ 2 points/ common 55mA CL1XY4-DR1B2 DC input/ relay output +COM/ -COM 2/2 Photocoupler/ mechanical 24VDC/ 250VAC & 30VDC 1.5ms 2A 4A 19VDC min 11VDC max 10ms 10ms N/A N/A Two wire/ two wire 2 points/ common/ 2 points/ common 60mA CL1XY8-DT1B2 DC input/ transistor output +COM/ -COM/sink 4/4 Photocoupler/ photocoupler 24VDC/ 24VDC & 12VDC 1.5ms 0.1A 0.4A 19VDC min 11VDC max 1.0ms 1.0ms 0.1mA Zener diode Two wire/ two wire 4 points/ common/ 4 points/ common 65mA CL1XY8-DR1B2 DC input/ relay output 4/4 Photocoupler/ mechanical 24VDC/ 250VAC & 30VDC 1.5ms 2A 4A 19VDC min 11VDC max 10ms 10ms N/A N/A Two wire/ two wire 4 points/ common / 4 points/ common 70mA Guide to Module Features 406 Input Response Time Sold by AA Electric 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com Performance Specifications: Screw Terminal Modules External Dimensions Sold by AA Electric 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com CL1X4-D1B2 CL1Y4-T1B2 CL2X8-D1B2 CL2Y8-TP1B2 CL1Y4-R1B2 • CL1Y4-R1B1 CL1XY4-DT1B2 • CL1XY4-DR1B2 CL1XY8-DT1B2 • CL1XY8-DR1B2 External Connections Mitsubishi Electric Automation | Distributed I/O 407 Input Module Model Name Input Type CL1X4-D1S2 DC +COM/-COM CL2X8-D1S2 DC +COM/-COM Output Module Model Name Output Type Number Of Input Points Isolation Method Rated Input Voltage 4 Photocoupler 8 Photocoupler Operating Voltage On Voltage Off Voltage 24VDC 19VDC min 11VDC max 24VDC 19VDC min 11VDC max Number of Output Points Isolation Method Rated Load Voltage Maximum Load Current Input Response Time OFF-ON 0.5ms/ 1.5ms max 0.5ms/ 1.5ms max External Connection Wire Type Common Connection Internal Current Consumption 0.5ms/1.5ms max Two wire 4 points/common 40mA 0.5ms/1.5ms max Two wire 8 points/common 40mA ON-OFF Leakage Current Surge Suppression External Connection Wire Type Output Response Time 1 Point 1 Common OFF-ON ON-OFF Common Connection Internal Current Consumption CL1Y4-T1S2 Transistor Sink 4 Photocoupler 12/24VDC 0.1A 0.4A 1.0ms 1.0ms 0.1mA Zener diode Two wire 4 points/common 60mA CL2Y8-TP1S2 Transistor Sink 8 Photocoupler 12/24VDC 0.1A 0.8A 0.5ms 0.5ms 0.1mA Zener diode Two wire 8 points/common 40mA Guide to Module Features External Dimensions CL1X4-D1S2 • CL1Y4-T1S2 CL2X8-D1S2 • CL2Y8-TP1S2 External Connections 408 Sold by AA Electric 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com n DISTRIBUTED I/O Performance Specifications: Spring Clamp Modules Performance Specifications: e-CON (Sensor Connector Modules) Sold by AA Electric 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com Input Module Model Name Input Type Number Of Input Points Isolation Method Rated Input Voltage Operating Voltage On Voltage Off Voltage Input Response Time OFF-ON External Connection Wire Type Common Connection Internal Current Consumption ON-OFF CL1X4-D1C3 DC +COM 4 Photocoupler 24VDC 19VDC min 11VDC max 0.5ms/1.5ms max 0.5ms/1.5ms max Two wire/three wire 4 points/common 35mA CL2X8-D1C3V DC +COM 8 Photocoupler 24VDC 19VDC min 11VDC max 0.5ms/1.5ms max 0.5ms/1.5ms max Two wire/three wire 8 points/common 40mA CL2X16-D1C3V DC +COM 16 Photocoupler 24VDC 19VDC min 11VDC max 0.5ms/1.5ms max 0.5ms/1.5ms max Two wire/three wire 16 points/common 45mA Leakage Current Surge Suppression External Connection Wire Type Common Connection Internal Current Consumption Output Module Model Name Output Type Number Of Output Points Isolation Method Rated Load Maximum Load Current Output Response Time Voltage 1 Point 1 Common OFF-ON ON-OFF CL1Y4-T1C2 Transistor Sink 4 Photocoupler 24VDC 0.1A 0.4A 1.0ms 1.0ms 0.1mA Zener diode Two wire 4 points/common 60mA CL2Y8-TP1C2V Transistor Sink 8 Photocoupler 24VDC 0.1A 0.8A 0.5ms 0.5ms 0.1mA Zener diode Two wire 8 points/common 45mA CL2Y16-TP1C2V Transistor Sink 16 Photocoupler 24VDC 0.1A 1.6A 0.5ms 0.5ms 0.1mA Zener diode Two wire 16 points/common 55mA Number Of I/O Points Isolation Method Input/Load Voltage Input Response Time Combined I/O Module Model Name CL2XY16DTP1C5V I/O Type DC input/ transistor output +COM/sink 8/8 Photocoupler/ photocoupler 24VDC/ 24VDC 0.5ms/ 1.5ms Maximum Output Load Current 1 Point 0.1A Input Operating Voltage 1 Common On Voltage 0.8A 19VDC min Output Response Time Off Voltage OFF-ON ON-OFF 11VDC max 0.5ms 0.5ms Leakage Current Surge Suppression 0.1mA Zener diode Connection Internal Wire Type on Common Current Input/Output Connection Consumption Sides Two wire or three wire/ two wire 8 points/ common/ 8 points/ common 50mA Guide to Module Features External Dimensions CL1X4-D1C3 • CL1Y4-T1C2 CL2X16-D1C3V • CL2Y16-TP1C2V CL2XY16-DTP1C5V CL2X8-D1C3V Mitsubishi Electric Automation | Distributed I/O 409 n DISTRIBUTED I/O Sold by AA Electric 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com 410 External Connections Performance Specifications: MIL Connector Modules Input Module Model Name Sold by AA Electric 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com CL2X16-D1M1V Output Module Model Name CL2Y16-TP1M1V Input Type DC +COM Output Type Transistor Sink Number of input points Isolation Method Rated Input Voltage 16 Photocoupler 24VDC Number of Output Points Isolation Method Rated Load Voltage 16 Photocoupler 12/24VDC Operating Voltage On Voltage Off Voltage 19VDC min 11VDC max Internal Current Consumption ON-OFF External Connection Wire Type Common Connection OFF-ON 0.5ms 1.5ms Two wire 16 points/common 45mA Input Response Time Maximum Load Current Output Response Time 1 Point 1 Common OFF-ON ON-OFF 0.1A 1.6A 1.0ms 1.0ms Leakage Current Surge Suppression External Connection Wire Type 0.1mA Zener diode One wire Common Connection Internal Current Consumption 16 points/ common 50mA Guide to Module Features External Dimensions External Connections Mitsubishi Electric Automation | Distributed I/O 411 Input Module Model Name CL1X2-D1D3S Output Module Model Name CL1Y2-T1D2S Combined I/O Module Model Name CL1XY2DT1D5S Input Type DC +COM Output Type Transistor Sink I/O Type DC input/ transistor +COM/sink Number of Input Points Isolation Method Rated Input Voltage 2 Photocoupler 24VDC Isolation Method 2 Photocoupler 24VDC 0.1A Number of I/O Points Isolation Method Input/Load Voltage Input Response Time 1 Point N/A 0.1A Rated Load Voltage Photocoupler 24VDC/24VD /photocoupler C Guide to Module Features 1 Point Input Response Time OFF-ON ON-OFF 19VDC min 11VDC max 0.5ms/1.5ms max 0.5ms/1.5ms max Maximum Load Current Number of Output Points 1/1 Operating Voltage On Voltage Off Voltage Output Response Time 1 Common OFF-ON ON-OFF 0.2A 1.0ms 1.0ms Maximum Output Load Current 0.1A 19VDC min Common Connection Internal Current Consumption Three wire 2 points/common 40mA Leakage Current Surge Suppression External Connection Wire Type Common Connection Internal Current Consumption 0.1mA Zener diode Two wire Input Operating Voltage 1 Common On Voltage External Connection Wire Type Output Response Time Off Voltage OFF-ON ON-OFF 11VDC max 1.0ms 1.0ms 2 points/common Leakage Current 0.1mA Surge Connection Wire Suppres- Type on Input/ sion Output Sides Zener diode Three wire/ two wire External Dimensions CL1X2-D1D3S • CL1Y2-T1D2S CL1XY2-DT1D5S External Connections CL1X2-D1D3S 412 40mA Common Connection Internal Current Consumption 1 point/common/ 1 point/common 40mA Sold by AA Electric 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com n DISTRIBUTED I/O Performance Specifications: Cable Type Modules Performance Specifications: CL2AD4-B Analog-Digital Converter Module Model Sold by AA Electric 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com Analog Input CL2AD4-B Voltage -10 to 10VDC (input resistance 1MΩ) Current 0 to 20mADC (input resistance 250Ω) Digital Output 15-bit signed binary (-4096 to 4095) Analog Input Range I/O Characteristics, Maximum Resolution, Accuracy (Accuracy Relative To Maximum Value Of Digital Output Value) Voltage Current Conversion Speed -10 to 10V 0 to 10V 0 to 5V 1 to 5V 0 to 20mA 4 to 20mA Accuracy Digital Output Ambient Temp. Ambient Temp. Temperature Max. Resolution Value 25 ± 5°C (*1) 0 to 55°C Coefficient (*3) -4000 to 4000 2.5mV 0 to 4000 ± 0.2% (±8 digit) (*2) ±4% ±80ppm / °C (±8 digit) (*2) (±0.0080% /°C) 0 to 4000 1.25mV 1.0mV 5µA 4µA 200µs / 4 channel (*4) Absolute Maximum Output Voltage: ±15V, current: ±30mA Analog Output 4 channels / 1 module CC-Link/LT Station Type Remote device station Number Of Occupied Stations 16 point mode with four occupied stations (*5) Specific Isolated Area Isolation System Dielectric Withstand Insulation Resistance Voltage Between communication system terminals and all analog input terminals Isolation Between power supply system terminals and all analog input terminals Photocoupler isolated Transformer isolated 1 min. duration of 500VAC 500VDC 10MΩ or more Non-isolated — — Between communication system terminals and power supply system terminals Across channels Connected Terminal Block Applicable Wire Size Applicable Crimping Terminal Installing The Module Supported DIN Rail Module Power Supply (*6) Voltage Direct-coupled, 14-point terminal block (M3 screw) 0.3 to 1.25mm2 RAV1.25-3 (conforming to JIS C2805), V1.25-3 (manufactured by JST Mfg. CO., Ltd.), 1.25-3, TG1.25-3 (manufactured by NICHIFU CO., Ltd.) DIN rail attachment, screw mounting: No restrictions to the mounting orientation with M4 x 0.7mm x 16mm and over. TH35-7.5Fe, TH35-7.5AI (conforming to JIS-C2812) 24 VDC (20.4VDC to 28.8 VDC, ripple ratio: within 5%) Current Consumption 0.070A Start Up Current 0.570A Protection Degree IP2X Weight (kg) 0.15 Notes: 1. Standard accuracy 2. Digital indicates the digital output value 3. Accuracy for each 1°C temperature change 4. The conversion speed of the first order lag filter channel is 400µs when a first order lag filter is used. 5. The number of I/O occupied points (occupied station count) differs depending on the final channel permitted for conversion. 6. A dedicated power supply/supply adaptor is used to supply power. External Dimensions Mitsubishi Electric Automation | Distributed I/O 413 Model CL2DA2-B Digital Input Voltage Current 15-bit signed binary (-4096 to 4095) 15-bit signed binary (-96 to 4095) Analog Output Voltage -10 to 10VDC (external load resistance: 1kΩ to 1MΩ) Current 0 to 20mADC (external load resistance: 0 to 600Ω) Analog Output Range I/O Characteristics, Maximum Resolution, Accuracy (Accuracy Relative To Maximum Value Of Digital Output Value) Voltage Current Conversion Speed -10 to 10V 0 to 10V 0 to 5V 1 to 5V 0 to 20mA 4 to 20mA Accuracy Ambient Temp. Ambient Temp. Temperature Max. Resolution 25 ±5°C (*1) 0 to 55°C Coefficient (*2) -4000 to 4000 ±0.2% ±0.4% 2.5mV (±20mV) (±40mV) ±80ppm /°C 0 to 4000 1.25mV ±0.2% ±0.4% (±10mV) (±20mV) 1.0mV (±0.0080% /°C) 5µA ±0.2% ±0.2% 0 to 4000 (±80µA) (±40µA) 4µA Digital Input Value 200µs / 2 channel Output Short-Circuit Protection Provided Absolute Maximum Output Voltage: ±12V, current: +21mA Analog Output Points 2 channels / 1 module CC-Link/LT Station Type Remote device station Number Of Occupied Stations 16 point mode with two occupied stations (*3) Specific Isolated Area Isolation System Dielectric Withstand Insulation Resistance Voltage Between communication system terminals and all analog input terminals Isolation Between power supply system terminals and all analog input terminals Photocoupler isolated Transformer isolated 1 min. duration of 500VAC 500VDC 10MΩ or more Non-isolated — — Between communication system terminals and power supply system terminals Across channels Connected Terminal Block Applicable Wire Size Applicable Crimping Terminal Installing The Module Supported DIN Rail Module Power Supply (*4) Voltage Direct-coupled, 14-point terminal block (M3 screw) 0.3 to 1.25mm2 RAV1.25-3 (conforming to JIS C2805), V1.25-3 (manufactured by JST Mfg. CO., Ltd.), 1.25-3, TG1.25-3 (manufactured by NICHIFU CO., Ltd.) DIN rail attachment, screw mounting: No restrictions to the mounting orientation with M4 x 0.7mm x 16mm and over. TH35-7.5Fe, TH35-7.5AI (conforming to JIS-C2812) 24 VDC (20.4VDC to 28.8 VDC, ripple ratio: within 5%) Current Consumption 0.170A Start Up Current 0.470A Protection Degree IP2X Weight (kg) 0.15 Notes: 1. Standard accuracy 2. Accuracy for each 1°C temperature change 3. The number of I/O occupied points (occupied station count) differs depending on the final channel permitted for conversion. 4. A dedicated power supply/supply adaptor is used to supply power. External Dimensions 414 Sold by AA Electric 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com n DISTRIBUTED I/O Performance Specifications: CL2DA2-B Digital-Analog Converter Module CC-Link/LT Accessories Sold by AA Electric 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com Common Terminal Blocks CL2TE and CL2TE-10S Use these terminal blocks to increase the number of common terminals on a CC-Link/LT I/O block in order to increase wiring convenience. Cable Type I/O Module Holder CL1-HLD Use this holder to increase the convenience of mounting the cable type I/O modules. Can be bolted down or DIN rail mounted. Mitsubishi Electric Automation | Distributed I/O 415 n DISTRIBUTED I/O MELSEC I/O Link Advantages (Bus Topology) Bus topology of MELSEC-I/O LINK gives an advantage of high reliability. Shutdown of one remote I/O module doesn’t affect communications of the others. MELSEC I/O Link Module Input Specifications Model Name AJ55TB3-4D AJ55TB3-8D AJ55TB3-16D AJ55TB32-4DT AJ55TB32-8DT AJ55TB32-16DT AJ55TB32-4DR AJ55TB32-8DR AJ55TB32-16DR Type DC input Sink/Source DC input Sink DC input Sink/Source No. of Points 4 8 16 2 4 8 2 4 8 Rated Rated Voltage Current 24VDC 7mA Operation Voltage (V) ON OFF 14 6 Response Time (ms) ON OFF 10 10 Connection Type Points Per Common No. of Stations Terminal block 4 8 16 2 4 8 2 4 8 1 2 4 1 1 2 1 1 2 MELSEC I/O Link Module Output Specifications Model Name AJ55TB2-4T AJ55TB2-8T AJ55TB2-16T AJ55TB2-4R AJ55TB2-8R AJ55TB2-16R AJ55TB32-4DT AJ55TB32-8DT AJ55TB32-16DT AJ55TB32-4DR AJ55TB32-8DR AJ55TB32-16DR Type Transistor Sink Relay Transistor Sink Relay No. of Points 4 8 16 4 8 16 2 4 8 2 4 8 Rated Voltage Rated Current 12/24 VDC 0.5A/pt, 2A/com 0.5A/pt, 4A/com 0.5A/pt, 8A/com 2 2 24 VDC 240 VAC 2A/pt, 8A/com 10 12 12/24 VDC 24 VDC 240 VAC Response Time (ms) ON OFF 0.5A/pt, 1A/com 0.5A/pt, 2A/com 0.5A/pt, 4A/com 2A/pt, 4A/com 2A/pt, 8A/com 2 2 10 12 Connection Type Points Per Common Terminal block 4 8 16 4 8 16 2 4 8 2 4 8 Notes: 1. AJ55TB32-modules are input and output combination modules. 2. AJ55TB32-occupies only one station number for 4 point inputs and 4 point outputs. 3. See page 418 for dimensional information. Required Manuals Model Number Description Contents IB(NA)66574 MELSEC I/O Link Remote I/O System Master Module type AJ51T64/A1SJ51T64 Covers all AJ55TBxx-xxx I/O blocks Note: Many of these manuals are available by free download from our website, www.meau.com 416 Surge Absorber Zener diode None Zener diode None No. of Stations 1 2 4 1 2 4 1 1 2 1 1 2 Sold by AA Electric 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com I/O points on the remote I/O modules are kept small so that just the necessary number of I/O signals are distributed to locations where control devices are located. In addition, no terminal resistance requirement and the T shape branch feature gives maximum flexibility of configuration and layout. PROFIBUS-DP and I/O Link I/O Module Dimensions Sold by AA Electric 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com Profibus-DP AJ95 I/O Modules Profibus-DP MT Modules Digital I/O and MT-4DA Modules MT-DP12 Bus Interface Profibus-DP MT Modules Analog I/O Modules MT-LE Module Mitsubishi Electric Automation | Distributed I/O 417 Profibus AJ95FPBA2-16TE Sold by AA Electric 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com n DISTRIBUTED I/O Profibus AJ95FPBA4-16DE Profibus AJ95FPBA42-16DTE n I/O Link Modules Model AJ55TB-4 AJ55TB-8 AJ55TB-16 418 X (m) 82 114 177 X (in) 3.23 4.49 6.97