Download PKG_ML_095 Su Kam LI UPS 600VA
Transcript
PKG-ML-095 USER'S MANUAL (IFU) PURE SINE WAVE LI UPS 600VA Salient features Micro Controller based PWM technology using MOSFETs. Digital flash memory. Software controlled Auto Self - Test. A convenient no load shutdown at battery mode. Pure Sine wave output. Change over with Phase synchronisation. An extra wide input voltage range Inbuilt SMPS based charger with automatic power factor correction. Cold start at full load. Software controlled double protection for Overload and short circuit. RS- 232 interface for auto shutdown. GLOBAL CERTIFICATIONS: ISO 9001:2000 ISO 14001:2004 R&D Recognised MINISTRY OF SCIENCE & TECHNOLOGY GOVERNMENT OF INDIA Before connecting, operating, or adjusting this unit, please read this instruction booklet carefully . Customer Care : +91 124 4170561-566 1. Introduction 1.1 1.2 1.3 1.4 1.5 2. Overview................................................................. 2 Panel's Explanation................................................... 3 LED Indications....................................................... 3 Smart AVR............................................................... 4 Safety Instructions....................................................4 Installation and operation 2.1 2.2 2.3 3. Contents Installation............................................................... 5 Operation.................................................................5-6 Storage Instructions..................................................6 Communication Interface 3.1 3.2 DB9 Communication Port..........................................7 UPS Monitoring Software..........................................8-9 "Info Disc Manager" 4. Trouble Shooting 5. Technical Specifications 5.1 6. Sine Wave LI UPS 10 Sine Wave LI UPS...............................................11-12 Warranty Card 13-14 Contents REV. 05-02-08 (1) Sine Wave LI UPS 1. Introduction 1.1 Overview The Su-Kam Sine Wave UPS is an advanced high performance line interactive Uninterruptible Power System (UPS) designed to protect your computer and other computerized equipment from utility line failures, disturbances, frequency deviations, spikes and surges. In the event of utility power failure, the UPS will rapidly transfer loads to an alternative power source, which derives power from the battery placed inside the UPS. The UPS has inbuilt SMPS based charger with automatic power factor correction. Introduction (2) REV. 05-02-08 Sine Wave LI UPS 1.2 Panel's Explanation Front Panel 1.3 LED Indications Green Color Continuous Mode Mains ON Charging ON Output ON Multi-Color LED Blinking Mode Fast Slow Mains ON Charging ON Output OFF Red Color Continuous Mode SINE WAVE LI UPS Backup ON Blinking Mode Fast Slow Low Battery Overload Back Panel COM. PORT 5 1. OUTPUT 3 2 FUSE 3 Core 6A Input Plug (Mains Input). 2. 2 6A AC Output Socket (Universal). 3. 6A D-Type AC Output Socket. 4. T2.5A/250V (Slow Blow) fuse. 5. RS-232 Communication Port. 4 AC INPUT The UPS will turn OFF permanently in case of low battery, overload, short circuit protection and also in case of no load shut down. There will be no LED indication in such a case. REV. 05-02-08 Panel’s Expl. & Led and AlarmIndication (3) Alarm Sine Wave LI UPS 1.4 Smart–AVR The UPS automatically regulates output voltages within the normal range, both in low utility voltage and high utility voltage conditions. The UPS is equipped with cold start function to enable the user to start it without utility power. 1.5 Safety Instructions The UPS contains voltages which are potentially hazardous. The UPS has its own internal energy source (battery). The output receptacles may be live even when the UPS is not connected to an AC supply. All repairs should be performed by qualified service personnel . Safe and continuous operation of the UPS depends partially on the care taken by user. Please observe the following precautions: Do not disassemble the UPS. Connect the UPS to a two pole, three-wire (Line, Neutral & Earth) mains with receptacle. Connection with any other type of receptacle may result in a shock hazard and may violate local electrical codes. Do not allow water or any foreign object to get inside the UPS and do not put objects containing liquid on or near the UPS. Keep UPS away from fire or heating sources. The Power socket should be installed near the equipment and be easily accessible. To isolate from AC input, disconnect the plug of the power cord of the system . The battery will discharge naturally. If it is charged periodically, Its life will be prolonged. It will be damaged if it is not used for a long Period. This won't be covered in our Warranty. Smart AVR & Safety Instructions (4) REV. 05-02-08 Sine Wave LI UPS 2. Installation and Operation 2.1 Installation. Inspect the Carton Box for any damage that may have occurred while in transit. Immediately notify the carrier and place of purchase if there is any damage . Retain the package for future use. Connect the power cord to a verified grounded 3-wire receptacle. For connecting your equipment to the UPS and to ensure that your computer equipment will be protected during a utility failure, it is important to make sure that the maximum power need of the equipment is not over the rated capacity of the UPS 2.2 Operation When the Power Cord is connected with normal utility power, UPS will turn ON automatically and goes through the procedure of self test. If test results are O.K., the LED will blink in green color indicating that the mains is available and UPS starts battery charging. UPS output will be available only when front power switch is pressed for few seconds (LED glows continuously when O/P is ON) REV. 05-02-08 Installation & Operation (5) Sine Wave LI UPS Press the front power switch again for few seconds, the UPS will turn OFF the power to equipment (O/P OFF) . if the AC Power Cord is still connected, LED will blink in green color indicating that the battery is charging. To turn OFF the power completely, please pull out the power Cord. To test backup function during power failure, press the front power switch for few seconds. The UPS will work in backup mode with buzzer beeps. In this mode the LED glows continuously in Red color. To turn OFF the UPS, Please press the front Power Switch again for few seconds. The UPS will automatically turn OFF the output power during backup mode when power consumption is lower than 6% of full specified load. If overload condition occurs, the buzzer will beep rapidly. The LED will also blink rapidly in red color indicating the condition of overload. Please proceed to unplug the least critical equipment. In case of low battery, the LED will blink slowly. 2.3 Storage Instructions For extended storage in moderate climates, the batteries must be charged for 8 hours every 2 months by plugging the power cord into the wall receptacle. Repeat it every month in high temperature locations. Storage Instructions (6) REV. 05-02-08 Sine Wave LI UPS 3.Commnication Interface 3.1 DB 9 Communication Port Located at the rear side of the unit, the com-connector is a plug in interfacing port (9-pin sub. D-female) which enables advanced communication between the UPS and Computer (interface kit required). The diagrammatic interface (communication cable) of UPS with computer: 11 2 3 4 11 6 6 66 7 7 7 8 8 9 9 8 7 8 22 33 4 4 5 9 Pin Male UPS Side 5 9 Pin Female PC Side COMMUNICATION CABLE REV. 05-02-08 Communication Port (7) Sine Wave LI UPS 3.2 Info Disc Manager The Su-Kam UPS monitoring software "Info Disc Manager Version 1309-07 S" is compatible with almost all popularly used operating systems as Windows 95, 98, NT, 2000, Millennium and XP to name a few with best reliability. An easy to install auto run software CD and DB-9 Communication connector cable is to be connected to facilitate convenient interfacing of PC with UPS. On first start, the software shows a registration form it is mandatory to fill this for proper functioning of the software. Once registration is completed, the software will ask user to select the communication port for communication with the UPS. The port once selected will become the default and the software will start automatically on that port every time. In case user wants to change the port which is once made default then he must change it in less than 30 seconds when the port form pops up after the beginning of the software. Once installed it will start automatically after completion of operating system booting and continuously monitor the system by showing the icon in the status bar of desktop. When the battery low signal appears, the software sends the system to shutdown thus preventing damage caused by abrupt shutdown. It pops up message of power failure for the signal received. It logs data of Power failure, Normal mode, Battery low to show the log records of last three states of UPS. Info Disc Manager REV. 05-02-08 (8) Sine Wave LI UPS The Graphical User Interface of software has following display consoleFlashing red or green communication icon in status bar of software to show ongoing communication status. Mains status indicator. Power failure status indicator. Low battery status indicator. UPS power status last three log records. This is a complete solution designed to prevent hard-disk crashes and to take care of sophisticated compute components. It completely eradicates the chances of abrupt shutdown thus providing total care, security and convenience. 13 14 UPS Status During Normal Mains Mode REV. 05-02-08 Info Disc Manager (9) Sine Wave LI UPS 4.Trouble Shooting The trouble shooting chart covers most of the difficulties that you may encounter under normal working conditions. Should the UPS fails to operate properly, please check the following before calling for service: 1. 2. Is the UPS plugged into an incorrect wall receptacle? Is AC Input voltage / frequency out of range? When calling for service, please offer the following information: 1. 2. 3. Model No. and Serial No. Date of occurrence of the problem. Full description of problem, including condition, environment which it is installed, devices connected to the UPS. Problem No light, No Alarm switch UPS switched off Automatically or RED buzzer beeps. UPS switched off UPS will not switch to battery mode. Trouble Shooting (10) Possible Cause 1. AC fuse Blown 2.Power cord is loose 3. Mains switch is not "ON" 4. System failure 1. Overload connected at UPS’s outlet 2. Short circuit on Inverter 3. Battery Low Trouble Shooting Replace AC fuse of actual rating Connect AC power cord to wall rec eptacle Turn On mains switch Contact your dealer Reduce Load 1. Mains failure, battery discharged, battery depleted. Check load & output side properly for shorting Battery is low due to excessive load or battery is consumed. Wait, until mains returns. Wait, until mains returns. Allow the UPS to recharge the battery for at least 6 hours 4. System failure Contact your dealer REV. 05-02-08 Sine Wave LI UPS 5. Technical Specifications MODEL CAPACITY SU600WB 600VA/12V INPUT PARAMETERS Input Supply 1 Phase, 3 Wire 145VAC-295VAC ± 5V Voltage range Frequency Range Same as Input OUTPUT PARAMETERS (MAINS MODE) Voltage range 200VAC-255VAC ± 5V Waveform Same as Input Frequency Range Same as Input OUTPUT PARAMETERS (INVERTER MODE) Voltage Regulation 200VAC-245VAC Frequency Regulation 50 ± 0.2Hz Output Waveform Sine Wave Transfer Time (Typical) Overload Handling Capacity 8 msec 105% for 3 mins, 160% for 5 secs BATTERY PARAMETERS Cell / Battery Type 12V/7.2AH Battery Voltage (Nominal) 12V Battery Charging Current 1A ± 0.1A USER INTERFACE Communication Port Operating System RS-232 Windows 95/98/NT/2000/XP/2003 Server PROTECTION Over/Under Voltage Switch to battery O/P when mains is over/under the specified range Overload/Short Ckt Fuse & current limited for battery mode, Fuse protection for mains mode Low/High Battery Surge Protection Battery deep discharge / over charge protected Yes Note : Specifications subject to change without prior notice. REV. 05-02-08 Technical Info Disc Specifications Manager (9) (11) Sine Wave LI UPS MODEL CAPACITY SU600WB 600VA/12V ENVIRONMENTAL PARAMETERS Operating Temperature Acoustic Noise (at 1 mts) Relative Humidity 0-45°C <50dB 0-90% non-condensing OTHERS Indications & Alarm Protection Class Dimensions W X D X H (in mm) Weights (Kg) Technical Specifications (12) LED Indications & Alarm IP20 112 x 345 x 150 6.5 Note : Specifications subject to change without prior notice. REV. 05-02-08 Sine Wave LI UPS Model No. :--------------------------------------------- Serial No. :--------------------------------------------- Name of Purchaser :--------------------------------------------Address :--------------------------------------------- Date of Purchase :--------------------------------------------- Dealer's Name :--------------------------------------------- DEALER STAMP REV. 05-02-08 Warranty (13) Sine Wave LI UPS TERMS AND CONDITIONS OF WARRANTY Su-Kam warrant to the original purchaser provided the product is still in possession of and used by the original purchaser from the date of purchase. The warranty stands on all parts (except LED's, switches and external body) for UPS will be for a period of 12 months. The warranty will be automatically terminated on the expiry of the warranty period, even in case of the UPS no t being in use in the specified period. This warranty is valid only if it is duly signed by the authorized dealer. The warranty will be invalidated if defects arising in company's opinion by reasons of accident, abuse, misuse, neglect, improper installation (if not undertaken by the company or its representative), fire, flood, or other act of GOD and any other natural calamities and any other unauthorized repairs done or carried out will have to be borne by the purchaser. The problem of fuse blown will not be included in the warranty of the product. The services given for the same will be paid service. The company is in no way liable for any loss or injury or damage caused to life or property or death and disability caused to any form of life for any reason whatsoever. The warranty will not apply if the original seals are found broken or tampered with. Free service under the terms of warranty will be provided only by authorized representatives/dealers of the company. The company expressly denies the right of any person to incur or assure for it any other liability or obligation in connection with the sale of UPS. Claims if any, to this warranty shall be made only before courts having jurisdiction in New Delhi. Please send your query or Complaint to [email protected] Warranty REV. 05-02-08 (14) SU-KAM OFFICES ADDRESSES BANGALORE H.No.449, Ground Floor, 7 th Cross, 6th Main, MICO Layout, BTM II Stage, Bangalore 560076 Karnataka Tel.: 080-32961610, 41506332 E-mail : [email protected] CHATTISGARH Flat No. 1, Govind Kunj, Civil Line, Near Jabal Fabricator, Raipur-492001 Chattisgarh Tel.: 0771-3209092, 09981541645 DEHRADUN Vedwalia, Ward No-15, Bhusa Store, Near Shiv Mandir, Sharanpur Road, Village & P.O. Majra, Deharadun-248001 Uttarakhand Tel: 09999399605 Email: [email protected] BHUBANESHWAR 389, Bomikhal, Cuttack Puri Road, Bhubaneshwar- 751006 Orissa Tel.: 0674-2585120, 09937014979 CHENNAI Old No. 87 & New No-23, Valluvar Salai, Arumbakkam Chennai- 600106 Tel: 044-32984497, 09952966135, 09940634442 E-mail: [email protected] DELHI WZ-1401/02, Nangal Raya, Near Lajwanti Garden, New Delhi-110046 Tel: 011-32560709, 32533361, 09971497598 Email: [email protected] CHANDIGARH SCO-215-217, 3rd Floor, Office No. 302, Sector-34 A, Chandigarh-160019 Tel.: 0172-4648509, 09878694005 E-mail: [email protected] COCHIN Door No-27/77; Plot No-188, 8th Cross Road Girinagar, Cochin, Ernakulam-682020, Kerala Tel: 0484-2316141, 09995882575 Fax: 0484-2316141 E-mail: [email protected] GHAZIABAD 13/7, Site No. 3, Meerut Road, Industrial Area-3, Near Uttam Toyota, Ghaziabad-201001 Uttar Pradesh Tel: +91-120-3239910, 9810434566, 9997797852 E-mail: [email protected] VADODARA 203 Padmavati Complex, Shrenik Park Char Rasta, BPC Road, Akota, Vadodara-390020 Tel: 0265-3206250, 09974555280 E-mail: [email protected] JAIPUR 206, Adarsh Plaza Khasa, Kothi Crossing, SJS Highway, Jaipur Rajasthan Tel: 0141-4016625, 09878694005 E-mail: [email protected] KOLKATA 8th Floor, Room No-14, Shanti Niketan Building, 8 Camac Street, Kolkata-17, West Bengal Tel: 033-32963664, 09903114026 Email: [email protected] PATNA D-3, Jula Niketan, West Boring Canal Road, Anand Puri, Patna-800001, Bihar Tel: 0612-3200776, 09934015347 Email: [email protected] HYDERABAD INDORE Plot No. 81, Syndicate Bank Colony West Marredpally, Secunderabad-500 026 Andhra Pradesh Tel.: +91-40-27717628, 09959778881 E-mail: [email protected] F-47, MIG Colony, Near Criestean Eminent School, Indore 452001 Madhya Pradesh Tel: 0731-3204887, 09993590245 E-mail: [email protected] JAMMU Malik Market, Channi Rama, Bye Pass Road, Jammu - 180004 J&K Tel: +91 9906908470, 9906905009 E-mail: [email protected] KANPUR 403, 404 Gopala Chambar 4th Floor, Parade, Kanpur Tel: 09956295691 Email: [email protected] MUMBAI NAGPUR 15, RNA Arcade, 1st Floor, Cross Lane No. 3, Lokhandwala Complex, Andheri (West), Mumbai - 400058 Email: [email protected] Tel: 022-40166900 Fax: 022-40166905 R-2, Near 8 Rasta Chowk, Laxmi Nagar, Nagpur-440022 Tel: 0712-3297252, 09975496264 Email: [email protected] PUNE 940, 2nd Floor, Synagogue Street, Near Railway Reservation Centre Camp, Pune-1, Maharashtra Tel: 020-32303900, 30523788, 09975496268 Email: [email protected] SU-KAM POWER SYSTEMS LTD. FACTORY: 64, DIC INDUSTRIAL AREA, BADDI, DISTT. SOLAN (H.P) INDIA CORP OFF.: 54, SECTOR-37,PH-VI,DISTT. GURGAON (HARYANA) INDIA REGD.OFF.: WZ-1401/2, NANGAL RAYA , NEW DELHI-46 RANCHI 74/D, Plot No. 1, Park Road 3, Ashok Nagar, Ranchi-834002 Jharkhand Tel: 0651-3203277, 09934015338 Email: [email protected] PKG-ML-095