Download User manual - Heatrae Sadia
Transcript
I thoCVEECO2RFT Installer/Usermanual 0711/ED 211.0599 CVE ECO-fan ENG.indd 1 25-07-11 16:19 Safety thepowersupplyandnolongeruseit. - Donotoperatetheapplianceinthepresenceof Warning inflammablesubstancesorvapours(alcohols, - Donotusethisapplianceforfunctionsotherthanthose insecticides,petrol,etc). describedinthebooklet Caution - Afterremovingtheappliancefromitspackaging, ensurethatitiscompleteandundamaged.Indoubt Thefollowinggeneralinstructionsareimportant: contactIthoUKLtd.Donotleavethepackagingwithin - Followthesafetyinstructionstopreventfandamage reachofchildrenortheinfirm. andpersonalinjuries. - Certainfundamentalrulesmustbeobservedwhen - Maintenanceinstructionsmustbefollowedtoprevent usinganyelectricalappliance,includinga)nevertouch damageand/orexcessivewearandtear. applianceswithwetordamphands;b)nevertouch - Thespecificationsinthismanualmaynotbemodified. applianceswhilebarefoot;c)donotallowchildrento - Thefansmaynotbemodified. usetheappliancewithoutsupervision;d)supervise - Themotormoduleisonlysuitablefora230V50Hz infirmpersonswhenusingtheappliance. A.C.system. - Storetheapplianceoutofthereachofchildren - Donotexposetheappliancetotheweather(rain, andinfirmpersonsifyoudecidetodisconnectitfrom sun,etc). 2 211.0599 CVE ECO-fan ENG.indd 2 25-07-11 16:19 - Donotplaceobjectsontopoftheappliance. heaters,roomheatersetc.,norshoulditdischargeinto - Regularlyinspecttheapplianceforvisibledefects. thefluesofanysuchappliances. Ifanyfaultsarefound,contactIthoUKLtd. - Ensurethattheappliancedischargesintoasingle immediately. duct(dedicatedtothisproduct)whichisroutedtothe - Theappliancemustonlybeinstalledbyaprofessionally outside. qualifiedperson. - Theairtobeextractedfromthedwellingmustbe - Ensurethattheelectricalsystemtowhichthe clean(i.e.freeofgrease,soot,chemicalandcorrosive applianceisconnectedcomplieswithapplicable agents,explosiveorflammablemixtures). standards. - Keeptheapplianceintakeandoutletvalves/grillesfree - Useamulti-polarswitchwithaminimumcontactgap toensureoptimumairflowatalltimes. of3mmtoinstalltheappliance. Electroniccomponents - Switchoftheapplianceatthemainswitch:a)ifthe appliancedoesnotfunctioncorrectly;b)before TheCVEECO2RFTfancontainspartswhichmaybelive. cleaningtheoutsideoftheappliance;c)iftheappliance Consultaprofessionallyqualifiedinstallerintheeventof isnottobeusedforanylengthoftime. anallegedfault.Allrepairsandmaintenanceworkshould - Becarefultoavoiddamagingtheelectriccircuit. becarriedoutbyaprofessionallyqualifiedinstaller. - Donotusetheappliancetocontrolactivationofwater 3 211.0599 CVE ECO-fan ENG.indd 3 Itho | cve eco 2 rft 25-07-11 16:19 Maintenance Sharpedgesoftheducts Theventilationunitshouldbeinspectedregularlyfor Thevalvesinyourhomeshouldalsobecleanedregularly. contamination.Electricallydischargetheunitbefore Thesecanberemovedfromthewallorceiling. carryingoutanyworkonit.Firstisolatetheunitfrom Bewareofprotrudingductsections.Thesecanbevery themainssupplyandmakesurethattheunitisnot sharp. re-connectedtothesupplysocketbyyourselforanyone Replacingthevalves elsebeforeyouhavecompletedthework. Thevalvesshouldalwaysbeplacedbackintheiroriginal Rotatingparts locations.Donotturnthevalveduringthecleaning TheCVEECO2RFTfancontainsrotatingmechanical process;makesuretomarkthesettingbeforecleaning parts.Thesepartswillkeeponturningforafewseconds thevalve.Ifthevalvesareswitchedorsetdifferently, afterdisconnectingtheunitfromthesupply.Forthis theventilationvolumeswillnolongerbecorrectandthe reasonwaitatleast10secondsafterisolatingtheproduct ventilationsystemwillnotworkoptimally.Thebathroom beforeopeningtheunit.Thefanwillnotbemovingafter maythenremainhumidfortoolong,yourtoiletmaybe these10secondshaveelapsed. verycooloryourkitchenmaysmellmouldy. 4 211.0599 CVE ECO-fan ENG.indd 4 25-07-11 16:19 Contents 1. Introduction 2. Whyisventilationimportant? 6 9 3. Individualventilationsystem 11 4. thecentralventilationunitCVEECo2RFt 13 5. thecomponentsoftheCVEECo2RFt 14 6. howtooperatetheunit 17 7. Maintenanceandwarranty 19 8. Informationfortheinstaller 21 9. Manufacturer’sstatement 24 10. ECDeclarationofConformity 26 Subjecttochangeswithoutnotice. Norightscanbederivedfromthisusermanual. 5 211.0599 CVE ECO-fan ENG.indd 5 Itho | cve eco 2 rft 25-07-11 16:19 1 Introduction Interiorcomfortandenergyefficiencyarebecoming CompliancewithBuildingRegulations increasinglyimportantconsiderationsinbuilding.More The2010EditionoftheU.K.BuildingRegulationsApproved andmoreequipmentisbeingdevelopedtocontrolthe DocumentF1:MeansofVentilation(applicableinEngland climatewithinthehomewhilemeetingtherequirements andWales)details4clearlydefinedsystemsofventilation forcomfortandenergyefficiency.Oneofthesedevicesis todwellings.System3–Continuousmechanicalextract theIthoUKLtdCVEECO2RFT,anextractorunitwhichis (MEV)iscompliedwithbythenewCVEECO2RFTultra- theheartofthewholehouseventilationsystem. highefficiencywholehouseextractventilationsystem. ACVEECO2RFThasbeeninstalledinyourhome.Inthis System3–Continuousmechanicalextractrequiresa usermanualyouwillfindinformationaboutthenecessity “minimumhighrate”ineachwetroomtobeachieved ofgoodventilationandhowyourCVEECO2RFTworks. (Kitchens13l/sandbothutilitiesandbathrooms8l/s- Additionally,weexplainhowtooperateandmaintain sanitaryonly6l/s). theunit. The“minimumlowrate”iscalculatedbytakingthe Itisimportantthatyoureadthisusermanualthoroughly numberofbedroomsinthedwellingandapplyingthel/s beforeusingtheventilationsysteminyourhome.Itisalso valuefromTable1.1b.Inadditiontherateshouldbeno agoodideatokeepthemanualnearyourCVEECO2RFT lessthan0.3l/sperm2ofinternalfloorarea(allstorey’s) unit. 6 211.0599 CVE ECO-fan ENG.indd 6 25-07-11 16:19 plusforeachadditionaloccupantoverandabovethe ThecurrentBuilding(Scotland)Regulationsrefersto anticipatedtwoforthefirstbedroomandoneforeachof continuouslyoperatingmechanicalextractventilationin theothersafurther4l/smustbeaddedtotheextract accordancewiththeguidanceinBRE(BuildingResearch rate.Thesystemprovidesquiet,uninterruptedextract Establishment)Digest398,apaperbasedontheformer ventilationfromthedwelling,removingwarmstaleair governmentdepartment’s(andnowprivatecompany)own viaallofthe“wet”rooms,creatingapermanentairpath testsandrecommendations,specifically0.5airchanges throughthepropertyfromthe“dry”habitablerooms. perhourthroughouttheproperty.TheCVEECO2RFT compliesfullywiththerecommendationscontainedwithin Airisusuallydrawnintothepropertythroughbackground thisdocument. ventilatorslocatedinthebuildingfacades.Howeverifthe systemisbeinginstalledtosolveanincomingairborne WiththeGovernmentsactivelyencouragingenergysaving noiseissue,backgroundventilatorsmaybeomitted andatargetforallnewhomestobe‘carbonzero’by2016, (subjecttotheprovenairtightnessofthedwelling).There theCVEECO2RFThasbeendesigned‘futureproof’.The isaboostfacilityonthefanwhichenablestheextract ‘CodeforSustainableHomes’wasupdatedinOctober2010 ratesfromallwetroomstobeincreasedtocounter toreflectthechangestothe2010BuildingRegulations. increasedpollutantscausedbycookingorbathing Level4nowrequiresafurther25%reductioninCO2 activities. emissions. 7 211.0599 CVE ECO-fan ENG.indd 7 Itho | cve eco 2 rft 25-07-11 16:19 Toachievethethreehighestlevelsofreductionof carbonemissions,theairleakageofthedwellingmust beimprovedsosignificantlythatcontinuousventilation becomestheonlyappropriatemethod.Inaddition,it mustbedemonstratedthattheventilationsystemitself mustbeenergyefficient.TheCVEECO2RFTwithits lowenergyD.C.motorandinnovativeimpeller,has beenindependentlytestedbytheBuildingResearch Establishment(BRE)totheappropriateSAP1)AppendixQ testmethodologyandisthereforeAppendixQeligible 1)TheGovernmentsStandardAssessmentProcedure (SAP)isamethodassessingtheenergyperformanceof dwellingsandSAPAppendixQprovidesanallowancefor thebenefitsofenergy-savingappliances;productsmaybe independentlyassessedandtheresultsuploadedtothe SAPwebsite. 8 211.0599 CVE ECO-fan ENG.indd 8 25-07-11 16:19 2 Whyisventilationimportant? Ventilationisnecessary Ventilationisabsolutelynecessaryinanair-tighthome Inthepastpeoplebuilthouseswhichwerenotair-tight, topreventproblemsrelatedtohumidity,mouldandthe whichleakedair,forexample,attheconnectionpoint healthoftheresidents. ofthewallandthefloororroof.Crackswerealways visiblearoundwindowsanddoors.Alltheseopenings Moisturecontentofthehome ensuredthatlargevolumesofairmovedinandoutofthe Incorrectuseoftheventilationsystembytheresident buildings.Whenthewindwasblowingthecompleteair incombinationwithtoday’swell-insulatedhomesgives contentofthehomewasrefreshedthreetofourtimesan humidityanopenfield.Themoisturecontentinthehomes hour.Thisensuredverygoodventilationofthehome,but increasesandcancausehealth,humidityandmould alotofenergywaslost. problems.Afamilyoffourpersonsproduces14to20litres ofmoistureperdayjustbybreathing,sleeping,cooking, Constructionmethodshavechanged.Floors,wallsand washing,dishwashing,bathing,wateringplants,etc. roofsare,whenpossible,constructedwithalayerof Manyproducts,suchastextile,carpets,parquet, insulation.Theinsulationensuresthattherearenearly newspapersandcigarettes,containsubstancesthatharm nocracksandtheairtightnessisincreased.Itisa thehealthoftheresidents.Allthemoisturesuchaswater misconceptiontothinkthatthereisstillenoughventilation vapourandaromaticsubstancesshouldberemovedfrom inahomewithoutsometypeofventilationsystem. thehomes. 9 211.0599 CVE ECO-fan ENG.indd 9 Itho | cve eco 2 rft 25-07-11 16:19 thecorrectuseoftheventilationsystemis Researchhasproventhatfightingmoistureinhomes important greatlycontributestothedecreaseofallergicreactions Ventilationrequiresenergy.Thecorrectuseofthe ofpeoplewithanairwaydisorder.Thecorrectuseand ventilationsystemcanlimitenergylossasmuchas maintenanceofyourventilationsystemmakesthis possible. possible! Anindividualventilationsystemhasbeenbuiltintoyour YourhomehasanIthosystemwhichwassuppliedby home.Thisself-containedsystemallowsyoutoadjust IthoUKLtd.Thissystemcancontributeextensivelytoa yourindividualventilationsystem.Thesystemconsistsof healthyinteriorclimateandanoptimumcomfortlevel. thefollowingparts: Anotheradvantageisthattheelectricitycostsarelower thanotherventilationsystems.Theventilationsystem - CVEECO2RFTextractorunit can,however,onlyfunctioncorrectlywhenusedand - Valves maintainedinaresponsiblemanner.Somedata:5to - Switchtoselectloworhighrateventilation 20%ofpeoplehaveanairwaydisorder.Thenumberof (CVEECO2RFT)or, housedustmitehasincreasedahundredfoldinthepast - OneormoreRFTswitcheswiththreespeedsettings 25years.ThenumberofpeoplesufferingfromChronic (CVEECO2RFT) Non-SpecificLungDiseasehasdoubledinthelast15years. 10 211.0599 CVE ECO-fan ENG.indd 10 25-07-11 16:19 3 Individualventilationsystem howtheindividualventilationsystemworks Theextractorunitventilatesseveralroomsinthehome throughductsfittedinthekitchen,thebathroom,theWC andallother‘wetrooms’.Theseareconnectedtothe centralextractorfansystem.Toensurethereisagood distributionofair,valvesarefittedtotheopeningsof theventilationductsintheroomstobeventilated.Airis extractedfromtheroomsthroughthesevalves,while freshairfromoutsideentersthehomethroughopenings, suchasgrilles,inthewallsandwindowsoflivingrooms andbedrooms. 11 211.0599 CVE ECO-fan ENG.indd 11 Itho | cve eco 2 rft 25-07-11 16:19 211.0599 CVE ECO-fan ENG.indd 12 25-07-11 16:19 4 theCVEECo2RFtcentral-ventilationunit TheCVEECO2RFTwasdevelopedtomaintaina Innovativetechnology comfortableclimatewithinhomebymeansofanenergy- Anumberofinnovativetechnologieshavebeenusedin efficientandconvenienttechnology. thedevelopmentoftheCVEECO2RFT.Forexample, Theenergyefficiencycomesfromtheapplicationof theunithasasingleprintedcircuitboardforboththe directcurrentmotors.TheCVEECO2RFThastheadded regulatingandthecontrolelectronics.Theconstructionof convenienceofradiofrequency(RFT)remotecontrol. thefanisalsonew.Theairisnowcirculatedthroughthe fanbycone-shapedblades.Thisresultsinmoreefficient Energy-efficientdirectcurrentmotor propulsionoftheairandthustogreaterenergyefficiency. Theenergyefficiencydemandsofhomesandbuilding practisesarebecomingincreasingstringent.Forthis reason,theIthoCVEECO2RFTisequippedwithdirect currentmotors.Thesemaketheunitveryenergyefficient anddeliversignificantsavingsonelectricitycosts(up to80%). 13 211.0599 CVE ECO-fan ENG.indd 13 Itho | cve eco 2 rft 25-07-11 16:19 5 thecomponentsoftheCVEECo2RFt housing ThehousingoftheCVEECO2RFTisconstructedtoallow easyreplacementoftheparts,whichmakesmaintenance andcleaningverysimple.Theunitcanbemountedonthe wallorceilingusingthemountingbracketsprovided. Theunithasfiveairconnections.Therightportontheunit (1)istheoutletfunnelforairextractedandblownoutside. Theotherfourports(2)arefortheremovaloftheairfrom thehome.Theyarelocatedasfollows: TheCVEECO2RFTismodularandhasseveraldifferent components.Thismakesthesystemmorereliable - Onthetopleftoftheunit. technicallyandsimplertoservice.Theunitismadeof - Ontherightsideoftheunit. polypropylene(atypeofplastic).Thismaterialhasalong - Ontheleftsideoftheunit. lifeandcanbecleanedwithadampcloth. - Onthebottomoftheunit. 14 211.0599 CVE ECO-fan ENG.indd 14 25-07-11 16:19 2 1 Frontcover TopermitinstallationoftheRFTsetreceiverorother work,suchasmaintenance,theunit’sfrontcovercan beremovedwithascrewdriver.Insertthescrewdriver horizontallyinthespaceprovidedonthetopleftandpress openthecover.Youcanthenremovethecoverbyhand. 2 2 Note:Disconnecttheunitfromthemainssupplybefore removingthefrontcover. 2 Thebluecoversontheunitcloseofftheunusedairinlets topreventleakageofairandensurethatmaximum capacityisused. 15 211.0599 CVE ECO-fan ENG.indd 15 Itho | cve eco 2 rft 25-07-11 16:19 Servicemodule Electronics Ifthereisafaultwiththemotororelectronics,the Theelectronicsarealsoanimportantpartoftheunit. techniciancaneasilyfixtheunitbyreplacingtheservice Whenyouchangesettingswiththeswitch,theelectronics module. carryoutyourcommand.Themotorissettothe Thewarrantyontheservicemoduleisfortwoyearsfrom desirednumberofrpmstoensuresufficientventilation. theinstallationdate.Formoreinformationaboutthe Theelectronicsconsistofabasicprintedcircuitboard termsandconditionsofthewarranty,seechapter7. withanintegratedRFTreceiverwhitchwillpermitthe RFTremotecontrolswitchestooperatetheswitches. Motor-drivenfan theusershouldnottouchanyelectronicparts Themotor-drivenfanformstheheartoftheventilation –theymaybeelectricallylive. unitandhasbeenspeciallydesignedforCVEECO2RFT. Duringthedevelopmentofthedirectcurrentmotor, specialattentionwaspaidtolownoiselevels,high efficiencyandahighvolumeofairmoved.Thiscontributes toahealthyandcomfortableinteriorclimateinyourhome andloweroperatingcosts. 16 211.0599 CVE ECO-fan ENG.indd 16 25-07-11 16:19 6 howtooperatetheunit IndividualCVEECO2RFTventilationsystemscanbe Theswitchalsohasatimer.Theventilationunitcan controlledeitherbyathreespeedhardwiredswitchor beswitchedtohighmodeforapredeterminedtime bywirelessthreespeedRFT. bypressingthetimerbutton.Thetimerautomatically switchestheventilationunittolowmodeafterthetime Radiofrequency(RF)operationswitch haselapsed. TheRFT(radiofrequency)operationswitch(transmitter) canbeusedasa3-positionmodeswitchwithtimer Thelengthoftimesetforthetimerisdeterminedbythe featurefortheCVEECO2RFTventilationunit.This user.Pressthetimerbuttononcetosettheventilation operationswitchcanbeusedtosettheventilationunit unittohighmodefor10minutes.Pressthetimer tooneofthethreeventilationmodes(capacities): buttontwicetosettheventilationunittohighmodefor Themodesare: 20minutes.Pressthetimerbuttonthreetimestoset - Mode1-Lowmode. theventilationunittohighmodefor30minutes. - Mode2-Mediummode. Iftheoperationswitchisusedbychoosingmode1,2or3 - Mode3-Highmode. whilethetimerisinoperation,thetimerisswitchedoff Thelowmodeisusedatnight,themediummodeduring andtheventilationunitoperatesinthechosenmode. thedaywhentherearepeopleathomeandthehighmode whencooking,showeringorbathing. 17 211.0599 CVE ECO-fan ENG.indd 17 Itho | cve eco 2 rft 25-07-11 16:19 hardwired3positionswitch &9((&25)7 1 0LGGOHVSHHG %RRVWVSHHG / & TheCVEECO2RFTcanbeoperatedusingthe3position SRVLWLRQVZLWFK +56 switchHRS-3.Steponeisusedatnight,steptwoduring thedaywhentherearepeopleathomeandstepthree whencooking,showeringorbathing. /1 9+] 18 211.0599 CVE ECO-fan ENG.indd 18 25-07-11 16:19 7 Maintenanceandwarranty Maintenance - Checkthatthebearingsdon’tmakeanynoise. TechnicalmaintenanceoftheCVEECO2RFTisnotneces- - Checkthatthefandoesn’tswingfromsidetoside. sary.However,theunitwillneedtobecleanedonceevery - Ifthefanissetinmotionbyhand,itshouldonlyrotate threetofouryearsdependingontheaccumulationofdust. afewtimesandthencometoastandstillwithafew Youcancheckyourselfwhethertheextractorunitisvery jolts. dirty,butitmustbecleanedbyaqualifiedtechnician. - Thisisacharacteristicofadirectcurrentfanandis Tocheckwhetheryourextractorunitisdirty,follow - Dependingontheoutcomeoftheinspection,thefan completelynormal. thesesteps: shouldbecleanedand/ormadereadyforuse. - Isolatetheunitfromthemainspowersupply. - Fitthebluesealingcoverstoclosetheinlets. - Removeoneormoreofthebluesealingcoverssothat - Reenergisethemainssupply. youcanseethefan. Valves - Inspectthefanfordustanddirt. Alittledustmakeshardlyanydifferencetothefan’s Thevalveshavetobecleanedregularlytoensurethe performance.Ifthelayerofdustanddirtismorethan constantandreliableoperationoftheventilationsystem 1mmthickontheinsideoftheblades,weadvisehaving andforyourownhealth.Makesurethatthesettingof thefancleaned. thesystem(airflow)isnotchangedwhenyoucleanthe - Checkthebearings.Youcandothisbyspinningthefan. valves.Thevalvecouldbeturnedbyaccidentandthis 19 211.0599 CVE ECO-fan ENG.indd 19 Itho | cve eco 2 rft 25-07-11 16:19 wouldmeanthattheopeningbecomeslargerorsmaller. Eachvalveshouldbeplacedbackinthesameduct openinginthesameroomfromwhichitwasremoved. Cleaningvalves Valveswithoutafiltercanberemovedfromtheduct opening.Thefoamring(ifapplicable)shouldberemoved beforecleaningthevalveinwarmwater(andwashingupliquid).Replacethevalveintheductopeningafter cleaning.Thevalveshouldalwaysbeplacedinthesame ductopeningitwasremovedfrom. MaintenanceofDucting Itisourrecommendationthattheductingconnected totheExtractTerminals(locatedinKitchens,Utilities, BathroomsandEn-suites)needstobeinspectedevery 3yearsandcleanedevery6years.Cleaningofthegrille andductingcanbecarriedoutwithadampcloth. 20 211.0599 CVE ECO-fan ENG.indd 20 25-07-11 16:19 8 Informationfortheinstaller Installation - Thefeedercableis1.5mlongandtheconnectionis - Theductsshouldbeofthecorrectdimensions - Fansandductinginorpassingthroughunheated - TheCVEECO2RFTcanbeusedinvarioustypesof locatedtowardsthetopoftheunit. homes,bothinnewbuildingaswellasrenovation projects.Theunitcanbeinstalledatdifferentplacesin (125mmdiameteror204X60rigid). thehome,forexample,inaloftspace,storeroomor cupboard. voidsorloftspacesshouldbeinsulatedtoreduce - Theextractorunitcanbeinstalledinallpositionsusing thepossibilityofcondensationforming. themountingeyesprovidedagainstawall,onthe ceilingandalsoonslopingsurface. Theunitcanbeconnectedinvariousways. - TheCVEECO2RFTshouldbeinstalledfollowingthe generalandlocalsafetyandinstallationregulations andtheinstructionsinthismanual: - TheCVEECO2RFTrequires230V50Hzmains - Amultipolarswitchmustbefittedwithaminimum voltage.Thetoleranceforthemainsvoltageis5%. contactgapof3mm. 21 211.0599 CVE ECO-fan ENG.indd 21 Itho | cve eco 2 rft 25-07-11 16:19 Settingthebasicprintedcircuitboard Potentiometersettings Thebasicprintedcircuitboardhastwopotentiometers toadjusttheventilationunit.Thepotentiometerscanbe adjustedtosettheminimumand/ormaximumcapacity. Potentiometer1adjuststhelowsettingfortheunit. Thispotentiometerislimitedonthelowerside,sothere canneverbetoolittleventilation.Thefactorysettingis TheCVEECO2RFTunitiscontrolledusingtheradio 75m3/h.Thispotentiometershouldbeadjustedtoachieve frequencymodule.Forinformationaboutinstallingand theminimumrateasdefinedinADF.Iftheminimum operatingtheRFToption,pleaserefertothehandbook ratecannotbeachievedatlowspeedthenthemedium providedwiththeRFTremotecontrolset. speedshouldbesettotheADFminimumrateinstead. Themediumspeediscalculatedautomaticallybythe unit,itisdefinedbyadifferenceinthelowandhigh speeds.Potentiometer2adjuststhehighspeedsetting. 22 211.0599 CVE ECO-fan ENG.indd 22 25-07-11 16:19 Thispotentiometerhasafactorysettingof225m3/h. Removalofthefrontcover Thehighspeedshouldbeadjustedtothehighrate Thefrontcovercanberemovedusingascrewdriver. asdefinedinADF.Theavailablerangeis175m3/hto Theclaspisonthe(left)topsideofthecoverandthe 325m3/h(at150Pa). extractorcase.Thecovercanbe“pressedopen”by horizontallyinsertingascrewdriverintotheclasp. Whensettingupthesystemifmoreventilationisneeded, Thecovercanthenbepulledoutbyhand. openthevalvesmorefullytoobtaintherequiredcapacity beforeadjustingthespeed.Increasingtherpmsofthe Removalofmotorchassiswithmotor/fanassembly motorleadstoincreasedenergyconsumptionandhigher Therearethreeslotsonthemotorchassis.Theclamps noiselevels. intheslotsarereleasedbyinsertinga(flat-blade) screwdriverintothemotorchassisandpullingthe screwdriverhandletowardsthemotorchassis.Afterthe clampsinallthreeslotshavebeenopenedinthisway, aliftingstrip(atthetoprightofthechassis)canbeused toremovetheentiremotorchassis,includingthemotor andfan. 23 211.0599 CVE ECO-fan ENG.indd 23 Itho | cve eco 2 rft 25-07-11 16:19 9 Manufacturer’sstatement ECdeclarationofconformity Mechanicalextractunit AccordingtoLowVoltageDirective2006/95/ECandthe type:CVEECo2RFt EMCDirective2004/108/EC isinconformitywiththefollowingECCouncilDirectives: - LowVoltageDirective2006/95/EC DeclarationofIncorporation - EMCDirective2004/108/EC AccordingtoAnnexIIBoftheMachineryDirective 2006/42/EC, andAppliedHarmonisedStandards: - EN60730-1 IthoImagesBV - EN61000-3-2 Soevereinstraat8 - EN61000-6-1 4879NN Etten-Leur - EN61000-6-3 TheNetherlands - RoHs/Weee herebydeclareunderoursoleresponsibilitythatthe andmustberegardedaspartlycompletedmachinery followingproducts: andisintendedtobeincorporatedinamachineortobe 24 211.0599 CVE ECO-fan ENG.indd 24 25-07-11 16:19 assembledwithothermachinesintoasinglemachine AfterthesubmissionofadeclarationaccordingtoAnnex orsystemtowhichtheMachineryDirective2006/42/EC IIAoftheMachineryDirectivefortheentireinstallation, applies. theCEmarkingonthedevicealsoreferstotheMachinery Directive2006/42/EC. Wewanttoalertyouthattheproductisdesignedtobe incorporatedinaventilationsystemandthatthepartly completedmachinemustnotbeputintoserviceuntil thefinalmachineryintowhichitistobeincorporatedis inconformitywiththeprovisionsofMachineryDirective 2006/42/ECforwhichthemostimportantinstructionscan befoundinthemanual. WeexplicitlystatethattheCEmarkingontheproductonly Etten-Leur,July2011 referstotheLowVoltageDirective2006/95/ECandthe J.Braspenning EMCDirective2004/108/EC Director 25 211.0599 CVE ECO-fan ENG.indd 25 Itho | cve eco 2 rft 25-07-11 16:19 10 ECDeclarationofConformity AccordingtoAnnexIIoftheMachineryDirective2006/42/EC. We: Nameofinstaller: Fulladdressandcountry: Herebydeclareunderourownresponsibility,tohaveinstalledthefollowingproductwithtypedesignation: Mechanicalextractunit type:CVEECo2RFt towhichthisdeclarationrefers.Wedeclaretheentireinstallation(beingasinglemachine)inconformitywiththe MachineryDirective. Place: Signature: Date: CompanyStamp: Name: Position: 26 211.0599 CVE ECO-fan ENG.indd 26 25-07-11 16:19 Notes 27 211.0599 CVE ECO-fan ENG.indd 27 Itho | cve eco 2 rft 25-07-11 16:19 Climate forlife Ithostrivesatalltimestoofferpeople harmoniouslytogether.Wewantamore withverylittleeffort.Youcanrecognise anenjoyablelivingandworking comfortableandhealthierliving thesesolutionsbytheIthoLivingBlue environmentwithitsinnovativesolutions environmentbutatthesametime,we label.Ouraimistodevelopclimate inclimatesystems.Thesearesolutions aimforlowerenergyconsumption. systemsthatrespecttheworldaround fortemperature,cleanairandhot Withsustainabletechnologiesand us.Yourwishesbecomeourinspiration waterinthedomesticenvironmentin innovations,Ithoprovesthatseemingly andIthoworksconstantlytoachieve whichpeopleandenvironmentgo oppositeobjectivescanbecombined this:Climateforlife. 211.0599 CVE ECO-fan ENG.indd 1 0711/ED IthoUKLtd 10 Faraday Court First Avenue Burton on Trent Staffordshire DE14 2WX T +44 (0) 845 250 8090 F +44 (0) 845 250 8091 E [email protected] I www.itho.co.uk 25-07-11 16:19