Download TUTA S30 - Oomipood

Transcript
TUTA S30
GSM Power Socket
TUTA S30 GSM POWER SOCKET USER MANUAL
User Manual
Manual version 1.2
2
TUTA S30 GSM POWER SOCKET USER MANUAL
TUTA S30 GSM Power Socket
Thank you for purchasing the TUTA S30.
The TUTA S30 GSM power socket is a remote controlled socket
consisting of a GSM module. The power supply output of the socket can
be turned on or off remotely by the SMS (Short Message System)
command or local controlled by pressing button. It is an intelligent power
supply socket controlled by users’ mobile phone at anytime and
anywhere.
TUTA S30 is suitable for controlling electrical appliances which power
consumption less than 3000W in household or office. It is universal for
all kinds of indoor power supply sockets.
With extended-connected temperature sensor, TUTA S30 can switch on
or off the socket outpu#t according to the environment temperature. It’s
available for power control of the heating or refrigeration plant, to keep
the environmental temperature within presetting range or at a fixed
temperature value. Furthermore, a SMS notification will be sent to
master’s mobile phone if TUTA S30 detects the rapid-changing or the
3
TUTA S30 GSM POWER SOCKET USER MANUAL
reaching of pre-set alert value of surroundings temperature.
TUTA S30 is mainly applied for house and office usage. It is not suited
for industry application, especially in humidity or dust condition.
All services and functions need to be supported by the GSM network
and a SIM card.
This brochure suits for TUTA S30 model.
Details of the functioning and advanced operation of this socket are
described in this instruction manual.
4
TUTA S30 GSM POWER SOCKET USER MANUAL
For your safety................................................................8
Exception clause...........................................................10
Chapter 1 Features and accessories...............................12
1.1 Main function..........................................................12
1.2 Package contents ...................................................14
1.3 Sockets instructions................................................16
1.4 Light indicator and “Beep” warning tone..............18
Chapter 2 Quick start.....................................................20
2.1 Install the SIM card and temperature sensor..........20
2.2 GSM Power on/ off.................................................21
2.3 Add a Master number to the socket........................22
2.4 The regulation of time.............................................23
2.5 Socket output switching on/off................................23
5
TUTA S30 GSM POWER SOCKET USER MANUAL
2.6 External power supply notification.........................24
Chapter 3 Advanced settings..........................................26
3.1 Define the users......................................................26
3.2 Change password....................................................31
3.3 Switching on/off the socket output manually..........31
3.4 Delayed-switch on/off the socket output.................34
3.5 Timed switching on the socket output.....................36
3.6 Auto-control the socket output by temperature.......39
3.7 Temperature alarm..................................................43
3.8 SMS notification upon the socket output changing.45
3.9 SMS notification upon external power supply
changing........................................................................46
3.10 “Beep” warning tone............................................47
3.11 Check status..........................................................48
3.12 Resetting the socket...............................................50
6
TUTA S30 GSM POWER SOCKET USER MANUAL
Chapter 4 Maintenance...................................................52
Chapter 5 General Troubleshooting..............................54
Chapter 6 Main Technical Parameters..........................57
Appendix: SMS commands list......................................58
7
TUTA S30 GSM POWER SOCKET USER MANUAL
1. Purchase a GSM SIM card (mobile phone card) from
GSM network service provider and install it in the
socket. This SIM card number is referred as TUTA S30
number on this brochure.
2. The user needs to activate the Caller ID Presentation
function of SIM card, and deactivate PIN code of the
SIM. Contact with GSM network service provider for
support.
3. Change the original password at the beginning use. Be
sure to keep the password and SIM card number
secret. Do not disclose this information to anyone
other than the authorized users in order to ensure
your safety.
For your safety
λ
This socket was designed for home or office use. Do not use it on
8
TUTA S30 GSM POWER SOCKET USER MANUAL
the electrical appliance which is for industry or business operation,
for example, iatrical appliances, large heaters and refrigerates.
λ
Before using this socket, make sure that the mobile phones can be
used well in the area, otherwise, do not put this socket into
operation.
λ
The power consumption of the appliances connected with the
socket cannot exceed 3000W and the current cannot exceed 16A.
λ
The electrical appliance which power consumption is higher than
1500W must be grounded.
λ
Do not make two plugs of socket short circuit.
λ
Do not touch the socket jack by any metal objects or hand.
λ
This socket was designed for indoor use. Don’t use it in wet,
chemically aggressive or dusty environment.
λ
Do not open the case unless maintenance needed.
λ
Do not keep shaking or fall down this socket, otherwise it can be
damaged.
λ
This socket is a wireless signal transmission socket. Keep it away
from electronic equipment likely to interfere with the wireless
signals, in order to avoid signals interference.
λ
Switch off this socket and mobile phone when entering areas
marked "Explosive", "Might explode", "Closed wireless transceiver
9
TUTA S30 GSM POWER SOCKET USER MANUAL
sockets" etc.
λ
λ
Do not cast this socket in a fire, as this may cause explosion.
This socket should only be operated from power approved by the
socket manufacturer. The use of any other types of power may
damage the socket.
λ
Keep the socket and its accessories out of the children reach.
Exception clause
1. We operate on a policy of continuous development. We reserve the
right to make changes and improvements to any of the sockets
described in this document without prior notice.
2. For the latest socket information, please visit: http://www.i-tuta.com.
We don’t guarantee for the document veracity, reliability or any
content except regulate in proper laws. Including no guarantee for
socket suitable market or suitable area promise.
3. We hold no responsibility for the illegal use of this socket.
4. We hold no responsibility for any loss of income or any special,
incidental, consequential or indirect damages howsoever caused.
5. The contents of this document are provided “as is”. Except as
required by applicable law, no warranties of any kind, either
10
TUTA S30 GSM POWER SOCKET USER MANUAL
expressed or implied, including, but not limited to the accuracy,
reliability or contents of this document. We reserve the right to
revise this document or withdraw it at any time without prior notice.
11
TUTA S30 GSM POWER SOCKET USER MANUAL
Chapter 1 Features and accessories
1.1 Main function
λ
This socket uses a GSM SIM card.
λ
Remotely operate by SMS command: The socket be controlled and
set by sending SMS commands.
λ
Input: 110V-250V/50Hz.
λ
Output: Max.16A for long-duration operation.
λ
Relay: 30A/250V relay with two working status power on/off for
output outlet.
λ
M button: To manual control output power on/off.
λ
Delayed control socket output.
λ
Auto operates by preset schedule: Fixing-time control output power
on/off.
λ
External temperature sensor supported: Send environmental
temperature SMS to mobile phone.
λ
Auto operates by temperature: Available for power control of the
heating
or
refrigeration
plant,
12
to
keep
the
environmental
TUTA S30 GSM POWER SOCKET USER MANUAL
temperature within presetting range or at fixed temperature value.
λ
SMS alarm when temperature rapid-changing or reaching the preset value: When it detects the rapid-changing or the reach of preset alert value of surroundings temperature, it can auto-send the
SMS alarm message to master’s mobile phone.
λ
λ
λ
Support 5 mobile phone users.
Auto time-synchronization.
SMS notification upon external power source changing.
13
TUTA S30 GSM POWER SOCKET USER MANUAL
1.2 Package contents
GSM power socket(1 unit)
14
TUTA S30 GSM POWER SOCKET USER MANUAL
Temperature sensor(1 unit)
User manual(1 unit)
15
TUTA S30 GSM POWER SOCKET USER MANUAL
1.3 Sockets instructions
16
TUTA S30 GSM POWER SOCKET USER MANUAL
Figure 1: TUTA S30 instructions
17
TUTA S30 GSM POWER SOCKET USER MANUAL
Figure 2: Temperature sensor Instruction
1.4 Light indicator and “Beep” warning tone
Indicator
Action
Power
Turning off
No power supply input
Constant
Has power supply input
(Green) light
Status
light
GSM (Blue)
Turning off
light
Not installed SIM card, or the power
switch of socket is “OFF”.
Flash
Be busy or searching GSM network.
Constant
Successfully load to GSM network.
light
Output (Red)
light
Constant
The socket outlet has power supply.
light
18
TUTA S30 GSM POWER SOCKET USER MANUAL
“Beep”
Turning off
The socket outlet cuts power supply.
One time
The socket outlet changes power
warning tone
(Default
turning off)
supply status.
Several
TUTA S30 lost external power supply.
times
Long Beep
TUTA S30 is successfully register
GSM network, or it is successfully
reset to its factory settings.
Note: The “Beep” warning tone can be turn on or turn off by SMS
command. Refer to Chapter 3.9 for details.
19
TUTA S30 GSM POWER SOCKET USER MANUAL
Chapter 2 Quick start
2.1 Install the SIM card and temperature sensor
λ
Turn the power switch to “OFF” position.
λ
Loosen the screw and open the socket’s SIM cover; you will see a
SIM card holder.
λ
Push the metallic cover of the holder to “OPEN” direction and open
the SIM card holder.
λ
Put the SIM card on the card holder, ensuring that the beveled
corner is toward the beveled corner of the SIM holder and the
golden contact area is facing downwards.
λ
Cover back the metallic cover and push it to “LOCK” direction. The
SIM card will be fixed in the holder.
λ
Screw the SIM cover back.
λ
Insert the temperature sensor into the I/O port until it is seized.
20
TUTA S30 GSM POWER SOCKET USER MANUAL
2.2 GSM Power on/ off
Power on:
1. Turn the power switch to “On” position (See 7 on Figure1).
2. Plug the TUTA S30 in an AC power socket (See 6 on Figure1).
The blue light will be flashing slowly for about 20 seconds, then blue
light be on constantly and a long “Beep” tone can be heard (if “Beep”
warning tone is enabled).
The default state of the socket outlet is no power supply output.
3. Insert the plug of electronic appliance in the TUTA S30 electrical
outlet (See 4 on Figure1).
4. M button (See 3 on Figure1) can be pressed for about 0.5 second to
switch on or off the output of socket.
After adding user numbers to the socket, users can send SMS
command to control the power supply output. (Refer to Chapter 3.2)
Power off:
1. Turn the power switch to “Off” position. The blue light turns off.
2. The socket outlet can work as a normal power socket. TUTA S30 can
not be controlled by SMS commands. M button is disabled.

Note:
1.
If the GSM indicator light is not constant lights, which imply
21
TUTA S30 GSM POWER SOCKET USER MANUAL
the SIM card working abnormally, all functions of this socket
are invalid.
2.
Check GSM network signal of the using place:
•
The GSM network’s signal strength may affect the
socket feature. Therefore, before using, the user should
ensure that TUTA S30 is used in an area with a strong
GSM network signal.
•
For the first time use, the user should perform a test-run
by sending SMS to the socket. This allows the user to
check the GSM network connection of the socket.
2.3 Add a Master number to the socket
The user must edit and send the following SMS to socket via his/her
mobile phone (the phone number will be the Master number) in order to:
Add a Master number to the socket: #00#
 Successful SMS reply
Welcome to use TUTA-S30.
Your Password is:1234.
22
TUTA S30 GSM POWER SOCKET USER MANUAL
2.4 The regulation of time

Important note
If TUTA S30 is being used for the first time, or it has been reset,
the Master user must adjust the socket time according to the
current time of SMS center. Otherwise, TUTA S30 will use the
original time from 00:00:00, 1st.Jan.2004.
 Method
The Master user sends following SMS message in order to:
Regulate the socket time: #152#SIMCardNumber#
•
(1)
The SIMCardNumber should be the SIM card number of
TUTA S30.
 Successful SMS reply
The socket current time is yyyy/mm/dd hh:mm.
2.5 Socket output switching on/off
 Method
Method 1:To press M button 0.5 second (See 3 on Figure1).
23
TUTA S30 GSM POWER SOCKET USER MANUAL
Method 2:
The Master user sends following SMS message to socket in order to:
Switch on the socket output:
#01#
Switch off the socket output:
#02#
 Successful SMS reply
Status: ON/OFF
Temp:**
Temp control: function ON/OFF
Schedule control: function ON/OFF
Delay control: function OFF
2.6 External power supply notification
TUTA S30 will notify the user when the external power changes. The
“Beep, Beep…” tones will be heart (if enabled), also a SMS notification
will be sent if the SIM card is available:
Lost external power supply:
If the plug of TUTA S30 is disconnected from external AC power or lost
of the AC power occurs, all operating on TUTA S30 is de-activated,
including M button and all SMS commands. TUTA S30 will notify the
24
TUTA S30 GSM POWER SOCKET USER MANUAL
user “Main electricity supply lost
Temp:**”.
Resume external power supply:
If the AC power of TUTA S30 is available again, the SMS notification will
be sent to the user, i.e.” Main electricity supply restore Status: ON/OFF
Temp:**”
When the external power supply is resumed, the output of TUTA S30 will
keep its previous working status. For example, if the output is switched
on before the external power supply cut off, the output will be switched
on when the external power supply is resumed.
If the power supply is switched on and off frequently, TUTA S30 will send
reminding SMS messages.
The SMS notification upon external power supply changing can be
disabled. (Refer to Chapter 3.8)
25
TUTA S30 GSM POWER SOCKET USER MANUAL
Chapter 3 Advanced settings
3.1 Define the users
3.1.1 User authorization level
All the settings of TUTA S30 can be set or adjusted via a SMS
command.
There are two mobile phone user controlling levels:
Master user:
Only one Master user has authorization to use all features of TUTA
S30.
In order to enable all the functions on the socket, the Master user
must store his/ her mobile number in the socket’s memory. Only one
Master’s mobile number (Master number) is allowed for a socket.
Family users:
There are four Family users have authorization to use two
commands of switch on or cut off the socket output.
26
TUTA S30 GSM POWER SOCKET USER MANUAL
The other mobile phone users have no authorization to use TUTA
S30.
3.1.2 About the SMS Command
•
•
Master user’s SMS command format: #code#content#.
•
The password must be a four-digit number.
•
The original password is 1234.
•
The maximum digits that are allows for the phone number is sixteen.
•
TUTA S30 will reply to the user after it receives the SMS command.
Family users’ SMS command format: #code#content#password#.

Note
•
The “#” symbol must not be ignored when typing an SMS
command.
•
No allow any space within the commands.
3.1.3 Add a master number to the socket
 Description
If TUTA S30 is being used for the first time, or TUTA S30 has
been reset to factory settings, the Master user’s number must be
programmed into the socket.
27
TUTA S30 GSM POWER SOCKET USER MANUAL
 Method
The user must edit and send the following SMS to socket via
his/her mobile phone (the phone number will be the Master
number) in order to:
Add a master number to the socket:
#00#
(2)
 Successful SMS reply
Welcome to use TUTA-S30.
Your Password is:1234..
 Failed SMS reply
If a user tries to add another Master user again, TUTA S30 will
send a notification via SMS stating “The master user already
exists.”. The Master number should be changed. (Refer to
Chapter 3.1.4)
3.1.4 Change the master number
 Method
Method 1:
The Master user sends following SMS message in order to:
Change the master user’s number: #14#NewMasterNumber (3)
28
TUTA S30 GSM POWER SOCKET USER MANUAL
•
NewMasterNumber should be the new Master user’s
mobile phone number.
Method 2:
TUTA S30 should be reset to factory settings to remove old
Master number before setting the new one. (Refer to Chapter
3.11)
 Successful SMS reply
New master number set successfully.
Successful SMS reply will be sent to the new Master user. Then
the old Master user’s number will not be able to control TUTA
S30 anymore.
3.1.5 Add a family number
Up to 4 family users’ number can be stored on one socket.
Family users have the authority to send SMS command to switch on or
cut off the TUTA S30 output. The family users should remember and
safeguard the socket’s SIM number.
 Method
The Master user sends following SMS message in order to:
Add a family number:
29
TUTA S30 GSM POWER SOCKET USER MANUAL
#06#FamilyNumber#
(4)
Add several family numbers:
#06#FamilyNumber1#...#FamilyNumber4#
•
(5)
FamilyNumber should be the Family user’s mobile phone
number.
 Successful SMS reply
#******# Family numbers set successfully.
3.1.6 Check family user’s number
Refer to Chapter 3.10 Check status.
3.1.7 Delete family number
 Method
The Master user sends following SMS message in order to:
Delete a family number:
#113#FamilyNumber#
(6)
Delete several family numbers simultaneously:
#113#FamilyNumber1#…#FamilyNumber4#
Delete all family numbers:
#113#
 Successful SMS reply
30
(8)
(7)
TUTA S30 GSM POWER SOCKET USER MANUAL
#******# Family number has been deleted.
 Failed SMS reply
#******# The family number does not exist.
3.2 Change password
 Method
The Master user sends following SMS message in order to:
Change the password: #04#Oldpassword#Newpassword#
•
•
(9)
The password is a four digit number.
The original password is 1234.
 Successful SMS reply
New password is ****.
3.3 Switching on/off the socket output manually
 Description
•
When the socket output is switching on, TUTA S30 offers power
supply for electronic appliance which being connected with it; the
red indicator light is lighted constantly. Otherwise, TUTA S30 has no
power supply for electronic appliance and the red light is turned off.
•
Note: If the socket output status is changed manually (including
31
TUTA S30 GSM POWER SOCKET USER MANUAL
pressing the M button, sending SMS, making phone call), the preset
timing, delaying or temperature control of the socket will be invalid
automatically and a SMS notification message will be sent to the
Master, but the setting time range and temperature range
parameters will be saved until TUTA S30 is reset to factory settings.
3.3.1 Switching on/off by SMS
 Method
The Master user sends following SMS message in order to:
Switch on the socket output manually:
Cut off the socket output manually:
#01#
#02#
(10)
(11)
The Family users send following SMS message in order to:
Switch on the socket output manually: #01#Password#
Cut off the socket output manually:
•
•
#02#Password#
(12)
(13)
Password should be 4 digits password number. Default 1234.
SMS reply will be also sent to Master user when Family users use
these two commands to change the socket output successfully.
 Successful SMS reply
Status: ON/OFF
Temp:**
Temp control: function ON/OFF
32
TUTA S30 GSM POWER SOCKET USER MANUAL
Schedule control: function ON/OFF
Delay control: function ON/OFF
3.3.2 Switching on/off by M button
Keep press M button on the TUTA S30 for half a second. The
OUTPUT indecator light will turn on or off to indicate that TUTA
S30 output is switching on or off.
The SMS reply is same with Chapter 3.2.1.
3.3.3 Switching on/off by calling
 Description
If the Master user calls TUTA S30, the socket output will be
switched on or cut off automatically when the user hears the ring
tone in the phone. The calling will be hung up automatically if the
user doesn’t hang up the call.
 Method
The Master user sends following SMS message in order to:
Enable switching on/off the output by calling:
#18#1#
(14)
Disable switching on/off the output by calling (Default):
33
TUTA S30 GSM POWER SOCKET USER MANUAL
#18#0#
(15)
 Successful SMS reply
Control the socket power output status by calling activated /deactivated.
3.4 Delayed-switch on/off the socket output
 Description
•
The output of TUTA S30 can be set to delay switch on or off for a
period with SMS commands.
•
When the “delayed-switch on/off the socket” function is applied, the
preset “timed switch on the output” function will be invalid at once.
•
When the “delayed switch on the socket” command is received and
if the socket output is switched on, the socket output will be
switched off immediately and be switch on again as the setting
delayed time is reaching. Contrarily, if the socket output is switched
off, the output will remain switching off until the setting delayed time
is reaching. Afther switching on the output, the following SMS reply
will be sent:
Status: ON
34
TUTA S30 GSM POWER SOCKET USER MANUAL
Delay control: function OFF
•
When the “delayed switch off the socket” command is received and
if the the socket output is switched on, the socket output will remain
the switch on state and be switched off as the setting delayed time
is reaching. If the socket output is switched off, it will be switched on
immediately and be switch off again when reaching the setting
delayed time. After switching off the socket output, the following
SMS reply will be sent:
Status: OFF
Delay control: function OFF
 Method
The Master user sends following SMS message in order to:
Delay switching on the output after a certain minutes:
#138#1#Minutes#
(16)
Delay switching off the output after a certain minutes:
#138#0#Minutes#
•
•
(17)
Minutes are time parameters, its range is 0-720,
When Minutes is 0, the “delayed switch on/off the socket” function
will be invalid, but the current output status won’t be changed.
 Successful SMS reply
35
TUTA S30 GSM POWER SOCKET USER MANUAL
Status: ON/OFF
Output will switch off/on after * minutes.
3.5 Timed switching on the socket output
3.5.1 Enable timing switching on the output
 Description
•
The output of TUTA S30 can be set to switch on for a duration and
then be switch off after the duration.
•
If the socket output status is changed manually (including pressing
M button, sending SMS and making phone call), the preset timing,
delaying or temperature control of the socket will be invalid
automatically, but the setting time range parameters will be saved
until TUTA S30 is reset to factory settings. If these functions need to
be restarted, the following SMS commands must be set: Timing
#128#1#, Temperature control #159#1#, “delayed switch on/off the
socket” commands need to be reset.
 Method
The Master user sends following SMS message in order to:
Enable timing switch on the output:
36
#128#1#
(18)
TUTA S30 GSM POWER SOCKET USER MANUAL
 Successful SMS reply
Schedule control: function ON
WorkDay, StartTime-EndTime
If the value of the “WorkDay, StartTime, EndTime” on the SMS
reply are all 0, it means the time duration has not been set.
(Refer to 3.4.2)
Then TUTA S30 will keep switching on or off the output
automatically according to the schedule settings.
3.5.2 Set time period to switch on the output
 Description
After successful setting of time duration to switch on the socket
output, the schedule parameter will be saved on the socket until
TUTA S30 is reset to factory settings.
But the “timed switch on the output” feature is applied only when
command 17 be set.
 Method
The Master user sends following SMS message in order to:
Set time period to switch on the output:
#129#WorkDay#StartTime#EndTime#
37
(19)
TUTA S30 GSM POWER SOCKET USER MANUAL
•
WorkDay: one digit, the values lie in the range of “0” to “8”.
The following table contains the descriptions of each value:
Value
•
Corresponding day
0
Sunday
1
Monday
2
Tuesday
3
Wednesday
4
Thursday
5
Friday
6
Saturday
7
Everyday
8
Monday to Friday
StartTime and EndTime: Be consists of 4 digits (hh:mm) and works
on a 24 hour clock. The StartTime and EndTime should be in the
same day, and the EndTime must be later than StartTime.
•
The socket output will switch on at the StartTime and cut off at the
EndTime.
•
For
example:
#129#1#0000#2130#
,
00:00(hh:mm)AM, 2130 means time 9:30PM.
38
0000
means
time
TUTA S30 GSM POWER SOCKET USER MANUAL
 Successful SMS reply
Schedule control: function ON/OFF
WorkDay, StartTime-EndTime
3.5.3 Disable timing switching on the output
 Method
The Master user sends following SMS message in order to:
Disable timing switch on the output: #128#0#

(20)
Successful SMS reply
Schedule control: function OFF
WorkDay, StartTime-EndTime.
3.6 Auto-control the socket output by temperature
3.6.1 Enable auto-controlled by temperature
 Description
•
The external temperature sensor must be inserted into the I/O port
of TUTA S30. The output status of the socket can be controlled by
the environmental temperature automatically.
•
If users don’t open the “timed switch on the socket” or “delayed
switch on/off the socket” functions, the socket will control to switch
39
TUTA S30 GSM POWER SOCKET USER MANUAL
on or cut off the output according to temperature setting.
•
If users open the “timed switch on the socket” or “delayed switch
on/off the socket” functions, the temperature control function will
only be valid when power output is switch on (including timed switch
on or delayed switch on time period).
•
For example: TUTA S30 is used for the power control of the heating
apparatus. If users set the socket output on when indoor
temperature is bellow 20 degrees and off when indoor temperature
is above 28 degrees. Meanwhile, users set the TUTA S30 output is
on from 9am to 5pm. In this case, the socket will control to switch
on or off the output according to indoor temperature automatically
from 9am to 5pm duration.
 Method
The Master user sends following SMS message in order to:
Enable auto-control the output by temperature:
 Successful SMS reply
Status: ON/OFF
Temp control: function ON
Temp: **
Mode: Heating/Cooling
Range: LowTemp ~ HighTemp
40
#159#1#
(21)
TUTA S30 GSM POWER SOCKET USER MANUAL
Then TUTA S30 can switch on or off the output automatically
according to the temperature range setting.
3.6.2 Set temperature range to switch on/off the output
 Description
After successful setting of temperature range, the temperature
parameter will be saved on the socket until TUTA S30 is reset to
factory settings.
But the “Auto-controlled by temperature” feature is applied only
when command 20 be set.
 Method
The Master user sends following SMS message in order to:
Set temperature range to switch on/off the output:
#159#Mode#LowTemp#HighTemp#
•
(22)
Mode is the control selection:
For coldness, mode=1. For warmness, mode=0.
•
LowTemp and HighTemp means temperature value, the range is
-10 to 50 centigrade degree, if LowTemp equals to HighTemp,
constant temperature control will be actived.
41
TUTA S30 GSM POWER SOCKET USER MANUAL
•
Temperature unit is degree Celsius.
•
Example 1: set commands: #159#0#10#20#, if the environmental
temperature is 5 degrees (bellow the limitation of 10 degrees in the
command), the socket output will be switched on to power heating
apparatus; and if the environmental temperature is 24 degrees
(above the limitation of 20 degrees in the command), the socket
output will be switched off and the heating apparatus stops working;
•
Example 2: set commands: #159#1#10#20#, if the environmental
temperature is 26 degrees (above the limitation of 20 degrees in the
command), the socket output will be switched on to power cooling
apparatus; and when the environmental temperature is 7 degrees
(bellow the limitation of 10 degrees in the command), the socket
output will be off, cooling apparatus stops working.
 Successful SMS reply
Status: ON/OFF
Temp control: function ON/OFF
Temp: **
Mode: Heating/Cooling
Range: LowTemp ~ HighTemp
42
TUTA S30 GSM POWER SOCKET USER MANUAL
3.6.3 Disable auto-controlled by temperature
 Method
The Master user sends following SMS message in order to:
Disable auto-control the output by temperature: #159#0#
(23)
 Successful SMS reply
Status: ON/OFF
Temp control: function OFF
Temp: **
Mode: Heating/Cooling
Range: LowTemp ~ HighTemp
3.7 Temperature alarm
3.7.1 Over-temperature alarm
 Description
A range of temperature can be pre-set onto the socket. In this case,
if the surroundings temperature is detected out of the pre-set
temperature range, the TUTA S30 will auto-send the SMS alarm
message to master’s mobile phone.
This feature depends on the temperature sensor.
43
TUTA S30 GSM POWER SOCKET USER MANUAL
 Method
The Master user sends following SMS message in order to:
Enable over-temperature alarm: #170#1#
(24)
Set limits of temperature: #170#MinTemp#MaxTemp#
•
(25)
MinTemp and MaxTemp: The values can be set within the range
of -10 to 50 centigrade degree.
Default MinTemp is 20 and MaxTemp is 30 centigrade degree.
Disable the alarm upon going beyond limits temperature:
#170#0#
(26)
 Successful SMS reply
Temperature alert: function ON/OFF
Min Temp.:**
Max Temp.: **.
3.7.2 Temperature rapid-changing alarm
 Description
A time period value and temperature changing value can be pre-set
onto the socket. In this case, if the surroundings temperature
change to the pre-set value within the pre-set time period, a SMS
alarm message will be auto-sent to master’s mobile phone.
44
TUTA S30 GSM POWER SOCKET USER MANUAL
This feature depends on the temperature sensor.
 Method
The Master user sends following SMS message in order to:
Enable the temperature rapid changing alarm: #160#1#
(27)
Set time period and temperature changing value:
#160#Temp#Time#
•
•
•
(28)
Temp: The values lie in the range of 1 to 50 centigrade degree.
Time: The values lie in the range of 1 to 300 minutes.
Default Temp is 2 degree and Time is 1 minute.
Disable the temperature rapid changing alarm:
#160#0# (29)
 Successful SMS reply
Fast temperature changing.: function ON/OFF
Delta:**
Time:* minutes
3.8 SMS notification upon the socket output changing
 Description
TUTA S30 will default notify the user when the state of the socket
output is changed with a SMS notification. The Master user can
enable/disable this SMS notification.
45
TUTA S30 GSM POWER SOCKET USER MANUAL
 Method
The Master user sends following SMS message in order to:
SMS notification upon the socket output changing (Default):
#11#1#
(30)
No SMS notification upon the socket output changing:
#11#0#
(31)
 Successful SMS reply
Set no SMS notification when socket output changed.
Set SMS notification once socket output changed.
3.9 SMS notification upon external power supply
changing
 Description
TUTA S30 will default notify the user when the state of the
external power supply is changed with a SMS notification. For
example:
Main electricity supply lost
Temp:**
or
Main electricity supply restore
46
TUTA S30 GSM POWER SOCKET USER MANUAL
Status: ON
Temp:**
The Master user can enable/disable this SMS notification.
 Method
The Master user sends following SMS message in order to set:
SMS notification upon the power supply changing (Default):
#12#1#
(32)
No SMS notification upon the power supply changing: #12#0# (33)
 Successful SMS reply
(No) SMS notification upon main electricity supply changing.
3.10 “Beep” warning tone
 Description
A “Beep” warning tone will be sounded if the work state of TUTA S30
is changed. The “Beep” warning tone is default turning off. The
Master user can enable it by sending SMS command.
 Method
The Master user sends following SMS message in order to:
Enable the “Beep” warning tone:
#19#1#
Disaable the “Beep” warning tone (Default):
47
(34)
#19#0#
(35)
TUTA S30 GSM POWER SOCKET USER MANUAL
 Successful SMS reply
Beep alarm activated/de-activated.
3.11 Check status
 Method
The Master user sends following SMS message in order to:
Check socket operating status:
#07#
(36)
After receiving the SMS commands, TUTA S30 will reply one SMS
message of socket status checking:
Number:***********,**********
Status: ON/OFF
TEMP:**
Temp control:function ON/OFF
Schedule control:function ON/OFF
Delay control:function ON/OFF
Check socket output status:
#000#
(37)
After receiving the SMS commands, TUTA S30 will reply one SMS
message of socket output status:
Status: ON
Temp:23.
48
TUTA S30 GSM POWER SOCKET USER MANUAL
Check “delayed switch on/off the socket” parameters: #138# (38)
After receiving the SMS commands, TUTA S30 will reply one SMS
message of “Delayed switch on/off the socket” parameters checking:
Status: ON/OFF
Output will switch off/on after ** minutes.
Check “Timing switch on the socket” parameters: #128#
(39)
After receiving the SMS commands, TUTA S30 will reply one SMS
message of “Timing switch on the socket” parameters:
Schedule control: function ON/OFF
WorkDay, StartTime-EndTime.
Check “Temperature control” parameters:
#159#
(40)
After receiving the SMS commands, TUTA S30 will reply one SMS
message of temperature parameters checking:
Status: ON/OFF
Temp control: function ON/OFF
Temp: **
Mode: Heating/Cooling
Range: LowTemp ~ HighTemp
If “No temperature sensor connected” be received, it means TUTA
S30 cannot detect the temperature sensor. User needs to check if
the temperature sensor is inserted to the I/O port.
49
TUTA S30 GSM POWER SOCKET USER MANUAL
Check “temperature rapid changing alarm” parameters: #160# (41)
After receiving the SMS commands, TUTA S30 will reply one SMS
message of parameters. It means SMS alarm message will be sent
upon the surrounding temperature changes “Delta” centigrade
degree within * minutes:
Fast temperature changing.: function ON/OFF
Delta: *
Time: * minutes
Check “over-temperature alarm limits” parameters: #170#
(42)
After receiving the SMS commands, TUTA S30 will reply one SMS
message of parameters. It means SMS alarm message will be sent
upon temperature reaches MinTemp or MaxTemp centigrade
degree:
Temperature alert: function OFF
Min Temp.: **
Max Temp.: **
3.12 Resetting the socket
 Description
•
This function resets all programmed settings to their original values,
50
TUTA S30 GSM POWER SOCKET USER MANUAL
including
cleaning
all
user number,
timing
parameter and
temperature parameter.
•
If the setting status is wrong or the malfunctions can’t be corrected,
users can restore the socket to its original status to make it work
normally.

Note
This function needs to be used carefully as it also erases all setting
values.
 Method
Method 1: Press the side M button of the device for 5 seconds.
Method 2: The Master user sends following SMS message to TUTA
S30 in order to:
Reset the socket:
#08#
(43)
 Successful SMS reply
Reset the socket to factory setting successfully.
A long “Beep” tone (if enabled) will be heard and it means resetting
the socket successfully.
51
TUTA S30 GSM POWER SOCKET USER MANUAL
Chapter 4 Maintenance
•
If TUTA S30 does not in use for long time, it should be
powered off.
•
Store and use the remote socket in suitable temperature.
Too high or too low temperature will likely to damage the
socket.
•
Try to keep the TUTA S30 and all its accessories dry. Do
not store and use it in the bathroom, or other place with
high humidity. Do not allow pour water or other liquids
into the socket, otherwise, it might cause malfunctions.
•
Do not store and use the socket in dusty.
•
Do not use alcohol, acetone and other similar solvents to
clean it. Wipe it with soft-wet cloth.
52
TUTA S30 GSM POWER SOCKET USER MANUAL
•
Do not attempt to open it except as instructed. If the
socket does not work normally, try to resolve it as the
guide of the "general troubleshooting", if to the problem
can not be solved, contact with the dealer immediately.
53
TUTA S30 GSM POWER SOCKET USER MANUAL
Chapter 5 General Troubleshooting
No.
General
Possible Reason
Solution
Trouble
1
2
3
Power
No power input.
Check TUTA S30’s
indicator light
external AC power is
turns off
available.
GSM
Can’t find or
SIM card no install
indicator light
identify the SIM
properly: Power off
turns off
card.
the socket and check
The power switch is
it again.
OFF.
Power on the socket.
Socket
No power input.
Check TUTA S30’s
output
The power switch is
external AC power is
cannot be
OFF.
available.
changed by
Power on the socket.
M button.
54
TUTA S30 GSM POWER SOCKET USER MANUAL
No.
General
Possible Reason
Solution
Trouble
4
5
All functions
Caller ID
Contact network
disable
presentation do not
provider to active SIM
(Indicator is
active, insufficient
card function. Pay for
working)
fee of the SIM card.
the card.
Socket didn’t
TUTA S30 work
Switch off the power,
response of
abnormally.
check SIM card, or
any
reset factory setting.
operation.
6
After power
Network signal
If mobile phone’s
on the
weak or network
signal is weak too,
socket, GSM
busy.
place the socket at
indicator
other place with
keeps
strong signal and try
flashing.
again.
55
TUTA S30 GSM POWER SOCKET USER MANUAL
No.
General
Possible Reason
Solution
Trouble
SIM card PIN code
Close the PIN code.
actives.
SIM card invalid.
Contact with local
operator to check of it.
7
The master
Other master is
Change Master
number
already set in the
number or recover to
already
socket.
factory default setting.
Invalid command.
Refer to the user
exists.
8
Invalid
format.
manual.
Please check
and try
again.
9
No
Use the Master
authorization
mobile phone to try
user
the command again.
Note: If the problem can’t be solved with above guidelines, contact to your local
distributor or after service center.
56
TUTA S30 GSM POWER SOCKET USER MANUAL
Chapter 6 Main Technical Parameters
Input power socket
110~230V/50HZ,
CEE 7/7 hybrid Schuko/French plug
Output power socket
110~ 230V/50HZ, 230V/30A(30s),
16A long-duration,
CEE7/4 German “Schuko”
Operating temperature
-10℃~+50℃
Store temperature
-20℃~+60℃
Relative humidity
10-90%,without condensation
Communication
GSM PHASE 2/2+
protocols
(including data operation)
Data interface
GSM SIM 1.8V/3.0V socket
External temperature
-10℃~50℃
sensor
GSM working band
EGSM900,DCS1800
57
TUTA S30 GSM POWER SOCKET USER MANUAL
Appendix: SMS commands list
Category
Function
Command
Time
Regulate the socket
time
(1)
#152#SIMCardNumber#
Define the
Add a master number
users
to the socket
58
(2) #00#
TUTA S30 GSM POWER SOCKET USER MANUAL
Category
Function
Command
Change the master
(3)
user’s number
#14#NewMasterNumber#
Add a family number
(4) #06#FamilyNumber#
Add several family
(5) #06#FamilyNumber1#
numbers
...#FamilyNumber4#
Delete a family
number
(6)
#113#FamilyNumber#
Delete several family
numbers
(7)
#113#FamilyNumber1#…
simultaneously
#FamilyNumber4#
Delete all family
(8) #113#
numbers
Change the password
(9) #04#Oldpassword#
Newpassword#
Switching
Master user switches
on/off output
on the socket output
manually
manually
Master user cuts off
the socket output
59
(10) #01#
(11)#02#
TUTA S30 GSM POWER SOCKET USER MANUAL
Category
Function
Command
manually
Family user switches
(12) #01#Password#
on the socket output
manually
Family user cuts off
(13) #02#Password#
the socket output
manually
Enable switching
(14) #18#1#
on/off the output by
calling
Disable switching
(15) #18#0#
on/off the output by
calling (Default)
Delay control
Delay switching on the
output after a certain
minutes
60
(16) #138#1#Minutes#
TUTA S30 GSM POWER SOCKET USER MANUAL
Category
Function
Command
Delay switching off the
(17) #138#0#Minutes#
output after a certain
minutes
Timing
Enable timing switch
control
on the output
(18) #128#1#
Set time period to
(19) #129#WorkDay#
switch on the output
StartTime#EndTime#
Disable timing switch
(20) #128#0#
on the output
Temperature
Enable auto-control
control
the output by
(21) #159#1#
temperature
Set temperature range
to switch on/off the
(22)
#159#Mode#LowTemp#
output
HighTemp#
Disable auto-control
(23) #159#0#
the output by
temperature
Over-
Enable the over61
(24) #170#1#
TUTA S30 GSM POWER SOCKET USER MANUAL
Category
Function
temperature
temperature alarm
alarm
Command
Set limits of
(25) #170#MinTemp#
temperature
MaxTemp#
Disable the over-
(26) #170#0#
temperature alarm
Temperature
Enable the
(27) #160#1#
rapid-
temperature rapid-
changing
changing alarm
alarm
Set time period and
(28) #160#Temp#Time#
temperature changing
value
Disable the
(29) #160#0#
temperature rapidchanging alarm
SMS notification upon
SMS
notification
(30) #11#1#
the socket output
changing (Default)
No SMS notification
62
(31) #11#0#
TUTA S30 GSM POWER SOCKET USER MANUAL
Category
Function
Command
upon the socket output
changing
SMS notification upon
(32) #12#1#
the power supply
changing (Default)
No SMS notification
(33) #12#0#
upon the power supply
changing
“Beep”
Enable the “Beep”
warning tone
warning tone
Disaable the “Beep”
(34) #19#1#
(35) #19#0#
warning tone (Default)
Check status
Check socket
operating status
63
(36) #07#
TUTA S30 GSM POWER SOCKET USER MANUAL
Category
Function
Command
Check Socket output
(37) #000#
status
Check “Delayed switch
(38) #138#
on/off the socket”
parameters
Check “Timed switch
(39) #128#
on the socket”
parameters
Check “Temperature
(40) #159#
control” parameters
Check “temperature
(41) #160#
rapid-changing alarm”
parameters
Check “over-
(42) #170#
temperature alarm”
parameters
Reset to factory
Reset the socket
settings
64
(43) #08#
TUTA S30 GSM POWER SOCKET USER MANUAL
TUTA S30
GSM Power Socket
65
TUTA S30 GSM POWER SOCKET USER MANUAL
E1046
66