Download Arbitrary Function Generator

Transcript
REMOTE INTERFACE
4. Press Parity/Bits (F2) and
choose a parity (F1)~(F3).
Press return.
Configure GPIB interface
GPIB
configuration
GPIB constraints
Connector
24 pin Female
GPIB address
1-30

Maximum 15 devices altogether, 20m cable
length, 2m between each device

Unique address assigned to each device

At least 2/3 of the devices turned On

No loop or parallel connection
Pin assignment
Pin1
Pin2
Pin3
Pin4
Pin5
Pin6
Pin7
Pin8
Pin9
Pin10
Pin11
Pin12
Panel Operation
12
1
24
13
Data line 1
Data line 2
Data line 3
Data line 4
EOI
DAV
NRFD
NDAC
IFC
SRQ
ATN
Shield (screen)
Pin13
Pin14
Pin15
Pin16
Pin17
Pin18
Pin19
Pin20
Pin21
Pin22
Pin23
Pin24
Data line 5
Data line 6
Data line 7
Data line 8
REN
Ground
Ground
Ground
Ground
Ground
Ground
Signal ground
1. Connect the GPIB cable to
the rear panel GPIB port.
185