Download SEBA - TERM
Transcript
SEBA HYDROMETRIE, user manual that also the remaining water drops will be removed from the supply tube of the pressure sensor. After confirmation a window opens, in which the actual zero point of the water level value continuously will be indicated. If the indication is stable, the status will be stored with “ok”. The so received values will be taken for the zero point correction of the sensor. At last insert the required hanging depth as rated value in the window “offset”-calibration. As a result the parameter will automatically be calculated, that after installation of the probe the negative tapping value arises. By installation in the field, the probe will be lowered as far as the requested tapping value has been arrived, which before had been measured with an electric contact meter. 2.8.2.3.3 Water level above normal zero or other reference point The sensor will be adjusted, that the outputted water level corresponds to the height of the water level above normal zero or another reference height. zero-point, for example top of well 700m above sea level tapping water level, (for example 20m) a) entry sebaterm 680m (probe installed) water level displayed value 680m depth of MPS-D (for example 30m) b) entry sebaterm 670m (probe not installed) installation position probe 670m above s.l. pic: 2.8.2.3.3 It’s different, whether the probe is in installation position or not. The installed probe would be the ideal status for an automatic set up. Nevertheless this is only possible if the connection cable of the probe ends freely at the top and therefore can be connected to the PC-adapter for set up in installed condition. a) Probe is in installation position For set up o the pressure measurement, the water level above normal zero must be known, resp. must be measured and has to be inserted into the window “offset-calibration”. After confirmation with "OK" the new values will be transferred to the probe. For control purposes the water level above normal zero will be indicated. b) Probe is not installed The probe has to be held in vertical position outside the medium. We recommend to shake slightly, so that also the remaining water drops will be removed from the supply tube of the pressure sensor. After confirmation a window opens, in which the actual zero point of the water level value continuously will be displayed. If the indication is stable, the status will be stored with “ok”. The so received values will be taken for the zero point correction of the sensor. At last insert the zero point above normal zero or any other reference of the intended probe position height in [m] unit as rated value in the window “offset- - 21/48 -