GS-DPA-UM-151
GS-DPA
For GL100
Adapter for Branch adapter
USER’S MANUAL
Thank you very much for buying this GRAPHTEC product.
This module can be used as a measurement adapter (hereafter
“module”) that connects to the GL100-N/GL100-WL.
These directions describe preparations and cautions before
measurement.
To ensure safety, please read the operation instructions, etc.
For details on the warnings and how to handle this module, please
read the Quick Start Guide or USER'S MANUAL included on the
CD-ROM (included in the GL100 packaging)
2 Specifications
Item
Number of connectors
Connectable sensor
Cable length
Usage environment
External dimensions
[W×D×H] (approximate)
Weight (approximate)
2. Combined CO2 sensor and temperature and humidity
sensor measurement
Contents
2 channels
Temperature and humidity sensor (GS-TH)
Illumination / ultraviolet sensor (GS-LXUV)
CO2 sensor (GS-CO2)
approximate 20 cm
-10 to 50°C, 80% RH or less (non-condensing)
46 × 66 × 27.4 mm (not including protruding parts)
Composite measurement can be done by using the CO2 sensor (GS-CO2)
and the temperature and humidity sensor (GS-TH) (each sold separately).
CO2 Sensor
(GS-CO2)
If the CO2 sensor (GS-CO2) is included in the assembly, it
cannot be powered with batteries.
Temperature and
humidity sensor
(GS-TH)
3 Connectable Sensor
1. Combined illumination / ultraviolet sensor and temperature
and humidity sensor measurement
CO2 Sensor
(GS-CO2)
* The Gl100’s power
is provided through
a USB cable
GL100 main module
connection
Branch adapter for GS
(GS-DPA)
* The Gl100’s power
is provided through
a USB cable
GL100 main module
connection
It is not possible to be used by connecting two same
sensors.
Confirmation of the exterior
Branch adapter for GS
(GS-DPA)
After opening the package, please confirm that there are no
problems (scratches and dirt) on the exterior before use.
Confirmation of the attached items.
•User’s manual (this book): 1
GL100 main module
If by any chance faults are found, please contact the store where you
bought the item.
* Please note that items mentioned in this book may change without
prior notice.
604309191
MANUAL-ADD
1 Part Names
This section describes the name and function of each part.
1. Hook portion
It is not possible to be used by connecting two same
sensors.
(1) Screen display menu flow
After power-on, the GL100 is ready for operation by holding down [MENU] key.
When the module is connected, “Module Type Recognition” screen is displayed.
When the module is not connected, “Module Unconnected State” screen is
displayed.
Operate in accordance with the displayed instructions.
SENSOR ERROR!! Please connect the sensor QUIT key to Power Off
BAT LAN Module unconnected state
Recognition of module types
”Please wait” 2. Sensor connector
3. Connector
QUIT key to Power Off
BAT LAN GL100-TH+LX Initializing!! 4. Cable packing
GL100 main module
1. Wall mounting hole ....... Used to mount to a wall.
2. Sensor connector ......... The sensor connectors are on the left and right.
3. Connector ..................... Used to connect to the connector on the
GL100 module.
4. Cable packing ............... This packing is used when connecting the connector.
GL100 has basic water protection but this module
• The
has no water protection. Be careful when installing and
•
•
•
handling.
Before connecting to the GL100, always connect all of
the sensors to the branch adapter and then connect.
When using the CO2 sensor in combination with other sensors,
always use a USB cable connection as the power source.
The sensor connector is used for GS-LXUV, GS-CO2 or GS-TH only.
Please do not connect the device other than them.
The GL100-N/GL100-WL may be damaged.
< Extension cable >
The module can be used approx. 1.5 m away from the GL100 by using an
extension cable for GS (GS-EXC). However, you cannot connect and use multiple
extension cables.
CAUTION
It is not possible to be used by connecting two same sensors.
STOP ALM. 1:28
TEMP: +26.16℃
HUM.: +37.3%
ILLUM: 440 lx
m UV-A: 0.030 W
BAT LAN SD S: 1.0s
Standby state
TEMP: +26.16℃
HUM.: +37.3%
DEWP: +10.30℃
PP
CO2: 736 m
Module start-up
BAT LAN SD S: 1.0s
Hold down the [QUIT] key (approx. three seconds)
to put the module into standby state.
When running on batteries, the module will
automatically go into standby state after three
minutes of no operation.
Press the [ENTER] key while in standby state to
return to the free-running screen.
AMP input condition settings
Range
ILLUM.
2000, 20000, 200000 lx
Standby state
<Operation>
Press [ENTER] key.
Module start-up
Measurements of three sensors are displayed in the screen.
You can switch to the Accumulation screen with the and keys when
recording data.
REC. ALM. 1:28
REC. ALM. 1:28
DEWP: +29.75℃
ACCUM.TEMP: 2650℃h
ACCUM.ILLUM: 2410k lx
ACCUM.UV-A: m 0.030 h
W Accumulation display (1)
Accumulation display (2)
BAT LAN SD S: 1.0s
After power-on, the GL100 is ready for operation by holding down [MENU] key.
When the module is connected, “Module Type Recognition” screen is displayed.
When the module is not connected, “Module Unconnected State” screen is
displayed.
Operate in accordance with the displayed instructions.
SENSOR ERROR!! Please connect the sensor QUIT key to Power Off
BAT LAN Module unconnected state
Recognition of module types
”Please wait” <Operation>
Connect the module.
GL100-CO2+LX Sleeping!! ENTER key to start QUIT key to Power Off
BAT LAN GL100-CO2+LX Initializing!! Standby state
<Operation>
Press [ENTER] key.
Module start-up
(2) Free-running screen
Hold down the [QUIT] key (approx. three seconds)
to put the module into standby state.
Press the [ENTER] key while in standby state to
return to the free-running screen.
For the settings, refer to USER’S MANUAL of each module.
(4) Recording
Press the [START/STOP] key to start measuring with the set conditions.
REC. ALM. 1:28
REC. ALM. 1:28
TEMP: +26.16℃
HUM.: +37.3%
DEWP: +10.30℃
PP
CO2: 736 m
DEWP: +29.75℃
ACCUM.TEMP: 2650℃h
Normal display
(1) Screen display menu flow
(3) Setting
BAT LAN SD S: 1.0s
It is not possible to be used by connecting two same
sensors.
Measurements of two sensors are displayed in the screen.
You can switch to the Accumulation screen with the and keys when
recording data.
Press the [START/STOP] key to start measuring with the set conditions.
Normal display
STOP ALM. 1:28
(4) Recording
BAT LAN SD S: 1.0s
Recognition of module types
”Please wait” (2) Free-running screen
<Operation>
Press [ENTER] key.
For other settings, refer to USER’S MANUAL of each module.
TEMP: +26.16℃
HUM.: +37.3%
ILLUM: 440 lx
m UV-A: 0.030 W
<Operation>
Connect the module.
AMP settings can be set in this combination.
REC. ALM. 1:28
Module unconnected state
(3) Setting
[AMP] 1/9
TEMP. Range:-20~+80℃ HUM. Range:0~100%RH UV-A Range:30mW/cm 2 ILLUM. Range: 200000lx▽ SENSOR ERROR!! Please connect the sensor QUIT key to Power Off
BAT LAN GL100-CO2+TH Initializing!! (2) Free-running screen
After power-on, the GL100 is ready for operation by holding down [MENU] key.
When the module is connected, “Module Type Recognition” screen is displayed.
When the module is not connected, “Module Unconnected State” screen is
displayed.
Operate in accordance with the displayed instructions.
QUIT key to Power Off
BAT LAN GL100-TH+LX Sleeping!! ENTER key to start (1) Screen display menu flow
GL100-CO2+TH Sleeping!! ENTER key to start <Operation>
Connect the module.
Illumination /
Ultraviolet sensor
(GS-LXUV)
Branch adapter for GS
(GS-DPA)
Composite measurement can be done by using the illumination / ultraviolet
sensor (GS-LXUV) and the temperature and humidity sensor (GS-TH)
(each sold separately).
Temperature and
humidity sensor
(GS-TH)
Composite measurement can be done by using the CO2 sensor (GS-CO2)
and the illumination / ultraviolet sensor (GS-LXUV) (each sold separately).
If the CO2 sensor (GS-CO2) is included in the assembly, it
cannot be powered with batteries.
68 g
Illumination /
Ultraviolet sensor
(GS-LXUV)
3. Combined CO2 sensor and illumination / ultraviolet sensor
BAT LAN SD S: 1.0s
Accumulation display
STOP ALM. 1:28
ILLUM: 440 lx
m UV-A: 0.030 W
PP
CO2: 736 m
BAT LAN SD S: 1.0s
Hold down the [QUIT] key (approx. three seconds)
to put the module into standby state.
Press the [ENTER] key while in standby state to
return to the free-running screen.
(3) Setting
AMP settings can be set in this combination.
[AMP] 1/9
CO2. Range:9999ppm UV-A Range:30mW/cm 2 ILLUM. Range: 200000lx▽ AMP input condition settings
Range
ILLUM.
2000, 20000, 200000 lx
For other settings, refer to USER’S MANUAL of each module.
(4) Recording
Press the [START/STOP] key to start measuring with the set conditions.
Measurements of two sensors are displayed in the screen.
You can switch to the Accumulation screen with the and keys when
recording data.
REC. ALM. 1:28
ILLUM: 440 lx
m UV-A: 0.030 W
PP
CO2: 736 m
BAT LAN SD S: 1.0s
Normal display
REC. ALM. 1:28
ACCUM.ILLUM: 2410k lx
ACCUM.UV-A: m 0.030 h
W BAT LAN SD S: 1.0s
Accumulation display
BAT LAN SD S: 1.0s
503-10 Shinano-cho, Totsuka-ku Yokohama
244-8503, Japan
August 1, 2014