Transcript
GS-DPA-UM-151 GS-DPA For GL100 Adapter for Branch adapter USER’S MANUAL Thank you very much for buying this GRAPHTEC product. This module can be used as a measurement adapter (hereafter “module”) that connects to the GL100-N/GL100-WL. These directions describe preparations and cautions before measurement. To ensure safety, please read the operation instructions, etc. For details on the warnings and how to handle this module, please read the Quick Start Guide or USER'S MANUAL included on the CD-ROM (included in the GL100 packaging) 2 Specifications Item Number of connectors Connectable sensor Cable length Usage environment External dimensions [W×D×H] (approximate) Weight (approximate) 2. Combined CO2 sensor and temperature and humidity sensor measurement Contents 2 channels Temperature and humidity sensor (GS-TH) Illumination / ultraviolet sensor (GS-LXUV) CO2 sensor (GS-CO2) approximate 20 cm -10 to 50°C, 80% RH or less (non-condensing) 46 × 66 × 27.4 mm (not including protruding parts) Composite measurement can be done by using the CO2 sensor (GS-CO2) and the temperature and humidity sensor (GS-TH) (each sold separately). CO2 Sensor (GS-CO2) If the CO2 sensor (GS-CO2) is included in the assembly, it cannot be powered with batteries. Temperature and humidity sensor (GS-TH) 3 Connectable Sensor 1. Combined illumination / ultraviolet sensor and temperature and humidity sensor measurement CO2 Sensor (GS-CO2) * The Gl100’s power is provided through a USB cable GL100 main module connection Branch adapter for GS (GS-DPA) * The Gl100’s power is provided through a USB cable GL100 main module connection It is not possible to be used by connecting two same sensors. Confirmation of the exterior Branch adapter for GS (GS-DPA) After opening the package, please confirm that there are no problems (scratches and dirt) on the exterior before use. Confirmation of the attached items. •User’s manual (this book): 1 GL100 main module If by any chance faults are found, please contact the store where you bought the item. * Please note that items mentioned in this book may change without prior notice. 604309191 MANUAL-ADD 1 Part Names This section describes the name and function of each part. 1. Hook portion It is not possible to be used by connecting two same sensors. (1) Screen display menu flow After power-on, the GL100 is ready for operation by holding down [MENU] key. When the module is connected, “Module Type Recognition” screen is displayed. When the module is not connected, “Module Unconnected State” screen is displayed. Operate in accordance with the displayed instructions. SENSOR ERROR!! Please connect the sensor QUIT key to Power Off BAT LAN Module unconnected state Recognition of module types ”Please wait” 2. Sensor connector 3. Connector QUIT key to Power Off BAT LAN GL100-TH+LX Initializing!! 4. Cable packing GL100 main module 1. Wall mounting hole ....... Used to mount to a wall. 2. Sensor connector ......... The sensor connectors are on the left and right. 3. Connector ..................... Used to connect to the connector on the GL100 module. 4. Cable packing ............... This packing is used when connecting the connector. GL100 has basic water protection but this module • The has no water protection. Be careful when installing and • • • handling. Before connecting to the GL100, always connect all of the sensors to the branch adapter and then connect. When using the CO2 sensor in combination with other sensors, always use a USB cable connection as the power source. The sensor connector is used for GS-LXUV, GS-CO2 or GS-TH only. Please do not connect the device other than them. The GL100-N/GL100-WL may be damaged. < Extension cable > The module can be used approx. 1.5 m away from the GL100 by using an extension cable for GS (GS-EXC). However, you cannot connect and use multiple extension cables. CAUTION It is not possible to be used by connecting two same sensors. STOP ALM. 1:28 TEMP: +26.16℃ HUM.: +37.3% ILLUM: 440 lx m UV-A: 0.030 W BAT LAN SD S: 1.0s Standby state TEMP: +26.16℃ HUM.: +37.3% DEWP: +10.30℃ PP CO2: 736 m Module start-up BAT LAN SD S: 1.0s Hold down the [QUIT] key (approx. three seconds) to put the module into standby state. When running on batteries, the module will automatically go into standby state after three minutes of no operation. Press the [ENTER] key while in standby state to return to the free-running screen. AMP input condition settings Range ILLUM. 2000, 20000, 200000 lx Standby state <Operation> Press [ENTER] key. Module start-up Measurements of three sensors are displayed in the screen. You can switch to the Accumulation screen with the and keys when recording data. REC. ALM. 1:28 REC. ALM. 1:28 DEWP: +29.75℃ ACCUM.TEMP: 2650℃h ACCUM.ILLUM: 2410k lx ACCUM.UV-A: m 0.030 h W Accumulation display (1) Accumulation display (2) BAT LAN SD S: 1.0s After power-on, the GL100 is ready for operation by holding down [MENU] key. When the module is connected, “Module Type Recognition” screen is displayed. When the module is not connected, “Module Unconnected State” screen is displayed. Operate in accordance with the displayed instructions. SENSOR ERROR!! Please connect the sensor QUIT key to Power Off BAT LAN Module unconnected state Recognition of module types ”Please wait” <Operation> Connect the module. GL100-CO2+LX Sleeping!! ENTER key to start QUIT key to Power Off BAT LAN GL100-CO2+LX Initializing!! Standby state <Operation> Press [ENTER] key. Module start-up (2) Free-running screen Hold down the [QUIT] key (approx. three seconds) to put the module into standby state. Press the [ENTER] key while in standby state to return to the free-running screen. For the settings, refer to USER’S MANUAL of each module. (4) Recording Press the [START/STOP] key to start measuring with the set conditions. REC. ALM. 1:28 REC. ALM. 1:28 TEMP: +26.16℃ HUM.: +37.3% DEWP: +10.30℃ PP CO2: 736 m DEWP: +29.75℃ ACCUM.TEMP: 2650℃h Normal display (1) Screen display menu flow (3) Setting BAT LAN SD S: 1.0s It is not possible to be used by connecting two same sensors. Measurements of two sensors are displayed in the screen. You can switch to the Accumulation screen with the and keys when recording data. Press the [START/STOP] key to start measuring with the set conditions. Normal display STOP ALM. 1:28 (4) Recording BAT LAN SD S: 1.0s Recognition of module types ”Please wait” (2) Free-running screen <Operation> Press [ENTER] key. For other settings, refer to USER’S MANUAL of each module. TEMP: +26.16℃ HUM.: +37.3% ILLUM: 440 lx m UV-A: 0.030 W <Operation> Connect the module. AMP settings can be set in this combination. REC. ALM. 1:28 Module unconnected state (3) Setting [AMP] 1/9 TEMP. Range:-20~+80℃ HUM. Range:0~100%RH UV-A Range:30mW/cm 2 ILLUM. Range: 200000lx▽ SENSOR ERROR!! Please connect the sensor QUIT key to Power Off BAT LAN GL100-CO2+TH Initializing!! (2) Free-running screen After power-on, the GL100 is ready for operation by holding down [MENU] key. When the module is connected, “Module Type Recognition” screen is displayed. When the module is not connected, “Module Unconnected State” screen is displayed. Operate in accordance with the displayed instructions. QUIT key to Power Off BAT LAN GL100-TH+LX Sleeping!! ENTER key to start (1) Screen display menu flow GL100-CO2+TH Sleeping!! ENTER key to start <Operation> Connect the module. Illumination / Ultraviolet sensor (GS-LXUV) Branch adapter for GS (GS-DPA) Composite measurement can be done by using the illumination / ultraviolet sensor (GS-LXUV) and the temperature and humidity sensor (GS-TH) (each sold separately). Temperature and humidity sensor (GS-TH) Composite measurement can be done by using the CO2 sensor (GS-CO2) and the illumination / ultraviolet sensor (GS-LXUV) (each sold separately). If the CO2 sensor (GS-CO2) is included in the assembly, it cannot be powered with batteries. 68 g Illumination / Ultraviolet sensor (GS-LXUV) 3. Combined CO2 sensor and illumination / ultraviolet sensor BAT LAN SD S: 1.0s Accumulation display STOP ALM. 1:28 ILLUM: 440 lx m UV-A: 0.030 W PP CO2: 736 m BAT LAN SD S: 1.0s Hold down the [QUIT] key (approx. three seconds) to put the module into standby state. Press the [ENTER] key while in standby state to return to the free-running screen. (3) Setting AMP settings can be set in this combination. [AMP] 1/9 CO2. Range:9999ppm UV-A Range:30mW/cm 2 ILLUM. Range: 200000lx▽ AMP input condition settings Range ILLUM. 2000, 20000, 200000 lx For other settings, refer to USER’S MANUAL of each module. (4) Recording Press the [START/STOP] key to start measuring with the set conditions. Measurements of two sensors are displayed in the screen. You can switch to the Accumulation screen with the and keys when recording data. REC. ALM. 1:28 ILLUM: 440 lx m UV-A: 0.030 W PP CO2: 736 m BAT LAN SD S: 1.0s Normal display REC. ALM. 1:28 ACCUM.ILLUM: 2410k lx ACCUM.UV-A: m 0.030 h W BAT LAN SD S: 1.0s Accumulation display BAT LAN SD S: 1.0s 503-10 Shinano-cho, Totsuka-ku Yokohama 244-8503, Japan August 1, 2014