Download User Guide - Beckman Coulter

Transcript
User Guide
Avanti JXN Series
High Performance Centrifuges
For In Vitro Diagnostic Use
Rx Only
PN B38322AB
October 2014
Beckman Coulter, Inc.
250 S. Kraemer Blvd.
Brea, CA 92821 U.S.A.
Avanti JXN
High Performance Centrifuges
User Guide
PN B38322AB (February 2014)
© 2014 Beckman Coulter, Inc.
All Rights Reserved
Avanti, Beckman Coulter, and the stylized logo are
trademarks of Beckman Coulter, Inc. and are registered in
the USPTO.
All other trademarks, service marks, products, or services
are trademarks or registered trademarks of their
respective holders.
Find us on the World Wide Web at:
www.beckmancoulter.com
Printed in USA
Beckman Coulter Ireland, Inc.
Mervue Business Park, Mervue Galway, Ireland 353 91 774068
Revision History
Revision AB, 10/2014
Table 1.2, Available Rotors- Removed JLA-10.500 entries for JXN-30 Max RPM, and JXN-30 Max RCF;
Removed JS-5.9 Swinging Bucket Rotor.
Initial Issue, 02/2014
Avanti JXN-26
Avantii JXN-30
Initial Release
This document applies to the latest software listed and higher versions. When a subsequent software
version affects the information in this document, a new issue will be released to the Beckman Coulter Web
site. For labeling updates, go to www.beckmancoulter.com and download the latest version of the manual
or system help for your instrument.
PN B38322AB
iii
Revision History
iv
PN B38322AB
Safety Notice
Read all product manuals and consult with Beckman Coulter-trained personnel before attempting
to operate instrument. Do not attempt to perform any procedure before carefully reading all
instructions. Always follow product labeling and manufacturer’s recommendations. If in doubt as
to how to proceed in any situation, contact your Beckman Coulter Representative.
Beckman Coulter, Inc. urges its customers and employees to comply with all national health and
safety standards such as the use of barrier protection. This may include, but is not limited to,
protective eyewear, gloves, and suitable laboratory attire when operating or maintaining this or
any other automated laboratory analyzer.
Alerts for Danger, Warning, Caution, Important, and Note
DANGER
DANGER indicates an imminently hazardous situation which, if not avoided, will
result in death or serious injury.
WARNING
WARNING indicates a potentially hazardous situation which, if not avoided, could
result in death or serious injury. May be used to indicate the possibility of
erroneous data that could result in an incorrect diagnosis.
CAUTION
CAUTION indicates a potentially hazardous situation, which, if not avoided, may
result in minor or moderate injury. It may also be used to alert against unsafe
practices. May be used to indicate the possibility of erroneous data that could
result in an incorrect diagnosis.
IMPORTANT IMPORTANT is used for comments that add value to the step or procedure being performed.
Following the advice in the Important adds benefit to the performance of a piece of equipment or to a
process.
NOTE NOTE is used to call attention to notable information that should be followed during installation, use,
or servicing of this equipment.
PN B38322AB
v
Safety Notice
Alerts for Danger, Warning, Caution, Important, and Note
WARNING
Risk of operator injury if:
• All doors, covers, and panels are not closed and secured in place prior to and
during instrument operation.
• The integrity of safety interlocks and sensors is compromised.
• Instrument alarms and error messages are not acknowledged and acted upon.
• You contact moving parts.
• You mishandle broken parts.
• Doors, covers, and panels are not opened, closed, removed, and/or replaced
with care.
• Improper tools are used for troubleshooting.
To avoid injury:
• Keep doors, covers, and panels closed and secured in place while the
instrument is in use.
• Take full advantage of the safety features of the instrument. Do not defeat
safety interlocks and sensors.
• Acknowledge and act upon instrument alarms and error messages.
• Keep away from moving parts.
• Report any broken parts to your Beckman Coulter Representative.
• Open/remove and close/replace doors, covers, and panels with care.
• Use the proper tools when troubleshooting.
CAUTION
System integrity could be compromised and operational failures could occur if:
• This equipment is used in a manner other than specified. Operate the
instrument as instructed in the Product Manuals.
• You introduce software that is not authorized by Beckman Coulter into your
computer. Only operate your system’s computer with software authorized by
Beckman Coulter.
• You install software that is not an original copyrighted version. Only use
software that is an original copyrighted version to prevent virus
contamination.
CAUTION
If you purchased this product from anyone other than Beckman Coulter or an
authorized Beckman Coulter distributor, and, it is not presently under a Beckman
Coulter service maintenance agreement, Beckman Coulter cannot guarantee that
the product is fitted with the most current mandatory engineering revisions or
that you will receive the most current information bulletins concerning the
vi
PN B38322AB
Safety Notice
Safety Notices
product. If you purchased this product from a third party and would like further
information concerning this topic, contact your Beckman Coulter Representative.
Safety Notices
Before installing, using, or maintaining the instrument, be certain that you know all the following
precautions.
Installation
CAUTION
This instrument is designed to be installed by your Beckman Coulter
Representative. Installation by anyone other than authorized Beckman Coulter
personnel invalidates any warranty covering the instrument. Also, should the
instrument need to be moved, your Beckman Coulter Representative must
reinstall and re-level the instrument in its new location.
WARNING
Do not place the centrifuge near areas containing flammable or combustible
fluids, or any other source of vapors that could enter the centrifuge air system and
be ignited by the motor.
WARNING
Risk of operator injury. High performance centrifuge operations generate high
energy levels that require precautions against sudden movements that could
result from the rare event of a rotor failure. Maintain a 30-cm (1-ft) clearance
envelope around and above the centrifuge. Do not install any equipment or
furniture in this envelope. While the centrifuge is running, keep the envelope clear
of any persons or objects and do not reach into the envelope except when required
to change operating controls.
Replacement Parts
CAUTION
Risk of rotor mishap and/or improper instrument function. Do not replace any
centrifuge components with parts not specified for use on this instrument.
PN B38322AB
vii
Safety Notice
Safety Notices
Service
WARNING
Any servicing of this equipment that requires removal of any covers can expose
parts which involve the risk of electric shock or personal injury. Make sure that the
power switch is turned off, and the instrument is disconnected from the main
power source, by removing its power plug from the receptacle. Refer such
servicing to qualified personnel.
NOTE It is your responsibility to decontaminate the instrument and accessories before requesting service by
your Beckman Coulter Representative.
Power Supply
DANGER
To reduce the risk of electrical shock, this instrument uses a three-wire electrical
cord and plug to connect this equipment to earth-ground. Make sure that the
matching wall outlet receptacle is properly wired and earth-grounded.
Fuse Replacement
WARNING
Fuses protect certain electrical circuits within this instrument against overcurrent
conditions. The fuse is not customer replaceable. For continued protections,
please contact your Beckman Coulter Representative.
viii
PN B38322AB
Safety Notice
Safety Notices
Mechanical Safety
DANGER
For safe operation of the equipment, observe the following:
• Use only the Beckman Coulter rotors and accessories designed for use in this
instrument.
• Do not exceed the maximum rated speed of the rotor in use.
• NEVER attempt to slow or stop a rotor by hand.
• Do not move the centrifuge while the drive motor is spinning.
• NEVER attempt to override the door interlock system.
• Do not lean on the centrifuge or place items on it while it is operating.
• In the event of a power failure, do not attempt to retrieve the sample from the
instrument until the rotor has come to a complete stop. The time required for
a rotor to come to a complete stop can vary from 1 to 9 hours depending upon
the set speed while in operation and the rotor’s mass. Then follow the
instructions for recovery of the sample in the Maintenance and
Troubleshooting chapter.
Chemical and Biological Safety
DANGER
Normal operation may involve the use of solutions and test samples that are
pathogenic, toxic, or radioactive. Such materials require that you take all
necessary safety precautions.
• Handle body fluids with care because they can transmit disease. No known
test offers complete assurance that they are free of micro-organisms.
• Handle all infectious samples according to good laboratory procedures and
methods to prevent spread of disease.
• Because spills may generate aerosols, observe proper safety precautions for
aerosol containment.
• Some of the most virulent infectious agents — Hepatitis (B and C) and HIV (I-V)
viruses, atypical mycobacteria, and certain systemic fungi — require
additional emphasis on aerosol protection.
• Do not run toxic, pathogenic, or radioactive materials in a rotor without taking
appropriate safety precautions.
• Risk Group II materials (as identified in the World Health Organization
Laboratory Biosafety Manual) require biosafe containment. Materials of a
higher group require more than one level of protection.
• Dispose of all waste solutions according to appropriate environmental health
and safety guidelines.
PN B38322AB
ix
Safety Notice
Summary of Instrument Labels
Precautions with Liquids
CAUTION
Risk of instrument damage. Do not place containers holding liquid on or near the
chamber door. Liquid, if spilled, may get into the instrument and damage
electrical or mechanical components.
Volatile Liquids
DANGER
This instrument is not designed for use with materials capable of developing
flammable or explosive vapors. Do not centrifuge such materials (for example,
chloroform or ethyl alcohol) in this instrument nor handle or store them near the
centrifuge.
Summary of Instrument Labels
This section provides information for some labels and symbols appearing on the Avanti JXN series
instrument housing. These labels and symbols may be associated with user-serviceable procedures.
Individual hazards associated with a specific procedure in this manual may use these labels and
symbols, and are included in Warnings or Cautions within the procedures for that task.
Caution Symbol
!
This symbol indicates a caution message and appears adjacent to an explanation or other symbols
that define the caution. Please consult the User Guide to determine the nature of the potential
hazard and any necessary actions to be taken.
RoHS Notice
These labels and materials declaration table (the Table of Hazardous Substance’s Name and
Concentration) are to meet People’s Republic of China Electronic Industry Standard SJ/T11364-2006
“Marking for Control of Pollution Caused by Electronic Information Products” requirements.
x
PN B38322AB
Safety Notice
Summary of Instrument Labels
China RoHS Caution Label
This label indicates that the electronic information product contains certain toxic or hazardous
substances. The center number is the Environmentally Friendly Use Period (EFUP) date, and
indicates the number of calendar years the product can be in operation. Upon the expiration of the
EFUP, the product must be immediately recycled. The circling arrows indicate the product is
recyclable. The date code on the label or product indicates the date of manufacture.
China RoHS Environmental Label
This label indicates that the electronic information product does not contain any toxic or hazardous
substances. The center “e” indicates the product is environmentally safe and does not have an
Environmentally Friendly Use Period (EFUP) date. Therefore, it can safely be used indefinitely. The
circling arrows indicate the product is recyclable. The date code on the label or product indicates
the date of manufacture.
Universal Serial Bus (USB)
This symbol indicates the location of a universal serial bus (USB) connector.
WEEE Recycling Label
A28219-AA
This symbol is required in accordance with the Waste Electrical and Electronic Equipment (WEEE)
Directive of the European Union. The presence of this marking on the product indicates:
• the device was put on the European Market after August 13, 2005 and
PN B38322AB
xi
Safety Notice
Summary of Instrument Labels
• the device is not to be disposed of via the municipal waste collection system of any member
state of the European Union.
It is very important that customers understand and follow all laws regarding the proper
decontamination and safe disposal of electrical equipment. For Beckman Coulter products bearing
this label, please contact your dealer or local Beckman Coulter office for details on the take-back
program that will facilitate the proper collection, treatment, recovery, recycling and safe disposal
of the device.
Multiple Compliance
This symbol indicates compliance with:
• IVD – For in vitro diagnostic use
• N395 – The C-Tick mark is intended for use on products that comply with Australian
Communication Authority (ACA) EMC Requirements.
CAUTION
This equipment has been designed and tested to CISPR 11 Class A. In a domestic
environment it could cause radio interference, in which case, you may need to
take measures to mitigate the interference.
It is advised that prior to operation of the device, the electromagnetic
environment should be evaluated. Do not use this device in close proximity to
sources of strong electromagnetic radiation (for example, unshielded intentional
RF sources), as these could interfere with proper operation.
• 169502 – This label indicates recognition by a Nationally Recognized Testing Laboratory (NRTL)
that the instrument has met the relevant product safety standards.
NOTE 169502 is applicable to North American models only.
• CE – This label indicates conformance to various Directives set forth under European Union law.
• Recycling – Refer to the Recycling Label section in this document.
xii
PN B38322AB
Safety Notice
Summary of Instrument Labels
Biohazard Warning
These caution symbols indicate biohazardous risk from possible patient specimen contamination.
CAUTION Static Sensitive Area
Indicates an area of the instrument which is sensitive to static electrostatic discharge (ESD). To
prevent damage due to electrostatic discharge, always wear a properly earth-grounded wrist strap
while operating this instrument. For details on proper grounding, see IEEE standard P1100.
DANGER High Voltage
Operation, replacement or servicing of any components where contact with bare, live hazardous
parts could occur, possibly resulting in electric shock, should only be performed by your
Beckman Coulter representative.
Protective Ground
This symbol is used to indicate a protective ground. This instrument must be properly grounded.
Do not under any circumstances operate the instrument unless it is properly grounded.
PN B38322AB
xiii
Safety Notice
Summary of Instrument Labels
Rotor Rotation
This indicates the direction of instrument rotor rotation.
xiv
PN B38322AB
Contents
Revision History, iii
Safety Notice, v
Alerts for Danger, Warning, Caution, Important, and Note, v
Safety Notices, vii
Installation, vii
Replacement Parts, vii
Service, viii
Power Supply, viii
Fuse Replacement, viii
Mechanical Safety, ix
Chemical and Biological Safety, ix
Precautions with Liquids, x
Volatile Liquids, x
Summary of Instrument Labels, x
Caution Symbol, x
RoHS Notice, x
China RoHS Caution Label, xi
China RoHS Environmental Label, xi
Universal Serial Bus (USB), xi
WEEE Recycling Label, xi
Multiple Compliance, xii
Biohazard Warning, xiii
CAUTION Static Sensitive Area, xiii
DANGER High Voltage, xiii
Protective Ground, xiii
Rotor Rotation, xiv
Introduction, xxvii
Overview, xxvii
About This Manual, xxvii
Conventions, xxviii
Certification, xxviii
Scope of Manual, xxviii
xv
Contents
CFC-Free Centrifugation, xxix
Software Copyright, xxix
Symbols, xxx
Graphics, xxxi
CHAPTER 1:
Description, 1-1
Overview, 1-1
For In Vitro Diagnostic Use, 1-1
Centrifuge Function, 1-2
Touch Screen, 1-2
Name Rating Plate, 1-2
Housing and Door, 1-3
Rotor Chamber, 1-3
Friction Reduction System (FRS), 1-3
Drive, 1-3
Temperature Sensing and Control, 1-3
Overtemp System, 1-4
Safety Features, 1-4
Specifications, 1-5
Audible Sounds, 1-7
Available Rotors, 1-7
CHAPTER 2:
The Touch Screen Interface, 2-1
Overview, 2-1
Areas on the Screen, 2-2
Header Bar, 2-2
Home Page Button, 2-2
Menu Button, 2-3
Status Display, 2-3
Help Button, 2-4
Footer Bar, 2-4
Start Button, 2-4
Stop Button, 2-5
Footer Bar on the Home Page, 2-5
Footer Bar on Other Pages, 2-5
Rotor Display/Button, 2-5
System Name, 2-6
Accel and Decel Display/Button, 2-6
Page Display Area, 2-6
Help Messages, 2-6
xvi
Contents
Item Help, 2-6
Global Help, 2-6
Exit from Help, 2-8
About Your Instrument, 2-8
CHAPTER 3:
Operations, 3-1
Overview, 3-1
Manual Operation, 3-1
Step 1: Start on the Home Page, 3-2
Step 2: Set the Speed and Rotor, 3-3
Step 3: Set the Acceleration and Deceleration Profiles, 3-4
Step 4: Set the Time, 3-6
Step 5: Set the Temperature, 3-8
Step 6: Start the Run, 3-8
Zonal and Continuous Flow Operation , 3-9
Preparing for the Run, 3-10
Starting the Run, 3-11
Loading the Sample, 3-11
Running the Sample, 3-12
Unloading the Sample, 3-12
Stopping the Run, 3-12
Finishing the Run, 3-12
CHAPTER 4:
Configuration, 4-1
Overview, 4-1
Managing Your Network , 4-1
Setting Up the Network , 4-1
Selecting a Printer, 4-2
Setting Up Email , 4-2
Setting Up VNC, 4-3
Enabling API, 4-4
Managing Users, 4-4
Adding Users, 4-5
Requiring Login, 4-5
PIN Expiration and Logout Timer, 4-6
User Options, 4-7
Managing Rotors, 4-7
Adding Rotors, 4-8
Managing Reports, 4-9
User Access, 4-9
Filtering Data, 4-10
Graphing Data, 4-12
Print Data, 4-13
Export Data, 4-14
Auto Print and Auto Export Run History Data, 4-16
xvii
Contents
Enabling Auto Print , 4-16
Enabling Auto Export, 4-16
Enabling Run Comments, 4-17
E-Signature, 4-18
CHAPTER 5:
Programs, 5-1
Overview, 5-1
Creating Programs, 5-2
Running Programs, 5-6
Editing Programs, 5-7
Deleting Programs, 5-8
CHAPTER 6:
Functional Pages, 6-1
Overview, 6-1
Home Page, 6-3
Home Page (Run in Progress), 6-5
Set Speed Page, 6-6
Select Rotor Page (Library), 6-7
Set Time Page, 6-8
Delay Start Page, 6-9
Set Speed ω²t Time Page, 6-10
Set Temperature Page, 6-11
Set Acceleration/Deceleration Profiles Page, 6-12
Example Acceleration and Deceleration Settings, 6-13
Login Page, 6-13
Select Program Page, 6-14
New/Edit/View Program Page, 6-15
Select Rotor Page (Catalog), 6-17
New/Edit Step Page, 6-18
Program Log Page, 6-19
Export Page, 6-20
Authorize Users Page, 6-21
Import Page, 6-22
Real-Time Run Data/Historical Run Data Page, 6-23
Run Graph Options Page, 6-24
Run History Page, 6-25
xviii
Contents
Run History Filter Page, 6-27
Before Run/After Run Comment Page, 6-28
Menu Page, 6-29
System Options Page, 6-30
The Basic Tab, 6-30
The System Tab, 6-31
The Network Tab, 6-32
The Users Tab, 6-33
The Reports Tab, 6-34
Select Language Page, 6-35
User Options Page, 6-36
Max Temperature Offset Page, 6-37
Reset User PIN Page, 6-38
Select Image Page, 6-39
Set Date and Time Page, 6-40
System Log Page, 6-41
Manage Rotors Page, 6-42
Add to Rotor Library Page, 6-43
Diagnostic History Page, 6-44
Set Sound Page, 6-45
Custom Sounds Page, 6-46
Archive Data Page, 6-47
Setup Network Page, 6-48
Select Printer Page, 6-49
Setup Email Page, 6-50
Setup VNC Page, 6-51
Manage Users Page, 6-52
Add/Edit User Page, 6-53
Authorize Programs Page, 6-54
Rotor Catalog Page, 6-55
About Page, 6-56
Zonal Authorization Page, 6-57
Zonal Operation Page, 6-58
CHAPTER 7:
Maintenance and Troubleshooting, 7-1
Overview, 7-1
xix
Contents
Field Service, 7-1
Maintenance, 7-1
Cleaning, 7-2
Tube Breakage, 7-3
Decontamination, 7-3
Sterilization and Disinfection, 7-4
Replacing the Air Filter, 7-4
Checking the Vacuum Pump, 7-5
Diagnostics/User Messages, 7-6
Accessing the Rotor in Case of Power Failure, 7-6
JCF-Z Rotor Identification, 7-11
Storage and Transportation, 7-11
Supply List, 7-12
Replacement Parts and Supplies, 7-12
APPENDIX A:
Preinstallation Requirements, A-1
Preinstallation Requirements, A-1
Electrical Requirements, A-1
Single and Three-Phase Power Connections, A-2
Additional Requirements for Three-Phase Power
Connections, A-4
Space and Location Requirements, A-4
Using J2 Series Rotors in the Avanti JXN Series, A-5
Checking for Rotor Drive Pins, A-5
Using the JCF-Z Continuous Flow/Zonal Rotor, A-7
Zonal Bracket Kits, A-7
APPENDIX B:
Temperature Calibration Procedure, B-1
Introduction, B-1
APPENDIX C:
Diagnostics, C-1
Overview, C-1
Diagnostics/User Messages Chart, C-1
APPENDIX D:
Third Party Contributions and Legal Notices, D-1
Contributions and Legal Notices, D-1
APPENDIX E:
HEPA Filter Replacement Instructions for the Avanti JXN
Series Centrifuges, E-1
HEPA Filter Replacement, E-1
xx
Contents
Abbreviations
Index
Beckman Coulter, Inc.
Avanti JXN Series Centrifuge Warranty
Related Documents
xxi
Illustrations
Illustrations
xxii
2.1
Home Page, 2-1
2.2
Header Bar, 2-2
2.3
Home Page Button, 2-2
2.4
Menu Button, 2-3
2.5
Ready Status, 2-3
2.6
Header Bar - Ready Status, 2-3
2.7
Header Bar - Running Status, 2-3
2.8
Header Bar - Stopping Status, 2-4
2.9
Header Bar - Warning Message, 2-4
2.10
Header Bar - Error Message, 2-4
2.11
Help Button, 2-4
2.12
Start Button, 2-4
2.13
Stop Button, 2-5
2.14
Footer Bar - Home Page, 2-5
2.15
Footer Bar on Other Pages, 2-5
2.16
Item Help Button, 2-6
2.17
Global Help Button attached to Help Button, 2-7
2.18
Home Page Help with ghost image, 2-7
2.19
Transparency Button, 2-7
2.20
Home Page Help with opaque screen, 2-8
2.21
Help Navigation Buttons, 2-8
2.22
About Page, 2-9
3.1
Home Page, 3-2
3.2
Zonal Operation Page with Cancel Button, 3-3
3.3
Set Speed Page, 3-3
3.4
Select Rotor, 3-4
3.5
Set Acceleration/Deceleration Profiles Page, 3-5
3.6
Set Time Page, 3-6
3.7
Delay Start Page, 3-7
3.8
Set Temperature Page, 3-8
3.9
Start Button, 3-9
3.10
Zonal Page, 3-10
3.11
Zonal Page, 3-11
Illustrations
4.1
Run History (Filtered View), 4-9
4.2
Run History Button, 4-10
4.3
Run History Filter, 4-10
4.4
Set From Date and Time, 4-11
4.5
Run Graph Button, 4-12
4.6
Run History Button, 4-12
4.7
Run Graph Options, 4-13
4.8
Run Graph Button, 4-13
4.9
Run History Button, 4-14
4.10
Run History Button, 4-14
4.11
Run History, 4-15
4.12
Run History Button, 4-15
4.13
Before Run Comment, 4-18
4.14
Signature, 4-19
5.1
Program Button, 5-2
5.2
Home, 5-2
5.3
Select Program, 5-3
5.4
Unnamed program, 5-3
5.5
New Program Name, 5-4
5.6
Set Acceleration/Deceleration Profiles, 5-4
5.7
Select Rotor, 5-5
5.8
New Step, 5-5
5.9
New Step in a numbered sequence, 5-6
5.10
Program Button, 5-7
5.11
Program Button, 5-7
5.12
Program Button, 5-8
6.1
Home Page, 6-3
6.2
Home Page (Run in Progress), 6-5
6.3
Set Speed Page (Rotor Selected), 6-6
6.4
Select Rotor Page (Library), 6-7
6.5
Set Time Page, 6-8
6.6
Delay Start Page, 6-9
6.7
Set Speed ω²t Time Page, 6-10
6.8
Set Temperature Page, 6-11
6.9
Set Acceleration/Deceleration Profiles Page, 6-12
6.10
Login Page, 6-13
6.11
Select Program Page, 6-14
6.12
New Program Page, 6-15
xxiii
Illustrations
xxiv
6.13
Edit Program Page, 6-15
6.14
View Program Page, 6-16
6.15
Select Rotor Page (Catalog), 6-17
6.16
New Step Page, 6-18
6.17
Edit Step Page, 6-18
6.18
Program Log Page, 6-19
6.19
Export Page, 6-20
6.20
Authorize Users Page, 6-21
6.21
Import Page, 6-22
6.22
Real-Time Run Data Page, 6-23
6.23
Historical Run Data Page, 6-23
6.24
Run Graph Button, 6-24
6.25
Run Graph Options Page, 6-24
6.26
Run History Page, 6-25
6.27
Run History Page (E-Signature Enabled), 6-26
6.28
Run History Button, 6-26
6.29
Run History Filter Page, 6-27
6.30
Before Run Comment Page, 6-28
6.31
Menu Page, 6-29
6.32
System Options Page, Basic Tab, 6-30
6.33
System Options Page, System Tab, 6-31
6.34
System Options Page, Network Tab, 6-32
6.35
System Options Page, Users Tab, 6-33
6.36
System Options Page, Reports Tab, 6-34
6.37
Select Language Page, 6-35
6.38
User Options Page, 6-36
6.39
Max Temperature Offset Page, 6-37
6.40
Reset User PIN Page, 6-38
6.41
Select Image Page (Avatar), 6-39
6.42
Select Image Page (Background), 6-39
6.43
Set Date and Time Page, 6-40
6.44
System Log Page, 6-41
6.45
Manage Rotors Page, 6-42
6.46
Add to Rotor Library Page, 6-43
6.47
Diagnostic History Page, 6-44
6.48
Set Sound Page, 6-45
6.49
Custom Sounds Page, 6-46
6.50
Archive Data Page, 6-47
Illustrations
6.51
Setup Network Page, 6-48
6.52
Select Printer Page, 6-49
6.53
Setup Email Page, 6-50
6.54
Setup VNC Page, 6-51
6.55
Manage Users Page, 6-52
6.56
Add User Page, 6-53
6.57
Authorize Programs Page, 6-54
6.58
Rotor Catalog Page, 6-55
6.59
About Page, 6-56
6.60
Zonal Authorization Page, 6-57
6.61
Zonal Mode Button, 6-57
6.62
Zonal Operation Page, 6-58
7.1
Front View of Vacuum Pump, 7-5
7.2
Emergency Door Release Latch Access, 7-7
7.3
Manual Door Release, 7-8
7.4
Venting the Chamber Vacuum - Removing the Red Hose, 7-9
7.5
Venting the Chamber Vacuum - Replacing the Red Hose, 7-9
7.6
Front Panel Retaining Strip, 7-10
A.1
Single-Phase Electrical Requirements, A-3
A.2
Three-Phase “Y” Electrical Requirements, A-3
A.3
Correct and Incorrect Three-Phase Power Configurations, A-4
A.4
Checking the Rotor for Drive Pins, A-6
E.1
HEPA Filter Replacement, E-1
xxv
Tables
Tables
xxvi
1.1
Avanti JXN Series Specifications, 1-5
1.2
Available Rotors, 1-7
4.1
User Levels, 4-5
6.1
Acceleration and Deceleration Profiles, 6-13
7.1
Replacement Parts, 7-12
A.1
Nominal Supply Voltage Ratings for the Avanti JXN Series, A-2
A.2
Required Wire Connections, A-3
C.1
Diagnostics/User Messages Chart, C-1
Introduction
Overview
This introduction contains the following information:
• About This Manual
• Conventions
• Certification
• Scope of Manual
• CFC-Free Centrifugation
• Software Copyright
• Symbols
• Graphics
About This Manual
The information in your User’s Manual is organized as follows:
CHAPTER 1, Description
Describes the Avanti JXN series centrifuge components and their functions. It also describes system
safety features and centrifuge controls and displays.
CHAPTER 2, The Touch Screen Interface
Describes the touch screen interface for the Avanti JXN series.
CHAPTER 3, Operations
Describes the Manual Operation and the Zonal and Continuous Flow Operation.
CHAPTER 4, Configuration
Describes configuration options for the system and the effects on system functionality.
CHAPTER 5, Programs
Describes the functionality of creating and storing programs in the centrifuge memory.
CHAPTER 6, Functional Pages
Describes the functional pages used to control the Avanti JXN series.
PN B38322AB
xxvii
Introduction
Conventions
CHAPTER 7, Maintenance and Troubleshooting
Contains care and maintenance procedures to be performed regularly.
Additionally, this manual includes several appendices that cover a range of topics including
Preinstallation, Temperature Calibration, Diagnostics, and Legal Notices.
This manual also includes a list of Abbreviations (including acronyms), and the Beckman Coulter,
Inc. Customer End User License Agreement.
Conventions
This manual applies the following conventions:
• Bold font indicates a screen icon or menu item on the Workstation screen.
• Italics font indicates screen text displayed by the Workstation.
• Blue and underlined text indicates that you can click on the text to access related information.
• The term ‘select’ is used to indicate either one or both of the following actions:
— to tap or touch your finger on the touch screen
— to click with a mouse
IMPORTANT IMPORTANT is used for statements that add value to a particular step or procedure being
performed. Following the advice in the IMPORTANT adds benefit to the performance of a piece of
equipment or to a process.
NOTE NOTE is used to call attention to notable information that should be followed during use or
maintenance of this equipment.
Certification
To ensure full system quality, Beckman Coulter Avanti JXN series have been manufactured in a
facility that maintains certifications to both ISO 9001:2008 and ISO 13485:2003. They have been
designed and tested to conform to (when used with Beckman Coulter rotors) the laboratory
equipment requirements of applicable regulatory agencies. Declarations of conformity and
certificates of compliance are available at www.beckmancoulter.com.
Scope of Manual
This manual is designed to familiarize you with the Avanti JXN series, its functions, specifications,
operation, and routine operator care and maintenance. Read this entire manual, especially the
xxviii
PN B38322AB
Introduction
CFC-Free Centrifugation
safety notices and all safety-related information, before operating the instrument or performing
maintenance.
NOTE If the instrument is used in a manner other than specified in this manual, the safety and performance
of this equipment could be impaired. Further, the use of any equipment other than that recommended
by Beckman Coulter has not been evaluated for safety. Use of any equipment not specifically
recommended in this manual and/or the appropriate rotor manual is the sole responsibility of the user.
CFC-Free Centrifugation
To ensure minimal environmental impact, no CFCs are used in the manufacture or operation of the
Avanti JXN series centrifuge.
Software Copyright
The software and other information incorporated into the Avanti JXN series is protected by
international copyright laws. Unauthorized copying, use, distribution, transfer, or sale is a violation
of those laws that may result in civil or criminal penalties. This computer program is also subject to
additional restrictions contained in the following Microsoft OEM Customer License Agreement for
Embedded Systems:
“If you use the Device to access or utilize the services or functionality of Microsoft Windows XP
Server (all editions), or use the Device to permit workstation or computing devices to access or
utilize the services or functionality of Microsoft Windows XP Server, you may be required to obtain
a Client Access License for the Device and/or each such workstation or computing device. Refer to
the End-User License Agreement for Microsoft Windows XP Server for additional information.”
The End-User License Agreement is available on the Microsoft Embedded Systems website.
PN B38322AB
xxix
Introduction
Symbols
Symbols
xxx
PN B38322AB
Introduction
Graphics
Graphics
All graphics, including screens and printouts, are for illustration purposes only and must not be
used for any other purpose. The graphics that your system generates may differ from what is
displayed in this manual.
PN B38322AB
xxxi
Introduction
Graphics
xxxii
PN B38322AB
CHAPTER 1
Description
Overview
This section describes the Avanti JXN series centrifuge components and their functions. It also
describes system safety features and centrifuge controls and displays. Refer to the applicable rotor
manual for rotor descriptions.
This chapter contains information about:
• For In Vitro Diagnostic Use
• Centrifuge Function
• Touch Screen
• Name Rating Plate
• Housing and Door
• Rotor Chamber
• Friction Reduction System (FRS)
• Drive
• Temperature Sensing and Control
• Overtemp System
• Safety Features
• Specifications
• Available Rotors
For In Vitro Diagnostic Use
This Avanti JXN series centrifuge is intended for use as a general purpose laboratory instrument for
the separation of components through the use of relative centrifugal force. Applications may be
clinical in nature, including the separation of human samples (such as blood, urine, and other bodily
fluids), either alone or after the addition of reagents or other additives; or non-clinical, such as the
separation of non-human bodily samples, chemicals, industrial or environmental samples.
This centrifuge should be operated by qualified professionals only.
PN B38322AB
1-1
Description
Centrifuge Function
Centrifuge Function
The Avanti JXN series is a refrigerated centrifuge that generates centrifugal forces required for a
wide variety of applications. Together with the Beckman Coulter rotors designed for use in this
centrifuge, applications include:
• Routine processing such as sample preparations, pelleting, extractions, purifications,
concentrations, phase separations, and spin column and spin filter centrifugations.
• Rapid sedimentation of protein precipitates, large particles, and cell debris.
• Preparation of subcellular organelles such as mitochondria, nuclei, chloroplasts, and crude
microsomes.
• Separation of blood cells and cellular components.
• Pelleting of prokaryotic and eukaryotic cells.
• Gradient separation, for example, Ficoll-Hypaque and Percoll.
• Nucleic acid precipitation.
• Virus isolation.
• Bacteriophage isolation.
The Avanti JXN series centrifuge design features a brushless switched-reluctance drive motor*, an
automatic rotor identification system, FRS (friction reduction system), vacuum control circuitry,
temperature control system, and programmable acceleration and deceleration times.
Touch Screen
The touch screen is both the information display and the control input for the instrument. As they
are needed, control buttons appear on the screen. When you select a button, you activate that
control.
Each component of the touch screen interface is explained in the following chapters.
Name Rating Plate
A name rating plate is affixed to the rear of the instrument. Always mention the serial number and
model number (available on the About Page) when contacting Beckman Coulter regarding your
instrument.
* Manufactured under license from Switched Reluctance Drives Limited, Harrogate, U.K.
1-2
PN B38322AB
Description
Housing and Door
Housing and Door
The instrument control housing, door assembly, and cover panels are made from a highly-durable
plastic.
The door is opened by stepping on a foot pedal, which is located at the bottom right front of the
instrument. The door is hinged at the back left to open at a 60-degree angle to the centrifuge side
panels, providing clearance for loading and unloading of the centrifuge.
In the event of a power failure, the door can be manually unlocked for sample recovery (see
Accessing the Rotor in Case of Power Failure in CHAPTER 7, Maintenance and Troubleshooting).
Rotor Chamber
The rotor chamber is made of stainless steel to resist corrosion. A rubber gasket around the
chamber opening ensures sealing.
NOTE Instrument gaskets have not been qualified as bioseals for aerosol containment.
Friction Reduction System (FRS)
The friction reduction system (FRS) uses a mechanical rotary vane vacuum pump to reduce
chamber pressure. The pump turns on after the run is started, before rotor friction reaches a high
level. When the required vacuum level is reached, the pump turns off. Vacuum in the chamber is
vented during rotor deceleration.
Drive
The drive spindle is directly driven by a brushless, high-torque, switched-reluctance motor. The
instrument’s resilient suspension minimizes disturbance of the sample during acceleration and
deceleration, and reduces damage to the drive spindle if an imbalance occurs during centrifugation.
Temperature Sensing and Control
The temperature control system is cooled by circulation of a non-CFC-based refrigerant. A
thermistor in the rotor chamber continuously monitors the chamber temperature. The system
calculates the chamber temperature required to maintain the set temperature. Although the
chamber temperature fluctuates during operation, the rotor’s large mass keeps the sample
temperature substantially constant. At the end of a run, the system continues controlling the
temperature to prevent freezing or overheating of the sample.
PN B38322AB
1-3
1
Description
Overtemp System
Overtemp System
An overtemp (over temperature) system provides flexibility, sample protection, and safety for the
user.
• The maximum allowable deviation above the Set Temperature is configured by the user. The
default setting is 4°C.
• For each run the user sets the desired run temperature.
• If the system is configured to shutdown when the set temperature is exceeded, the system shuts
down using maximum brake when the actual temperature exceeds the set temperature by the
overtemp setting.
• To protect the instrument hardware, the system shuts down when the over temperature is
reached. The shutdown cannot be disabled by the user. The system shuts down using maximum
brake when its over temperature shutdown point is exceeded. For a listing of the specified
temperature for each instrument, see Specifications.
Safety Features
Avanti JXN series centrifuges have been designed and tested to operate safely indoors at altitudes
up to 2000 m (6562 ft). Safety features include the following:
• An electromechanical door lock system prevents operator contact with spinning rotors and
prevents run initiation unless the door is closed and locked. The door locks when START is
pressed, or when the POWER switch is turned off. The exception to this is ZONAL mode, in which
open-door operation up to 3000 RPM is allowed.
• A steel casing surrounds the rotor chamber to provide operator protection in the unlikely event
of a rotor mishap.
• Dynamic Rotor Inertia Check (DRIC): As the rotor accelerates, rotor inertia is measured and the
rotor energy is calculated for the speed set by the user. If the calculated rotor energy is
determined to be excessive, the instrument will stop the run and issue a diagnostic message.
• An imbalance detector monitors the system during operation, causing automatic shutdown if
rotor loads are severely out of balance.
1-4
PN B38322AB
Description
Specifications
Specifications
Only values with tolerances or limits are guaranteed data. Values without tolerances are informative data,
without guarantee.
Table 1.1 Avanti JXN Series Specifications
Specifications
Speed
Description
Setting range
Avanti JXN-26
Avanti JXN-30
500 to 26,000 RPM (in 10
RPM increments) or
equivalent RCF (in 10 x g
increments)
500 to 30,000 RPM (in 10
RPM increments) or
equivalent to RCF (in 10 x g
increments)
Speed control (1,000 to
10,000 RPM)
Speed control (10,001 to
max speed)
Time
±0.1%
±0.15%
Setting range
1 min to 99 hr 59 min, ω2t, or continuous (hold)
Actual display
Indicates time remaining (timed run) , ω2t, or elapsed
time (hold run)
ω2t setting range
ω2t actual display
Temperature
±10 RPM
Setting range
Accuracy
Up to 2.6682 x 1012
radians squared per
second
Indicates accumulated centrifugal effect to five
significant digits (in exponential notation)
-10 to +40°C (in 1°C
increments)
Accel/Decel
Dimensions
16 to 38°Cb
50°C
55°C
Cooling fluid
Refrigerant 404A (HVC)
Acceleration
Maximum, timed (1 to 10 min from 0 to 500 RPM)
Deceleration
Maximum, timed (1 to 10 min from 500 to 0 RPM), or
coast
Width
71 cm (28 in.)
Depth
86 cm (34 in.)
Height (with door closed)
86 cm (34 in.)
Height (to top of control
head)
120 cm (47.3 in.)
Height (to top of open door)
Weight
PN B38322AB
-20 to +40°C (in 1°C
increments)
±2°C of chamber temperature (after equilibration)a
Ambient temperature range
Over temperature shutdown
pointc
Up to 3.5524 x 1012
radians squared per
second
149 cm (58.5 in.)
141 cm (55.5 in.)
290 kg (640 lb)
310 kg (680 lb)
1-5
1
Description
Specifications
Table 1.1 Avanti JXN Series Specifications
Specifications
Description
Avanti JXN-26
Avanti JXN-30
Ventilation
Clearances
Sides
7.6 cm (3 in.)
Rear
16 cm (6.25 in.)
Finishes
Top surfaces
Electrical
Uncoated plastic
Painted plastic
Front surfaces
Painted plastic
Other surfaces
Acrylic baking enamal on metal surfaces
Power requirement
200/208/240V, single phase instrument: 180-264 VAC,
30 A, 50/60 Hz
230V, single phase instrument: 180-264 VAC, 30 A,
50 Hz
220/380V plus neutral 3-phased instrument: 313-457
VAC plus neutral, 16A, 50 Hz
Electrical supply
Installation (overvoltage
category)
Environmental
Noise output (1 m in front of
instrument, 1.5 m above the
floor)
Maximum heat dissipation
under steady-state
conditions
Humidity restrictions
Pollution degree
HEPA filter
Class 1
II
62 dBa
5120 Btu/h (1.5 kW)
<80% (noncondensing)
2e
Available
a. Proprietary algorithm applied to provide an estimated sample temperature.
b. To reach temperatures above ambient, the centrifuge is dependent on the frictional heat generated inside the chamber
during operation. At low run speeds or low ambient temperatures, the centrifuge may not be able to achieve some higher
temperatures.
c. If the system reaches this temperature, it will issue a diagnostic and shut down using maximum brake.
d. Unbalanced three-phase. Split for single-phase operation internally.
e. Normally, only nonconductive pollution occurs. Occasionally, however, a temporary conductivity caused by condensation
must be expected.
1-6
PN B38322AB
Description
Available Rotors
Audible Sounds
The Avanti JXN series instrument makes an audible sound for the following events:
• Boot up
• Start of Run
• End of Run
• Diagnostics/Alert
• Door open during Zonal mode
• Key Click
Sound volume can be regulated through the Set Sound Page, and some sounds can be customized
through the System Options. See Custom Sounds Page.
The Door Open during Zonal mode sound cannot be changed or muted. It will play every 5 seconds
when the door could be open.
Available Rotors
Refer to the applicable rotor manual for complete rotor descriptions.
Table 1.2 Available Rotorsa
Rotor Profile
PN B38322AB
Description
JXN-26
Max
RPMb
JXN-30 JXN-26
Max
Max
RPMb RCF
(´ g)
JXN-30
Max
RCF
(´ g)
Max
Capacity
Rotor
Manual
Number
JA-30.50 Ti
Fixed Angle, 34°
(8 place)
rmax = 108 mm
26,000
30,000
81,770
108,860
8 ´ 50 mL
J-TB-070
JA-25.50 Ti
Fixed Angle, 34°
(8 place)
rmax = 108 mm
25,000
25,000
75,600
75,600
8 ´ 50 mL
J-TB-056
JA-25.15 Ti
Fixed Angle, 25°
(24 place)
rmax = 106 mm
(outer row)
rmax = 86 mm
(inner row)
25,000
25,000
24 ´ 15 mL
J-TB-057
74,200
74,200
60,200
60,200
1-7
1
Description
Available Rotors
Table 1.2 Available Rotorsa (Continued)
Rotor Profile
Description
JXN-26
Max
RPMb
JXN-30 JXN-26
Max
Max
RPMb RCF
(´ g)
JXN-30
Max
RCF
(´ g)
Max
Capacity
Rotor
Manual
Number
JA-21
Fixed Angle, 40°
(18 place)
rmax = 102 mm
21,000
21,000
50,380
18 ´ 10 mL
J-TB-002
JA-20.1
Fixed Angle, 23°
(32 Place)
rmax = 115 mm
(outer row)
rmax = 98 mm
(inner row)
20,000
20,000
32 ´ 15 mL
J-TB-022
JA-20
Fixed Angle, 34°
(8 place)
rmax = 108 mm
20,000
8 ´ 50 mL
J-TB-003
JA-18.1
Fixed Angle
(24 place)
45° adapter
rmax = 116 mm
25° adapter
rmax = 112 mm
1-8
20,000
50,380
51,520
51,520
43,900
43,900
48,380
48,380
J-TB-037
18,000
18,000
42,090
42,090
24 ´ 1.8 mL
17,000
17,000
36,250
36,250
24 ´ 1.8 mL
JA-18
Fixed Angle, 23°
(10 place)
rmax = 132 mm
18,000
18,000
47,900
47,900
10 ´ 100
mL
J-TB-035
JA-17
Fixed Angle, 25°
(14 place)
rmax = 132 mm
17,000
17,000
39,810
39,810
14 ´ 50 mL
J-TB-017
JLA-16.250
Fixed Angle, 25°
(6 place)
rmax = 134 mm
16,000
16,000
38,420
38,420
6 ´ 250 mL
J-TB-072
PN B38322AB
Description
Available Rotors
Table 1.2 Available Rotorsa (Continued)
Rotor Profile
PN B38322AB
Description
JXN-26
Max
RPMb
JXN-30 JXN-26
Max
Max
RPMb RCF
(´ g)
JXN-30
Max
RCF
(´ g)
Max
Capacity
Rotor
Manual
Number
JA-14.50
Fixed Angle, 35°
(16 place)
rmax = 160 mm
14,000
14,000
35,050
35,050
16 x 50 mL
B32164
JA-14
Fixed Angle, 25°
(6 place)
rmax = 137 mm
14,000
14,000
30,070
30,070
6 ´ 250 mL
J-TB-004
JA-12
Fixed Angle, 35°
(12 place)
rmax = 144 mm
12,000
12,000
23,220
23,220
12 ´ 50 mL
J-TB-051
JA-10
Fixed Angle, 25°
(6 place)
rmax = 158 mm
10,000
10,000
17,700
17,700
6 ´ 500 mL
J-TB-006
JLA-10.500
Fixed Angle, 20°
(6 place)
rmax = 166 mm
10,000
6 ´ 500 mL
J-TB-048
F10BCI-6x500y
Fixed Angle, 23°
(6 place)
rmax = 158 mm
10,000
10,000
17,700
17,700
6 ´ 500 mL
—
JLA-9.1000
Fixed Angle, 20°
(4 place)
rmax = 185 mm
9,000
9,000
16,780
16,780
4 ´ 1000
mL
J-TB-073
JLA-8.1000
Fixed Angle, 20°
(6 place)
rmax = 222.8 mm
8,000
—
15,970
—
6 ´ 1000
mL
J-TB-073
JS-13.1
Swinging Bucket
(6 place)
rmax = 140 mm
13,000
13,000
26,500
26,500
6 ´ 50 mL
J-TB-036
18,590
1-9
1
Description
Available Rotors
Table 1.2 Available Rotorsa (Continued)
Rotor Profile
Description
JXN-26
Max
RPMb
JXN-30 JXN-26
Max
Max
RPMb RCF
(´ g)
JXN-30
Max
RCF
(´ g)
Max
Capacity
Rotor
Manual
Number
JS-24.38
Swinging Bucket
(6 place)
rmax = 161 mm
10,000
24,000
18,030
103,860 6 ´ 38.5 mL J-TB-058
JS-24.15
Swinging Bucket
(6 place)
rmax = 171.3 mm
10,000
24,000
19,190
110,510
6 ´ 15 mL
J-TB-058
JS-7.5
Swinging Bucket
(4 place)
rmax = 165 mm
Four bucket types:
7,500
7,500
10,400
10,400
4 ´ 250 mL
J-TB-007
JS-5.3
Swinging Bucket
(4 place)
rmax = 194.8 mm
5,300
—
6,870
—
24
J-TB-089
microplates
8 deep-well
plates
4 squarewell plates
JS-4.3
Swinging Bucket
(4 place)
rmax = 204 mm
4,300
—
4,220
—
4 ´ 750 mL
J-TB-050
JS-4.0
Swinging Bucket
(4 place)
rmax = 226 mm
4,000
—
4,050
—
4 ´ 1 liter
4 blood
bags
12
microplates
148 RIA
tubes
J-6TB006
• 4x250 mL
• 12x50 mL
(4x3x50)
• 16x50 mL
(4x4x50)
• 24x5 mL
(6x6x5)
1-10
PN B38322AB
Description
Available Rotors
Table 1.2 Available Rotorsa (Continued)
Rotor Profile
Description
JCF-Z
Continuous Flow/
Zonal Rotor
JXN-26
Max
RPMb
20,000
JXN-30 JXN-26
Max
Max
RPMb RCF
(´ g)
JXN-30
Max
RCF
(´ g)
Max
Capacity
39,870
39,870
660 mL
(standard
core)
39,870
39,870
1250 mL
(large core)
36,290
36,290
240 mL
(small core)
20,000
39,870
39,870
1750 mL
(reorienting
gradient)
39,870
39,870
1900 mL
(standard
zonal)
Rotor
Manual
Number
JCFZ-IM
a. When operating at the maximum speed for the rotor, the minimum temperature cannot be selected for all rotors. Refer to
the specific rotor IFU for details.
b. Maximum speeds are based on a solution density of 1.2 g/mL with the following exceptions: the JA-18.1 rotor is rated for a
density of 1.4 g/mL; the JCF-Z rotor is rated for a density of 1.45 g/mL
PN B38322AB
1-11
1
Description
Available Rotors
1-12
PN B38322AB
CHAPTER 2
The Touch Screen Interface
Overview
This chapter describes the touch screen interface for the Avanti JXN series. Except for the power
switch, all the controls for the instrument are programmed controls that appear on the touch
screen.
Figure 2.1 Home Page
This chapter contains information about:
• Areas on the Screen
• Help Messages
• About Your Instrument
PN B38322AB
2-1
The Touch Screen Interface
Areas on the Screen
Areas on the Screen
The items on the screen may change, depending on the state of the instrument. There are three
areas where items appear on the screen:
• The Header Bar
• The Footer Bar
• The Page Display Area
Header Bar
Figure 2.2 Header Bar
The area across the top of the screen is called the Header Bar, containing four important items:
• Home Page Button
• Menu Button
• Status Display
• Help Button
The following sections explain these items.
Home Page Button
Figure 2.3 Home Page Button
The Home Page Button displays the Home Page from any other page. When you use Zonal Mode, the
Zonal Operation Page replaces the Home Page.
2-2
PN B38322AB
The Touch Screen Interface
Areas on the Screen
Menu Button
Figure 2.4 Menu Button
The Menu Button displays the Menu page, including the following functions:
• Options
• Rotor Catalog
• About
• Zonal Operation
• Service Mode
The menu options are explained in the following chapters.
Status Display
Figure 2.5 Ready Status
The Status Display is in the middle of the Header Bar and shows you the current instrument status,
the current program (if selected) and program step (if running). The Status Display also shows when
a delayed run is scheduled or pending, a remote user is logged in, or service mode is enabled. The
background color of the header bar changes with the type of status:
• Blue background: system ready (no run in progress).
Figure 2.6 Header Bar - Ready Status
• Green background: in operation (run in progress).
Figure 2.7 Header Bar - Running Status
• Green background: in operation (stop in progress).
PN B38322AB
2-3
2
The Touch Screen Interface
Areas on the Screen
Figure 2.8 Header Bar - Stopping Status
• Yellow background: warning message.
Figure 2.9 Header Bar - Warning Message
• Red background: error message.
Figure 2.10 Header Bar - Error Message
Help Button
Figure 2.11 Help Button
The Help button gives you access to the built-in online help messages. Help messages are described
at the end of this chapter in Help Messages.
Footer Bar
The bottom of the touch screen always shows the footer bar. The footer bar appears in two different
ways, but it always has the Start Button at the left and the Stop Button at the right.
Start Button
Figure 2.12 Start Button
The Start Button begins a run with the current settings. Use it only after you have set the
parameters for the run.
2-4
PN B38322AB
The Touch Screen Interface
Areas on the Screen
Stop Button
Figure 2.13 Stop Button
The Stop button stops the current run immediately. This is ordinarily only used for emergencies or
if you mistakenly set too long a run time.
Footer Bar on the Home Page
On the Home Page, the middle of the Footer Bar shows three Items:
• The Rotor Display/Button
• The System Name
• The Accel and Decel Display/Button
Figure 2.14 Footer Bar - Home Page
Each of these is explained below.
Footer Bar on Other Pages
When not on the Home Page, the three buttons for Speed, Time and Temperature appear in the
Footer Bar for easy access. To set Acceleration or Deceleration profiles, select the Home button to
return to the Home Page. The following items are described in detail within the Home Page section
of the next chapter:
• The Set Speed Display/Button
• The Set Time Display/Button
• The Set Temp Display/Button
Figure 2.15 Footer Bar on Other Pages
Rotor Display/Button
As a display, the Rotor Display/Button shows the current selected rotor. Select the button to display
the Select Rotor page, described in CHAPTER 6, Functional Pages.
PN B38322AB
2-5
2
The Touch Screen Interface
Help Messages
System Name
The system name displays the system name entered as one of the options on the System Options
Page. This section also displays the user currently logged in to the system (if enabled), and the
avatar and background (if selected) for that user.
Accel and Decel Display/Button
These are two displays that, together, act as a single button.
As a display, each shows the currently selected acceleration or deceleration profile. Select the
button to display the Set Acceleration/Deceleration Profiles Page, described in CHAPTER 6.
Page Display Area
The Page Display Area is the main display area between the Header Bar and the Footer Bar. The
pages and help messages all appear in this area. The pages are all described in CHAPTER 6.
Help Messages
When you first select the Help Button, a number of new buttons appear on the screen, giving you
three options:
• Item Help
• Global Help
• Exit from Help
Item Help
Item Help Buttons appear next to individual fields or objects. Select the button to display a brief
message describing the item. Only one help message remains on the screen at a time.
Figure 2.16 Item Help Button
Global Help
The Global Help Button appears next to the Help Button. If you select the Global Help Button, the
Page Display Area shows you a description of the current page and all the elements it contains.
2-6
PN B38322AB
The Touch Screen Interface
Help Messages
Figure 2.17 Global Help Button attached to Help Button
While using Global Help, you also have some additional options:
• The Global Help page appears over a ghost image of the screen you were on when you selected
global help.
Figure 2.18 Home Page Help with ghost image
If the ghost image makes it difficult for you to read the Help Page, select the Transparency
Button in the upper right corner.
Figure 2.19 Transparency Button
The resulting opaque help page eliminates the image of the screen behind it.
PN B38322AB
2-7
2
The Touch Screen Interface
About Your Instrument
Figure 2.20 Home Page Help with opaque screen
Select the Transparency Button again to return to the ghost screen image.
• If you need information about some other aspect of the instrument, you can select the Table of
Contents link at the bottom of the page to see the outline of all the available help pages. You
have access to all of the help pages from the Table of Contents.
Figure 2.21 Help Navigation Buttons
• To navigate through your selected help pages, use the Forward and Back buttons in the upper
left corner.
Exit from Help
Select the Help button to exit help mode and return to the previous screen.
About Your Instrument
The system About page contains information about your instrument, including the model number,
serial number, and software version, that you need when you call your Beckman Coulter
Representative. Follow this procedure to display the About Page.
2-8
PN B38322AB
The Touch Screen Interface
About Your Instrument
Figure 2.22 About Page
Displaying the About Page
PN B38322AB
1
Select the Menu button on the header bar to display the Menu page.
2
Select the About button to display the About page.
2-9
2
The Touch Screen Interface
About Your Instrument
2-10
PN B38322AB
CHAPTER 3
Operations
Overview
The touch screen interface for the Avanti JXN simplifies operations. Although there are many
additional things you can do.
This chapter contains information about:
• Manual Operation
• Zonal and Continuous Flow Operation
Manual Operation
Manual operation is a simple procedure you can do from the Home Page.
Before you begin, you must know:
• Which rotor you are using for the run
• Acceleration and deceleration rate
• Run speed
• Length of time for the run
• Run temperature
NOTE Your system may have additional requirements, depending on your configuration.
When you have this information, the procedure for the run is as follows:
Operating the Run Manually
PN B38322AB
1
Start on the Home Page.
2
Set the speed and rotor.
3
Set the Acceleration and Deceleration profiles.
3-1
Operations
Manual Operation
4
Set the time.
5
Set the temperature.
6
Start the run.
Step 1: Start on the Home Page
Start at the Home Page. If your screen shows any other page, select the Home Page Button in the
upper left corner of the screen.
Figure 3.1 Home Page
NOTE If your system is in Zonal Mode, you must select the Cancel Button to go to the Home Page.
3-2
PN B38322AB
Operations
Manual Operation
Figure 3.2 Zonal Operation Page with Cancel Button
Step 2: Set the Speed and Rotor
Select the Set Speed Display/Button on the Home Page to go to the Set Speed Page.
Figure 3.3 Set Speed Page
When the Set Speed Page appears, follow these steps:
PN B38322AB
3-3
3
Operations
Manual Operation
Setting the Speed and Rotor
1
Select the Select Rotor Button to go to the Select Rotor Page.
Figure 3.4 Select Rotor
2
3
4
5
6
Select the rotor for the run from the library. If the desired rotor is not in the library, a system
Administrator or Super User must add it.
Select the OK Button to return to the Set Speed Page.
If you plan to set the speed in units of relative centrifugal field (RCF), select the RPM/RCF Button.
Note that the RPM/RCF button is only enabled when you have selected a rotor.
Use the keypad to set the desired speed. Note that the speed is set in 10-rpm (or x g when
entering RCF) increments, with a zero added to your number. You can also use the Back and
Clear keys to make corrections.
Select the OK key to accept your entry and dismiss the page.
Step 3: Set the Acceleration and Deceleration Profiles
Select the Accel and Decel Display/Button to go to the Set Acceleration/Deceleration Profiles Page.
3-4
PN B38322AB
Operations
Manual Operation
Figure 3.5 Set Acceleration/Deceleration Profiles Page
On the Set Acceleration/Deceleration Profiles Page, follow these steps:
Setting the Acceleration and Deceleration Profiles
PN B38322AB
1
Select the desired Acceleration and Deceleration profiles.
2
Select the OK key to accept your entries and dismiss the page.
3-5
3
Operations
Manual Operation
Step 4: Set the Time
Select the Set Time Display/Button to go to the Set Time Page.
Figure 3.6 Set Time Page
On the Set Time Page, follow these steps:
Setting the Time
1
3-6
Use the keypad to set the desired time in hours and minutes. Use the Back and Clear keys to
make corrections. You can also use the Hold key to set the time to a hold state with no
countdown to an automatic end. When you select Hold, the run does not end until you select
the Stop key (or until the maximum time of 99 hours and 59 minutes has been reached).
PN B38322AB
Operations
Manual Operation
2
You can use the Delay Start button to set a future start or stop time. Select Delay Start to display
the Delay Start Page.
Figure 3.7 Delay Start Page
• Select Start At or Stop At to set a starting or stopping time. Then you can set the date and
time in the fields above. Select OK to return to the Set Time Page.
3
PN B38322AB
Select the OK key to accept your entry and dismiss the page.
3-7
3
Operations
Manual Operation
Step 5: Set the Temperature
Select the Set Temp Display/Button to go to the Set Temperature Page.
Figure 3.8 Set Temperature Page
On the Set Temperature Page, follow two steps:
Setting the Temperature
1
2
Use the keypad to set the desired temperature in degrees Celsius. Use the Back and Clear keys
to make corrections.
Select the OK key to accept your entry and dismiss the page.
Step 6: Start the Run
Once the run values are set, start the run:
NOTE If you have entered a delayed start, you must select the Start button to begin the countdown to the
delayed start.
1
2
3-8
Prepare your samples and place them in the rotor following all proper procedures, including
balanced weight distribution.
Preheat or precool the rotor and samples, if necessary.
PN B38322AB
Operations
Zonal and Continuous Flow Operation
3
Mount the rotor in the instrument following all the procedures in the rotor manual and
observing all safety procedures and cautions.
4
Close the chamber door.
5
Select the Start button.
Figure 3.9 Start Button
NOTE When the run begins, wait for the countdown timer to reach zero and the rotor to come to a stop.
You can then remove your rotor and samples.
Zonal and Continuous Flow Operation
WARNING
Risk of operator injury. In zonal and continuous flow operation, the operator is
unavoidably exposed to rotating machinery. For safety, the operator must be
properly instructed and qualified. Guard against accidentally dropping objects,
such as pens, pencils, or hemostats into the chamber. Loose lab coats, neckties,
scarves, and long necklaces should not be worn while operating in the zonal or
continuous flow mode.
Use only zonal/continuous flow rotors in the Zonal mode.
Zonal and Continuous Flow operations require special rotors and have some additional hazards in
that samples are loaded and unloaded while the rotor is spinning. To prevent unauthorized users
from attempting these operations, the instrument requires an authorization code (which is 1793).
When Zonal operations are authorized, the system displays the Zonal Operation Page. While in Zonal
operation, the Home Page button displays the Zonal Operation page. The mode does not end until
the run is complete or the user selects the Cancel Button to end the mode.
PN B38322AB
3-9
3
Operations
Zonal and Continuous Flow Operation
Zonal and Continuous Flow operations are very similar. The specific details vary according to the
rotor you are using, but the summary below shows an outline of the procedure.
Figure 3.10 Zonal Page
There are seven phases to a Zonal or Continuous Flow run:
• Preparing
• Starting
• Loading
• Running
• Unloading
• Stopping
• Finishing
Each phase is outlined in a section below.
Preparing for the Run
The rotor manual details the preparations for a run, which may include cleaning, assembling, and
lubricating the rotor, setting up pumps and tubing, and usually includes overnight cooling to
precondition the rotor, sample and solutions used in the run. When you are ready to install the
rotor, set the parameters for the run:
• Run Speed
• Run Time
• Temperature
• Load Speed
• Unload Speed
3-10
PN B38322AB
Operations
Zonal and Continuous Flow Operation
For Continuous Flow operation, you may have two different load speed settings. The initial setting
is for alignment and adjustment checks, which you set in this phase.
When everything else is ready, mount the rotor.
Starting the Run
To start the run, select the Start Button and wait for the rotor to reach loading speed. The status
display at the top of the screen highlights Starting.
For a Continuous Flow run, you need to perform alignment and adjustment checks as detailed in the
rotor manual. You may need to use the Slow to Zero RPM button to make adjustments and restart
with the Start Button. Using the Slow to Zero RPM button will bring the rotor to a stop, but the
instrument will remain in Zonal mode. Refer to Figure 3.11. When the rotor passes the alignment
and adjustment checks, set the new loading speed (if it is different from the adjustment speed) and
select the Start Button again.
Figure 3.11 Zonal Page
When the rotor reaches the Loading speed, the status display highlights Loading, to show that you
have moved into the next phase.
Loading the Sample
In the Loading phase, you inject the sample into the medium in the rotor. Again, the details depend
on the rotor and the type of operation as detailed in the rotor manual. When you have finished all
the specified loading steps, close the door and select the To Running button to go to the next phase.
NOTE While operating in Zonal mode, open-door operation up to 3000 RPM is allowed, but only during the
Loading and Unloading steps.
PN B38322AB
3-11
3
Operations
Zonal and Continuous Flow Operation
Running the Sample
The instrument highlights Running on the Status Display, accelerates to the set run speed, and
begins counting down the set run time. The run phase ends in one of three ways:
• When the timer countdown reaches zero, the instrument decelerates to the unloading speed
and goes to the Unloading phase.
• If you select the To Unloading Button to terminate the run early, the instrument decelerates to
the unloading speed and goes to the Unloading phase.
• If you select the Stop Button to abort the run, the instrument brings the rotor to a halt, skips
the unloading phase, and exits Zonal mode entirely.
If you need to return to the Loading phase to open the door while the rotor is spinning, press the To
Loading button and the instrument will slow the rotor to the Load Speed. The instrument will
remain in the Loading phase until you select the To Running button to return to the Running phase
or terminate the run.
Unloading the Sample
While the rotor is running at unload speed, follow the instructions in the rotor manual to inject the
displacement solution into the rotor and collect the resulting centrifugate sample.
If you need to return to the Running phase for any reason, press the To Running button and the
instrument will accelerate the rotor to the Run Speed. The instrument will remain in the Running
phase until it is ended in one of the ways discussed in Running the Sample.
Stopping the Run
When you have completed all the defined unloading steps, select the Stop Button to bring the rotor
to a halt.
Finishing the Run
When the rotor comes to a halt, unmount it and perform all the cleanup and follow-up steps given
in the rotor manual. The instrument exits Zonal mode when the rotor comes to a stop.
3-12
PN B38322AB
CHAPTER 4
Configuration
Overview
The Avanti JXN series includes many options for configuring your system. Some of these options
have a significant effect on system functionality, and must be configured before you begin to use
the system.
This chapter contains information about:
• Managing Your Network
• Managing Users
• Managing Rotors
• Managing Reports
Managing Your Network
You can add the Avanti JXN series to your network, enabling email, file transfer, and printing to a
network printer. You can also enable VNC (Virtual Network Computing) or API (Application
Programming Interface) to allow the system to receive instructions from a remote application.
Setting Up the Network
1
Select the Menu button on the Header Bar to display the Menu page.
2
Select Options to display the System Options page.
3
Select the Network Tab, then select Setup Network to display the Setup Network page.
4
Network path is the path the instrument automatically uses for import and export. Select the
Network Path field to display the Network Path page and enter the default path. Select OK to
return to the Setup Network page.
PN B38322AB
4-1
Configuration
Managing Your Network
5
DHCP Mode (Dynamic Host Configuration Protocol) is enabled by default and automatically
configures the IP addressing parameters using a DHCP Server on the network.
If your network administrator provides a specific IP address, disable DHCP mode and enter the
values provided for the following fields:
• IP Address
• Subnet Mask
• Default Gateway
• DNS Server
To disable DHCP Mode, select Enable so that the green square is cleared.
6
Select Save to save the network information and return to the System Options page.
Selecting a Printer
Use this option to select a USB or network printer for the instrument. The system automatically
sends all print requests to the selected printer.
NOTE Printer drivers must be installed by your Beckman Coulter Representative.
1
Select the Menu Button on the Header Bar to display the Menu page.
2
Select Options to display the System Options page.
3
Select the Network Tab, then select Select Printer to display the Select Printer page, which lists
the available printers.
4
Select a printer from the list. You can select Test Print to send a test page to the printer.
5
Select Save to save the printer selection and return to the System Options page.
Setting Up Email
Use this option to configure email that can be sent from the instrument. The instrument will send
diagnostic notifications to the email account of all users with an email address entered in their user
profile.
4-2
PN B38322AB
Configuration
Managing Your Network
1
Select the Menu button on the Header Bar to display the Menu page.
2
Select Options to display the System Options page.
3
Select the Network Tab, then select Setup Email to display the Setup Email page.
4
5
6
7
Select SMTP Server to enter your email server address. Select OK to save the address and return
to the Setup Email page.
Port Number defaults to 25. Do not change it unless you must use another, specific port number.
User Name and Password are optional, but may be required by your email server. Select the
fields to enter the required values, then select OK to return to the Setup Email page.
Email From defines the return email address that appears on email notifications sent by the
instrument. You can change the default to a legitimate or fictitious address, depending on your
requirements. Select the field to enter the new address, then select OK to save the address and
return to the Setup Email page.
8
9
Select the SSL Server Enable button to enable email encryption, if required by your email
server. The button displays a green square when the option is enabled.
You can select Test Email to send an email to test your configuration. Enter the recipient email
address and select OK to send the email and return to the Setup Email page. The system displays
a status message for the success or failure sending the test email.
10 When you have completed your configuration, select Save to return to the System Options page.
Setting Up VNC
Use VNC (Virtual Network Computing) to connect to the instrument from a laptop or other remote
device.
1
PN B38322AB
Select the Menu Button on the Header Bar to display the Menu page.
4-3
4
Configuration
Managing Users
2
Select Options to display the System Options page.
3
Select the Network Tab, then select Setup VNC to display the Setup VNC page.
4
5
6
Select the Enable or Disable VNC Server Enable button to enable the VNC server. The button
displays a green square when the option is enabled.
To use the PIN of the current user as the VNC password, select the Synchronize VNC Password
To Logged in User PIN Enable button. To enter a separate VNC password, select Set Password.
Enter and confirm the password and select OK to save and return to the Setup VNC page.
Select Back to return to the System Options page.
Enabling API
Use this option to allow a remote device to connect to the instrument using the API.
1
Select the Menu Button on the Header Bar to display the Menu page.
2
Select Options to display the System Options page.
3
Select the Network Tab, then select Enable API. The button displays a green square when the
option is enabled.
NOTE This button is only active when Require Login is enabled and you are logged into the system as
an Administrator.
4
Select Done to return to the Home page.
Managing Users
You can require users to log in prior to using the Avanti JXN series. You can use the login to build a
run log for each user, and to control access to the system.
The system includes three user levels that grant different ranges of system access.
4-4
PN B38322AB
Configuration
Managing Users
Table 4.1 User Levels
User Level
Permission
Operator
Can run assigned programs and change user options.
Super User
Can run all programs, run the centrifuge manually, manage users,
assign programs, and manage the rotor library.
Administrator
Unlimited access.
Adding Users
1
To add users to the system, select the Menu Button on the Header Bar to display the Menu Page.
2
Select Options to display the System Options Page.
3
Select the Users Tab, then select Manage Users to display the Manage Users page.
4
Select Add to display the Add User Page.
5
Select the User ID field to display the Edit User ID Page.
6
Use the keypad to enter the new User ID. Select OK to return to the Add User page.
7
Repeat the procedure for the remaining fields. The PIN and Full Name fields are required.
8
9
Select the User Level. For Operators, you can select the Authorize Programs button to add
programs to the User. See Creating Programs in CHAPTER 5, Programs for more information.
Select Save to add the user to the system and return to the Manage Users Page.
You can also use the Manage Users page to edit or delete users, to copy existing user information
for a new user, or to edit program permissions for Operator-level users.
Requiring Login
1
PN B38322AB
Select the Menu Button on the Header Bar to display the Menu Page.
4-5
4
Configuration
Managing Users
2
3
Select Options to display the System Options Page.
Select the Users Tab, then select Require Login. The button displays a green square when the
option is enabled.
PIN Expiration and Logout Timer
The system defaults to expire PINs every 60 days, and to log out users after two minutes of
inactivity. Follow these steps to change the defaults.
Changing the Defaults for the PIN Expiration and Logout Timer
1
Select the Menu Button on the Header Bar to display the Menu Page.
2
Select Options to display the System Options Page.
3
Select the Users Tab.
4
To change the PIN expiration, select the PIN Expiration button.
5
6
Select OK to return to the Users Tab.
7
To change the logout time, select the Logout Timer button.
8
9
4-6
Select Clear to clear the field. Enter the number of days that you want PINs to remain valid. To
disable PIN Expiration, enter 0.
Change the field to the number of minutes of inactivity before the system logs out a user. To
disable the Logout Timer, enter 0.
Select OK to return to the Users Tab.
PN B38322AB
Configuration
Managing Rotors
User Options
When Login is required, the User Options page becomes active. From this page, users can change
their PIN, add or change their email and phone number, and select an avatar and background to
appear on their Home page.
Changing User Options
1
Select the Menu button on the Header Bar to display the Menu page.
2
Select Options to display the System Options page.
3
4
Select the Basic Tab, then select User Options. The system displays the User Options page for the
user that is currently logged in.
To change the PIN, select the PIN field to display the Reset User PIN page.
• Use the keypad to enter the current PIN, and confirm the new PIN.
• Select Save to change the PIN and return to the User Options Page.
5
To add or change the email or phone number, select the Email or Phone field to display the Edit
Email or Edit Phone page.
• Use the keypad to update the field.
• Select Save to save your changes and return to the User Options Page.
6
To select or change the avatar or background, select Set Avatar or Set Background to display the
Select Image Page.
• Select an image from the available images on the left, or select Import Image to import an
image from a USB device or network location.
• Select Save to set the image and return to the User Options Page.
7
Select Done to return to the System Options page.
Managing Rotors
When you enter a manual run, you must record the rotor that you are using. Once a rotor is selected,
you can track rotor usage and convert from RPM to RCF.
To make rotors available for selection, you must add rotors to the rotor library.
PN B38322AB
4-7
4
Configuration
Managing Rotors
Adding Rotors
1
To add rotors to the rotor library, select the Menu button on the Header Bar to display the Menu
page.
2
Select Options to display the System Options page.
3
Select the System Tab, then select Manage Rotors to display the Manage Rotors page.
4
Select Add to display the Add to Rotor Library page.
5
Select a type of rotor from the list on the left.
6
7
8
You must enter a serial number for the rotor. Select the Serial Number field to display the Serial
Number Page. Enter the serial number and select OK to return to the Add to Rotor Library page.
If you want to enter an existing run count, repeat the procedure for the Run Count field. The run
count will increment automatically as the rotor is used.
Select Save to add the rotor to the Rotor Library and return to the Manage Rotors Page.
NOTE You can also use the Manage Rotors page to delete rotors from the library.
4-8
PN B38322AB
Configuration
Managing Reports
Managing Reports
The Avanti JXN series automatically saves run history data associated with each run. The run
history generated includes:
Figure 4.1 Run History (Filtered View)
• User information
• Start date and time of the run
• End date and time of the run
• Rotor type
• Program name
• Acceleration and Deceleration parameters
• Before Run Comment
• After Run Comment
• Detailed information about each step in a run
• Graph of the run
• Electronic signature (if applicable)
User Access
• An Operator-level user can manually filter data, graph data, and print data for a run.
• A Super User-level user can also export run history data to an external media source, such as a
USB drive or network location.
• An Administrator-level user can also configure the Avanti JXN series to automatically print
and/or export run history data.
PN B38322AB
4-9
4
Configuration
Managing Reports
Filtering Data
You can filter run history data before you graph or print it.
1
On the Home page, select the Run History button on the side menu.
Figure 4.2 Run History Button
2
3
On the Run History page, select the Filter tab at the bottom of the screen.
On the Run History Filter page, select the Filter by User button and choose from the options
below.
Figure 4.3 Run History Filter
4-10
PN B38322AB
Configuration
Managing Reports
4
Select the Filter by Date button, then select the From button.
Figure 4.4 Set From Date and Time
5
6
7
8
On the Set From Date and Time page, use the up and down arrow buttons to set the parameters
for the Month, Day, Year, Hour, Minute, and AM/PM. Then select OK to return to the Run History
Filter page.
Select the To button under Filter by Date.
On the Set To Date and Time page, again use the up and down arrow buttons to set the
parameters for Month, Day, Year, Hour, Minute, and AM/PM (depending on selected time
format). Then select OK to return to the Run History Filter page.
On the Run History Filter page, select OK to return to the Run History page.
You can now Print, Graph or Export the filtered run history.
PN B38322AB
4-11
4
Configuration
Managing Reports
Graphing Data
To graph data for a run in progress:
Graphing Data for a Run in Progress
1
Select the Run Graph button on the side menu of the Home page.
Figure 4.5 Run Graph Button
2
3
On the Real-Time Run Data page, select Options.
On the Run Graph Options page, select one of three options under Run Graph View Scope: Fit To
Screen, Auto Scroll, or Manual Scroll. The default is Fit To Screen. Then select OK.
Graphing Data for a Previously Completed Run
1
Select the Run History button on the side menu of the Home page.
Figure 4.6 Run History Button
4-12
2
On the Run History page, select the Date of the run from the left column.
3
Select the Graph tab at the bottom of the page.
4
On the Historical Run Data page, select Options.
PN B38322AB
Configuration
Managing Reports
5
On the Run Graph Options page, choose one of three options: Fit To Screen, Auto Scroll, or Manual
Scroll. (Fit To Screen is the default.) Then select OK.
Figure 4.7 Run Graph Options
Print Data
You can print run history from the Run Graph page or the Run History page.
NOTE You must have Administrator access to configure the printer.
Printing Run History from the Run Graph Page
1
After the run is completed, select the Run Graph button from the side menu on the Home page.
Figure 4.8 Run Graph Button
2
3
PN B38322AB
On the Real-Time Run Data page, select the Options tab.
On the Run Graph Options page, choose one of three options: Fit To Screen, Auto Scroll, or Manual
Scroll. (Fit To Screen is the default.) Then select OK.
4-13
4
Configuration
Managing Reports
4
Select the Print button. The system sends the run graph to the printer configured by the
Administrator.
Printing RunHistory from the Run History Page
1
Select the Run History button from the side menu of the Home page.
Figure 4.9 Run History Button
2
3
Use filtering to display the run histories you want to print.
Select the Print button. The system sends the run history for all currently listed runs to the
printer configured by the Administrator.
Export Data
Run history data can be manually exported to an external media source, such as a USB drive, or
automatically exported to a network.
NOTE You must have Administrator access to configure the network to automatically export data.
Manually Exporting Run History Data to a USB Drive
IMPORTANT Before manually exporting, use the Setup Network page to configure network settings. See
Setting Up the Network for more information.
1
Select the Run History button on the side menu of the Home page.
Figure 4.10 Run History Button
4-14
PN B38322AB
Configuration
Managing Reports
2
On the Run History page, use filtering to display the run histories you want to export, then select
the Export button.
Figure 4.11 Run History
3
4
On the Export Run History page, the system displays a prompt to insert the USB drive.
When the system reads the USB drive, select it from the Available Drives list, and select the
Export button.
The Avanti JXN series will then export the currently listed run histories to the USB drive.
Manually Exporting Run History Data to a Mapped Network
IMPORTANT Before manually exporting, use the Setup Network page to configure network settings. See
Setting Up the Network for more information.
1
Select the Run History button on the side menu of the Home page.
Figure 4.12 Run History Button
2
PN B38322AB
On the Run History page, use filtering to display the run histories you want to export, then select
the Export button.
4-15
4
Configuration
Managing Reports
3
On the Export Run History page, select the network from the Available Drives list, then select the
Export button.
Auto Print and Auto Export Run History Data
A user with Administrator access can configure the Avanti JXN series to automatically print run
history data. The Avanti JXN series can also be configured to automatically export run history data
to a previously configured network. Run history data automatically sent to a network is generated
as a .csv file (a simple spreadsheet format) and an .xml file (a simple, structured text format).
IMPORTANT Before you enable Auto Export, check with your network administrator to make sure you have
write permission to a folder where the automatically exported run history data can be stored.
Enabling Auto Print
1
Select the Menu button on the Header Bar to display the Menu page.
2
Select the Options button.
3
Select the Reports tab.
4
Select the Auto Print button.
The small box in the Auto Print button will turn green to indicate it is enabled.
When a run is completed, the Avanti JXN series will automatically print the run history data to
the printer previously configured to the program.
5
To deactivate the Auto Print function, follow the previous four steps.
The small box in the Auto Print button will turn grey to indicate it is disabled.
Enabling Auto Export
IMPORTANT Before you enable Auto Export, uses the Setup Network page to configure network settings.
See Setting Up the Network for more information.
1
4-16
Select the Menu button on the Header Bar to display the Menu page.
PN B38322AB
Configuration
Managing Reports
2
Select the Options button.
3
Select the Reports tab.
4
Select the Auto Export button.
The small box in the Auto Export button will turn green to indicate it is enabled.
When a run is completed, the instrument automatically exports the run history data to the
network (if previously configured) as a .csv file (a simple text spreadsheet) and an .xml file (a
simple, structured text format).
5
To deactivate the Auto Export function, follow the previous four steps.
The small box in the Auto Export button will turn grey to indicate it is disabled.
Enabling Run Comments
The Run Comments function enables the user to add comments to the run log before and after the
end of a run.
1
On the Home page, click on Menu icon.
2
Select Options.
3
Select the Reports tab.
4
Select the Run Comments button.
The small box in the Run Comments button will turn green to indicate it is enabled.
5
To deactivate the Run Comments function, follow the previous four steps.
The small box in the Run Comments button will turn grey to indicate it is disabled.
Using Run Comments
1
PN B38322AB
Select the Start button to begin a run.
4-17
4
Configuration
Managing Reports
2
The system displays the Before Run Comment page. Enter a comment and select OK to start the
run. You can leave the comment field blank, but you must select OK to start the run. If you select
Cancel, the run will not start.
Figure 4.13 Before Run Comment
3
When the run stops or you select the Stop button, the system displays the After Run Comment
page. Enter a comment, and select OK.
The comments appear in the Summary tab of the Run History page.
E-Signature
The E-Signature function permits a user to electronically add a signature and add a note (if desired)
to run history data after the run is complete.
NOTE You must have Administrator access to enable E-Signature. You must also have Require Login enabled.
Enabling E-Signatures
1
On the Home page, select the Menu button.
2
Select the Options button.
3
Select the Reports tab.
4
Select the E-Signature button.
The small box in the E-Signature button will turn green to indicate it is enabled.
4-18
PN B38322AB
Configuration
Managing Reports
5
To disable the E-Signature function, follow the previous four steps.
The small box in the E-Signature button will turn grey to indicate it is disabled.
Using E-Signature
1
After a run is complete, select the Run History button on the side menu of the Home page.
2
On the Run History page, select the run to which comments will be added.
3
Select the Signature tab.
4
In the Sign As box, select Author, Reviewer, or Approver.
NOTE You can select the Author option only if you started the run. You must have Super User or
Administrator access to select Reviewer or Approver.
Figure 4.14 Signature
5
Select Sign or Add Note.
a. If you select Sign, the system displays the Sign page. Enter your PIN and select OK.
The system adds the E-Signature to the Summary on the Run History Page. See the Run
History Page for more information.
b. If you select Add Note, the system displays the Add Note page. Enter the note, then select
Sign. The system displays the Sign page. Enter your PIN and select OK.
PN B38322AB
4-19
4
Configuration
Managing Reports
The note and E-Signature will be added to the Summary on the Run History page. See the
Run History Page for more information.
4-20
PN B38322AB
CHAPTER 5
Programs
Overview
The Avanti JXN series includes the functionality to create and store programs in the centrifuge
memory. A program is a series of steps containing parameters for a run. Programs are retained in
the centrifuge memory until they are deleted.
This chapter contains information about:
• Creating Programs
• Running Programs
• Editing Programs
• Deleting Programs
PN B38322AB
5-1
Programs
Creating Programs
Creating Programs
Creating Programs
1
Select Program from the side menu on the Home page.
NOTE When Require Login is enabled, programs can only be created by an Administrator or Super User.
Figure 5.1 Program Button
Figure 5.2 Home
5-2
PN B38322AB
Programs
Creating Programs
2
On the Select Program page, select the New button.
Figure 5.3 Select Program
3
On the New Program page, •Unnamed• appears as the title. To name the new program now,
select •Unnamed• on the screen.
Figure 5.4 Unnamed program
PN B38322AB
5-3
5
Programs
Creating Programs
4
On the New Program Name page, use the keyboard to name it, then select OK to save it.
NOTE Program names cannot be reused.
Figure 5.5 New Program Name
5
On the New Program page, select the Accel Decel button to set the Acceleration and Deceleration
profiles. On the Acceleration/Deceleration Profiles page, set the profiles, then select OK to save
them and return to the previous page.
Figure 5.6 Set Acceleration/Deceleration Profiles
5-4
PN B38322AB
Programs
Creating Programs
6
To specify the rotor, select the Rotor button. The system displays rotor types. Select a rotor.
When you are finished making your selection, select OK to save them and return to the previous
page.
NOTE Specifying a rotor type is optional. However, if a rotor type is selected within the program editor,
this constrains the other program settings and the rotor instance selected for the run.
Figure 5.7 Select Rotor
7
On the New Program page, select the New Step button.
Figure 5.8 New Step
PN B38322AB
5-5
5
Programs
Running Programs
a. Select the Set Speed button at the top of the page, then use the keypad to set the speed. The
speed must be at least 500 RPM up to the maximum speed for the selected rotor. If you plan
to set the speed in units of relative centrifugal field (RCF), select the RPM/RCF button.
NOTE The RPM/RCF button is only enabled when you have selected a rotor.
b. Select the Set Time button, then use the keypad to set the time range. The run time must
be between 1 minute and 99 hours 59 minutes.
c. Select the Set Temp button, then use the keypad to set the temperature.
d. When the parameters for Speed, Time, and Temperature are set, select OK to save the step
and return to the New Program page.
8
The new step appears in a numbered sequence for the run. From this point, more steps can be
added to the run, edited, or deleted using the New Step, Edit Step, and Delete Step buttons.
Figure 5.9 New Step in a numbered sequence
9
Select Save to store the program.
Running Programs
NOTE If Require Login is enabled, the user needs to be authorized to run the programs. Users will only be
able to see the programs they are authorized to run.
5-6
PN B38322AB
Programs
Editing Programs
Running Programs
1
Select Program from the side menu on the Home page.
Figure 5.10 Program Button
2
On the Select Program page, choose the program you want to run, then select OK.
NOTE The list will only show the programs that are authorized for use by the user.
3
Select the Start button. The run program begins.
NOTE You must select a compatible rotor from the Rotor Library in order to enable the Start button. If
the program specifies a rotor type, that further constrains the set of valid rotors you can choose from.
NOTE You must have Super User or Administrator access to change a run in progress. If you select the
Set Speed, Set Time, or Set Temp buttons to change the parameters while a program is running, the
system displays a message that you cannot change parameter values for the selected program. It
will ask if you want to exit the program and run with the changes, in which case, the remaining steps
in the program will NOT be run.
4
To stop the run for any reason, select the Stop button.
Editing Programs
You must have Administrator or Super User access to modify any part of a program, which includes
the Steps, Acceleration/Deceleration rates, and Rotor. You can edit a program only when it is not
running.
Editing a Program
1
Select Program from the side menu on the Home page.
Figure 5.11 Program Button
PN B38322AB
5-7
5
Programs
Deleting Programs
2
3
4
5
Select the program you want to edit and select the Edit button. If the program is selected to run,
that selection will be cleared. If the program is running, the Edit button will be disabled.
On the Edit Program page, select the numbered step you want to edit, then select the Edit Step
button.
On the Edit Step page, select each button you want to modify (Set Speed, Set Time, and Set
Temp), then select the Clear button and enter the new parameters. Select OK to save the
changes and return to the previous page.
On the Edit Program page, you can select the Accel Decel button and/or the Rotor button, and
modify each set of parameters. Then select Save.
Deleting Programs
You can delete any program that is not currently running.
NOTE If Require Login is enabled, only an Administrator or Super User may delete a program.
1
On the Home page, select Program from the side menu.
Figure 5.12 Program Button
2
3
On the Select Program page, select the program you want to delete, then select the Delete
button.
The system displays a confirmation message. Select Yes to delete the program, or select No to
cancel the deletion.
NOTE A deleted program name cannot be reused.
5-8
PN B38322AB
CHAPTER 6
Functional Pages
Overview
This chapter describes the functional pages used to control the Avanti JXN series. They include all
of the following:
• Home Page
• Home Page (Run in Progress)
• Set Speed Page
• Select Rotor Page (Library)
• Set Time Page
• Delay Start Page
• Set Speed ω²t Time Page
• Set Temperature Page
• Set Acceleration/Deceleration Profiles Page
• Login Page
• Select Program Page
• New/Edit/View Program Page
• Select Rotor Page (Catalog)
• New/Edit Step Page
• Program Log Page
• Export Page
• Authorize Users Page
• Import Page
• Real-Time Run Data/Historical Run Data Page
• Run Graph Options Page
• Run History Page
• Run History Filter Page
• Before Run/After Run Comment Page
• Menu Page
• System Options Page
PN B38322AB
6-1
Functional Pages
Overview
• Select Language Page
• User Options Page
• Max Temperature Offset Page
• Reset User PIN Page
• Select Image Page
• Set Date and Time Page
• System Log Page
• Manage Rotors Page
• Add to Rotor Library Page
• Diagnostic History Page
• Set Sound Page
• Custom Sounds Page
• Archive Data Page
• Setup Network Page
• Select Printer Page
• Setup Email Page
• Setup VNC Page
• Manage Users Page
• Add/Edit User Page
• Authorize Programs Page
• Rotor Catalog Page
• About Page
• Zonal Authorization Page
• Zonal Operation Page
6-2
PN B38322AB
Functional Pages
Home Page
Home Page
Figure 6.1 Home Page
The Home page is the first operational page to appear after the instrument startup. To display the
Home page, select the Home page button on the Header Bar. It is the basic page from which you
begin most operations. The large fields are designed for viewing from a distance.
You can select the Home page button to return to the Home page.
In addition to the Header Bar and the Footer Bar, the Home page contains the following elements:
• The w²t Display.
The w²t Display appears only when you have enabled w²t mode on the System Options Page.
It shows the accumulated w²t value for the run in progress. See the Set Speed ω²t Time Page for
details.
• The Set Speed Display/Button.
The Set Speed Display/Button shows the current rotor speed as a large number and also shows
the current run speed setting in small characters across the bottom. Select the Set Speed
Display/Button to display the Set Speed Page (or the Set Speed ω²t Time Page if the w²t mode
is active). When you are not on the Home page, the Set Speed Display/Button appears in the
Footer Bar.
• The Set Time Display/Button.
The Set Time Display/Button shows the current remaining run time as a large number and also
shows the current run duration setting in small characters across the bottom. Before you begin
a run, the numbers are the same. During a run, the large number counts down to zero.
NOTE In Hold mode, the time counts up to show the length of time the instrument has been running,
and continues to increment until you select Stop or the maximum run time elapses. When a delayed
run is scheduled or pending, the time counts down to the effective start time of the run.
PN B38322AB
6-3
6
Functional Pages
Home Page
Select the Set Time Display/Button to display the Set Time Page (Set Speed ω²t Time Page if the
w²t mode is active). When you are not on the Home page, the Set Time Display/Button appears
in the Footer Bar.
• The Set Temp Display/Button.
The Set Temp Display/Button shows the current temperature as a large number and also shows
the current temperature setting in small characters across the bottom. Select the Set Temp
Display/Button to display the Set Temperature Page. When you are not on the Home page, the
Set Temp Display/Button appears in the Footer Bar.
• The Side Menu
The Side Menu must be accessed from the Home page, and includes the following buttons:
— If your system requires login, the Login/Logout button. Select this button to log in or out of
the system.
— The Program button. Select this button to display the Select Program Page.
— The Run Graph button. Select this button to display the Real-Time Run Data/Historical Run
Data Page.
— The Run History button. Select this button to display the Run History Page.
— The Zonal Mode button. Select this button to display the Zonal Authorization Page.
• The Rotor Display/Button
The Rotor Display/Button on the Footer Bar shows the current selected rotor. Select this button
to display the Select Rotor Page (Library).
IMPORTANT Zonal mode is used when the JCF-Z continuous flow/zonal rotor is installed.
When you use Zonal mode, the Zonal Operation Page replaces the Home page.
6-4
PN B38322AB
Functional Pages
Home Page (Run in Progress)
Home Page (Run in Progress)
Figure 6.2 Home Page (Run in Progress)
When an actual run is in progress, the Home page includes the following information:
• The Set Speed Display shows the actual speed of the rotor in RPM or RCF.
• The Set Time Display shows the time remaining in the run or the present step of the run
program. If the time setting is Hold, it displays the actual run time elapsed.
• The Set Temp Display shows the current actual temperature of the run in degrees Celsius.
Animated arrows on each display show whether the speed, time and temperature are increasing or
decreasing.
PN B38322AB
6-5
6
Functional Pages
Set Speed Page
Set Speed Page
Figure 6.3 Set Speed Page (Rotor Selected)
To set the speed for the next run or change the speed of the run in progress, select the Set Speed
Display/Button on the Home Page or the Footer Bar to display the Set Speed page. You can select
the RPM RCF button to set the value in RCF (Relative Centrifugal Field) instead of RPM.
If the instrument is in w²t mode, the system displays the Set Speed ω²t Time Page.
In addition to the Header Bar and the Footer Bar, the Set Speed page contains the following
elements:
• The Set Speed Display at the top of the page shows the current Set Speed in RPM or RCF. The
last digit is always zero.
• The keypad changes the speed setting. You can use the Clear and Back keys to make corrections.
• The RPM/RCF button selects the speed units. This button is disabled until a rotor is selected.
• The Select Rotor button displays the Select Rotor Page (Library) page.
• The Cancel button discards your changes and dismisses the page.
• The OK button saves your entry and dismisses the page.
6-6
PN B38322AB
Functional Pages
Select Rotor Page (Library)
Select Rotor Page (Library)
Figure 6.4 Select Rotor Page (Library)
To select a rotor for the next run, select the Rotor Display/Button on the Home Page or the Select
Rotor button on either the Set Speed Page or the Set Speed ω²t Time Page to display the Select Rotor
page. This page displays the library of rotors that have been entered for your instrument.
In addition to the Header Bar and the Footer Bar, the Select Rotor page contains the following
elements:
• The Rotor Library List shows the available rotors for the instrument. Select a rotor from this
list. You must select a rotor before you can start a run.
• The Cancel button cancels your selection and dismisses the page.
• The OK button saves the selection and dismisses the page.
For details about each rotor, see the Rotor Catalog Page.
PN B38322AB
6-7
6
Functional Pages
Set Time Page
Set Time Page
Figure 6.5 Set Time Page
To set the duration for the next run or change the duration of the run in progress, select the Set
Time Display/Button on the Home Page or the Footer Bar to display the Set Time page.
If the instrument is in w²t mode, the Set Speed ω²t Time Page appears instead.
In addition to the Header Bar and the Footer Bar, the Set Time page contains the following elements:
• The Set Time Display shows the current Set Time setting in hours and minutes.
• The keypad changes the time setting. You can use the Clear and Back keys to make corrections.
• The Hold key sets the time to a hold state with no countdown to an automatic end. When you
select Hold, the run does not end until you select Stop (or until the maximum time of 99 hours
and 59 minutes has elapsed).
• The Delay Start button displays the Delay Start Page, to set a future time at which to start or end
the run. This button is disabled when a run is in progress or a delayed run is pending. (To stop
the countdown on a pending delayed run, go to the Delay Start Page and select No Delay.)
• The Cancel button discards your entry and dismisses the page.
• The OK button accepts your entry and dismisses the page.
6-8
PN B38322AB
Functional Pages
Delay Start Page
Delay Start Page
Figure 6.6 Delay Start Page
To set a future start or end time for the next run, select the Delay Start button on the Set Time Page
or the Set Speed ω²t Time Page to display the Delay Start page.
In addition to the Header Bar and the Footer Bar, the Delay Start page contains the following
elements:
• The current time in hours and minutes and the length of time currently set for the run.
• The No Delay button (default) sets the run start time to the present and disables the Date/Time
scroll arrows.
• The Start At button enables the Date/Time scroll arrows and sets the run to start at the time
entered.
• The Stop At button enables the Date/Time scroll arrows and sets the run to end at the time
entered. The system calculates the start time by subtracting the Run time from the Stop At
time.
NOTE The Stop At feature is not available for a Hold run.
• The Date/Time scroll arrows change the date or time setting.
• The Cancel button discards your entry and dismisses the page.
• The OK button accepts your entry and dismisses the page.
PN B38322AB
6-9
6
Functional Pages
Set Speed ω²t Time Page
Set Speed ω²t Time Page
Figure 6.7 Set Speed ω²t Time Page
When the ω²t mode is active and you select either the Set Speed button or the Set Time button on
the Home Page or the Footer Bar, the system displays the Set Speed ω²t Time page. The ω²t value is
computed from the time and RPM (or RCF) values you enter. Use this page to set the values for the
next run that produce the desired ω²t value.
Use the ω²t Mode button on The Basic Tab of the System Options Page to enable or disable ω²t mode.
In addition to the Header Bar and the Footer Bar, the Set Speed ω²t Time page contains the following
elements:
• The Set Speed Display/Button shows the current Speed in RPM or RCF. Select this button to set
a new speed value. The system then changes the ω²t or time value, whichever you entered last,
to reflect the new speed value.
• The Set ω²t Display/Button shows the current ω²t value. Select this button to set a new ω²t
value. The time then changes to reflect the new ω²t value.
• The Set Time Display/Button shows the current time setting in hours and minutes. Select this
button to set a new time value. The ω²t value then changes to reflect the new time value.
• Use the RPM/RCF button to select the speed units. You must have a rotor selected to use RCF.
• The Select Rotor button displays the Select Rotor Page (Library).
• The keypad changes slightly depending on the value you are entering. For setting time, you can
use the Hold key to set the time to a hold state with no countdown to an automatic end. For
Display/Button setting ω²t, use the decimal and e keys to enter values in exponential notation.
You can use the Clear and Back keys to make corrections.
• The Delay Start button displays the Delay Start Page.
• The Cancel button discards your changes and dismisses the page.
• The OK button accepts your changes and dismisses the page.
6-10
PN B38322AB
Functional Pages
Set Temperature Page
Set Temperature Page
Figure 6.8 Set Temperature Page
To set the temperature for the next run or change the temperature for the run in progress, select
the Set Temperature button on the Home Page or the Footer Bar to display the Set Temperature
page.
In addition to the Header Bar and the Footer Bar, the Set Temperature page contains the following
elements:
• The Set Temperature Display shows the current Set Temperature setting in degrees Celsius.
• Use the keypad to change the temperature setting. You can use the Clear and Back keys to make
corrections.
• The Cancel button discards your changes and dismisses the page.
• The OK button accepts your changes and dismisses the page.
PN B38322AB
6-11
6
Functional Pages
Set Acceleration/Deceleration Profiles Page
Set Acceleration/Deceleration Profiles Page
Figure 6.9 Set Acceleration/Deceleration Profiles Page
To choose profiles for acceleration and deceleration, select the Accel/Decel Display/Button in the
Footer Bar of the Home Page to display the Set Acceleration/Deceleration Profiles page.
In addition to the Header Bar and the Footer Bar, the Set Acceleration/Deceleration Profiles page
contains the following elements:
• Use Acceleration to select a numbered acceleration value.
• Use Deceleration to select a numbered deceleration value.
• The Cancel button discards your changes and dismisses the page.
• The OK button accepts your changes and dismisses the page.
The acceleration values are the degree of reduction from the maximum value. The acceleration
value of zero is the maximum (no reduction). The acceleration value of 10 is the slowest (maximum
reduction). The same applies to the deceleration values. The value 11 is an absolute reduction,
eliminating all braking and allowing the rotor to coast to a stop.
Slower (numerically higher) acceleration and deceleration values minimize sample-to-gradient
interface disturbance. Each acceleration profile has a designated time that it takes to reach a
specified speed. After that, it uses maximum acceleration to reach run speed. For a deceleration
profile, the instrument uses maximum deceleration until it reaches the specified speed, then takes
the designated time to slow to a stop.
6-12
PN B38322AB
Functional Pages
Login Page
Example Acceleration and Deceleration Settings
The values associated with each acceleration and deceleration setting are given in the table below.
Table 6.1 Acceleration and Deceleration Profiles
Setting
Description
Maximum acceleration (not available
with the JS-24.38 and JS-24.15 rotors)
Full torque is used from 0 RPM until set speed is reached.
Timed acceleration
Acceleration time from 0 to 500 RPM can be set from 1 to 10
minutes. Above 500 RPM, full torque is used until set speed is
reached.
Maximum deceleration
Full brake from set speed to near 0 RPM. Reduce brake is used
during the last few RPM until 0 is reached to minimize sample
disturbance.
Timed deceleration
Full brake from set speed to 500 RPM. From 500 to 0 RPM,
deceleration time can be set from 1 to 10 minutes.
Coast
No brake is used. Rotor coasts from set speed to 0 RPM. The time
required for a rotor to come to a complete stop can vary from 1 to
9 hours depending upon the set speed while in operation and the
rotor’s mass.
Login Page
Figure 6.10 Login Page
If the user login requirement has been enabled for the instrument, you must log in to the system
use it. Select the Login button on the Home Page to display the Login page.
PN B38322AB
6-13
6
Functional Pages
Select Program Page
To enable or disable the user login requirement, select Require Login on The Users Tab of the System
Options Page.
NOTE Only an Administrator can change this setting.
• To log in, select your User ID from the list on the left. Use the keypad to enter your PIN on the
right, and select Login.
• Select Cancel to dismiss the page without logging in.
Select Program Page
Figure 6.11 Select Program Page
To select or manage your run programs, select the Program button on the Home Page to display the
Select Program page. Operator-level users may only view and run programs.
In addition to the Header Bar and the Footer Bar, the Select Program page contains the following
elements:
• Select a program from the list on the left to run, edit, view, delete, authorize users, and view
program log. Select •No Program• and select OK to return to manual mode.
• Select New to create a new program. The system displays the New Program Page.
• Select Edit to change the selected program. The system displays the Edit Program Page.
• Select View to review the selected program without making changes to it. The system displays
the View Program Page.
• Select Delete to remove the selected program from the list. The system displays a confirmation
message. Select Yes to remove the program.
• Select Program Log to display the Program Log Page for the selected program.
6-14
PN B38322AB
Functional Pages
New/Edit/View Program Page
• Select Authorize Users to grant Operator-level users permission to run the selected program.
The system displays the Authorize Users Page.
• Select the Cancel button to discard your changes and dismiss the page.
• Select Print to print the selected program.
• Select Export to export the selected program. The system displays the Export Page.
• Select Import to import a program. The system displays the Import Page.
• The OK button accepts your program selection and dismisses the page. The system will run the
selected program when you select Start.
New/Edit/View Program Page
Figure 6.12 New Program Page
Figure 6.13 Edit Program Page
PN B38322AB
6-15
6
Functional Pages
New/Edit/View Program Page
Figure 6.14 View Program Page
To create a run program, select the New button on the Select Program Page to display the New
Program page. To edit or view a run program, select the program and select the Edit or View button
on the Select Program Page to display the Edit Program or View Program page. The pages are
identical except for which buttons are active. (The View Program page does not permit editing.)
In addition to the Header Bar and the Footer Bar, the New/Edit/View Program page contains the
following elements:
NOTE No changes can be made on the View Program page.
• The program name appears at the top of the page. New programs appear as •Unnamed• until
you save them, or select •Unnamed• to display the New Program Name page. Enter the name of
the new program and select OK to enter the name.
• Program steps appear in the Step List.
• Acceleration and Deceleration Profiles appear in the Accel/Decel area. Select the Accel/Decel
button to display the Set Acceleration/Deceleration Profiles Page to select new profiles.
• The selected rotor type appears in the Rotor area. To enter or change the rotor, select the Rotor
button to display the Select Rotor Page (Catalog).
• Use the New Step button to display the New Step Page and add a new step to the program.
• To change a step, select the step and select the Edit Step button to display the Edit Step Page.
• To delete a step, select the step and select the Delete Step button. The system displays a
confirmation message. Select Yes to delete the step.
• The Cancel button discards your changes and dismisses the page.
• From the Edit Program page, you can use the Save As button to save the changed program as a
new program. The system displays the New Program Name page. Enter the name of the new
program and select OK to save the program. The original program remains unchanged.
• The Save button saves your entry and dismisses the page.
6-16
PN B38322AB
Functional Pages
Select Rotor Page (Catalog)
Select Rotor Page (Catalog)
Figure 6.15 Select Rotor Page (Catalog)
To select a type of rotor for a run program, select the Rotor button on the New Program Page or the
Edit Program Page to display the Select Rotor page (Catalog). This page displays the complete list of
rotors that can be used with the Avanti JXN series.
In addition to the Header Bar and the Footer Bar, the Select Rotor page contains the following
elements:
• The Rotor Catalog List shows the rotors that can be used with the instrument. Select a rotor
from this list to indicate the kind of rotor that must be used with the run program. When you
run the program, the selection from the rotor library will be restricted to rotors of the same
kind.
• The Cancel button cancels your selection and dismisses the page.
• The OK button saves the selection and dismisses the page.
For details about each rotor, use the Rotor Catalog Page.
PN B38322AB
6-17
6
Functional Pages
New/Edit Step Page
New/Edit Step Page
Figure 6.16 New Step Page
Figure 6.17 Edit Step Page
To create a step within a run program, select the New Step button on the New Program Page or the
Edit Program Page to display the New Step page. To edit a step within a run program, select the step
and select the Edit Step button on the New Program Page or the Edit Program Page to display the
Edit Step page. The pages contain the same options.
In addition to the Header Bar and the Footer Bar, the New/Edit Step page contains the following
elements:
• The Set Speed field shows the default or the current step Set Speed in RPM. The last digit is
always zero. Select the field and use the keypad to change the entry as required. If you plan to
set the speed in units of relative centrifugal field (RCF), select the RPM/RCF button.
NOTE The RPM/RCF button is only enabled when you have selected a rotor.
6-18
PN B38322AB
Functional Pages
Program Log Page
• The Set Time field shows the default or the current step Set Time in hours and minutes. Select
the field and use the keypad to change the entry as required.
• The Set Temp field shows the default or current step Set Temperature setting in degrees
Celsius. Select the field and use the keypad to change the entry as required.
• Use the keypad to change the settings as required. You can use the Clear and Back keys to make
corrections.
• The Cancel button discards your changes and dismisses the page.
• The OK button saves your entry and dismisses the page.
Program Log Page
Figure 6.18 Program Log Page
To display the history of changes to a run program, select the program and select the Program Log
button on the Select Program Page to display the Program Log page for the selected program.
In addition to the Header Bar and the Footer Bar, the Program Log page contains the following
elements:
• The name of the selected program appears at the top of the page.
• The log entry section lists all versions of the selected program.
• Select a version of the program and select View Program to display the View Program Page for
the selected version.
• Select a version of the program and select Export Program to export the selected version. The
system displays the Export Page.
• Select an older version of the program and select Make Active to copy the selected version. The
copy becomes the most current version of the program.
PN B38322AB
6-19
6
Functional Pages
Export Page
• Select the Back button to return to the Select Program Page.
• Select Print to print the program log.
• Select Export to export the program log. The system displays the Export Page.
Export Page
Figure 6.19 Export Page
Different kinds of information can be exported from the Avanti JXN series to a USB device or
network drive. All Export pages function in the same manner.
NOTE Do not remove a USB drive while a data transfer is in progress.
In addition to the Header Bar and the Footer Bar, the Export page contains the following elements:
• The Export Item at the top tells you what you are about to export (About information,
diagnostic messages, programs, the program log, run history, or the system options log).
• The Available Drives list shows all the available network and USB drives. Attach a USB device if
necessary. Select the destination drive.
• The Back button returns to the previous page without exporting information.
• The Export button copies the information to the selected drive.
6-20
PN B38322AB
Functional Pages
Authorize Users Page
Authorize Users Page
Figure 6.20 Authorize Users Page
To manage the list of users with permission to run a program, select the program and select the
Authorize Users button on the Select Program Page to display the Authorize Users page.
In addition to the Header Bar and the Footer Bar, the Authorize Users page contains the following
elements:
• The program name appears at the top of the page.
• The list box displays the Operator-level users in the system. Users with permission to run the
program are highlighted.
• To grant permission to additional users, select the users.
• To remove permission for all users, select Clear All Users.
• To grant permission to all current users, select Authorize All Users.
• Select the Cancel button to discard your changes and return to the Select Program Page.
• Select the OK button to accept your changes and return to the Select Program Page.
PN B38322AB
6-21
6
Functional Pages
Import Page
Import Page
Figure 6.21 Import Page
Many kinds of information can be imported to the Avanti JXN series from a USB device or network
drive. All Import pages function in the same manner.
NOTE Do not remove a USB drive while a data transfer is in progress.
In addition to the Header Bar and the Footer Bar, the Import page contains the following elements:
• The Import Item at the top tells you what you are about to import (images, programs, custom
sound files).
• The Available Drives list shows all the available network and USB drives. Attach a USB device if
necessary. Select the appropriate drive.
• Select Refresh to update the file list of the selected drive.
• When you select a drive, the system displays the available files on the right. Select the file to
import.
• The Back button returns to the previous page without importing information.
• The Import button imports the selected file.
6-22
PN B38322AB
Functional Pages
Real-Time Run Data/Historical Run Data Page
Real-Time Run Data/Historical Run Data Page
Figure 6.22 Real-Time Run Data Page
Figure 6.23 Historical Run Data Page
Select the Run Graph button on the side menu of the Home Page to display the Real-Time Run Data
page. This page graphs the current run as it is in progress, or shows the most recent run.
PN B38322AB
6-23
6
Functional Pages
Run Graph Options Page
Figure 6.24 Run Graph Button
Select a run log from the Run History Page and select the Graph button to display the Historical Run
Data page for the selected run.
In addition to the Header Bar and the Footer Bar, the Real-Time Run Data page contains the
following elements:
• The Back button returns to the previous page.
• The Options button displays the Run Graph Options page.
• The Print button prints the graph.
Run Graph Options Page
Figure 6.25 Run Graph Options Page
Select the Options button on the Real-Time Run Data/Historical Run Data Page to display the Run
Graph Options page. Use this page to configure scroll options for your run graph.
In addition to the Header Bar and the Footer Bar, the Run Graph Options page contains the following
elements:
• The Fit To Screen button displays the entire run on the run graph page.
• The Auto Scroll button displays the last 10 minutes of the historical run or the run in progress,
and cannot be scrolled back.
6-24
PN B38322AB
Functional Pages
Run History Page
• The Manual Scroll button displays the last 10 minutes of the run, with a scroll bar beneath the
run graph to scroll through the entire run.
• Select the Cancel button to discard your changes and return to the previous page.
• Select the OK button to accept your changes and return to the previous page.
Run History Page
Figure 6.26 Run History Page
PN B38322AB
6-25
6
Functional Pages
Run History Page
Figure 6.27 Run History Page (E-Signature Enabled)
Select the Run History button on the side menu of the Home Page to display the Run History page.
Figure 6.28 Run History Button
In addition to the Header Bar and the Footer Bar, the Run History page contains the following
elements:
• The run logs for all instrument runs are listed on the left. Select a run log to review.
• The Summary tab shows summary details for the selected run.
• The Details tab shows detailed information for each step of the selected run.
• If your system has E-Signature enabled (see The Reports Tab), use the Signature tab to sign off
on the run as the Author, Reviewer, or Approver. You must select a role to enable the Add Note
and Sign buttons. Active options are determined by your user level. The Signature tab contains
the following elements:
— Select Author to sign the run log as the author.
— Select Reviewer to sign the run log as the reviewer.
— Select Approver to sign the run log as the approver.
— You can optionally select Add Note to display the Add Note page. Enter your note and select
Sign to display the Sign page. Enter your PIN and select OK to sign the run and display the
Run History page.
— Select Sign to display the Sign page. Enter your PIN and select OK to sign the run and display
the Run History page.
• The Back button returns to the previous page.
6-26
PN B38322AB
Functional Pages
Run History Filter Page
• The Filter button displays the Run History Filter Page.
• The Print button prints all the listed run logs. (Use Filter to narrow the list.)
• The Graph button displays the Historical Run Data Page for the selected run log.
• The Export button exports all the listed run logs. (Use Filter to narrow the list.) The system
displays the Export page.
Run History Filter Page
Figure 6.29 Run History Filter Page
Select the FIlter button on the Run History Page to display the Run History Filter page. Use this page
to narrow the parameters for the run logs that will be displayed, printed or exported on the Run
History Page.
In addition to the Header Bar and the Footer Bar, the Run History Filter page contains the following
elements:
• The Filter by User button enables the user list. Select a user from the list to limit the run log
display to the runs performed by the selected user.
• The Filter by Date button enables the From and To fields. Select the fields to display the Set Date
pages and enter a date range to which to limit the run log display.
• Select the Cancel button to discard your entries and return to the Run History Page.
• Select the OK button to accept your entries and return to the Run History Page.
PN B38322AB
6-27
6
Functional Pages
Before Run/After Run Comment Page
Before Run/After Run Comment Page
Figure 6.30 Before Run Comment Page
If your system has Run Comments enabled (see The Reports Tab), it displays the Before Run
Comment page when you start a run, and the After Run Comment page when a run ends.
In addition to the Header Bar and the Footer Bar, the Run Comment pages contains the following
elements:
• Use the keypad to enter your comment.
• The Cancel button discards your comment and dismisses the page.
• The OK button accepts your comment and dismisses the page.
6-28
PN B38322AB
Functional Pages
Menu Page
Menu Page
Figure 6.31 Menu Page
Select the Menu button in the Header Bar to display the Menu page. Use this page to configure or use
the Avanti JXN series options.
• The Options button displays the System Options Page.
• The Rotor Catalog button displays the Rotor Catalog Page.
• The About button displays the About Page.
• The Zonal Operation button displays the Zonal Authorization Page.
• The Service Mode button is used by service personnel only. If you select this button and display
the Service Login page, select the Cancel button to dismiss the page.
• The Done button dismisses the page.
PN B38322AB
6-29
6
Functional Pages
System Options Page
System Options Page
Figure 6.32 System Options Page, Basic Tab
Select the Options button in the Menu page to display the System Options page. Use this page to
configure the system option settings.
The System Options page is organized into five tabs. If you have user login enabled, many of the
options are restricted to Admin-level users. (See the Manage Users Page for more information.) If a
button is greyed out, you do not have access to the option.
In addition to the Header Bar and the Footer Bar, the System Options page contains the following
elements organized on five tabs:
The Basic Tab
• The Select Language button displays the Select Language Page.
• The User Options button displays the User Options Page.
• The ω²t Mode button enables and disables the ω²t mode. The mode is on when the green square
is visible. See the Set Speed ω²t Time Page for details.
• The Max Temperature Offset button displays the Max Temperature Offset Page.
• The Max Temperature Shutdown button enables and disables instrument shutdown if the
maximum temperature offset is exceeded. When the green square is visible, the instrument will
stop the run in the event the maximum temperature offset is exceeded. When the green square
is not visible, the instrument will notify the user that the maximum temperature offset was
exceeded, but not shut down the run.
6-30
PN B38322AB
Functional Pages
System Options Page
The System Tab
Figure 6.33 System Options Page, System Tab
• The Set System Name button displays the Set System Name page. Enter the system name and
select OK to return to the System Options page.
• The Set Date and Time button displays the Set Date and Time Page.
• The System Log button displays the System Log Page.
• The Manage Rotors button displays the Manage Rotors Page.
• The Diagnostic History button displays the Diagnostic History Page.
• The Set Sound button displays the Set Sound Page.
• The Custom Sounds button displays the Custom Sounds Page.
• The Archive Data button displays the Archive Data Page.
PN B38322AB
6-31
6
Functional Pages
System Options Page
The Network Tab
Figure 6.34 System Options Page, Network Tab
• The Setup Network button displays the Setup Network Page.
• The Select Printer button displays the Select Printer Page.
• The Setup Email button displays the Setup Email Page.
• The Setup VNC button displays the Setup VNC Page.
• The Enable API button enables and disables the Applications Programming Interface for remote
devices. Contact your Beckman Coulter Representative for more information.
6-32
PN B38322AB
Functional Pages
System Options Page
The Users Tab
Figure 6.35 System Options Page, Users Tab
• The Manage Users button displays the Manage Users Page.
• The PIN Expiration button displays the PIN Expiration Page. Enter the number of days that you
want PINs to remain valid. To disable PIN Expiration, enter 0 and select OK to return to the
System Options Page.
NOTE The PIN Expiration Page allows you to configure the amount of time before the PIN expires.
• The Require Login button enables and disables the user login requirement.
• The Logout Timer button displays the Logout Timer page. Change the field to the number of
minutes of inactivity before the system logs out a user. To disable the Logout Timer, enter 0 and
select OK to return to the System Options Page.
PN B38322AB
6-33
6
Functional Pages
System Options Page
The Reports Tab
Figure 6.36 System Options Page, Reports Tab
• The E-Signature button enables and disables the Signature function for run logs. See
E-Signature for more information.
• The Auto Print button enables and disables automatic printing of run logs at the completion of
each run. See Auto Print and Auto Export Run History Data for more information.
• The Email on End Run button enables and disables sending an automatic email at the conclusion
of each run. If your system is configured for email, it will send an end of run notification to the
user that initiated the run.
• The Run Comments button enables and disables the Before Run and After Run comment
requirement.
• The Auto Export button enables and disables automatic export of run logs at the completion of
each run. See Auto Print and Auto Export Run History Data for more information.
6-34
PN B38322AB
Functional Pages
Select Language Page
Select Language Page
Figure 6.37 Select Language Page
Select the Select Language button on the Basic tab of the System Options Page to display the Select
Language page. Use this page to choose the language and date, time and number format the
instrument uses in operations.
In addition to the Header Bar and the Footer Bar, the Select Language page contains the following
elements:
• The List of Languages shows all the languages and countries available for the instrument. Scroll
through this list and select a language and country.
• The Cancel button discards your selection and returns to the System Options Page.
• The OK button saves your selection and returns to the System Options Page with the
newly-selected language active on all pages.
NOTE Be careful not to select a language that you do not understand. If you don’t understand the display
language, select the Menu button, then select the upper left button (Options), select the first tab (Basic),
and then select the top button (Select Language).
PN B38322AB
6-35
6
Functional Pages
User Options Page
User Options Page
Figure 6.38 User Options Page
Select the User Options button on the Basic tab of the System Options Page to display the User
Options page. Use this page to configure personal options and information for your User ID.
NOTE You can display this page only if Require Login is enabled (see The Users Tab).
In addition to the Header Bar and the Footer Bar, the User Options page contains the following
elements:
• Select PIN to display the Reset User PIN Page.
• Select Email to display the Enter Email page. If your system is configured for email, it will send
all diagnostic messages to the address you enter. If enabled, it will also send an end of run
notification to the user that initiated the run. Select Save to return to the User Options Page.
• Select Phone Number to display the Enter Phone Number page. Enter your phone number and
select Save to return to the User Options page.
• Select the Set Avatar button to select or import an image to appear in the Footer Bar of the
Home page when you are logged on. The system displays the Select Image Page.
• Select the Set Background button to select or import an image to appear as the background in
the Footer Bar of the Home page when you are logged on. The system displays the Select Image
Page.
• The Done button dismisses the page.
6-36
PN B38322AB
Functional Pages
Max Temperature Offset Page
Max Temperature Offset Page
Figure 6.39 Max Temperature Offset Page
Select the Max Temperature Offset button on the Basic tab of the System Options Page to display the
Max Temperature Offset page. Use this page to set the tolerable deviation above the set temperature
during a run. Once the tolerable deviation above the set temperature has been selected, the user can
specify whether the run should shut down or continue if the overtemp setting is reached by using
the Max Temperature Shutdown button on the Basic tab of the System Options Page.
In addition to the Header Bar and the Footer Bar, the Max Temperature Offset page contains the
following elements:
• The Tolerable Deviation Above the Set Temperature page shows the current setting in degrees
Celsius. The system default is 4°C.
• Use the keypad to change the setting. You can use the Clear and Back keys to make corrections.
• The Cancel button discards your changes and dismisses the page.
• The OK button accepts your changes and dismisses the page.
PN B38322AB
6-37
6
Functional Pages
Reset User PIN Page
Reset User PIN Page
Figure 6.40 Reset User PIN Page
Select the PIN field on the User Options Page to display the Reset User PIN page. Use this page to
change the PIN for your User ID.
In addition to the Header Bar and the Footer Bar, the Reset User PIN page contains the following
elements:
• Enter your current PIN in the Enter PIN field.
• Enter your new PIN in the Enter new PIN field.
• Enter the same PIN in the Confirm new PIN field.
• Select the Cancel button to discard your changes and return to the User Options Page.
• Select the Save button to save your changes and return to the User Options Page.
6-38
PN B38322AB
Functional Pages
Select Image Page
Select Image Page
Figure 6.41 Select Image Page (Avatar)
Figure 6.42 Select Image Page (Background)
Select the Set Avatar button or the Set Background button on the User Options Page to display the
Select Image page. Use this page to select or import an avatar or background for your User ID on the
Avanti JXN series.
PN B38322AB
6-39
6
Functional Pages
Set Date and Time Page
In addition to the Header Bar and the Footer Bar, the Select Image page contains the following
elements:
• The Image list shows all the available avatar or background images.
• Select Import Image to import an image from a network drive or USB device. The system
displays the Import Page.
• Select the Cancel button to discard your changes and return to the User Options Page.
• Select the Save button to save your changes and return to the User Options Page.
NOTE The system supports .jpg and .png file formats. Images must be less than 50 KB for Background
Image, and 20 KB for Avatar.
Set Date and Time Page
Figure 6.43 Set Date and Time Page
Select the Set Date and Time button on System tab of the System Options Page to display the Set
Date and Time page. Use this page to set the instrument's internal time and date.
In addition to the Header Bar and the Footer Bar, the Set Date and Time page contains the following
elements:
• The Month-Day-Year controls set the date. Select the arrow buttons to increase or decrease the
numbers.
• The Hour-Minute-AM/PM controls set the time. The AM/PM value has only one arrow button
enabled at a time.
• The Select Time Format buttons set the time format. The 12 Hour format button displays a 12
hour clock with AM and PM. The 24 Hour format button displays a 24 hour clock without AM
6-40
PN B38322AB
Functional Pages
System Log Page
and PM notation. With some language/country selections, the 12 hour option may be
unavailable and the Select Time Format buttons will not be visible.
• The Cancel button discards your changes and returns to the System Options Page.
• The OK button accepts your changes and returns to the System Options Page.
System Log Page
Figure 6.44 System Log Page
To display the history of changes to the system, select the System Log button on the System tab of
the System Options Page to display the System Log page.
In addition to the Header Bar and the Footer Bar, the System Log page contains the following
elements:
• The log entry list on the left lists the date and responsible user for each system option modified.
Select an entry to display the details on the right.
• The Details section on the right shows detailed information for the selected event.
• Select the Back button to return to the System Options Page.
• Select Print to print the system log.
• Select Export to export the system log. The system displays the Export Page.
PN B38322AB
6-41
6
Functional Pages
Manage Rotors Page
Manage Rotors Page
Figure 6.45 Manage Rotors Page
To add or delete rotors from your rotor library, select the Manage Rotors button on the System tab
of the System Options Page to display the Manage Rotors page. See Managing Rotors for more
information.
In addition to the Header Bar and the Footer Bar, the Manage Rotors page contains the following
elements:
• The rotor list displays the rotors that have been added to the library.
• Select the Back button to return to the System Options Page.
• Select a rotor and select Delete to delete the rotor. The system displays a confirmation message.
Select Yes to delete the rotor.
• Select Add to add a rotor to the library. The system displays the Add to Rotor Library Page.
6-42
PN B38322AB
Functional Pages
Add to Rotor Library Page
Add to Rotor Library Page
Figure 6.46 Add to Rotor Library Page
To add a rotor to your rotor library, select the Add button on the Manage Rotors Page to display the
Add to Rotor Library page.
In addition to the Header Bar and the Footer Bar, the Add to Rotor Library page contains the
following elements:
• The Rotor Catalog list on the left lists all the rotors that are compatible with the instrument.
Select the type of rotor to add to the library.
• Select the Serial Number field to display the Enter Serial Number page. Enter the rotor serial
number and select OK to return to the Add to Rotor Library page.
• Select the Run Count field to display the Run Count page. Enter the number of times the rotor
has been used and select OK to return to the Add to Rotor Library page.
• The Cancel button discards your entry and returns to the Manage Rotors Page.
• The Save button accepts your entry and returns to the Manage Rotors Page.
PN B38322AB
6-43
6
Functional Pages
Diagnostic History Page
Diagnostic History Page
Figure 6.47 Diagnostic History Page
Select the Diagnostic History button on the System tab of the System Options Page to display the
Diagnostic History page. Use this page to review and export the details of incidents that caused a
diagnostic message on the instrument (warnings and error messages).
In addition to the Header Bar and the Footer Bar, the Diagnostic History page contains the following
elements:
• The List of Events on the left side of the screen shows all the diagnostic events for the
instrument. Scroll through this list and select an event to view the detailed information about
it.
• The Event Details on the right side of the screen shows detailed information for the selected
event.
• The Back button returns to the System Options Page.
• The Print button prints the entire diagnostic history.
• Select Export to export the entire diagnostic history. The system displays the Export Page.
6-44
PN B38322AB
Functional Pages
Set Sound Page
Set Sound Page
Figure 6.48 Set Sound Page
Select the Set Sound button on the System tab of the System Options Page to display the Set Sound
page. Use this page to set the volume and enable or disable the key click option.
In addition to the Header Bar and the Footer Bar, the Set Sound page contains the following
elements:
• The Volume buttons determines one of the four system volumes: Mute (silent), Low, Medium, or
High.
• The Key Click buttons set the key click (an audible sound for every screen touch) On or Off.
• The Cancel button discards your changes and returns to the System Options Page.
• The OK button accepts your changes and returns to the System Options Page.
PN B38322AB
6-45
6
Functional Pages
Custom Sounds Page
Custom Sounds Page
Figure 6.49 Custom Sounds Page
Select the Custom Sounds button on the System tab of the System Options Page to display the
Custom Sounds page. Use this page to import custom sounds for various system events. See Audible
Sounds for more information.
NOTE Sounds have a 10-second play limit. Files much larger than this may not be imported.
In addition to the Header Bar and the Footer Bar, the Custom Sounds page contains the following
elements:
• The system sound list shows the system events with audible notices. Select an event to review
or change the associated sound.
• Select Import to import a sound for the selected event from a network drive or USB device. The
system displays the Import Page.
• Select Delete to delete the sound associated with the selected event. The system displays a
confirmation message. Select Yes to delete the sound.
• Select Play Custom to play the custom sound associated with the selected event.
• Select Play Original to play the original sound associated with the selected event.
• Select the Done button to return to the System Options Page.
6-46
PN B38322AB
Functional Pages
Archive Data Page
Archive Data Page
Figure 6.50 Archive Data Page
Select the Archive Data button on the System tab of the System Options Page to display the Archive
Data page. Use this page to configure export of different types of system information.
NOTE Run History and Diagnostic History cannot be imported back into the system.
• The Programs button enables and disables run program export.
• The Run History button enables and disables export of run logs.
• The Diagnostic History button enables and disables the export of diagnostic messages.
• The Delete After Export button is available only when you select all three data types. Select this
button to delete the information after it has been exported.
• The Back button returns to the System Options Page.
• Select Export to export the selected information. The system displays the Export Page.
PN B38322AB
6-47
6
Functional Pages
Setup Network Page
Setup Network Page
Figure 6.51 Setup Network Page
Select the Setup Network button on Network tab of the System Options Page to display the Setup
Network page. Use this page to configure the network connection.
In addition to the Header Bar and the Footer Bar, the Setup Network page contains the following
elements:
• The Network path field is the path the instrument automatically uses for import and export.
Select the Network Path field to display the Network Path page and enter the base network path
for import and export. This should be a UNC path (e.g., \\server\sharename\folder). Select OK
to return to the Setup Network page.
• DHCP Mode (Dynamic Host Configuration Protocol) is enabled by default and automatically uses
a DHCP Server on the network to retrieve IP address values. If your network administrator
provides a specific IP address, disable DHCP mode and enter the values provided for the
following fields:
— IP Address
— Subnet Mask
— Default Gateway
— DNS Server
• The Cancel button discards your changes and returns to the System Options Page.
• The Save button accepts your changes and returns to the System Options Page.
6-48
PN B38322AB
Functional Pages
Select Printer Page
Select Printer Page
Figure 6.52 Select Printer Page
To select a printer for the system, select the Select Printer button on the Network tab of the System
Options Page to display the Select Printer page.
In addition to the Header Bar and the Footer Bar, the Select Printer page contains the following
elements:
• The Printer list shows the configured printers on the network or physically connected to the
instrument. Printers must be configured by your Beckman Coulter Representative. Select the
printer to use.
• You can select Test Print to send a test page to the selected printer.
• The Cancel button discards your selection and returns to the System Options Page.
• The Save button accepts your selection and returns to the System Options Page.
PN B38322AB
6-49
6
Functional Pages
Setup Email Page
Setup Email Page
Figure 6.53 Setup Email Page
Select the Setup Email button on the Network tab of the System Options Page to display the Setup
Email page. Use this page to configure settings for email sent from the instrument. When email is
configured, the instrument sends diagnostic notifications to all users with email addresses defined
in their user profiles.
In addition to the Header Bar and the Footer Bar, the Setup Email page contains the following
elements:
• Select the SMTP Server field to enter your email server name or address. Select OK to save the
address and return to the Setup Email page.
• The Port Number field defaults to 25. Do not change it unless required by your email server.
• User Name and Password are optional, but may be required by your email server. Select the
fields to enter the required values, then select OK to return to the Setup Email page.
• Email From defines the return email address that appears on email notifications sent by the
instrument. You can change the default to a legitimate or fictitious address, depending on your
requirements. Select the field to enter the new address, then select OK to save the address and
return to the Setup Email page.
• Select the SSL Server Enable button to enable email encryption, if necessary. The button
displays a green square when the option is enabled.
• You can select Test Email to send an email to test your configuration. Enter the recipient email
address and select OK to send the email and return to the Setup Email page. The system displays
a status message for the success or failure sending the test email. The email may still not be
delivered to the specified recipient.
• The Cancel button discards your changes and returns to the System Options Page.
6-50
PN B38322AB
Functional Pages
Setup VNC Page
• The Save button accepts your changes and returns to the System Options Page.
Setup VNC Page
Figure 6.54 Setup VNC Page
Select the Setup VNC button on the Network tab of the System Options Page to display the Setup
VNC page. Use this page to connect to the instrument from a laptop or other remote device.
• The Enable or Disable VNC Server Enable button enables or disables the VNC server.
• The Synchronize VNC Password To Logged in User PIN Enable button enables or disables using
the current user’s PIN as the VNC password.
• Select the Set Password button to set a default password. Enter and confirm the password and
select OK to save the password and return to the Setup VCN page. The system uses this password
when no user is logged in.
• The Back button returns to the System Options Page.
PN B38322AB
6-51
6
Functional Pages
Manage Users Page
Manage Users Page
Figure 6.55 Manage Users Page
To add, delete or edit your users, select the Program button on the Users tab of the System Options
Page to display the Manage Users page.
In addition to the Header Bar and the Footer Bar, the Manage Users page contains the following
elements:
• Select Add to add a new user profile. The system displays the Add User Page.
• Select a User ID and select Edit to change an existing user profile. The system displays the Edit
User Page.
• Select a User ID and select Delete to remove a user profile from the list. The system displays a
confirmation message. Select Yes to remove the user profile. User IDs cannot be re-used.
• Select a User ID and select Copy to copy the user level and permissions from the selected user
profile to a new user profile. This is helpful when you want to add a user with the same run
program permissions as an existing user. The system displays the Add User Page with the
copied information.
• Select an Operator-level User ID and select Authorize Programs to grant the user permission to
use certain run programs. The system displays the Authorize Programs Page.
• The Back button returns to the System Options Page.
6-52
PN B38322AB
Functional Pages
Add/Edit User Page
Add/Edit User Page
Figure 6.56 Add User Page
To add a user profile to the system, select the Add button on the Manage Users Page to display the
Add User page.
To edit an existing user profile, select the User ID and select Edit on the Manage Users Page to
display the Edit User page. The pages contain the same options.
In addition to the Header Bar and the Footer Bar, the Add/Edit User page contains the following
elements:
• Select the User ID field to enter a User ID for a new user profile. Select OK to return to the Add
User page.
NOTE Once you have saved the page, the User ID cannot be changed.
• Select the PIN field to set or change the PIN. Enter the new PIN in the Enter PIN field, and repeat
the same number in the Confirm PIN field. Select OK to return to the Add/Edit User page.
• Select the Email field to enter or change the user’s email. Enter or change the email address and
select OK to return to the Add/Edit User page.
NOTE If the system is configured for email, all diagnostic messages will be sent to this address.
• Select the Full Name field to enter or change the name associated with this user profile. Enter
or change the name and select OK to return to the Add/Edit User page.
• Select the Phone Number field to enter or change the user’s phone number. Enter or change the
phone number and select OK to return to the Add/Edit User page.
• Select the User Level. See Managing Users for more information.
PN B38322AB
6-53
6
Functional Pages
Authorize Programs Page
• For Operator-level user profiles, you can select the Authorize Programs button to add
permission to run programs to the user profile. The system displays the Authorize Programs
Page.
• The Cancel button discards your changes and returns to the Manage Users Page.
• The Save button accepts your changes and returns to the Manage Users Page.
Authorize Programs Page
Figure 6.57 Authorize Programs Page
To manage the list of run programs the user has permission to run, select the User ID and select the
Authorize Programs button on the Manage Users Page, or select the Authorize Programs button on
the Add/Edit User Page to display the Authorize Programs page.
In addition to the Header Bar and the Footer Bar, the Authorize Programs page contains:
• The User ID appears at the top of the page.
• The list box displays the programs in the system. Programs that the user has permission to run
are highlighted.
• To grant the user permission to run additional programs, select the programs.
• To remove permission for all programs, select Clear All.
• To grant the user permission to run all programs, select Authorize All Programs.
• To grant the user permission to run all programs and all future programs as they are added to
the system, enable Always Authorize All Programs.
• Select the Cancel button to discard your changes and return to the previous page.
• Select the OK button to accept your changes and return to the previous page.
6-54
PN B38322AB
Functional Pages
Rotor Catalog Page
Rotor Catalog Page
Figure 6.58 Rotor Catalog Page
Select the Rotor Catalog button on the Menu Page to display the Rotor Catalog page. Use this page
to examine the detailed specifications for all the rotors compatible with the Avanti JXN series.
In addition to the Header Bar and the Footer Bar, the Rotor Catalog page contains the following
elements:
• The rotor list on the left side of the screen shows compatible rotors. Scroll through this list and
select a rotor to view the detailed information about it.
• The rotor details on the right side of the screen shows details for the selected rotor.
• The Back button returns to the Menu page.
PN B38322AB
6-55
6
Functional Pages
About Page
About Page
Figure 6.59 About Page
The About page appears when you select the About button on the Home Page. This page presents
system information about your instrument.
In addition to the Header Bar and the Footer Bar, the About page contains the following operating
elements:
• The Done button dismisses the page.
• The Print button prints the page.
• The Export button displays the Export Page.
6-56
PN B38322AB
Functional Pages
Zonal Authorization Page
Zonal Authorization Page
IMPORTANT Zonal mode is used when the JCF-Z flow/zonal rotor is installed.
Figure 6.60 Zonal Authorization Page
Select the Zonal Mode button on the side menu of the Home Page, or the Zonal Operation button on
the Menu Page to display the Zonal Authorization page. Enter the authorization code (1793) and
select Authorize to use Zonal mode for the next run.
Figure 6.61 Zonal Mode Button
In addition to the Header Bar and the Footer Bar, the Zonal Authorization page contains the
following elements:
• The Cancel button dismisses the page without entering Zonal mode.
• The Authorize button submits the authorization code and, if correct, displays the Zonal
Operation Page, which replaces the Home Page while you are using Zonal mode.
PN B38322AB
6-57
6
Functional Pages
Zonal Operation Page
Zonal Operation Page
Figure 6.62 Zonal Operation Page
Enter the correct authorization code from the Zonal Authorization Page to display the Zonal
Operation page and enter Zonal mode.
When you use Zonal mode, the Zonal Operation page replaces the Home Page until Zonal mode ends.
In addition to the Header Bar and the Footer Bar, the Zonal Operation page contains the following
elements:
• As a display, the Status Display/Buttons show the current step in the Zonal or Continuous Flow
run procedure. Once a run has started, the Loading, Running, and Unloading buttons become
active and are used to move between Zonal process steps. See Zonal and Continuous Flow
Operation in CHAPTER 3, Operations for additional details.
• As a display, the Load Speed Display/Button shows the sample loading speed. Use the arrow
buttons above and below to increase or decrease the sample loading speed, or select the button
to enter the sample loading speed using the keypad.
• As a display, the Run Speed Display/Button shows the sample running speed. Use the arrow
buttons above and below to increase or decrease the sample running speed, or select the button
to enter the sample running speed using the keypad.
• As a display, the Unload Speed Display/Button shows the sample unloading speed. Use the
arrow buttons above and below to increase or decrease the sample unloading speed, or select
the button to enter the sample unloading speed using the keypad.
• The Slow to Zero RPM button is for preliminary steps which require bringing the rotor to a stop
temporarily during the initial loading adjustments. The button brings the rotor to a stop
without exiting Zonal mode.
6-58
PN B38322AB
Functional Pages
Zonal Operation Page
• As a display, the Rotor Display/Button shows the current selected rotor. Select the button to
display the Select Rotor page.
NOTE Only rotors available for use with the Zonal mode will show in the list.
• As a display, the Accel and Decel Display/Button shows the currently selected acceleration or
deceleration profile. Select the button to display the Set Acceleration/Deceleration Profiles
Page.
• The Cancel button ends Zonal mode before loading is complete, and returns to the Home page.
Cancel is available only until you start the run or select Slow to Zero RPM. When the run is in
progress, use Stop to end the run and exit Zonal mode.
Use the Footer Bar for setting the run speed, time, and temperature.
PN B38322AB
6-59
6
Functional Pages
Zonal Operation Page
6-60
PN B38322AB
CHAPTER 7
Maintenance and Troubleshooting
Overview
This chapter contains care and maintenance procedures to be performed regularly.
This chapter contains information about:
• Field Service
• Maintenance
• Decontamination
• Sterilization and Disinfection
• Replacing the Air Filter
• Checking the Vacuum Pump
• Diagnostics/User Messages
• Accessing the Rotor in Case of Power Failure
• JCF-Z Rotor Identification
• Storage and Transportation
• Supply List
Field Service
For any maintenance not covered in this manual, contact your Beckman Coulter Representative for
assistance. USA customers can call 1-800-742-2345. For international contacts, see the website at
www.beckmancoulter.com or use the contact numbers on the inside front cover of this book.
NOTE It is your responsibility to decontaminate the instrument, as well as any rotors and accessories, before
requesting service by your Beckman Coulter Representative.
Maintenance
Perform the following procedures regularly to ensure continued performance and long service life
of the centrifuge.
PN B38322AB
7-1
Maintenance and Troubleshooting
Maintenance
Performing Instrument Maintenance
1
Inspect the centrifuge chamber for accumulations of sample, dust, or glass particles from
broken sample tubes.
a. Clean as required (see Cleaning below).
2
Check the air filter on the back panel for obstructions.
a. Keep vents clear and clean.
3
4
Wipe condensation out of the chamber between runs with a sponge or clean cloth to prevent
chamber icing.
If chamber icing occurs, defrost the system and wipe moisture out of the chamber before use.
a. To defrost the system, install a rotor, set the temperature to 30°C, and start a run for 20
minutes.
(These are suggested settings that may be adjusted as appropriate for your laboratory
conditions.)
b. Make sure that the chamber, chamber gasket, and door are dry before each run.
NOTE Before using any cleaning or decontamination methods except those recommended by the
manufacturer, users should check with the manufacturer that the proposed method will not damage
the equipment.
Cleaning
Cleaning the Instrument
1
Clean the centrifuge frequently.
a. Always clean up spills when they occur to prevent corrosives or contaminants from drying
on component surfaces.
2
To prevent accumulations of sample, dust, and/or glass particles from broken sample tubes,
keep the chamber clean and dry by frequent wiping with a cloth or paper towel.
a. For thorough cleaning, wash the chamber using a mild detergent such as Solution 555.
b. Dilute the detergent with water (10 parts water to 1 part detergent).
c. Rinse thoroughly and dry completely.
7-2
PN B38322AB
Maintenance and Troubleshooting
Decontamination
3
Clean the centrifuge exterior surfaces by wiping with a cloth dampened with Solution 555.
Dilute the detergent with water (10 parts water to 1 part detergent).
Do not use acetone.
4
Clean the drive hub regularly using Solution 555 and a soft brush.
a. Dilute the detergent with water (10 parts water to 1 part detergent).
b. Rinse thoroughly and dry completely.
Tube Breakage
1
If a glass tube breaks, and all the glass is not contained in the bucket or rotor, be sure to
thoroughly clean the chamber.
WARNING
Risk of possible biohazardous contamination and/or operator injury. Be careful
when examining or cleaning the chamber and chamber gasket, as sharp glass
fragments may be embedded in their surfaces.
2
Examine the chamber gasket to make sure that no glass particles are retained in it.
a. Carefully remove any glass particles that may remain.
3
Carefully wipe away any glass particles that remain in the chamber.
Decontamination
If the instrument and/or accessories are contaminated with radioactive or pathogenic solutions,
follow appropriate decontamination procedures as determined by your laboratory safety officer.
Refer to Chemical Resistances (publication IN-175), or contact your Beckman Coulter
Representative to ensure that the decontamination method does not damage any part of the
instrument (or accessories).
PN B38322AB
7-3
7
Maintenance and Troubleshooting
Sterilization and Disinfection
Sterilization and Disinfection
WARNING
While Beckman Coulter has tested these methods and found that they do not
damage the instrument, no guarantee of sterility or disinfection is expressed or
implied. When sterilization or disinfection is a concern, consult your laboratory
safety officer regarding proper methods.
WARNING
Ethanol is a volatile liquid that cannot be used on or near an operating instrument
due to fire hazard.
CAUTION
Ethanol is a flammability hazard. Do not use it in or near operating centrifuges.
Ethanol (70%) may be used to clean any exterior surface of the centrifuge. While Beckman Coulter
has tested ethanol (70%) and found that it does not damage the centrifuge, no guarantee of sterility
or disinfection is expressed or implied. When sterilization or disinfection is a concern, consult your
laboratory safety officer regarding proper methods to use.
Replacing the Air Filter
1
Check the air filter regularly and replace it about once a year, or more often if it looks dirty.
The air filter is not fastened to the centrifuge, so no tools are required for removal or
installation.
1.
2.
3.
4.
Frame Edge
Air Filter
Retaining Strip
Frame Edge
1
2
4
3
7-4
PN B38322AB
Maintenance and Troubleshooting
Checking the Vacuum Pump
2
To remove the air filter, hold the side edges and lift the filter straight up until the bottom edge
is above the centrifuge bottom retaining strip.
a. Pull the filter out, bottom edge first, and discard it.
3
Install a new filter.
a. The filter has a directional arrow on one of its edges; install the filter with this arrow
pointing toward the centrifuge.
b. Holding the filter by the side edges, insert the top half behind the frame edge and lift up
until the bottom half clears the retaining strip.
c. Then, set the bottom edge down.
Checking the Vacuum Pump
IMPORTANT An oil level check is only applicable to the Avanti JXN-30 instrument.
Check the vacuum pump oil level at approximately every 1000 cycles. To access the vacuum pump,
you must remove the centrifuge front panel. The pump is on the bottom lower left of the centrifuge
housing, with the view shown in Figure 7.1 facing out.
Figure 7.1 Front View of Vacuum Pump
1
4
3
2
1. Filter Cap
2. Drain Plug
PN B38322AB
3. Minimum Fill Line
4. Maximum Fill Line
7-5
7
Maintenance and Troubleshooting
Diagnostics/User Messages
1
Remove the centrifuge front panel.
See Accessing the Rotor in Case of Power Failure for instructions.
2
Unscrew the filler cap. Set the cap aside.
3
Add oil (PN 392760) up to the maximum fill line. Pour the oil through a funnel if necessary.
4
Screw the filler cap back on tightly.
5
Replace the front panel. See Replacing the Front Panel on the Centrifuge for instructions.
Diagnostics/User Messages
When a condition arises that requires operator attention, the header bar turns yellow or red. A page
displays the diagnostic message. User messages communicate information about the centrifuge or
alert you to an abnormal condition. For a list of the possible malfunctions and their corrective
actions, see APPENDIX C, Diagnostics.
Accessing the Rotor in Case of Power Failure
WARNING
Any maintenance procedure requiring removal of a panel exposes the operator to
the possibility of electrical shock and/or mechanical injury. Therefore, turn the
power off (O) and disconnect the instrument from the main power source by
removing the Mains (power) plug from the outlet receptacle, and refer such
maintenance to qualified service personnel.
WARNING
Before performing this procedure, verify that the rotor is not spinning by listening
carefully for any noise coming from the chamber. Proceed only if the instrument
is quiet. Never attempt to override the door interlock system while the rotor is
spinning.
If the facility power fails only momentarily, the centrifuge will resume operation when the power
is restored and the rotor will return to the set speed. In the event of an extended power failure,
7-6
PN B38322AB
Maintenance and Troubleshooting
Accessing the Rotor in Case of Power Failure
you may need to override the door-locking mechanism manually to remove the rotor and retrieve
your sample.
To access the door-locking mechanism, you must remove the instrument front panel. Two latches
secure the front panel in place; these latches are accessible through two holes at the upper right
and left of the panel (see Figure 7.2).
Figure 7.2 Emergency Door Release Latch Access
1
Turn the power switch to off (O) and unplug the power cord from the main source by removing
the Mains (power) plug from the outlet receptacle.
• The Mains (power) plug is the disconnect device and must remain easily accessible.
— Position the centrifuge so that it is easy to remove the Mains (power) plug from the
outlet receptacle.
2
3
Insert a 4-mm or 5/32-in. Allen wrench straight through one of the holes (either one) and turn
the wrench to the left (counterclockwise) until the latch disengages.
Repeat step 2, inserting the Allen wrench through the other hole.
• After the second latch disengages, the front panel will fall forward about an inch from
the top.
• The bottom of the front panel is held in place by three grooved brackets, attached to the
front panel, that seat over a metal retaining strip on the centrifuge bottom panel.
PN B38322AB
7-7
7
Maintenance and Troubleshooting
Accessing the Rotor in Case of Power Failure
4
Lift the front panel up and off the centrifuge; set it aside.
• You will see an inner front panel that extends about halfway down from the centrifuge top
(see Figure 7.3).
• Below this inner panel is a black manual door release interlock lever (see Figure 7.3).
Figure 7.3 Manual Door Release
1. Inner Front Panel
2. Retaining Strip
5
3. Manual Door Release
Interlock Lever
Pull the interlock lever out and to the left (at about a 45-degree angle), and while holding it out,
step on the foot pedal.
Depending on the level of vacuum in the chamber at the time of the power failure, the door may
or may not open.
a. If it opens, go to step 6.
b. If it does not open, you will need to manually vent the vacuum. Go to step 7.
6
After the door opens, first release the foot pedal and then release the interlock lever.
Sample can be removed.
a. Go to step 10.
7
To vent the chamber vacuum, grasp the rubber hose and pull it up until it comes off of the pump
fitting (see Figure 7.4).
Use a back-and-forth motion as you pull; this takes quite a bit of force.
7-8
PN B38322AB
Maintenance and Troubleshooting
Accessing the Rotor in Case of Power Failure
The vacuum will be completely vented several seconds after the hose is detached.
NOTE Several tubing lines are tied to the red hose. As you grasp the hose, place your hand over these
lines. Make sure that they stay connected as you pull.
CAUTION
Risk of instrument damage. Do not twist the hose to the left (counterclockwise) as
you pull the hose, or you will unscrew the hose fitting.
Figure 7.4 Venting the Chamber Vacuum - Removing the Red Hose
2
3
1
1. Vacuum Pump
2. Red Hose
8
3. Pump Fitting
Replace the hose by pushing it down over the fitting as far as it can go (see Figure 7.5).
Figure 7.5 Venting the Chamber Vacuum - Replacing the Red Hose
1
PN B38322AB
7-9
7
Maintenance and Troubleshooting
Accessing the Rotor in Case of Power Failure
1. Red Hose
9
Pull the interlock level out and left, and while holding it out, step on the foot pedal.
DANGER
Risk of serious injury or death to the operator. Never try to slow or stop the rotor
by hand. Always wait for the rotor to come to a complete stop before attempting
to access the sample.
10 Remove your sample.
Replacing the Front Panel on the Centrifuge
1
Holding the panel at the top (with the instrument label facing out), insert the three grooved
brackets on the bottom inside of the door over the front panel retaining strip (see Figure 7.6).
a. Push the top of the front panel into place.
Figure 7.6 Front Panel Retaining Strip
1
1. Retaining Strip
2
Hold the left top edge in place and insert the Allen wrench through the hole.
a. Turn to the right (clockwise) until the latch engages.
7-10
PN B38322AB
Maintenance and Troubleshooting
JCF-Z Rotor Identification
3
Repeat step 2 on the right side
The second latch engages.
JCF-Z Rotor Identification
The rotor identification system can, under two specific conditions, misidentify the JCF-Z
continuous flow/zonal rotor. If the rotor is misidentified, the the run will be stopped. Follow the
steps below to resolve the issue.
NOTE Misidentification can be prevented by returning your JCF-Z rotor to the Beckman Coulter factory to
have magnets added to the rotor body. The magnets ensure correct identification. Call your local
Beckman Coulter Representative* for more information.
JCF-Z rotors manufactured after March, 1997, have factory-installed magnets.
1
On the first few uses of a new JCF-Z rotor, or in an older JCF-Z rotor with newly replaced bearings, run
the rotor from 0 to 5000 RPM and back to 0 RPM three times.
This procedure will distribute lubricant around the bearings in the rotating seal assembly,
reducing drag.
2
In older JCF-Z rotors with bearings that have not been replaced recently, follow the same procedure
as for a new JCF-Z rotor (perform three runs from 0 to 5000 RPM and back to 0 RPM) to ensure
that the bearings are properly lubricated.
If misidentification recurs after the third run, when the bearings are lubricated, this indicates
that the bearings are worn and need to be replaced.
a.
Replace the bearings following the instructions in the JCF-Z manual (JCFZ-IM).
NOTE If the JCF-Z rotor is misidentified, the run will be stopped.
Storage and Transportation
To ensure that the instrument does not get damaged, contact your Beckman Coulter Representative
for specific instructions and/or assistance in preparing the equipment for transport or long-term
storage.
* In the United States, call 1-800-742-2345. Outside the U.S., contact your local Beckman Coulter office or visit us at
www.beckmancoulter.com.
PN B38322AB
7-11
7
Maintenance and Troubleshooting
Supply List
Supply List
Contact Beckman Coulter Sales for assistance ordering parts and supplies. Customers in the United
States call 1-800-742-2345. For international contacts, see the website at www.beckmancoulter.com
or use the contact numbers on the inside front cover of this book. A partial list of supplies is given
below for your convenience. See the Beckman Coulter High Performance Rotors, Tubes & Accessories
catalog (BR-8102, available at www.beckmancoulter.com) for detailed information on ordering
rotors, tubes, and accessories.
Replacement Parts and Supplies
Table 7.1 Replacement Parts
Description
Part Number
Air filter
885218
Solution 555 (1 qt)
339555
Avanti JXN-30 Zonal Bracket Kit for Cole-Parameter size 16 tubing
(6.4-mm [1/4-in.] O.D.)
363843
Zonal Bracket (qty 1)
363818
Thumbscrew, stainless steel, M4 (threads) X 19 mm (qty 2)
893412
Thumbscrew, stainless steel, M4 (threads) X 12 mm (qty 2)
893411
Cable Clamp, nylon, 6.4-mm (1/4-in.) I.D. (qty 10)
000499
Avanti JXN-26 Zonal Bracket Kit for Cole-Parameter size 16 tubing
(6.4-mm [1/4-in.] O.D.)
366431
Zonal Bracket (qty 1)
366430
Thumbscrew, stainless steel, M4 (threads) X 19 mm (qty 2)
893412
Thumbscrew, stainless steel, M4 (threads) X 12 mm (qty 2)
893411
Cable Clamp, nylon, 6.4-mm (1/4-in.) I.D. (qty 10)
000499
Zonal Tubing Adapter for Cole-Parmer size 14 tubing
(4.8-mm [3/16-in.] (O.D.)
363844
NOTE Kit 366431 for the Avanti JXN-26 or kit 363843 for the Avanti
JXN-30 is also required.
Tubing Adapter, stainless steel, for size 14 tubing (qty 2)
363830
Cable Clamp, nylon, 4.8-mm (3/16-in.) I.D. (qty 10)
003343
Zonal Tubing Adapter for Cole-Parmer size 15 tubing
(9.6-mm [3/16-in.] (O.D.)
363845
NOTE Kit 366431 for the Avanti JXN-26 or kit 363843 for the Avanti
JXN-30 is also required.
Tubing Adapter, stainless steel, for size 15 tubing (qty 2)
7-12
363831
PN B38322AB
Maintenance and Troubleshooting
Supply List
Table 7.1 Replacement Parts
Description
Cable Clamp, nylon, 9.6-mm (3/8-in.) I.D. (qty 10)
External HEPA Filter Assembly
Part Number
000596
B45269
NOTE Accessory HEPA filter Kit B37916 is required.
PN B38322AB
7-13
7
Maintenance and Troubleshooting
Supply List
7-14
PN B38322AB
APPENDIX A
Preinstallation Requirements
Preinstallation Requirements
Do not attempt to install this instrument. Its purchase price includes installation by Beckman Coulter
personnel. Installation by anyone other than an authorized Beckman Coulter Representative invalidates
any warranty covering the instrument.
Preinstallation requirements have been sent prior to shipment of the instrument. The following
information is provided in case the centrifuge must be relocated.
The centrifuge will be installed upon initial purchase by your Beckman Coulter Representative after
preinstallation requirements for power and site preparation have been met. The following
equipment is required for preinstallation:
• Voltmeter
• For single phase centrifuges: two 30-ampere circuit breakers
• For three phase centrifuges: three 16-ampere circuit breakers
• Power receptacle (see Figure A.1 or Figure A.2)
Electrical Requirements
Power to the centrifuge should originate directly from a main power line transformer at a power
source known to be clear of erratic loads, spikes, and electromagnetic interference. Make sure that
there are properly rated thermal circuit breakers at the service panel to protect the centrifuge
circuit. If fuses must be used instead of the specified circuit breakers, the fuses may require a rating
of greater than 30 amperes (for single-phase centrifuges) or greater than 16 amperes (for
three-phase centrifuges).
Terminate the open end of the harmonized cord with a certified single- or three-phase connector
suitable for the power supplied in the country of intended use (see Table A.1). Install only one
centrifuge per circuit.
PN B38322AB
A-1
Preinstallation Requirements
Preinstallation Requirements
Table A.1 Nominal Supply Voltage Ratings for the Avanti JXN Series
Nominal
Instrument
Voltage Rating
Nominal Supply
Frequency
Power Cord and Plug Description
Single-phase,
200/208/240 V
180–264 V,
50/60 Hz, 30 A
permanently attached three-wire
UL/CSA-approved cord with NEMA
type 6-30P plug
Single-phase,
230 V
180–264 V,
50 Hz, 30 A
permanently attached three-wire
CENELEC harmonized cord without
plug
Three-phase,
220/380 V +
Neutrala
313–457 V,
plus neutral,
50 Hz, 16 A
permanently attached five-wire
CENELEC harmonized cord without
plug
a. Unbalanced three-phase. Split for single-phase operation internally.
To ensure optimal safety, the centrifuge should be wired to a remote emergency switch (preferably
outside the room where the centrifuge is housed, or adjacent to the exit from that room). In case of
a malfunction, the centrifuge can be disconnected from the main power source by removing the
Mains (power) plug from the outlet receptacle.
WARNING
To reduce the risk of electrical shock, this equipment uses a three-wire or five-wire
electrical cord and plug to connect the centrifuge to earth-ground. To preserve
this safety feature, make sure that the matching wall outlet receptacle is properly
wired and earth-grounded.
Prior to instrument purchase, the power configuration should be determined and the appropriate
instrument ordered.
Single and Three-Phase Power Connections
Figure A.1 shows the power connection for single-phase centrifuges, including earth-ground and
two power leads with 30-ampere circuit breakers. Figure A.2 shows the power connection for
three-phase centrifuges, including earth-ground and three power leads with minimum 16-ampere
circuit breakers and common neutral connection. Table A.2 contains wiring information.
A-2
PN B38322AB
Preinstallation Requirements
Preinstallation Requirements
Figure A.1 Single-Phase Electrical Requirements
1
2
4
3
1
1. 30-ampere Circuit Breaker
2. Wall Outlet: Hubell 9930,
Bryant 96-30-FR, or Equivalent
(NEMA 6-30 R)
3. Earth-Ground
4. Measured Line Voltage
Figure A.2 Three-Phase “Y” Electrical Requirements
1
2
3
1
1
4
1. 16-ampere Circuit Breaker
2. Neutral
3. Measured Line Voltage Phase to Phase
4. Earth-Ground
Table A.2 Required Wire Connections
Wire Insulation Color
Green/Yellow
Light Blue
Brown
Black (three-phase
connections only)
PN B38322AB
Terminal
Symbol
Harmonized
North American
Neutral
N
L
Live or Line
L
L
Live or Line (qty 2)
L
—
Earth ground
A-3
A
Preinstallation Requirements
Preinstallation Requirements
Additional Requirements for Three-Phase Power Connections
For three-phase power service to the centrifuge, use the “Y” connected configuration shown in
Figure A.3. Also note the following information:
• The steady state current draw of the centrifuge can be as high as 12 amperes per phase,
depending on the voltage.
• Inrush current to the centrifuge is 100 amperes for up to 2 seconds during the refrigeration
start period. Circuit breakers, whether thermal or magnetic actuating, must be a “motor start”
delay type.
• The centrifuge can tolerate a drop of 15 volts during the start period at low line voltage (see
Figure A.3 for the acceptable voltage ranges). The mains power for the centrifuge must be of
sufficient wire gauge to provide this condition. The wire gauge required at a particular site
must be determined by a facilities engineer at that site.
Figure A.3 Correct and Incorrect Three-Phase Power Configurations
1
2
3
312–456
180–264
1. Correct Configuration “Y”
2. Incorrect Configuration “Delta”
4
3. Safety Ground
4. Circuit Common (Neutral)
Space and Location Requirements
1
Locate the instrument on a clean, level floor.
• The Mains (power) plug is the disconnect device and must remain easily accessible.
• Position the centrifuge so that it is easy to remove the Mains (power) plug from the outlet
receptacle.
2
Select a location away from heat-producing laboratory equipment.
If ambient temperature exceeds 38°C (100°F), premature component failure may result.
3
A-4
In addition to space for the centrifuge, allow a 7.7-cm (3-in.) clearance on each side of the
centrifuge and a 16-cm (6.25-in.) clearance behind the centrifuge for air circulation.
PN B38322AB
Preinstallation Requirements
Using J2 Series Rotors in the Avanti JXN Series
The centrifuge must have adequate air ventilation to ensure compliance to local requirements
for vapors produced during centrifuge operation.
WARNING
Do not place the centrifuge near areas containing flammable reagents or
combustible fluids. Vapors from these materials could enter the instrument’s
air system and be ignited.
Using J2 Series Rotors in the Avanti JXN Series
CAUTION
Do not use the Beckman Coulter JA-10, JS-7.5, or JA-14 rotors in the Avanti JXN
centrifuge before reading this information.
Checking for Rotor Drive Pins
Rotors used in the Avanti JXN series centrifuges must have drive pins in the rotor drive hole (see
Figure A.4). These drive pins engage with the centrifuge spindle hub to ensure that the rotor does
not slip during acceleration. Some Beckman Coulter rotors, including the JA-10, the JS-7.5, and the
JA-14, have been manufactured without drive pins because pins were not needed when these rotors
were used in J2 series centrifuges.
PN B38322AB
A-5
A
Preinstallation Requirements
Using J2 Series Rotors in the Avanti JXN Series
B
Figure A.4 Checking the Rotor for Drive Pins
EC
KMA N
3
4
KM
EC A
N
B
5
1
1. Top View
2. Side View
3. Rotor Drive Hole
2
4. Drive Pins
(Angled pins shown; pins can also be vertical or horizontal.)
5. Drive Spindle Assembly
The rotor pins are positioned parallel to the Beckman name engraved at the center of the rotor body
(see Figure A.4). Knowing the pin orientation before you install the rotor will help to ensure that
you position the rotor properly on the hub, minimizing the chance of hub damage.
Check all J2 series rotors for drive pins before using them in an Avanti JXN series centrifuge and do not use
rotors without drive pins in the Avanti JXN series. To check for drive pins, hold the rotor up or turn it
on its side and look into the drive hole. If you do not see two metal pins in the hole, do not use the
rotor in the Avanti JXN series. Call your local Beckman Coulter office* for information on returning
the rotor to the factory for upgrading.
* In the United States, call 1-800-742-2345. Outside the U.S., contact your local Beckman Coulter office or visit us at
www.beckmancoulter.com.
A-6
PN B38322AB
Preinstallation Requirements
Using J2 Series Rotors in the Avanti JXN Series
Using the JCF-Z Continuous Flow/Zonal Rotor
Zonal Bracket Kits
A special bracket and mounting hardware are required when the JCF-Z Continuous Flow/Zonal
Rotor is used. These parts are contained in the Zonal Bracket Kit. The Zonal Bracket Kit includes a
bracket, mounting hardware, and assembly instructions. This kit is for use with Cole-Parmer tubing
size 16 (6.4 mm [1/4-in.] O.D.), the tubing size most commonly used with the JCF-Z rotor.
Two additional kits are available, one which contains adapters for size 14 tubing (4.8 mm [3/16-in.]
O.D.) and one which contains adapters for size 15 tubing (9.6 mm [3/8-in.] O.D.). If you wish to
use either of these sizes of tubing, you will need to purchase one of these kits in addition to the
basic kit.
See Table 7.1 in CHAPTER 7, Maintenance and Troubleshooting for a complete list of Zonal Bracket
Kit contents.
PN B38322AB
A-7
A
Preinstallation Requirements
Using J2 Series Rotors in the Avanti JXN Series
A-8
PN B38322AB
APPENDIX B
Temperature Calibration Procedure
Introduction
The Avanti JXN series centrifuge specification for temperature control is ± 2°C. The following
procedure is provided for those cases in which temperature control within ± 1°C is required.
In this procedure, you will measure the temperature of your sample after equilibrating the rotor
temperature for a minimum of 1 hour. Based on the test results, you can then adjust the centrifuge
temperature setting to bring your sample as close as possible to the required temperature.
Calibrating Temperature
1
For runs at other than ambient temperature, precool or prewarm the rotor and test samples
to the required temperature.
The length of precooling/prewarming time depends on how different the rotor starting
temperature is from the required run temperature.
2
3
Install the rotor with adapters, if applicable, and tubes or bottles filled with sample buffer or
water (if above 2°C).
Set the speed to 2000 RPM, the time to HOLD, and the temperature to the required run
temperature.
a. Start the run.
4
After 30 minutes, set the required run speed, and allow the system to run for at least 1 hour.
NOTE The system must run for at least 1 hour before the temperature of the buffer or water is
measured. The length of time required for equilibration depends on the rotor and centrifuge starting
temperatures and the ambient room temperature.
5
PN B38322AB
After at least 1 hour, measure the temperature of the buffer or water using a thermometer or
thermocouple.
B-1
Temperature Calibration Procedure
Introduction
6
If the measured and set temperatures are different, note how many degrees different they are
and adjust the set temperature up or down that number of degrees.
For example:
B-2
If the required sample
temperature is
And the measured buffer/
water temperature is
Set the temperature
to
4°C
6°C
2°C
5°C
4°C
6°C
PN B38322AB
APPENDIX C
Diagnostics
Overview
This section lists possible malfunctions and corrective actions. Maintenance procedures are
described in CHAPTER 7, Maintenance and Troubleshooting.
For any maintenance not covered in this manual, contact your Beckman Coulter Representative for
assistance. USA customers can call 1-800-742-2345. For international contacts, see the website at
www.beckmancoulter.com or use the contact numbers on the inside front cover of this book.
NOTE It is your responsibility to decontaminate the centrifuge, as well as any rotors and/or accessories,
before requesting service by your Beckman Coulter Representative.
Diagnostics/User Messages Chart
Refer to the chart below for a list of possible malfunctions and their corrective actions.
Table C.1 Diagnostics/User Messages Chart
Message
S1-S4/
Definition/Result
Recommended Action
Run coasts to a stop
Contact your Beckman Coulter Representative.
Contact your Beckman Coulter Representative.
Internal firmware error
Run stops using maximum
brake
S9-10, S14/
Run coasts to a stop
Contact your Beckman Coulter Representative.
Run stops using maximum
brake
Attempt to clear error. If problem persists,
contact your Beckman Coulter Representative.
Connection to external
devices lost
Make sure external devices are powered on.
Internal firmware error
S7
Communications error
P5, S15/
Communications error
S108/
Network
communications error
PN B38322AB
C-1
Diagnostics
Diagnostics/User Messages Chart
Table C.1 Diagnostics/User Messages Chart (Continued)
Message
S109-S110
Definition/Result
Network connection lost
Network
communications error
S111/
USB port error
S113/
Touchscreen not
detected
S117/
Notification only
If problem persists, contact your Beckman
Coulter Representative.
Data will not save to or
import from USB device
USB device may be full or removed too quickly.
Save again using a different USB device.
Run stops using maximum
brake
If problem persists, contact your Beckman
Coulter Representative.
Data will not print
Make sure printer is powered on and necessary
drivers are installed. If problem persists, contact
your Beckman Coulter Representative.
Notification only
Contact your Beckman Coulter Representative.
Hard drive is 90% full
Backup files soon.
Printer error
S123/
Make sure ethernet cable is plugged in.
Make sure network is active.
System data error
S112/
Recommended Action
Communications error
S124/
Hard drive space low
S127/
Internal software error
S128/
Door lockout active
P3, P200/
AC power loss
P4, P201/
AC power loss
L2/
Door latch error
L3/
Door latch error
L4/
Door latch error
C-2
Contact your Beckman Coulter Representative.
Calibration parameters
lost
Contact your Beckman Coulter Representative.
Unable to open door until
lockout time expires
Wait until door lockout timer expires before
attempting to open the door.
Notification only, continue
run
Clear error
Run stops using selected
deceleration profile
Clear error
Run stops using maximum
brake
Close door firmly. Clean latch areas with a dry
lintless cloth. If error persists, contact your
Beckman Coulter Representative.
Run stops using maximum
brake
Clear error and attempt to restart the run. If error
persists, contact your Beckman Coulter
Representative.
Run stops using maximum
brake
Restart the centrifuge and perform a brief run. If
door will still not open after decel, contact your
Beckman Coulter Representative.
PN B38322AB
Diagnostics
Diagnostics/User Messages Chart
Table C.1 Diagnostics/User Messages Chart (Continued)
Message
L5-L7/
Definition/Result
Recommended Action
Run stops using maximum
brake
Do not open the door and power instrument
down. Contact your Beckman Coulter
Representative.
Run stops using maximum
brake
Clear error, power instrument down and then
back up. If error persists, contact your Beckman
Coulter Representative.
Run stops using maximum
brake
Turn lights out above instrument, clear error, and
attempt to make the run again. If error persists,
contact your Beckman Coulter Representative.
Run stops using maximum
brake
Remove samples and insure rotor is balanced
and tied down properly. Restart run. If imbalance
continues, contact your Beckman Coulter
Representative.
Run stops using maximum
brake
Make sure the rotor is installed and compatible
with the centrifuge. If error persists, contact your
Beckman Coulter Representative.
Rotor mismatch
Run stops using maximum
brake
Insure rotor installed matches rotor entered on
user interface. If error persists, contact your
Beckman Coulter Representative.
D1-D15/
Run coasts to a stop
Contact your Beckman Coulter Representative.
Before trying to open the door, listen carefully
and make sure that no sound is coming from the
chamber (indicating a spinning rotor).
Run coasts to a stop
Contact your Beckman Coulter Representative.
Notification only, continue
run
Press STOP, then clear the error Set the new run
speed and then press START to begin a new run.
If error persists, contact your Beckman Coulter
Representative.
Contact your Beckman Coulter Representative.
Rotor acceleration error
Notification only, continue
run
H7/
Run coasts to a stop
Contact your Beckman Coulter Representative.
Run stops using maximum
brake
Contact your Beckman Coulter Representative.
Door latch error
L8-L10/
Door latch error
L11-L12/
Door latch error
I1/
Imbalance error
R1, R4/
Rotor not recognized or
no rotor
R3/
Drive error
H1-H3/
Speed control error
H4/
Rotor acceleration error
H5-H6/
Communications error
T1-T2/
Temperature control
error
PN B38322AB
C-3
C
Diagnostics
Diagnostics/User Messages Chart
Table C.1 Diagnostics/User Messages Chart (Continued)
Message
T300/
Set temperature error
C1, C4/
Temperature control
error
C2-C3, C5/
Temperature control
error
F1, F3-F11/
Vacuum error
F2/
Vacuum error
C-4
Definition/Result
Recommended Action
Set Temperature
automatically adjusted
Clear error
Notification only, continue
run
If error persists, contact your Beckman Coulter
Representative.
Run stops using maximum
brake
Contact your Beckman Coulter Representative.
Run stops using maximum
brake
Contact your Beckman Coulter Representative.
Notification only, continue
run
If error persists, contact your Beckman Coulter
Representative.
PN B38322AB
APPENDIX D
Third Party Contributions and Legal Notices
Contributions and Legal Notices
Software accompanying this centrifuge contains Beckman Coulter Inc.’s works (“Beckman Works”)
and modified or unmodified binary form of third party contributions (“Third Party Works”). Rights
to only the Third Party Works are offered or granted to downstream software recipients and
developers, under their respective licenses, as provided below. The licenses provided below do not
apply to any portion of Beckman Works. All intellectual property rights in and to Beckman Works
(including but not limited to copyright in and to Beckman Works, any derivative work based on part
or all of Beckman Works, and images, photographs, text, and other information that may be
incorporated in Beckman Works), are owned and reserved by Beckman Coulter, Inc.
A. AdornedControl, available at <http://www.codeproject.com/KB/WPF/adornedcontrol.aspx>, by
Ashley Davis, the standard version included in its binary form linked with other modules. This work
is made available under the Code Project Open License 1.02 (“CPOL”), available at
<http://www.codeproject.com/info/cpol10.aspx>. By exercising any rights to AdornedControl, the
recipient accepts and agrees to be bound by the terms of CPOL.
B. PasswordAssistant, available at <http://blog.functionalfun.net/2008/06/wpf-passwordbox-anddata-binding.html>. and ListBoxSelectedItemsBinding, available at <http://blog.functionalfun.net/
2009/02/how-to-databind-to-selecteditems.html>, both by Samuel Jack. These works are made
available under the Creative Commons Attribution 2.0 England and Wales License, available at
<http://creativecommons.org/licenses/by/2.0/uk/>.
C. BalancedWrapPanel, ©Copyright Microsoft Corporation, available at <http://blogs.msdn.com/
b/delay/archive/2009/12/13/wrap-music-a-more-flexible-balanced-wrappanel-implementationfor -silverlight-and-wpf.aspx>, by David Anson; MvvmFoundation.WPF, available at <http://
mvvmfoundation.codeplex.com/SourceControl/list/changesets#>, by Josh Smith; and modified
portions of MvvnFoundation.WPF, contained in MvvmFoundatiopn.MH-Changes.zip, available at
<http://mvvmfoundation.codeplex.com/workitem/5453>, by Matt Heffron. These works are made
available under the following license:
Microsoft Public License (Ms-PL)
This license governs use of the accompanying software. If you use the software, you accept this
license. If you do not accept the license, do not use the software.
1. Definitions
The terms “reproduce,” “reproductions,” “derivative works,” and “distribution” have the same
meaning here as under U.S. copyright law.
PN B38322AB
D-1
Third Party Contributions and Legal Notices
Contributions and Legal Notices
A “contribution” is the original software, or any additions or changes to the software.
A “contributor” is any person that distributes its contribution under this license.
“Licensed patents” are a contributor’s patent claims that read directly on its contribution.
2. Grant of Rights
a. Copyright Grant--Subject to the terms of this license, including the license conditions and
limitations in section 3, each contributor grants you a non-exclusive, worldwide, royaltyfree copyright license to reproduce its contribution, prepare derivative works of its
contribution, and distribute its contribution or any derivative works that you create.
b. Patent Grant--Subject to the terms of this license, including the license conditions and
limitations on patents to make, have made, use, sell, offer for sale, import, and/or
otherwise dispose of its contribution in the software or derivative works of the
contribution in the software.
3. Conditions and Limitations
a. No Trademark License--This license does not grant you rights to use any contributors’
name, logo, or trademarks.
b. If you bring a patent claim against any contributor over patents that you claim are
infringed by the software, your patent license from such contributor to the software ends
automatically.
c. If you distribute any portion of the software, you must retain all copyright, patent,
trademark, and attribution notices that are present in the software.
d. If you distribute any portion of the software in source code form, you may do so only under
this license by including a complete copy of this license with your distribution. If you
distribute any portion of the software in compiled or object code form, you may only do so
under a license that complies with this license.
e. The software is licensed “as-is”. You bear the risk of using it. The contributors give no
express warranties, guarantees, or conditions. You may have additional consumer rights
under your local laws which this license cannot change. To the extent permitted under
your local laws, the contributors exclude the implied warranties of merchantability,
fitness for a particular purpose and non-infringement.
D. VNC® Free Edition 4.1.3, Copyright 2002-2008 RealVNC Limited, is included in its unmodified
binary form as aggregate work. A copy of this work in source form may be obtained at no cost by
contacting Beckman Coulter Technical Support. This work is made available under the following
license:
GNU GENERAL PUBLIC LICENSE
Version 3, 29 June 2007
Copyright 2007 Free Software Foundation, Inc. <http://fsf.org/>
Everyone is permitted to copy and distribute verbatim copies of this license document, but
changing it is not allowed.
Preamble
The GNU General Public License is a free, copyleft license for software and other kinds of works.
The licenses for most software and other practical works are designed to take away your freedom
to share and change the works. By contrast, the GNU General Public License is intended to
D-2
PN B38322AB
Third Party Contributions and Legal Notices
Contributions and Legal Notices
guarantee your freedom to share and change all versions of a program--to make sure it remains free
software for all its users. We, the Free Software Foundation, use the GNU General Public License for
most of our software; it applies also to any other work released this way by its authors. You can
apply it to your programs, too.
When we speak of free software, we are referring to freedom, not price. Our General Public Licenses
are designed to make sure that you have the freedom to distribute copies of free software (and
charge for them if you wish), that you receive source code or can get it if you want it, that you can
change the software or use pieces of it in new free programs, and that you know you can do these
things.
To protect your rights, we need to prevent others from denying you these rights or asking you to
surrender the rights. Therefore, you have certain responsibilities if you distribute copies of the
software, or if you modify it: responsibilities to respect the freedom of others.
For example, if you distribute copies of such a program, whether gratis or for a fee, you must pass
on to the recipients the same freedoms that you received. You must make sure that they, too,
receive or can get the source code. And you must show them these terms so they know their rights.
Developers that use the GNU GPL protect your rights with two steps: (1) assert copyright on the
software, and (2) offer you this License giving you legal permission to copy, distribute and/or
modify it.
For the developers’ and authors’ protection, the GPL clearly explains that there is no warranty for
this free software. For both users’ and authors’ sake, the GPL requires that modified versions be
marked as changed, so that their problems will not be attributed erroneously to authors of previous
versions.
Some devices are designed to deny users access to install or run modified versions of the software
inside them, although the manufacturer can do so. This is fundamentally incompatible with the aim
of protecting users’ freedom to change the software. The systematic pattern of such abuse occurs
in the area of products for individuals to use, which is precisely where it is most unacceptable.
Therefore, we have designed this version of the GPL to prohibit the practice for those products. If
such problems arise substantially in other domains, we stand ready to extend this provision to
those domains in future versions of the GPL, as needed to protect the freedom of users.
Finally, every program is threatened constantly by software patents. States should not allow
patents to restrict development and use of software on general-purpose computers, but in those
that do, we wish to avoid the special danger that patents applied to a free program could make it
effectively proprietary. To prevent this, the GPL assures that patents cannot be used to render the
program non-free.
The precise terms and conditions for copying, distribution and modification follow.
TERMS AND CONDITIONS
0. Definitions
“This License” refers to version 3 of the GNU General Public License.
“Copyright” also means copyright-like laws that apply to other kinds of works, such as
semiconductor masks.
PN B38322AB
D-3
D
Third Party Contributions and Legal Notices
Contributions and Legal Notices
“The Program” refers to any copyrightable work licensed under this License. Each licensee is
addressed as “you”. “Licensees” and “recipients” may be individuals or organizations.
To “modify” a work means to copy from or adapt all or part of the work in a fashion requiring
copyright permission, other than the making of an exact copy. The resulting work is called a
“modified version” of the earlier work or a work “based on” the earlier work.
A “covered work” means either the unmodified Program or a work based on the Program.
To “propagate” a work means to do anything with it that, without permission, would make you
directly or secondarily liable for infringement under applicable copyright law, except executing it
on a computer or modifying a private copy. Propagation includes copying, distribution (with or
without modification), making available to the public, and in some countries other activities as well.
To “convey” a work means any kind of propagation that enables other parties to make or receive
copies. Mere interaction with a user through a computer network, with no transfer of a copy, is not
conveying.
An interactive user interface displays “Appropriate Legal Notices” to the extent that it includes a
convenient and prominently visible feature that (1) displays an appropriate copyright notice, and
(2) tells the user that there is no warranty for the work (except to the extent that warranties are
provided), that licensees may covey the work under this License, and how to view a copy of this
License. If the interface presents a list of user commands or options, such as a menu, a prominent
item in the list meets this criteria.
1. Source Code
The “source code” for a work means the preferred form of the work for making modifications to it.
“Object code” means any non-source form of a work.
A “Standard Interface” means an interface that either is an official standard defined by a recognized
standards body, or, in the case of interfaces specified for a particular programming language, one
that is widely used among developers working in that language.
The “System Libraries” of an executable work include anything, other than the work as a whole,
that (a) is included in the normal form of packaging a Major Component, but which is not part of
the Major Component, and (b) serves only to enable use of the work with that Major Component, or
to implement a Standard Interface for which an implementation is available to the public in source
code form. A “Major Component”, in this context, means a major essential component (kernel,
window system, and so on) of the specific operating system (if any) on which the executable work
runs, or a compiler used to produce the work, or an object code interpreter used to run it.
The “Corresponding Source” for a work in object code form means all the source code needed to
generate, install, and (for an executable work) run the object code and to modify the work,
including scripts to control those activities. However, it does not include the work’s System
Libraries, or general-purpose tools or generally available free programs which are used unmodified
in performing those activities but which are not part of the work. For example, Corresponding
Source includes interface definition files associated with source files for the work, and the source
code for shared libraries and dynamically linked subprograms that the work is specifically designed
to require, such as by intimate data communication or control flow between those subprograms
and other parts of the work.
The Corresponding Source need not include anything that users can regenerate automatically from
other parts of the Corresponding Source.
D-4
PN B38322AB
Third Party Contributions and Legal Notices
Contributions and Legal Notices
The Corresponding Source for a work in source code form is that same work.
2. Basic Permissions
All rights granted under this License are granted for the term of copyright on the Program, and are
irrevocable provided the stated conditions are met. This License explicitly affirms your unlimited
permission to run the unmodified Program. The output from running a covered work is covered by
this License only if the output, given its content, constitutes a covered work. This license
acknowledges yours rights of fair use or other equivalent, as provided by copyright law.
You may make, run, and propagate covered works that you do not convey, without conditions so
long as your license otherwise remains in force. You may convey covered works to others for the
sole purpose of having them make modifications exclusively for you, or provide you with facilities
for running those works, provided that you comply with the terms of this License in conveying all
material for which you do not control copyright. Those thus making or running the covered works
for you must do so exclusively on your behalf, under your direction and control, on terms that
prohibit them from making any copies of your copyrighted material outside their relationship with
you.
Conveying under any other circumstances is permitted solely under the conditions stated below.
Sublicensing is not allowed, section 10 makes it unnecessary.
3. Protecting Users’ Legal Rights From Anti-Circumvention Law
No covered work shall be deemed part of an effective technological measure under any applicable
law fulfilling obligations under article 11 of the WIPO copyright treaty adopted on 20 December
1996, or similar laws prohibiting or restricting circumvention of such measures.
When your convey a covered work, you waive any legal power to forbid circumvention of
technological measures to the extent such circumvention is effected by exercising rights under this
License with respect to the covered work, and you disclaim any intention to limit operation or
modification of the work as a means of enforcing, against the work’s users, your or third parties’
legal rights to forbid circumvention of technological measures.
4. Conveying Verbatim Copies
You may convey verbatim copies of the Program’s source code as you receive it, in any medium,
provided that you conspicuously and appropriately publish on each copy an appropriate copyright
notice; keep intact all notices stating that this License and any non-permissive terms added in
accord with section 7 apply to the code; keep intact all notices of the absence of any warranty; and
give all recipients a copy of this License along with the Program.
You may charge any price or no price for each copy that you convey, and you may offer support or
warranty protection for a fee.
5. Conveying Modified Source Versions
You may convey a work based on the Program, or the modifications to produce it from the Program,
in the form of source code under the terms of section 4, provided that you also meet all of these
conditions:
• a) The work must carry prominent notices stating that you modified it, and giving a relevant
date.
• b) The work must carry prominent notices stating that it is released under this License and any
conditions added under section 7. This requirement modifies the requirement in section 4 to
“keep intact all notices”.
• c) You must license the entire work, as a whole, under this License to anyone who comes into
possession of a copy. This License will therefore apply, along with any applicable section 7
PN B38322AB
D-5
D
Third Party Contributions and Legal Notices
Contributions and Legal Notices
additional terms, to the whole of the work and all its parts, regardless of how they are packaged.
This License gives no permission to license the work in any other way, but it does not invalidate
such permission if you have separately received it.
• d) If the work has interactive user interfaces, each must display Appropriate Legal Notices;
however, if the Program has interactive interfaces that do not display Appropriate Legal
Notices, your work need not make them do so.
A compilation of a covered work with other separate and independent works, which are not by their
nature extensions of the covered work, and which are not combined with it such as to form a larger
program, in or on a volume of a storage or distribution medium, is called an “aggregate” if the
compilation and its resulting copyright are not used to limit the access or legal rights of the
compilation’s users beyond which the individual works permit. Inclusion of a covered work in an
aggregate does not cause the License to apply to the other parts of the aggregate.
6. Conveying Non-Source Forms.
You may convey a covered work in object code form under the terms of sections 4 and 5, provided
that you also convey the machine-readable Corresponding Source under the terms of this LIcense,
in one of these ways:
• a) Convey the object code in, or embodied in, a physical product (including a physical
distribution medium), accompanied by the Corresponding Source fixed on a durable physical
medium customarily used for software interchange.
• b) Convey the object code in, or embodied in, a physical product (including a physical
distribution medium), accompanied by a written offer, valid for at least three years and valid
for as long as you offer spare parts or customer support for that product model, to give anyone
who possesses the object code either (1) a copy of the Corresponding Source for all the software
in the product that is covered by this License, on a durable physical medium customarily used
for software interchange, for a price no more than your reasonable cost of physically
performing this conveying of source, or (2) access to copy the Corresponding Source from a
network server at no charge.
• c) Convey individual copies of the object code with a copy of the written offer to provide the
Corresponding Source. This alternative is allowed only occasionally and noncommercially, and
only if you received the object code with such an offer in accord with subsection 6b.
• d) Convey the object code by offering access from a designated place (gratis or for a charge),
and offer equivalent access to the Corresponding Source in the same way through the same
place at no further charge. You need not require recipients to copy the Corresponding Source
along with the object code. If the place to copy the object code is a network server, the
Corresponding Source may be on a different server (operated by you or a third party) that
supports equivalent copying facilities, provided you maintain clear directions next to the
object code saying where to find the Corresponding Source. Regardless of what server hosts the
Corresponding Source, you remain obligated to ensure that it is available for as long as needed
to satisfy these requirements.
• E) Convey the object code using peer-to-peer transmission, provided you inform other peers
where the object code and Corresponding Source of the work are being offered to the general
public at no charge under subsection 6d.
A separable portion of the object code, whose source code is excluded from the Corresponding
Source as a System Library, need not be included in conveying the object code work.
D-6
PN B38322AB
Third Party Contributions and Legal Notices
Contributions and Legal Notices
A “User Product” is either (1) a “consumer product”, which means any tangible personal property
which is normally used for personal, family, or household purposes, or (2) anything designed or sold
for incorporation into a dwelling. In determining whether a product is a consumer product,
doubtful cases shall be resolved in favor of coverage. For a particular product received by a
particular user, “normally used” refers to a typical or common use of that class of product,
regardless of the status of the particular user or of the way in which the particular user actually
uses, or expects or is expected to use, the product. A product is a consumer product regardless of
whether the product has substantial commercial, industrial or non-consumer uses, unless such uses
represent the only significant mode of use of the product.
“Installation Information” for a User Product means any methods, procedures, authorization keys,
or other information required to install and execute modified versions of a covered work in that
User Product from a modified version of its Corresponding Source. The information must suffice to
ensure that the continued functioning of the modified object code is in no case prevented or
interfered with solely because modification has been made.
If you convey an object code work under this section in, or with, or specifically for use in, a User
Product, and the conveying occurs as part of a transaction in which the right of possession and use
of the User Product is transferred to the recipient in perpetuity or for a fixed term (regardless of
how the transaction is characterized), the Corresponding Source conveyed under the section must
be accompanied by the Installation Information. But this requirement does not apply if neither you
nor any third party retains the ability to install modified object code on the User Product (for
example, the work has been installed in ROM). The requirement to provide Installation Information
does not include a requirement to continue to provide support service, warranty, or updates for a
work that has been modified or installed by the recipient, or for the User Product in which it has
been modified or installed. Access to a network may be denied when the modification itself
materially and adversely affects the operation of the network or violates the rules and protocols for
communication across the network.
Corresponding Source conveyed, and Installation Information provided, in accord with this section
must be in a format that is publicly documented (and with the implementation available to the
public in source code form), and must require no special password or key for unpacking, reading or
copying.
7. Additional Terms.
“Additional permissions” are terms that supplement the terms of this license by making exceptions
from one or more of its conditions. Additional permissions that are applicable to the entire Program
shall be treated as though they were included in this License, to the extent that they are valid under
applicable law. If additional permissions apply only to part of the Program, that part may be used
separately under those permissions, but the entire Program remains governed by this License
without regard to the additional permissions.
When you convey a copy of a covered work, you may at your option remove any additional
permissions from that copy, or from any part of it. (Additional permissions may be written to
require their own removal in certain cases when you modify the work. ) You may place additional
permissions on material, added by you to a covered work, for which you have or can give,
appropriate copyright permission.
PN B38322AB
D-7
D
Third Party Contributions and Legal Notices
Contributions and Legal Notices
Notwithstanding any other provisions of this License, for material you add to a covered work, you
may (if authorized by the copyright holders of that material) supplement the terms of this License
with terms:
• a) Disclaiming warranty or limiting liability differently from the terms of sections 15 and 16 of
this License; or
• b) Requiring preservation of specified reasonable legal notices or author attribution in that
material or in the Appropriate Legal Notices displayed by works containing it; or
• c) Prohibiting misrepresentation of the origin of that material, or requiring that modified
versions of such material be marked in reasonable ways as different from the original version;
or
• d) Limiting the use for publicity purposes of names of licensors or authors of the material; or
• e) Declining to grant rights under trademark law for use of some trade names, trademarks, or
service marks; or
• f) Requiring indemnification of licensors and authors of that material by anyone who conveys
the material (or modified versions of it) with contractual assumptions of liability to the
recipient, for any liability that these contractual assumptions directly impose on those
licensors and authors.
All other non-permissive additional terms are considered “further restrictions” within the meaning
of section 10. If the Program as you received it, or any part of it, contains a notice stating that it is
governed by the License along with a term that is a further restriction, you may remove that term.
If a license document contain s a further restriction but permits relicensing or conveying under this
License, you may add to a covered work material governed by the terms of that license document,
provided that the further restriction does not survive such relicensing or conveying.
If you add terms to a covered work in accord with this section, you must place, in the relevant
source files, a statement of the additional terms that apply to those files, or a notice indicating
where to find the applicable terms.
Additional terms, permissive or non-permissive, may be stated in the form of a separately written
license, or stated as exceptions; the above requirements apply either way.
8. Termination.
You may not propagate or modify a covered work except as expressly provided under this License.
any attempt otherwise to propagate or modify it is void, and will automatically terminate your
rights under this License (including any patent licenses granted under the third paragraph of
section 11).
However, if you cease all violation of this License, then your license from a particular copyright
holder is reinstated (a) provisionally, unless and until the copyright holder explicitly and finally
terminates your license, and (b) permanently, if the copyright holder fails to notify you of the
violation by some reasonable means prior to 60 days after the cessation.
Moreover, your license from a particular copyright holder is reinstated permanently if the
copyright holder notifies you of the violation by some reasonable means, this is the first time you
have received notice of violation of this License (for any work) from that copyright holder, and you
cure the violation prior to 30 days after your receipt of the notice.
Termination of your rights under this section does not terminate the licenses of parties who have
received copies or rights from you under this License. If your rights have been terminated and not
D-8
PN B38322AB
Third Party Contributions and Legal Notices
Contributions and Legal Notices
permanently reinstated, you do not qualify to receive new licenses for the same material under
section 10.
9. Acceptance Not Required for Having Copies.
Your are not required to accept this License in order to receive or run a copy of the Program.
Ancillary propagation of a covered work occurring solely as a consequence of using peer-to-peer
transmission to receive a copy likewise does not require acceptance. However, nothing other than
this License grants you permission to propagate or modify any covered work. These actions infringe
copyright if you do not accept this License. Therefore, by modifying or propagating a covered work,
you indicate your acceptance of this License to do so.
10. Automatic Licensing of Downstream Recipients.
Each time you convey a covered work, the recipient automatically receives a license from the
original licensors, to run, modify and propagate that work, subject to this License. You are not
responsible for enforcing compliance by third parties with this License.
An “entity transaction” is a transaction transferring control of an organization, or substantially all
assets of one, or subdividing an organization, or merging organizations. If propagation of a covered
work results from an entity transaction, each party to that transaction who receives a copy of the
work also receives whatever licenses to the work the party’s predecessor in interest had or could
give under the previous paragraph, plus a right to possession of the Corresponding Source of the
work from the predecessor in interest, if the predecessor has it or can get it with reasonable efforts.
You may not impose any further restrictions on the exercise of the rights granted or affirmed under
this License. For example, you may not impose a license fee, royalty, or other charge for exercise of
rights granted under this License, and you may not initiate litigation (including a cross-claim or
counterclaim in a lawsuit) alleging that any patent claim is infringed by making, using, selling,
offering for sale, or importing the Program or any portion of it.
11. Patents.
A “contributor” is a copyright holder who authorizes use under this License of the Program or a
work on which the Program is based. The work thus licensed is called the contributor’s “contributor
version”.
A contributor’s “essential patent claims” are all patent claims owned or controlled by the
contributor, whether already acquired or hereafter acquired, that would be infringed by some
manner, permitted by this License, of making, using, or selling its contributor version, but do not
include claims that world be infringed only as a consequence of further modification of the
contributor version. For purposes of this definition, “control” includes the right to grant patent
sublicenses in a manner consistent with the requirements of the License.
Each contributor grants you a non-exclusive, worldwide, royalty-free patent license under the
contributor’s essential patent claims, to make, use, sell, offer for sale, import and otherwise run,
modify and propagate the contents of its contributor version.
In the following three paragraphs, a “patent license” is any express agreement or commitment,
however denominated, not to enforce a patent (such as an express permission to practice a patent
or covenant not to sue for patent infringement). To “grant” such a patent license to a party means
to make such an agreement or commitment not to enforce a patent against the party.
If you convey a covered work, knowingly relying on a patent license, and the Corresponding Source
of the work is not available for anyone to copy, free of charge and under the terms of this License,
through a publicly available network server or other readily accessible means, then you must either
(1) cause the Corresponding Source to be so available, or (2) arrange to deprive yourself of the
benefit of the patent license for this particular work, or (3) arrange, in a manner consistent with the
PN B38322AB
D-9
D
Third Party Contributions and Legal Notices
Contributions and Legal Notices
requirements of this License, to extend the patent license to downstream recipients. “Knowingly
relying” means you have actual knowledge that, but for the patent license, your conveying the
covered work in a country, or your recipient’s use of the covered work in a country, would infringe
one or more identifiable patents in that country that you have reason to believe are valid.
If, pursuant to or in connection with a single transaction arrangement, you convey, or propagate by
procuring conveyance of, a covered work, and grant a patent license to some of the parties
receiving the covered work authorizing them to use, propagate, modify or convey a specific copy of
the covered work, then the patent license you grant is automatically extended to all recipients of
the covered work and works based on it.
A patent license is “discriminatory” if it does not include within the scope of its coverage, prohibits
the exercise of, or is conditioned on the non-exercise of one or more of the rights that are
specifically granted under this License. You may not convey a covered work if you are a party to an
arrangement with a third party that is in the business of distributing software, under which you
make payment to the third party based on the extent of your activity of conveying the work, and
under which the third party grants, to any of the parties who would receive the covered work from
you, a discriminatory patent license (a) in connection with copies of the covered work conveyed by
you (or copies made from those copies), or (b) primarily for and in connection with specific
products or compilations that contain the covered work, unless you entered into that arrangement,
or that patent license was granted, prior to 28 March 2007.
Nothing in this license shall be construed as excluding or limiting any implied license or other
defenses to infringement that may otherwise be available to you under applicable patent law.
12. No Surrender of Others’ Freedom.
If conditions are imposed on you (whether by court order, agreement or otherwise) that contradict
the conditions of this License, they do not excuse you from the conditions of this License. If you
cannot convey a covered work so as to satisfy simultaneously your obligations under this License
and any other pertinent obligations, then as a consequence you may not convey it at all. For
example, if you agree to terms that obligate you to collect a royalty for further conveying from
those to whom you convey the Program, the only way you could satisfy both those terms and this
License would be to refrain entirely from conveying the Program.
13. Use with the GNU Affero General Public License.
Notwithstanding any other provision of this License, you have permission to link or combine any
covered work with a work license under version 3 of the GNU Affero General Public License into a
single combined work, and to convey the resulting work. The terms of this License will continue to
apply to the part which is the covered work, but the special requirements of the GNU Affero General
Public License, section 13, concerning interaction through a network will apply to the combination
as such.
14. Revised Versions of this License.
The Free Software Foundation may publish revised and/or new versions of the GNU General Public
License from time to time. Such new versions will be similar in spirit to the present version, but may
differ in detail to address new problems or concerns.
Each version is given a distinguishing version number. If the Program specifies that a certain
numbered version of the GNU General Public License “or any later version” applies to it, you have
the option of following the terms and conditions either of that numbered version or of any later
version published by the Free Software Foundation. If the Program does not specify a version
number of the GNU General Public License, you may choose any version ever published by the Free
Software Foundation.
D-10
PN B38322AB
Third Party Contributions and Legal Notices
Contributions and Legal Notices
If the Program specifies that a proxy can decide which future versions of the GNU General Public
License can be used, that proxy’s public statement of acceptance of a version permanently
authorizes you to choose that version for the Program.
Later license versions may give you additional or different permissions. However, no additional
obligations are imposed on any author or copyright holder as a result of your choosing to follow a
later version.
15. Disclaimer of Warranty.
THERE IS NO WARRANTY FOR THE PROGRAM, TO THE EXTENT PERMITTED BY APPLICABLE LAW.
EXCEPT WHEN OTHERWISE STATED IN WRITING THE COPYRIGHT HOLDERS AND/OR OTHER
PARTIES PROVIDE THE PROGRAM “AS IS” WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESSED
OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY
AND FITNESS FOR A PARTICULAR PURPOSE. THE ENTIRE RISK AS TO THE QUALITY AND
PERFORMANCE OF THE PROGRAM IS WITH YOU. SHOULD THE PROGRAM PROVE DEFECTIVE, YOU
ASSUME THE COST OF ALL NECESSARY SERVICING, REPAIR OR CORRECTION.
16. Limitation of Liability.
IN NO EVENT UNLESS REQUIRED BY APPLICABLE LAW OR AGREED TO IN WRITING WILL ANY
COPYRIGHT HOLDER, OR ANY OTHER PARTY WHO MODIFIES AND/OR CONVEYS THE PROGRAM AS
PERMITTED ABOVE, BE LIABLE TO YOU FOR DAMAGES, INCLUDING ANY GENERAL, SPECIAL,
INCIDENTAL OR CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE OR INABILITY TO USE THE
PROGRAM (INCLUDING BUT NOT LIMITED TO LOSS OF DATA OR DATA BEING RENDERED
INACCURATE OR LOSSES SUSTAINED BY YOU OR THIRD PARTIES OR A FAILURE OF THE PROGRAM
TO OPERATE WITH ANY OTHER PROGRAMS), EVEN IF SUCH HOLDER OR OTHER PARTY HAS BEEN
ADVISED OF THE POSSIBILITY OF SUCH DAMAGES.
17. Interpretation of Sections 15 and 16.
If the disclaimer of warranty and limitation of liability provided above cannot be given local legal
effect according to their terms, reviewing courts shall apply local law that most closely
approximates an absolute waiver of all civil liability in connection with the Program, unless a
warranty or assumption of liability accompanies a copy of the Program in return for a fee.
END OF TERMS AND CONDITIONS
PN B38322AB
D-11
D
Third Party Contributions and Legal Notices
Contributions and Legal Notices
D-12
PN B38322AB
APPENDIX E
HEPA Filter Replacement Instructions for the
Avanti JXN Series Centrifuges
HEPA Filter Replacement
The external HEPA filter is located on the left side of the centrifuge. To replace the filter assembly,
remove the tubing from the plastic barbed fitting protruding from the side of the centrifuge. Install
the new filter assembly (B45269) ensuring the arrow on the filter is pointing down.
Figure E.1 HEPA Filter Replacement
1. Arrow to point down
PN B38322AB
E-1
HEPA Filter Replacement Instructions for the Avanti JXN Series Centrifuges
HEPA Filter Replacement
E-2
PN B38322AB
Abbreviations
A — Ampere
KB — Kilobyte
ACA — Australian Communication Authority
kg — Kilograms
API — Application Programming Interface
kW — Kilowatt
Btu — British Thermal Unit
lb — Pound
°C — Degrees Celsius or Degrees Centigrade
LCD — Liquid-Crystal Display
cm — Centimeter
m — Meter
CE — Conformite European Marking signifying
compliance with applicable European directives
mm — Millimeter
CFC — Chloroflorocarbon
dBA — Decibel
DHCP — Dynamic Host Configuration Protocol
DNS — Domain Name System
DRIC — Dynamic Rotor Inertia Check
EFUP — Environmentally Friendly Use Period
ESD — Electrostatic discharge
°F — Degrees Fahrenheit
ft — Foot
FRS — Friction Reduction System
g — Grams
HEPA — High Efficiency Particulate Air
Hr — Hour
Hz — Hertz
ID — Identification
in. — Inches
mL — Milliliter
mm Hg — Millimeter of mercury
MSDS — Material Safety Data Sheet
NRTL — Nationally Recognized Testing Laboratory
OEM — Original Equipment Manufacturer
Pa — Pascals
PN — Part Number
RCF — Relative Centrifugal Field
RPM — Rotations per Minute
UNC — Universal Naming Convention
USB — Universal Serial Bus
USPTO — US Patent and Trademark Office
V — Volt
VAC — Voltage Alternating Current
VNC — Virtual Network Computing
W — Watt
WEEE — Waste Electrical and Electronic Equipment
IP — Internet Protocol
IEEE — Institute of Electrical and Electronics Engineers
ISO — International Organization for Standardization
IVD — In-Vitro Diagnostic
PN B38322AB
Abbreviations-1
Abbreviations
Abbreviations-2
PN B38322AB
Index
Symbols
°C
defined, Abbreviations-1
°F
defined, Abbreviations-1
A
A
defined, Abbreviations-1
about
manual, -xxvii
about page, 2-9, 6-56
displaying, 2-9
about your instrument, 2-8
ACA
defined, Abbreviations-1
acceleration and deceleration settings
example, 6-13
accessing
rotor in case of power failure, 7-6
add to rotor library page, 6-43
add/edit user page, 6-53
adding
rotors, 4-8
users, 4-5
additional requirements for three-phase power
connections
preinstallation requirements, A-4
administrator user levels, 4-5
air filter
replacing, 7-4
alerts
safety, -v
API
defined, Abbreviations-1
to enable, 4-4
archive data page, 6-47
areas on the screen, 2-2
accel and decel display/button, 2-6
footer bar, 2-4
footer bar on other pages, 2-5
footer bar on the home page, 2-5
header bar, 2-2
help button, 2-4
home page button, 2-2
menu button, 2-3
page display area, 2-6
start button, 2-4
status display, 2-3
stop button, 2-5
system name, 2-6
audible sounds
specifications, 1-7
authorize programs page, 6-54
authorize users page, 6-21
auto export
enable, 4-16
run history data, 4-16
auto print
enable, 4-16
run history data, 4-16
available rotors, 1-7
B
basic tab, 6-30
before run comment page, 4-18
before run/after run comment page, 6-28
Btu
defined, Abbreviations-1
C
calibrating
temperature, B-1
CE
Index-1
Index
defined, Abbreviations-1
centrifugation
function, 1-2
certification, -xxviii
CFC
defined, Abbreviations-1
CFC-free centrifugation, -xxix
changing
defaults for logout timer, 4-6
defaults for PIN expiration, 4-6
changing user options, 4-7
checking for rotor drive pins, A-5
cleaning
the instrument, 7-2
tube breakage, 7-3
cm
defined, Abbreviations-1
continuous flow page, 3-11
conventions, -xxviii
copyright
software, -xxix
creating
programs, 5-2
custom sounds page, 6-46
D
dBA
defined, Abbreviations-1
decontamination, 7-3
delay start page, 3-7, 6-9
deleting
programs, 5-8
DHCP
defined, Abbreviations-1
diagnostic history page, 6-44
diagnostics/user messages, 7-6, C-1
disclaimer
graphics, xxxi
display
about page, 2-9
DNS
defined, Abbreviations-1
door release
emergency latch access, 7-7
manual, 7-8
DRIC
defined, Abbreviations-1
drive, 1-3
E
editing
programs, 5-7
EFUP
defined, Abbreviations-1
electrical
preinstallation requirements, A-1
email
setup, 4-2
emergency door release latch access, 7-7
enable
e-signature, 4-18
enabling
API, 4-4
auto export, 4-16
auto print, 4-16
run comments, 4-17
ESD
defined, Abbreviations-1
e-signature, 4-18
enable, 4-18
using, 4-19
example
acceleration and deceleration settings, 6-13
export data, 4-14
export page, 6-20
exporting
run history data to a USB drive
(manually), 4-14
run history data to mapped network
(manually), 4-15
F
features
safety, 1-4
field service, 7-1
filtering data, 4-10
friction reduction system, 1-3
FRS, 1-3
defined, Abbreviations-1
ft
defined, Abbreviations-1
function
centrifugation, 1-2
G
g
defined, Abbreviations-1
Index-2
Index
graphics, -xxxi
graphics disclaimer, xxxi
graphing
data for a previously completed run, 4-12
data for a run in progress, 4-12
graphing data, 4-12
H
header bar
error message, 2-4
ready status, 2-3
running status, 2-3
stopping status, 2-4
warning message, 2-4
help messages, 2-6
global help, 2-6
item help, 2-6
HEPA
defined, Abbreviations-1
home page, 2-1, 3-2, 6-3
home page (run in progress), 6-5
housing and door, 1-3
Hr
defined, Abbreviations-1
Hz
defined, Abbreviations-1
I
ID
defined, Abbreviations-1
IEEE
defined, Abbreviations-1
import page, 6-22
in.
defined, Abbreviations-1
instrument
cleaning, 7-2
instrument labels
summary, -x
intended use
for in vitro diagnostic use, 1-1
IVD, 1-1
IP
defined, Abbreviations-1
ISO
defined, Abbreviations-1
IVD
defined, Abbreviations-1
J
JCF-Z
rotor identification, 7-11
JCF-Z continuous flow/zonal rotor
using, A-7
K
KB
defined, Abbreviations-1
kg
defined, Abbreviations-1
kW
defined, Abbreviations-1
L
labels
for instrument, -x
lb
defined, Abbreviations-1
LCD
defined, Abbreviations-1
login page, 6-13
logout timer, 4-6
changing defaults, 4-6
M
m
defined, Abbreviations-1
maintenance, 7-1
manage rotors page, 6-42
manage users page, 6-52
managing
reports, 4-9
rotors, 4-7
users, 4-4
your network, 4-1
manual
scope, -xxviii
manual door release, 7-8
manual operation, 3-1
manual overview, xxvii
manually
operating the run, 3-1
manually exporting
run history data to a mapped network, 4-15
run history data to a USB drive, 4-14
menu page, 6-29
Index-3
Index
mL
defined, Abbreviations-1
mm
defined, Abbreviations-1
mm Hg
defined, Abbreviations-1
MSDS
defined, Abbreviations-1
N
name rating plate, 1-2
network
setup, 4-1
network tab, 6-32
new program name page, 5-4
new step in numbered sequence page, 5-6
new step page, 5-5
new/edit step page, 6-18
new/edit/view program page, 6-15
notices
safety, -vii
NRTL
defined, Abbreviations-1
O
OEM
defined, Abbreviations-1
operating the run
manually, 3-1
operation
zonal and continuous flow, 3-9
operator user level, 4-5
overtemp system, 1-4
P
Pa
defined, Abbreviations-1
page
,manage rotors, 6-42
about, 2-9, 6-56
add to rotor library, 6-43
add/edit user, 6-53
archive data, 6-47
authorize programs, 6-54
authorize users, 6-21
before run comment, 4-18
before run/after run comment, 6-28
Index-4
continuous flow, 3-11
custom sounds, 6-46
delay start, 3-7, 6-9
diagnostic history, 6-44
export, 6-20
home, 2-1, 3-2, 6-3
home (run in progress), 6-5
home page, 5-2
import, 6-22
login, 6-13
manage users, 6-52
menu, 6-29
new program name, 5-4
new step, 5-5
new step in numbered sequence, 5-6
new/edit step, 6-18
new/edit/view program, 6-15
program log, 6-19
real-time run data/historical run data, 6-23
reset user PIN, 6-38
rotor catalog, 6-55
run graph options, 4-13, 6-24
run history, 4-9, 4-15, 6-25
run history filter, 4-10, 6-27
select image, 6-39
select language, 6-35
select printer, 6-49
select program, 5-3, 6-14
select rotor, 3-4, 5-5
select rotor (catalog), 6-17
select rotor (library), 6-7
set acceleration/deceleration profiles, 3-5,
5-4, 6-12
set date and time, 6-40
set from date and time, 4-11
set sound, 6-45
set speed, 3-3, 6-6
set speed ω²t time, 6-10
set temperature, 3-8, 6-11
set time, 3-6, 6-8
setup email, 6-50
setup network, 6-48
setup VNC, 6-51
signature, 4-19
system log, 6-41
system options, 6-30
unnamed program, 5-3
user options, 6-36
zonal, 3-10
Index
zonal authorization, 6-57
zonal operation, 6-58
zonal operation with cancel button, 3-3
performing
instrument maintenance, 7-2
PIN experation, 4-6
PIN expiration
changing defaults, 4-6
PN
defined, Abbreviations-1
preinstallation
electrical requirements, A-1
requirements, A-1
single and three-phase power connection
requirements, A-2
space and location, A-4
three-phase power connections additional
requirements, A-4
print
run history from the run graph page, 4-13
run history from the run history page, 4-14
print data, 4-13
printer
selection, 4-2
program log page, 6-19
programs
creating, 5-2
deleting, 5-8
editing, 5-7
running, 5-6
R
RCF
defined, Abbreviations-1
real-time run data/historical run data
page, 6-23
replacement parts, 7-12
replacing
air filter, 7-4
reports tab, 6-34
requirements
preinstallation, A-1
requiring
login, 4-5
reset user PIN page, 6-38
rotor catalog page, 6-55
rotor chamber, 1-3
rotor identification
JCF-Z, 7-11
rotors
adding, 4-8
RPM
defined, Abbreviations-1
run comments
enable, 4-17
use, 4-17
run graph options page, 4-13, 6-24
run history data
auto export, 4-16
auto print, 4-16
run history filter page, 4-10, 6-27
run history page, 4-9, 4-15, 6-25
running
programs, 5-6
S
safety
alerts, -v
features, 1-4
notices, -vii
scope of manual, -xxviii
select image page, 6-39
select language page, 6-35
select printer page, 6-49
select program page, 5-3, 6-14
select rotor page, 3-4, 5-5
select rotor page (catalog), 6-17
select rotor page (library), 6-7
selecting
a printer, 4-2
set acceleration/deceleration profiles page, 3-5,
5-4, 6-12
set date and time page, 6-40
set from date and time page, 4-11
set sound page, 6-45
set speed page, 3-3, 6-6
set speed ω²t time page, 6-10
set temperature page, 3-8, 6-11
set time page, 3-6, 6-8
setting the
acceleration and deceleration profiles, 3-5
speed and rotor, 3-4
temperature, 3-8
time, 3-6
setting up
email, 4-2
the network, 4-1
VNC, 4-3
Index-5
Index
setup email page, 6-50
setup network page, 6-48
setup VNC page, 6-51
signature page, 4-19
single and three-phase power connection
preinstallation requirements, A-2
software
copyright, -xxix
space and location
preinstallation requirements, A-4
specifications
audible sounds, 1-7
J-26S XPI, 1-5
J-30I, 1-5
step 1
start on the home page, 3-2
step 2
set the speed and rotor, 3-3
step 3
set the acceleration and deceleration
profiles, 3-4
step 4
set the time, 3-6
step 5
set the temperature, 3-8
step 6
start the run, 3-8
sterilization and disinfection, 7-4
storage and transportation, 7-11
replacement parts, 7-12
supply list, 7-12
super user level, 4-5
supply list, 7-12
symbols, -xxx
system
overtemp, 1-4
system log page, 6-41
system options page, 6-30
system tab, 6-31
T
tab
basic, 6-30
network, 6-32
system, 6-31
users, 6-33
temperature
calibration, B-1
temperature control, 1-3
Index-6
temperature sensing, 1-3
touch screen, 1-2
tube breakage
cleaning, 7-3
U
UNC
defined, Abbreviations-1
unnamed program page, 5-3
USB
defined, Abbreviations-1
user
changing options, 4-7
options, 4-7
user access, 4-9
user levels, 4-5
administrator, 4-5
operator, 4-5
super user, 4-5
user options page, 6-36
users tab, 6-33
using
e-signature, 4-19
JCF-Z continuous flow/zonal rotor, A-7
run comments, 4-17
using J2 series rotors in the Avanti J-26S XPI, A-5
USPTO
defined, Abbreviations-1
V
V
defined, Abbreviations-1
VAC
defined, Abbreviations-1
VNC
defined, Abbreviations-1
setup, 4-3
W
W
defined, Abbreviations-1
WEEE
defined, Abbreviations-1
Z
zonal and continuous flow operation, 3-9
Index
zonal authorization page, 6-57
zonal operation page, 6-58
zonal or continuous flow run
seven phases, 3-10
zonal or continuous flow run seven phases
finishing, 3-10, 3-12
loading, 3-10, 3-11
preparing, 3-10
running, 3-10, 3-12
starting, 3-10, 3-11
stopping, 3-10, 3-12
unloading, 3-10, 3-12
zonal page, 3-10
Index-7
Index
Index-8
Beckman Coulter, Inc.
Avanti JXN Series Centrifuge Warranty
Subject to the exceptions and upon the conditions specified below Beckman Coulter, Inc. agrees to
correct either by repair, or, at its election, by replacement, any defects of material or workmanship
which develop within one (1) year (3 years for the drive motor) after delivery of the Avanti JXN
Series Centrifuge (the product), to the original buyer by Beckman Coulter or by an authorized
representative, provided that investigation and factory inspection by Beckman Coulter discloses
that such defect developed under normal and proper use.
Some components and accessories by their nature are not intended to and will not function for as
long as one (1) year. If any such component or accessory fails to give reasonable service for a
reasonable period of time, Beckman Coulter will repair or, at its election, replace such component
or accessory. What constitutes either reasonable service and a reasonable period of time shall be
determined solely by Beckman Coulter.
Replacement
Any product claimed to be defective must, if requested by Beckman Coulter, be returned to the
factory, transportation charges prepaid, and will be returned to Buyer with the transportation
charges collect unless the product is found to be defective, in which case Beckman Coulter will pay
all transportation charges.
Beckman Coulter makes no warranty concerning products or accessories not manufactured by it.
In the event of failure of any such product or accessory, Beckman Coulter will give reasonable
assistance to the Buyer in obtaining from the respective manufacturer whatever adjustment is
reasonable in light of the manufacturer’s own warranty.
Conditions
Beckman Coulter shall be released from all obligations under all warranties, either expressed or
implied, if the product covered hereby is repaired or modified by persons other than its own
authorized service personnel, unless such repair by others is made with the written consent of
Beckman Coulter, or unless such repair in the sole opinion of Beckman Coulter is minor, or unless
such modifications is merely the installation of a new Beckman Coulter plug-in component for such
product.
Disclaimer
IT IS EXPRESSLY AGREED THAT THE ABOVE WARRANTY SHALL BE IN LIEU OF ALL WARRANTIES OF
FITNESS AND OF THE WARRANTY OF MERCHANTABILITY AND THAT BECKMAN COULTER, INC.
SHALL HAVE NO LIABILITY FOR SPECIAL OR CONSEQUENTIAL DAMAGES OF ANY KIND
WHATSOEVER ARISING OUT OF THE MANUFACTURE, USE, SALE, HANDLING, REPAIR,
MAINTENANCE, OR REPLACEMENT OF THE PRODUCT.
PN B38322AB
Warranty-1
Beckman Coulter, Inc. Avanti JXN Series Centrifuge Warranty
Warranty-2
PN B38322AB
Related Documents
Rotors and Tubes for
Beckman Coulter J2, J6,and
Avanti J Series Centrifuges
PN JR-IM-10
• Rotors
• Tubes, Bottles, and
Accessories
• Using Tubes and
Accessories
• Using Fixed-Angle Rotors
• Using Swinging-Bucket
Rotors
• Using Vertical-Tube and
Rack Type Rotors
• Care and Maintenance
• Chemical Resistances
• Temperature
Compensation Tables
• Gradient Materials
High-Performance and
High-Capacity Centrifuges
Catalog
PN BR-8102
Available at
www.beckmancoulter.com
Preinstallation Requirements
for Avanti JXN Series
Centrifuges
PN B39493
Available at
www.beckmancoulter.com
Available in electronic pdf or
CD-ROM by request.
Chemical Resistances for
Beckman Coulter
Centrifugation Products
PN IN-175
Available in hard copy or
electronic pdf by request.
Available at
www.beckmancoulter.com
www.beckmancoulter.com
© 2014 Beckman Coulter, Inc.
All Rights Reserved