Download APT-6S / APT-6SB - Anly Electronics Co., Ltd.

Transcript
APT-6S / APT-6SB
WEEKLY PROGRAMMABLE TIMER
User's Manual
SAFETY PRECAUTION This manual uses the following symbols to ensure safe operation of this timer.
Warnings are indicated when mishandling this controller might result in death or serious injury
to user.
Cautions are indicated when mishandling this controller might result in minor injury to the user,
or only physical damage to the timer.
WARNING
CAUTION
WARNING
RESTRICTIONS ON USE
When using this product in applications
that require particular safety or when
using this product in important facilities,
please pay attention to the safety of the
overall system and equipment. Install failsafe mechanisms, perform redundancy
checks and periodic inspections and
adopt other appropriate safety measures
when it is necessary. This product is rated
at Class ҈
.
ΘNote this incorrect wiring of this controller can damage it and lead to other hazards. Make sure the controller has
been correctly wired before turning the power ON.
ΘBefore wiring, or removing / mounting the controller, be sure to turn the power OFF. Failure to do so might cause
electric shock.
ΘDo not touch electrically charged parts such as the power terminals. Doing so might cause electric shock.
ΘDo not disassemble the controller. Doing so might cause electric shock or faulty operation.
CAUTION
ΘUse the controller within the operating ranges recommended in the specification (temperature, humidity, voltage,
shock, mounting direction, atmosphere and etc.). Failure to do so might cause fire or faulty operation.
ΘFirmly tighten the terminal screws. Insufficient tightening of terminal screws might cause electric shock or fire.
ΘPress reset before use after removing the insulation sheet or replace the battery.
SPECIFICATION
BUTTON and SWITCH FUNCTIONS
Operating voltage
AC/DC : 12 ~ 48V / AC/DC : 100 ~ 240V
Allowable operating
voltage range
85 ~ 110% of rated operating voltage
Rated frequency
Θ
: Porgram setting (ON/OFF) ΘOFF
SET
: Output contact is disabled
50 / 60 Hz
ΘCLOCK : Current time setting
ΘON
Contact rating
240VAC 7A(N.O.), 240VAC 5A(N.C.) Resistive load
Θʳ DAY
: Weekday setting
ΘAUTO : Output contact is controlled by
Indicator operating
POWER - Red / RELAY ON - Green
Power consumption
Approx. 3.3VA
ΘʳʳHR
: Hour setting
Life
Mechanical : 5,000,000 times / Electrical : 100,000 times
Θʳ MIN
: Minute setting
Ambient temperature -10 ~ +50 °C
program setting
ϡWhen switch to Auto mode from ON or OFF,
Γoutput contact will be kept in the previous
Γmode. Than, output contact will be controlled
Γby program setting.
ΘCLEAR : Clear setting
Ambient humidity
MAX 85% RH
Weight
Approx. 170g
Θ RESET : Program reset
CONNECTION
When APT and the load have
separate power source
: Output contact is enabled
OPERATING FLOWCHART
When APT and the load share
the same power source
N Type
SU MO TU WE TH FR SA
TU
TU
N Type
CLOCK
P ROGRA MM A B L E TIME R
P R OGR A MMA B LE TI ME R
DAY
CLOCK
SET WEEKDAY
HR
CLOCK
SET HOUR
MIN
SET MINUTE
SET
CURRENT TIME SETTING
SET
DAY
HR
MIN
SET
AUTO
ON
CLEAR OFF
CLOCK
DAY
CLOCK
HR
OFF
RED
MIN
AUTO
ON
CLEAR OFF
RESET
ON
GREEN
ON OFF
RESET
APT - 6S
ON
GREEN
OFF
RED
SE T
APT - 6S
SET
SET PROGRAM NUMBER
LOAD
PROGRAM SETTING
CLOCK
ON
SU MO TU WE TH FR SA
SE T
DAY
ON
MO
SE T
HR
SET WEEKDAY
SET HOUR
ON
MO
SE T
MIN
SET MINUTE
LOAD
LOAD
SOURCE
N
MO
SE T
CLEAR
PROGRAM ENABLE OR DISABLEϡ
ϡThe pervious setting will be
L
N
SOURCE
L
shown when press
SOURCE
CLEAR
once again.
CONVERT Y TYPE (Flush Mounting) TO N TYPE (Surface Mounting)
BATTERY CHANGE
ᢳ
ON
ᢴ
ᢳ
ᢴ
ᢵ
Lithium battery
CR2032
+
3 VOLTS
CONVERT N TYPE (Surface Mounting) TO Y TYPE (Flush Mounting)
BEFORE USE
Insulation Sheet
Pull
Before Use
Press reset before use
after removing the
insulation sheet
ᢳ
ᢴ
ᢵ
ᢶ
PROGRAMMABLE TIMER
SET
DAY
CLOCK
HR
MIN
AUTO
ON
CLEAR OFF
RESET
ON
GREEN
OFF
RED
APT - 6S
Reset
ANLY ELECTRONICS CO., LTD.
http://www.anly.com.tw
M-APT6-L-B
Printed in Taiwan