Transcript
APT-6S / APT-6SB SAFETY PRECAUTION This manual uses the following symbols to ensure safe operation of this timer. WEEKLY PROGRAMMABLE TIMER User's Manual Warnings are indicated when mishandling this controller might result in death or serious injury to user. Cautions are indicated when mishandling this controller might result in minor injury to the user, or only physical damage to the timer. WARNING CAUTION WARNING RESTRICTIONS ON USE When using this product in applications that require particular safety or when using this product in important facilities, please pay attention to the safety of the overall system and equipment. Install failsafe mechanisms, perform redundancy checks and periodic inspections and adopt other appropriate safety measures when it is necessary. ΘNote this incorrect wiring of this controller can damage it and lead to other hazards. Make sure the controller has been correctly wired before turning the power ON. ΘBefore wiring, or removing / mounting the controller, be sure to turn the power OFF. Failure to do so might cause electric shock. ΘDo not touch electrically charged parts such as the power terminals. Doing so might cause electric shock. ΘDo not disassemble the controller. Doing so might cause electric shock or faulty operation. CAUTION ΘUse the controller within the operating ranges recommended in the specification (temperature, humidity, voltage, shock, mounting direction, atmosphere and etc.). Failure to do so might cause fire or faulty operation. ΘFirmly tighten the terminal screws. Insufficient tightening of terminal screws might cause electric shock or fire. SPECIFICATION BUTTON and SWITCH FUNCTIONS Operating voltage AC/DC : 12 ~ 48V / AC/DC : 100 ~ 240V Allowable operating voltage range 85 ~ 110% of rated operating voltage Rated frequency 50 / 60 Hz ΘCLOCK : Current time setting ΘON Contact rating 240VAC 7A(N.O.), 240VAC 5A(N.C.) Resistive load Θʳ DAY : Weekday setting ΘAUTO : Output contact is controlled by Indicator operating POWER - Red / RELAY ON - Green ΘʳʳHR : Hour setting Θʳ MIN : Minute setting Θ Power consumption Approx. 3.3VA Life Mechanical : 5,000,000 times / Electrical : 100,000 times Ambient temperature -10 ~ +50 °C Ambient humidity MAX 85% RH Weight Approx. 170g SET : Porgram setting (ON/OFF) ΘOFF program setting ΘCLEAR : Clear setting Θ RESET : Program reset OPERATING FLOWCHART When a time switch and load power supply are the same. N Type CLOCK DAY CLOCK SU MO TU WE TH FR SA N Type P ROGRA MM A B L E TIME R : Output contact is enabled ϡWhen switch to Auto mode from ON or OFF, Γoutput contact will be kept in the previous Γmode. Than, output contact will be controlled Γby program setting. CONNECTION When a time switch and load power supply are separate. : Output contact is disabled P R OGR A MMA B LE TI ME R HR CLOCK TU SET WEEKDAY MIN TU SET HOUR SET MINUTE SET CURRENT TIME SETTING SET DAY CLOCK HR MIN SET DAY AUTO CLEAR OFF CLOCK ON HR MIN AUTO ON CLEAR OFF SET RESET ON GREEN OFF RED APT - 6S PROGRAM SETTING CLOCK DAY HR MIN CLEAR RESET ON GREEN OFF RED APT - 6S ON OFF SE T SET PROGRAM NUMBER LOAD ON SU MO TU WE TH FR SA SE T SET WEEKDAY ON MO SE T ON SET HOUR MO SE T SET MINUTE LOAD ON MO SE T PROGRAM ENABLE OR DISABLEϡ ϡThe pervious setting will be shown when press CLEAR once again. CONVERT Y TYPE (Flush Mounting) TO N TYPE (Surface Mounting) BATTERY CHANGE ᢲ ᢳ ᢲ ᢳ ᢴ Lithium battery CR2032 + 3 VOLTS CONVERT N TYPE (Surface Mounting) TO Y TYPE (Flush Mounting) ᢲ ᢳ ᢴ ANLY ELECTRONICS CO., LTD. http://www.anly.com.tw ᢵ M-APT6-D-B Printed in Taiwan