Download Catalogue numbers, spare parts and order form

Transcript
Masterpact
Catalogue numbers, spare parts
and order form
Presentation
Functions and characteristics
Dimensions and connection
Electrical diagrams
Installation recommendations
Additional characteristics
6
13
59
87
97
121
Communication bus accessories and Display Modules
128
Retrofit solutions
129
Connection for fixed devices
Connection for drawout devices
129
130
Masterpact NT
131
Connection
Micrologic control unit, communication option
Remote operation
Chassis locking and accessories
Clusters
Circuit breaker locking and accessories
Mechanical interlocking for source changeover
Indication contacts
Instructions
131
132
133
134
135
136
137
138
139
Masterpact NW
140
Connection
Micrologic control unit, communication option
Remote operation
Chassis locking and accessories
Clusters
Circuit breaker locking and accessories
Mechanical interlocking for source changeover
Indication contacts
Instructions
140
141
142
143
144
145
146
147
148
Masterpact NT and NW order form
149
127
see your best prices of Merlin Gerin Air Circuit Breakers (ACB) Masterpact NT & NW and other products at www.cyberallgroup.com/SchneiderElectric
Communication bus accessories
and Display Modules
Catalogue numbers
0
Display modules
DMB300
Max. 4 breakers
50894
Color display module
Max. 16 breakers
50895
E67954
Monochrome display module
E67955
DMC300
Spare parts
50959
E67955
DMC300PCM: DMC300 memory card
RS485 Modbus pre-wired system
RS485 Modbus junction block
50963
CSD309: 9 pins SubD with screw terminals
50964
CDM303: display module pre-wired cable, 3 m length
50960
E67958
CJB306: 6 SubD 9 pins connectors junction block
E67959
RS485 Modbus connector
E67960
RS485 Modbus cables
E79015
CCP303: Masterpact or Compact pre-wired cable (4 RS485 wires + 2 power wires) 3 m length 50961
50965
E67961
CCR301: RS485 roll cable (2 RS485 wires + 2 power wires) 60 m length
External 24 V DC power-supply module
External 24 V DC power-supply module
DB102195
Input
AD
24/30 V DC
48/60 V DC
100/125 V DC
110/130 V AC
200/240 V AC
380/415 V AC
54440
54441
54442
54443
54444
54445
Converter
RS485/RS232 (ACE909) 12 V DC power supply included
RS485/RS232
RS485/Ethernet
RS485/Ethernet (SMS compatible)
59648
TSX SCA72
174 CEV 300-20
EGX 200/400
(1)
(1)
(2)
DB101033
Micro Power Server MPS100
MPS100
33507
(1) See catalogue Telemecanique.
(2) See catalogue PowerLogic System.
128
see your best prices of Merlin Gerin Air Circuit Breakers (ACB) Masterpact NT & NW and other products at www.cyberallgroup.com/SchneiderElectric
Catalogue numbers
To replace a Masterpact M with a
Masterpact NW, order a retrofit device
(without connections) and select a set of
connectors corresponding to the replaced
device.
The Masterpact NW is installed in exactly
the same place as the old Masterpact M
device, without any modifications required
on the switchboard.
Retrofit solutions (*)
Connection for fixed devices
0
Horizontal rear connection
Device to be replaced
Connection to be ordered
Masterpact M08 to M12
Type N1/NI
Top
Bottom
Type H1/H2/HI/HF
Top
Bottom
3P
3 x 48951
3 x 48964
4P
4 x 48951
4 x 48964
3 x 48954
3 x 48965
4 x 48954
4 x 48965
3 x 48954
3 x 48965
4 x 48954
4 x 48965
3 x 48957
3 x 48958
4 x 48957
4 x 48958
Masterpact M16
Type N1/NI/H1/H2/HI/HF
Top
Bottom
Masterpact M20 and M25
Type N1/NI/H1/H2/HI/HF
Top
Bottom
Masterpact M32
Type H1/H2/HI/HF
Top
1 x 48962
Bottom
1 x 48961
(*) Please contact U2R (Retrofit Replacement Unit).
1 x 48960
1 x 48960
129
see your best prices of Merlin Gerin Air Circuit Breakers (ACB) Masterpact NT & NW and other products at www.cyberallgroup.com/SchneiderElectric
Catalogue numbers
To replace a Masterpact M with a
Masterpact NW, order a retrofit device
(without connections) and select a set of
connectors corresponding to the replaced
device.
The Masterpact NW is installed in exactly
the same place as the old Masterpact M
device, without any modifications required
on the switchboard.
Retrofit solutions (*)
Connection for drawout devices
0
Vertical rear connection
Device to be replaced
Connection to be ordered
Masterpact M08 to M12
Type N1/NI
Top
Bottom
Type H1/H2/HI/HF
Top
Bottom
3P
3 x 48966
3 x 48966
4P
4 x 48966
4 x 48966
3 x 48969
3 x 48969
4 x 48969
4 x 48969
3 x 48969
3 x 48969
4 x 48969
4 x 48969
3 x 48970
3 x 48970
4 x 48970
4 x 48970
1 x 48974
1 x 48974
1 x 48978
1 x 48978
Masterpact M16
Type N1/NI/H1/H2/HI/HF
Top
Bottom
Masterpact M20 and M25
Type N1/NI/H1/H2/HI/HF
Top
Bottom
Masterpact M32
Type H1/H2/HI/HF
Top
Bottom
Horizontal rear connection
Device to be replaced
Connection to be ordered
Masterpact M08 to M12
Type N1/NI
Top
Bottom
Type H1/H2/HI/HF
Top
Bottom
3P
3 x 48951
3 x 48964
4P
4 x 48951
4 x 48964
3 x 48954
3 x 48965
4 x 48954
4 x 48965
3 x 48954
3 x 48965
4 x 48954
4 x 48965
3 x 48957
3 x 48958
4 x 48957
4 x 48958
Masterpact M16
Type N1/NI/H1/H2/HI/HF
Top
Bottom
Masterpact M20 and M25
Type N1/NI/H1/H2/HI/HF
Top
Bottom
Masterpact M32 neutral on left-hand side
Type H1/H2/HI/HF
Top
Bottom
1 x 48973
1 x 48973
1 x 48976
1 x 48977
Masterpact M32 neutral on right-hand side
Type H1/H2/HI/HF
Top
1 x 48973
Bottom
1 x 48973
(*) Please contact U2R (Retrofit Replacement Unit)
1 x 48977
1 x 48976
130
see your best prices of Merlin Gerin Air Circuit Breakers (ACB) Masterpact NT & NW and other products at www.cyberallgroup.com/SchneiderElectric
Catalogue numbers:
spare parts
Masterpact NT
Connection
0
(*) Installation manual must be ordered separatly,
it is not supply with the component
Connection
3P
4P
47069
47070
Fixed circuit breakers
630/1600 A
E95534
Front connection / Replacement kit (3 or 4 parts)
Top or bottom
Installation manual
47102
33584
33585
E46430
E46429
Rear connection (vertical or horizontal mounting) / Replacement kit (3 or 4 parts)
630/1600 A
Vert. mounting. Horiz. mounting. Installation manual
47102
Drawout circuit breakers
630/1600 A
33588
33589
E46440
Front connection / Replacement kit (6 or 8 parts)
Top and bottom
Installation manual
47102
33586
33587
E46430
E46429
Rear connection (vertical or horizontal mounting) / Replacement kit (3 or 4 parts)
630/1600 A
Vert. mounting. Horiz. mounting. Installation manual
47102
Connection accessories
3P
4P
For fixed and drawout front-connected circuit breakers
33642
33643
Installation manual
47102
E46426
Vertical connection adapters 630/1600 A / Replacement kit (3 or 4 parts)
E46427
Cable lug adapters 630/1600 A / Replacement kit (3 or 4 parts)
For fixed and drawout front-connected circuit breakers
33644
Installation manual
47102
33645
E46431
Spreaders / Replacement kit (3 or 4 parts)
For fixed and drawout front and rear-connected circuit breakers
33622
Installation manual
47102
33623
E79151
Interphase barriers / Replacement kit (3 or 4 parts)
For fixed and drawout front and rear-connected circuit breakers
For drawout rear-connected circuit breakers
Installation manual
33648
33768
47102
33648
33768
For fixed front-connected circuit breakers
47335
47336
Installation manual
47102
E74437
Arc chute screen (1 part)
131
see your best prices of Merlin Gerin Air Circuit Breakers (ACB) Masterpact NT & NW and other products at www.cyberallgroup.com/SchneiderElectric
Catalogue numbers:
spare parts
Masterpact NT
Micrologic control unit,
communication option
0
(*) Installation manual must be ordered separatly,
it is not supply with the component
Replacement parts for Micrologic control units
Long-time rating plug (limits setting range for higher accuracy) / 1 part
E46674
Standard
Low-setting option
High-setting option
Without long-time protection
Installation manual
0.4 at 1 x Ir
0.4 at 0.8 x Ir
0.8 at 1 x Ir
off
33542
33543
33544
33545
33075
Battery + cover
E95540
Battery (1 part)
Cover (1 part)
For Micrologic A
For Micrologic P and H
33593
33592
47067
menu
Installation manual
33075
Modbus COM
Digipact COM
6 wires terminal drawout (1 part)
6 wires terminal fixed (1 part)
33852
33855
33099
47075
Installation manual
33088
Communication option
E95541
Chassis
External sensors
400/1600 A
33576
E46671
External sensor for earth-fault protection (TCE) / 1 part
Sensor rating
33579
48891
Rectangular sensor for earth-leakage protection + Vigi cable / 1 part
280 mm x 115 mm
33573
E46672
E46671
Source ground return (SGR) earth-fault protection / 1 part
External sensor (SGR)
MDGF summing module
Vigi cable or external voltage cable / 1 part
Vigi cable or external voltage cable (1 part)
47090
E59661
External power supply module / 1 part
24-30 V DC
48-60 V DC
100-125 V DC
110-130 V AC
200-240 V AC
380-415 V AC
54440
54441
54442
54443
54444
54445
24 V DC
54446
Battery module / 1 part
1 battery
E59554
Test equipments / 1 part
Mini test kit
Portable test kit
Wiring kit or mini test kit or portable test kit
2 pin test cable
33594
33595
33590
S48908
(*)
(*) Consult us.
132
see your best prices of Merlin Gerin Air Circuit Breakers (ACB) Masterpact NT & NW and other products at www.cyberallgroup.com/SchneiderElectric
Catalogue numbers:
spare parts
Masterpact NT
Remote operation
0
(*) Installation manual must be ordered separatly,
it is not supply with the component
Remote operation
Gear motor
E95168
MCH (1 part)
AC 50/60 Hz
DC
Fixed.
33186
33176
33177
33179
33179
33193
33185
33186
33187
33188
47074
33098
E95171
E95169
Terminal block (1 part)
48 V
100-130 V
200-240 V
277-415 V
440-480 V
+ resistor
24-30 V
48-60 V
100-125 V
200-250 V
For fixed circuit breaker
For drawout circuit breaker
Drawout.
Installation manual
47103
Closing and opening release (XF or MX)
Fixed.
12 V DC
24-30 V AC/DC
48-60 V AC/DC
100-130 V AC/DC
200-250 V AC/DC
277 V AC
380-480 V AC
Communicating coil (1 part)
AC 50/60 Hz
12 V DC
DC
24-30 V AC/DC
48-60 V AC/DC
100-130 V AC/DC
200-250 V AC/DC
277 V AC
380-480 V AC
Terminal block (1 part)
For fixed circuit breaker
For drawout circuit breaker
33658
33659
33660
33661
33662
33663
33664
33032
33033
33034
33035
33036
33037
33038
47074
33098
Installation manual
47103
Undervoltage release (1 part)
AC 50/60 Hz
24-30 V DC, 24 V AC
DC
48-60 V DC, 48 V AC
100-130 V AC/DC
200-250 V AC/DC
380-480 V AC
Terminal block (1 part)
For fixed circuit breaker
For drawout circuit breaker
33668
33669
33670
33671
33673
47074
33098
Installation manual
47103
E95171
E95169
E95170
Standard coil (1 part)
AC 50/60 Hz
DC
Drawout.
Fixed.
E95171
E95169
E95170
Undervoltage release MN
Drawout.
MN delay unit
E46694
MN delay unit (1 part)
R (non-adjustable)
AC 50/60 Hz
DC
Installation manual
48-60 V
100-130 V
200-250 V
380-480 V
33684
33685
Rr (adjustable)
33680
33681
33682
33683
47103
133
see your best prices of Merlin Gerin Air Circuit Breakers (ACB) Masterpact NT & NW and other products at www.cyberallgroup.com/SchneiderElectric
Catalogue numbers:
spare parts
Masterpact NT
Chassis locking and accessories
0
(*) Installation manual must be ordered separatly,
it is not supply with the component
Chassis locking
"Disconnected" position locking / 1 part
E46685
By padlocks
Standard
By keylocks
Profalux
1 lock
1 lock + 1 lock with same key profile
2 locks (different key profiles)
1 identical keylock Profalux with the same key:
key: random not identified combination
key: random identified 215470 combination
key: random identified 215471 combination
Ronis
1 lock
1 lock + 1 lock with same key profile
2 locks (different key profiles)
1 identical keylock Ronis with the same key :
key: random not identified combination
key: random identified EL24135 combination
key: random identified EL24153 combination
key: random identified EL24315 combination
Locking kit without locks for Profalux
Ronis
Castell
Kirk
Installation manual
33773
33774
33775
Right and left-hand side of chassis (VPECD or VPECG)
33172
Installation manual
47104
Racking interlock (VPOC)
33788
Installation manual
47104
33173
33174
33175
33776
33777
33778
33189
33190
33191
33192
33769
33770
33771
33772
47104
E46464
Door interlock / 1 part
E46465
Racking interlock / 1 part
Breaker mismatch protection / 1 part
33767
Installation manual
47104
E46456
Breaker mismatch protection (VDC)
Chassis accessories
Auxiliary terminal shield (CB) / 1 part
E46698
Terminal shield
3P
4P
Installation manual
33763
33764
47104
Safety shutters + locking / 1 part
E46699
Safety shutters (VO)
3P
4P
Installation manual
Nota : the locking of safety shutters is integrated.
33765
33766
47104
134
see your best prices of Merlin Gerin Air Circuit Breakers (ACB) Masterpact NT & NW and other products at www.cyberallgroup.com/SchneiderElectric
Catalogue numbers:
spare parts
Masterpact NT
Clusters
0
E95538
Clusters
Grease for disconnecting contact clusters (1 kg)
1 disconnecting contact cluster for chassis (see table below) 1 part
54122
33166
Table : number of clusters required for the different chassis models
Chassis rating (A)
630
800
1000
1250
1600
Nota :
Masterpact NT
3P
4P
12
18
12
18
12
18
12
18
18
24
the minimum order is 6 parts.
Racking handle / 1 part
47098
E95561
Racking handle
135
see your best prices of Merlin Gerin Air Circuit Breakers (ACB) Masterpact NT & NW and other products at www.cyberallgroup.com/SchneiderElectric
Catalogue numbers:
spare parts
Masterpact NT
Circuit breaker locking and
accessories
0
(*) Installation manual must be ordered separatly,
it is not supply with the component
Circuit breaker locking
Pushbutton locking device / 1 part
33897
Installation manual
47103
E46666
By padlocks
OFF position locking / 1 part
By padlocks + BPFE support
E46701
47514
By keylocks + BPFE support
Profalux
1 lock
1 lock + 1 lock with same key profile
1 identical keylock Profalux with the same key:
key: random not identified combination
key: random identified 215470 combination
key: random identified 215471 combination
Ronis
1 lock
1 lock + 1 lock with same key profile
1 identical keylock Ronis with the same key :
key: random not identified combination
key: random identified EL24135 combination
key: random identified EL24153 combination
key: random identified EL24315 combination
Locking kit without locks for Profalux
Ronis
Kirk
Castell
Installation manual
47519
47520
33173
33174
33175
47521
47522
33189
33190
33191
33192
47515
47516
47517
47518
47103
Other circuit breaker accessories
Mechanical operation counter / 1 part
33895
Installation manual
47103
E46667
Operation counter CDM
E46670
E46669
E46668
Escutcheon and accessories / 1 part
EscutcheonCoverBlanking plate
Escutcheon
Transparent cover (IP 54)
Escutcheon blanking plate
Fixed
33718
Installation manual
Drawout
33857
33859
33858
47103
Front cover (3P / 4P) / 1 part
47094
Installation manual
47103
E95558
Front cover
Spring charging handle / 1 part
47092
Installation manual
47103
E95559
Spring charging handle
E95560
Arc chute for Masterpact NT / 1 part
Type H1
Type L1
Installation manual
3P
3 x 47095
3 x 47096
4P
4 x 47095
4 x 47096
47103
136
see your best prices of Merlin Gerin Air Circuit Breakers (ACB) Masterpact NT & NW and other products at www.cyberallgroup.com/SchneiderElectric
Catalogue numbers:
spare parts
Masterpact NT
Mechanical interlocking for source
changeover
0
Mechanical interlocking for source changeover
E47760
Interlocking using connecting rods
Complete assembly with 2 adaptation fixtures + rods
2 Masterpact NT fixed devices
2 Masterpact NT drawout devices
Nota : the installation manual is enclosed.
33912
33913
Choose 2 adaptation fixtures (1 for each breaker) + 1 set of cables
1 adaptation fixture for Masterpact NT fixed devices
1 adaptation fixture for Masterpact NT drawout devices
1 set of 2 cables
(1) Can be used with any combination of NT or NW, fixed or drawout devices.
33200
33201
33209
Interlocking using cables (1)
E70742
Cable-type door interlock
1 complete assembly for Masterpact NT fixed devices
1 complete assembly for Masterpact NT drawout devices
Nota : the installation manual is enclosed.
33920
33921
137
see your best prices of Merlin Gerin Air Circuit Breakers (ACB) Masterpact NT & NW and other products at www.cyberallgroup.com/SchneiderElectric
Catalogue numbers:
spare parts
Masterpact NT
Indication contacts
0
(*) Installation manual must be ordered separatly,
it is not supply with the component
Indication contacts
E46463
ON/OFF indication contacts (OF) / 1 part
Changeover contacts (6 A - 240 V)
1 low-level OF to replace 1 standard OF (4 max.)
Wiring
For fixed circuit breaker
For drawout circuit breaker
Installation manual
47076
47077
47074
33098
47103
E47758
"Fault trip" indication contacts (SDE) / 1 part
1 additional SDE (5 A - 240 V)
1 additional low-level SDE
Wiring
For fixed circuit breaker
For drawout circuit breaker
Installation manual
47078
47079
47074
33098
47103
E46664
"Ready to close" contact (1 max.) / 1 part
1 changeover contact (5 A - 240 V)
1 low-level changeover contact
Wiring
For fixed circuit breaker
For drawout circuit breaker
Installation manual
PF
47080
47081
47074
33098
47103
E46439
Electrical closing pushbutton / 1 part
1 pushbutton
BPFE
47512
Installation manual
47103
E46661
Carriage switches (connected / disconnected / test position) / 1 part
Changeover contacts (6A - 240 V)
1 connected position contact (3 max.)
1 test position contact (1 max.)
1 disconnected position contact (2 max.)
And/or low-level changeover contacts
1 connected position contact (3 max.)
1 test position contact (1 max.)
1 disconnected position contact (2 max.)
33170
33170
33170
33171
33171
33171
E95171
Auxiliary terminals for chassis alone
3 wire terminal (1 part), terminal block (1 part)
Jumpers (10 parts)
Installation manual
33098
47900
47104
138
see your best prices of Merlin Gerin Air Circuit Breakers (ACB) Masterpact NT & NW and other products at www.cyberallgroup.com/SchneiderElectric
Catalogue numbers:
spare parts
Masterpact NT
Instructions
0
(*) Installation manual must be ordered separatly,
it is not supply with the component
Instructions
Chassis accessories
Circuit breaker accessories
Fixed and drawout circuit breaker
Micrologic user manual
20 / 50 (French)
20 / 50 (English)
2A / 7A (French)
2A / 7A (English)
5P / 7P (French)
5P / 7P (English)
5H / 7H (French)
5H / 7H (English)
NT user manual
French
English
Modbus communication notice for manual
Micrologic accessories replacement guide
47104
47103
47102
33076
33077
33079
33080
33082
33083
33085
33086
47106
47107
33088
33075
139
see your best prices of Merlin Gerin Air Circuit Breakers (ACB) Masterpact NT & NW and other products at www.cyberallgroup.com/SchneiderElectric
Catalogue numbers:
spare parts
Masterpact NW
Connection
0
(*) Installation manual must be ordered separatly,
it is not supply with the component
Connection
3P
4P
Top
Top
47990
47992
47991
47993
Bottom
Bottom
47932
47942
47933
47943
Fixed circuit breakers
E95533
E95557
Front connection / Replacement kit (3 or 4 parts)
800/1600 A
2000/3200 A
800/1600 A
2000/3200 A
E46446
E46445
Installation manual
Rear connection (vertical or horizontal mounting) / Replacement kit (3 or 4 parts)
800/2000 A
Vertical
Horizontal
2500/3200 A
Vertical
Horizontal
Vertical mounting
4000 A
Vertical
Horizontal
4000b/5000 A
Vertical
Horizontal
Horizontal mounting
6300 A
Vertical
Installation manual
47950
47964
47964
47966
47966
47968
47970
2x 47966
2x 47966
2x 47968
47950
47965
47965
47967
47967
47969
47971
2x 47967
2x 47967
2x 47969
47960
47962
47961
47963
Drawout circuit breakers
E46450
Front connection / Replacement kit (3 or 4 parts)
800/1600 A
2000/3200 A
Top or bottom
Top or bottom
Installation manual
Rear connection (vertical or horizontal mounting) / Replacement kit (3 or 4 parts)
800/2000 A types N1/H1/H2 Vertical
800/1600 A types H3/L1
Horizontal
2500/3200 A types H1/H2
Vertical
2000/3200 A types H3/L1
Horizontal
Vertical mounting
4000 A
Vertical
Horizontal
4000b/5000 A
Vertical
Horizontal
Horizontal mounting
6300 A
Vertical
Installation manual
47950
47965
47965
47967
47967
47969
47971
2x 47967
2x 47967
2x 47969
3P
4P
1600 A
2000/3200 A
48464
48465
48466
48467
Installation manual
47950
E46446
E46445
47964
47964
47966
47966
47968
47970
2x 47966
2x 47966
2x 47968
47950
Connection accessories
E46889
Disconnectable front-connection adapter for fixed circuit breaker (3 or 4 parts)
E46428
Interphase barriers / Replacement kit (3 parts)
For fixed rear-connected circuit breaker
For drawout rear-connected circuit breaker
48599
48600
Installation manual
47950
48599
48600
140
see your best prices of Merlin Gerin Air Circuit Breakers (ACB) Masterpact NT & NW and other products at www.cyberallgroup.com/SchneiderElectric
Catalogue numbers:
spare parts
Masterpact NW
Micrologic control unit,
communication option
0
(*) Installation manual must be ordered separatly,
it is not supply with the component
Replacement parts for Micrologic control units
Long-time rating plug (limits setting range for higher accuracy) / 1 part
E46674
Standard
Low-setting option
High-setting option
Without long-time protection
Installation manual
0.4 at 1 x Ir
0.4 at 0.8 x Ir
0.8 at 1 x Ir
off
33542
33543
33544
33545
33075
Battery + cover
E95540
Battery (1 part)
Cover (1 part)
For Micrologic A
For Micrologic P and H
33593
33592
47067
menu
Installation manual
33075
Modbus COM
Digipact COM
6 wires terminal drawout (1 part)
6 wires terminal fixed (1 part)
33852
33855
47850
47075
Installation manual
33088
Communication option
E95541
Chassis
External sensors
E46671
External sensor for earth-fault protection (TCE) / 1 part
Sensor rating
400/2000 A
1000/4000 A
4000/6300 A
34035
34036
48182
33579
48891
Rectangular sensor for earth-leakage protection + Vigi cable / 1 part
280 mm x 115 mm
470 mm x 160 mm
33573
33574
E46672
E46671
Source ground return (SGR) earth-fault protection / 1 part
External sensor (SGR)
MDGF summing module
Vigi cable or external voltage cable / 1 part
Vigi cable or external voltage cable
47090
E59661
External power supply module / 1 part
24-30 V DC
48-60 V DC
100-125 V DC
110-130 V AC
200-240 V AC
380-415 V AC
54440
54441
54442
54443
54444
54445
24 V DC
54446
Battery module / 1 part
1 battery
E59554
Test equipments / 1 part
Mini test kit
Portable test kit
Wiring kit or mini test kit or portable test kit
2 pin test cable
33594
33595
33590
S48908
(*)
(*) Consult us.
141
see your best prices of Merlin Gerin Air Circuit Breakers (ACB) Masterpact NT & NW and other products at www.cyberallgroup.com/SchneiderElectric
Catalogue numbers:
spare parts
Masterpact NW
Remote operation
0
(*) Installation manual must be ordered separatly,
it is not supply with the component
Remote operation
Gear motor
E95172
MCH (1 part)
AC 50/60 Hz
E95171
E95169
DC
Terminal block (1 part)
Fixed.
48 V
100-130 V
200-240 V
250-277 V
380-415 V
440-480 V
24-30 V
48-60 V
100-125 V
200-250 V
For fixed circuit breaker
For drawout circuit breaker
47889
47893
47894
47895
47896
47897
47888
47889
47890
47891
47074
47849
Drawout.
Installation manual
47951
Closing and opening release (XF or MX)
Fixed.
E95171
E95169
E95170
Standard coil (1 part)
AC 50/60 Hz
DC
12 V DC
24-30 V AC/DC
48-60 V AC/DC
100-130 V AC/DC
200-250 V AC/DC
277 V AC
380-480 V AC
Communicating coil (1 part)
AC 50/60 Hz
12 V DC
DC
24-30 V AC/DC
48-60 V AC/DC
100-130 V AC/DC
200-250 V AC/DC
277 V AC
380-480 V AC
Terminal block (1 part)
For fixed circuit breaker
For drawout circuit breaker
33658
33659
33660
33661
33662
33663
33664
33032
33033
33034
33035
33036
33037
33038
47074
47849
Installation manual
47951
Undervoltage release (1 part)
AC 50/60 Hz
24-30 V DC, 24 V AC
DC
48-60 V DC, 48 V AC
100-130 V AC/DC
200-250 V AC/DC
380-480 V AC
Terminal block (1 part)
For fixed circuit breaker
For drawout circuit breaker
33668
33669
33670
33671
33673
47074
47849
Installation manual
47951
Drawout.
Fixed.
E95171
E95169
E95170
Undervoltage release MN
Drawout.
MN delay unit
E46694
MN delay unit (1 part)
R (non-adjustable)
AC 50/60 Hz
DC
Installation manual
48-60 V
100-130 V
200-250 V
380-480 V
33684
33685
Rr (adjustable)
33680
33681
33682
33683
47951
142
see your best prices of Merlin Gerin Air Circuit Breakers (ACB) Masterpact NT & NW and other products at www.cyberallgroup.com/SchneiderElectric
Catalogue numbers:
spare parts
Masterpact NW
Chassis locking and accessories
0
(*) Installation manual must be ordered separatly,
it is not supply with the component
Chassis locking
"Disconnected" position locking / 1 part
E46451
By padlocks
Standard
By keylocks
Profalux
1 lock
1 lock + 1 lock with same key profile
2 locks (different key profiles)
1 identical keylock Profalux with the same key:
key: random not identified combination
key: random identified 215470 combination
key: random identified 215471 combination
Ronis
1 lock
1 lock + 1 lock with same key profile
2 locks (different key profiles)
1 identical keylock Ronis with the same key :
key: random not identified combination
key: random identified EL24135 combination
key: random identified EL24153 combination
key: random identified EL24315 combination
Locking kit without locks for Profalux, Ronis
Castell
Kirk
Installation manual
48568
48569
48570
Right and left-hand side of chassis (VPECD or VPECG)
47914
Installation manual
47952
5 parts
48582
Installation manual
47952
33173
33174
33175
48572
48573
48574
33189
33190
33191
33192
48564
48565
48566
47952
E46452
Door interlock / 1 part
E46453
Racking interlock
Breaker mismatch protection / 1 part
33767
Installation manual
47952
E46456
Breaker mismatch protection (VDC)
Chassis accessories
Auxiliary terminal shield (CB) / 1 part
E46458
800/4000 A
4000b/6300 A
3P
4P
3P
4P
48595
48596
48597
48598
47952
3P
4P
3P
4P
48721
48723
48722
48724
47952
Installation manual
Safety shutters + locking block / 1 part
E46459
800/4000 A
4000b/6300 A
Installation manual
E46460
Shutter locking block (for replacement) / 1 part
2 parts for 800/4000 A
48591
Installation manual
47952
Earthing kit for chassis
3P
4P
48433
48434
Types for N1/H1/NA/HA
Nota : the installation manual is enclosed.
143
see your best prices of Merlin Gerin Air Circuit Breakers (ACB) Masterpact NT & NW and other products at www.cyberallgroup.com/SchneiderElectric
Catalogue numbers:
spare parts
Masterpact NW
Clusters
0
(*) Installation manual must be ordered separatly,
it is not supply with the component
E95538
Clusters
Grease for disconnecting contact clusters (1 kg)
1 disconnecting contact cluster for chassis (see table below) (part 1)
54122
33166
Table : number of clusters required for the different chassis models
Chassis rating (A)
Masterpact NW 3P
N1
H1/H2 H3
630
800
6
12
1000
6
12
1250
6
12
1600
12
12
2000
24
2500
24
3200
36
4000
42
4000b
72
5000
72
6300
72
Nota : the minimum order is 6 parts.
24
24
36
42
L1
24
24
24
24
42
Masterpact NW 4P
N1
H1/H2 H3
8
8
8
16
16
16
16
16
32
32
48
56
96
96
96
32
32
48
56
L1
32
32
32
32
56
Racking handle
47944
E95561
Racking handle
144
see your best prices of Merlin Gerin Air Circuit Breakers (ACB) Masterpact NT & NW and other products at www.cyberallgroup.com/SchneiderElectric
Catalogue numbers:
spare parts
Masterpact NW
Circuit breaker locking and
accessories
0
(*) Installation manual must be ordered separatly,
it is not supply with the component
Circuit breaker locking
Pushbutton locking device / 1 part
48536
Installation manual
47951
E46666
By padlocks
OFF position locking / 1 part
By padlocks / 1 part
E46735
48539
By padlocks and keylocks / 1 part
Profalux
1 lock
1 lock + 1 lock with same key profile
2 locks (different key profiles)
1 identical keylock Profalux with the same key:
key: random not identified combination
key: random identified 215470 combination
key: random identified 215471 combination
Ronis
1 lock
1 lock + 1 lock with same key profile
2 locks (different key profiles)
1 identical keylock Ronis with the same key :
key: random not identified combination
key: random identified EL24135 combination
key: random identified EL24153 combination
key: random identified EL24315 combination
Locking kit without locks for Profalux, Ronis
Kirk
Castell
Installation manual
48545
48546
48547
33173
33174
33175
48549
48550
48551
33189
33190
33191
33192
48541
48542
48543
47951
Other circuit breaker accessories
Mechanical operation counter / 1 part
48535
Installation manual
47951
E46667
Operation counter CDM
Escutcheon
Cover
Fixed
48601
Escutcheon
Transparent cover (IP 54)
Escutcheon blanking plate
E46670
E46669
E46668
Escutcheon and accessories / 1 part
Blanking plate
Drawout
48603
48604
48605
48605
Installation manual
47951
Front cover (3P / 4P) / 1 part
47939
Installation manual
47951
E95535
Front cover
Spring charging handle / 1 part
47940
Installation manual
47951
E95536
Spring charging handle
E95537
Arc chute for Masterpact NW / 1 part
Type N1
Type H1/H2 (NW08 to NW40)
Type H1/H2 (NW40b to NW63)
Type H3
Type L1
Type NW DC
Installation manual
3x
3x
6x
3x
3x
3x
3P
47935
47935
47936
47936
47937
47934
4x
4x
8x
4x
4x
4x
4P
47935
47935
47936
47936
47937
47934
47951
145
see your best prices of Merlin Gerin Air Circuit Breakers (ACB) Masterpact NT & NW and other products at www.cyberallgroup.com/SchneiderElectric
Catalogue numbers:
spare parts
Masterpact NW
Mechanical interlocking for source
changeover
0
(*) Installation manual must be ordered separatly,
it is not supply with the component
Mechanical interlocking for source changeover
E47762
Interlocking of 2 devices using connecting rods
Complete assembly with 2 adaptation fixtures + rods
2 Masterpact NW fixed devices
2 Masterpact NW drawout devices
Can be used with 1 NW fixed + 1 NW drawout.
Nota : the installation manual is enclosed.
48612
48612
Interlocking of 2 devices using cables (1)
Choose 2 adaptation sets (1 for each device + 1 set of cables)
1 adaptation fixture for Masterpact NW fixed devices
1 adaptation fixture for Masterpact NW drawout devices
1 set of 2 cables
(1) Can be used with any combination of NT or NW, fixed or drawout devices.
47926
47926
33209
Interlocking of 3 devices using cables
Choose 3 adaptation (inclusing 3 adaptation fixtures + cables)
3 sources, only 1 device closed, fixed or drawout devices
2 sources + 1 coupling, fixed or drawout devices
2 normal + 1 replacement source, fixed or drawout devices
48610
48609
48608
Cable-type door interlock
1 complete assembly for Masterpact NW fixed or drawout device
Nota : the installation manual is enclosed.
48614
146
see your best prices of Merlin Gerin Air Circuit Breakers (ACB) Masterpact NT & NW and other products at www.cyberallgroup.com/SchneiderElectric
Catalogue numbers:
spare parts
Masterpact NW
Indication contacts
0
(*) Installation manual must be ordered separatly,
it is not supply with the component
Indication contacts
E46689
ON/OFF indication contacts (OF) / 1 part
1 additional block of 4 contacts
Wiring
For fixed circuit breaker
For drawout circuit breaker
47887
47074
47849
Installation manual
47951
"Fault trip" indication contacts (SDE) / 1 part
E46691
Changeover contact (SDE)
Wiring
6 A - 240 V
Low-level
For fixed circuit breaker
For drawout circuit breaker
Installation manual
47915
47916
47074
47849
47951
E46438
"Ready to close" contact (1 max.) / 1 part
1 changeover contact (5 A - 240 V)
1 low-level changeover contact
Wiring
For fixed circuit breaker
For drawout circuit breaker
Installation manual
PF
47080
47081
47074
47849
47951
E46661
"Connected, disconnected, test position" indication contact (carriage switches) / 1 part
Changeover contacts
CE, CD, CT
6 A - 240 V
Low-level
Installation manual
33170
33171
47952
Set of additional actuaters for carriage switches / 1 set
1 set
48560
E46690
Combined closed / connected contacts for use with 1 auxiliary contact / 1 part
1 contact (5 A - 240 V)
or 1 low-level contact
48477
48478
Installation manual
47952
E46677
Electrical closing pushbutton / 1 part
1 pushbutton
BPFE
48534
Installation manual
47951
Auxiliary terminals for chassis alone
3 wire terminal (1 part)
6 wire terminal (1 part)
Jumpers (10 parts)
47849
47850
47900
147
see your best prices of Merlin Gerin Air Circuit Breakers (ACB) Masterpact NT & NW and other products at www.cyberallgroup.com/SchneiderElectric
Catalogue numbers:
spare parts
Masterpact NW
Instructions
0
Instructions
Chassis accessories
Circuit breaker accessories
Fixed and drawout circuit breaker
User manual
NW AC (French)
NW AC (English)
NW DC (French)
NW DC (English)
Micrologic user manual
20 / 50 (French)
20 / 50 (English)
2A / 7A (French)
2A / 7A (English)
5P / 7P (French)
5P / 7P (English)
5H / 7H (French)
5H / 7H (English)
Modbus communication notice for manual
Micrologic accessories replacement guide
47952
47951
47950
47954
47955
47957
47958
33076
33077
33079
33080
33082
33083
33085
33086
33088
33075
148
see your best prices of Merlin Gerin Air Circuit Breakers (ACB) Masterpact NT & NW and other products at www.cyberallgroup.com/SchneiderElectric
Masterpact NT and NW order form
Order form
To indicate your choice, check the applicable square boxes
Indication contacts
OF - ON/OFF indication contacts
Standard
4 OF 6 A-240 V AC (10 A-240 V AC and low-level for NW)
Alternate
1 OF low-level for NT
Max. 4
qty
and enter the appropriate information in the rectangles
Additional
Circuit breaker
or switch-disconnector
Masterpact type
NT
Rating
A
Sensor rating
A
Circuit breaker
Special circuit breaker
Quantity
1 block of 4 OF for NW
Max. 2
EF - combined "connected/closed" contacts
1 EF 6 A-240 V AC for NW
NW
1 EF low-level for NW
qty
Max. 8
qty
Max. 8
qty
N1, H1, H2, H3, L1
SDE - "fault-trip" indication contact
Standard
1 SDE 6 A-240 V AC
Additional
1 SDE 6 A-240 V AC
1 SDE low level
H2 anticorrosion, H10
Programmable contacts
2 M2C contacts
6 M6C contacts
Switch-disconnector
NA, HA, HF, HA10, ES
Carriage switches
Low level
6 A-240 V AC
Number of poles
3 or 4
CE - "connected" position
Max. 3 for NW/NT
qty
Brand
MG
CD - "disconnected" position
Max. 3 for NW - 2 for NT
qty
CT - "test" position
Max. 3 for NW - 1 for NT
qty
SD
Option: neutral on right side
Type of equipment
AC - NW actuator for 6 CE - 3 CD - 0 CT additional carriage switches
Fixed
Remote ON/OFF
Drawout without chassis
(moving part only)
Chassis alone
MCH - gear motor
V
XF - closing voltage release
V
MX - opening voltage release
Earthing switch kit for chassis
V
PF - "ready to close" contact
Low level
Micrologic control unit
6 A-240 V AC
2.0
5.0
6.0
7.0
BPFE - electrical closing pushbutton
P - power meter
5.0
6.0
7.0
Res - electrical reset option
H - harmonic meter
5.0
6.0
7.0
RAR - automatic reset option
LR - long-time rating plug
qty
Remote operation
Drawout with chassis
A - ammeter
0
Standard 0.4 to 1 Ir
Remote tripping
MN - undervoltage release
Low setting 0.4 to 0.8 Ir
R - delay unit (non-adjustable)
High setting 0.8 to 1 Ir
Res - adjustable delay unit
LR OFF
2nd MX - shunt release
AD - external power-supply module
V
V
V
V
Locking
BAT - battery module
VBP - ON/OFF pushbutton locking (by transparent cover + padlocks)
TCE - external sensor (CT) for neutral
and residual earth-fault protection
TCE - external sensor (CT) for over sized neutral
(3P - Micrologic P / H) and residual earth-fault protection
OFF position locking:
VCPO - by padlocks
VSPO - by keylocks
TCW - external sensor for SGR protection
Rectangular sensor
for earth-leakage protection
NT (280 x 115 mm)
NW (470 x 160 mm)
PTE - external voltage connector
Communication
COM module
JBus/
ModBus
Digipact
Device
Chassis
Eco COM
module
ModBus
(for XF or MX communicating release)
Device
Chassis
Connection
Keyock kit (w/o keylock)
Profalux
Ronis
1 keylock
Profalux
Ronis
2 identical keylocks, 1 key
Profalux
Ronis
2 keylocks, different keys (NW) Profalux
Ronis
Chassis locking in "disconnected" position:
VSPD - by keylocks
Keyock kit (w/o keylock)
Profalux
Castell
1 keylock
Profalux
Ronis
2 identical keylocks, 1 key
Profalux
Ronis
2 keylocks, different keys
Profalux
Ronis
Optional connected/disconnected/test position lock
VPEC - door interlock
On right-hand side chassis
Horizontal
Top
Bottom
Vertical
Top
Bottom
VPOC - racking interlock
Front
Top
Bottom
IPA - cable-type door interlock
Vertical-connection adapters
NT - FC fixed, draw.
VDC - mismatch protection
Cable-lug adapters
NT - FC fixed, draw.
VIVC - shutter position indication and locking for NW
Arc chute screen
NT - FC fixed
IBPO - racking interlock between crank and OFF pushbutton for NW
Interphase barriers
NT, NW fixed, drawout
DAE - automatic spring discharge before breaker removal for NW
Spreaders
NT fixed, drawout
Disconnectable
front connection adapter
Lugs for 240v or 300v cables
NW fixed
NT fixed, drawout
Micrologic control unit functions:
2.0 : basic protection (long time + inst.)
5.0 : selective protection (long time + short time + inst.)
6.0 : selective + earth-fault protection
(long time + short time + inst. + earth-fault)
7.0 : selective + earth-leakage protection
(long time + short time + inst. + earth-leakage)
Ronis
Kirk
On left-hand side chassis
Accessories
VO - safety shutters on chassis for NT and NW
CDM - mechanical operation counter NT, NW
CB - auxiliary terminal shield for chassis NT, NW
CC - arc chute cover for fixed NT
CDP - escutcheon NT, NW
CP - transparent cover for escutcheon NT, NW
OP - blanking plate for escutcheon NT, NW
Brackets for mounting
NW fixed
On backplates
Test kits
Mini test kit
Portable test kit
see your best prices of Merlin Gerin Air Circuit Breakers (ACB) Masterpact NT & NW and other products at www.cyberallgroup.com/SchneiderElectric