Download Catalogue numbers, spare parts and order form
Transcript
Masterpact Catalogue numbers, spare parts and order form Presentation Functions and characteristics Dimensions and connection Electrical diagrams Installation recommendations Additional characteristics 6 13 59 87 97 121 Communication bus accessories and Display Modules 128 Retrofit solutions 129 Connection for fixed devices Connection for drawout devices 129 130 Masterpact NT 131 Connection Micrologic control unit, communication option Remote operation Chassis locking and accessories Clusters Circuit breaker locking and accessories Mechanical interlocking for source changeover Indication contacts Instructions 131 132 133 134 135 136 137 138 139 Masterpact NW 140 Connection Micrologic control unit, communication option Remote operation Chassis locking and accessories Clusters Circuit breaker locking and accessories Mechanical interlocking for source changeover Indication contacts Instructions 140 141 142 143 144 145 146 147 148 Masterpact NT and NW order form 149 127 see your best prices of Merlin Gerin Air Circuit Breakers (ACB) Masterpact NT & NW and other products at www.cyberallgroup.com/SchneiderElectric Communication bus accessories and Display Modules Catalogue numbers 0 Display modules DMB300 Max. 4 breakers 50894 Color display module Max. 16 breakers 50895 E67954 Monochrome display module E67955 DMC300 Spare parts 50959 E67955 DMC300PCM: DMC300 memory card RS485 Modbus pre-wired system RS485 Modbus junction block 50963 CSD309: 9 pins SubD with screw terminals 50964 CDM303: display module pre-wired cable, 3 m length 50960 E67958 CJB306: 6 SubD 9 pins connectors junction block E67959 RS485 Modbus connector E67960 RS485 Modbus cables E79015 CCP303: Masterpact or Compact pre-wired cable (4 RS485 wires + 2 power wires) 3 m length 50961 50965 E67961 CCR301: RS485 roll cable (2 RS485 wires + 2 power wires) 60 m length External 24 V DC power-supply module External 24 V DC power-supply module DB102195 Input AD 24/30 V DC 48/60 V DC 100/125 V DC 110/130 V AC 200/240 V AC 380/415 V AC 54440 54441 54442 54443 54444 54445 Converter RS485/RS232 (ACE909) 12 V DC power supply included RS485/RS232 RS485/Ethernet RS485/Ethernet (SMS compatible) 59648 TSX SCA72 174 CEV 300-20 EGX 200/400 (1) (1) (2) DB101033 Micro Power Server MPS100 MPS100 33507 (1) See catalogue Telemecanique. (2) See catalogue PowerLogic System. 128 see your best prices of Merlin Gerin Air Circuit Breakers (ACB) Masterpact NT & NW and other products at www.cyberallgroup.com/SchneiderElectric Catalogue numbers To replace a Masterpact M with a Masterpact NW, order a retrofit device (without connections) and select a set of connectors corresponding to the replaced device. The Masterpact NW is installed in exactly the same place as the old Masterpact M device, without any modifications required on the switchboard. Retrofit solutions (*) Connection for fixed devices 0 Horizontal rear connection Device to be replaced Connection to be ordered Masterpact M08 to M12 Type N1/NI Top Bottom Type H1/H2/HI/HF Top Bottom 3P 3 x 48951 3 x 48964 4P 4 x 48951 4 x 48964 3 x 48954 3 x 48965 4 x 48954 4 x 48965 3 x 48954 3 x 48965 4 x 48954 4 x 48965 3 x 48957 3 x 48958 4 x 48957 4 x 48958 Masterpact M16 Type N1/NI/H1/H2/HI/HF Top Bottom Masterpact M20 and M25 Type N1/NI/H1/H2/HI/HF Top Bottom Masterpact M32 Type H1/H2/HI/HF Top 1 x 48962 Bottom 1 x 48961 (*) Please contact U2R (Retrofit Replacement Unit). 1 x 48960 1 x 48960 129 see your best prices of Merlin Gerin Air Circuit Breakers (ACB) Masterpact NT & NW and other products at www.cyberallgroup.com/SchneiderElectric Catalogue numbers To replace a Masterpact M with a Masterpact NW, order a retrofit device (without connections) and select a set of connectors corresponding to the replaced device. The Masterpact NW is installed in exactly the same place as the old Masterpact M device, without any modifications required on the switchboard. Retrofit solutions (*) Connection for drawout devices 0 Vertical rear connection Device to be replaced Connection to be ordered Masterpact M08 to M12 Type N1/NI Top Bottom Type H1/H2/HI/HF Top Bottom 3P 3 x 48966 3 x 48966 4P 4 x 48966 4 x 48966 3 x 48969 3 x 48969 4 x 48969 4 x 48969 3 x 48969 3 x 48969 4 x 48969 4 x 48969 3 x 48970 3 x 48970 4 x 48970 4 x 48970 1 x 48974 1 x 48974 1 x 48978 1 x 48978 Masterpact M16 Type N1/NI/H1/H2/HI/HF Top Bottom Masterpact M20 and M25 Type N1/NI/H1/H2/HI/HF Top Bottom Masterpact M32 Type H1/H2/HI/HF Top Bottom Horizontal rear connection Device to be replaced Connection to be ordered Masterpact M08 to M12 Type N1/NI Top Bottom Type H1/H2/HI/HF Top Bottom 3P 3 x 48951 3 x 48964 4P 4 x 48951 4 x 48964 3 x 48954 3 x 48965 4 x 48954 4 x 48965 3 x 48954 3 x 48965 4 x 48954 4 x 48965 3 x 48957 3 x 48958 4 x 48957 4 x 48958 Masterpact M16 Type N1/NI/H1/H2/HI/HF Top Bottom Masterpact M20 and M25 Type N1/NI/H1/H2/HI/HF Top Bottom Masterpact M32 neutral on left-hand side Type H1/H2/HI/HF Top Bottom 1 x 48973 1 x 48973 1 x 48976 1 x 48977 Masterpact M32 neutral on right-hand side Type H1/H2/HI/HF Top 1 x 48973 Bottom 1 x 48973 (*) Please contact U2R (Retrofit Replacement Unit) 1 x 48977 1 x 48976 130 see your best prices of Merlin Gerin Air Circuit Breakers (ACB) Masterpact NT & NW and other products at www.cyberallgroup.com/SchneiderElectric Catalogue numbers: spare parts Masterpact NT Connection 0 (*) Installation manual must be ordered separatly, it is not supply with the component Connection 3P 4P 47069 47070 Fixed circuit breakers 630/1600 A E95534 Front connection / Replacement kit (3 or 4 parts) Top or bottom Installation manual 47102 33584 33585 E46430 E46429 Rear connection (vertical or horizontal mounting) / Replacement kit (3 or 4 parts) 630/1600 A Vert. mounting. Horiz. mounting. Installation manual 47102 Drawout circuit breakers 630/1600 A 33588 33589 E46440 Front connection / Replacement kit (6 or 8 parts) Top and bottom Installation manual 47102 33586 33587 E46430 E46429 Rear connection (vertical or horizontal mounting) / Replacement kit (3 or 4 parts) 630/1600 A Vert. mounting. Horiz. mounting. Installation manual 47102 Connection accessories 3P 4P For fixed and drawout front-connected circuit breakers 33642 33643 Installation manual 47102 E46426 Vertical connection adapters 630/1600 A / Replacement kit (3 or 4 parts) E46427 Cable lug adapters 630/1600 A / Replacement kit (3 or 4 parts) For fixed and drawout front-connected circuit breakers 33644 Installation manual 47102 33645 E46431 Spreaders / Replacement kit (3 or 4 parts) For fixed and drawout front and rear-connected circuit breakers 33622 Installation manual 47102 33623 E79151 Interphase barriers / Replacement kit (3 or 4 parts) For fixed and drawout front and rear-connected circuit breakers For drawout rear-connected circuit breakers Installation manual 33648 33768 47102 33648 33768 For fixed front-connected circuit breakers 47335 47336 Installation manual 47102 E74437 Arc chute screen (1 part) 131 see your best prices of Merlin Gerin Air Circuit Breakers (ACB) Masterpact NT & NW and other products at www.cyberallgroup.com/SchneiderElectric Catalogue numbers: spare parts Masterpact NT Micrologic control unit, communication option 0 (*) Installation manual must be ordered separatly, it is not supply with the component Replacement parts for Micrologic control units Long-time rating plug (limits setting range for higher accuracy) / 1 part E46674 Standard Low-setting option High-setting option Without long-time protection Installation manual 0.4 at 1 x Ir 0.4 at 0.8 x Ir 0.8 at 1 x Ir off 33542 33543 33544 33545 33075 Battery + cover E95540 Battery (1 part) Cover (1 part) For Micrologic A For Micrologic P and H 33593 33592 47067 menu Installation manual 33075 Modbus COM Digipact COM 6 wires terminal drawout (1 part) 6 wires terminal fixed (1 part) 33852 33855 33099 47075 Installation manual 33088 Communication option E95541 Chassis External sensors 400/1600 A 33576 E46671 External sensor for earth-fault protection (TCE) / 1 part Sensor rating 33579 48891 Rectangular sensor for earth-leakage protection + Vigi cable / 1 part 280 mm x 115 mm 33573 E46672 E46671 Source ground return (SGR) earth-fault protection / 1 part External sensor (SGR) MDGF summing module Vigi cable or external voltage cable / 1 part Vigi cable or external voltage cable (1 part) 47090 E59661 External power supply module / 1 part 24-30 V DC 48-60 V DC 100-125 V DC 110-130 V AC 200-240 V AC 380-415 V AC 54440 54441 54442 54443 54444 54445 24 V DC 54446 Battery module / 1 part 1 battery E59554 Test equipments / 1 part Mini test kit Portable test kit Wiring kit or mini test kit or portable test kit 2 pin test cable 33594 33595 33590 S48908 (*) (*) Consult us. 132 see your best prices of Merlin Gerin Air Circuit Breakers (ACB) Masterpact NT & NW and other products at www.cyberallgroup.com/SchneiderElectric Catalogue numbers: spare parts Masterpact NT Remote operation 0 (*) Installation manual must be ordered separatly, it is not supply with the component Remote operation Gear motor E95168 MCH (1 part) AC 50/60 Hz DC Fixed. 33186 33176 33177 33179 33179 33193 33185 33186 33187 33188 47074 33098 E95171 E95169 Terminal block (1 part) 48 V 100-130 V 200-240 V 277-415 V 440-480 V + resistor 24-30 V 48-60 V 100-125 V 200-250 V For fixed circuit breaker For drawout circuit breaker Drawout. Installation manual 47103 Closing and opening release (XF or MX) Fixed. 12 V DC 24-30 V AC/DC 48-60 V AC/DC 100-130 V AC/DC 200-250 V AC/DC 277 V AC 380-480 V AC Communicating coil (1 part) AC 50/60 Hz 12 V DC DC 24-30 V AC/DC 48-60 V AC/DC 100-130 V AC/DC 200-250 V AC/DC 277 V AC 380-480 V AC Terminal block (1 part) For fixed circuit breaker For drawout circuit breaker 33658 33659 33660 33661 33662 33663 33664 33032 33033 33034 33035 33036 33037 33038 47074 33098 Installation manual 47103 Undervoltage release (1 part) AC 50/60 Hz 24-30 V DC, 24 V AC DC 48-60 V DC, 48 V AC 100-130 V AC/DC 200-250 V AC/DC 380-480 V AC Terminal block (1 part) For fixed circuit breaker For drawout circuit breaker 33668 33669 33670 33671 33673 47074 33098 Installation manual 47103 E95171 E95169 E95170 Standard coil (1 part) AC 50/60 Hz DC Drawout. Fixed. E95171 E95169 E95170 Undervoltage release MN Drawout. MN delay unit E46694 MN delay unit (1 part) R (non-adjustable) AC 50/60 Hz DC Installation manual 48-60 V 100-130 V 200-250 V 380-480 V 33684 33685 Rr (adjustable) 33680 33681 33682 33683 47103 133 see your best prices of Merlin Gerin Air Circuit Breakers (ACB) Masterpact NT & NW and other products at www.cyberallgroup.com/SchneiderElectric Catalogue numbers: spare parts Masterpact NT Chassis locking and accessories 0 (*) Installation manual must be ordered separatly, it is not supply with the component Chassis locking "Disconnected" position locking / 1 part E46685 By padlocks Standard By keylocks Profalux 1 lock 1 lock + 1 lock with same key profile 2 locks (different key profiles) 1 identical keylock Profalux with the same key: key: random not identified combination key: random identified 215470 combination key: random identified 215471 combination Ronis 1 lock 1 lock + 1 lock with same key profile 2 locks (different key profiles) 1 identical keylock Ronis with the same key : key: random not identified combination key: random identified EL24135 combination key: random identified EL24153 combination key: random identified EL24315 combination Locking kit without locks for Profalux Ronis Castell Kirk Installation manual 33773 33774 33775 Right and left-hand side of chassis (VPECD or VPECG) 33172 Installation manual 47104 Racking interlock (VPOC) 33788 Installation manual 47104 33173 33174 33175 33776 33777 33778 33189 33190 33191 33192 33769 33770 33771 33772 47104 E46464 Door interlock / 1 part E46465 Racking interlock / 1 part Breaker mismatch protection / 1 part 33767 Installation manual 47104 E46456 Breaker mismatch protection (VDC) Chassis accessories Auxiliary terminal shield (CB) / 1 part E46698 Terminal shield 3P 4P Installation manual 33763 33764 47104 Safety shutters + locking / 1 part E46699 Safety shutters (VO) 3P 4P Installation manual Nota : the locking of safety shutters is integrated. 33765 33766 47104 134 see your best prices of Merlin Gerin Air Circuit Breakers (ACB) Masterpact NT & NW and other products at www.cyberallgroup.com/SchneiderElectric Catalogue numbers: spare parts Masterpact NT Clusters 0 E95538 Clusters Grease for disconnecting contact clusters (1 kg) 1 disconnecting contact cluster for chassis (see table below) 1 part 54122 33166 Table : number of clusters required for the different chassis models Chassis rating (A) 630 800 1000 1250 1600 Nota : Masterpact NT 3P 4P 12 18 12 18 12 18 12 18 18 24 the minimum order is 6 parts. Racking handle / 1 part 47098 E95561 Racking handle 135 see your best prices of Merlin Gerin Air Circuit Breakers (ACB) Masterpact NT & NW and other products at www.cyberallgroup.com/SchneiderElectric Catalogue numbers: spare parts Masterpact NT Circuit breaker locking and accessories 0 (*) Installation manual must be ordered separatly, it is not supply with the component Circuit breaker locking Pushbutton locking device / 1 part 33897 Installation manual 47103 E46666 By padlocks OFF position locking / 1 part By padlocks + BPFE support E46701 47514 By keylocks + BPFE support Profalux 1 lock 1 lock + 1 lock with same key profile 1 identical keylock Profalux with the same key: key: random not identified combination key: random identified 215470 combination key: random identified 215471 combination Ronis 1 lock 1 lock + 1 lock with same key profile 1 identical keylock Ronis with the same key : key: random not identified combination key: random identified EL24135 combination key: random identified EL24153 combination key: random identified EL24315 combination Locking kit without locks for Profalux Ronis Kirk Castell Installation manual 47519 47520 33173 33174 33175 47521 47522 33189 33190 33191 33192 47515 47516 47517 47518 47103 Other circuit breaker accessories Mechanical operation counter / 1 part 33895 Installation manual 47103 E46667 Operation counter CDM E46670 E46669 E46668 Escutcheon and accessories / 1 part EscutcheonCoverBlanking plate Escutcheon Transparent cover (IP 54) Escutcheon blanking plate Fixed 33718 Installation manual Drawout 33857 33859 33858 47103 Front cover (3P / 4P) / 1 part 47094 Installation manual 47103 E95558 Front cover Spring charging handle / 1 part 47092 Installation manual 47103 E95559 Spring charging handle E95560 Arc chute for Masterpact NT / 1 part Type H1 Type L1 Installation manual 3P 3 x 47095 3 x 47096 4P 4 x 47095 4 x 47096 47103 136 see your best prices of Merlin Gerin Air Circuit Breakers (ACB) Masterpact NT & NW and other products at www.cyberallgroup.com/SchneiderElectric Catalogue numbers: spare parts Masterpact NT Mechanical interlocking for source changeover 0 Mechanical interlocking for source changeover E47760 Interlocking using connecting rods Complete assembly with 2 adaptation fixtures + rods 2 Masterpact NT fixed devices 2 Masterpact NT drawout devices Nota : the installation manual is enclosed. 33912 33913 Choose 2 adaptation fixtures (1 for each breaker) + 1 set of cables 1 adaptation fixture for Masterpact NT fixed devices 1 adaptation fixture for Masterpact NT drawout devices 1 set of 2 cables (1) Can be used with any combination of NT or NW, fixed or drawout devices. 33200 33201 33209 Interlocking using cables (1) E70742 Cable-type door interlock 1 complete assembly for Masterpact NT fixed devices 1 complete assembly for Masterpact NT drawout devices Nota : the installation manual is enclosed. 33920 33921 137 see your best prices of Merlin Gerin Air Circuit Breakers (ACB) Masterpact NT & NW and other products at www.cyberallgroup.com/SchneiderElectric Catalogue numbers: spare parts Masterpact NT Indication contacts 0 (*) Installation manual must be ordered separatly, it is not supply with the component Indication contacts E46463 ON/OFF indication contacts (OF) / 1 part Changeover contacts (6 A - 240 V) 1 low-level OF to replace 1 standard OF (4 max.) Wiring For fixed circuit breaker For drawout circuit breaker Installation manual 47076 47077 47074 33098 47103 E47758 "Fault trip" indication contacts (SDE) / 1 part 1 additional SDE (5 A - 240 V) 1 additional low-level SDE Wiring For fixed circuit breaker For drawout circuit breaker Installation manual 47078 47079 47074 33098 47103 E46664 "Ready to close" contact (1 max.) / 1 part 1 changeover contact (5 A - 240 V) 1 low-level changeover contact Wiring For fixed circuit breaker For drawout circuit breaker Installation manual PF 47080 47081 47074 33098 47103 E46439 Electrical closing pushbutton / 1 part 1 pushbutton BPFE 47512 Installation manual 47103 E46661 Carriage switches (connected / disconnected / test position) / 1 part Changeover contacts (6A - 240 V) 1 connected position contact (3 max.) 1 test position contact (1 max.) 1 disconnected position contact (2 max.) And/or low-level changeover contacts 1 connected position contact (3 max.) 1 test position contact (1 max.) 1 disconnected position contact (2 max.) 33170 33170 33170 33171 33171 33171 E95171 Auxiliary terminals for chassis alone 3 wire terminal (1 part), terminal block (1 part) Jumpers (10 parts) Installation manual 33098 47900 47104 138 see your best prices of Merlin Gerin Air Circuit Breakers (ACB) Masterpact NT & NW and other products at www.cyberallgroup.com/SchneiderElectric Catalogue numbers: spare parts Masterpact NT Instructions 0 (*) Installation manual must be ordered separatly, it is not supply with the component Instructions Chassis accessories Circuit breaker accessories Fixed and drawout circuit breaker Micrologic user manual 20 / 50 (French) 20 / 50 (English) 2A / 7A (French) 2A / 7A (English) 5P / 7P (French) 5P / 7P (English) 5H / 7H (French) 5H / 7H (English) NT user manual French English Modbus communication notice for manual Micrologic accessories replacement guide 47104 47103 47102 33076 33077 33079 33080 33082 33083 33085 33086 47106 47107 33088 33075 139 see your best prices of Merlin Gerin Air Circuit Breakers (ACB) Masterpact NT & NW and other products at www.cyberallgroup.com/SchneiderElectric Catalogue numbers: spare parts Masterpact NW Connection 0 (*) Installation manual must be ordered separatly, it is not supply with the component Connection 3P 4P Top Top 47990 47992 47991 47993 Bottom Bottom 47932 47942 47933 47943 Fixed circuit breakers E95533 E95557 Front connection / Replacement kit (3 or 4 parts) 800/1600 A 2000/3200 A 800/1600 A 2000/3200 A E46446 E46445 Installation manual Rear connection (vertical or horizontal mounting) / Replacement kit (3 or 4 parts) 800/2000 A Vertical Horizontal 2500/3200 A Vertical Horizontal Vertical mounting 4000 A Vertical Horizontal 4000b/5000 A Vertical Horizontal Horizontal mounting 6300 A Vertical Installation manual 47950 47964 47964 47966 47966 47968 47970 2x 47966 2x 47966 2x 47968 47950 47965 47965 47967 47967 47969 47971 2x 47967 2x 47967 2x 47969 47960 47962 47961 47963 Drawout circuit breakers E46450 Front connection / Replacement kit (3 or 4 parts) 800/1600 A 2000/3200 A Top or bottom Top or bottom Installation manual Rear connection (vertical or horizontal mounting) / Replacement kit (3 or 4 parts) 800/2000 A types N1/H1/H2 Vertical 800/1600 A types H3/L1 Horizontal 2500/3200 A types H1/H2 Vertical 2000/3200 A types H3/L1 Horizontal Vertical mounting 4000 A Vertical Horizontal 4000b/5000 A Vertical Horizontal Horizontal mounting 6300 A Vertical Installation manual 47950 47965 47965 47967 47967 47969 47971 2x 47967 2x 47967 2x 47969 3P 4P 1600 A 2000/3200 A 48464 48465 48466 48467 Installation manual 47950 E46446 E46445 47964 47964 47966 47966 47968 47970 2x 47966 2x 47966 2x 47968 47950 Connection accessories E46889 Disconnectable front-connection adapter for fixed circuit breaker (3 or 4 parts) E46428 Interphase barriers / Replacement kit (3 parts) For fixed rear-connected circuit breaker For drawout rear-connected circuit breaker 48599 48600 Installation manual 47950 48599 48600 140 see your best prices of Merlin Gerin Air Circuit Breakers (ACB) Masterpact NT & NW and other products at www.cyberallgroup.com/SchneiderElectric Catalogue numbers: spare parts Masterpact NW Micrologic control unit, communication option 0 (*) Installation manual must be ordered separatly, it is not supply with the component Replacement parts for Micrologic control units Long-time rating plug (limits setting range for higher accuracy) / 1 part E46674 Standard Low-setting option High-setting option Without long-time protection Installation manual 0.4 at 1 x Ir 0.4 at 0.8 x Ir 0.8 at 1 x Ir off 33542 33543 33544 33545 33075 Battery + cover E95540 Battery (1 part) Cover (1 part) For Micrologic A For Micrologic P and H 33593 33592 47067 menu Installation manual 33075 Modbus COM Digipact COM 6 wires terminal drawout (1 part) 6 wires terminal fixed (1 part) 33852 33855 47850 47075 Installation manual 33088 Communication option E95541 Chassis External sensors E46671 External sensor for earth-fault protection (TCE) / 1 part Sensor rating 400/2000 A 1000/4000 A 4000/6300 A 34035 34036 48182 33579 48891 Rectangular sensor for earth-leakage protection + Vigi cable / 1 part 280 mm x 115 mm 470 mm x 160 mm 33573 33574 E46672 E46671 Source ground return (SGR) earth-fault protection / 1 part External sensor (SGR) MDGF summing module Vigi cable or external voltage cable / 1 part Vigi cable or external voltage cable 47090 E59661 External power supply module / 1 part 24-30 V DC 48-60 V DC 100-125 V DC 110-130 V AC 200-240 V AC 380-415 V AC 54440 54441 54442 54443 54444 54445 24 V DC 54446 Battery module / 1 part 1 battery E59554 Test equipments / 1 part Mini test kit Portable test kit Wiring kit or mini test kit or portable test kit 2 pin test cable 33594 33595 33590 S48908 (*) (*) Consult us. 141 see your best prices of Merlin Gerin Air Circuit Breakers (ACB) Masterpact NT & NW and other products at www.cyberallgroup.com/SchneiderElectric Catalogue numbers: spare parts Masterpact NW Remote operation 0 (*) Installation manual must be ordered separatly, it is not supply with the component Remote operation Gear motor E95172 MCH (1 part) AC 50/60 Hz E95171 E95169 DC Terminal block (1 part) Fixed. 48 V 100-130 V 200-240 V 250-277 V 380-415 V 440-480 V 24-30 V 48-60 V 100-125 V 200-250 V For fixed circuit breaker For drawout circuit breaker 47889 47893 47894 47895 47896 47897 47888 47889 47890 47891 47074 47849 Drawout. Installation manual 47951 Closing and opening release (XF or MX) Fixed. E95171 E95169 E95170 Standard coil (1 part) AC 50/60 Hz DC 12 V DC 24-30 V AC/DC 48-60 V AC/DC 100-130 V AC/DC 200-250 V AC/DC 277 V AC 380-480 V AC Communicating coil (1 part) AC 50/60 Hz 12 V DC DC 24-30 V AC/DC 48-60 V AC/DC 100-130 V AC/DC 200-250 V AC/DC 277 V AC 380-480 V AC Terminal block (1 part) For fixed circuit breaker For drawout circuit breaker 33658 33659 33660 33661 33662 33663 33664 33032 33033 33034 33035 33036 33037 33038 47074 47849 Installation manual 47951 Undervoltage release (1 part) AC 50/60 Hz 24-30 V DC, 24 V AC DC 48-60 V DC, 48 V AC 100-130 V AC/DC 200-250 V AC/DC 380-480 V AC Terminal block (1 part) For fixed circuit breaker For drawout circuit breaker 33668 33669 33670 33671 33673 47074 47849 Installation manual 47951 Drawout. Fixed. E95171 E95169 E95170 Undervoltage release MN Drawout. MN delay unit E46694 MN delay unit (1 part) R (non-adjustable) AC 50/60 Hz DC Installation manual 48-60 V 100-130 V 200-250 V 380-480 V 33684 33685 Rr (adjustable) 33680 33681 33682 33683 47951 142 see your best prices of Merlin Gerin Air Circuit Breakers (ACB) Masterpact NT & NW and other products at www.cyberallgroup.com/SchneiderElectric Catalogue numbers: spare parts Masterpact NW Chassis locking and accessories 0 (*) Installation manual must be ordered separatly, it is not supply with the component Chassis locking "Disconnected" position locking / 1 part E46451 By padlocks Standard By keylocks Profalux 1 lock 1 lock + 1 lock with same key profile 2 locks (different key profiles) 1 identical keylock Profalux with the same key: key: random not identified combination key: random identified 215470 combination key: random identified 215471 combination Ronis 1 lock 1 lock + 1 lock with same key profile 2 locks (different key profiles) 1 identical keylock Ronis with the same key : key: random not identified combination key: random identified EL24135 combination key: random identified EL24153 combination key: random identified EL24315 combination Locking kit without locks for Profalux, Ronis Castell Kirk Installation manual 48568 48569 48570 Right and left-hand side of chassis (VPECD or VPECG) 47914 Installation manual 47952 5 parts 48582 Installation manual 47952 33173 33174 33175 48572 48573 48574 33189 33190 33191 33192 48564 48565 48566 47952 E46452 Door interlock / 1 part E46453 Racking interlock Breaker mismatch protection / 1 part 33767 Installation manual 47952 E46456 Breaker mismatch protection (VDC) Chassis accessories Auxiliary terminal shield (CB) / 1 part E46458 800/4000 A 4000b/6300 A 3P 4P 3P 4P 48595 48596 48597 48598 47952 3P 4P 3P 4P 48721 48723 48722 48724 47952 Installation manual Safety shutters + locking block / 1 part E46459 800/4000 A 4000b/6300 A Installation manual E46460 Shutter locking block (for replacement) / 1 part 2 parts for 800/4000 A 48591 Installation manual 47952 Earthing kit for chassis 3P 4P 48433 48434 Types for N1/H1/NA/HA Nota : the installation manual is enclosed. 143 see your best prices of Merlin Gerin Air Circuit Breakers (ACB) Masterpact NT & NW and other products at www.cyberallgroup.com/SchneiderElectric Catalogue numbers: spare parts Masterpact NW Clusters 0 (*) Installation manual must be ordered separatly, it is not supply with the component E95538 Clusters Grease for disconnecting contact clusters (1 kg) 1 disconnecting contact cluster for chassis (see table below) (part 1) 54122 33166 Table : number of clusters required for the different chassis models Chassis rating (A) Masterpact NW 3P N1 H1/H2 H3 630 800 6 12 1000 6 12 1250 6 12 1600 12 12 2000 24 2500 24 3200 36 4000 42 4000b 72 5000 72 6300 72 Nota : the minimum order is 6 parts. 24 24 36 42 L1 24 24 24 24 42 Masterpact NW 4P N1 H1/H2 H3 8 8 8 16 16 16 16 16 32 32 48 56 96 96 96 32 32 48 56 L1 32 32 32 32 56 Racking handle 47944 E95561 Racking handle 144 see your best prices of Merlin Gerin Air Circuit Breakers (ACB) Masterpact NT & NW and other products at www.cyberallgroup.com/SchneiderElectric Catalogue numbers: spare parts Masterpact NW Circuit breaker locking and accessories 0 (*) Installation manual must be ordered separatly, it is not supply with the component Circuit breaker locking Pushbutton locking device / 1 part 48536 Installation manual 47951 E46666 By padlocks OFF position locking / 1 part By padlocks / 1 part E46735 48539 By padlocks and keylocks / 1 part Profalux 1 lock 1 lock + 1 lock with same key profile 2 locks (different key profiles) 1 identical keylock Profalux with the same key: key: random not identified combination key: random identified 215470 combination key: random identified 215471 combination Ronis 1 lock 1 lock + 1 lock with same key profile 2 locks (different key profiles) 1 identical keylock Ronis with the same key : key: random not identified combination key: random identified EL24135 combination key: random identified EL24153 combination key: random identified EL24315 combination Locking kit without locks for Profalux, Ronis Kirk Castell Installation manual 48545 48546 48547 33173 33174 33175 48549 48550 48551 33189 33190 33191 33192 48541 48542 48543 47951 Other circuit breaker accessories Mechanical operation counter / 1 part 48535 Installation manual 47951 E46667 Operation counter CDM Escutcheon Cover Fixed 48601 Escutcheon Transparent cover (IP 54) Escutcheon blanking plate E46670 E46669 E46668 Escutcheon and accessories / 1 part Blanking plate Drawout 48603 48604 48605 48605 Installation manual 47951 Front cover (3P / 4P) / 1 part 47939 Installation manual 47951 E95535 Front cover Spring charging handle / 1 part 47940 Installation manual 47951 E95536 Spring charging handle E95537 Arc chute for Masterpact NW / 1 part Type N1 Type H1/H2 (NW08 to NW40) Type H1/H2 (NW40b to NW63) Type H3 Type L1 Type NW DC Installation manual 3x 3x 6x 3x 3x 3x 3P 47935 47935 47936 47936 47937 47934 4x 4x 8x 4x 4x 4x 4P 47935 47935 47936 47936 47937 47934 47951 145 see your best prices of Merlin Gerin Air Circuit Breakers (ACB) Masterpact NT & NW and other products at www.cyberallgroup.com/SchneiderElectric Catalogue numbers: spare parts Masterpact NW Mechanical interlocking for source changeover 0 (*) Installation manual must be ordered separatly, it is not supply with the component Mechanical interlocking for source changeover E47762 Interlocking of 2 devices using connecting rods Complete assembly with 2 adaptation fixtures + rods 2 Masterpact NW fixed devices 2 Masterpact NW drawout devices Can be used with 1 NW fixed + 1 NW drawout. Nota : the installation manual is enclosed. 48612 48612 Interlocking of 2 devices using cables (1) Choose 2 adaptation sets (1 for each device + 1 set of cables) 1 adaptation fixture for Masterpact NW fixed devices 1 adaptation fixture for Masterpact NW drawout devices 1 set of 2 cables (1) Can be used with any combination of NT or NW, fixed or drawout devices. 47926 47926 33209 Interlocking of 3 devices using cables Choose 3 adaptation (inclusing 3 adaptation fixtures + cables) 3 sources, only 1 device closed, fixed or drawout devices 2 sources + 1 coupling, fixed or drawout devices 2 normal + 1 replacement source, fixed or drawout devices 48610 48609 48608 Cable-type door interlock 1 complete assembly for Masterpact NW fixed or drawout device Nota : the installation manual is enclosed. 48614 146 see your best prices of Merlin Gerin Air Circuit Breakers (ACB) Masterpact NT & NW and other products at www.cyberallgroup.com/SchneiderElectric Catalogue numbers: spare parts Masterpact NW Indication contacts 0 (*) Installation manual must be ordered separatly, it is not supply with the component Indication contacts E46689 ON/OFF indication contacts (OF) / 1 part 1 additional block of 4 contacts Wiring For fixed circuit breaker For drawout circuit breaker 47887 47074 47849 Installation manual 47951 "Fault trip" indication contacts (SDE) / 1 part E46691 Changeover contact (SDE) Wiring 6 A - 240 V Low-level For fixed circuit breaker For drawout circuit breaker Installation manual 47915 47916 47074 47849 47951 E46438 "Ready to close" contact (1 max.) / 1 part 1 changeover contact (5 A - 240 V) 1 low-level changeover contact Wiring For fixed circuit breaker For drawout circuit breaker Installation manual PF 47080 47081 47074 47849 47951 E46661 "Connected, disconnected, test position" indication contact (carriage switches) / 1 part Changeover contacts CE, CD, CT 6 A - 240 V Low-level Installation manual 33170 33171 47952 Set of additional actuaters for carriage switches / 1 set 1 set 48560 E46690 Combined closed / connected contacts for use with 1 auxiliary contact / 1 part 1 contact (5 A - 240 V) or 1 low-level contact 48477 48478 Installation manual 47952 E46677 Electrical closing pushbutton / 1 part 1 pushbutton BPFE 48534 Installation manual 47951 Auxiliary terminals for chassis alone 3 wire terminal (1 part) 6 wire terminal (1 part) Jumpers (10 parts) 47849 47850 47900 147 see your best prices of Merlin Gerin Air Circuit Breakers (ACB) Masterpact NT & NW and other products at www.cyberallgroup.com/SchneiderElectric Catalogue numbers: spare parts Masterpact NW Instructions 0 Instructions Chassis accessories Circuit breaker accessories Fixed and drawout circuit breaker User manual NW AC (French) NW AC (English) NW DC (French) NW DC (English) Micrologic user manual 20 / 50 (French) 20 / 50 (English) 2A / 7A (French) 2A / 7A (English) 5P / 7P (French) 5P / 7P (English) 5H / 7H (French) 5H / 7H (English) Modbus communication notice for manual Micrologic accessories replacement guide 47952 47951 47950 47954 47955 47957 47958 33076 33077 33079 33080 33082 33083 33085 33086 33088 33075 148 see your best prices of Merlin Gerin Air Circuit Breakers (ACB) Masterpact NT & NW and other products at www.cyberallgroup.com/SchneiderElectric Masterpact NT and NW order form Order form To indicate your choice, check the applicable square boxes Indication contacts OF - ON/OFF indication contacts Standard 4 OF 6 A-240 V AC (10 A-240 V AC and low-level for NW) Alternate 1 OF low-level for NT Max. 4 qty and enter the appropriate information in the rectangles Additional Circuit breaker or switch-disconnector Masterpact type NT Rating A Sensor rating A Circuit breaker Special circuit breaker Quantity 1 block of 4 OF for NW Max. 2 EF - combined "connected/closed" contacts 1 EF 6 A-240 V AC for NW NW 1 EF low-level for NW qty Max. 8 qty Max. 8 qty N1, H1, H2, H3, L1 SDE - "fault-trip" indication contact Standard 1 SDE 6 A-240 V AC Additional 1 SDE 6 A-240 V AC 1 SDE low level H2 anticorrosion, H10 Programmable contacts 2 M2C contacts 6 M6C contacts Switch-disconnector NA, HA, HF, HA10, ES Carriage switches Low level 6 A-240 V AC Number of poles 3 or 4 CE - "connected" position Max. 3 for NW/NT qty Brand MG CD - "disconnected" position Max. 3 for NW - 2 for NT qty CT - "test" position Max. 3 for NW - 1 for NT qty SD Option: neutral on right side Type of equipment AC - NW actuator for 6 CE - 3 CD - 0 CT additional carriage switches Fixed Remote ON/OFF Drawout without chassis (moving part only) Chassis alone MCH - gear motor V XF - closing voltage release V MX - opening voltage release Earthing switch kit for chassis V PF - "ready to close" contact Low level Micrologic control unit 6 A-240 V AC 2.0 5.0 6.0 7.0 BPFE - electrical closing pushbutton P - power meter 5.0 6.0 7.0 Res - electrical reset option H - harmonic meter 5.0 6.0 7.0 RAR - automatic reset option LR - long-time rating plug qty Remote operation Drawout with chassis A - ammeter 0 Standard 0.4 to 1 Ir Remote tripping MN - undervoltage release Low setting 0.4 to 0.8 Ir R - delay unit (non-adjustable) High setting 0.8 to 1 Ir Res - adjustable delay unit LR OFF 2nd MX - shunt release AD - external power-supply module V V V V Locking BAT - battery module VBP - ON/OFF pushbutton locking (by transparent cover + padlocks) TCE - external sensor (CT) for neutral and residual earth-fault protection TCE - external sensor (CT) for over sized neutral (3P - Micrologic P / H) and residual earth-fault protection OFF position locking: VCPO - by padlocks VSPO - by keylocks TCW - external sensor for SGR protection Rectangular sensor for earth-leakage protection NT (280 x 115 mm) NW (470 x 160 mm) PTE - external voltage connector Communication COM module JBus/ ModBus Digipact Device Chassis Eco COM module ModBus (for XF or MX communicating release) Device Chassis Connection Keyock kit (w/o keylock) Profalux Ronis 1 keylock Profalux Ronis 2 identical keylocks, 1 key Profalux Ronis 2 keylocks, different keys (NW) Profalux Ronis Chassis locking in "disconnected" position: VSPD - by keylocks Keyock kit (w/o keylock) Profalux Castell 1 keylock Profalux Ronis 2 identical keylocks, 1 key Profalux Ronis 2 keylocks, different keys Profalux Ronis Optional connected/disconnected/test position lock VPEC - door interlock On right-hand side chassis Horizontal Top Bottom Vertical Top Bottom VPOC - racking interlock Front Top Bottom IPA - cable-type door interlock Vertical-connection adapters NT - FC fixed, draw. VDC - mismatch protection Cable-lug adapters NT - FC fixed, draw. VIVC - shutter position indication and locking for NW Arc chute screen NT - FC fixed IBPO - racking interlock between crank and OFF pushbutton for NW Interphase barriers NT, NW fixed, drawout DAE - automatic spring discharge before breaker removal for NW Spreaders NT fixed, drawout Disconnectable front connection adapter Lugs for 240v or 300v cables NW fixed NT fixed, drawout Micrologic control unit functions: 2.0 : basic protection (long time + inst.) 5.0 : selective protection (long time + short time + inst.) 6.0 : selective + earth-fault protection (long time + short time + inst. + earth-fault) 7.0 : selective + earth-leakage protection (long time + short time + inst. + earth-leakage) Ronis Kirk On left-hand side chassis Accessories VO - safety shutters on chassis for NT and NW CDM - mechanical operation counter NT, NW CB - auxiliary terminal shield for chassis NT, NW CC - arc chute cover for fixed NT CDP - escutcheon NT, NW CP - transparent cover for escutcheon NT, NW OP - blanking plate for escutcheon NT, NW Brackets for mounting NW fixed On backplates Test kits Mini test kit Portable test kit see your best prices of Merlin Gerin Air Circuit Breakers (ACB) Masterpact NT & NW and other products at www.cyberallgroup.com/SchneiderElectric