Download SL AUTO - I.c.f.

Transcript
PAGE 8
PAGE 1
GUIDE DE DEPANNAGE
SCHEMA DE PRINCIPE
SECHE LINGE
CARTE ELECTRONIQUE DE PUISSANCE
M/AT
SL AUTO
CONDENSEUR
PH
BL/VI
AP
N
BL/OR
SEC.PORTE
REF.2/10458/D
TC2
OR
CE SECHE LINGE A PROGRAMMATION ELECTRONIQUE EST EQUIPE D'UN
PROGRAMME DIAGNOSTIC QUI PERMET DE VOUS AIDER DANS LA RECHERCHE DE PANNE
TC4
TC5
BAC PLEIN
VIOL
IMPORTANT
CON.6V
TC6
CON.6V
CARTE ELECTRONIQUE D'ACCES
PRES.COND
VIOL
BE/CL
R2:150°
AVANT D'EFFECTUER CE PROGRAMME ASSUREZ-VOUS QUE:
J2
MA/NR
1200W
FUS.
-LE TAMBOUR SOIT VIDE DE LINGE
-LE FILTRE SOIT PROPRE (PAS DE PELUCHE) ATTENTION NE PAS PASSER SOUS L'EAU
VE/F
1000W
R1:140°
-LE CONDENSEUR DOIT ETRE PROPRE
CON.4V
BE/F
KL1
MAR
MOTEUR PANIER
ATTENTION
CD
NOIR
VE/CL
CE PROGRAMME EST CONSTITUE DE 2 PHASES
CON.3V
MOTEUR VENTILATEUR
.
CD
ROUG
PHASE 1
(PAGES 2/3)-PERMET LE CONTROLE DE LA FONCTIONNALITE DE LA CARTE D'ACCES
(CONTROLE DES VOTANTS ET DES TOUCHES)
LES ETAPES B-C-D-E SONT INDEPENDANTES LES UNES DES AUTRES
ELLES PEUVENT ETRE REALISEES DANS UN ORDRE INDIFFERENT
L'ETAPE F PERMET DE VERIFIER SI TOUTES LES ETAPES ONT ETE REALISEES
PHASE 2
(PAGE 4/5)-PERMET LE CONTROLE DE LA FONCTIONNALITE DES COMPOSANTS:
CLAPET CAPTEUR HUMIDISTANCE
ROUG
ART POSITIONNE
GR
GR
J6
CON.4V
CON.2V
CON.4V
CAPTEUR HYGROCAPT
MINIRUPTEUR DE PORTE
CAPTEUR HYGROCAPT
MOTEUR SENS +
MOTOVENTILATEUR
CHAUFFAGE PLEINE PUISSANCE ET MOTEUR SENS COMMANDE CLAPET CAPTEUR HYGROCAPT
ARRET POSITIONNE
PAGE 2
LEGENDE
PHASE 1
VOYANT ALLUME
CONTROLE CARTE D'ACCES
VOYANT CLIGNOTANT
CONTROLE MANUEL DES BOUTONS ET DES VOYANTS
ENTREE EN AUTOTEST
INDIQUE LES VOYANTS A
VERIFIER
ACTIONS MANUELLES
FONCTIONS/SECHE LINGE
VISUALISATION CARTE
-APPUI SUR MARCHE-ARRET.
APPUI SIMULTANNE SUR:
VOUS ETES RENTRE DANS
SI DEFAUT AFFICHEUR VERIFIER:
LE PROGRAMME CONTROLE
CLIGNOTEMENT DE L'AFFICHEUR
3 FOIS SUR TOUCHE.
MA/AT
DIAGNOSTIC
SI CLIGNOTEMENT AFFICHEUR= OK
1
TOUCHE. 2
A
PAGE 3
PHASE 1
VOYANT ETEINT
3 (en - de 5s)
-L'ALIMENTATION(TENSION SECTEUR)
LE TAMBOUR TOURNE EN SENS +
SIGNAL SONORE (3 BIPS)
-MARCHE/ARRET
-LIAISON CARTE PUIS./CARTE D'ACCES
Si NON
1
3
2
CHANGER CARTE D'ACCES
SI LES 3 VOYANTS INDIQUES ALLUMEES =OK
Si NON
CHANGER CARTE D'ACCES
B
APPUYER SUR TOUCHE.
ALLUMAGE DES VOYANTS L1-L2-L3
4
(LE TAMBOUR TOURNE EN SENS +)
4
SI LES 2 VOYANTS INDIQUES ALLUMEES =OK
Si NON
CHANGER CARTE D'ACCES
C
APPUYER SUR TOUCHE.
ALLUMAGE DES VOYANTS L4-L10
5
(LE TAMBOUR TOURNE EN SENS +)
5
SI LES 2 VOYANTS INDIQUES ALLUMEES =OK
Si NON
CHANGER CARTE D'ACCES
D
APPUYER SUR TOUCHE.
(LE TAMBOUR TOURNE EN SENS +)
ALLUMAGE DES VOYANTS L5-L11
6
6
SI LES 3 VOYANTS INDIQUES ALLUMEES =OK
Si NON
CHANGER CARTE D'ACCES
E
APPUYER SUR TOUCHE.
(LE TAMBOUR TOURNE EN SENS +)
ALLUMAGE DES VOYANTS L12-L13-L14
7
7
APPUYER 1 FOIS SUR TOUCHE
5
(LES PHASES B-C-D-E ONT ETE TOUTES
REALISEES)
F
OU
OU
(SI VOUS VOULEZ SHUNTER LES PHASES B-C-D-E)
5
APPUI 3 FOIS EN - DE 2S SUR
CLIGNOTEMENT DE L'AFFICHEUR
ALLUMAGE FIXE VOYANT L4
5
CLIGNOTEMENT DE L'AFFICHEUR
CLIGNOTEMENT VOYANT L4
(LE TAMBOUR TOURNE EN SENS +)
L4
PAGE 4
PHASE 2
ACTIONS MANUELLES
A
G
VISUALISATION CARTE
EXTINCTION DES VOYANTS ET AFFICHEUR
A
FONCTIONS
DIAGNOSTIC
MINIRUPTEUR SEC.PORTE
ARRET DU MOTEUR SENS +
OUVRIR LE COUVERCLE
SI AFFICHEUR INDIQUE'11'=CAPTEUR OK
SI AFFICHEUR INDIQUE '00'ou'10'ou '01'VERIFIER:
B
-LIAISON 4V/4V CAPTEUR /CARTE PUIS.
SI NON
B
FERMER LE COUVERCLE
AFFICHAGE A '11'DE L'AFFICHEUR
CONTROLE CAPTEUR HYGROCAPT
CHANGER CAPTEUR HYGROCAPT
H
SI DEFAUT CAPTEUR EN PHASE'H'
ARRET MOTEUR ET CHAUFFAGE
AFFICHAGE A '2'DE L'AFFICHEUR
I
APPUYER SUR
CONTROLE MOTEUR SENS +
3
CONTROLE PUISSANCE 1200W
3
SI DEFAUT CAPTEUR EN PHASE'H'
ARRET VENTILATEUR
AFFICHAGE A '3'DE L'AFFICHEUR
J
APPUYER SUR
CONTROLE VENTILATEUR
3
->BLOCAGE DU PROG.DIAGNOSTIC AVEC AFF A '2'
SI DEFAUT CAPTEUR EN PHASE'H'
SI DEFAUT MOTEUR VERIFIER:
-LIAISON MOTEUR /CARTE PUIS.
-CONDENSATEUR
-MOTEUR
SI DEFAUT PUIS.1200W VERIFIER:
-LIAISON ELEM.CHAUFFANT/CARTE PUIS.
-THERMOSTATS 1/2 POUCES
-ELEMENT CHAUFFANT (FUS.THERM)
SI NON
CHANGER CARTE DE PUISSANCE
->BLOCAGE DU PROG.DIAGNOSTIC AVEC AFF A '3'
SI DEFAUT CAPTEUR EN PHASE'H'
SI DEFAUT VENTILATEUR VERIFIER:
-LIAISON VENTILATEUR /CARTE PUIS.
-CONDENSATEUR
- MOTEUR VENTILATEUR
SI NON
CHANGER CARTE DE PUISSANCE
3
SI DEFAUT BOBINE CAPTEUR
ARRET MOTEUR ET CHAUFFAGE
CONTROLE BOBINE CLAPET CAPTEUR
APPUYER SUR
CONTROLE MOTEUR SENS -
3
CONTROLE CHAUFFAGE MAXI
3
AFFICHAGE A '5'DE L'AFFICHEUR
->BLOCAGE DU PROG.DIAGNOSTIC
VERIFIER:
AFFICHAGE A '14'DE L'AFFICHEUR
K
SI AFFICHEUR INDIQUE'14'=CAPTEUR OK
SI AFFICHEUR INDIQUE '04' :
SI DEFAUT CAPTEUR PHASE K
ARRET MOTEUR
-LIAISON BOBINE/CARTE DE PUIS.
SI NON
CHANGER CAPTEUR HYGROCAPT
SI DEFAUT CHAUFFAGE VERIFIER:
-LIAISON ELEM.CHAUFFANT/CARTE PUIS.
-THERMOSTATS 1/2 POUCES
-ELEMENT CHAUFFANT (FUS.THERM)
SI NON
CHANGER CARTE DE PUISSANCE
->BLOCAGE DU PROG.DIAGNOSTIC AVEC AFF A '5'
SI DEFAUT CAPTEUR EN PHASE'K'
PUIS
L
AFFICHAGE A 'AP'CLIGNOTANT DE L'AFFICHEUR
APPUYER SUR
3
EXTINCTION DE TOUS LES VOYANTS
APPUYER SUR 1 MARCHE/ARRET
1
CONTROLE PHASE D'ARRET POSITIONNE
(ARRET PANIER EN POSITION HAUTE)
L'AFFICHEUR RESTE A '5' CLIGNOTANT)
3
M
PUIS
AFFICHAGE A 'AP'FIXE DE L'AFFICHEUR
(NOTA:POUR LES SL NON EQUIPES DE L'OPTION
SORTIE DU PROGRAMME CONTROLE
SI DEFAUT ARRET POSITIONNE VERIFIER:
-LIAISON ARRT POSIT/CARTE PUIS.
-PRESENCE AIMANT
-CAPTEUR ARRET POSITIONNE
SI NON
CHANGER CARTE DE PUISSANCE
PAGE 6
PAGE 7
16
17
GR
J8
J7
VCC
HR
GND
CMT2
J4
CMT1
COM
NC
LED3
LED1
LED2
J2
SCL
SDA
MUX
NC
NEUTR
J1
OPT2
OPT1
COM
J3
CARTE D'ACCES
START
MA/AT
COM
CARTE DE PUISSANCE
CTN
J6
GR
DOSSERET
SECT
SCHEMA DE CABLAGE
BL/VI
BL/VI
SAV
57X1511
SL AUTO CD
VE/CL
ROUG
ROUG
MAR
NOIR
BE/F
BE/CL
VIOL
VIOL
OR
BL/OR
BL/VI
SEC.PORTE
VE/F
MA/NR
J14
GR
J6
GR
SCL
SDA
N
PH
ARRET POSITIONNE
VE/CL
ROUG
ROUG
MAR
NOIR
BE/F
BE/CL
VIOL
VIOL
OR
BL/OR
BL/VI
VE/F
L
N
L
N
1200W
ELEMENT CHAUFFANT
SOCLE
CAPTEUR HYGROCAPT
BLANC
BLANC
BLANC
BLANC
ROUGE
ROUGE
MARRON
VE/CL
NOIR
BLEU
NOIR
BLEU
COND.8UF
COND.1.5UF
BE/F
MARRON
NOIR
VENTILATEUR
1000W
BAC PLEIN
FUS.
MAR
ROUGE
MOTEUR PANIER
NOIR
VIOL
VIOL
R1
BA
NOIR
MARRON
0R
JAUNE
R2
PRESENCE COND.
BE/CL
VE/F.
(230V-50HZ)
THERMOSTAT
1
2
3
5
6
7
8
9
.
PHASE
TERRE
MAS.PLAQ.
NEUTRE
BLANC
BLANC
BLANC
BLANC
ROUGE
ROUGE
VE/CL
MARRON
BE/F
NOIR
VIOL
BE/CL
VIOL
JAUNE
VE/F
FILTRE AP
BL/OR
BA
THERMOSTAT
2 3
1
MA/NR
BL/OR
ORANGE
MA/NR
CARTE DE PUISSANCE
5 6
7
8 9
10
11 12
13
14 15
10
COMMUN MOTEUR PANIER
11
COMMANDE MOTEUR PANIER SENS +
12
COMMANDE MOTEUR PANIER SENS -
13
COMMANDE BOBINE CLAPET
NEUTRE+SECURITE PORTE
SECURITE PORTE
14
COMMANDE BOBINE CLAPET
SECURITE BAC PLEIN+PRESENCE CONDENSEUR
15
COMMANDE MOTEUR VENTILATEUR
16
CAPTEUR ARRET POSITIONNE
17
CAPTEUR ARRET POSITIONNE
COMMANDE ELEMENT CHAUFFANT 1200W
COMMANDE ELEMENT CHAUFFANT 1000W
PHASE
SECURITE BAC PLEIN+PRESENCE CONDENSEUR
COMMUN ELEMENT CHAUFFANT (1000+1200W)
ATTENTION
LORS DU REMPLACEMENT DE LA CARTE DE PUISSANCE:
-RESPECTER LA CONCORDANCE ENTRE LA COULEUR DES FILS
DU TORON ET LES MARQUAGES INSCRITS SUR LA CARTE
-TIRER SUR LES CONNECTEURS POUR LES DESENFICHER
(NE PAS TIRER PAR LES FILS)
MARQUAGE/CARTE
MA/NR
VE/F
BL/VI
BL/OR
OR
VIOL
BE/CL
BE/F
NOIR
MAR
ROUGE
VE/CL
COULEUR FIL
MARRON/NOIR
VERT/FONCE
BLANC/VIOLET
BLANC/ORANGE
ORANGE
VIOLET
BLEU/CLAIR
BLEU/FONCE
NOIRE
MARRON
ROUGE
VERT/CLAIR