Download SL AUTO - I.c.f.
Transcript
PAGE 8 PAGE 1 GUIDE DE DEPANNAGE SCHEMA DE PRINCIPE SECHE LINGE CARTE ELECTRONIQUE DE PUISSANCE M/AT SL AUTO CONDENSEUR PH BL/VI AP N BL/OR SEC.PORTE REF.2/10458/D TC2 OR CE SECHE LINGE A PROGRAMMATION ELECTRONIQUE EST EQUIPE D'UN PROGRAMME DIAGNOSTIC QUI PERMET DE VOUS AIDER DANS LA RECHERCHE DE PANNE TC4 TC5 BAC PLEIN VIOL IMPORTANT CON.6V TC6 CON.6V CARTE ELECTRONIQUE D'ACCES PRES.COND VIOL BE/CL R2:150° AVANT D'EFFECTUER CE PROGRAMME ASSUREZ-VOUS QUE: J2 MA/NR 1200W FUS. -LE TAMBOUR SOIT VIDE DE LINGE -LE FILTRE SOIT PROPRE (PAS DE PELUCHE) ATTENTION NE PAS PASSER SOUS L'EAU VE/F 1000W R1:140° -LE CONDENSEUR DOIT ETRE PROPRE CON.4V BE/F KL1 MAR MOTEUR PANIER ATTENTION CD NOIR VE/CL CE PROGRAMME EST CONSTITUE DE 2 PHASES CON.3V MOTEUR VENTILATEUR . CD ROUG PHASE 1 (PAGES 2/3)-PERMET LE CONTROLE DE LA FONCTIONNALITE DE LA CARTE D'ACCES (CONTROLE DES VOTANTS ET DES TOUCHES) LES ETAPES B-C-D-E SONT INDEPENDANTES LES UNES DES AUTRES ELLES PEUVENT ETRE REALISEES DANS UN ORDRE INDIFFERENT L'ETAPE F PERMET DE VERIFIER SI TOUTES LES ETAPES ONT ETE REALISEES PHASE 2 (PAGE 4/5)-PERMET LE CONTROLE DE LA FONCTIONNALITE DES COMPOSANTS: CLAPET CAPTEUR HUMIDISTANCE ROUG ART POSITIONNE GR GR J6 CON.4V CON.2V CON.4V CAPTEUR HYGROCAPT MINIRUPTEUR DE PORTE CAPTEUR HYGROCAPT MOTEUR SENS + MOTOVENTILATEUR CHAUFFAGE PLEINE PUISSANCE ET MOTEUR SENS COMMANDE CLAPET CAPTEUR HYGROCAPT ARRET POSITIONNE PAGE 2 LEGENDE PHASE 1 VOYANT ALLUME CONTROLE CARTE D'ACCES VOYANT CLIGNOTANT CONTROLE MANUEL DES BOUTONS ET DES VOYANTS ENTREE EN AUTOTEST INDIQUE LES VOYANTS A VERIFIER ACTIONS MANUELLES FONCTIONS/SECHE LINGE VISUALISATION CARTE -APPUI SUR MARCHE-ARRET. APPUI SIMULTANNE SUR: VOUS ETES RENTRE DANS SI DEFAUT AFFICHEUR VERIFIER: LE PROGRAMME CONTROLE CLIGNOTEMENT DE L'AFFICHEUR 3 FOIS SUR TOUCHE. MA/AT DIAGNOSTIC SI CLIGNOTEMENT AFFICHEUR= OK 1 TOUCHE. 2 A PAGE 3 PHASE 1 VOYANT ETEINT 3 (en - de 5s) -L'ALIMENTATION(TENSION SECTEUR) LE TAMBOUR TOURNE EN SENS + SIGNAL SONORE (3 BIPS) -MARCHE/ARRET -LIAISON CARTE PUIS./CARTE D'ACCES Si NON 1 3 2 CHANGER CARTE D'ACCES SI LES 3 VOYANTS INDIQUES ALLUMEES =OK Si NON CHANGER CARTE D'ACCES B APPUYER SUR TOUCHE. ALLUMAGE DES VOYANTS L1-L2-L3 4 (LE TAMBOUR TOURNE EN SENS +) 4 SI LES 2 VOYANTS INDIQUES ALLUMEES =OK Si NON CHANGER CARTE D'ACCES C APPUYER SUR TOUCHE. ALLUMAGE DES VOYANTS L4-L10 5 (LE TAMBOUR TOURNE EN SENS +) 5 SI LES 2 VOYANTS INDIQUES ALLUMEES =OK Si NON CHANGER CARTE D'ACCES D APPUYER SUR TOUCHE. (LE TAMBOUR TOURNE EN SENS +) ALLUMAGE DES VOYANTS L5-L11 6 6 SI LES 3 VOYANTS INDIQUES ALLUMEES =OK Si NON CHANGER CARTE D'ACCES E APPUYER SUR TOUCHE. (LE TAMBOUR TOURNE EN SENS +) ALLUMAGE DES VOYANTS L12-L13-L14 7 7 APPUYER 1 FOIS SUR TOUCHE 5 (LES PHASES B-C-D-E ONT ETE TOUTES REALISEES) F OU OU (SI VOUS VOULEZ SHUNTER LES PHASES B-C-D-E) 5 APPUI 3 FOIS EN - DE 2S SUR CLIGNOTEMENT DE L'AFFICHEUR ALLUMAGE FIXE VOYANT L4 5 CLIGNOTEMENT DE L'AFFICHEUR CLIGNOTEMENT VOYANT L4 (LE TAMBOUR TOURNE EN SENS +) L4 PAGE 4 PHASE 2 ACTIONS MANUELLES A G VISUALISATION CARTE EXTINCTION DES VOYANTS ET AFFICHEUR A FONCTIONS DIAGNOSTIC MINIRUPTEUR SEC.PORTE ARRET DU MOTEUR SENS + OUVRIR LE COUVERCLE SI AFFICHEUR INDIQUE'11'=CAPTEUR OK SI AFFICHEUR INDIQUE '00'ou'10'ou '01'VERIFIER: B -LIAISON 4V/4V CAPTEUR /CARTE PUIS. SI NON B FERMER LE COUVERCLE AFFICHAGE A '11'DE L'AFFICHEUR CONTROLE CAPTEUR HYGROCAPT CHANGER CAPTEUR HYGROCAPT H SI DEFAUT CAPTEUR EN PHASE'H' ARRET MOTEUR ET CHAUFFAGE AFFICHAGE A '2'DE L'AFFICHEUR I APPUYER SUR CONTROLE MOTEUR SENS + 3 CONTROLE PUISSANCE 1200W 3 SI DEFAUT CAPTEUR EN PHASE'H' ARRET VENTILATEUR AFFICHAGE A '3'DE L'AFFICHEUR J APPUYER SUR CONTROLE VENTILATEUR 3 ->BLOCAGE DU PROG.DIAGNOSTIC AVEC AFF A '2' SI DEFAUT CAPTEUR EN PHASE'H' SI DEFAUT MOTEUR VERIFIER: -LIAISON MOTEUR /CARTE PUIS. -CONDENSATEUR -MOTEUR SI DEFAUT PUIS.1200W VERIFIER: -LIAISON ELEM.CHAUFFANT/CARTE PUIS. -THERMOSTATS 1/2 POUCES -ELEMENT CHAUFFANT (FUS.THERM) SI NON CHANGER CARTE DE PUISSANCE ->BLOCAGE DU PROG.DIAGNOSTIC AVEC AFF A '3' SI DEFAUT CAPTEUR EN PHASE'H' SI DEFAUT VENTILATEUR VERIFIER: -LIAISON VENTILATEUR /CARTE PUIS. -CONDENSATEUR - MOTEUR VENTILATEUR SI NON CHANGER CARTE DE PUISSANCE 3 SI DEFAUT BOBINE CAPTEUR ARRET MOTEUR ET CHAUFFAGE CONTROLE BOBINE CLAPET CAPTEUR APPUYER SUR CONTROLE MOTEUR SENS - 3 CONTROLE CHAUFFAGE MAXI 3 AFFICHAGE A '5'DE L'AFFICHEUR ->BLOCAGE DU PROG.DIAGNOSTIC VERIFIER: AFFICHAGE A '14'DE L'AFFICHEUR K SI AFFICHEUR INDIQUE'14'=CAPTEUR OK SI AFFICHEUR INDIQUE '04' : SI DEFAUT CAPTEUR PHASE K ARRET MOTEUR -LIAISON BOBINE/CARTE DE PUIS. SI NON CHANGER CAPTEUR HYGROCAPT SI DEFAUT CHAUFFAGE VERIFIER: -LIAISON ELEM.CHAUFFANT/CARTE PUIS. -THERMOSTATS 1/2 POUCES -ELEMENT CHAUFFANT (FUS.THERM) SI NON CHANGER CARTE DE PUISSANCE ->BLOCAGE DU PROG.DIAGNOSTIC AVEC AFF A '5' SI DEFAUT CAPTEUR EN PHASE'K' PUIS L AFFICHAGE A 'AP'CLIGNOTANT DE L'AFFICHEUR APPUYER SUR 3 EXTINCTION DE TOUS LES VOYANTS APPUYER SUR 1 MARCHE/ARRET 1 CONTROLE PHASE D'ARRET POSITIONNE (ARRET PANIER EN POSITION HAUTE) L'AFFICHEUR RESTE A '5' CLIGNOTANT) 3 M PUIS AFFICHAGE A 'AP'FIXE DE L'AFFICHEUR (NOTA:POUR LES SL NON EQUIPES DE L'OPTION SORTIE DU PROGRAMME CONTROLE SI DEFAUT ARRET POSITIONNE VERIFIER: -LIAISON ARRT POSIT/CARTE PUIS. -PRESENCE AIMANT -CAPTEUR ARRET POSITIONNE SI NON CHANGER CARTE DE PUISSANCE PAGE 6 PAGE 7 16 17 GR J8 J7 VCC HR GND CMT2 J4 CMT1 COM NC LED3 LED1 LED2 J2 SCL SDA MUX NC NEUTR J1 OPT2 OPT1 COM J3 CARTE D'ACCES START MA/AT COM CARTE DE PUISSANCE CTN J6 GR DOSSERET SECT SCHEMA DE CABLAGE BL/VI BL/VI SAV 57X1511 SL AUTO CD VE/CL ROUG ROUG MAR NOIR BE/F BE/CL VIOL VIOL OR BL/OR BL/VI SEC.PORTE VE/F MA/NR J14 GR J6 GR SCL SDA N PH ARRET POSITIONNE VE/CL ROUG ROUG MAR NOIR BE/F BE/CL VIOL VIOL OR BL/OR BL/VI VE/F L N L N 1200W ELEMENT CHAUFFANT SOCLE CAPTEUR HYGROCAPT BLANC BLANC BLANC BLANC ROUGE ROUGE MARRON VE/CL NOIR BLEU NOIR BLEU COND.8UF COND.1.5UF BE/F MARRON NOIR VENTILATEUR 1000W BAC PLEIN FUS. MAR ROUGE MOTEUR PANIER NOIR VIOL VIOL R1 BA NOIR MARRON 0R JAUNE R2 PRESENCE COND. BE/CL VE/F. (230V-50HZ) THERMOSTAT 1 2 3 5 6 7 8 9 . PHASE TERRE MAS.PLAQ. NEUTRE BLANC BLANC BLANC BLANC ROUGE ROUGE VE/CL MARRON BE/F NOIR VIOL BE/CL VIOL JAUNE VE/F FILTRE AP BL/OR BA THERMOSTAT 2 3 1 MA/NR BL/OR ORANGE MA/NR CARTE DE PUISSANCE 5 6 7 8 9 10 11 12 13 14 15 10 COMMUN MOTEUR PANIER 11 COMMANDE MOTEUR PANIER SENS + 12 COMMANDE MOTEUR PANIER SENS - 13 COMMANDE BOBINE CLAPET NEUTRE+SECURITE PORTE SECURITE PORTE 14 COMMANDE BOBINE CLAPET SECURITE BAC PLEIN+PRESENCE CONDENSEUR 15 COMMANDE MOTEUR VENTILATEUR 16 CAPTEUR ARRET POSITIONNE 17 CAPTEUR ARRET POSITIONNE COMMANDE ELEMENT CHAUFFANT 1200W COMMANDE ELEMENT CHAUFFANT 1000W PHASE SECURITE BAC PLEIN+PRESENCE CONDENSEUR COMMUN ELEMENT CHAUFFANT (1000+1200W) ATTENTION LORS DU REMPLACEMENT DE LA CARTE DE PUISSANCE: -RESPECTER LA CONCORDANCE ENTRE LA COULEUR DES FILS DU TORON ET LES MARQUAGES INSCRITS SUR LA CARTE -TIRER SUR LES CONNECTEURS POUR LES DESENFICHER (NE PAS TIRER PAR LES FILS) MARQUAGE/CARTE MA/NR VE/F BL/VI BL/OR OR VIOL BE/CL BE/F NOIR MAR ROUGE VE/CL COULEUR FIL MARRON/NOIR VERT/FONCE BLANC/VIOLET BLANC/ORANGE ORANGE VIOLET BLEU/CLAIR BLEU/FONCE NOIRE MARRON ROUGE VERT/CLAIR