Download ELECTRA 1000 LP Gas System Assembly and
Transcript
Technical Details The Regulator: Input Pressure: Regulated Delivery Pressure: Guaranteed Flow Rate: Inlet Pipe Fitting: Outlet Pipe Fitting: 524C 0.3 - 16 bars Butane system 28 mbar Propane system 37 mbar 1.5 Kg/h 20 x 1.5M 20 x 1.5M ELECTRA 1000 LP Gas System The 524C regulator is in fact two regulators designed into one unit. The first regulator takes the cylinder pressure (0.3 -16 bars) and reduces it to a maximum of 0.15 bars (150mbars) which then feeds this constant pressure to the second regulator which reduces the operating pressure to its working pressure - see regulator markings. Assembly and Operating INSTRUCTIONS This regulator also has an additional safety requirement by preventing the delivery pressure from exceeding 150 mbar to the appliances in the event of a malfunction. For Propane or Butane, Single and Double Cylinder Systems High Pressure Hose produced and independently tested to BS 3212 – 1991/2 Gaslow Gauge Design: Din EN 562 2.5 per EN 837-1/5(before switch point) Accuracy Class: Pressure Connection: EN837-1 / 7.3.2 6 metre cable with 2.1mm connector Electrical Data: Factory set switches, non-adjustable Gold plated contact Switch Voltage: Maximum 6 volts Switch Current: 6 mA Max. Switch Energy 12.6 uJ Operating Pressures: Butane 0 - 4 bar Propane 0 - 14.5 bar Electra 1000 Receiver Conforms to CE em directives 4 x AAA Alkaline 1.5V battery = 6 volt Gaslow International Ltd Unit 1, Weldon Road, Loughborough, Leicestershire LE11 5RA. Tel: 0845 4000 600 Email: [email protected]