Technical Details
The Regulator:
Input Pressure:
Regulated Delivery Pressure:
Guaranteed Flow Rate:
Inlet Pipe Fitting:
Outlet Pipe Fitting:
524C
0.3 - 16 bars
Butane system 28 mbar
Propane system 37 mbar
1.5 Kg/h
20 x 1.5M
20 x 1.5M
ELECTRA 1000 LP Gas System
The 524C regulator is in fact two regulators designed into
one unit. The first regulator takes the cylinder pressure
(0.3 -16 bars) and reduces it to a maximum of 0.15 bars
(150mbars) which then feeds this constant pressure to the
second regulator which reduces the operating pressure to its
working pressure - see regulator markings.
Assembly and Operating
INSTRUCTIONS
This regulator also has an additional safety requirement by
preventing the delivery pressure from exceeding 150 mbar to
the appliances in the event of a malfunction.
For Propane or Butane,
Single and Double Cylinder Systems
High Pressure Hose produced and independently tested to BS
3212 – 1991/2
Gaslow Gauge
Design:
Din EN 562
2.5 per EN 837-1/5(before switch point)
Accuracy Class:
Pressure Connection: EN837-1 / 7.3.2
6 metre cable with 2.1mm connector
Electrical Data:
Factory set switches, non-adjustable Gold plated contact
Switch Voltage:
Maximum 6 volts
Switch Current:
6 mA
Max. Switch Energy 12.6 uJ
Operating Pressures: Butane
0 - 4 bar
Propane 0 - 14.5 bar
Electra 1000 Receiver
Conforms to CE em directives
4 x AAA Alkaline 1.5V battery = 6 volt
Gaslow International Ltd
Unit 1, Weldon Road,
Loughborough,
Leicestershire LE11 5RA.